24" Dia. 36" Dia. WE BUILD CONFIDENCE
|
|
- Roger Mosley
- 5 years ago
- Views:
Transcription
1 WE BUILD CONFIDENCE
2 WE BUILD CONFIDENCE PRECAST STRUCTURES SERVE AS KEY COMPONENTS OF OUR UTILITY AND TRANSPORTATION INFRASTRUCTURE. AND MAKING THE INDUSTRY S BEST PRECAST PRODUCTS TAKES DEDICATION, ATTENTION TO DETAIL AND HIGH STANDARDS FOR QUALITY AND SAFETY. For over forty years, Utility Vault has been recognized for our wide range of precast concrete products and custom solutions for the utility, environmental and transportation markets. Based in Auburn, Washington and a part of Oldcastle Precast, we ve built a reputation for quality and confi dence by constantly raising the bar to meet our customer s needs. We consistently offer outstanding customer service, exceptional product manufacturing and design expertise. But we build more than precast concrete products. We build confidence with our customers, every day. QUALITY PRODUCTS, MADE RIGHT At Utility Vault, we pride ourselves on exceeding the highest standards for product quality. We earned a Quality Control Certifi cation rating from the National Precast Concrete Association, and we have three full-time ACI-certified employees dedicated to quality control. We test our concrete daily to monitor the integrity of the mix and inspect the integrity of custom jobs during the fabrication process. And all of our products are stamped for approval before shipment. We also offer state-of-the-art equipment and facilities to accommodate our customer s precast and custom product needs. Our 130,000 square foot facility includes an 110,000 square foot precast production building featuring seven cranes, as well as a state-of-the art concrete mixing system. We also have a 20,000 square foot metal fabrication building that houses our production welders, along with a robotic welder and a plasma cutter. This part of our facility focuses on making metal frames and doors, as well as custom doors and miscellaneous metal fabrication. And our 43-acre product yard serves as a warehouse area for our vast product inventory. EXCEPTIONAL CUSTOMER SERVICE Our focus on customer needs begins when a request for an estimate is made. Our sales staff helps customers select the right solution and process their order quickly and effi ciently. When a custom item is required, our design experts can create a tailored solution based on a standard precast product or completely from scratch. We can also deliver detailed CAD drawings and consult on product installation as needed. We manage our precast product inventory and shipping schedule to provide timely supply and delivery. Our local customers rely on our crew of professional drivers and boom trucks to safely deliver and set most vaults directly in the hole. And no delivery site is too far away we fi ll both regional and overseas orders on a regular basis. COMMITTED TO PEOPLE AND SAFETY While our quality standards are important, the reason we re the precast concrete market leader is our people. We show our commitment to people by maintaining an exceptionally clean and safe workplace. Our facility is recognized by WISHA and OSHA for its top-level safety program, and has been recognized as a Voluntary Protection Program Star facility, the highest rating possible. This marks Utility Vault as the fi rst precaster in the United States to earn VPP Star status. A HISTORY OF INDUSTRY EXPERIENCE Over the years, Utility Vault has grown to meet the changing demands of our customers and regulators. In 1999, we added square footage and equipment to our precast building, while setting new standards for cleanliness and safety. We also improved our operations to meet and exceed changing environmental standards. Our goal is to make a positive impact on our community, and to provide real value for our employees and our customers.
3 UTILITY VAULT HAS BUILT ITS REPUTATION FOR QUALITY AND CUSTOMER CONFIDENCE BY OFFERING A WIDE RANGE OF QUALITY PRECAST CONCRETE PRODUCTS AND CUSTOM STRUCTURES. We build and deliver an extensive array of items such as vaults, lamp pole bases and oil/water separators to clients on a regional and national basis. At the same time, our engineering team can work with you to develop custom precast solutions to meet your specifi c project needs. We are committed to making the best quality precast products in the industry, supported by our expertise in customer service and installation. Our sales professionals are ready to answer your questions about any of the products shown or to discuss your custom design needs. TELEPHONE VAULT Our customers in the telephone industry typically use our vaults to splice traditional phone cable and fi ber optics, and we offer a wide range of telephone vaults in stock sizes for almost any application. Telephone vaults can include termaducts for easy conduit placement. We can incorporate custom slots and blockouts for special installations or intercepts, and include inserts for mounting racking. We also offer options such as pre-packaged racking and riser rings, along with ladder and manhole steps. In addition, we include boom truck placement for most telephone vault sizes. ELECTRICAL VAULT Our electrical vaults house power cables and transformers, and are a preferred alternative to running electrical power cables above the ground, and across utility poles. Electrical vaults represent our widest product range, and all of our standard vault sizes can be customized with optional blockouts and knockouts as needed to accommodate all site conditions. We also offer a variety of frames and access hatch options to meet exact project specifi cations. WATER VAULT Our customers use water vaults for the underground installation of water meters, detector check valves for sprinkler systems, pressure-reducing valves and backfl ow prevention valves. We can custom engineer our water vaults to meet job-specific applications, and we offer a vast number of sizes. We have the production capabilities to core drill these vaults and make them installation-ready. To further facilitate quick and easy installation, we can also apply both interior and exterior coatings in-house when necessary. 24" Dia. 36" Dia.
4 OUR PRODUCTS LAMP POLE BASE Our precast lamp pole bases provide a cost-effective and effi cient alternative to the traditional cast-in-place method. We supply a wide variety of standard lamp pole bases to fi t our customer s needs, and can easily confi gure bases to meet custom design specifi cations. We can also position customersupplied anchor bolts to the specifi ed bolt circle diameter. Our production facility is designed so we can pour numerous bases to meet fi eld requirements. Our ability to build to any specifi cation means that our customers don t have to pour in the fi eld. PANEL VAULT We offer panel vaults to our customers when standard vault sizes don t meet their specifi c needs, or when job requirements call for a special vault size. In fact, we will often work with a customer to visit the job site to determine what type of design will work, and then custom build a solution. We provide these vaults as individual slab components so they can be assembled on-site, giving our customers fl exibility beyond that of a castin-place vault. Our custom fabrication and expert installation assistance can save our customers time and money for these types of applications. OIL/WATER SEPARATOR Our oil/water separators work to protect the environment by intercepting grease and oil in storm water runoff before it can escape into a local water or sewer system. We offer two styles of oil-water separators baffl e type and coalescing packs in a wide range of sizes. In addition, we offer grease separators in a 750 gallon size and larger. DRAINAGE We supply a number of drainage products to meet customer needs, including catch basins and manholes for storm and sewer applications. Besides offering an array of standard drainage products, we can also tailor knockout sizes and locations to meet unique job specifi cations. All of our drainage products meet ASTM and all WSDOT/APWA specifi cations to ensure product quality and code compliance. 24" Dia. 36" Dia.
5 24" Dia. TRENCH/CULVERT Customers use our precast utility trenches and culverts in all types of power, communications, and stream or water conveyance projects, including housing piping, electrical and communications wiring, and even fi sh ladders. We offer various sizes and confi gurations to meet virtually any need, and provide our customers with a wide range of frames and access hatches. BRIDGE/DETENTION We use our three-sided box sections to create short-span bridges, with spans of 10 to 35. In addition, we build detention vaults from either our three-sided box sections or from our panel vault system. Since we construct these solutions from multiple sections, we can customize their lengths as needed. We can also skew the bridge to conform to specifi c site conditions. Our pre-engineered product system provides fast on-site construction, while complying with all local and state specifi cations. BARRIER Our median barriers can be seen on roads and highways across the region, and are used extensively by our local transportation industry. We offer all sizes and styles of precast WSDOT barriers, including Type II, Type IV, Type V, Single Slope and Single-Sided Single Slope. We keep a vast inventory of median barriers on hand to provide 24-hour fulfi llment to our customers. CUSTOM PRODUCTS Our extensive experience providing high quality precast products, along with our sales and engineering expertise, allow us to work with customers in designing custom solutions. We also have the production capacity to modify standard products and fabricate many special applications. We pride ourselves in developing solutions large and small for all types of projects, and are always ready to provide custom products to our customers. 24" Dia
6 UTILITY VAULT, AUBURN FACILITY 1 Utility Vault Main Office 4 Loading Area 2 Form Building 5 Assembly Building 3 Precast Plant 6 Metal Fab Facility 46" Dia. 36" Dia. Street Address 2808 A Street SE Auburn, WA Mailing Address PO Box 588 Auburn, WA Phone: Fax: uvauburn@oldcastleprecast.com 2005 Utility Vault. All rights reserved. This product is for informational purposes only. UTILITY VAULT MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, IN THIS SUMMARY. Utility Vault and the UV logo are either registered trademarks or trademarks of Oldcastle Precast, Inc.
Pipe Product Catalog Table of Contents
Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48"
More informationshawprecastsolutions.com BEBO Arch Systems PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions.
shawprecastsolutions.com BEBO Arch Systems PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. BEBO ARCH SYSTEMS BEBO ARCH units are high quality, low maintenance precast structures
More informationDelivering Reliability. Services. Strength You Can Count On. oldcastleprecast.com/services
Delivering Reliability A Strength You Can Count On SERVICES TENANT IMPROVEMENTS Above And Below Ground Solutions Strength You Can Count On Oldcastle Precast is well trained and knowledgeable in all aspects
More informationALL YOUR PRECAST SOLUTIONS
PO Box 265 Waverly, WV 26184 304-464-4441 ENERGY PRODUCTS ALL YOUR PRECAST SOLUTIONS UP STREAM MID STREAM DOWN STREAM Carr Concrete began in 1974 as Marietta Wilbert, Inc. of Marietta, Ohio. The only product
More informationABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing
ABOUT INLAND Inland roots in the Winnipeg area date back to the early 960 s. Over time, through a number of mergers and acquisitions Inland Pipe is now part of the Lehigh Hanson group in North America
More informationStandard Specifications
Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and
More informationMH Table of Contents Standard Title/Scope Page Table of Contents SCE Public
MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................
More informationManholes Table of Contents
Standard MH 300 Title Manholes Requirements MH 300.1 Manholes Requirements Manholes Table of Contents Underground Structures Standards MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Precast Tub-Type
More informationSTATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1073 PRECAST CONCRETE CERTIFICATION PROGRAM JULY 20, 2018
STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1073 PRECAST CONCRETE CERTIFICATION PROGRAM JULY 20, 2018 1073.01 Program Overview 1073.02 Qualification 1073.03 Documentation Phase 1073.04 Documentation
More information2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard
More informationManhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard
More informationSECTION PRECAST CONCRETE STRUCTURES
SECTION 02605 PRECAST CONCRETE STRUCTURES PART 1 GENERAL 1.01 DESCRIPTION A. CONTRACTOR shall provide all professional services, labor, materials, equipment and incidentals as shown, specified and required
More informationSUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-01) MANUAL: Standard
More informationStandard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.
DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard
More informationCustomer Connection Guide Updates Effective May 2017
This document provides a list of the updates to the EPCOR Distribution and Transmission Inc. (EDTI) Customer Connection Guide. If you have any questions, please contact EDTI Customer Engineering Services
More informationSection E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02
Section E NSPS MODEL STANDARDS FOR TOPOGRAPHIC SURVEYS Approved 3/12/02 1. INTRODUCTION This standard is written to provide the professional surveyor (Surveyor) and the client with a guideline for producing
More informationMAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX
407-1 - MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1.1 GENERAL Tender Items Specifications Standard Drawings 407-1.1.1 Frame and Grate Selection 407-1.1.2 Selection of Structure
More informationUtility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles
Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. UTILITY STRUCTURES Perfect
More informationStormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18
StormTrap Guide Specification StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 This product guide specification is written according to the Construction Specifications Institute
More informationSUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-03) MANUAL: Standard
More informationCooke Precast Concrete
Cooke Precast Concrete INSPECTION OPENINGS History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience
More informationINSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September
More informationExisting and proposed contours at 1-foot intervals. The fill and/or excavation quantities in cubic yards.
PLAN REQUIREMENTS The plans for street design shall conform to the requirements of Sections 3 and 4. The following requirements shall also be shown on the plans where applicable. Road and Storm Plans:
More informationPART 4 STANDARD DRAWINGS FOR CONSTRUCTION
4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of
More informationAnti-Trust Statement
Anti-Trust Statement http://www.concrete-pipe.org/ A joint effort of the Texas Concrete Pipe Association and the Texas Department of Transportation What brought this about? The TxDOT organization consists
More informationINSTALLATION INSTRUCTIONS FOR BALCO, INC. NBR SERIES EXPANSION JOINT COVER SYSTEMS
2626 South Sheridan PO Box 17249 Wichita, Kansas 67217 Phone: (316) 945-9328 Fax: (316) 945-0789 INSTALLATION INSTRUCTIONS FOR BALCO, INC. NBR SERIES EXPANSION JOINT COVER SYSTEMS 2010, Balco, Inc. 09/14/10
More informationDESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA
DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA 94544-1395 PUBLIC WORKS DESIGN GUIDELINES TABLE OF CONTENTS SD-100 SERIES SPECIAL DRAWINGS SD-100 8/1991 SILT
More informationSUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard
More informationSUPPLEMENTARY STANDARD DETAIL DRAWINGS
CITY OF MAPLE RIDGE DESIGN AND CONSTRUCTION DOCUMENTS Part 4 SUPPLEMENTARY STANDARD DETAIL DRAWINGS September 2015 Updated: October 2015 THIS PAGE INTENTIONALLY LEFT BLANK City of Maple Ridge Supplementary
More informationGovernment Of Newfoundland & Labrador Municipal Water, Sewer And Roads Master Construction Specifications
PAGE NO. : 1 OF 4 Revision Date: July 2009 STANDARD DRAWINGS TABLE OF CONTENTS DRAWING # DESCRIPTION 0030............ Work Adjacent to Roadway 0040............ Work at the Edge of Roadway 0050............
More informationKANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION
Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION NOTE: This special provision is generally written in the imperative mood. The subject, "the
More informationEngineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings
Engineering and Construction Services Division Construction Drawings for Sewers and Watermains Revision No. 8 April All T drawings New title block for each drawing is now standardized. Revision numbers
More informationPRODUCT CATALOGUE. Saskatchewan
PRODUCT CATALOGUE Saskatchewan From Cover Victoria Avenue (TransCanada Hwy ) is the primary entrance into the east side of Regina, SK and has over 40,000 vehicles per day travelling on it. The existing
More informationMANHOLES PART I: GENERAL. A. Precast Concrete Manholes
MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a
More informationCooke Precast Concrete
Cooke Precast Concrete History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience within the precast
More informationREQUIRES LESS LABOR MADE NESTS TOGETHER FOR LOW COST SHIPPING UNIVERSAL MOUNTING MADE IN THE USA LOWER FREIGHT MESSENGER WIRE NO SHARP EDGES
REQUIRES LESS LABOR MADE IN THE USA LOWER FREIGHT COSTS NESTS TOGETHER FOR LOW COST SHIPPING UNIVERSAL MOUNTING SUSPENDS WITH MESSENGER WIRE NO SHARP EDGES LOWER CONSTRUCTION COSTS BY 30% REQUIRES LESS
More informationMaverick Inspection Ltd. has been pioneering specialized non-destructive testing in Western Canada
TECHNOLOGY, EXPERTISE & SOLUTIONS Maverick Inspection Ltd. has been pioneering specialized non-destructive testing in Western Canada since 1994. As a Canadian-owned and operated company, we have earned
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-04) MANUAL: Standard
More informationcivil product range JUNCTION BOXES DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS
kilform civil product range ESB CCTV Eircom Services Lighting Risers DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully Headwalls
More informationCooke Precast Concrete
Cooke Precast Concrete ACCESS COVERS History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience within
More informationOverview of Precast ABC Projects in the Pacific Northwest. Chuck Prussack, P.E., Oldcastle Precast, Inc - Spokane
Overview of Precast ABC Projects in the Pacific Northwest Chuck Prussack, P.E., Oldcastle Precast, Inc - Spokane 1 Techniques Additional prefabrication of units to reduce field timeline Simplify deck installation
More informationSTANDARD SPECIFICATIONS SECTION PRECAST CONCRETE 1.2 REQUIREMENTS FOR MANUFACTURERS AND SUPPLIERS BEFORE DELIVERY
STANDARD SPECIFICATIONS SECTION 03400 PRECAST CONCRETE PART 1 GENERAL 1.1 DESCRIPTION A. Section includes requirements for providing precast concrete structures, manholes, valve vaults, and other specified
More informationSection. DEVELOPMENT STANDARDS City of Ellensburg ILLUMINATION STANDARDS
Section 8 City of Ellensburg ILLUMINATION STANDARDS Table of Contents STREET ILLUMINATION...3-5 GENERAL NOTES...3 INSTALLATION AND CONNECTIONS...3 MARKING...3 STAKING...3-4 TRENCH REQUIREMENTS...4 ILLUMINATION
More informationThe New Power in Surface Preparation
The New Power in Surface Preparation Expanding the Possibilities Equipment Aftermarket Rebuild & Upgrade Sales & Service Aerospace Agriculture Automotive Defense Energy & Power Generation Forge & Foundry
More informationSECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings
SECTION 095 SPECIFICATIONS DETAIL DRAWINGS Index of Detail Drawings Flat Top Manhole... 095-1 Splash Drop Manhole and Regular Drop Manhole... 095-2 Special Detail Splash Drop Manhole and Special Detail
More information2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"
Scope.1 Precast Concrete Equipment Slab Box 8' x 10' x Pad with 4' x 7' x 3'- Box for 5-Way RAM Gas Switch, 2-Way, 3-Way, and 4-Way Pad-Mounted RAG Gas Switches, VFI 9, VFI 12, Bypass Switch, and 33 kv
More informationStandard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (13-03) MANUAL: Standard
More informationCity of Vaughan Engineering Department DESIGN STANDARD DRAWINGS
City of Vaughan Engineering Department DESIGN STANDARD DRAWINGS March 2004 STANDARD DRAWINGS Partners With The Environment March 2004 FORWARD The March 2004 version of the City of Vaughan Design Standard
More informationCITY OF LA MARQUE CHAPTER GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS
CITY OF LA MARQUE CHAPTER 2 -------------------------------------------- GRAPHIC REQUIREMENTS CONSTRUCTION PLAN AND MISCELLANEOUS REQUIREMENTS CHAPTER 2 ------------------------------------------------
More informationB17. Sewer Site Plans BULLETIN
BULLETIN B17 Revised 5/2/2016 Sewer Site Plans Public Works This bulletin is designed to assist you in submitting the required documentation for sewer site plans to the Pierce County Sewer Division in
More informationCity of Massillon Site Plan Checklist
City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete
More informationPioneers in Gate Design
Stop Logs Pioneers in Gate Design Hydro Gate 3888 E. 45th Ave. #120 Denver, CO 80216 Your Source for Water Control Gates No matter what type of gates your project demands, chances are excellent Hydro Gate
More informationA. Suggested Tool List
These instructions are intended to be a basic guide to the installation and assembly of plate structures. Job site specific conditions may require other procedures. A Statement on Safety The assembly procedure
More informationFacility Services Subgroup Preface for Divisions 21` through 28
Facility Services Subgroup Preface for Divisions 21` through 28 1.1 EXECUTIVE SUMMARY A. This document provides standards for the Consultants and Contractors producing mechanical and electrical design
More informationSECTION III SUBMITTALS AND APPROVALS
SECTION III SUBMITTALS AND APPROVALS In order to expedite the approval process of new water distribution system and sanitary sewer collection system extensions, the Hilton Head No. 1 Public Service District
More informationStormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17
StormTrap Guide Specification StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17 This product guide specification is written according to the Construction Specifications
More informationA. Deviation from this standard must be approved by the Project Architect.
September 2012, rev. 00 26 5600 Exterior Lighting PART 1. GENERAL 1.01 Related Documents A. Deviation from this standard must be approved by the Project Architect. B. Drawings and general provisions of
More informationSurvey Requirements. Design Guidelines and Standards. June Office of the University Architect
Design Guidelines and Standards Survey Requirements June 2004 Office of the University Architect Construction Management P.O. Box 210181 Cincinnati, Ohio 45221-0181 Table of Contents Survey Requirements
More informationMy Company. Simply Safe.
More inside. All from a single source. In order to offer tailor-made services regionally and internationally, we have organized the TÜV AUSTRIA Group into four business areas: Industry & Energy Infrastructure
More informationThe Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8
September 2013 Page 1 of 8 Part 1 General 1.1 DESCRIPTION OF WORK.1 The work described herein shall consist of the construction of air release chambers, flushout chambers, valve chambers, meter chambers
More informationUTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1
UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.
More informationAUTOMOTIVE FASTENING TECHNOLOGY SPOKEN HERE.
AUTOMOTIVE FASTENING TECHNOLOGY SPOKEN HERE. ALCOA FASTENING SYSTEMS & RINGS. DRIVING AUTOMOTIVE FASTENING TECHNOLOGY FOR MORE THAN 5 DECADES. At Alcoa Fastening Systems & Rings (AFSR), we understand automotive
More informationD. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC
STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,
More informationSTANDARD DETAILS Crow Canyon Road San Ramon, CA Telephone: (925) Fax: (925)
STANDARD DETAILS 2401 Crow Canyon Road San Ramon, CA 94583 Telephone: (925) 973-2670 Fax: (925) 838-3937 CITY OF SAN RAMON STANDARD DETAILS INDEX CONCRETE WORK NAME DRAWING # Curb, Gutter & Sidewalk C-1
More informationINSTALLATION INSTRUCTIONS FOR BALCO, INC. BRONZE STAIR NOSINGS
2626 South Sheridan PO Box 17249 Wichita, Kansas 67217 Phone: (316) 945-9328 Fax: (316) 945-0789 INSTALLATION INSTRUCTIONS FOR BALCO, INC. BRONZE STAIR NOSINGS 2005, Balco, Inc. Revised 12/08/05 Document
More information5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.
2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc
More informationRecord Drawing Standards for Projects Version 2.1
for Projects Version 2.1 Updated September 21, 2016 Department: Spatial Data Group Engineering & Maintenance 1. INTRODUCTION... 1 2. GENERAL STANDARDS... 1 2.1 Drawing Standards... 1 2.2 Digital Submission
More informationACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS
ACWWA DRAWING SUBMITTAL INFORMATION - UTILITY DRAWING REQUIREMENTS Detailed construction drawings for system extensions shall be prepared for approval with a submittal to the Authority. All construction
More informationApplication for Site Plan Review
Application for Site Plan Review 3275 Central Blvd., Hudsonville, Michigan 49426-1450, 616.669.0200 fax 616.669.2330 It is STRONGLY recommended that any application that must go before the Planning Commission
More informationFRANKLIN BRONZE PRECISION COMPONENTS
FRANKLIN BRONZE PRECISION COMPONENTS FRANKLIN BRONZE PRECISION COMPONENTS AN AUTOMATED INVESTMENT CASTING FOUNDRY OFFERING TOOLING, MACHINING AND TECHNICAL EXPERTISE. DELIVERING HIGH-QUALITY, CONSISTENT
More informationCurrent Standard Plates including Transmittal Letters are available on the web at:
MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (15-03) MANUAL: Standard
More informationSECTION MANHOLES
SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard
More informationSPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS
SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS 1. DESCRIPTION THESE SPECIFICATIONS ARE FOR A PRECAST THREE SIDED ARCH STRUCTURE, HEADWALLS
More informationTurning the wheels of your success
INDUSTRIAL SERVICES Turning the wheels of your success A comprehensive package of integrated services combining traditional certification and inspection with innovative business solutions based on the
More informationSECTION PRECAST CONCRETE SECTIONAL MANHOLES
SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,
More informationSECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 051200 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationSAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT. Addendum No. 2
SAUSALITO-MARIN CITY SANITARY DISTRICT MISCELLANEOUS UPGRADES PROJECT Addendum No. 2 The following shall modify the Contract Documents. The work shall be accomplished in accordance with such modifications.
More informationFACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES
KISTNER CONCRETE PRODUCTS, INC. 8713 READ ROAD EAST PEMBROKE, NEW YORK 14056-0218 PH: 585-762-8216 FX: 585-762-8315 FACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES ASTM C-478 ASTM C-443 KISTNER
More informationPlate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.
DISTRIBUTION: 7 MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Design Services Section TRANSMITTAL LETTER NO. (0-0) MANUAL: Standard Plates DATED: January 9, 00 SUBJECT:
More informationCooke Precast Concrete
Cooke Precast Concrete STORMWATER History Cooke Precast Concrete Pty. Ltd. commenced business in September 1996, with a staff combining together bringing many decades of knowledge and experience within
More informationPLAY HOUSE IMPORTANT
IMPORTANT Page 1 PLEASE READ THESE INSTRUCTIONS BEFORE COMMENCING ASSEMBLY. All equipment must be installed in accordance with these instructions. Check your shipment against Bill of Lading and Parts list.
More informationCreated from more than 25 years of experience.
Created from more than 25 years of experience. The OneLift by Oldcastle Precast, provides a standard turnkey submersible pump station product with the distinction of having a sole-source point of responsibility.
More informationWaukesha Foundry. Industry Experience Engineering Expertise
Waukesha Foundry Industry Experience Engineering Expertise Advanced Technology Experience an Industry Leader Waukesha Foundry has earned a reputation as an innovator in the production of high-quality cast
More informationCS3 represents manufacturers of products for use in the municipal waterworks industry.
Brian Drexel & Rob Grier WWW.CS3WATERWORKS.COM Established in 2000, CS3 Waterworks is a Florida Based company with offices in Orange Springs Florida and Savannah Georgia. CS3 represents manufacturers of
More informationLet s collaborate. Better Gather Develop Testing product, data material longer life Helwig Carbon Quality
Helwig Carbon pioneered carbon brush technology 80 years ago, and our staff of more than 230 dedicated employees keep that spirit of innovation alive today. From our management team, engineering staff,
More informationPROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS. room) Scalable bubble diagrams schedules describing programmatic
GENERAL SITE PROGRAMMING SCHEMATIC DESIGN DESIGN DEVELOPMENT CONSTRUCTION DOCUMENTS Scope of work narrative Building code review Description of construction Documentation on drawings as List of applicable
More informationKEEP YOUR RESOURCE MOVING.
LINER BOLTS KEEP YOUR RESOURCE MOVING. COLUMBUS McKINNON CORPORATION Leading the Industry Downtime in the grinding mill operation is caused by one of two things: regularly scheduled maintenance or unscheduled
More informationOil-Water Separator Design Checklist
CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water
More informationWorld Class Fabrication and Machining Parts to Finished Assemblies
- Woman Owned Small Business - World Class Fabrication and Machining Parts to Finished Assemblies FABRICATION MACHINING POWDER COATING WET PAINTING PLATE PROCESSING WELDING FABRICATION MACHINING POWDER
More informationCAT-350 Product Manual
CAT-350 Product Manual Release 01/17 www.ingalcivil.co.nz CAT-350 NZ Assembly Manual Ingal Civil Products NZ 40 Tironui Road, Auckland 2112 www.ingalcivil.co.nz Important: These instructions are for standard
More informationINSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL
March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete
More informationPorter County Plan Commission
Plan Type: Development Plan Administrative DRC PC Primary Plan Administrative DRC PC Secondary Plat/Replat Administrative DRC PC PUD Conceptual Detailed Final Project Information Project Name: Developer
More informationMAST ARMS & POLES. Ornamental Pole Top & Bases
Ornamental Pole Top & Bases Pelco s decorative pole top and bases make the traffic signal aesthetically pleasing to the eye. In addition to the standar 4-piece, Pelco also manufactures the bases with an
More informationSECTION UNDERGROUND POWER DUCT AND SUB-STRUCTURES. A. Section : Trenching, Backfilling, and Compacting
SECTION 33 71 19 UNDERGROUND POWER DUCT AND SUB-STRUCTURES PART 1 GENERAL 1.1 RELATED WORK A. Section 31 23 33: Trenching, Backfilling, and Compacting B. Section 32 01 00: Site Restoration and Rehabilitation
More informationSECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS
SECTION 100 PRELIMINARY CONSIDERATIONS & INSTRUCTIONS 101 General 102 Submittal Requirements A. Initial Submittal B. Second Submittal 103 Plan Requirements A. Subdivisions B. Site Plans 104 Approval of
More informationUNDERGROUND AND UTILITIES
ARMTEC.COM UNDERGROUND AND UTILITIES WIDE RANGE OF UNDERGROUND AND UTILITY PRODUCTS DESIGNED FOR DEMANDING INFRASTRUCTURE AND MINING APPLICATIONS UNDERGROUND AND UTILITIES Armtec designs, manufactures
More informationInstallation and Assembly: Recessed Cable Management and Power Storage Accessory Box
Installation and Assembly: Recessed Cable Management and Power Storage Accessory Box Models: IBA3, IBA3-W 2300 White Oak Circle Aurora, Il 60502 (800) 865-2112 Fax: (800) 359-6500 www.peerlessmounts.com
More informationCITY OF WAPATO NORTH WAPATO LIFT STATION REPLACEMENT CITY OFFICIALS. JUAN OROZCO Mayor. ROBERTO REYNA Mayor Pro Tem
YAKIMA COUNTY WASHINGTON CITY OFFICIALS JUAN OROZCO Mayor ROBERTO REYNA Mayor Pro Tem TONY GUZMAN RALPH SANCHEZ TONY GAYTAN DORA ALVAREZ-ROA FRANK JAIME City Council KEITH WORKMAN ROBIN CORDOVA Clerk-Treasurer
More informationSECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.
SECTION 02082 PUBLIC UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular precast concrete manholes with tongue-and-groove joints, transition to cover frame, covers,
More informationQUALITY THROUGH EXPERIENCE-SINCE 1963
b y H a k o h a v V a l v e s P E N S T O C K S & F L A P V A L V E S by Hakohav Valves ABOUT US QUALITY RELIABILITY Kim Valves started up as Hakohav Valves in 1963 by two young visionary engineers who
More information