1 kilform civil product range ESB CCTV Eircom Services Lighting Risers DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully Headwalls Gully Risers Cast Iron Free Flow Lids MARKER POSTS, SLABS AND PLATES Round Top Marker Post Flat Top Marker Post Square Head Marker Post Electrical Marker Post MISCELLANEOUS Retaining Wall Blocks Lamp Post Base Duct Marker Post Duct Marker Blocks Hydrant and Water Plates Earth Rod Box Specials made to order
2 REFERENCE SIZE MM A x B x C HOLES 4 WAY HOLES 3 WAY HOLES 2 WAY HOLES KNOCK OUT STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply with EN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced. WEIGHT KG J/B x 1110 x J/B x 1110 x J/B x 1270 x J/B x 590 x J/B x 590 x J/B x 540 x J/B x 850 x J/B x 1450 x J/B x 1150 x J/B x 1450 x J/B x 700 x J/B x 1600 x J/B x 1310 x J/B x 1210 x J/B x 1210 x J/B x 1210 x J/B x 1150 x J/B x 950 x J/B x 1400 x J/B x 1110 x J/B x 1150 x
3 COLOUR CODE BURIED PLASTIC PIPING I.S. 370: 2007 Electricity ducting Public lighting Street furniture / signal below 125 Volt Gas pipe Buried potable water Sewer Storm and road drain smooth external wall duct Storm and road drain corrugated Telecom / fibre optic smooth external wall duct Telecom / fibre optic corrugated dud only- Maximum pipe outside diameter 175 mm Any colour except Red or Yellow Junction Boxes Section ***Colour may very depend on application STANDARDS NOTICE: Killeshal Precast Services Boxes are manufactured to comply with EN1917:2004 Concrete manholes and inspection chambers unreinforced, steel fibre and reinforced. eircom JUNCTION BOX 3 eircom JUNCTION BOX x 1110 x 800mm 640 x 1110 x 800mm Other sizes available contact Killeshal s customer service on Ref: eircom J/B 3 Reinforced walls. eircom approved. Ref: eircom J/B 4 Easily knockout polystyrene cable entry point/can be supplied with 12/no x 150mm dia straight through entry points (4/no or 1. no side wall, 4/no on each cable end). Easily manoeuvred with lifting eyes. eircom JUNCTION BOX 28 eircom JUNCTION BOX x 1210 x 900mm 740 x 1210 x 900mm Ref: eircom J/B 28 Ref: eircom J/B 29 3
4 ESB MINI PILLAR JUNCTION BOX x 1270 x 895mm Reinforced walls. 100 mm shoulder to facilitate increasing the depth. Drainage Sump. Easily manoeuvred. Multiple cable entry points. Integrated, reinforced base. 450 x 700 x 650mm Ref: J/B 5*** JUNCTION BOX 24 JUNCTION BOX 9 JUNCTION BOX 10 JUNCTION BOX 11 HEAVY DUTY VALVE CHAMBER 440 x 590 x 400mm HEAVY DUTY VALVE CHAMBER 440 x 590 x 200mm Ref: J/B 10 Ref: J/B 9 Ref: J/B 24*** 420 x 540 x 220mm Ref: J/B 9 Ref: J/B 10 Ref: J/B 11 JUNCTION BOX 12 JUNCTION BOX 15 JUNCTION BOX 18 JUNCTION BOX 21 MANHOLE BOX 850 x 850 x 950mm MANHOLE BOX 890 x 1490 x 950mm MANHOLE BOX 1150 x 1150 x 850mm MANHOLE BOX 1150 x 1450 x 850mm Frame Ref: J/B 13 Frame Ref: J/B 16 Frame Ref: J/B 19 Frame Ref: J/B 22 Ref: J/B 12 Ref: J/B 15 Ref: J/B 18 Ref: J/B 21 Base Ref: J/B 14 Base Ref: J/B 17 Base Ref: J/B 20 Base Ref: J/B 23 ***Colour may very depend on application see page 2 4
5 1000 x 1600 x 1040mm JUNCTION BOX 25 Reinforced concrete walls. Preformed cable entry points. Integrated reinforced base. Base incorporating sump. Easily manoeuvred with lifting hooks. Ironmongery fitted. For J/B 25 without base see J/B 33 Ref: J/B 25*** NRA RCD/500/54 JUNCTION BOX x 1310 x 1150mm Reinforced concrete walls. Preformed cable entry points. Integrated reinforced base. Splayed base to aid stability. Easily manoeuvred. Base incorporating sump x 1210 x 870mm Ref: J/B 26*** JUNCTION BOX 27 For J/B 26 without base see J/B 34 High adjusting riser to suit see J/B 502 For J/B 27 without base see J/B 35 High adjusting riser to suit see J/B 502 SUBGRAGE DBR % TABLE FOR J/B 25, J/B 26, J/B 27 BLINDING AND EMBEDDING REQUIREMENTS IN ACCORDANCE WITH HD 25/95 SUB-BASE THICKNESS MM Ref: J/B 27*** EDGE DISTANCE FROM BOX TO EDGE BLINDING MM SUB-BASE MATERIAL > GRANULAR MATERIAL (TYPE2) 5<CBR< GRANULAR MATERIAL (TYPE2) 3<CBR< GRANULAR MATERIAL (TYPE2) < MM OF CAPPING (6F1 OR 6F2) OVERLAID BY A GRANULAR SUB-BASE (TYPE2) UP TO 400MM IF REQUIRED ***Colour may very depend on application see page 2 5
6 800 x 1400 x 895mm For J/B 33 with base see J/B 25 High adjusting riser to suit see J/B 502 JUNCTION BOX x 1110 x 1000mm JUNCTION BOX 34 Ref: J/B 33*** For J/B 34 with base see J/B 26 High adjusting riser to suit see J/B 502 JUNCTION BOX 31 JUNCTION BOX x 950 x 900mm 1075 x 1150 x 1050mm For J/B 31 with base see J/B x 1150 x 1050mm For J/B 35 with base see J/B 27 High adjusting riser to suit see J/B 502 JUNCTION BOX 35 For J/B 30 without base see J/B 31 Ref: J/B 34*** Ref: J/B 35*** High adjusting riser to suit see J/B 501 High adjusting riser to suit see J/B 501 Ref: J/B 31*** Ref: J/B 30*** JUNCTION BOX RISER J/B 501 JUNCTION BOX RISER J/B x 950 x 150mm Riser if required - J/B 31 for high adjustment - J/B x 1110 x 100mm Riser if required - J/B 26 for high adjustment - J/B 27 - J/B 34 - J/B 35 Ref: J/B 501 Ref: J/B 502 ***Colour may very depend on application see page 2 6
7 370 x 490 x 610mm DUCT CHANNEL 105 DUCT CHANNEL 108 DUCT COVER Ref: D/C x 285 x 915mm DUCT COVER Ref: D/C 126 Ref: D/CH 105 DUCT CHANNEL 111 DUCT CHANNEL x 765 x 1497mm 340 x 448 x 1000mm DUCT COVER Ref: D/C 209 Ref: D/CH 108 DUCT CHANNELS AND COVERS Ref: D/CH 111 DUCT CHANNEL 114 DUCT CHANNEL x 440 x 1000mm 170 x 280 x 1000mm DUCT COVER Ref: D/C 260 SPILLWAY CHANNEL to 450 x 710 x 895 x 1000mm Ref: D/CH 114 DUCT COVER Ref: D/C x 1037 x 2000mm HEADWALLS Ref: D/CH 117 Ref: D/CH 115 Other sizes available contact Killeshal s customer service on Ref: D/CH 116 GAS LINE COVER SLABS 1450 x 100mm 1450 x 150mm 1450 x 200mm Ref: M/127 Ref: D/C 242 Ref: D/C 199 Ref: D/C 228 7
8 UNTRAPPED GULLY UNTRAPPED GULLY (800x380x445mm) Ref: G/1 Ref: G/1 + G/R 104 TRAPPED GULLY TRAPPED GULLY (800x500x375mm) Ref: G/1 + G/R C/250 (G/9) ROAD GULLY AND LIDS Ref: G/2 Ref: G/2 + G/R 104 LARGE TRAPPED GULLY LARGE TRAPPED GULLY (805x585x450mm) Ref: G/2 + G/R C/250 (G/9) 970x970x85mm 750x650x100mm - G/5 Ref: G/5 GULLY RISERS 750x650x100mm - G/5 Ref: G/5 + Ref: G/5 + G/R C/250 (G/9) G/R C/400 (G/10) 610x610x100mm - G/1 - G/2 CAST IRON FREE FLOW LIDS 527x527x100mm - G/5 515x395x75mm - G/1 - G/2 - G/5 Ref: G/R 101 Ref: G/R 102 Ref: G/R 103 Ref: G/R 104 Ref: D/400 (G/10) Ref: D/250 (G/9) 8
9 MARKER POSTS AND SLABS marker posts are placed at or behind location points for services such as AV/SV, hydrant chambers, water and gas chambers, electric cable junctions and field markers as markers for emergency services or service engineers buried hazard warning marker slabs which shadow electricity lines and gas pipes, helping to avoid breaches and health and safety incidents ROUND TOP (300x100x1090mm) *Plates see below FLAT TOP (270x80x1220mm) *Plates see below SQUARE HEAD (75x100x1230mm) *Plates see below DUCT (110x140x1600mm) MARKER POSTS & PLATES DUCT MARKER BLOCK (300x300x225mm) Ref: M/POST 101 Ref: M/POST 102 Ref: M/POST 116 Ref: M/POST 111 ELECTRICAL (180x50x935mm) DUCT MARKER BLOCK (300x300x225mm) DUCT MARKER BLOCK (300x300x225mm) Ref: M/POST 105 EARTH ROD BOX (325x325x150mm) Ref: M/POST 113 Ref: M/POST 114 Ref: M/POST 115 HYDRANT PLATES *Made to suit each individual requirements PLATES WATER PLATES *Full range of plates available Ref: M/123 MISCELLANEOUS RETAINING WALL BLOCKS 1400 x 695 x 795mm Ref: M/112 LAMP POST BASE 700 x 700 x 700mm * 1200 x 1200 x 1200mm also available Ref: IR/11 For Line Drainage See Pre-Fabricated Drainage System Catalogue 9
10 UK OFFICE Tel: Web: killeshalprecast.co.uk R. I OFFICE Tel: +353 (0) sales@killeshal.com Web: killeshal.com
MANHOLES PART I: GENERAL. A. Precast Concrete Manholes
MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a
More informationEngineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings
Engineering and Construction Services Division Construction Drawings for Sewers and Watermains Revision No. 8 April All T drawings New title block for each drawing is now standardized. Revision numbers
More informationSTANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN
CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D ASPHALT 20 GUTTER LINE CONCRETE CURB FINISHED GRADE PRECAST GRADE RINGS, 2 50 100 MAX PRECAST CB LID GROUT ALL AROUND CB LEAD, INSIDE & OUTSIDE OF
More informationABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing
ABOUT INLAND Inland roots in the Winnipeg area date back to the early 960 s. Over time, through a number of mergers and acquisitions Inland Pipe is now part of the Lehigh Hanson group in North America
More informationDESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA
DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA 94544-1395 PUBLIC WORKS DESIGN GUIDELINES TABLE OF CONTENTS SD-100 SERIES SPECIAL DRAWINGS SD-100 8/1991 SILT
More informationCooke Precast Concrete
Cooke Precast Concrete History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience within the precast
More informationPipe Product Catalog Table of Contents
Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"
More informationCooke Precast Concrete
Cooke Precast Concrete INSPECTION OPENINGS History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience
More informationManhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard
More information2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard
More informationStandard Specifications
Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and
More informationStandard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.
DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard
More informationTIMARU DISTRICT COUNCIL 2 King George Place P.O. Box 522 Timaru 7940 Telephone: Website:
INITIAL SURVEY ILE: CHANGES TO CORBEL DETAIL REVISION BY CHK APP. PLANNING.dwg 711696 AS SHOWN PERMISSION O THE CODE O PRACTICE TYPICAL PRECAST CONCRETE MANHOLE DETAILS 1 13 A B INITIAL SURVEY ILE: CHANGES
More informationDIVISION APPROVED MATERIAL LIST AND STANDARD DETAILS
DIVISION 400 - APPROVED MATERIAL LIST AND STANDARD DETAILS Section 403 - STANDARD DETAILS TABLE OF CONTENTS DIVISION 400, Section 403 - STANDARD DETAILS SECTION DETAIL NOS. Application Table 403-1 I. Concrete
More informationSUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-01) MANUAL: Standard
More informationCity of Vaughan Engineering Department DESIGN STANDARD DRAWINGS
City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS March 2004 STANDARD DRAWINGS Partners With The Environment March 2004 FORWARD The March 2004 version of the City of Vaughan Design Standard
More informationC-M TMR Products Index
C-M TMR Products Index TMR Dwg. No. Grate/Frames 9x6 Dwg. AS3996 Recessed Road Gully Units Dwg. 1443, 1444 Protruded Road Gully Units Dwg. 1443, 1444 1220 Road Gully Units Dwg. 1459 7x4 Road Gully Units
More informationINSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September
More informationSUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-03) MANUAL: Standard
More informationTOWN of LAKESHORE SITE PLAN CHECKLIST
TOWN of LAKESHORE SITE PLAN CHECKLIST Last Revised December 17, 2009 Project Name: Project Location: Date Submitted: Name Phone Number E-mail Address Owner: Contractor/ Engineer: ( ) ( ) Applicant: ( )
More informationSUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard
More informationMSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY
MSD M etr o p olitan S e w e r Di s t r ict STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY 40203-1911 STANDARD DRAWINGS DIVISION
More informationPART 4 STANDARD DRAWINGS FOR CONSTRUCTION
4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of
More informationSUPPLEMENTARY STANDARD DETAIL DRAWINGS
CITY OF MAPLE RIDGE DESIGN AND CONSTRUCTION DOCUMENTS Part 4 SUPPLEMENTARY STANDARD DETAIL DRAWINGS September 2015 Updated: October 2015 THIS PAGE INTENTIONALLY LEFT BLANK City of Maple Ridge Supplementary
More informationSECTION ELECTRICAL IDENTIFICATION
SECTION-16075 ELECTRICAL IDENTIFICATION PART 1 GENERAL 1.01 SECTION INCLUDES A. Electrical identification to identify all electrical items for easy operation and maintenance including, but not limited
More informationSECTION MANHOLES
SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard
More informationCooke Precast Concrete
Cooke Precast Concrete STORMWATER History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience within
More informationCONCRETE MANHOLES.
CONCRETE CONCRETE SHAW PIPE produces circular, precast, concrete manholes in diameters 1050mmØ through 3000mmØ. Precast, concrete manholes are most frequently used for pipeline and sewer entry and are
More informationMH Table of Contents Standard Title/Scope Page Table of Contents SCE Public
MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................
More informationManholes Table of Contents
Standard MH 300 Title Manholes Requirements MH 300.1 Manholes Requirements Manholes Table of Contents Underground Structures Standards MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Precast Tub-Type
More informationSECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS
UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS 8.01 - Page i UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS Table of Contents SECTION
More informationSECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings
SECTION 095 SPECIFICATIONS DETAIL DRAWINGS Index of Detail Drawings Flat Top Manhole... 095-1 Splash Drop Manhole and Regular Drop Manhole... 095-2 Special Detail Splash Drop Manhole and Special Detail
More informationSTATE WHEN ORDERING HI =...
STATE WHEN ORDERING HI =... mm Surface treatment of outer walls and night closing doors Stainless steel cladding Special anodized... RAL... Special powder coating...... Surface treatment of door leaves
More informationRisk Assessment & Safe Working Practice
RA Ref Number: 36 Revision: 3 Project/Job Number Reference Insert Job Number Approval Date: 30/03/2018 RA Description: Installing Trunking Next Review Date: 01/04/2019 Notes: Please refer to Safe Working
More informationSECTION 39 - MANHOLES TABLE OF CONTENTS
SECTION 39 - MANHOLES TABLE OF CONTENTS Section Page 39-1 GENERAL... 39.1 39-2 PRECAST CONCRETE MANHOLES... 39.1 39-2.01 Precast Concrete Sewer Manholes... 39.1 39-2.02 Precast Concrete Storm Drain Manholes...
More informationREGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE
No. 9197 REGISTRATION EXAMINATION, JUNE 2008 DRAINLAYING ANSWER SCHEDULE Plumbers, Gasfitters and Drainlayers oard, 2008. All rights reserved. No part of this publication may be reproduced by any means
More informationMAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX
407-1 - MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1.1 GENERAL Tender Items Specifications Standard Drawings 407-1.1.1 Frame and Grate Selection 407-1.1.2 Selection of Structure
More informationSTORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC
01-APR-2015 13:33 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\stm_det01_8x11_st01.dgn TIME = MIN 3 CRSES MAX 5 CRSES 3 OR 3.5 PRECAST ECCENTIC CONC ID PIPE GRADE A CONC FILL 4" 8" 2-0"SUMP
More information24" Dia. 36" Dia. WE BUILD CONFIDENCE
WE BUILD CONFIDENCE WE BUILD CONFIDENCE PRECAST STRUCTURES SERVE AS KEY COMPONENTS OF OUR UTILITY AND TRANSPORTATION INFRASTRUCTURE. AND MAKING THE INDUSTRY S BEST PRECAST PRODUCTS TAKES DEDICATION, ATTENTION
More informationSTANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018
SYMBOLS STANDARD DRAWINGS INDEX No Statewide Standard - Use Regional A3 Legend Detail Sheet BRIDGE AND STRUCTURES B-08.00 Bin Walls 1 CONSTRUCTION-BARRICADES AND SIGNING C-04.12 Location of Double Traffic
More informationCablelink Plus Flush Technical
Cablelink Plus Flush Technical 107 technical hotline +44 (0)1268 563720 screeded floor systems is designed to provide power and data distribution highways in screeded floors. The robust system offers a
More informationSOUTH AFRICAN NATIONAL STANDARD
ISBN 978-0-626-27370-5 SOUTH AFRICAN NATIONAL STANDARD Precast concrete manhole sections and components Published by SABS Standards Division 1 Dr Lategan Road Groenkloof Private Bag X191 Pretoria 0001
More informationMiscellaneous. Demolition
Public Improvements Miscellaneous 1 Mobilization L.S. ** 2 Clearing and Grubbing L.S. *** 3 Structural Concrete Incl. Reinforcing C.Y. $1,325.00 4 6" PVC Sleeves L.F. $26.00 Demolition 5 Remove Asphalt
More informationSECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS
9. STANDARD DETAILS SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a
More informationGovernment Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications
PAGE NO. : 1 OF 4 Revision Date: July 2009 STANDARD DRAWINGS TABLE OF CONTENTS DRAWING # DESCRIPTION 0030............ Work Adjacent to Roadway 0040............ Work at the Edge of Roadway 0050............
More informationAnti-Trust Statement
Anti-Trust Statement http://www.concrete-pipe.org/ A joint effort of the Texas Concrete Pipe Association and the Texas Department of Transportation What brought this about? The TxDOT organization consists
More informationSTANDARD AND EXAMPLE DRAWINGS
STANDARD AND EXAMPLE DRAWINGS DRAWING ISSUE TITLE GENERAL CA01-1-1 E EXAMPLE CATCHMENT PLAN - DESIGN BASIS CA01-1-2 D EXAMPLE PRESSURE MAIN CHARACTERISTIC CURVE CA01-1-3-1 B TYPE 10, 40 AND 90 PUMPING
More informationAppendix C Construction Details
7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-04) MANUAL: Standard
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationRECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.
CELL: (715) 803-8009 MABOSI@WISCONSINPUBLICSERVICE.COM CELL: (715) 573-7806 CHVIRCKS@WISCONSINPUBLICSERVICE.COM CALVIN.KLADE@FTR.COM DGAU@KRONENWETTER.COM SCOTT OLSEN (715) 302-1348 S REVISED TO CONFORM
More informationCITY OF VISTA STANDARD DRAWINGS
CITY OF VISTA STANDARD DRAWINGS May, 2015 THIS SHEET INTENTIONALLY LEFT BLANK TABLE OF CONTENTS MODIFICATIONS Modifications to San Diego Regional Standard Drawings DRAINAGE STRUCTURES DRN 01 Corrugated
More informationUTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1
UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.
More informationUtility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles
Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. UTILITY STRUCTURES Perfect
More informationCITY OF VISTA STANDARD DRAWINGS
CITY OF VISTA STANDARD DRAWINGS May, 2015 THIS SHEET INTENTIONALLY LEFT BLANK TABLE OF CONTENTS MODIFICATIONS Modifications to San Diego Regional Standard Drawings DRAINAGE STRUCTURES DRN 01 Corrugated
More informationROOM smooth cement f.f FLOOR LAYOUT
3,300 3,600 4,100 2,159 1,000 1,241 ROOM smooth cement f.f 168 900 1,091 1,000 1,241 4,400 FLOOR LAYOUT FLOOR LAYOUT CARTAKERS ROOM 2,159 1,000 1,241 SOUTH ELEVATION EAST ELEVATION 1,241 1,000 1,091 900
More informationCONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION
ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01
More informationThe Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8
September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers
More informationBracket guide. LK Pipe Pole. LK Radiator fixture Uni
Bracket guide LK Radiator fixture Uni LK Radiator fixture Uni c/c 40 (Article no. 481 43 92) LK Radiator fixture Uni c/c 50 (Article no. 481 44 03) LK Pipe Pole (Article no. 481 43 91, 481 43 90) Used
More informationCustomer Connection Guide Updates Effective May 2017
This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services
More informationHollow Stem Auger Modifications
Hollow Stem Auger Modifications Auger Extensions Auger Extensions are used to compensate for the distance from the ground up to the rig. To order these extensions please specify: 1. Length: standards are
More informationkilform
kilform www.killeshal.com www.killeshalprecast.co.uk Stock sizes see page 6 Rep. Irl Tel: 057 9353018 Web: www.killeshal.com 3 TYPE C WINDOW SILL This window sill has a reduced seating and is the sill
More informationOakdale Primary School, Peterborough Civil Engineering NBS Specification
Oakdale Primary School, Peterborough Civil Engineering NBS Specification Prepared for Hamson Barron Smith Revision Schedule 171046 Civil Engineering NBS Specification May 2017 Rev Date Details Prepared
More informationLocator Accessories DATA SHEETS. Accessory Range for Pipe & Cable Location Equipment
Locator Accessories DATA SHEETS Accessory Range for Pipe & Cable Location Equipment GENERAL PURPOSE SONDE The C.SCOPE 8kHz and 33kHz General Purpose Sondes are transmitters used to trace the direction
More informationMETRIC LIGHTNING PROTECTION PRODUCTS
Section 11 Metric Description... Page # 11.1 Taper Pointed Air Rods, Air Terminals & Attachments...270 11.2 Saddles & Attachments...271-272 11.3 s...273-275 11.4 Attachments...276-279 11.5 Clamps...280
More informationG.J. FIRE HYDRANT BOX - TYPE 5 - SABS
G.J. FIRE HYDRANT BOX - TYPE 5 - SABS 558-1973 Material: SG Iron to BS. 1247 Replaces SABS Cast Iron Spec. All dimensions are in mm to SABS Spec. G.J. CIRCULAR VALVE BOX (Bell Toby) TYPE 3A - 3B - SABS
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (15-03) MANUAL: Standard
More informationKhathij Industrial Fasteners
Dear Sir/Madam, Khathij Industrial Fasteners This is Saqubar Sadique representing 'KHATHIJ INDUSTRIAL FASTENERS' from Chennai, India. We 'Khathij industrial fasteners' like to introduce us as a Stockist
More informationZ1035, Z1036, & Z1903 FLOOR DRAIN & CLEANOUT INSTALLATION STABILIZER
Z1035, Z1036, & Z1903 FLOOR DRAIN & CLEANOUT INSTALLATION STABILIZER The Zurn Drain Installation Stabilizer is a unique support plate designed to secure a drain in place and provide adjustment, rigidity,
More informationIntroduction. Classifications of piping: Industrial. Residential (i.e., plumbing) Carries liquids and gases used in the manufacture of products
Plumbing Plans Introduction Classifications of piping: Industrial Carries liquids and gases used in the manufacture of products Residential (i.e., plumbing) Carries fresh water, gas, liquid, solid waste
More informationTypical Drawings for Schools
0.85 1.7 0.85 3 3 0.6 3 3 0.85 1.7 0.85 0.3 4 4 1 1 2 2 0.425 0.425 0.425 0.425 1.2 2.4 1.2 0.6 0.6 4 4 1 1 3 3 0.4 0.6 0.3 0.3 3 3 4 4 0.4 4 4 1 1 2 2 Detail of (W 1.2 x 0.4 m) Detail of (W0.6 x 0.4 m)
More informationSECTION COMMON WORK RESULTS FOR HVAC
SECTION 23 05 00 COMMON WORK RESULTS FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball Valve. 2. Hangers and Supports. 3. Identification Tags and Sleeves. 1.2 INCLUDED SECTIONS A. Section
More informationM I N N E S O T A D O T BID TABULATION SUMMARY JOB PAGE 1 ON 01/14/97 MINNESOTA PROJECT NO.S: DPI 015-8(021) DPI 015-8(022)
BID TABULATION SUMMARY JOB 970010 PAGE 1 STATE PROJECT NO. 27-618-70 BIDS RECEIVED UNTIL 2:00 P.M. ON 01/14/97 MINNESOTA PROJECT NO.S: DPI 015-8(021) DPI 015-8(022) AT THE JUNCTION OF AUTO CLUB ROAD AND
More informationFootball Goals 7,32x2,44 m
Football Goals 7,32x2,44 m 120x100 mm Professional aluminum football goals 7,32x2,44 m Made of special oval aluminum profile 120x100 mm with double reinforcing ribs. The main frame of the goal powder coated
More informationnetball netball Socketed International Freestanding International Floor Fixed International Wheelaway Posts Practice Posts Rings
81 Socketed International Freestanding International Floor Fixed International Wheelaway Posts Practice Posts Rings Nets setting the standard - leading the field Official Suppliers of posts, nets and protectors
More informationEXCAVATION AND BACKFILL
Standard Specification 2565.3, 2451, and 1805 A basic understanding of specifications is needed to properly replace the disturbed soil and restore the condition of the excavated area. The size of the disturbed
More informationJunction boxes. Surface mounting - IP44 - IP55 - IP56 TECHNICAL CHARACTERISTICS
Junction boxes Surface mounting - IP44 - - IP56 TECHNICAL CHARACTERISTICS Technical specifications 3 models with cable outlets and snap fixed cover (IP44 according to Standards EN 60529) 7 models with
More informationB422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422
B422 - PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS - OPSS 422 422.1 GENERAL The work under these tender items consists of the fabrication and installation in open cut of precast reinforced
More informationRaised Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 Raised Floor system CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 10 3.Products détails 11 to 22 4.Technical characteristics
More informationSECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting
SECTION 33 71 19 UNDERGROUND POWER DUCT AND SUB-STRUCTURES PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 33: Trenching, Backfilling, and Compacting B. Section 32 01 00: Site Restoration and Rehabilitation
More informationStandard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (13-03) MANUAL: Standard
More informationSection E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02
Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing
More informationCSP PSYCHIATRIC SERVICES UNIT SECTION IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT
SECTION 23 05 53 IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pipe Markers. 2. Valve Tags. 3. Equipment Nameplates. 4. Underground Marking Tape. 5. Duct
More informationFlush Floor system LIMOGES Cedex. Phone : Fax :
87045 LIMOGES Cedex Phone : 05 55 06 87 87 Fax : 05 55 06 88 88 CONTENTS PAGES 1.Range 1 to 3 2.Installation process 4 to 8 3.Products détails 9 to 18 4.Technical characteristics 19 to 21 1 RANGE. Lid
More informationOutdoor equipment. Barrier posts. Stainless steel. Barrier elements. Barrier poles. Outdoor equipment - pages
- pages 215-228 Bicycle stands / lean-on hoops Laundry drying stands Tree guards Litter bins Planters 215 Bicycle rack Sturdy and space-saving due to alternating high and low racks. Racks can be bolted
More informationF-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg
Contents F-5-1a Concrete Bollards F-5-1b Concrete Bollards F-5-2 Concrete Bollards with City Logo F-5-3 Cast Iron Bollards F-5-4 Decorative Steel Bollard F-5-5 Swivel P Gate Steel Bollard F-5-6 Steel Bollard
More informationThru Wall Floor Seals For New Installation
The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or
More informationPlate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.
DISTRIBUTION: 7 MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Design Services Section TRANSMITTAL LETTER NO. (0-0) MANUAL: Standard Plates DATED: January 9, 00 SUBJECT:
More informationThis specification describes the minimum requirements for piping systems for the following service:
201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)
More informationIndustrial Pipe Marking
Industrial Pipe Marking Pipe and Valve Identification Specialists SPECIFICATIONS ASME (ANSI) Standard A13.1-2007 The ASME (ANSI) Standard for pipe identification is a widely used guideline in determining
More informationInternational Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS
International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies
More informationPiping & Equipment Identification
Piping & Equipment Identification Part 1 General 1.01 Description of Work A. Work in this section includes: Identification materials, including necessary accessories indicated on Contract Documents and
More informationSECTION TRACER WIRE FOR NONMETALLIC PIPE
PART 1 GENERAL 1.1 DESCRIPTION A. The CONTRACTOR shall furnish and install a conductive tracer wire with all buried plastic water mains, services and appurtenances in accordance with the Water Utilities
More informationMEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C
MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of
More informationPRODUCT CATALOGUE. Saskatchewan
PRODUCT CATALOGUE Saskatchewan From Cover Victoria Avenue (TransCanada Hwy ) is the primary entrance into the east side of Regina, SK and has over 40,000 vehicles per day travelling on it. The existing
More informationLETTING : CALL : 029 COUNTIES : GOODHUE
PAGE : -1 NUMBER OF DAYS: 80 BRIDGE COUNT : 2 CONTRACT DESCRIPTION : GRADING, SURFACING, LIGHTING AND BRIDGE NO. 25024. CONTRACT LOCATION: LOCATED ON T.H. 61 FROM 30' NORTH OF NORTH LAKESHORE DRIVE TO
More informationSECTION MANHOLES
SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.
More information6. Internal lightning protection
6. Internal lightning protection 6.1 Equipotential bonding for metal installations Equipotential bonding according to IEC 60364-4- 41 and IEC 60364-5-54 Equipotential bonding is required for all newly
More informationSECTION PRECAST CONCRETE SECTIONAL MANHOLES
SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,
More informationWiring ducts Easily allows for organization, pulling and separation of cables
Easily allows for organization, pulling and separation of cables 2 Catalogue Wiring ducts I ABB Index Halogen free wiring ducts with vertical slots 4 Thermoplastic wiring ducts with vertical slots Flexible
More information