OPTICAL FIBER CABLE. August 2017, New Delhi. CM/L-No

Size: px
Start display at page:

Download "OPTICAL FIBER CABLE. August 2017, New Delhi. CM/L-No"

Transcription

1 OPTICAL FIBER CABLE August 2017, New Delhi CM/L-N

2 INDEX Duct Cable Uni tube Cable Multi tube Cable Armred Cable: Uni tube armred cable Single Sheathed Armred cable Duble sheathed armred cable Cable with Glass Rvings Uni tube cable design Single Sheathed cable design Micr Cable Uni tube Design Cable Multi tube Design Cable ADSS Cable Uni tube ADSS cable Single Sheathed ADSS cable Duble Sheath ADSS Cable Ariel Cable Uni tube Ariel Cable Single Sheathed Ariel Cable Hybrid Cables CATV Cables FTTH Cables Drp Cable - Flat Design Drplet Cable Drp Cable Indr Cables Duplex & Simplex Cables Flat Twin Cable Break ut Cable... 12

3 Duct Cable: 1. Uni Tube Cable Over view:- Duct Cable is designed t be pulled int ducts in service ducts f an ptical cable cmmunicatin netwrk. Its nn-metallic characteristic enables it t be installed in an envirnment where there is electrical interference, fr example alngside pwer lines. The cable design is available in uni tube (up t 12 fibers), the design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist. Glass yarn can be added fr extra axial pulling strength and glass yarn r plyamide can be used as prtectin against rdents. Applicatin: Backbne netwrk rutes, Telecmmunicatin and data trunk Secndary distributin Placement in ducts r n cable trays Optins Available HDPE as uter Jacketing Available Fibre ptins: SM (G652B/D, G655 & G657) Custmized designs are available n request GLASSYARN REINFORCEMENT GLASSYARN REINFORCEMENT BUNDLES 2. Multi Tube Cable Cable Cnstructin:- The cable has multiple lse tubes cntaining ptical fibers and jelly. Lse tubes are S-Z stranded arund nn metallic central strength member (FRP). Suitable fr blwing in ducts/ PVC pipes Duct Cable is designed t be pulled int ducts in service ducts f an ptical cable cmmunicatin netwrk. Its nn-metallic characteristic enables it t be installed in an envirnment where there is electrical interference, fr example alngside pwer lines. The cable design is available in unitube (up t 12 fibres), multitube (up t 144 fibres). The design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist. Aramid r glass yarn can be added fr extra axial pulling strength and glass yarn r plyamide can be used as prtectin against rdents Envirnmental cnditins Temperature ranges fr installatin and assembly Operatin temperatures Transprt and stre temperatures (D- Cable uter diameter) GLASS YARNS Optins Available LSZH/HDPE as uter Jacketing Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2, OM3 & Om4) Dry cre cnstructin is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. Higher Cunt Fiber cable designs are available n request. 1 2

4 Armred Cable: 1. Uni Tube Armred Cable Cable Cnstructin :- Lse tube cntaining fibers and jelly is centrally lcated and additinal glass reinfrcements are applied t prvide high tensile strength and cushin lse tube. Armr f crrugated steel tape prvides high crush resistance & tensile strength. Steel wire strength members are embedded in HDPE sheath t prvide extra tensile strength. The crrugated steel tape is c-plymer cated at bth sides. ECCS Tape armring prvide excellent rdent /rugh Terrain prtectin. Over View :- Direct Burial Cable is designed t be placed directly under the grund either by trenching r plughing. The metallic cable is armred with crrugated steel tape that prvides gd prtectin against rdents and allws the cable t retain utstanding flexibility fr easy installatin. The cable design is available in unitube (up t 12 fibers) and Multitude single sheathed/ duble sheathed cnstructin (up t 144 fibers). Optins Available LSZH/PVC/HDPE as uter Jacketing Available. Custmized designs are available n request. Fiber ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & Om3) Dry cre cnstructin (nn jelly) is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. PE SHEATH CORRUGATED STEEL TAPE ARMOURED GLASSYARN REINFORCEMENT STEEL WIRE 2. Single Sheath Armred Cable Over view :- Direct Burial Cable is designed t be placed directly under the grund either by trenching r plughing. The metallic cable is armured with crrugated steel tape that prvides gd prtectin against rdents and allw the cable t retain utstanding flexibility fr easy installatin. The cable design is available in unitube (up t 12 fibres) and multi tube single sheathed/ duble sheathed cnstructin (up t144 fibers ). Envirnmental cnditins Temperature ranges fr installatin and assembly Operatin temperatures Transprt and stre temperatures (D- Cable uter diameter) GLASS YARNS REINFORCEMENT Optins Available LSZH/HDPE as uter Jacketing Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2, & OM3) Dry cre cnstructin is ptinal. The crrugated steel tape is c-plymer cated at bth sides. ECCS Tape armring prvides excellent rdent /rugh terrain prtectin CORRUGATED STEEL TAPE ARMOURED 3 4

5 3. Duble Sheathed Armred Cable Over view :- Direct Burial Cable is designed t be placed directly under the grund either by trenching r plughing. The metallic cable is armred with crrugated steel tape that prvides gd prtectin against rdents and allws the cable t retain utstanding Flexibility fr easy installatin. The cable design is available in unitube (up t 12 fibers) And multi tube single sheathed/ duble sheathed cnstructin (up t 144 fibers ). Cable Cnstructin :- Lse tube cntaining fibres and jelly are stranded arund a central strength member (FRP). Armur f crrugated steel tape prvides the necessary strength required fr direct burial applicatins. ECCS Tape armuring prvides excellent rdent /rugh terrain prtectin. Envirnmental cnditins Temperature ranges fr installatin and assembly Operatin temperatures Transprt and stre temperatures (D- Cable uter diameter) RECOATED INNER SHEATH CORRUGATED STEEL TAPE ARMOUR Cables with Glass Rvings: 1. Uni Tube Cable GLASS ROVING Optins Available LSZH/FRPVC/HDPE as uter Jacketing Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, Om2 & OM3) Dry cre cnstructin is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. Higher Cunt Fiber cable designs are available n request. 2. Multi Tube with Glass Rving Cable Anther ptin fr direct burial installatin is Glass Armured Cable. This cable is armured with glass rving tape that prvides gd prtectin against rdents and allws the cable t retain utstanding flexibility fr easy installatin. PE SHEATHI GLASS ROVING RIP CORD Used mainly in indr /utdr with PE/LSZH sheath fr lng time perfrmance. Envirnmental cnditins Temperature ranges fr installatin and assembly Operatin temperatures Transprt and stre temperatures (D- Cable uter diameter) Optins Available LSZH/FRPVC/HDPE as uter Jacketing Available Custmized designs are available n request. Micr Cable Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, Om2 & OM3) Dry cre cnstructin is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. Multi Tube Cable Multi tube Micr Cable Design Micr cables suitable fr Fibre-T-The Hme (FTTH) applicatins fr the installatin int duct/micr ducts. Extending ptical fibres reach directly t the residence/business is the next lgical step t prvide highspeed bradband services (such as high speed data, delivering vice services, and high quality vide service OUTER SHEATH (NYLON) WATER SWELLABLE YARNS RIP CORD 5 6

6 ADSS Cable 1. Uni Tube ADDS Cable Over View;- Aerial Cable is designed with integral bearer fr installatin n utility ples f an ptical cable cmmunicatin netwrk. The cable design is available in unitube (up t 12 fibers), multitube design- single sheath cnstructin (up t 144 fibres) and multitube design- duble sheath cnstructin (up t 96 fibres) and figure-8 design. The design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist. All Dielectric Self Supprting (ADSS) cable is designed fr installatin n ples with maximum span f 100 meters. It can be supplied with lse and ribbn fiber r bth. The aramide yarn strength member and the radial shape f the sltted cre prfile prvide an effective prtectin against tensin and radial frces applied by the cable fittings. Being cmpletely dielectric, the cable can be installed parallel with pwer lines. Light weight permits larger spans.ideal fr direct installatin n ples and buildings ARAMID YARNS INNER SHEATH (PE) STRENGTH MEMBER (FRP) LOOSE TUBE WITH S 2. Single Sheathed ADSS Cable Optins Available Nyln/HDPE as uter Jacketing Available. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Dry cre cnstructin (nn jelly) is ptinal. Cmpsite f varius types f fibres (SM & MM). Metallic central strength member ptin available. High strength cable cnstructin is available n request. Higher cunt fiber cable designs are available n request Aerial Cable is designed with integral bearer fr installatin n utility ples f an ptical cable cmmunicatin netwrk. The cable design is available in unitube (up t 12fibers), multitube design- single sheath cnstructin (up t 144 fibres) and multitube design- duble sheath cnstructin (up t 96 fibres) and figure-8 design. The design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist. All Dielectric Self Supprting (ADSS) cable is designed fr installatin n ples with maximum span f 100 meters. It can be supplied with lse and ribbn fiber r bth. The aramide yarn strength member and the radial shape f the sltted cre prfile prvide an effective prtectin against tensin and radial frces applied by the cable fittings. Being cmpletely dielectric, the cable can be installed parallel with pwer lines. Cable Cnstructin :- Lse Tube cntaining fibres and jelly is centrally lcated. The strength members (FRP) are embedded in the HDPE sheath. A layer f nn metallic strength member (aramid yarn) between the inner and uter HDPE sheath prvides the extra tensile strengths required fr aerial installatins. Light weight permits larger spans. Ideal fr direct installatin n ples and buildings. ARAMID YARN (FRP) SWELLING YARN WATER SWELLABLE TAPE Optins Available LSZH//HDPE as uter Jacketing available. Custmized designs are available n request. Fiber ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Dry cre cnstructin (nn jelly) is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. Fr hig strength cable cnstructin is available n request. Higher cunt fiber cable designs are available n request. 3. Duble Sheathed ADSS Cable Aerial Cable is designed with integral bearer fr installatin n utility ples f an ptical cable cmmunicatin netwrk.the cable design is available in unitube (up t 12 fibers), multitube design- single sheath cnstructin (up t 144 fibres) and multitube design- duble sheath cnstructin (up t 96 fibres) and figure-8 design. The design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist All Dielectric Self Supprting (ADSS) cable is designed fr installatin n ples with maximum span f 100 meters. It can be supplied with lse tubes The aramide yarn strength member and the radial shape f the sltted cre prfile prvide an effective prtectin against tensin and radial frces applied by the cable fittings. Being cmpletely dielectric, the cable can be installed parallel with pwer lines Envirnmental cnditins Temperature ranges fr installatin and assembly Operatin temperatures Transprt and stre temperatures (D- Cable uter diameter) FlOODING JELLY ARAMID YARN INNER SHEATH (PE) Ariel Cable Optins Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Dry cre cnstructin (nn jelly) is ptinal. Cmpsite f varius types f fibres (SM & MM). Metallic central strength member ptin available. High strength cable cnstructin is available n request. Higher fibre cunt cable designs are available n request. 1. Uni tube Ariel Cable 2. Single Sheathed Ariel Cable Over View :- Smart cre Aerial Cable is designed with integral bearer fr installatin n utility ples f an ptical cable Cmmunicatin netwrk. The cable design is available in unitube (up t 12 fibers), multi tube design single sheath cnstructin (up t 144 fibers) and multi tube design- duble sheath cnstructin (up t 96 fibers) and figure-8 design. The design is lightweight and flexible and able t withstand nrmal installatin frces f strain, crush, bend and twist. All Dielectric Self Supprting (ADSS) cable is designed fr installatin n ples with maximum span f 100 meters. It can be supplied with lse tube fiber. The aramid yarn strength member and the radial shape f the sltted cre prfile prvide an effective prtectin against tensin and radial frcesapplied by the cable fittings. Being cmpletely dielectric, the cable can be installed parallel with pwer lines. Cable Cnstructin :- The lse tubes cntaining fibres and jelly are S-Z stranded arund a central strength member. A bunch f stranded steel wires are sheathed with cre t make the figure-8 cnstructin, ideal fr aerial installatin. Light weight permits larger spans. Ideal fr direct installatin n ples and buildings. MESSENGER WEB WEB STRENGTH MEMBER(FRP) IN TUBE Optins Available HDPE as uter Jacketing Available. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Dry cre cnstructin (nn jelly) is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. High strength cable cnstructin is available n request. Higher cunt fiber cable designs are available n request. 7 8

7 Hybrid Cables Cable Cnstructin :- High perfrmance Optical fibres are placed in gel-filled buffer tubes which are stranded arund a dielectric central member. Water blcking tape is added t eliminate water ingress & migratin. Periphere strength members are included t prvide apprpriate pulling tensin perfrmance. An insulated pair f cpper cnductr is used as ne f the stranding, elements fr pwer transmissins t energies line cmpnents. FTTH Cables 1. Drp Cable - Flat Design suitable fr aerial installatin t the end cnnectivity up t hme LOOSE TUBE WITH STRENGTH MEMBER (FRP) WATER SWELLABLE YARN INSULATED COPPER CONDUCTOR WATER SWELLABLE TAPE Optins Available LSZH/FRPVE as uter Jacketing Available. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Dry cre cnstructin (nn jelly) is ptinal. Rip Crd is ptinal. Cmpsite f varius types f fibers (SM & MM). Metallic central strength member ptin available. High cunt fiber cable designs are available n request. Cable Cnstructin :- Lse tube cntaining the fibres and jelly is prtected by tw FRP rds and sheathed with tugh weather resistant HDPE. Optins Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Cmpsite f varius types f fibres (SM & MM) Metallic strength member ptin available. Higher fibre cunt cable designs are available n request. LOOSE TUBE WITH FIBRE & JELLY SHEATH (PE) CATV Cables 2. FTTH Drp lite Cable Optins Available HDPE as uter Jacketing Available. Suitable fr aerial installatin t the end cnnectivity up t hme Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & Om3) Dry cre cnstructin (nn jelly) is ptinal. Rip Crd is ptinal. Cmpsite f varius types f fibres (SM & MM). Metallic central strength member ptin available. High fibre cunt cable designs are available n request GLASSYARN REINFORCEMENT BUNDLES Cable Cnstructin :- The 2 fibres embedded in LSZH sheath between 2 ARP rds which can be taken ut easily frm the LSZH sheath. This is suitable fr the successful indr installatin in any type f civil structures Optins Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Cmpsite f varius types f fibres (SM & MM) Metallic strength member ptin available. Higher fibre cunt cable designs are available n request. OUTER SHEATH (LSZH) A.R.P. ROD 9 10

8 FTTH Drp Cable 2. Flat Twin Cable Suitable fr aerial installatin t the end cnnectivity up t hme Cable Cnstructin :- Lse tube cntaining fibres and jelly is placed between tw aramid FRP rds. One GFRP rd prvides extra tensile strength fr aerial installatin. This cable is gd fr last mile FTTH cnnectivity using ples. Optins Available Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Cmpsite f varius types f fibres (SM & MM) Metallic strength member ptin available. Higher fibre cunt cable designs are available n request. SHEATH LOOSE TUBE A.R.P. ROD JELLY OPTICAL FIBER Indr cables are flexible, nn-gel filled cable fr use in telecmmunicatin statins fr intercnnectin between the ptical line system and the fiber distributin frame. It is als suitable fr data netwrks. The sheath is made f PVC that has gd tensile strength and tear resistance. The cable can be terminated with a wide variety f cnnectrs. Simplex design is supplied with ne tight buffered fiber (in single-mde and/r multi-mde) whereas Duplex Design is supplied with tw tight buffered fibers, single-mde r multi-mde. Cable Cnstructin :- Aramid Yarn reinfrcement fr ruggedized prtectin. Flame retardant. Easy t strip & terminate. Meets IEC 60794, & Internatinal standards. Optins Available Tight Buffered cating material: Nyln/PVC/LSZH. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Lse tube design als available with Glass Yarns. OUTER SHEATH (LSZH) INNER SIMPLEX SHEATH (LSZH) TIGHT COATED FIBRE (NYLON) STRENGTH MEMBER (ARAMID YARN) Indr Cables 1. Duplex & Simplex Cables Indr cables are flexible, nn-gel filled cable fr use in telecmmunicatin statins fr intercnnectin between the ptical line system and the fiber distributin frame. It is als suitable fr data netwrks. The sheath is made f PVC that has gd tensile strength and tear resistance. The cable can be terminated with a wide variety f cnnectrs. Simplex design is supplied with ne tight buffered fiber (in single-mde and/r multi-mde) whereas Duplex Design is supplied with tw tight buffered fibers, single-mde r multi-mde. Cable Cnstructin :- These tight-buffered cables are designed fr indr inter-equipment cnnectins. The inside cable is used fr installatin thrugh a duct r cnduit r can be placed n ceiling walls. Als suitable fr cmputer data r TV links, hme autmatin system, terminal link and internal cnnectins. High strength gd bending perfrmance, easy t perate and splice. With tight structure, light, weight, small dimensin and high tensile strength, it facilitates flexible installatins. Aramid Yarn reinfrcement fr ruggedized prtectin. Flame retardant. Easy t strip & terminate. Meets IEC 60794, EIA/TIA, ITU-T, EN , RUS & Internatinal standards. Optins Available Tight Buffered cating material: Nyln/PVC/LSZH. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Lse tube design als available with Glass Yarns. OUTER SHEATH (LSZH) STRENGTH MEMBER (ARAMID YARN) TIGHT COATED FIBRE (NYLON) 3. Break Out Cable Indr cables are flexible, nn-gel filled cable fr use in telecmmunicatin statins fr intercnnectin Between the ptical line system and the fiber distributin frame. It is als suitable fr data netwrks. The Sheath is made f PVC that has gd tensile strength and tear resistance. The cable can be terminated with a wide variety f cnnectrs. Simplex design is supplied with ne tight buffered fiber (in single-mde and/r Multi-mde) whereas Duplex Design is supplied with tw tight Buffered fibers, single-mde r multi-mde. Cable Cnstructin :- Simplex cables are stranded arund central strength member and uter sheath is LSZH. Aramid Yarn reinfrcement fr ruggedized prtectin. Flame retardant. Easy t strip & terminate. Meets IEC 60794, & Internatinal standards. Optins Available Tight Buffered cating material: Nyln/PVC. Custmized designs are available n request. Fibre ptins: SM (G652B/D, G655 & G657), MM (OM1, OM2 & OM3) Lse tube design als available with Glass Yarns. OUTER SHEATH (LSZH) E-GLASSYARN SIMPLEX CABLES ARAMID YARN TIGHT BUFFERED FIBRE 11 12

Integrating Global Communications...

Integrating Global Communications... Integrating Global Communications... Redefining Connectivity Index M. P. Birla Group Profile 5 Profile 7 Fibre Optic Cables Central-tube Unarmoured Cable 10 Multi-tube Single Sheath Unarmoured Cable 11

More information

Optical Systems Contents

Optical Systems Contents Optical Systems Optical Systems Contents Distribution Cables C Type Page 3.7 Breakout Cables T Type Page 3.9 Loose Tube Cables Unitube Page 3.14 Multi Loose Tube Page 3.18 Optical Components Pig / Patch

More information

PowerGuide 200 SkyLight

PowerGuide 200 SkyLight All-Dielectric, Self Supprting (ADSS) Aerial Lse Tube Fiber Optic Cable Dry cre design PwerGuide 200 SkyLight Fiber Cunt Tubes Cre Design Outer Diameter [mm] accrding t OFS Generic Specificatin Applicatin

More information

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables

Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables Premise Distribution Cables LSZH Sheath Strength Members 900µm Tight Buffered Fibre Brand-Rex Optical Cables - Universal PDC Tight Buffered Premise Distribution Cables 4.80.00.60.90 22 460 0 2 29 34 640

More information

Ø 1250 * 688 mm 93 kg ± 105m

Ø 1250 * 688 mm 93 kg ± 105m GCDE Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection 05-05-5 v7.0 Ordering Information Belden Part Numbers Fibre Description

More information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits GAAG Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)Y(T) 05-04-9 v4.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GAAG04 GAAG08 GAAG GAAG8 GAAG4 GAAG30 GAAG36

More information

u n a B Optical Cables UNIFLEX CABLES LTD.

u n a B Optical Cables UNIFLEX CABLES LTD. u n a B Optical Cables UNIFLEX CABLES LTD. Established in 1981, UNIFLEX CABLES LIMITED manufactures a variety of top quality cables in India with a factory size of 15,000 sq. mts. in Umergaon (Gujarat).

More information

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction:

Dax DX-S10121 (12F Sin ngle Mode Armoured Fiber Cable -Uni-Tube Design) Introduction: Dax DX-S10121 (12F Single Mode Armoured Fiber Cable -Uni-Tube Design) Introduction: Dax DX-S1012burial installations, providing outstanding mechanical protection and rodent resistance. is a12 core Single

More information

features and benefits

features and benefits features and benefits Fully waterblocked loose tube, gel-free design Medium-density polyethylene jacket Figure-8 cable design Available in 62.5 µm, 50 µm, single-mode and hybrid versions Simple access

More information

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0

ADSS Fiber Optic Cable. DESCRIPTION core, Single-mode/Multi-mode. Version: V2.0 ITEM MODEL NO. ADSS Fiber Optic Cable A-288-XX DESCRIPTION 2-288 core, Single-mode/Multi-mode Overview AOA-ADSS cable is ideal for installation in distribution as well as transmission environments, even

More information

Fibre Optic Indoor/Outdoor Cable

Fibre Optic Indoor/Outdoor Cable Volition TM Fibre Optic Indoor/Outdoor Cable Tough enough to take it. Easy to handle. The Volition Network Solutions Indoor/Outdoor Fibre Optic Cable from 3M includes horizontal and backbone cable with

More information

Models 7008, 7034, 7035, 7035R & 7041 Planar Blind-Mate Connectors, dc to 40.0 GHz

Models 7008, 7034, 7035, 7035R & 7041 Planar Blind-Mate Connectors, dc to 40.0 GHz Mdels 7008, 7034, 7035, 7035R & 7041 Planar Blind-Mate Cnnectrs, dc t 40.0 GHz Threadless Cnnectr System / S pace Saving / L ng Life Features Threadless Cnnectr Mating - This blind-mate cnnectr series

More information

Insertion Loss (db)

Insertion Loss (db) Optical Interleavers Optplex s Optical Interleaver prducts are based n ur patented Step-Phase Interfermeter design. Used as a DeMux (r Mux) device, an ptical interleaver separates (r cmbines) the Even

More information

C&E Mobility Policy (Standard)

C&E Mobility Policy (Standard) C&E Mbility Plicy (Standard) Originated By: DOCUMENT # VERSION: ISSUE DATE: C&E Mbility Prgram Office ATT-CEM-14001 1 5/16/2014 Title: Upladed t VMT: Last Review Date: Next Review Due By: Raycap Equipment

More information

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, Fig 8 Armored, Multi Tube Outdoor, Fig 8 Armored, Multi Tube Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,

More information

RiverSurveyor S5/M9 & HydroSurveyor Second Generation Power & Communications Module (PCM) Jan 23, 2014

RiverSurveyor S5/M9 & HydroSurveyor Second Generation Power & Communications Module (PCM) Jan 23, 2014 SnTek, a Xylem brand 9940 Summers Ridge Rad, San Dieg, CA 92121-3091 USA Telephne (858) 546-8327 Fax (858) 546-8150 E-mail: inquiry@sntek.cm Internet: http://www.sntek.cm RiverSurveyr S5/M9 & HydrSurveyr

More information

C A B L E C A T A L O G

C A B L E C A T A L O G C A B L E C A T A L O G TKH Grup NV (Twentsche Kabel Hlding NV) is ne f the leading cpanies in the wrld in the field f the cables prductin. The beginning f TKH Grup dates fr 190, when TKF specialized

More information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information GORN Central Loose Tube Cables Outdoor A-DQ(ZN)BY Improved Rodent Protection, 000N Permanent Load 05--0 v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GORN0

More information

Xerox 8160/8142 Wide Format Color

Xerox 8160/8142 Wide Format Color PRODUCT RANGE / POSITIONING The Xerx 8142/8160 Slutin Printer is a thermal inkjet printing system intended fr use in a prductin envirnment prducing graphical cntent, including Psters, POP, signage, etc.

More information

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5. GUXW Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection 05--0 v5.0 Ordering Information Belden Part Numbers Fibre Description / count

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

Wireless Bridge Module for DXR2.E

Wireless Bridge Module for DXR2.E Technical Specificatin Sheet Dcument N. A6V11470500 July 31, 2018 Wireless Bridge Mdule fr DXR2.E Descriptin A wireless bridge cnnects tw wired netwrks tgether ver Wi-Fi utilizing a Wireless Access Pint.

More information

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş. Technical Specification Revision/Date:01/02.15 By S.Erol Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSLT41DYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657 A2

More information

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet,

More information

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA NOTE: These installation instructions have been written for

More information

Weather Sensors. LCN Weather Sensors. Perfection. ISSENDORFF KG Magdeburger Str Laatzen/Germany Tel: +49 (0)

Weather Sensors. LCN Weather Sensors. Perfection. ISSENDORFF KG Magdeburger Str Laatzen/Germany Tel: +49 (0) Weather Sensrs C Weather Sensrs 171 ISSEORFF KG Magdeburger Str.3 30880 aatzen/germany Tel: +49 (0)5066 99 80 www.c.eu Weather Sensrs C-WIH Weather Statin with I Rail Indr Unit The weather statin cnsists

More information

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive

Data sheet OpDAT connection cable 2x1 OS2 - bend insensitive Illustrations Principle diagram Page 1/7 Product specification connection cable for direct connector termination with higher robustness cable structure: I-V(ZN)HH2, duplex patch cable with additional outer

More information

Faster. Easier. Better.

Faster. Easier. Better. Faster. Easier. Better. Single-Jacket, All Dielectric Loose Tube Cables Loose Tube Gel-filled buffer tube prevents water migration. All-dielectric strength member. Available as rated cable, thereby eliminating

More information

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length}

Article number: Sheath marking ACE - TKF LTC ADSS 24x SM G.657.A1 (2x12) A-DQ(ZN)2Y {Batch} {Year} {Length} Description 24x SM G.657.A1 (2x12) The Loose Tube Cable All Dielectric Self-Supporting (LTC ADSS) is a metalfree aerial distribution cable, with dry waterblocking and aramid yarns under the outersheath.

More information

Ø560*336mm 4.25 kg 2100 ± 105m

Ø560*336mm 4.25 kg 2100 ± 105m GUMT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)H Standard Rodent Protection 05-0-0 v3.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM

More information

5. Experimental Results

5. Experimental Results 5. xperimental Results Prttype mdels f the duble spherical helix the hemispherical helix studied in Sectins 4.3.2 4.4 were cnstructed measured. Fabricatin f these antennas measurement f their radiatin

More information

August 2015, website version

August 2015, website version August 2015, website versin TCS X/Y Antenna Prduct Line Features Antenna size ranges frm 1.2 meter t 7.6 meters (larger units available) X/Y axis cnfiguratin Transmit/Receive feed technlgies thrugh Ka-band

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

E-Learning, DC drives DCS800 Hardware Options, part 1 Size D1 D4. ABB Group February 2, 2010 Slide 1 DCS800_HARDWARE_OPTIONS_01R0101

E-Learning, DC drives DCS800 Hardware Options, part 1 Size D1 D4. ABB Group February 2, 2010 Slide 1 DCS800_HARDWARE_OPTIONS_01R0101 E-Learning, DC drives DCS800 Hardware Optins, part 1 Size D1 D4 February 2, 2010 Slide 1 Objectives This training mdule cvers: Lcatin fr plug-in ptins Types f plug-in ptins Fiber ptic cnnectin bard DCS800

More information

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads.

These specifications describe requirements for a power distribution unit (PDU) distributing power to sensitive loads. PDI PwerPak 2 Pwer Distributin Unit Guide Specificatins (Revisin 002, 6/1/2017) 1 General 1.1 Summary These specificatins describe requirements fr a pwer distributin unit (PDU) distributing pwer t sensitive

More information

Single-Armored Cables, Fibers

Single-Armored Cables, Fibers Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease

More information

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) V1

USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) V1 USER MANUAL HIGH INTERCEPT LOW NOISE AMPLIFIER (HILNA TM ) V1 PART NUMBERS: HILNA-V1 HILNA-V1-M/F RF, Wireless, and Embedded Systems Engineering NuWaves Engineering 132 Edisn Drive Middletwn, Ohi 45044

More information

15 years of experience

15 years of experience Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since

More information

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev. Page 1 of 5 Scope: The scope of this procedure is to describe how to properly install a cable pulling grip on an Optical Cable Corporation interlocked armor (ILA) and corrugated steel tape (CST) fiber

More information

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers

ALTOS Lite Gel-Free, Single-Jacket, Single-Armored Cables, Fibers Features and Benefits Fully waterblocked loose tube, gel-free design Simple access and no clean up Single-armored construction Provides additional crush and rodent protection High-strength ripcord Ease

More information

Roof Safe Netting CONTENTS

Roof Safe Netting CONTENTS Rf Safe Netting CONTENTS SUMMARY OF FEATURES... 2 TECHNICAL INFORMATION... 2 Prduct Descriptin... 2 Applicatins... 2 Prduct Infrmatin... 2 Handling & Strage... 3 Technical Data... 4 Size Range Available...

More information

GE Multilin 339 Motor Protection Specifications

GE Multilin 339 Motor Protection Specifications GE Multilin 339 Mtr Prtectin Specificatins The mtr prtectin relay shall prvide primary prtectin fr medium vltage mtrs. The relay shall be equipped with the fllwing prtectin functins. Mtr Thermal Overlad

More information

Variable Attenuators (Step & Continuously)

Variable Attenuators (Step & Continuously) Variable Attenuatrs (Step & Cntinuusly) Wide Chice f Attenuatin & Frequency Ranges. High Reliability & Lng Life Rugged Cnstructin & Cnnectrs Rtatinal Stps Included n mst mdels Lw Cst Designs - Mdel 3033

More information

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application (SM 12 Fibers) Product: Single Mode Optical Fiber Cable Customer: Date: Write by: Kevin Zhou / technical engineer International

More information

SVT Tab and Service Visibility Tool Job Aid

SVT Tab and Service Visibility Tool Job Aid Summary This Jb Aid cvers: SVT Tab Overview Service Visibility Tl (SVT) Area Overview SVT Area: Satellite Mdem Status (Frm Mdem) Clumn SVT Area: Satellite Mdem Status (Frm SMTS) Clumn SVT Area: Prvisining

More information

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or

More information

CPC1035NTR. 4 Pin SOP OptoMOS Relay

CPC1035NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Lad Vltage 3 V Lad Current 12 ma Max R ON 3 Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With

More information

Thermoelectric Thermometer sheathed, with a lock nut on a spring, Typ TTP-313, TTP-314, TTP-315

Thermoelectric Thermometer sheathed, with a lock nut on a spring, Typ TTP-313, TTP-314, TTP-315 Thermelectric Thermmeter sheathed, with a lck nut n a spring, Typ TTP-33, TTP-3, TTP-35 Data sheet TTP-33-3-35, Editin 0/A Applicatin Measuring range: -0.. +800 C General machinery and equipment design

More information

CPC1230NTR. 4 Pin SOP OptoMOS Relay

CPC1230NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Lad Vltage 3 V Lad Current 1 ma Max R ON Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With N Snubbing

More information

RIG SOLAR FILM. High quality clear 48 gauge Polymer material \V;th excellent transmission qualities.

RIG SOLAR FILM. High quality clear 48 gauge Polymer material \V;th excellent transmission qualities. ... a. Ul -'" '" c / RIG SOLAR FILM Fr ver 25 years, Thusand Oak Optical has manufactured the mst ppular white lightfilters in the wrld. Nw with the intrductin f the R-G slar film, ur traditin f excellence

More information

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D Product Model: GYFXTY 2~12C Our Ref: No.TS-FT201107-03-64-V1.0 GENERAL 1.1 These optical cables have excellent protection, optical transmission and mechanical

More information

No, Cell C has partnered up with various Fibre Network Operators (FNO) in the market providing fibre on an open access network.

No, Cell C has partnered up with various Fibre Network Operators (FNO) in the market providing fibre on an open access network. C-FIBRE FREQUENTLY ASKED QUESTIONS 1. What is Fibre? Fibre is a next generatin bradband technlgy that intrduces super-fast speeds and a high capacity netwrk with flexibility, reliability and stability

More information

Pre-Installation Preparation Job Aid

Pre-Installation Preparation Job Aid Summary This Jb Aid cvers: ViaSat Installatin Standards Equipment Necessary fr ViaSat Service installatin Installatin Tls Safety: IDU Safety: ODU Safety: Persnal Safety: Wrking Arund Electricity Safety:

More information

XGS2 Chassis Platform

XGS2 Chassis Platform XGS2 Chassis Platfrm Highlights Supprts Ixia applicatins fr perfrmance, functinal, cnfrmance, and security testing Ixia test systems deliver the industry s mst cmprehensive slutins fr the security, perfrmance,

More information

HIROSE ELECTRIC (U.S.A.), INC.

HIROSE ELECTRIC (U.S.A.), INC. HIROSE ELECTRIC (U.S.A.), INC. 2688 WESTHILLS COURT, SIMI VALLEY, CA 93065-6235 TEL (805) 522-7958 FAX (805) 522-327 Creative Links t W Wrld Electrnics www.hirse.cm T: All Hirse Sales Persnnel and Partners

More information

Fiber Optic Outside Plant Cables (4-144 Fibers)

Fiber Optic Outside Plant Cables (4-144 Fibers) Fiber Optic Outside Plant Cables (4-144 ) Central Tube Dielectric Cable 4-12 Fiber Water Blocking Strength Members Multi-Tube Dielectric Cable 24-216 Fiber The number of tubes changes depending on fiber

More information

CPC1025NTR. 4 Pin SOP OptoMOS Relay

CPC1025NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Lad Vltage 4 V Lad Current 12 ma Typ. R ON 2 Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With

More information

Meteorological Satellites (MetSat) Overview of the global network of Meteorological Satellites. Speaker: Markus Dreis (EUMETSAT)

Meteorological Satellites (MetSat) Overview of the global network of Meteorological Satellites. Speaker: Markus Dreis (EUMETSAT) Meterlgical Satellites (MetSat) Overview f the glbal netwrk f Meterlgical Satellites Speaker: Markus Dreis (EUMETSAT) Secnd ITU/WMO Seminar "Use f Radi Spectrum fr Meterlgy: Weather, Water and Climate

More information

CURRENT AND VOLTAGE SENSORS. General Information. Overhead Current and Voltage Monitoring Insulators (CVMI)

CURRENT AND VOLTAGE SENSORS. General Information. Overhead Current and Voltage Monitoring Insulators (CVMI) CURRENT AND VOLTAGE SENSORS General Infrmatin Overhead Current and Vltage Mnitring Insulatrs (CVMI) Many electric utilities are using Distributin Autmatin (DA) fr bth verhead and undergrund systems. DA

More information

Briefing on Discussions Regarding a Master Lease Agreement for the Intelligent Digital Kiosks

Briefing on Discussions Regarding a Master Lease Agreement for the Intelligent Digital Kiosks Briefing n Discussins Regarding a Master Lease Agreement fr the Intelligent Digital Kisks Cmmittee-f-the-Whle September 11, 2018 Nevin Grinnell Vice President Chief Marketing Officer 1 Agenda Backgrund

More information

Installing a Squeak-Free Nascor Floor System

Installing a Squeak-Free Nascor Floor System Nascr s precise manufacturing tlerances deliver a prduct that resists shrinking, warping and twisting the mst cmmn causes f squeaks in flr systems built with dimensinal lumber. Ensuring a squeak-free flr,

More information

CPC1030NTR. 4 Pin SOP OptoMOS Relay

CPC1030NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Lad Vltage 3 V Lad Current 1 ma Max R ON Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With N Snubbing

More information

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3

VSOF-BS403A. Splice Closure for Fiber Optic Cable User Manual Rev.3 Splice Closure for Fiber Optic Cable 1. Introduction 1.1 General VISSEM S BS403A protects fiber optic splicing point in various installation conditions such as aerial, manholes, ducts, wall and direct

More information

JPS Interoperability Solutions SNV-12 Voter Executive Outline

JPS Interoperability Solutions SNV-12 Voter Executive Outline JPS Interperability Slutins SNV-12 Vter Executive Outline December 1, 2017 Prepared by: JPS Interperability Slutins, Inc. 5800 Departure Drive Raleigh, NC 27616 (919) 790-1011 supprt@jpsinterp.cm sales@jpsinterp.cm

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. Order N. : 5323 02 Operating instructins 1 Safety instructins Electrical devices may nly be munted and cnnected by electrically skilled persns. Serius injuries, fire r prperty damage pssible. Please read

More information

Transmission is reliable and safe when antennas are managed by Movicon

Transmission is reliable and safe when antennas are managed by Movicon Transmissin is reliable and safe when antennas are managed by Mvicn Simetel Spa and Sigma Cnsulting have engineered an interesting supervisin system fr mnitring and security f the NATO VLF transceiver

More information

Preparing microwave transport network for the 5G world

Preparing microwave transport network for the 5G world Preparing micrwave transprt netwrk fr the 5G wrld Maris Bugiuks, Ph.D. 18-12-2017 1 Nkia Netwrks 2015 Micrwave technlgy Transmitting infrmatin Micrwave transmissin is the transmissin f infrmatin r energy

More information

FXP611 Flexible PCB Antenna with Cable Application Note

FXP611 Flexible PCB Antenna with Cable Application Note FXP611 Flexible PCB Antenna with Cable Applicatin Nte APN-14-8-001/A/MB Page 1 f 6 1. BASICS A Flexible PCB antenna with cable is a very flexible, lw prfile, highly reliable, and ecnmical slutin widely

More information

Specification for a communicating Panelboard system to monitor, control and maintain LV electrical installations

Specification for a communicating Panelboard system to monitor, control and maintain LV electrical installations Specificatin fr a cmmunicating Panelbard system t mnitr, cntrl and maintain LV electrical installatins A system fr: - Mnitring the prtectin and cntrl devices in an electrical installatin and prviding the

More information

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH

CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH CAT. 5e U/UTP 4x2x24AWG/1 CCA DOUBLE SHEATH FIGURE CONSTRUCTION Inner conductor CCA Φ 0.50±0.01mm Insulation Solid HDPE Φ 0.90±0.05mm Color 1 Blue & White/ Blue 2 Orange & White/ Orange 3 Green & White/

More information

D a i s y M o d e m s

D a i s y M o d e m s D a i s y M d e m s D a i s y - C h a i n i n g Y u r N e t w r k W i t h R a v e n s W i r e l e s s T e c h n l g y Using Raven s secure Daisy radi mdems t access yur data frm arund the wrld, build yur

More information

Puget Sound Company Overview. Purpose of the Project. Solution Overview

Puget Sound Company Overview. Purpose of the Project. Solution Overview Puget Sund Cmpany Overview Puget Sund Energy is Washingtn State s largest and ldest energy utility, serving nearly 1 millin electric custmers and mre than 650,000 natural gas custmers, primarily within

More information

ELECTRIC ROTATIONAL ACTUATOR TYPE ESO-07

ELECTRIC ROTATIONAL ACTUATOR TYPE ESO-07 Versin: March 00 ELECRIC ROAIONAL ACUAOR Y ESO-0 Applied fr drive f the gate valves and channel nn-return gates Fixing cnnectr, accrding t the ISO 0 standard (cnnectrs F r F) Cmpact design and mdular cnstructin

More information

Canadian OSP Copper I-1. Table of Contents

Canadian OSP Copper I-1. Table of Contents Canadian OSP Copper Premises Copper Table of Contents CELFIL BJBB, BJAB, BJMB and BJTB................................. I-2 Canadian ALPETH BHBB, BHAB, BKMB and BKTB.................... I-4 SEALPAP BHBF,

More information

Samples from

Samples from BCI jist hanger. - Backer blck. Nail with 10 ~ 10d nails. Filler blck. Nail with 10 10d nails. Backer blck required where hanger lad exceeds 1000 Ibs. Backer fr hriznal / siding r stucc. --- BCI jist hanger.

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

Datasheet Outside Plant Cable

Datasheet Outside Plant Cable Outside Plant Cable Direct Buried Cable Direct buried cable can be buried directly into the ground in a trench or using a vibratory plow. Except for with great water-blocking and moisture-proof performance,

More information

CPC1135NTR. 4 Pin SOP OptoMOS Relays

CPC1135NTR. 4 Pin SOP OptoMOS Relays 4 Pin SOP OptMOS Relays Units Blcking Vltage V Lad Current 1 ma Max R ON Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With

More information

KELOX room thermostats - KM690D Digital-Standard/ KM690U Digital-Control

KELOX room thermostats - KM690D Digital-Standard/ KM690U Digital-Control KELOX rm thermstats - KM690D Digital-Standard/ KM690U Digital-Cntrl The KELOX rm thermstats are high-quality rm temperature cntrllers fr recrding and cntrlling the required rm temperature fr a maximum

More information

CPC1004NTR. 4 Pin SOP OptoMOS Relay

CPC1004NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Blcking Vltage (DC) V Lad Current (DC) 3 ma Max R ON 4 Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free

More information

FTTH Fiber Optical Cable

FTTH Fiber Optical Cable FTTH Fiber Optical Cable FTTH Drop Cables are designed to connect the fiber access point to the ONT on the home in a FTTH network. It offers an efficient and economical solution for deploying fiber in

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

b. Army Reserve Design Process Submittal Requirements (DPSR) c. USARC G-2/6 IT Design Whitepaper, 2 April 2012 ( ENCLOSURE 1)

b. Army Reserve Design Process Submittal Requirements (DPSR) c. USARC G-2/6 IT Design Whitepaper, 2 April 2012 ( ENCLOSURE 1) CELRL-PM-R April ARCOS BULLITEN - SUBJECT: IT Design. REFERENCE: a. Army Reserve IT Manual, Change b. Army Reserve Design Prcess Submittal Requirements (DPSR) c. USARC G-/ IT Design Whitepaper, April (

More information

A c r o s s t h e S k y l i n e

A c r o s s t h e S k y l i n e A c r s s t h e S k y l i n e D a i s y - C h a i n i n g Y u r N e t w r k W i t h R a v e n s W i r e l e s s T e c h n l g y Using Raven s secure Daisy radi mdems and Skyline System t wirelessly access

More information

Figure 1: View, connection compartment closed

Figure 1: View, connection compartment closed Radi Management Art. N. : 2700AP Operating instructins 1 Safety instructins Electrical equipment may nly be installed and fitted by electrically skilled persns. Serius injuries, fire r prperty damage pssible.

More information

OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY

OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY OPERATOR S MANUAL BOP (M) (D) 100W, 200W, 400W BIPOLAR POWER SUPPLY 100W: BOP 20-5, BOP 50-2, BOP 100-1 200W: BOP 20-10, BOP 36-6, BOP 50-4, BOP 72-3, BOP 100-2, BOP 200-1 400W: BOP 20-20, BOP 36-12, BOP

More information

Pool & Hot Tub Guide

Pool & Hot Tub Guide Pl & Ht Tub Guide PERMIT(S) FOR POOLS/HOT TUBS WITH SIDE WALLS > 24 ***** ALL FEES DUE AT TIME OF APPLICATION ***** Building Permit Applicatin. Be aware f any subdivisin restrictins prir t applicatin.

More information

BENZINGER. obliged to precision BENZINGER PRÄZISIONSMASCHINEN TNI. Precise Fast Compact PRECI CNC-PRECISION- TURNING-MILLING CENTRE

BENZINGER. obliged to precision BENZINGER PRÄZISIONSMASCHINEN TNI. Precise Fast Compact PRECI CNC-PRECISION- TURNING-MILLING CENTRE BENZINGER PRÄZISIONSMASCHINEN BENZINGER bliged t precisin Precise Fast Cmpact TNI CNC-SION- TURNING-MILLING CENTRE Precise Fast Cmpact TNI PreciLine - Everything is abut the custmer s need, cmplete machining

More information

DragonWave Gigabit Solutions. DragonWave Proprietary Information 1

DragonWave Gigabit Solutions. DragonWave Proprietary Information 1 DragnWave Gigabit Slutins DragnWave Prprietary Infrmatin 1 Gigabit Circuit Demand Gd News: Demand fr Gigabit Circuits is increasing! Educatin Business Energy Gvernment Mre Mney! Bad News: Prviding Gigabit

More information

GE Multilin 369 LV & MV Motor Management Relay Specifications

GE Multilin 369 LV & MV Motor Management Relay Specifications GE Multilin 369 LV & MV Mtr Management Relay Specificatins The mtr management relay shall prvide primary prtectin and management t medium vltage mtrs. The relay shall be equipped with the fllwing prtectin

More information

PhotoVu Digital Picture Frame Service & Repair Guide

PhotoVu Digital Picture Frame Service & Repair Guide PhtVu Digital Picture Frame Service & Repair Guide PhtVu, LLC 2450 Central Ave, #G1 Bulder, CO 80301 USA www.phtvu.cm/supprt Versin: 1.0 Table f Cntents Getting Started... 3 Determine Yur Generatin f PhtVu

More information

DynaRound Hatch Guard System Installation Instructions

DynaRound Hatch Guard System Installation Instructions DynaRund Hatch Guard System Installatin Instructins Estimated Installatin Time: Man Crew, 0-90 Minutes The DynaRund Hatch Guard System is designed t prtect all rftp hatch entry and exit pints. This nn-penetrating

More information

CB-030S Circuit Board

CB-030S Circuit Board CB-030S Circuit Bard Designed fr use with the high trque PM486FH (up t 7A) Adjustable acceleratin and deceleratin time (0 t 2.5s) Stable speed peratin Switch fr manual r autmatic recvery f the thermal

More information

LED wdali MC Switch Input Modul Set - User Manual

LED wdali MC Switch Input Modul Set - User Manual LED wli MC Switch Input Mdul Set - User Manual Buttn mdul (Transmitter) 1. Prduct Descriptin Item N.: LC-004-302 Receive mdul (Receiver) The wli MC Switch Input Mdul Set is a cmpact wireless Multi Cntrl

More information

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Small Glass Projection Case. Type SC In Rear-connected Small Glass Case

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Small Glass Projection Case. Type SC In Rear-connected Small Glass Case July, 1991 Supersedes DB 41-765, pages 1-8, dated May, 1987 Mailed t: E, 0, C/41-100A Applicatin The Types SC, SC-1 current relays are suitable fr any applicatin where an instantaneus plunger relay f high

More information

Wins Soft OUR CORPORATE GOAL IS TO CREATE ADDED VALUE FOR CUSTOMERS AND EMPLOYEES, TRUE TO THE MOTTO

Wins Soft OUR CORPORATE GOAL IS TO CREATE ADDED VALUE FOR CUSTOMERS AND EMPLOYEES, TRUE TO THE MOTTO Wins Sft Abut Us : WINS SOFT is ne f the fastest grwing IT Cmpany prviding Textile Slutin t Medium and Large-Scale textile based cmpanies. It was funded with the visin f prducing innvative and affrdable

More information

LINE POWER SUPPLIES Low-Loss Supplies for Line Powered EnOcean Modules

LINE POWER SUPPLIES Low-Loss Supplies for Line Powered EnOcean Modules Lw-Lss Supplies fr Line Pwered EnOcean Mdules A line pwer supply has t ffer the required energy t supply the actuatr electrnic and t supply the EnOcean TCM/RCM radi cntrl mdule. This paper cntains sme

More information

HygroFlex HF4 Humidity Temperature Transmitters. User Guide

HygroFlex HF4 Humidity Temperature Transmitters. User Guide Page 1 f 27 HygrFlex HF4 Humidity Temperature Transmitters User Guide 2009; E-M-HF4-V1_20 Page 2 f 27 Table f cntents 1 Overview... 3 2 Mechanical cnfiguratins and dimensins... 4 2.1 Display and keypad

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Lad with min. 5 kg 405000090 405070090 INSTALLATION INSTRUCTIONS CONTENT: 1. Imprtant safety instructins. 2. Specificatins and main dimensins. 3. Parts included. 4. Installatin. 5. Adjusting the strke

More information

CPC1130NTR. 4 Pin SOP OptoMOS Relay

CPC1130NTR. 4 Pin SOP OptoMOS Relay 4 Pin SOP OptMOS Relay Units Blcking Vltage 3 V Lad Current 12 ma Max R ON 3 Ω Features Small 4 Pin SOP Package Lw Drive Pwer Requirements (TTL/CMOS Cmpatible) N Mving Parts High Reliability Arc-Free With

More information