MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

Size: px
Start display at page:

Download "MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C"

Transcription

1 MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs.

2 General The Armtec Sluice Gate is a quality and highly economical gate for a variety of low head applications including: Irrigation turnout structures Water and wastewater treatment plants Flood control and retention ponds Storm and sanitary sewers (Deluxe Model) Pump Stations Design The 20-10C Sluice Gate is available in standard sizes from 203 mm to 1067 mm diameter and designed to withstand: 20 (6m) of face pressure (seating head) 10 (3m) of back pressure (unseating head) The gate consists of a flat back cast iron seat, slide and cross-bar, which is attached to a galvanized steel frame and yoke. The yoke supports the lift system forming a self-contained unit. Its flat back configuration makes it suitable for mounting to pipes, thimbles and concrete headwalls and manholes. Sluice Gate Standard Model Materials Frame Galvanized Steel Stem Carbon Steel Gate Seat and Slide Cast Iron with Polyamine Epoxy Coating Seating Faces Machined Cast Iron Fasteners Zinc Plated Steel Note: Suitable for most storm sewer and irrigation water applications. Deluxe Model Materials Frame Stainless Steel Stem Stainless Steel Gate Seat and Slide Cast Iron with Self-priming Epoxy Coating Seating Faces Machined Bronze Fasteners Stainless Steel Note: Suitable for most sanitary sewer applications. Revised October

3 Gate Seats/Seals The slide moves vertically along machined cast iron faces (Standard Model) or machined bronze faces (Deluxe Model) which are attached to the frame and slide. Sealing is achieved by two adjustable side wedges that come in contact with faces on the slide cross bar just as the gate approaches the closed position. The sealing faces do not protrude into the waterway opening, allowing for full sluice discharge. Typical Slide/Seat Cross Section # Part Description 1 Slide 2 Cross Bar 3 Side Wedge 4 Yoke Side Supports Frame 5 Gate Seat Revised October

4 Mountings The 20-10C Gate can be installed onto a variety of mounting surfaces as defined by the following codes: On Concrete Surface FC (Flat Concrete Wall) CC( Curved Concrete Wall) On Steel Surface MF (Metal Flange) MT (Metal Thimble) Flat Concrete Wall Mounting (FC) Side Cross Section Curved Concrete Wall Mounting (CC) Side Section Metal Flange Mounting (MF) Side Cross Section Revised October 2007 Metal Thimble Mounting (MT) Side Cross Section 3

5 Standard Configurations and Sizes The Engineering Table below summarizes the available gate diameters and dimensional data for each size of gate. These gates are stocked in standard frame heights as listed, but custom fabricated configuration options are available. Various lift extensions are available, as shown on Page 5. Contact an Armtec Sales Representative for more information. Anchor Bolt C H Frame Height D E ARMTEC B Gate Opening Diameter Anchor bolt F A A+204 mm Installation Clearance 102 Dimension Data Stock Anchor Bolt Gate Stem Lift Frame Bolt Circle Diameter A B C D E F Diameter Type Height Diameter Diameter mm mm mm mm mm mm mm mm mm mm mm mm LW LW LW LW LW LW LW LW LW LW Revised October

6 Lift Extensions Detailed Configuration Options and Material Specifications Manual type lift with handwheel Pedestal T-wrench handle Floor box with cover Stem Stem clamp with bushing Lift operator extension (LOE) LOE Clamp Lift Stem ARMTEC ARMTEC Pedestal to Slab (FP) T-Wrench with Lift Operating Extension (TWH) Manual type lift with hand wheel Manual type lift with hand wheel Wall bracket Stem guide Stem Pipe frame extension Pipe frame clamp Stem ARMTEC ARMTEC Pedestal to Wall Bracket (FPW) Pipe Frame Extension (PFE) Revised October

7 Stem Covers Stem covers should always be used for outside installations to keep the stem threading clean of fine grit which can increase lift nut wear and the amount of torque to operate gate. The stem cover is made of aluminum with lexan plastic viewing windows. Markings are provided in metric and imperial units to mark the location of the gate position. Stem Guides Stem guides are provided as required to support the stem from buckling. The stem guides are designed as per AWWA Standards. The stem guide is fabricated from 304 stainless steel with an ultra high molecular weight polyethylene (UHMWPE) bushing. Aluminum stem cover with LEXAN window ruler with metric and imperial units. Fabricated stainless steel stem guide clamp with UHMWPE bushing. Electric Lift Option Manual gates can be provided with Armtec s electric Drill Pak System. The Drill Pak System comes complete with Industrial Duty electric drill (110V, Single Phase, 60 Hz), mounting tripod, clutch and 2 square adapter socket. The Drill Pak is designed to be operated in the horizontal position. gates can also be provided with an electric actuator in place of manual lift systems. Contact an Armtec Sales Representative for more information. Revised October

8 Gate Identification Code: (The Gate Identification Code is a fast and efficient method to specify the gate which is required.) 1. Gate Series 20-10C 2. Opening size in millimeters diameter 3. Gate Material Standard or Deluxe Code Material S D Cast iron gate, Cast iron seating faces, galvanized frame, zinc-plated fasteners, carbon steel stem Cast iron gate, Bronze seating faces, 304 stainless steel frame and fasteners, 303 stainless steel stem 4. Mounting Type Code Mounting Surface On Concrete Surface FC Flat Concrete Wall CC Curved Concrete Wall (Aperature opening only) On Metal Surface MF Metal Flange (Aperature opening only) MT Metal Thimble (Aperature opening only)) 5. Lift Configuration Code Lift Type SCF Hand Mounted on Yoke FP Pedestal to Slab TWH T-Wrench Handle Lift Operator Extension PFE Pipe Frame Extension FPW Pedestal to Wall Bracket Series Size Gate Mounting Lift (mm) Material Type Configuration 20-10C Revised October

9 Common Gate Identification Codes: Examples 1 and 2 show common frame and stem configurations and resulting gate codes: Example 1 Gate Series (20-10C) Size (305 mm diameter) Standard Gate Mounting Surface Flat Concrete Wall (FC) Handwheel on Yoke (SCF) Example 2 Gate Series (20-10C) Size (914 mm diameter) Deluxe Gate Mounting Surface Metal Flange (MF) Pipe Frame Extension Series Size Gate Mounting Lift (mm) Material Type Configuration 20-10C 305 S FC SCF Series Size Gate Mounting Frame (mm) Material Type Configuration 20-10C 914 D MF PFE 20-10C 305-S-FC-SCF 20-10C 914-D-MF-PFE 305 ARMTEC ARMTEC 914 Revised October

10 Gate Specifications 1. General Specifications 1.1 Scope This specification covers medium duty cast iron sluice gates and operators in which the gate is designed to withstand seating or unseating heads in water supply applications. 1.2 Governing Standards No AWWA specifications currently cover the use of medium duty cast iron sluice gates. 1.3 General The gate assembly shall consist of the gate frame and slide, stem, lift mechanism and accessories. The gate assembly shall be designed, fabricated and shop assembled in accordance with the manufacturer s shop drawings and specifications. 1.4 Acceptance of Approved Alternate Products To be considered by the Engineer as an approved alternate product, the alternate gate manufacturer shall submit a list of 50 fabricated slide gate projects (minimum) indicating proven operation in similar applications. 1.5 Quality Assurance Prior to shipment, the gate assembly shall be shop inspected and adjusted for proper operation. 1.6 Submittals The manufacturer s shop drawings shall indicate the gate assembly s opening size, type of material, schedule of parts and principal dimensions. Gate assembly installation procedures shall also be provided to supplement the shop drawings. 2. Performance Seating and unseating heads shall be measured from the water surface to the centre of the gate slide. The gate assembly shall be designed to the design heads shown below: Seating Head: 6.1m (20 ) Unseating Head: 3.05m (10 ) 3. Gate Assembly Product Details The gate assembly shall consist of the gate seat, frame, slide, crossbar, wedges, stem, lift mechanism and accessories. The gate assembly shall be factory assembled prior to shipment. The gate assembly shall be available in standard and deluxe material combinations as detailed in Section 4 (Materials). 3.1 Gate Seat and Frame The cast iron gate seat shall have a flat back configuration suitable for attachment to a concrete wall or a round pipe flange. The self-contained gate frame shall consist of two vertical side guide angles and horizontal head angle, attached to the cast iron gate seat. 3.2 Gate Slide, Crossbar and Wedges The cast iron gate slide shall incorporate integral guides to engage the side angles and permit travel of the slide. A horizontal cast iron crossbar, bolted to the gate slide, shall incorporate side wedges that engage wedges mounted to the side angles. 3.3 Gate Seating Faces The gate shall be furnished with machined metal seating faces available in standard and deluxe material combinations detailed in Section 4 (Materials). In the closed position, the clearance between the seat and the slide shall not exceed (0.10 mm). 3.4 Gate Assembly Fasteners Gate Assembly Fasteners shall be in accordance with Section 4 (Materials). 3.5 Mounting Gaskets and Anchors The gate shall be mechanically fastened to the mounting surface with anchor bolts or with fasteners. Gasket material shall be buytl rubber sealant in accordance with Section 4 (Materials). 3.6 Stem The gate slide shall be raised by a rising stem lift system. The stem shall be available in the material combinations as detailed in Section 4 (Materials) with stem threads machine cut of the acme type. The bottom of the stem shall be hooked to engage a pocket on the front face of the gate slide. Revised October

11 The minimum stem diameters are detailed below: Gate Size Range Stem (mm) Diameter (mm) Stem Covers The stem cover shall be made of aluminum with LEXAN window. Markings shall be provided in metric and imperial units to mark the location of the gate position. 4.0 Materials 3.8 Lifting System The lift system shall consist of a handwheel, or hard crank lift nut, stop nut and housing designed such that the gate can be operated with a maximum of 110N pull. The lift nut shall be cast such that a 51 mm square nut protrudes from the top so that the hand wheel, lift operating extension or T-wrench can be attached. The stop nut shall be furnished to limit the downward travel of the stem when the closed position is reached. The lift system shall be supplied as per the Slide Gate Schedule (Section 5). Component Standard Model 20-10C Deluxe Model 20-10C Seat Cast Iron A48 Cast Iron A48 Class 30 Class 30 Frame Galvanized Steel SSTL (Type 304 or 304L) Structural steel ASTM A276 CSA G164 Slide, Crossbar and Wedges Cast Iron A48 Cast Iron A48 Class 30 Class 30 Seating Faces Cast Iron Aluminum Bronze A48, Class 30 ASTM B36, C26000 Assembly Fasteners Zinc Plated Steel SSTL (Type 304) Grade 5 (Bolts) ASTM F593 (Bolts) Grade 2 (Nuts) ASTM F594 (Nuts) Mounting Gasket Butyl Joint Sealer (12 mm square) Butyl Joint Sealer (12 mm square) Hamilton Kent Kent Seal Hamilton Kent Kent Seal Anchor Bolts Zinc Plated Steel SSTL (Type 304) Grade 5 (Bolts) ASTM F593, F594 Grade 2 (Nuts) Stem Carbon Steel SSTL (Type 303) C1018/1020 ASTM A582 Stem Cover Aluminum Aluminum Lift Housing Cast Iron Cast Iron A48, Class 30 A48, Class 30 Lift Nut Cast Zinc Aluminum Cast Zinc Aluminum ZA12 ZA12 Handwheel Cast Aluminum Cast Aluminum AA No AA No Paint Amerlok 400 Amerlok 400 (Wedges, Slide, Seat and Crossbar) 10

12 5. Slide Gate Schedule Gate Tag No. Gate Type Dimensions (diameter) Head (Seating/Unseating) (20 seating Head Max/10 unseating Head Max) Mounting Surface (FC, CC, MF, MT) Invert Elevation Operating Floor Elevation Lift Type 6. Installation Handling and installation of all components shall be in accordance with the manufacturer s shop drawings and installation instructions. If the gate is to be mounted to a concrete wall, extra care should be taken to ensure that the wall is flat and smooth with a maximum variation of 3mm across the mounting surface of the gate. 7. Commissioning After installation of the gate, the seating surfaces shall be cleaned thoroughly of all foreign materials, the stem lubricated (if required) and the final adjustments made. The gate shall then be cycled from the fully closed to the fully open position to ensure smooth operation of the gate. If an electric actuator is installed, the limit switches shall be set in accordance with the manufacturer s installation instructions. Revised October

13 Armtec 20-10C Quick Inquiry Sheet Project Name: Company Name: Address: Phone: Fax: Unit of measure: mm inch Step 1: Tag Number : Quantity of Gates : Material: Standard (Galvanized Frame, Zinc Plated Fasteners, Cast Iron Seating Faces) Deluxe (304SS Frame, 304SS Fasteners, Bronze Seating Faces) Step 2: Gate Size : Diameter Diameter: Revised October

14 Step 3 Operating Requirements Seating head: Unseating head: Invert Elevation: Operating Floor Elevation: DISTANCE FROM INVERT TO OPERATING FLOOR SEATING HEAD UNSEATING HEAD Gate cl INVERT ELEVATION Step 4 Mounting Requirements Concrete Wall (FC) Metal Flange (MF) Curved Back (CC) Cast Iron Thimble (MT) Thimble Depth Thimble Type ( F or E ) Diameter Step 5 Lift Requirements Manual LW Manual Bearing: Manual Geared: Electric: Volts Phase Cycle Special Requirements Cylinder : Water: Air: Operating Pressure: Step 6 Lift Mounting Self Contained Frame (SCF) T-Wrench with Lift Operating Extension (LOE) Pipe Frame Extension (PFE) Pedestal to Slab (FP) Pedestal to Wall Bracket (FPW) Revised October

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

SPECIFICATION: ALUMINUM SLIDE GATES

SPECIFICATION: ALUMINUM SLIDE GATES SPECIFICATION: ALUMINUM SLIDE GATES PART 1 GENERAL 1.1 The Slide gates shall be manufactured from Aluminum material as specified and shall be Flange back type suitable for wall thimble mounting and generally

More information

Rodney Hunt. A GA Industries Company Glydaseal Gates

Rodney Hunt. A GA Industries Company Glydaseal Gates Rodney Hunt A GA Industries Company Glydaseal Gates GUIDE BRONZE GUIDE BAR FRAME NUT POCKET SEAT FACING RESILIENT INVERT SEAT DISC GUIDE BAR ADJUSTMENT BOLT WITH LOCK NUT GUIDE BAR ATTACHING BOLT The Glydaseal

More information

Section Heavy Duty Slide Gates Tender No. [ ] Page 1

Section Heavy Duty Slide Gates Tender No. [ ] Page 1 Tender No. [ ] Page 1 1.0 GENERAL 1.1 REFERENCES.1 Provide heavy duty slide gates in accordance with the following standards (latest revision) except where specified otherwise..2 American Society for Testing

More information

PENSTOCK VALVES. Performance through Excellence

PENSTOCK VALVES. Performance through Excellence VALVES & MANUFACTURING (1988) LTD. PENSTOCK VALVES Performance through Excellence SLIDEGATES WEIR GATES STOP LOGS SLIDEGATES PRECISION FACE SEALING VALVES WEIR GATES STOP LOGS SLIDEGATES Actuation Installation

More information

SLIDE GATE. The MU series is used mainly in water treatment, irrigation, hydraulic works and hydro-electric power plants.

SLIDE GATE. The MU series is used mainly in water treatment, irrigation, hydraulic works and hydro-electric power plants. SLIDE GATE The model is a rectangular penstock suitable for wall and thimble mounting, with a resilient sealing member applied to all 4 sides. There are two different designs, which are size dependent,

More information

SLIDE GATE SERVICE CONDITIONS

SLIDE GATE SERVICE CONDITIONS SLIDE GATE The model is a 4 side sealing slide gate designed for wall mounting. It is used mainly in water treatment, irrigation, hydraulic works and hydroelectric power plants. There are two different

More information

Cast Iron Slide Gates

Cast Iron Slide Gates Cast Iron Slide Gates Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent

More information

CONSTRUCTION MATERIALS SERVICE CONDITIONS. Alternative alloy materials, like AISI 904L or DUPLEX stainless steel, are available if required.

CONSTRUCTION MATERIALS SERVICE CONDITIONS. Alternative alloy materials, like AISI 904L or DUPLEX stainless steel, are available if required. SLIDE GATE The model is a rectangular penstock suitable for wall and thimble mounting, with a resilient sealing member applied to all 4 sides. There are two different designs, which are size dependent,

More information

INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens

INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens INSTALLATION MANUAL Sluice Gates, Stop-logs & Screens INTRODUCTION During manufacture and assembly of equipment great care is taken to ensure accuracy in mating the sealing faces on frame and doors, especially

More information

Pioneers in Gate Design

Pioneers in Gate Design Stop Logs Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent Hydro Gate

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard

More information

Stop Gates & Stop Logs. Series 500. ine. Manufacturing high quality gates since 1977

Stop Gates & Stop Logs. Series 500. ine. Manufacturing high quality gates since 1977 Stop Gates & Stop Logs Series 500 Manufacturing high quality gates since 1977 ine Stop Gates & Stop Logs Series 500 Contents Stop Gate Introduction 3 Model 501 3 Model 503 4 Model 503-C 4 Stop Gate Specification

More information

CONSTRUCTION MATERIALS

CONSTRUCTION MATERIALS CHANNEL GATE The model is a rectangular penstock designed for open channel installation. A resilient sealing feature is incorporated on 3 sides, (both laterals and bottom), resulting in a perfect seal

More information

RELINER INSIDE DROP SYSTEM SPECIFICATIONS

RELINER INSIDE DROP SYSTEM SPECIFICATIONS 1. PRODUCT NAME RELINER INSIDE DROP SYSTEM U.S. Patent 6074130 Canadian Patent # 2269565 All RELINER Products are proudly made in the U.S.A. 2. MANUFACTURER RELINER /Duran Inc. 53 Mount Archer Rd. Lyme

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

Stainless Steel Gates Series 900 AWWA C561 Compliant

Stainless Steel Gates Series 900 AWWA C561 Compliant Stainless Steel Gates Series 900 WW C561 Compliant Introduction...2 dvantages...2 3 Design Features...3 Optional Features...4 Gate Selection Criteria...4 5 pplication Chart...6 Sluice Gate Mounting...7

More information

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section 02760-1 of 5 SECTION 02760 STEEL LIGHTING STANDARDS 02760.01 GENERAL A. Description Steel lighting standards shall include, but not necessarily be limited to, furnishing and installing steel lighting poles,

More information

HEAVY DUTY HG560 CAST IRON SLIDE GATE

HEAVY DUTY HG560 CAST IRON SLIDE GATE HEAVY DUTY HG560 CAST IRON SLIDE GATE Heavy Duty HG560 Cast Iron Slide Gates Table of Contents Heavy Duty HG560 Cast Iron Slide Gates: Applications...1 Description...1-3 Gate Frame Design...3-4 Gate Slide

More information

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface.

This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. SPEC-3500 1/9 1.0 PURPOSE This specification describes the minimum requirements for service water piping systems (ie: cooling water, process water, etc.), located on surface. Note: This specification does

More information

SECTION METAL FABRICATIONS

SECTION METAL FABRICATIONS SECTION 05100 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes specifications for metal fabrications, including minimum requirements for fabricator, and galvanizing. 1.02 REFERENCE STANDARDS A. ASTM

More information

PENSTOCKS Sluice Gates

PENSTOCKS Sluice Gates Sluice Gates PENSTOCKS ENGINEERED FOR WATER SİSMAT ULUSLARARASI is a well-known penstock supplier, manufacturing high quality, high performance water control gates for all industries as standard designs

More information

PART MATERIALS. Section Fencing Materials. Description

PART MATERIALS. Section Fencing Materials. Description PART 03000 - MATERIALS Section 03010 - Fencing Materials Description 03010.00 Scope - This section consists of the test requirements, specifications and tolerances for barbed wire, woven wire and chain

More information

SECTION COMMON WORK RESULTS FOR HVAC

SECTION COMMON WORK RESULTS FOR HVAC SECTION 23 05 00 COMMON WORK RESULTS FOR HVAC PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Ball Valve. 2. Hangers and Supports. 3. Identification Tags and Sleeves. 1.2 INCLUDED SECTIONS A. Section

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3004 1/7 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Water Design Conditions Operating Conditions 10 PSIG @ 33 o F to

More information

AVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS

AVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS AVK PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS AVK PENSTOCK RANGE AVK UK is part of the globally renowned AVK group who are based in over 85 countries and are known as one of the leading innovators and manufacturers

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2

SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2 SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT Addendum No. 2 The following shall modify the Contract Documents. The work shall be accomplished in accordance with such modifications.

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/01/13 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Service Air Design Conditions Operating Conditions Blast Air (see Note 1)

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: 201/11/2 1/9 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Underground Service Water Note: This specification does not apply to piping

More information

Installation, Operation and Maintenance Manual. RB Weir Gate

Installation, Operation and Maintenance Manual. RB Weir Gate Installation, Operation and Maintenance Manual RB Weir Gate INDEX Introduction. Handling and Storage Installation... Weir Gate installation. Concrete Wall Mounted..... Concrete Round Manhole Wall Mounted.

More information

INVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS

INVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS INVICTA PENSTOCK SOLUTIONS PENSTOCK SOLUTIONS INVICTA PENSTOCK RANGE Invicta is a well established, service driven company offering complete valve, penstock and actuator solutions. Invicta Valves was formed

More information

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM). PART 1 - GENERAL 1.1 SECTION INCLUDES A. Benches. B. Trash receptacles. C. Bike storage. 1.2 REFERENCE STANDARDS A. Including but not limited to: 1. American Society for Testing and Materials (ASTM). 1.3

More information

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP 1 1 1 0 1 0 1 0 1 SECTION 1 1 CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP BASED ON DFD MASTER SPECIFICATION DATED /01/ P A R T 1 - G E N E R A L SCOPE The work under this section shall consist of

More information

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS A. Drawings and General Provisions of Contract, including General and Supplementary Conditions and

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections.

.1 Materials and installation for steel piping, valves and fittings for hydronic systems in building services piping..2 Related Sections. Issued 2006/08/01 Section 15183 Hydronic Systems: Steel Page 1 of 6 PART 1 GENERAL 1.1 SUMMARY.1 Section Includes..1 Materials and installation for steel piping, valves and fittings for hydronic systems

More information

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION 05720 METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL EMMEGI ARCHITECTURAL FENCING is a high quality steel fencing system comprised of a hybrid

More information

NAVSEA STANDARD ITEM T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods

NAVSEA STANDARD ITEM T9074-AS-GIB-010/271, Requirements for Nondestructive Testing Methods NAVSEA STANDARD ITEM ITEM NO: 009-48 DATE: 29 JUL 2011 CATEGORY: II 1. SCOPE: 1.1 Title: Pressure Seal Bonnet Valve; repair (shop) 2. REFERENCES: 2.1 S9086-CJ-STM-010/CH-075, Fasteners 2.2. T9074-AS-GIB-010/271,

More information

Fisher 667 Diaphragm Actuators Size 80 and 100

Fisher 667 Diaphragm Actuators Size 80 and 100 Instruction Manual 667 Size 80 and 100 Actuators Fisher 667 Diaphragm Actuators Size 80 and 100 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Maximum Pressure Limitations...

More information

TO O L K IT. Public Bike Repair

TO O L K IT. Public Bike Repair TO O L K IT Public Bike Repair The Dero Tool Kit includes all the necessary tools to perform most routine maintenance and adjustments on most bikes. All the tools are securely fastened with stainless steel

More information

Standard Specifications

Standard Specifications Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and

More information

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS IMPORTANT INFORMATION Note To Supervisor: Please share this information with your employees and make sure they have received training

More information

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. blue**) fan blades are made from

More information

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS

400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS 12/11/07 PAGE 1 OF 12 400A 40113V, 401A 40120V, & 401AL 40120VL ALUMINUM VERTICAL 4000 LB LIFT INCLUDES SCREW LEG ASSEMBLY INSTRUCTIONS Thank you for purchasing our product! *Please read these instructions

More information

CONTROLS KIT FOR ALL # & # HARLEY DAVIDSON SPORTSTER MODELS

CONTROLS KIT FOR ALL # & # HARLEY DAVIDSON SPORTSTER MODELS INSTALLATION INSTRUCTIONS TC BROS. CHOPPERS PART #0-0075 & #0-0076 (No Pegs) FORWARD CONTROLS KIT FOR ALL 00-0 HARLEY DAVIDSON SPORTSTER MODELS If downloading & printing these instructions online, be sure

More information

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards. Installation Instructions for Fortress Horizontal Cable Panel System with UB-05 Brackets and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and to obtain all

More information

Penstocks.

Penstocks. Penstocks www.hambaker.co.uk 15 Reasons Why customers choose Ham Baker Hartley Business Philosophy Integrity in management Quality of product HISTORY HAM BAKER is a name most professionals in the water

More information

Tuf-Lite III Fans 3000K Series Hub

Tuf-Lite III Fans 3000K Series Hub Tuf-Lite III Fans 3000K Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

200 x x 3000mm

200 x x 3000mm 200 x 200-3000 x 3000mm Flow Control Crew NSW Penstocks and Stopboards are used for the isolation and control of water, wastewater, stormwater, drainage, water level and spillways. www.crewnsw.com Features

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

Reliance SG800 Series Steel Water Gage Valves

Reliance SG800 Series Steel Water Gage Valves Installation, Operation, & Maintenance Instructions R500.541D1 10/16/2016 Reliance SG800 Series Steel Water Gage Valves Note: Design variations in Steel Water Gage Valves necessitate typical illustrations,

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. Blue**) are made from fiberglass

More information

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO.

ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. ADDENDUM NO. 1 TO THE CONTRACT DOCUMENTS AND SPECIFICATIONS DATED JULY 2017 FLORIDA GOVERNMENTAL UTILITY AUTHORITY PROJECT NO. PS 061 SEVEN SPRINGS WASTEWATER TREATMENT FACILITY IMPROVEMENTS PASCO COUNTY,

More information

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub Tuf-Lite II Fans H Hi Temp 3000HT Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II Hi Temp Fan Blades Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Hi Temp fan blades (Red) are

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information

Leveling Feet, Base Plates and Casters

Leveling Feet, Base Plates and Casters Leveling Feet, Base Plates and Casters 77 Leveling Foot 1 1 Fastening to profile end Fastening in T-slot of profile For leveling tables and light equipment. Ratchet-type height adjustment requires no tools.

More information

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS USACE / NAVFAC / AFCESA / NASA UFGS-33 34 13 (April 2008) -------------------------- Preparing Activity: USACE Superseding UFGS-33 34 13 (April 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS References

More information

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards. Installation Instructions for FortressCable H-Series Stair Panels with Simplified Stair Bracket SSB-05 and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and

More information

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision

Pipe Restraints and Adapter Flanges. Section U. For PVC, Ductile Iron and Steel Pipe. 09/2017 Web Revision DQS Inc. THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001:2015 10004466 Section U 09/2017 Web Revision 11-29-17 Restraints and Adapter Flanges For PVC, Ductile Iron and Steel Contents Applications

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

Tuf-Lite II Fans 3000HC Series Hub

Tuf-Lite II Fans 3000HC Series Hub Tuf-Lite II Fans 3000HC Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 8 through 10 Diameter Hudson Tuf-Lite II (White) are made from fiberglass reinforced vinyl-ester

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.

More information

SECTION THERAPEUTIC POOL ACCESSORIES

SECTION THERAPEUTIC POOL ACCESSORIES PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 13 17 23.11 THERAPEUTIC POOL ACCESSORIES SPEC WRITER NOTES: Delete between // // if not applicable to project. Also, delete any other item or paragraph not applicable

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section.

FUEL GAS PIPING SECTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. FUEL GAS PIPING SECTION 15355 PART 1 GENERAL 1.1 DESCRIPTION A. The provisions of SECTION 15010, MECHANICAL GENERAL REQUIREMENTS, apply to this section. B. This specification covers both interior and exterior

More information

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8 September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

This specification describes the minimum requirements for piping systems for the following service:

This specification describes the minimum requirements for piping systems for the following service: SPEC-3501 1/ 1.0 APPLICATION This specification describes the minimum requirements for piping systems for the following service: Instrument Air Design Conditions 150 PSIG @ 180 F Operating Conditions 125

More information

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III Hi Temp (Red) fan blades are of single

More information

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards.

Fortress Fe Posts must always be secured to the deck framing. Fortress Fe Posts should never be attached to only the deck boards. Installation Instructions for FortressCable H-Series Cable Panel System With UB-05 Brackets and Fe Posts It is the responsibility of the installer to meet all code and safety requirements, and to obtain

More information

Product Guide Specification

Product Guide Specification Zurn Industries, LLC November 2014 1801 Pittsburgh Avenue Erie, PA 16502 Toll Free (855) 663-9876 Phone (814) 455-0921 Fax (814) 871-6141 Website www.zurn.com Product Guide Specification Specifier Notes:

More information

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS

NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS SECTION 15062 NON-PENETRATING ROOFTOP HANGERS AND SUPPORTS For best results, display hidden notes to specifier. PART 1 GENERAL 1.1 SECTION INCLUDES A. Pipe supports. B. Conduit supports. C. Duct supports,

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence MILWAUKIE OR #3144-00 ADDENDUM #5 NARRATIVE: 11-08-12 WAL-MART SUPERCENTER #3144-00; Milwaukie, OR: SPECIFICATIONS SPECIFICATIONS Revisions to Specification 02822 Fence Spec division 02822 has been revised

More information

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. RIGGING ACCESSORIES Color coded to distinguish between UNC (Red) and Metric (Silver) thread types. Available in UNC and Metric thread sizes. UNC threads available in sizes from 800 pounds to 100,000 pounds,

More information

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP. FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

SERIES 40 (WEIR GATES) INSTALLATION AND MAINTENANCE MANUAL (Revision 1)

SERIES 40 (WEIR GATES) INSTALLATION AND MAINTENANCE MANUAL (Revision 1) SERIES 40 (WEIR GATES) INSTALLATION AND MAINTENANCE MANUAL (Revision 1) 1. TABLE OF CONTENT 1. Table of content... 2 2. Introduction... 4 2.1. Warnings... 4 3. Receiving... 5 4. Storage... 5 5. Glossary

More information

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models

Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Sturdi-Wall Design Manual for SW46, SW66, SW63, SW64, SW60, SW83, SW84, and SW80 Models Project Number ME086-05 by Brent Leatherman, P.E. Timber Tech Engineering, Inc E-Mail: bl@timbertecheng.com January

More information

New Product Release: October 2014 Boone Racks

New Product Release: October 2014 Boone Racks New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance

More information

Evaluation of In-Pavement Light Fixture Designs and Performance

Evaluation of In-Pavement Light Fixture Designs and Performance Evaluation of In-Pavement Light Fixture Designs and Performance Presented to: IES ALC Fall Technology Meeting By: Joseph Breen Date: Background In-Pavement Light Fixture Assemblies Utilize a Circle of

More information

SECTION FOLDING GLASS PANEL PARTITIONS

SECTION FOLDING GLASS PANEL PARTITIONS SECTION 10 22 26.35 FOLDING GLASS PANEL PARTITIONS USE THIS SECTION WHEN SPECIFYING OVERHEAD SUPPORTED FOLDING GLASS PANEL PARTITIONS. SECTION INCLUDES OVERHEAD TRACK ASSEMBLY, MOUNTING BRACKETS, MOUNTING

More information

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation

Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...

More information

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards. B. See Division 5 Section "Pipe and Tube Railings"

More information

S W E RV E RAC K. Simple Security. Simple Stability.

S W E RV E RAC K. Simple Security. Simple Stability. S W E RV E RAC K Simple Security. Simple Stability. The Swerve Rack is a proven design that provides high security and easy bike parking. The Swerve Rack uses thick pipe construction and the full radius

More information

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105 BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105 These assembly instructions are to be used as a general reference guide to facilitate assembly. Please consult the blower, bushing, sheave,

More information

NAVSEA STANDARD ITEM

NAVSEA STANDARD ITEM NAVSEA STANDARD ITEM FY-19 DATE: 01 OCT 2017 CATEGORY: I 1. SCOPE: 1.1 Title: Threaded Fastener Requirements; accomplish 2. REFERENCES: 2.1 Standard Items 2.2 S9086-CJ-STM-010/075, Fasteners 3. REQUIREMENTS:

More information

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION NOTE: This special provision is generally written in the imperative mood. The subject, "the

More information

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe.

Section COUPLINGS AND COUPLING ADAPTERS. This Section covers couplings and coupling adapters for ductile iron and steel pipe. PART 1 GENERAL 1.01 SUMMARY Section 15155 This Section covers couplings and coupling adapters for ductile iron and steel pipe. 1.02 MEASUREMENT AND PAYMENT A. No separate payment for Work performed under

More information

UP4 LEARN-A-LOT (PLAYFUL) Parts List DESCRIPTION 90 ANGLE BRACKET DOOR WINDOW MUSIC CATERPILLAR CIRCLE FRAME CIRCLE MIRROR YELLOW STAINED GLASS RED STAINED GLASS SQUARE TRIANGLE SPIRAL WHEEL SQUARE MIRROR

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ROOF ACCESSORIES. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 07720 ROOF ACCESSORIES PART 1 GENERAL 1.1 SECTION INCLUDES Display hidden notes to specifier. (Don't know how? Click Here) A. Attachment clamp system for standing seam metal roofs. B. Attachment

More information

A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements.

A representative from Occupational Health is to be involved in the commissioning process to address any Respiratory Protection Program requirements. SPEC-3017 1/8 1.0 PURPOSE This specification describes the minimum requirements for the installation of breathing air distribution systems (indoor and outdoor) up to the connection to the breathing air

More information

A. Extent of structural precast concrete work is shown on drawings and in schedules.

A. Extent of structural precast concrete work is shown on drawings and in schedules. SECTION 03 41 00 - STRUCTURAL PRECAST CONCRETE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification

More information