MEDIUM VOLTAGE. For your projets where the low voltage is limited. 3200V 5500V 6600V Energy distribution

Size: px
Start display at page:

Download "MEDIUM VOLTAGE. For your projets where the low voltage is limited. 3200V 5500V 6600V Energy distribution"

Transcription

1 MEDIUM VOLTAGE For your projets where the low voltage is limited 3200V 5500V 6600V Energy distribution

2 YOUR EXISTING CONSTRAINTS Example 1: FROM LV EXISTING ELECTRICAL SOURCES : Transport the LV to the cabinets LV Cabinet LV Cabinet Long distance LV Source Town Ind. Area Crossing of property LV Cabinet LV Source Is this feasible? Will you find these sources in the vicinity? What will be the cost of large cross-section cable which will carry energy to the course? Will it be easy and cheap to manage the administrative formalities and the authorizations? Example 2: FROM A HV ELECTRICAL SOURCE : Creation of a HV and LV network. Town Ind. Area T T T HV Source HV / LV transformers Is this feasible to transport the HV along the course? What will be the cost? Do you control the deadlines? Isn t it luxurious for a simple lighting?

3 10 km 6 km Building 4 km Training Field YOUR EXISTING CONSTRAINTS EXAMPLE 3: BIG SITE CASE :MILITARY, OIL & GAS, INDUSTRIAL, HARBOR, AIRPORT, AGRICULTURAL FARM... Building Sports Center Electrical Station 4 km Camera Parking Projector (3 x 1000W)

4 YOUR VOLTAGE BECOMES : Medium Voltage This solution brings the autonomy of study, of work and of work management at an undervalued total cost. From only one Low Voltage (400 V) or High Voltage (11 kv - 33 kv) electrical source, we advise you to create a MV which allows the energy distribution along the course on average and long distances (from 2 to 20 km). MV LV or MV Source We study with you and for you all the design of the step-up or step-down cabinet. We are a manufacturer of this kind of systems «MV sources» : 3200 V, 5500 V or 6600 V. This voltage is transported by adapted cable (6kV). Transformers burried closed to the lighting column restore the LV voltage 230 V or 400 V. We produce those transformers, real «step-down mini-station». Those cables and transformers will be installed by your contractor. The MV allows you autonomy with a reduced budget from 15 to 30% but will also bring you the possibility to add other advantages : - To forecast future extensions - To save energy at rest time - The telemanagement by STEP All relative procedures and rules are respected

5 Some Examples Example 1 : ROAD LIGHTING 3200 V single phase network - Length 4500 meters - Electrical source at the begining 150 lamps of 250 W SHP Transformers 3200 V / 230 V LV Cable 2 x 10 mm² 3200 V Single phase 3200 V Cable 1 x mm² Outdoor PTC 400 V Example 2 : ROAD LIGHTING + INTERCHANGE 3200 V single phase network - 3 network output feeders. LV Cable 2 x 10 mm² Transformers 3200 V / 230 V 3 kva 3200 V Single phase 25 to 250 kva Cable 3200 V 1 x mm² Indoor PTM or step-down station 400 V three phase or 20 kv

6 Some Examples Example 3 : MOTORWAY LIGHTING 5500 V three phase network - Length m - Electrical source in the middle 366 lamps 2 x 250 w Transformers 5500 V / 230 V 5 kva Cable LV 2 x 10 mm² 5500 V Three phase Cable 5500 V 3 x 25 mm² Main station 800 kva equipped 20 kv Example 4 : GREAT SITE LIGHTING V three phase network. Site road Cable 5500 V Inner roads 5500 V Three phase Access road 2000 m LV Cable 2 x 10 mm² 4500 m 20 kv three phase Transformers and dimmer 400 kva

7 ROAD LIGHTING INDICATIVE TABLE TO CHOOSE THE TRANSPORTATION VOLTAGE Cross-section of calculated for a drop voltage of : 5% for 950 V network, 3% for 3200 V and 5500 V network. Power rating uniformy spread. For information : In a project, 2 step-up stations can be replaced by one step-down station. In each case, possibility to add an energy saver dimmer : -For the step-up cabinets : the compacto dimmers. -For the step-down stations : THR 550 from160 to 630 kva

8 MATERIAL FOR STATIONS & EQUIPPED STATIONS Simplified cabinet PTS32 Switchboard 5500 V Modular substation PTM Power transformer Compact minisubstation PTC NETWORK TRANSFORMERS Modulobloc TED TER

9 YOU DECIDE TO SAVE ELECTRICAL ENERGY In the electrical station HV / MV or LV/ MV, it is possible and recommended to add a voltage varation/ regulation device. To the hours chosen by the owner, the consumed power will be reduced and will continue to ensure the site safety. «HTI Dimmer» «LV-72 kva Dimmer» «LV Dimmer : Compacto TT» Daily cycle of variation An idea... MV Compacto dimmer TT MV / LV Transformers LV or MV

10 Functions and further services for MV The STEP II is a remote control and (or) monitoring system by power carrier line technology on the MV networks. Avantages : No light on and off each part on request. Goal : To light on and off each part on request. Transformation station Constraint : Station : LV cabinet, cells, transformers circuit breakers GTC Cabinet Control station : GTC Station GTC Station 5500 V Cells Transformers MV Cell On the network Local station MV Network Supplyin g network 120 V V Supply Autonomous or supervised commend Commend and/or checking of LV contactors

11 Remote control / signalling of the network : The STEP II In the station The coupling device allows the order or information transmission from the LV to MV network and inversely. The coupling device The AUGIER module Master On the network The AUGIER module Slave The indoor coupling device The outdoor coupler MCEPT On the network, 2 types of coupling devices - Coupling device installed in the transformer - Coupling device independent of the transformer Equipment Piloting Measures : Voltage Current Checking : for a permanent usage and its telemanagement

12 AUGIER IS CERTIFIED ISO 9001 SINCE With constant improvements, the manufacturer may alter information without prior warning

Communication by power line carrier technology. For medium voltage networks

Communication by power line carrier technology. For medium voltage networks CELLULES STEP II CEP14/15 Communication by power line carrier technology For medium voltage networks STEP II - System Presentation Developped for networks 120 V 6,600 Volts including French standards 950

More information

CELLULES MEDIUM VOLTAGE

CELLULES MEDIUM VOLTAGE CELLULES MEDIUM VOLTAGE CEP14/15 Thoughts on the distribution of electrical energy 950 V 3200 V 5500 V 6600 V 2 CONTENTS GENERAL : The receivers. p. 4 Network transformer in a pit or compact substation.

More information

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011

PRODUCT LEAFLET AUGIER-BOX. Remote Monitoring Unit for Street Lighting /07/2011 PRODUCT LEAFLET AUGIER-BOX Remote Monitoring Unit for Street Lighting 1 60 11432-04/07/2011 Put a TECHNICIAN in each street lighting cabinet, and control them 24H per day! The Augier-Box Programmable Logic

More information

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER. Power Voltage Transformers for Air Insulated Substations THE PROVEN POWER. Introduction Trench Power Voltage Transformers (Power VTs) combine the attributes of an inductive voltage transformer with the

More information

Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List

Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List Manual: Distribution Substation Manual (DSM) Section D: Substation Drawing Revision List Standard Number: HPC-5DA-07-0011-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer

More information

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201 Low Voltage Products Enclosed Third Harmonic Filter and star Enclosed units Brochure S1GB 3_4 1SCC333C21 The Third Harmonic - a Growing Problem Today's electrical networks and plants are under much more

More information

KENYA ELECTRICITY GENERATING COMPANY LTD

KENYA ELECTRICITY GENERATING COMPANY LTD KENYA ELECTRICITY GENERATING COMPANY LTD TENDER No. KGN-HYD-014-2016 TENDER FOR REHABILITATION OF PROTECTION EQUIPMENT FOR MASINGA HYDRO POWER STATION 20/06/2016 ADDENDUM NO. 1 In accordance with the tender

More information

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201 Low Voltage Products Third Harmonic Filter and star System components for assembly and retrofitting Catalogue SGB _ SCCC System components for assembly and retrofitting star, installation in the transformer

More information

MODULOBLOC TRANSFORMERS

MODULOBLOC TRANSFORMERS PRODUCT LEAFLET MODULOBLOC TRANSFORMERS Network Modulobloc Transformer (3200 V - 5500 V - 6600 V from 1 to 160 kva) 1 60 10592-13/06/2014 PRODUCTS PRESENTATION SINGLE-PHASE SETS FOR SINGLE-PHASE NETWORKS

More information

Innovations in Drive Technologies. High-availability, medium-voltage, variable speed drives for pumping and compression

Innovations in Drive Technologies. High-availability, medium-voltage, variable speed drives for pumping and compression Innovations in Drive Technologies High-availability, medium-voltage, variable speed drives for pumping and compression Siemens AG 2015. 2013. All rights reserved. Common MV VSD topologies LCI PWM 3 level

More information

Protection of Electrical Networks. Christophe Prévé

Protection of Electrical Networks. Christophe Prévé Protection of Electrical Networks Christophe Prévé This Page Intentionally Left Blank Protection of Electrical Networks This Page Intentionally Left Blank Protection of Electrical Networks Christophe Prévé

More information

INSTRUMENT TRANSFORMERS. Product Spectrum

INSTRUMENT TRANSFORMERS. Product Spectrum INSTRUMENT TRANSFORMERS Product Spectrum Context The transmission of energy from the generation sites to the places of use is carried out through high voltage electrical lines and substations as interconnecting

More information

WITHDRAWN JULY Manual: Distribution Substation Manual (DSM) Section I: Introduction

WITHDRAWN JULY Manual: Distribution Substation Manual (DSM) Section I: Introduction Manual: Distribution Substation Manual (DSM) Section I: Introduction Standard Number: HPC-5DA-07-0010-2012 Document Control Author Name: Viswa Easwaran Position: Standards Engineer Document Owner Name:

More information

EDS LV ELECTRICAL SERVICE DRAWINGS

EDS LV ELECTRICAL SERVICE DRAWINGS Document Number: EDS 08-2110 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 08-2110 LV ELECTRICAL SERVICE DRAWINGS EPN, LPN, SPN This standard details the drawings for service positions and connection

More information

Onsite Mobile AC High Voltage Test System

Onsite Mobile AC High Voltage Test System TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument

More information

A compact, integrated solution for medium voltage connection, transformer and low voltage distribution

A compact, integrated solution for medium voltage connection, transformer and low voltage distribution Low to medium voltage distribution M2L integrated power distribution system A compact, integrated solution for medium voltage connection, transformer and low voltage distribution Turnkey solution medium

More information

MAJOR ADVANCES IN MV/LV SUBSTATIONS. Th.Grima et JF.Faltermeier. Groupe CAHORS, France SUMMARY

MAJOR ADVANCES IN MV/LV SUBSTATIONS. Th.Grima et JF.Faltermeier. Groupe CAHORS, France SUMMARY MJOR DVNCES IN MV/LV SUSTTIONS Th.Grima et JF.Faltermeier Groupe CHORS, France SUMMRY Improvements on the reliability of the components of the network, combined with a well-considered policy of cost reduction

More information

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström

EH27401 Communication and Control in Electric Power Systems Lecture 2. Lars Nordström EH27401 Communication and Control in Electric Power Systems Lecture 2 Lars Nordström larsn@ics.kth.se 1 Course map 2 Outline 1. Power System Topologies Transmission Grids vs Distribution grids Radial grids

More information

Designed for operation at traffic control points and other places where total 100% inspection is required.

Designed for operation at traffic control points and other places where total 100% inspection is required. Telephone : +44 (01295 756300 Fax : +44 (0)1295 756302 E-Mail : info@wi-ltd.com Website : www.wi-ltd.com WG Occupied Car, Mini-Bus & Van Dual View Scanner System The WG Occupied Car, Mini-Bus & Van Dual

More information

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance

Click to edit Master title style. Click to edit Master title style. Northern Powergrid Asset Recording Guidance Click to edit Master title style Click to edit Master title style Northern Powergrid Asset Recording Guidance Rules for ICP & IDNO Version 1.0 April 2017 Introduction Accurate records for all assets are

More information

VI 3 - i TABLE OF CONTENTS

VI 3 - i TABLE OF CONTENTS VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3

More information

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications: SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument

More information

New Methods to Mitigate Distribution System Harmonics

New Methods to Mitigate Distribution System Harmonics Alberta Power Industry Consortium 214 Power & Energy Innovation Forum New Methods to Mitigate Distribution System Harmonics By Wilsun Xu Power Disturbance & Signaling Research Lab November 5, 214 Outline

More information

WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS

WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS WFPS1 WIND FARM POWER STATION GRID CODE PROVISIONS WFPS1.1 INTRODUCTION 2 WFPS1.2 OBJECTIVE 2 WFPS1.3 SCOPE 3 WFPS1.4 FAULT RIDE THROUGH REQUIREMENTS 4 WFPS1.5 FREQUENCY REQUIREMENTS 5 WFPS1.6 VOLTAGE

More information

ECP COMPACT AND MICRO SUBSTATION COMMISSIONING PROCEDURE

ECP COMPACT AND MICRO SUBSTATION COMMISSIONING PROCEDURE Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE ECP 11-0507 COMPACT AND MICRO SUBSTATION COMMISSIONING PROCEDURE EPN, LPN, SPN This procedure details the testing and commissioning procedures for

More information

Table of Contents. Introduction... 1

Table of Contents. Introduction... 1 Table of Contents Introduction... 1 1 Connection Impact Assessment Initial Review... 2 1.1 Facility Design Overview... 2 1.1.1 Single Line Diagram ( SLD )... 2 1.1.2 Point of Disconnection - Safety...

More information

MV network design & devices selection EXERCISE BOOK

MV network design & devices selection EXERCISE BOOK MV network design & devices selection EXERCISE BOOK EXERCISES 01 - MV substation architectures 02 - MV substation architectures 03 - Industrial C13-200 MV substation 04 - Max. distance between surge arrester

More information

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor. Basis of Design This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor. Background Information A Short Circuit and Coordination

More information

Magtech Voltage Booster MVB

Magtech Voltage Booster MVB Model overview MVB 27.03.08 EG.doc Magtech Voltage Booster Voltage fluctuations caused by unbalanced load in Y-ground grid? Low voltage part of the day due to high load? Quick and profitable solution with

More information

Magtech Voltage Booster MVB

Magtech Voltage Booster MVB Model overview MVB 30.04.09 EG.doc Magtech Voltage Booster Voltage fluctuations caused by unbalanced load in Y-ground grid? Low voltage part of the day due to high load? Quick and profitable solution with

More information

ABB Power Products Service

ABB Power Products Service Raben Naidoo, Technology days, May 21-22th, 2014, Cape Town, South Africa, Enhanced availability of transformers via transformer remote monitoring - TEC ABB Power Products Service Why a session on availability?

More information

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor 500 kva Dry-type Isolation Transformer - 13200V-Delta to 208Y/120V 3PH - NEMA 1/Indoor Part #: MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Page: 1 The MT-DOE16-3P-13200D-500KVA-208Y.120-N1 Dry-type Isolation

More information

How to maximize reliability using an alternative distribution system for critical loads

How to maximize reliability using an alternative distribution system for critical loads White Paper WP024001EN How to maximize reliability using an alternative distribution system for critical loads Executive summary The electric power industry has several different distribution topologies

More information

ELECTRICAL POWER ENGINEERING

ELECTRICAL POWER ENGINEERING Introduction This trainer has been designed to provide students with a fully comprehensive knowledge in Electrical Power Engineering systems. The trainer is composed of a set of modules for the simulation

More information

URBAN MEDIUM VOLTAGE DISTRIBUTION NETWORK WITH CROSS CONNECTION

URBAN MEDIUM VOLTAGE DISTRIBUTION NETWORK WITH CROSS CONNECTION URBAN MEDIUM VOLTAGE DISTRIBUTION NETWORK WITH CROSS CONNECTION Vladimir BLAZEK, Petr SKALA Brno University of Technology - Czech Republic blazek@feec.vutbr.cz The article sets out to evaluate the effectiveness

More information

Introduction to Substation Design TADP 542

Introduction to Substation Design TADP 542 Introduction to Substation Design TADP 542 Distribution Substations- Drawings and Documentation Instructor: Richard Snell Transmission & Distribution Program Drawings Drawings are prime method for communicating

More information

Miniature substations: What they are really capable of delivering

Miniature substations: What they are really capable of delivering Miniature substations: What they are really capable of delivering by Rhett Kelly and Greg Whyte, ACTOM Medium Voltage Switchgear The latest edition of the South African national standard for miniature

More information

T-P22 Low Voltage Cable Fault Locator

T-P22 Low Voltage Cable Fault Locator T-P22 Low Voltage Cable Fault Locator Remotely controllable TDR & Disturbance Recorder designed specifically for low voltage power cable fault location Locates permanent, intermittent & transitory faults

More information

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA

PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA PROCEDURE FOR INSPECTION OF ELECTRICAL INSTALLATIONS ABOVE 250KVA Generally inspection of electrical installations is carried out under Regulation-30 (Periodical inspection & testing) & Regulation-43 (Approval

More information

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications Electrical Power Systems PSL2 Investigates the principles and operating characteristics of single-phase and three-phase power and distribution transformers Key Features Educational transformers with fully

More information

Single Line Diagram of Substations

Single Line Diagram of Substations Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission lines are

More information

List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom.

List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom. List of Item Codes of Various Materials Purchased by Materials Management Cell(H.O.,Mumbai) through e-tender website https://cpa1.mahadiscom.in : M.M. PURCHASE GROUP-I : New Service Connection (N.S.C.)

More information

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E Electrical Switchgear & Power Transformer Testing H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E www.ictd.ae ictd@ictd.ae Course Introduction: This will provide you with practical knowledge

More information

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Numbering System for Protective Devices, Control and Indication Devices for Power Systems Appendix C Numbering System for Protective Devices, Control and Indication Devices for Power Systems C.1 APPLICATION OF PROTECTIVE RELAYS, CONTROL AND ALARM DEVICES FOR POWER SYSTEM CIRCUITS The requirements

More information

ABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications Ron Pate, Product Manager, Instrument Transformers and Sensors

ABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications Ron Pate, Product Manager, Instrument Transformers and Sensors ABB CUSTOMER WORLD, MARCH 13-16, 2017 Sensors in Critical Applications 050511 Ron Pate, Product Manager, Instrument Transformers and Sensors Sensors in Critical Applications Presentation code 050511 Speakers

More information

INCREASING NETWORK CAPACITY BY OPTIMISING VOLTAGE REGULATION ON MEDIUM AND LOW VOLTAGE FEEDERS

INCREASING NETWORK CAPACITY BY OPTIMISING VOLTAGE REGULATION ON MEDIUM AND LOW VOLTAGE FEEDERS INCREASING NETWORK CAPACITY BY OPTIMISING VOLTAGE REGULATION ON MEDIUM AND LOW VOLTAGE FEEDERS Carter-Brown Clinton Eskom Distribution - South Africa cartercg@eskom.co.za Gaunt CT University of Cape Town

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Subsea Power Grid Control System

Subsea Power Grid Control System Subsea Power Grid Control System Development Manager Offshore,Oil & Gas Integrated System Solutions 08.02.2012 Siemens Oil & Gas solutions - Offshore 2011. All rights reserved. Contents Motivation for

More information

Application for electricity connections Housing development for up to four dwellings

Application for electricity connections Housing development for up to four dwellings Electricity Thank you for considering Western Power Distribution for your electricity connections. We have put together these notes to help you fill out your and to ensure we receive all the correct information

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING. Rev. 01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-I) UNDERGROUND NETWORK GROUNDING Rev. 01 This specification is property of SEC and subject to change or modification without any notice

More information

Solutions. Remotek's Advantages

Solutions. Remotek's Advantages About Remotek Remotek Corporation specialized in Research, Design and Production of radio coverage solutions for all types of mobile radio network, RF components and the provision of relevant services.

More information

Unit 2. Single Line Diagram of Substations

Unit 2. Single Line Diagram of Substations Unit 2 Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission

More information

Hamdy Faramawy Senior Application Specialist ABB Sweden

Hamdy Faramawy Senior Application Specialist ABB Sweden Design, Engineering and Application of New Firm Capacity Control System (FCCS) Mohammed Y. Tageldin, MSc. MIET Senior Protection Systems Engineer ABB United Kingdom mohammed.tageldin@gb.abb.com Hamdy Faramawy

More information

Instrument Transformer Services (ITS) Voltage / Potential Transformer Reclassification

Instrument Transformer Services (ITS) Voltage / Potential Transformer Reclassification Instrument Transformer Services (ITS) Voltage / Potential Transformer Reclassification Schneider Electric Instrument Transformer Services VT/PT Reclassification 1 CONTENTS PURPOSE OF THIS DOCUMENT 3 EXECUTIVE

More information

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION

Technical description MT24. User manual WARNING GENERAL INSTRUCTIONS GENERAL DESCRIPTION WARIG The equipment makes a compact set of the switchboard. Just this set is safe from the point of electrical shock. Therefore do not use other power supplies or circuits than mentioned in this direction

More information

Three-Phase Transformer Test Systems

Three-Phase Transformer Test Systems Three-Phase Transformer Test Systems PHENIX TECHNOLOGIES R Testing Applications Models Available Perform tests on utility distribution and power transformers in accordance with IEC 60076 and ANSI / IEEE

More information

Constant Current Regulator INDUPERM type CCR 961

Constant Current Regulator INDUPERM type CCR 961 Constant Current Regulator INDUPERM type CCR 961 Standard Technical Description 961.001-GB List of content General description 2 CCR cubicle.. 4 CCR module. 5 Transformer cubicle... 10 Output Transformer..

More information

INTEGRATED TRANSMISSION PLAN Glossary

INTEGRATED TRANSMISSION PLAN Glossary INTEGRATED TRANSMISSION PLAN Glossary SEPTEMBER 2017 GLOSSARY Term AC ACM asset health and asset health index (AHI) automatic underfrequency load shedding (AUFLS) availability bus cable capacitor bank

More information

TRANSMISSION ASSETS. Filed: September 12, 2006 EB Exhibit D1 Tab 1 Schedule 2 Page 1 of INTRODUCTION

TRANSMISSION ASSETS. Filed: September 12, 2006 EB Exhibit D1 Tab 1 Schedule 2 Page 1 of INTRODUCTION Filed: September, 00 EB-00-00 Schedule Page of TRANSMISSION ASSETS.0 INTRODUCTION 0 Hydro One Networks Inc. is licensed by the Ontario Energy Board (OEB) to own, operate and maintain transmission facilities

More information

PME specialises in developing, implementing and maintaining solutions to the Mining industry.

PME specialises in developing, implementing and maintaining solutions to the Mining industry. +675 325 3533 PME specialises in developing, implementing and maintaining solutions to the industry. Our Services: Engineering & design EPC services High voltage design, installations and testing Installation

More information

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD. Our Ref : 2/2018- Date : Messrs: Dear Sir, Tender 2/2018 Main Transformers You are kindly requested to quote for the supply and delivery DDP to our stores the transformers detailed in the attached schedules

More information

FAQ ON EARTHING STANDARDS 16/08/2018

FAQ ON EARTHING STANDARDS 16/08/2018 FAQ ON EARTHING STANDARDS 16/08/2018 This document has been updated to include changes made to substation earthing layouts that have been made necessary due to copper theft. The main changes to be aware

More information

Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan

Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan Arizona Public Service Company and the Transmission Partnership for National Electric Power Company of Jordan Mark Hackney October 5-8, 2009 Amman, Jordan Energy Control Center Layout 2 Energy Control

More information

ELECTRICAL POWER TRANSMISSION TRAINER

ELECTRICAL POWER TRANSMISSION TRAINER ELECTRICAL POWER TRANSMISSION TRAINER ELECTRICAL POWER TRANSMISSION TRAINER This training system has been designed to provide the students with a fully comprehensive knowledge in Electrical Power Engineering

More information

Substation Preventive Maintenance

Substation Preventive Maintenance Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS

More information

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear

More information

700 Series AC Dielectric Test Sets

700 Series AC Dielectric Test Sets 700 Series AC Dielectric Test Sets AC Test Systems HAEFELY HIPOTRONICS standard line of AC Test Systems is designed to perform high voltage AC tests on electrical apparatus in accordance with IEC60, IEEE

More information

VOLTAGE MANAGEMENT BY THE APPORTIONMENT OF TOTAL VOLTAGE DROP IN THE PLANNING AND OPERATION OF COMBINED MEDIUM AND LOW VOLTAGE DISTRIBUTION SYSTEMS

VOLTAGE MANAGEMENT BY THE APPORTIONMENT OF TOTAL VOLTAGE DROP IN THE PLANNING AND OPERATION OF COMBINED MEDIUM AND LOW VOLTAGE DISTRIBUTION SYSTEMS 66 SOUTH AFRICAN INSTITUTE OF ELECTRICAL ENGINEERS Vol.97(1) March 2006 VOLTAGE MANAGEMENT BY THE APPORTIONMENT OF TOTAL VOLTAGE DROP IN THE PLANNING AND OPERATION OF COMBINED MEDIUM AND LOW VOLTAGE DISTRIBUTION

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date

More information

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets Abstract: For decades it has been recognized that partial discharge assessment is an excellent method

More information

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products

More information

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences

More information

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS S1. Standard Interconnection Methods with Typical Circuit Configuration for Single or Multiple Units Note: The protection requirements

More information

Connection of Embedded Generating Plant up to 5MW

Connection of Embedded Generating Plant up to 5MW Engineering Recommendation No.3 of the Electricity Distribution Code Connection of Embedded Generating Plant up to 5MW Version 1.0 30th November 2005 Prepared by: Al Ain Distribution Company, Abu Dhabi

More information

LV Compensation & Filtering Products

LV Compensation & Filtering Products GE Grid Solutions LV Compensation & Filtering Products Providing Power Quality and Energy Efficiency Low (LV) reactive power compensation and harmonic filtering solutions help customers to improve the

More information

Power Quality. Case Study. Conrad Bottu Laborelec January 2008

Power Quality. Case Study. Conrad Bottu Laborelec January 2008 Case Study Electromagnetic compatibility (EMC) study Breakdown of low voltage electronic equipment in a 25 kv substation Conrad Bottu Laborelec January 2008 Power Quality Power Quality 1 Introduction Description

More information

One line and Three line diagrams Schematics Wiring Diagrams Logic ladders Ancillary prints Pictorial instructions

One line and Three line diagrams Schematics Wiring Diagrams Logic ladders Ancillary prints Pictorial instructions One line and Three line diagrams Schematics Wiring Diagrams Logic ladders Ancillary prints Pictorial instructions One line diagram (1) One line diagrams will typically show in a simple fashion an over

More information

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000 STS 4000 Multifunction substation maintenance & commissioning test system for current, voltage and power transformers. Capacitance / Tan Delta diagnostic system with the optional module TD 5000. w w w.

More information

BIRD ISLAND FLATS SUBSTATION (BUILDING 67) ONE LINE DIAGRAM SET# 23 LEGEND DRAW-OUT CIRCUIT BREAKER DRAW-OUT CIRCUIT BREAKER, DRAW-OUT FUSES DRAW-OUT FUSES AND POTENTIAL TRANSFORMERS CABLE CONNECTION POTENTIAL

More information

NESSY NETWORK VOLTAGE STABILISATION SYSTEM. Permanent protection against voltage fluctuations in the low-voltage network

NESSY NETWORK VOLTAGE STABILISATION SYSTEM. Permanent protection against voltage fluctuations in the low-voltage network NESSY NETWORK VOLTAGE STABILISATION SYSTEM Permanent protection against voltage fluctuations in the low-voltage network OLIVER ONLINE VOLTAGE REGULATION NESSY NESSY NESSY NESSY 2 TABLE OF CONTENTS VOLTAGE

More information

QUESTIONNAIRE for Wind Farm Power Stations only

QUESTIONNAIRE for Wind Farm Power Stations only TRANSMISSION SYSTEM OPERATOR QUESTIONNAIRE for Wind Farm Power Stations only To be submitted by the Generation Licensees together with the Application for Connection Certificate according to IEC 61400-21

More information

Modular range of digital protection relays

Modular range of digital protection relays S e p a m s e r i e s 2 0, 4 0, 8 0 Modular range of digital protection relays Fast Dependable Simple Fast response Maximum dependability Your electrical equipment is under control. With Sepam protection

More information

Accr. 002-Test EN-ISO (2005)

Accr. 002-Test EN-ISO (2005) Electromagnetic compatibility LAB > Examination of compliance with EMC standards > Measurement of radio-disturbances > Immunity tests > 2004/108/EC EMC Directive > CE Marking > Measurement of electromagnetic

More information

Control and Monitoring of Subsea Power Grid

Control and Monitoring of Subsea Power Grid Control and Monitoring of Subsea Power Grid 26.05.2011 Siemens Oil & Gas solutions - Offshore 2010. All rights reserved. Siemens Subsea Solution Segments 5 Main Solution Segments That are Evolving Subsea

More information

Autotransformer Condition Monitoring Systems

Autotransformer Condition Monitoring Systems Autotransformer Condition Monitoring Systems The Bidders shall offer separately the following systems of par.1 Integrated Condition Monitoring System and par.2 UHF PD Monitoring System. Two systems following

More information

POWER QUALITY INITIATIVES IN SINGAPORE. S T Chang, K Y Chua, C C Siew and T L Tan. PowerGrid Ltd, Singapore SUMMARY

POWER QUALITY INITIATIVES IN SINGAPORE. S T Chang, K Y Chua, C C Siew and T L Tan. PowerGrid Ltd, Singapore SUMMARY POWER QUALITY INITIATIVES IN SINGAPORE S T Chang, K Y Chua, C C Siew and T L Tan PowerGrid Ltd, Singapore SUMMARY PowerGrid Ltd, a subsidiary of Singapore Power Ltd, is responsible for the transmission

More information

Protection relays and transformers

Protection relays and transformers NEW ZEALAND WWW.LPINZ.CO.NZ Unit 6/22 Moselle Ave, Henderson, Auckland, New Zealand PO Box 21-872, Henderson, Auckland, New Zealand Phone:+64 9 833 5749 Email:info@LPINZ.co.nz Web: www.lpinz.co.nz Protection

More information

WIRELESS THREE PHASE LINE FAULT MONITORING

WIRELESS THREE PHASE LINE FAULT MONITORING WIRELESS THREE PHASE LINE FAULT MONITORING Vaishnavi Kailas Pardeshi 1, Pooja Anil Kawade 2, Rutuja Ratanakar Kshirsagar 3 1,2,3 Department Electrical Engineer, Sandip Polytechnic, Nashik Maharashtra (India)

More information

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Efacec work every day to anticipate solutions for a sustainable world in the new energy era. Transformers Efacec is the largest industrial portuguese company of the electric and electromechanical sector developing high technology products, solutions and systems used every day by millions of people

More information

Medium-voltage in-phase regulator system Energy Management

Medium-voltage in-phase regulator system Energy Management Medium-voltage in-phase regulator system Energy Management Challenges Distributed power generation can have an enormous impact on grid performance. The challenge of equalizing voltage fluctuations is especially

More information

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01

SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING. Rev. 01 SEC DISTRIBUTION GROUNDING STANDARD SDCS-03 Part-II Rev.01 SDCS-03 DISTRIBUTION NETWORK GROUNDING CONSTRUCTION STANDARD (PART-II) OVERHEAD NETWORK GROUNDING Rev. 01 This specification is property of SEC

More information

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality. PART 1: GENERAL 1.01 Wiring Devices A. This section of the standard includes design requirements for wiring connections, including receptacles and switches to equipment specified in other sections. 1.02

More information

POWERING SUBSEA LOADS OVER LONG DISTANCES

POWERING SUBSEA LOADS OVER LONG DISTANCES Space optimiced multidirve Solutions PETRONAS - PETRAD - INTSOK CCOP DEEPWATER SUBSEA TIE-BACK POWERING SUBSEA LOADS OVER LONG DISTANCES January 26, 2011 Slide 1 Presentation Overview History Typical Subsea

More information

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks We reserve all rights to this document, and the subject-matter it deals with. Duplication, dissemination

More information

G. KOEPPL Koeppl Power Experts Switzerland

G. KOEPPL Koeppl Power Experts Switzerland PS3: Substation Design: New Solutions and Experiences Bus-Node Substation A Big Improvement in Short-Circuit and Switching Properties at Reduced Substation Costs G. KOEPPL Koeppl Power Experts Switzerland

More information

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description: VTOP 2(1) X Dry Insulated voltage transformer (VT) There are two designs of this voltage transformers: - VTOP 1-X single phase, dry insulated

More information

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS Management has tentatively approved your request subject to the following conditions: 1. All distribution materials/equipment must be purchased

More information

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION SECTION 16715 COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION PART 1 - GENERAL 1.01 SECTION DESCRIPTION AND BASIC REQUIREMENTS A. The Electrical Power Distribution System provides power distribution from

More information

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems

CITY SERIES. Compact, fully equipped cable fault location, test and diagnostic systems CITY SERIES Compact, fully equipped cable fault location, test and diagnostic systems Tailored to fit to small vehicles Easy operation in restricted spaces Centrally controlled, fully automatic system

More information