POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Size: px
Start display at page:

Download "POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS."

Transcription

1 POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

2 This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products described here. Moving together

3 CONTENTS 1. Metal Enclosed Capacitor Banks and Harmonic Filters 4 2. Rack Mount Capacitor Banks and Harmonic Filters Pole Mount Capacitor Banks Studies, Simulations and Technical Support 18 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

4 1. METAL ENCLOSED CAPACITOR BANKS AND HARMONIC FILTERS 4 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

5 1. METAL ENCLOSED CAPACITOR BANKS AND HARMONIC FILTERS CUSTOMIZED SOLUTIONS FOR A WIDE RANGE OF USERS Custom engineered solutions for both utility and industrial applications, ARTECHE capacitor systems and harmonic filters are available in both pad mount or switchgear style enclosures. Switchgear style units are typically located at the main service entrance of an industrial facility and can be supplied as automatic switching units to maintain desired power factor and harmonics under changing load conditions. ARTECHE offers in addition, and depending on the application, units with tuned or detuned reactors to build up different solutions in order to avoid resonance of the capacitors with the system inductance, or to absorb one or several particular harmonics. Pad mounted systems accommodate underground distribution installations. Metal Enclosed Systems. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 5

6 1. METAL ENCLOSED CAPACITOR BANKS AND HARMONIC FILTERS APPLICABLE STANDARDS ARTECHE standard designs meet among others, with the two main international standards: IEC 60871, IEC IEEE STD 18 and CSA ratings. Metal Enclosed Systems. 6 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

7 1. METAL ENCLOSED CAPACITOR BANKS AND HARMONIC FILTERS GENERAL DESCRIPTION POWER CAPACITOR: ARTECHE supplies single phase or three phase capacitors with stainless steel cases. Capacitors are free of PCB s and available in powers from 50 up to kvar (individual units). These capacitors can be either externally fused or internally fused. Each unit has a discharge resistor to reduce the voltage between the terminals to 50 V in five minutes or 75 V in ten minutes according to IEEE and IEC standards respectively. TUNING REACTORS: Tuning reactors are added in harmonic filters. These reactors are generally iron core type and are an integral part of the capacitor bank. As an option, ARTECHE is able to supply air core reactors which are enclosed separately upon request. INRUSH REACTORS: Inrush reactors are necessary in the capacitor banks for the purpose of limiting inrush currents and back-to-back switching events. CURRENT LIMITING FUSES: These are provided for the protection of short circuit currents, and internal faults in the capacitors. INSTRUMENT TRANSFORMERS: Automatic capacitor banks require voltage and current signals which may be provided by the customer or obtained from the bus through instrument transformers already in place. Current transformers or voltage transformers can be supplied for neutral unbalance protection depending on the bank connection type. SWITCHING ELEMENTS: Switching elements are specially designed for handling capacitive loads. ARTECHE offers the best technical solution on project basis, and supplies capacitor switches, contactors, or circuit breakers depending on the specific application. SURGE ARRESTERS: Surge Arresters protect the capacitor banks from voltage surges and lightning. ZERO VOLTAGE CONTROL: Available with capacitor switches, this type of technology is not a standard design and must be requested specifically. Capacitor switching phenomena are minimized. GROUNDING SWITCH: The grounding switch ensures that capacitors are fully discharged for maintenance. CONTROL AND PROTECTION SYSTEM: The main protections are neutral unbalance and overcurrent protection. Other schemes are available. Power Factor Correction Capacitors. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 7

8 1. METAL ENCLOSED CAPACITOR BANKS AND HARMONIC FILTERS TECHNICAL CHARACTERISTICS CONTENTS Capacity Voltage Frequency ANY kvar rating Up to 38 kv 50 Hz or 60 Hz Fixed Type Automatic Automatic Multistep Service Enclosure Temperature range Tuned frequency Indoor or Outdoor IP or NEMA -30 to 50 C (Other temperatures available upon request) According to harmonic distortion. Any tuned frequency. Metal Enclosed Systems. 8 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

9 ARTECHE POWER QUALITY Customized solutions. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 9

10 2. RACK MOUNT CAPACITOR BANKS AND HARMONIC FILTERS 10 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

11 2. RACK MOUNT CAPACITOR BANKS AND HARMONIC FILTERS SUBSTATION SUITABILITY Capacitor systems for reactive compensation and harmonic filter systems are available in rack mount configurations for use in either covered or open construction substation applications. Rack mounts are manufactured with hot zinc immersion galvanized steel or aluminium. Capacitor banks and harmonic filters are shunt connected to the system to provide reactive power. In the case of harmonic filters, the banks are tuned or detuned to reduce or eliminate harmonics that may be present in the system. Banks can be manufactured in various VAr and Voltage requirements. The banks can be either fixed or switched with protection options. ARTECHE OFFER ARTECHE capacitor banks and harmonic filters can be manufactured in a variety of voltage or reactive power requirements. ARTECHE can offer different protection schemes. For example: Floating Wye. Double Wye. Fuseless. H configuration. Voltage differential. Grounded Wye. Delta. Internally Fused.... or any configuration. ARTECHE PQ offers over 20 years experience in the design and manufacture of reactive power compensation and harmonic filtering systems for medium and high voltage networks. APPLICABLE STANDARDS ARTECHE standard designs meet among others, with the two main international standards: IEC 60871, IEC IEEE STD 18 and CSA ratings. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 11

12 2. RACK MOUNT CAPACITOR BANKS AND HARMONIC FILTERS GENERAL DESCRIPTION CAPACITORS: ARTECHE supplies single phase or three phase capacitors with stainless steel cases. Capacitors are free of PCB s and available in powers from 50 up to kvar (individual units). These capacitors can be either externally fused, internally fused, or fuseless. Each unit has a discharge resistor to reduce the voltage between the terminals to 50 V in five minutes or 75 V in ten minutes according to IEEE and IEC standards respectively. CAPACITOR FUSING: In case of externally fused capacitors, fuses used are expulsion type. TUNING REACTORS: For Harmonic filters tuning reactors are added. ARTECHE supplies reactors with iron core or air core as per customer request. INRUSH REACTORS: Are necessary in the capacitor banks for the purpose of limiting inrush currents and backto-back switching events.. SWITCHING ELEMENTS: Switching elements are specially designed for handling capacitive loads. ARTECHE offers the best technical solution on project basis, and supplies capacitor switches, contactors, or circuit breakers depending on the specific application. CONTROL AND PROTECTION RELAYS: Multifunction relay, overcurrent, voltage, neutral, and automatic control functions are available. SURGE ARRESTERS: Surge Arresters protect the capacitor banks from voltage surges and lightning. CUT OUTS: Power main fuses can be used as disconnecting switches with manual operation. ZERO VOLTAGE CONTROL: Available with capacitor switches, this type of equipment is not a standard design and must be requested specifically. Capacitor switching phenomena are minimized. INSULATORS: Porcelain station post insulators meet IEC or ANSI standards. STRUCTURE: Galvanized steel or aluminium INSTRUMENT TRANSFORMERS: Automatic capacitor banks require voltage and current signals which may be provided by the customer or obtained from the bus through instrument transformers already in place. Current transformers or voltage transformers can be supplied for neutral unbalance protection depending on the bank connection type. GROUNDING SWITCH: The grounding switch ensures that capacitors are fully discharged for maintenance. CONTROL CABINET: Used for capacitor banks or harmonic filters with automatic control. Can be either outdoor or indoor assembled. The main protections are neutral unbalance and overcurrent protection. Other schemes are available. 12 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

13 2. RACK MOUNT CAPACITOR BANKS AND HARMONIC FILTERS TECHNICAL CHARACTERISTICS CONTENTS Capacity Voltage Frequency Type ANY kvar rating Up to 245 kv 50 Hz or 60 Hz Fixed or Automatic Internally fused Capacitor type Externally fused Fuseless Service Structure Temperature range Tuned frequency Outdoor Galvanized Iron structure or aluminium -30 to 50 C (Other temperatures available upon request) According to harmonic distortion. Any tuned frequency. Rack Mount Capacitor Banks. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 13

14 3. POLE MOUNT CAPACITOR BANKS 14 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

15 3. POLE MOUNT CAPACITOR BANKS GENERAL DESCRIPTION The most effective way of reactive power compensation is achieved when the capacitor banks are distributed over the entire electrical system, the same way inductive loads are distributed. The reactive compensation reduces the load on the electrical infrastructure installed upstream. Reactive power compensating as close as possible to the load leads to a better overall performance. ARTECHE offers a full range of pole mounted solutions to improve power factor, reduce heat, or improve the system voltage profile. Distribution systems typically carry energy in high voltage levels in order to avoid system losses. However, the lower the voltage and the greater the length, more suitable is the use of intermediate capacitor banks in the distribution system to restore or maintain the voltage level and to compensate reactive power. ARTECHE pole mounted capacitor banks meet in a simple, reliable and accessible way, the reactive power compensation and voltage level support needs in distribution lines. Light, compact and easy to install, the structure that supports the equipment represents an important advantage when few space is available. ARTECHE pole mounted capacitor banks have minimal maintenance requirements. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 15

16 3. POLE MOUNT CAPACITOR BANKS TECHNICAL CHARACTERISTICS CONTENTS Frequency Type Capacities Voltage 50/60 Hz Automatic / Fixed from 150 kvar to kvar as standard Up to 38 kv Wye Connection Floating Wye Delta Control Communication Local Remote Radio Pole Mount Capacitor Banks. 16 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

17 ARTECHE POWER QUALITY Trust and reliability. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 17

18 4. STUDIES, SIMULATIONS AND TECHNICAL SUPPORT 18 Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions

19 4. STUDIES, SIMULATIONS AND TECHNICAL SUPPORT GENERAL DESCRIPTION ARTECHE offers all necessary support to customers to provide the best solution and equipment depending on the requirements of the system. Our engineering team performs electrical studies simulating both the steady state and transient conditions, so that the best solution in terms of reactive power compensation and harmonics cancellation can be designed for each individual project. ARTECHE has the most reliable software and modelling tools, such as PSS/E, DigSilent, EMTP-AT, as well as our own developed and validated programs. Among others, the following studies can be performed: Protective-device coordination studies. Short circuit analysis. Reliability studies. Switching transient studies. Load flow studies. Power quality analysis. Harmonic analysis. Voltage support studies. Dynamic stability studies. Voltage stability studies. System impact studies. ARTECHE has worldwide experience in analysing the integration of renewable energies into electrical networks, particularly in the wind power sector: GRID CODE VALIDATION Simulation of complete wind farm (WTGs, transformers and electrical lines) to perform: Power flow analyses to determine electrical losses and voltage variations at the Point of Common Coupling (PCC) for different WTG power generation set points and power factors. P-Q curve generation. Analysis of external equipment needed (voltage control ancillary services). TOTAL HARMONIC DISTORTION THD calculation of the wind farm at the PCC (current harmonics and voltage harmonics). Analysis of external equipment needed (active or passive filters). REACTIVE POWER GENERATION Analysis of equipment needed to accomplish the power factor and voltage requirements of the installation at the PCC. Power Factor Correction. Harmonic Filtering. Medium and High Voltage Solutions 19

20 Moving together ARTECHE_CT_PQ_MVHV_EN Version: A1 ARTECHE

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter PFCC-1000 series Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter Powerful Flexibility Durability - Quality email.us.at:.quotes@tanddproducts.com www.tanddproducts.com

More information

Welcome. Power Survey International

Welcome. Power Survey International Welcome Company profile Established since 1948 Manufacturer of low and medium voltage products: Power Factor correction system Harmonic Filter system Steel Cabinet customized to your needs Other products

More information

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS High voltage shunt capacitor banks Alstom Grid high voltage shunt capacitor bank offering is divided in: By bank construction HV open rack capacitor banks HV enclosed capacitor banks By bank design HV

More information

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262) APQline Active Harmonic Filters N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI 53051 P. (262) 754-3883 F. (262) 754-3993 www.apqpower.com Power electronic equipment and AC-DC power conversion equipment contribute

More information

SHUNT CAPACITOR BANK DESIGN AND PROTECTION BASICS

SHUNT CAPACITOR BANK DESIGN AND PROTECTION BASICS SHUNT CAPACITOR BANK DESIGN AND PROTECTION BASICS Introduction Shunt capacitor units are typically used to deliver capacitive reactive compensation or power factor correction. The use of shunt capacitor

More information

Wind Power Facility Technical Requirements CHANGE HISTORY

Wind Power Facility Technical Requirements CHANGE HISTORY CHANGE HISTORY DATE VERSION DETAIL CHANGED BY November 15, 2004 Page 2 of 24 TABLE OF CONTENTS LIST OF TABLES...5 LIST OF FIGURES...5 1.0 INTRODUCTION...6 1.1 Purpose of the Wind Power Facility Technical

More information

LV Compensation & Filtering Products

LV Compensation & Filtering Products GE Grid Solutions LV Compensation & Filtering Products Providing Power Quality and Energy Efficiency Low (LV) reactive power compensation and harmonic filtering solutions help customers to improve the

More information

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre. General PQ: Power Quality has multiple issues involved. Thus, need to have some benchmarking standards. Very little is spoken about the LT supply installation within an industry. There is need to understand

More information

Principles for Controlling Harmonics

Principles for Controlling Harmonics Principles for Controlling Harmonics Harmonic distortion is present to some degree on all power systems. Fundamentally, one needs to control harmonics only when they become a problem. There are three common

More information

Thyristorised Automatic Power Factor

Thyristorised Automatic Power Factor Thyristorised Automatic Power Factor Correction with 7% D Tune Harmonics Suppression (Reactor/Filtering) System Power quality? In the present Low voltage (LV) industrial distribution system the power factor

More information

Harmonic control devices

Harmonic control devices ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 24 1 Today Harmonic control devices In-line reactors (chokes)

More information

SIMPLE SOLUTIONS FOR IMPROVING LIFE OF BREAKERS USED IN TRANSMISSION AND DISTRIBUTION SYSTEMS

SIMPLE SOLUTIONS FOR IMPROVING LIFE OF BREAKERS USED IN TRANSMISSION AND DISTRIBUTION SYSTEMS SIMPLE SOLUTIONS FOR IMPROVING LIFE OF BREAKERS USED IN TRANSMISSION AND DISTRIBUTION SYSTEMS Dr. V. R. Kanetkar and Mr. K. E. Shinde Shreem Electric Limited, Jaysingpur Dist. Kolhapur, Maharashtra State

More information

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017

Grid codes and wind farm interconnections CNY Engineering Expo. Syracuse, NY November 13, 2017 Grid codes and wind farm interconnections CNY Engineering Expo Syracuse, NY November 13, 2017 Purposes of grid codes Grid codes are designed to ensure stable operating conditions and to coordinate the

More information

CONTENTS. 1. Introduction Generating Stations 9 40

CONTENTS. 1. Introduction Generating Stations 9 40 CONTENTS 1. Introduction 1 8 Importance of Electrical Energy Generation of Electrical Energy Sources of Energy Comparison of Energy Sources Units of Energy Relationship among Energy Units Efficiency Calorific

More information

Tab 2 Voltage Stresses Switching Transients

Tab 2 Voltage Stresses Switching Transients Tab 2 Voltage Stresses Switching Transients Distribution System Engineering Course Unit 10 2017 Industry, Inc. All rights reserved. Transient Overvoltages Decay with time, usually within one or two cycles

More information

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved. Pomona, CA, May 24 & 25, 2016 Tertiary Winding Design in wye-wye Connected Transformers Scope of Presentation > Tertiary vs. Stabilizing Winding? Tertiary vs. Stabilizing Winding? Need for Stabilizing

More information

Do Capacitor Switching Transients Still Cause Problems?

Do Capacitor Switching Transients Still Cause Problems? Do Capacitor Switching Transients Still Cause Problems? Mark McGranaghan We have been evaluating problems related to capacitor switching transients for many years. Capacitor banks have been used on distribution

More information

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Generation Interconnection Requirements at Voltages 34.5 kv and Below Generation Interconnection Requirements at Voltages 34.5 kv and Below 2005 March GENERATION INTERCONNECTION REQUIREMENTS AT 34.5 KV AND BELOW PAGE 1 OF 36 TABLE OF CONTENTS 1. INTRODUCTION 5 1.1. Intent

More information

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM Abstract Efficient operation of the electrical system of any facility is essential to controlling operational costs while maximizing

More information

Harmonic control devices. ECE 528 Understanding Power Quality

Harmonic control devices. ECE 528 Understanding Power Quality ECE 528 Understanding Power Quality http://www.ece.uidaho.edu/ee/power/ece528/ Paul Ortmann portmann@uidaho.edu 208-733-7972 (voice) Lecture 12 1 Today Harmonic control devices In-line reactors (chokes)

More information

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900

Coil Products Beginnings 1960 State of the Art. Customer partnership around the globe. Continuous innovation since 1900 Coil Products Coil Products Customer partnership around the globe More than 250,000 coil products delivered to more than 170 countries. More than 60 years of operational experience. 35,000 in Europe 13,000

More information

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements Division 502 Technical Applicability 1(1) Section 502.1 applies to: Expedited Filing Draft August 22, 2017 the legal owner of an aggregated generating facility directly connected to the transmission system

More information

Harmonic filter design for electrified railways

Harmonic filter design for electrified railways filter design for electrified railways DIgSILENT USER GROUP Sydney 5 September 2013 M Jansen, S Hagaman, T George Railway electrification project Adds significant unbalanced non-linear load to the grid

More information

Utility Interconnection and System Protection

Utility Interconnection and System Protection Utility Interconnection and System Protection Alex Steselboim President, Advanced Power Technologies, Inc. Utility paralleling vs. isolated operation. Isochronous kw load sharing Reactive power (VAR) sharing

More information

Single Line Diagram of Substations

Single Line Diagram of Substations Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission lines are

More information

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements Applicability 1(1) Section 502.1 applies to the ISO, and subject to the provisions of subsections 1(2), (3) and (4) to any: (a) a new wind aggregated generating facility to be connected to the transmission

More information

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY

THE COMPREHENSIVE APPROACH TO FACILITY POWER QUALITY by Cesar Chavez, Engineering Manager, Arteche / Inelap, and John Houdek, President, Allied Industrial Marketing, Inc. Abstract: Industrial facility harmonic distortion problems can surface in many different

More information

FERRORESONANCE SIMULATION STUDIES USING EMTP

FERRORESONANCE SIMULATION STUDIES USING EMTP FERRORESONANCE SIMULATION STUDIES USING EMTP Jaya Bharati, R. S. Gorayan Department of Electrical Engineering Institute of Technology, BHU Varanasi, India jbharatiele@gmail.com, rsgorayan.eee@itbhu.ac.in

More information

Index. b back-flashover 245 biomass 207 breakers 74 buchholz protection 235 busbar sectionalizer 193 business enterprises 18

Index. b back-flashover 245 biomass 207 breakers 74 buchholz protection 235 busbar sectionalizer 193 business enterprises 18 331 Index a activity plan 318 agricultural enterprise 21 annual increase factor 12 annuity factor 44, 156 annuity method 38 ANSI code numbers 237 arrester, protection level 245 assessment of losses 38

More information

This document covers common questions concerning the design of an effectively grounded system.

This document covers common questions concerning the design of an effectively grounded system. This document covers common questions concerning the design of an effectively grounded system. To prevent against temporary overvoltage conditions when a line-to-ground fault occurs on the power grid.

More information

UNIT-4 POWER QUALITY MONITORING

UNIT-4 POWER QUALITY MONITORING UNIT-4 POWER QUALITY MONITORING Terms and Definitions Spectrum analyzer Swept heterodyne technique FFT (or) digital technique tracking generator harmonic analyzer An instrument used for the analysis and

More information

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form) IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form) Transmission Provider: IDAHO POWER COMPANY Designated Contact Person: Jeremiah Creason Address: 1221 W. Idaho Street, Boise ID 83702 Telephone

More information

Unit 2. Single Line Diagram of Substations

Unit 2. Single Line Diagram of Substations Unit 2 Single Line Diagram of Substations Substations Electric power is produced at the power generating stations, which are generally located far away from the load centers. High voltage transmission

More information

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB

This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB This webinar brought to you by The Relion Product Family Next Generation Protection and Control IEDs from ABB Relion. Thinking beyond the box. Designed to seamlessly consolidate functions, Relion relays

More information

Power Factor & Harmonics

Power Factor & Harmonics Power Factor & Harmonics Andy Angrick 2014 Harmonic Distortion Harmonic problems are becoming more apparent because more equipment that produce harmonics are being applied to power systems Grounding Harmonics

More information

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar.

Technical Report. Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by. Dr. V. R. Kanetkar. Technical Report on Zero Reactive Power Passive Current Harmonic Filter (ZRPPCHF) (In House Case Study) Prepared by Dr. V. R. Kanetkar (February 2015) Shreem Electric Limited (Plot No. 43-46, L. K. Akiwate

More information

Design and Simulation of Passive Filter

Design and Simulation of Passive Filter Chapter 3 Design and Simulation of Passive Filter 3.1 Introduction Passive LC filters are conventionally used to suppress the harmonic distortion in power system. In general they consist of various shunt

More information

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS AND MEDIUM-SIZE FACILITIES (5,000-25,000KW) CONNECTED

More information

CAPACITOR SWITCHING TRANSIENT ANALYSIS ON A TRANSMISSION GRID SUBSTATION (CASE STUDY: THULHIRIYA GSS)

CAPACITOR SWITCHING TRANSIENT ANALYSIS ON A TRANSMISSION GRID SUBSTATION (CASE STUDY: THULHIRIYA GSS) CAPACITOR SWITCHING TRANSIENT ANALYSIS ON A TRANSMISSION GRID SUBSTATION (CASE STUDY: THULHIRIYA GSS) Don Lishan Prasanga Munasinghe (119131 H) Dissertation submitted in partial fulfillment of the requirement

More information

Tab 8 Surge Arresters

Tab 8 Surge Arresters s en em Tab 8 Surge Arresters Si Distribution System Engineering Course Unit 10 2017 Industry Inc., All Rights Reserved Surge Arresters The main protective devices against system transient overvoltages.

More information

Substation Design Volume VII

Substation Design Volume VII PDHonline Course E474 (5 PDH) Substation Design Volume VII Other Major Equipment Instructor: Lee Layton, P.E 2015 PDH Online PDH Center 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088

More information

Optimizing HV Capacitor-Bank Design Protection & Testing

Optimizing HV Capacitor-Bank Design Protection & Testing Optimizing HV Capacitor-Bank Design Protection & Testing Benton Vandiver III ABB Inc. 71st Annual Conference for Protective Relay Engineers Texas A&M University Introduction Shunt Capacitor Bank Considerations

More information

Power Factor. Power Factor Correction.

Power Factor. Power Factor Correction. Power Factor. Power factor is the ratio between the KW and the KVA drawn by an electrical load where the KW is the actual load power and the KVA is the apparent load power. It is a measure of how effectively

More information

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS

NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS NOVEL PROTECTION SYSTEMS FOR ARC FURNACE TRANSFORMERS Ljubomir KOJOVIC Cooper Power Systems - U.S.A. Lkojovic@cooperpower.com INTRODUCTION In steel facilities that use Electric Arc Furnaces (EAFs) to manufacture

More information

Design Specifications Low Voltage Active Harmonic Filter

Design Specifications Low Voltage Active Harmonic Filter Design Specifications Low Voltage Active Harmonic Filter 1.0 General Description This section contains the design standards, general equipment type and configuration, components, product description, warranty

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale For Substation Capacitor Banks and Shunt Reactors Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified by the SPE CIAL

More information

Insulation Co-ordination For HVDC Station

Insulation Co-ordination For HVDC Station Insulation Co-ordination For HVDC Station Insulation Co-ordination Definitions As per IEC 60071 Insulation Coordination is defined as selection of dielectric strength of equipment in relation to the operating

More information

Power Quality Solutions

Power Quality Solutions Power Quality Solutions What is Power Quality? For electrical systems to function in their intended manner without significant loss of performance or life, they require a supply of electricity that is

More information

Automatic capacitor banks with detuned filters

Automatic capacitor banks with detuned filters Power factor correction and harmonic filtering 5 R. /6 Automatic capacitor banks with detuned filters R. 5 /6 Automatic capacitor banks with detuned filters Introduction R5/6-3 R.5 - Automatic capacitor

More information

Connection Impact Assessment Application

Connection Impact Assessment Application Connection Impact Assessment Application This form is for generators applying for Connection Impact Assessment (CIA) and for generators with a project size >10 kw. Please return the completed form by email,

More information

Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering

Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering Impacts of the Renewable Energy Resources on the Power System Protection by: Brent M. Fedele, P.E., National Grid for: 11 th Annual CNY Engineering Expo - Nov. 3, 2014 Index Normal Distribution System

More information

McGill Power Sales & Engineering, INC.

McGill Power Sales & Engineering, INC. 1 McGill Power Sales & Engineering, INC. Power Factor Correction Terry McGill President McGill Power Sales & Engineering Inc. 2007 Eaton Corporation. All rights reserved. Agenda What is power factor? What

More information

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard Generation and Load Interconnection Standard Rev. 0A DRAFT Name Signature Date Prepared: Approved: VP Acceptance APEGGA Permit to Practice P-08200 TABLE OF CONTENTS 1.0 INTRODUCTION...5 1.1 Purpose...5

More information

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering) R10 Set No. 1 Code No: R41023 1. a) Explain how arc is initiated and sustained in a circuit breaker when the CB controls separates. b) The following data refers to a 3-phase, 50 Hz generator: emf between

More information

Table of Contents. Introduction... 1

Table of Contents. Introduction... 1 Table of Contents Introduction... 1 1 Connection Impact Assessment Initial Review... 2 1.1 Facility Design Overview... 2 1.1.1 Single Line Diagram ( SLD )... 2 1.1.2 Point of Disconnection - Safety...

More information

Protection of Electrical Networks. Christophe Prévé

Protection of Electrical Networks. Christophe Prévé Protection of Electrical Networks Christophe Prévé This Page Intentionally Left Blank Protection of Electrical Networks This Page Intentionally Left Blank Protection of Electrical Networks Christophe Prévé

More information

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics Reactive Power and Harmonic Compensation Guide to Harmonics POWER QUALITY The Basics of Harmonics All business types, commercial, industrial, government and energy/utility have a concern with power quality.

More information

thepower to protect the power to protect i-gard LITERATURE Low and medium voltage

thepower to protect  the power to protect i-gard LITERATURE Low and medium voltage thepower to protect i-gard LITERATURE Low and medium voltage distribution systems Arc Flash Hazards and High Resistance Grounding Grounding of Standby and Emergency Power Systems Neutral Grounding Resistors

More information

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation

4. CAPACITIVE VOLTAGE TRANSFORMERS AND COUPLING CAPACITORS Oil-paper insulation 4. CPCITIVE VOLTGE TRNSFORMERS ND COUPLING CPCITORS 420 kv Capacitive voltage transformers. Fingrid, Visulahti (Finland). 34 Instrument transformers High voltage INTRODUCTION Capacitive voltage transformers

More information

Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions

Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions PQ20 June 16-18, 2010 Kuressaare Experimental Investigations and Calculations in 6-35 kv Networks with Various Neutral Conditions A. Shirkovets, A. Vasilyeva, A. Telegin LLC BOLID, Novosibirsk, Russia

More information

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW ELECTRIC UTILITY CONTACT INFORMATION Consumers Energy Interconnection Coordinator 1945

More information

Embedded Generation Connection Application Form

Embedded Generation Connection Application Form Embedded Generation Connection Application Form This Application Form provides information required for an initial assessment of the Embedded Generation project. All applicable sections must be completed

More information

Improving the Power Factor Correction in the Presence of Harmonics by Reducing the Effect of Resonance and Harmonics

Improving the Power Factor Correction in the Presence of Harmonics by Reducing the Effect of Resonance and Harmonics Indonesian Journal of Electrical Engineering and Computer Science Vol. 3, No. 2, August 2016, pp. 282 ~ 295 DOI: 10.11591/ijeecs.v3.i2.pp282-295 282 Improving the Power Factor Correction in the Presence

More information

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY -- D.,.,.,. E S C R I P T I V E B U L L E T I N Bulletin DB-106 Square D Company October, 1990 ---1 I SQU ARED COMPANY -- Electrical Power Distribution System - The Heart of the Business From small commercial

More information

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network Preface p. iii Introduction and General Philosophies p. 1 Introduction p. 1 Classification of Relays p. 1 Analog/Digital/Numerical p. 2 Protective Relaying Systems and Their Design p. 2 Design Criteria

More information

Great Northern Transmission Line: Behind the (Electrical) Design

Great Northern Transmission Line: Behind the (Electrical) Design Great Northern Transmission Line: Behind the (Electrical) Design November 8, 2017 Christian Winter, P.E. Minnesota Power Sivasis Panigrahi, P.E. POWER Engineers, Inc. What is the Great Northern Transmission

More information

Capacitive voltage transformers

Capacitive voltage transformers Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550

More information

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc. 770 565-1556 John@L-3.com 1 Protection Fundamentals By John Levine 2 Introductions Tools Outline Enervista Launchpad

More information

Presents. Harmonics Years

Presents. Harmonics Years Presents Harmonics What is a Harmonic? A harmonic is the term used for current flow on your facilities power system at frequencies other than 60Hertz. Harmonic Problems Include: Harmonic Problems

More information

Multimeter 500CVD21 RTU500 series

Multimeter 500CVD21 RTU500 series Remote Terminal Units - Data sheet Multimeter 500CVD21 RTU500 series CT/VT interface with 4 voltage and 24 current inputs for direct monitoring of 3/4 wire 0 300 V AC (line to earth), 0...500 V AC (phase

More information

ARC FLASH HAZARD ANALYSIS AND MITIGATION

ARC FLASH HAZARD ANALYSIS AND MITIGATION ARC FLASH HAZARD ANALYSIS AND MITIGATION J.C. Das IEEE PRESS SERIES 0N POWER ENGINEERING Mohamed E. El-Hawary, Series Editor IEEE IEEE PRESS WILEY A JOHN WILEY & SONS, INC., PUBLICATION CONTENTS Foreword

More information

Harmonic Filters for Single Phase Equipment

Harmonic Filters for Single Phase Equipment POWER QUALITY Harmonic Filters for Single Phase Equipment Agriculture Call Centers Casino Slot Machines Computer Centers Distributed Generation Electronic Power Converter Oil & Gas On-Line UPS Power Electronics

More information

Catastrophic Relay Misoperations and Successful Relay Operation

Catastrophic Relay Misoperations and Successful Relay Operation Catastrophic Relay Misoperations and Successful Relay Operation Steve Turner (Beckwith Electric Co., Inc.) Introduction This paper provides detailed technical analysis of several catastrophic relay misoperations

More information

Automatic capacitor banks with detuned filters

Automatic capacitor banks with detuned filters الکتروه م ند Power factor correction and harmonic filtering Automatic capacitor banks with detuned filters www.electrohamand.com Automatic capacitor banks with detuned filters Introduction R5/6-3 R.5 -

More information

Ferroresonance Conditions Associated With a 13 kv Voltage Regulator During Back-feed Conditions

Ferroresonance Conditions Associated With a 13 kv Voltage Regulator During Back-feed Conditions Ferroresonance Conditions Associated With a Voltage Regulator During Back-feed Conditions D. Shoup, J. Paserba, A. Mannarino Abstract-- This paper describes ferroresonance conditions for a feeder circuit

More information

Generation and Load Interconnection Standard

Generation and Load Interconnection Standard Generation and Load Interconnection Standard Rev. 0 DRAFT Name Signature Date Prepared: Approved: VP Acceptance APEGGA Permit to Practice P-08200 TABLE OF CONTENTS 1.0 INTRODUCTION...5 1.1 Purpose...5

More information

Problems connected with Commissioning of Power Transformers

Problems connected with Commissioning of Power Transformers Problems connected with Commissioning of Power Transformers ABSTRACT P Ramachandran ABB India Ltd, Vadodara, India While commissioning large Power Transformers, certain abnormal phenomena were noticed.

More information

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau

Reactive Power Control Relay RM 2106 / 2112 Operating Instructions. FRAKO Kondensatoren- und Anlagenbau Reactive Power Control Relay RM 2106 / 2112 Operating Instructions FRAKO Kondensatoren- und Anlagenbau www.frako.com Figure 1 Front view a b c d e Display for active capacitor stages Display for inductive

More information

Onsite Mobile AC High Voltage Test System

Onsite Mobile AC High Voltage Test System TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument

More information

Power Quality Symptoms What Is Normal? Power Quality Approach. Other Power Quality Solutions

Power Quality Symptoms What Is Normal? Power Quality Approach. Other Power Quality Solutions April 25, 2017 Mike Carter Power Quality Symptoms What Is Normal? Power Quality Approach Find and fix Ride-through Solutions Protection/Compensation Schemes Other Power Quality Solutions What Can Go Wrong?

More information

1% Switchgear and Substations

1% Switchgear and Substations 1% Switchgear and Substations Switchgear and substations are not always matters of concern for transmitter designers, -because they are often part of the facilities of a typical installation. However,

More information

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS

OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS OPERATING, METERING, AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 2,000 KILOWATTS CONNECTED TO THE DISTRIBUTION SYSTEM ORANGE AND ROCKLAND

More information

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider Shunt Reactors Global Top Energy, Machinery & Plant Solution Provider Our Business Brief introduction of Hyosung Power & Industrial Systems PG While Hyosung is an established name for world-class electrical

More information

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications: SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument

More information

Solving Customer Power Quality Problems Due to Voltage Magnification

Solving Customer Power Quality Problems Due to Voltage Magnification PE-384-PWRD-0-11-1997 Solving Customer Power Quality Problems Due to Voltage Magnification R. A. Adams, Senior Member S. W. Middlekauff, Member Duke Power Company Charlotte, NC 28201 USA E. H. Camm, Member

More information

Capacitive voltage transformers

Capacitive voltage transformers Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550

More information

P2 Power Solutions Pvt. Ltd.

P2 Power Solutions Pvt. Ltd. P2 Power Solutions Pvt. Ltd. An ISO 9001:2008 Company Active Current Conditioners P2 Power Solutions Pvt. Ltd. P2 Power Solutions works to deliver Innovative Engineering solutions with specific focus on

More information

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks

RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks RAP Ripple Control Coupling for parallel injection of RC signals in Medium and High Voltage Networks We reserve all rights to this document, and the subject-matter it deals with. Duplication, dissemination

More information

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter

Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter 1 Design, Control and Application of Modular Multilevel Converters for HVDC Transmission Systems by Kamran Sharifabadi, Lennart Harnefors, Hans-Peter Nee, Staffan Norrga, Remus Teodorescu ISBN-10: 1118851560

More information

Active Harmonic Filter

Active Harmonic Filter Reactive Power and Harmonic Compensation Active Harmonic Filter The new StacoSine Plus active harmonic filter is available in 100, 150, 200 and 300 amp assemblies. Modules can be paralleled for a maximum

More information

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application

Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application General Application Information Remotes Case 2&3 Form REINDEER Cases 2&3 -Connection Impact Assessment (CIA) Application Hydro One Remote Communities Inc. Lori.Rice@hydroone.com 1-807-474-2828 This Application

More information

Power Quality Basics. Presented by. Scott Peele PE

Power Quality Basics. Presented by. Scott Peele PE Power Quality Basics Presented by Scott Peele PE PQ Basics Terms and Definitions Surge, Sag, Swell, Momentary, etc. Measurements Causes of Events Possible Mitigation PQ Tool Questions Power Quality Measurement

More information

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS

DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS DETUNED INDUCTORS FOR PF IMPROVEMENT CAPACITORS Electrical supply systems harmonics is like a cancer on supply systems and causes extreme bad effects on the supply system component and connected electrical

More information

Reactive Energy Management

Reactive Energy Management Energy management Reactive Energy Management Low Voltage Components Catalogue 2010 Reactive Energy Management Main contents Power Factor Correction guideline 2 Low Voltage capacitors 3-9 Detuned reactors

More information

Level 6 Graduate Diploma in Engineering Electrical Energy Systems

Level 6 Graduate Diploma in Engineering Electrical Energy Systems 9210-114 Level 6 Graduate Diploma in Engineering Electrical Energy Systems Sample Paper You should have the following for this examination one answer book non-programmable calculator pen, pencil, ruler,

More information

Babak Enayati National Grid Thursday, April 17

Babak Enayati National Grid Thursday, April 17 2014 IEEE PES Transmission & Distribution Conference & Exposition Impacts of the Distribution System Renewable Energy Resources on the Power System Protection Babak Enayati National Grid Thursday, April

More information

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web: Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Technical Reference Capstone MicroTurbine Electrical Installation 410009 Rev F (October 2013) Page 1 of 31 Capstone Turbine Corporation

More information

AC Resonant Test Systems Tank Type Up to 500 kv

AC Resonant Test Systems Tank Type Up to 500 kv R AC Resonant Test Systems Tank Type Up to 500 kv PHENIX TECHNOLOGIES Testing Applications High power AC Resonant Test Systems are used where the load is largely capacitive with very low real power losses

More information