Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Size: px
Start display at page:

Download "Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles"

Transcription

1 Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions.

2 UTILITY STRUCTURES Perfect for counications, electrical, gas or steam systems, precast concrete utility structures protect the vital connections and controls for utility distribution. Precast concrete is nontoxic and environmentally safe. It resists buoyancy, making it an ideal material for use in all underground applications. Products include: hand holes, hollowcore products, light pole bases, meter boxes, panel vaults, pull boxes, telecounications structures, transformer pads, transformer vaults, trenches, utility buildings, utility vaults, utility poles, controlled environment vaults (CEVs) and other utility structures. REVISED March 14, SHAw precast solutions UTILITY, POWER, and COMMUNICATION

3 10 X 2700 X 2100 UTILITY VAULT 3048 Access configuration as specified Pipe connections to suit Double Ram- Nek Gasket Joint UTILITY VAULTS Optional sump TYPICAL COVER LONGITUDINAL SECTION Pipe connections to suit Optional sump TYPICAL BASE TRANSVERSE SECTION SHAw precast solutions UTILITY STRUCTURES > UTILITY VAULTS 3

4 1800 X 3600 X 2000 UTILITY VAULT 3962 Access configuration as specified UTILITY VAULTS Access opening as specified 2388 Double Ram-Nek Gasket Joint Pipe connections to suit Optional sump TYPICAL COVER LONGITUDINAL SECTION Pipe connections to suit Optional sump 1829 REVISED March 14, TYPICAL BASE TRANSVERSE SECTION 4 SHAw precast solutions UTILITY STRUCTURES > UTILITY VAULTS

5 3000 x 3600 x 2100 UTILITY VAULT 4064 Access configuration as specified Access opening as specified 2540 Double Ram-Nek Gasket Joint Pipe connections to suit Optional sump UTILITY VAULTS LONGITUDINAL SECTION TYPICAL COVER Pipe connections to suit TRANSVERSE SECTION Optional sump TYPICAL BASE SHAw precast solutions UTILITY STRUCTURES > UTILITY VAULTS 5

6 TYPICAL CONFIGURATION FOR UNDERGROUND TELEPHONE AND ELECTRICAL DUCTS R 90 FRAME AND COVER RAM-NEK GASKET "H" SECTION UTILITY VAULTS BELL END CONNECTORS FOR DUCT PENETRATIONS 12 THREADED INSERTS CAST IN SIDE WALLS FOR CABLE RACKS CABLE PULLING IRON 400 X 400 SQR SUMP UNDERGROUND TELEPHONE AND ELECTRICAL DUCT CONFIGURATIONS ARE AVAILABLE FOR ALL SIZES OF UTILITY VAULTS REVISED March 14, SHAw precast solutions UTILITY STRUCTURES > UTILITY VAULTS

7 1800x3600 SWITCHING CUBICLES COVER SECTION A & B x3 OPENING c/w 25 ED EDGE R-90 FRAME & COVER CAST-IN BY SHAW PIPE º B A DUCT LOCATION, SIZE, OPENING TYPE TO BE SUPPLIED TO SHAW PRIOR TO FABRICATION 4064 SECTION A LONGITUDINAL SECTION 920 SWITCHING CUBICLES R-90 FRAME & COVER CAST-IN BY SHAW PIPE (TYP.) (TYP.) º DUCT LOCATION, SIZE, OPENING TYPE TO BE SUPPLIED TO SHAW PRIOR TO FABRICATION 1829 SECTION B TRANSVERSE SECTION 2045 SHAw precast solutions UTILITY STRUCTURES > SWITCHING CUBICLES 7

8 3000x3600 SWITCHING Cubicles COVER SECTION A & B R-90 FRAME & COVER 1700x3 OPENING CAST-IN BY SHAW PIPE c/w 25 ED EDGE SWITCHING CUBICLES REVISED March 14, Ø B A (TYP.) 402 (TYP.) 804 SECTION A LONGITUDINAL SECTION R-90 FRAME & COVER CAST-IN BY SHAW PIPE 1000 OPTIONAL SECTION SECTION B TRANSVERSE SECTION 762Ø 8 SHAw precast solutions UTILITY STRUCTURES > SWITCHING CUBICLES

9 ELECTRICAL POLE BASE THREE CONDUIT TYPE 1 GEOMETRY AND SECTION RIGID PVC CONDUIT FOR GROUND WIRE TYP A BASE DIAMETER AS REQ'D 152 TYP - GEOMETRY Ø HANDLING SLEEVE (100Ø CORED HOLE) SPIGOT RIGID PVC POWER CONDUIT ANCHOR BOLTS PROVIDED BY POLE MANUFACTURER HIGH AS REQ'D, 20 MAX POLE MOUNTING BASE PLATE ASSEMBLY NON-SHRINK GROUT SECTION OF PVC CONDUIT TO BE ADDED TO EXISTING SWEEPING BEND Ø HANDLING SLEEVE (100Ø CORED HOLE) RIGID PVC GROUND WIRE CONDUIT, DIAMETER AS REQUIRED C L Ø HANDLING SLEEVE (100Ø CORED HOLE) AS REQ'D TYP NON-SHRINK GROUT AND MOUNTING ASSEMBLY TO BE INSTALLED BY ON-SITE CONTRACTOR. 1 AS REQ'D FINISH GRADE ANCHOR BOLTS PROVIDED BY POLE MANUFACTURER Ø RIGID PVC POWER CONDUIT AS REQ'D 180 EXTENSION AS REQ'D FILL PIPE WITH CONCRETE Electrical Pole Bases Ø AS REQ'D SECTION A SHAw precast solutions Electrical Pole Bases 9

10 ELECTRICAL POLE BASE THREE CONDUIT TYPE 5 GEOMETRY AND SECTION 1200 Electrical Pole Bases TYP TYPICAL P2 P2 P1 - GEOMETRY P1 4 - ANCHOR BOLTS AS PER SUPPLIERS TEMPLATE, 90º APART A 19Ø PVC CONDUIT FOR GROUND WIRE - REINFORCING B 4-15M BARS E.W E.F. 8-20M L-BARS EMBEDDED IN TO BASE WITH VERTICAL BARS EXPOSED. L-BARS TO BE CAST INTO BASE WITH VERTICAL LEGS EXPOSED. ONCE ANCHOR BOLTS HAVE BEEN SUPPLIED, SECOND POUR OF PEDESTAL WILL BE FORMED AROUND VERTICAL REBAR SECTION OF 19 PVC CONDUIT TO BE ADDED TO 300 EXISTING SWEEPING BEND FINISH GRADE 25 (TYPICAL) 4 - ANCHOR BOLTS AS PER SUPPLIERS TEMPLATE, 90º APART 4-GALZANIZED ANCHOR BOLTS (SUPPLIED BY OWNER) 8-20M L-BARS EMBEDDED IN TO BASE WITH VERTICAL BARS EXPOSED. 4-15M BARS E.W E.F. SECTION A SECTION B REVISED March 14, ø RIGID PVC CONDUIT Ø PVC CONDUIT FOR GROUND WIRE SHAw precast solutions Electrical Pole Bases

11 1610x1700 SINGLE-PHASE PADMOUND TRANSFORMERS kv.a - 167kV.A 4 TON x LIFTING DEVICE TYP. (4 LOCATIONS) B 25 (TYP) A C (BOTH WALLS) SEE DETAIL-A C TYP D 70 TYP C C C1002 C REBAR SCHEDULE C1001-#10M BAR x 1010 LG - 6 REQUIRED C1002-#10M BAR x 1600 LG - 14 REQUIRED C1003-#10M BAR x 10 LG - 20 REQUIRED C1004-#10M BAR x 12 LG - 22 REQUIRED (SEE DETAIL-A) C1005-#10M BAR x 1760 LG - 4 REQUIRED C1006-#10M BAR x 18 LG - 4 REQUIRED DETAIL-A 25 (TYP) 1 SECTION-A C1002 T&B BOTH SIDES 260 (BOTH WALLS) SEE DETAIL-A 260 BOTH WALLS 100 BOTH SIDES SECTION-C C1001 T&B C1003 T&B SECTION-B Ø HOLE FOR GROUND WIRE (BOTH WALLS) (BOTH WALLS) SEE DETAIL-A 260 (BOTH WALLS) 100 (BOTH SIDES) SECTION-D 200 C1003 T&B SHAw precast solutions UTILITY STRUCTURES > 11

12 1610x14 TOP OF FIRE RESISTING BARRIER SINGLE-PHASE PADMOUNT TRANSFORMER kv.a-167kv.a c/c 14 4 SEE DETAIL-A REVISED March 14, MIN. 325 c/c 1 SECTION-A 25 (TYP) 325 c/c SECTION-A 302 c/c 2-GALV. CHECKER PLATES 10x100x100 WELDED TO A STEEL PIPE SLEEVE (TOP & BOTTOM). CHECKER PLATES TO BE DRILLED WITH 22Ø HOLE. TOP PLATE AND CONCRETE TO BE FLUSH. REBAR SCHEDULE C11-#15M BAR x 10 LG - 5 REQUIRED C12-#15M BAR x 13 LG - 6 REQUIRED 25.4Ø (SCHEDULE 40) GALV STEEL PIPE SLEEVE DETAIL-A 19.1Ø COARSE-THREAD NUT TO BE WELDED TO BOTTOM PLATE 12 SHAw precast solutions UTILITY STRUCTURES >

13 2400x2200 THREE-PHASE PADMOUNT TRANSFORMERS 1kV.A - 0kV.A A GEOMETRY C1002 T&B B 10 3-C c/c REINFORCING C c/c 6-C c/c REBAR SCHEDULE C #10M BAR X 2100 LG - 12 REQUIRED C #10M BAR X 2300 LG - 16 REQUIRED C #10M BAR X 14 LG - 4 REQUIRED 25 TYP. 300 C1002 T&B 25 TYP. SECTION GEOMETRY A SECTION REINFORCING B SHAw precast solutions UTILITY STRUCTURES > 13

14 2400x1820 TOP OF FIRE RESISTING BARRIER THREE-PHASE PAD MOUNT (TYP) SEE DETAIL-A 600 MIN c/c c/c REVISED March 14, (TYP) 300 c/c SECTION-A SECTION-A 300 c/c DETAIL-A 2-GALV. CHECKER PLATES 10x100x100 WELDED TO A STEEL PIPE SLEEVE (TOP & BOTTOM). CHECKER PLATES TO BE DRILLED WITH 22Ø HOLE. TOP PLATE AND CONCRETE TO BE FLUSH. 25.4Ø (SCHEDULE 40) GALV STEEL PIPE SLEEVE 19.1Ø COARSE-THREAD NUT TO BE WELDED TO BOTTOM PLATE REBAR SCHEDULE C11-#15M BAR x 2300 LG - 6 REQUIRED C12-#15M BAR x 1600 LG - 8 REQUIRED 14 SHAw precast solutions UTILITY STRUCTURES >

15 3000x3000 THREE-PHASE PADMOUNT TRANSFORMER 0kV.A-20kV.A 25 (TYP) C1007 T&B C1005 T&B 2-C1005 T&B 70 4-C c/c 14 4-C c/c C c/c (TYP) C1007 T&B C1005 T&B C1005 T&B 25 (TYP) SECTION-A SECTION-A REBAR SCHEDULE C1005-#10M BAR x 2900 LG - 38 REQUIRED C1007-#10M BAR x 2190 LG - 8 REQUIRED SHAw precast solutions UTILITY STRUCTURES > 15

16 THREE PHASE PADMOUNT TRANSFORMER 0kV.A - 20kV.A DEEP WELL DESIGN OVERALL GEOMETRY TYP SECTION A TYP. A THREE PHASE PADMOUNT TRANSFORMER 0kV.A - 20kV.A DEEP WELL DESIGN STANDARD REINFORCING C1005 T&B C1007 T&B 2 B 8-C c/c 4-C11 SECTION C 2-C11 2-C1005 T&B 4-C c/c 14 C C c/c D 4-C12 (SEE DETAIL B) SECTION REBAR SCHEDULE C M BAR x 2900 LG - 38 REQ'D C M BAR x 2190 LG - 8 REQ'D C11-15M BAR x 2900 LG - 6 REQ'D C12-15M BAR x 1700 LG - 8 REQ'D C13-15M BAR x 990 LG - 4 REQ'D 4-C13 (SEE DETAIL A) D 4-C12 (SEE DETAIL B) REVISED March 14, 2013 C1005 T&B C1007 T&B C1005 T&B SECTION B 25 TYP º C º 135º 170 C12 6 DETAIL A DETAIL B 135º SHAw precast solutions UTILITY STRUCTURES >

17 3000x2720 TOP OF FIRE RESISTING BARRIER THREE-PHASE PADMOUNT TRANSFORMER 0kV.A-20kV.A GENERAL ARRANGEMENT (TYP) c/c SEE DETAIL-A MIN c/c 1 SECTION-A 25 (TYP) 200 c/c SECTION-A 200 c/c 2-GALV. CHECKER PLATES 10x100x100 WELDED TO A STEEL PIPE SLEEVE (TOP & BOTTOM). CHECKER PLATES TO BE DRILLED WITH 22Ø HOLE. TOP PLATE AND CONCRETE TO BE FLUSH. REBAR SCHEDULE C11-#15M BAR x 2800 LG - 14 REQUIRED C12-#15M BAR x 20 LG - 15 REQUIRED 25.4Ø (SCHEDULE 40) GALV STEEL PIPE SLEEVE DETAIL-A 19.1Ø COARSE-THREAD NUT TO BE WELDED TO BOTTOM PLATE SHAw precast solutions UTILITY STRUCTURES > 17

18 1000 x 1300 UTILITY BOX CS700 DUCT BANK (OPTIONAL) UTILITY STRUCTURES 41'[1040] STANDARD 30" [760] Ø OR AS REQ D 53"[1345] 63"[1600] 51"[1295] VIEW W/OUT COVER VIEW 7" [180] PULLING-IN IRONS (OPTIONAL) AS REQ'D -MAX 66"[16] Specifications: Concrete Minimum Strength: 00psi [35MPa] at 28 days Air Entraining: 5-7% Steel Reinforcement: For HS-25 Construction Joint: Sealed with butyl rope or equivalent Design for HS-25 Load at 2'[600] Bury Notes: Grade Rings Available For Increased Depth of Bury Accessories Holes as Required 6" [1] SECTION THRU CENTERLINE REVISED March 14, SHAw precast solutions UTILITY STRUCTURES

19 AVAILABLE trench SIZES: RISE 2ft 3ft 4ft 5ft 6ft 7ft 8ft 9ft 10ft 11ft 12ft 13ft 14ft 15ft 16ft SPAN 2ft 3ft 4ft 5ft 6ft 7ft 8ft 9ft 10ft 11ft 12ft 13ft 14ft 15ft 16ft HAUNCH WALL THICKNESS SPAN RISE TRENCHES IMPORTANT NOTES: Available Haunch Sizes are: 6 inch (152), 8 inch (203) and 12 inch (305) Span and Rise are available in increments of 4 inches (102) For example, 6 ft 8 inch x 8 ft 4 inch (2032 x 2540) Haunch Size Min. Rise Min. Span 6 inch 2 ft 3 ft 8 inch 3 ft 3 ft 12 inch 4 ft 4 ft Wall thicknesses are available in 2 inch (51) increments For example, 2 inch, 4 inch, 6 inch, etc SHAw precast solutions UTILITY STRUCTURES > TRENCHES 19

Manholes Table of Contents

Manholes Table of Contents Standard MH 300 Title Manholes Requirements MH 300.1 Manholes Requirements Manholes Table of Contents Underground Structures Standards MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Precast Tub-Type

More information

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................

More information

Pipe Product Catalog Table of Contents

Pipe Product Catalog Table of Contents Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"

More information

DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING

DISTRIBUTION VAULT 8' x 14' x 9'-4 DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING CU16003K REV 8' x 14' x 9'4" DEEP TRAFFIC FLAT WALL 0113 SHEET 1 OF 6 CU 16003K CU16003K REV 8' x 14' x 9'4" DEEP TRAFFIC FLAT WALL 0113 SHEET OF 6 CU 16003K ITEM (PER ENDWALL): A. 6" DIAMETER PVC CONDUIT

More information

CONCRETE MANHOLES.

CONCRETE MANHOLES. CONCRETE CONCRETE SHAW PIPE produces circular, precast, concrete manholes in diameters 1050mmØ through 3000mmØ. Precast, concrete manholes are most frequently used for pipeline and sewer entry and are

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting

SECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting SECTION 33 71 19 UNDERGROUND POWER DUCT AND SUB-STRUCTURES PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 33: Trenching, Backfilling, and Compacting B. Section 32 01 00: Site Restoration and Rehabilitation

More information

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

2' x 3' Polymer Pull Box Cover 4'-0 7'-0 24 x 76 Access Opening 3'-6 Scope.1 Precast Concrete Equipment Slab Box 8' x 10' x Pad with 4' x 7' x 3'- Box for 5-Way RAM Gas Switch, 2-Way, 3-Way, and 4-Way Pad-Mounted RAG Gas Switches, VFI 9, VFI 12, Bypass Switch, and 33 kv

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility B 64" 1626 602'-8 1/16" 183695 548'-0" 167030 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 373839 40 25 IMPACT 1500A 48" 12 27'-5" 8355 [] 3x7 CL A Galvanized

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility 19'-11 1/2" 6083 239'-11 1/2" 73139 Impact 1100C 25 43 5/16" 1100 upstream from the upstream face of the first shear fender downstream of the joint between barrier nos. 7 and 8 Upstream End Downstream

More information

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg Contents F-5-1a Concrete Bollards F-5-1b Concrete Bollards F-5-2 Concrete Bollards with City Logo F-5-3 Cast Iron Bollards F-5-4 Decorative Steel Bollard F-5-5 Swivel P Gate Steel Bollard F-5-6 Steel Bollard

More information

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Installation Instructions Bulletin 237029 Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Revision A Introduction This document specifies typical foundation characteristics, designs,

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Installation Instructions Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Bulletin 237186A Revision A Introduction This document specifies typical foundation characteristics, designs,

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence MILWAUKIE OR #3144-00 ADDENDUM #5 NARRATIVE: 11-08-12 WAL-MART SUPERCENTER #3144-00; Milwaukie, OR: SPECIFICATIONS SPECIFICATIONS Revisions to Specification 02822 Fence Spec division 02822 has been revised

More information

STEEL PIPE GUIDERAIL 01/01/

STEEL PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

Customer Connection Guide Updates Effective May 2017

Customer Connection Guide Updates Effective May 2017 This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services

More information

CS3 represents manufacturers of products for use in the municipal waterworks industry.

CS3 represents manufacturers of products for use in the municipal waterworks industry. Brian Drexel & Rob Grier WWW.CS3WATERWORKS.COM Established in 2000, CS3 Waterworks is a Florida Based company with offices in Orange Springs Florida and Savannah Georgia. CS3 represents manufacturers of

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

Thread protection accessories are installed at the MODIX production factory and delivered with couplers.

Thread protection accessories are installed at the MODIX production factory and delivered with couplers. Installation of MODIX Rebar Coupler Identification of the product The type of MODIX Rebar Coupler can be identified by the marking on the product. Size of the Coupler can be identified also according to

More information

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section 02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,

More information

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0", 8'-0", 10'-0" NOMINAL SPREAD

SIG-032-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY III LUMINAIRE ARM (SEE CONTRACT) 6'-0, 8'-0, 10'-0 NOMINAL SPREAD Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"

More information

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8 September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA

MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA MPA Project No. M495-C1 Refrigerated Container Storage Improvements Project Location: Conley Terminal, Boston, MA RESPONSES TO QUESTIONS and/or RFI s Date: 12/7/2017 The attention of Contractors submitting

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

SECTION METAL FABRICATIONS

SECTION METAL FABRICATIONS SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM

More information

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted

More information

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL IRONCLAD SPORTS, INC GAME CHANGER ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL MODEL: GC55-MD (1 piece pole)!! WARNING FAILURE TO COMPLY WITH ANY OF THE WARNINGS IN THESE INSTRUCTIONS

More information

Customer Requirements Commercial Secondary Service

Customer Requirements Commercial Secondary Service Application Installation requirements for commercial services from Tacoma Power overhead or underground facilities. It applies to new construction or upgrades of older services. Electrical service may

More information

Standard Specifications

Standard Specifications Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and

More information

24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

24 B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3  X501 Y301 (Typ.)  A PLAN (reinforced casting option shown) A  dia. Hinge Bar (Typ.) NOT B B Joint Joint See MARKINGS Note PCB-RXX-350-TL3 " Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOTES GENERAL: This barrier may be manufactured with reinforcing steel

More information

STRATUS SHELTER. Take bike parking to new heights

STRATUS SHELTER. Take bike parking to new heights Take bike parking to new heights The Stratus Shelter is a striking bike shelter option for any transit station, university campus, or multi-family residential building project. It is constructed of American

More information

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS 1. DESCRIPTION THESE SPECIFICATIONS ARE FOR A PRECAST THREE SIDED ARCH STRUCTURE, HEADWALLS

More information

Installation Instructions

Installation Instructions Column & Beam Units with Debris Netting Installation Instructions Laminated Wood Systems, Inc. Seward, Nebraska 800-949-3526 2015 LWS, INC. AVR-NET INSTALL 05-12-16 AVR Installation Notes 1 Safety The

More information

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS

Section. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS Section 8 City of Ellensburg ILLUMINATION STANDARDS Table of Contents STREET ILLUMINATION...3-5 GENERAL NOTES...3 INSTALLATION AND CONNECTIONS...3 MARKING...3 STAKING...3-4 TRENCH REQUIREMENTS...4 ILLUMINATION

More information

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL A-1 1 1/2" x 60" Galvanized (thread both ends) Top Bolt See Detail "A-1" and Slotted Channel Parallel Conduit Clamp Warning Sign 3 Equal Bolt Spacings (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x

More information

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) POLE CAP

SIG-030-B TRAFFIC SIGNAL MAST ARM POLE AND MAST ARM DETAILS - CATEGORY I LUMINAIRE ARM 6'-0, 8'-0, 10'-0 NOMINAL SPREAD (SEE CONTRACT) POLE CAP Michigan Department of Transportation 6'-0", 8'-0", 10'-0" NOMINAL SPREAD (SEE CONTRACT) LUMINAIRE ARM (SEE CONTRACT) POLE CAP 1'-6" (6'-0" ARM) 1'-10" (8'-0" ARM) 2'-0" (10'-0" ARM) NOMINAL RISE 2.38"

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard

More information

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome

Mounting Accessories. Installation Guide. VIVOTEK SD83XXE Speed Dome VIVOTEK SD83XXE Speed Dome Mounting Accessories AM-116/117 Pendant Pipe AM-118 Pendant Head AM-221 Gooseneck AM-231 Parapet Mount AM-519 Pendant Adaptor Installation Guide Corresponding part numbers: AM-116:

More information

PART MATERIALS. Section Fencing Materials. Description

PART MATERIALS. Section Fencing Materials. Description PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain

More information

PERFORM WITH PRECISION MAGNETIC PRODUCTS FOR PRECASTING CONCRETE CONSTRUCTION SOLUTIONS BROCHURE

PERFORM WITH PRECISION MAGNETIC PRODUCTS FOR PRECASTING CONCRETE CONSTRUCTION SOLUTIONS BROCHURE MAGNETIC PRODUCTS FOR PRECASTING PERFORM WITH PRECISION CONCRETE CONSTRUCTION SOLUTIONS BROCHURE Form Magnets ON/OFF MAGNETS Strong adhesion and shear capacity -650# to 2500# adhesion Easy to turn on or

More information

Page Electric Utility Service Specifications

Page Electric Utility Service Specifications T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum - UG-1 Sheet 1 of 3 87 T Y P I C A L U N D E R G R O U N D S E R V I C E R E Q U I R E M E N T S 200 Amps Maximum

More information

Standard 25 Wide Structure

Standard 25 Wide Structure Standard 25 Wide Structure Truss Arch Style 2 piece 12ft c/c typical Arch Depth 12 Webbing Diameter 1/2 1 run straight 2 runs straight Wind Brace - up to 120 8 Wind Brace - up to 192 12 Wind Brace - over

More information

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard

More information

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni

Bracket guide. LK Pipe Pole. LK Radiator fixture Uni Bracket guide LK Radiator fixture Uni LK Radiator fixture Uni c/c 40 (Article no. 481 43 92) LK Radiator fixture Uni c/c 50 (Article no. 481 44 03) LK Pipe Pole (Article no. 481 43 91, 481 43 90) Used

More information

Open shipping crate and separate all of the different parts. Over The Top Shelters LLC

Open shipping crate and separate all of the different parts. Over The Top Shelters LLC ASSEMBLY INSTRUCTIONS FOR MODEL SH122110GN and SH122110GY Open shipping crate and separate all of the different parts. Count each part and match up with parts list. Shortages or damaged parts should be

More information

INVITATION FOR BID (IFB) IFB NO. GSWA

INVITATION FOR BID (IFB) IFB NO. GSWA INVITATION FOR BID (IFB) IFB NO. GSWA-005-16 AGAT AND MALOJLOJ RESIDENTIAL TRANSFER STATION IMPROVEME AND DEDEDO RESIDENTIAL TRANSFER STATION CLOSURE ADDENDUM NO. 6 September 22, 2016 ALL BIDDERS MUST

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.

More information

DOCK WEDGE - STANDARD

DOCK WEDGE - STANDARD DOCK WEDGE - STANDARD INSTALLATION INSTRUCTIONS WOOD HEADER READ ALL INSTRUCTIONS BEFORE INSTALLING SEAL. SUPER SEAL MFG. LTD. WILL NOT BE HELD RESPONSIBLE FOR IMPROPER INSTALLATION OF ANCHORING DEVICES,

More information

New Product Release: October 2014 Boone Racks

New Product Release: October 2014 Boone Racks New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance

More information

STRUCTURAL ATTACHMENTS

STRUCTURAL ATTACHMENTS Brace Structural Attachment Selection Procedure ) Determine structure to be attached to from the following: A) Concrete B) Wood Beam C) Structural Steel 2) Reference structure connection type from Appendix

More information

1. In the Y direction: to the vertical axis of the wall (middle of the wall)

1. In the Y direction: to the vertical axis of the wall (middle of the wall) Installation of TENLOC Panel Connectors Precast Factory Installation of the TENLOC The is placed into the reinforcement of the wall and attached to the mold with nails. The wall thickness must be minimum

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility C 1690" A 42926 75" 1905 150" 3810 G E F F 11 10 9 8 7 6 5 4 3 2 C D D 25 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 21.2 G E Impact 2270P 17 Spaces @ 75" [1905] Spacing = 106' 3" [32385] 1 1662 1/2"

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (15-03) MANUAL: Standard

More information

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-01) MANUAL: Standard

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS

10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS 10x12 FOUNDATION GUIDE 10x12 TRICO AND FLORA SHEDS 10x12 WOOD SKID FLOOR FLOOR SYSTEM FOR 10x12 TRICO AND FLORA SHEDS RAW MATERIALS LIST: 2 (9) FLOOR FRAMING AND SHEATHING: 1) BAND BOARD 2 x 6 x 12 PRESSURE

More information

H O O P RAC K. Simple Security

H O O P RAC K. Simple Security H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop

More information

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts Capped Cellular PVC Fencing Installation Guide Table of Contents Storage and Handling Tools Needed Fence Layout and Locating Posts Installation instructions 4 x 4 Over Sleeve Post - 3.5 Rail Privacy Shadowbox

More information

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off

Lid, Floor Monument and Two Installation Fixtures. Floor Monument Installed with Lid On and Off Monumentation Drilling Specifications: Floor Monuments: - Floor is drilled using 1 3/4" core drill bit to a depth of 2 with a Hilti rotary hammer drill - Quikrete is used to set monuments into the floor

More information

B " 787

B  787 175'0" 53339 3H:1V S.B.P. 25" 635 3H:1V Slope 100'0" 30480 Soil Cut 3H:1V Slope 58" 1474 75" 05 1 2 3 4 5 6 7 8 9 10 11 12 13 25 14 15 16 17 18 20 21 22 23 24 25 2270P Impact 243 60 12 Spaces @ 75" [05]

More information

Today s Service Station

Today s Service Station F I X IT Today s Service Station The Fixit includes all the tools necessary to perform basic bike repairs and maintenance, from changing a flat to adjusting brakes and derailleurs. The tools and air pump

More information

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete

More information

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop

MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop 500 460 MDOTProjectwise\Documents\Reference Documents\Traffic Reference\Statewide Special Details\Develop Check if Applicable TRAFFIC SIGNAL SPECIAL DETAILS INDEX/CHECKLIST *One completed checklist required

More information

Directions for the 25' Jr Batting Cage & Frame

Directions for the 25' Jr Batting Cage & Frame Directions for the 25' Jr Batting Cage & Frame Parts Qty Part Description 1 6 Upper corners of the arch (with hex bolts) 2 6 Bent pipe for arch feet 3 6 Pipe with no swedge (2 per horizontal arch) 4 12

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

INSTALLATION INTRUCTIONS

INSTALLATION INTRUCTIONS INSTALLATION INTRUCTIONS Page 1 of 9 Installation Instructions 1. 2. Check all items against parts list to ensure all parts have been included (see pages 6,7,8,9). Locate and drill holes for concrete footings.

More information

MAST ARMS & POLES. Ornamental Pole Top & Bases

MAST ARMS & POLES. Ornamental Pole Top & Bases Ornamental Pole Top & Bases Pelco s decorative pole top and bases make the traffic signal aesthetically pleasing to the eye. In addition to the standar 4-piece, Pelco also manufactures the bases with an

More information

OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO

OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO OHIO DEPARTMENT OF TRANSPORTATION CENTRAL OFFICE, 1980 W. BROAD ST., COLUMBUS, OHIO 43216-0899 July 20, 2012 To: Users of the Standard Bridge Drawings From: Tim Keller, Administrator, Office of Structural

More information

Swerve Rack CUSTOM RACKS AVAILABLE

Swerve Rack CUSTOM RACKS AVAILABLE CUSTOM RACKS AVAILABLE Swerve Rack The design of the Swerve mirrors the bike frame, thus providing superior bike support while making it easy to secure both the bike frame and wheel with a standard u-lock.

More information

INSTALLATION GUIDE PermaTrak. Patented Product: U.S. Patent #5,906,084 #8,302,362 #8,522,505 #8,839,588 #9,096,975

INSTALLATION GUIDE PermaTrak. Patented Product: U.S. Patent #5,906,084 #8,302,362 #8,522,505 #8,839,588 #9,096,975 INSTALLATION GUIDE 2009-2017 PermaTrak. Patented Product: U.S. Patent #5,906,084 #8,302,362 #8,522,505 #8,839,588 #9,096,975 Table of Contents Project Overview Forward, Acceptability Criteria, Safety,

More information

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL IRONCLAD SPORTS, INC HIGHLIGHT HOOPS ADJUSTALE ASKETALL SYSTEM ASSEMLY INSTRUCTIONS AND OWNER'S MANUAL MODEL: HIL885!! WARNING FAILURE TO COMPLY WITH ANY OF THE WARNINGS IN THESE INSTRUCTIONS MAY RESULT

More information

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846 PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y Proposal P.O. Box 846 Baker, MT 59313 P R E C A S T R E I N F O R C E D C O N C R E T E B O X C U L V E R T F O R W E S T M O

More information

PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE

PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE PSI COMPAKT SEALS AND WALL SLEEVES WITH FIXED/LOOSE FLANGE IN GALVANIZED OR STAINLESS STEEL FOR BUILDINGS WITH OR WITHOUT SEALING SHEETS IN SPLIT VERSION FOR RETROFITTING WWW.PSI-PRODUCTS.COM 37 GENERAL

More information

SADDLE BUDDY EASY ASSEMBLY. The Saddle Buddy is easy to install Galvanized Surface In-Ground. Rail.

SADDLE BUDDY EASY ASSEMBLY. The Saddle Buddy is easy to install Galvanized Surface In-Ground. Rail. SAD D L E B U D DY Saddle Up. Designed for trailheads, bike parks and picnic areas, the Saddle Buddy offers a resting place for cyclists noble steeds. The convenient bar allows cyclists to keep their bikes

More information

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear Cast-in Ferrule Connections Load/Displacement Characteristics in Shear Ian Ferrier 1 and Andrew Barraclough 2 1 Product Manager - Connections, ITW Construction Systems ANZ. 2 Research and Development Manager,

More information

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

STORM M ANHOLE FOR 42 PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30MAX 3 OR 3.5 PRECAST ECCENTIC CONC 01-APR-2015 13:33 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\stm_det01_8x11_st01.dgn TIME = MIN 3 CRSES MAX 5 CRSES 3 OR 3.5 PRECAST ECCENTIC CONC ID PIPE GRADE A CONC FILL 4" 8" 2-0"SUMP

More information

H O O P RAC K. Simple Security

H O O P RAC K. Simple Security H O O P RAC K Simple Security The Hoop Rack is a proven design that provides high security and easy bike parking. The Hoop Rack uses thick pipe construction and the full radius of the bend makes the Hoop

More information

Plastibeton Trench System. Installation Packet

Plastibeton Trench System. Installation Packet Plastibeton Trench System Installation Packet Plastibeton Installation Guide This Installation Guide is intended to assist in the preparation and installation of Plastibeton products manufactured by Oldcastle

More information

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D ASPHALT 20 GUTTER LINE CONCRETE CURB FINISHED GRADE PRECAST GRADE RINGS, 2 50 100 MAX PRECAST CB LID GROUT ALL AROUND CB LEAD, INSIDE & OUTSIDE OF

More information

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections

SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS. Notification of Completed Conduit Sections SPECIFICATIONS FOR THE INSTALLATION OF CONDUIT SYSTEMS IN RESIDENTIAL SUBDIVISIONS Section 1 Definitions 2 Scope of Work 3 Extent of Work 4 Inspection and Performance of Work 5 Trenching 6 Duct Installation

More information

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER WOOD SERVICE MARKER STAKE (50 x 00) PAINTED BLUE PL mm FROM PROPERTY LINE STANDARD CONCRETE SERVICE BOX WITH EXTENSION AS REQ'D 00 FINISHED GROUND/ROAD SURFACE FOR SERVICE BOXES IN CONCRETE DRIVEWAYS,

More information

S W E RV E RAC K. Simple Security. Simple Stability.

S W E RV E RAC K. Simple Security. Simple Stability. S W E RV E RAC K Simple Security. Simple Stability. The Swerve Rack is a proven design that provides high security and easy bike parking. The Swerve Rack uses thick pipe construction and the full radius

More information

Delivering Reliability. Services. Strength You Can Count On. oldcastleprecast.com/services

Delivering Reliability. Services. Strength You Can Count On. oldcastleprecast.com/services Delivering Reliability A Strength You Can Count On SERVICES TENANT IMPROVEMENTS Above And Below Ground Solutions Strength You Can Count On Oldcastle Precast is well trained and knowledgeable in all aspects

More information

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL

ADJUSTABLE BASKETBALL SYSTEM ASSEMBLY INSTRUCTIONS AND OWNER'S MANUAL DJUSTBL BSKTBLL SYSTM SSMBLY INSTRUCTIONS ND OWNR'S MNUL!! WRNING FILUR TO COMPLY WITH NY OF TH WRNINGS IN THS INSTRUCTIONS MY RSULT IN SRIOUS PRSONL INJURY. FILUR TO COMPLY MY LSO RSULT IN PROPRTY DMG.

More information

INDEX PAGE RELEASE SECTION NUMBER DATE

INDEX PAGE RELEASE SECTION NUMBER DATE INSTALLATION INSTRUCTIONS For Wind Zone 1 (other Wind Zones available on request) Version 11/20/2002 INDEX PAGE RELEASE SECTION NUMBER DATE Approval INTRODUCTION 2 2/26/2001 GENERAL INSTALLATION 3 2/26/2001

More information

UNDERGROUND UTILITY VAULTS

UNDERGROUND UTILITY VAULTS LEED Reference Guide For Precast Concrete Products Perfect for communications, electrical, gas or steam systems, precast concrete utility structures protect the vital connections and controls for utility

More information

Figure 11 Flange Adapter and Back-Up Ring

Figure 11 Flange Adapter and Back-Up Ring Flange Adapters Standard back-up rings are Standard back-up rings are convoluted ductile iron with AWWA C207 150 lb drilling. One edge of the back-up ring bore must be radiused or chamfered. This edge

More information

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES

HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES HOME STRENGTHENING GUIDE HOW TO ECONOMICALLY STRENGTHEN YOUR HOUSE AGAINST EARTHQUAKES AND HURRICANES Grenville W Phillips II BSc, BEng, MASc, MURP, CEng, FIStructE, FCIHT, MAPM, MCSCE, MBAPE Chartered

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

Moment Resisting Connections for Load Bearing Walls

Moment Resisting Connections for Load Bearing Walls PRECAST: MOMENT RESISTING CONNECTIONS Moment Resisting Connections for Load Bearing Walls Manish Khandelwal Sr. Structural Engineer, Building Structures, Sweco India Private Limited Design philosophy for

More information

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September

More information

AUXILIARY FRAMING AND ACCESSORIES

AUXILIARY FRAMING AND ACCESSORIES CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION

More information

HOENER ASSOCIATES INC. ARCHITECTS

HOENER ASSOCIATES INC. ARCHITECTS HOENER ASSOCIATES INC. ARCHITECTS BRUCE D. DELL MARK REUTHER ADDENDUM NO. 1 PROJECT 15-22C RENOVATION AND SITE WORK AT: BUILDING B DDRB OF ST. CHARLES DEVELOPMENT DISABILITIES RESOURCE BOARD ST. CHARLES,

More information