Pipe Product Catalog Table of Contents

Size: px
Start display at page:

Download "Pipe Product Catalog Table of Contents"

Transcription

1 Pipe Product Catalog Table of Contents Section A: Drawing #: Page Description A1 Reinforced Concrete Pipe A3 Storm Manhole Sizing Chart (48" - 96") A3.1 Storm Manhole Sizing Chart (108" - 144") A4 48" Diameter Storm Manhole A4.1 48" X 48" Square Storm Manhole A4.2 Type 46 Storm Inlet A5 60" Diameter Storm Manhole A6 72" Diameter Storm Manhole A7 Storm Reduction Manhole A8 Reduction Cover A9 Storm Tee Manhole A10 2' X 3' Storm Inlet Box A10.1 2' X 3' Storm Catch Basin A11 Median 1 Grate Inlet A12 Median 2 Grate Inlet A13 Median 2 Grate Inlet (with 72 Manhole) A13.1 Median 4 Grate Inlet A14 42" Diameter Storm Catch Basin A15 36" Diameter Storm Catch Basin A16 30" Diameter Storm Catch Basin A17 Small Storm Catch Basins A18 Concrete Apron Endwalls A RC Endwalls A Concrete Endwall A19 Concrete Elliptical Endwalls A x 98 RC Endwalls A x 106 RC Endwalls A x 113 RC Endwalls A x 121 RC Endwalls A20 Galvanized Trash Guards A21 Concrete Pipe Fittings Wyes, Tees & Transitions A22 Concrete Pipe Fittings Pipe Plugs / Caps & Fabricated Bends

2 Pipe Product Catalog Table of Contents (cont.) A26 A27 A29 A30 A31 6:1 Slope 18" Concrete Endwall 6:1 Slope 24" Concrete Endwall Precast Concrete Box Culvert Sizes Sheet Precast Concrete Box Culvert End Sections Hydroguard Stormwater Treatment Structure Section B: Sanitary Sewer Systems Drawing #: Page Description B1 Sanitary Manhole Sizing Chart B2 Standard Sanitary Manhole B3 Shallow Sanitary Manhole B4 Sanitary Reduction Manhole B5 Reduction Cover B9 Combined Lift Station (72 ) B10 Combined Lift Station (72 Cont.) B11 Combined Lift Station (96") B12 Combined Lift Station (96" Cont.) B13 Sanitary Drop Manhole Pieces

3 Drawing #: A1 Reinforced Concrete Pipe REINFORCED CONCRETE PIPE - ROUND - GASKET JOINT - ASTM C-76 INSIDE 1000-D 1350-D 2000-D 3000-D ENDWALL GALVANIZED ENDWALL PIPE WALL MAXIMUM DIAMETER CLASS II CLASS III CLASS IV CLASS V COST PIPE GRATES WEIGHT WEIGHT THICKNESS LOAD INCHES $ / FT $ / FT $ / FT $ / FT $ / EA $ / EA LBS LBS / FT INCHES FT / TRUCK 12" PLEASE CALL FOR PRICING " 384' 15" /4" 320' 18" /2" 240' 21" /4" 176' 24" " 144' 27" /4" 112' 30" /2" 104' 33" /2" 88' 36" " 72' 42" /2" 64' 48" " 48' 54" /4" 32' 60" /4" 32' 66" /4" 24' 72" /4" 16' 78" /4" 16' 84" " 16' 96" " 16' 108" " 8' 120" " 8' 144" PLEASE CALL FOR PRICING " 6' REINFORCED CONCRETE PIPE - ELLIPTICAL - MORTAR JOINT - ASTM C-507 HE - HORIZONTAL ELLIPTICAL VE - VERTICAL ELLIPTICAL RISE & EQUIV. 800-D 1000-D 1350-D 2000-D ENDWALL GALVANIZED PIPE WALL MAXIMUM SPAN ROUND HE-I HE-II HE-III HE-IV COST PIPE GRATES WEIGHT THICKNESS LOAD INCHES INCHES $ / FT $ / FT $ / FT $ / FT $ / EA $ / EA LBS / FT INCHES FT / TRUCK 14"x23" 18" PLEASE CALL FOR PRICING /4" 224' 19"x30" 24" /4" 128' 24"x38" 30" /4" 104' 29"x45" 36" /2" 72' 34"x53" 42" 850 5" 56' 38"x60" 48" /2" 40' 43"x68" 54" " 32' 48"x76" 60" /2" 24' 58"x91" 72" /2" 24' 72"x113" 90" PLEASE CALL FOR PRICING " 16' * CUSTOMER UNLOADS ALL HE & 96", 108", 120", * 3/4" JOINT TIE ASSEMBLY (12" RCP - 60" RCP) 144" PIPE * 1" JOINT TIE ASSEMBLY (66" RCP - 120" RCP) * ALL PIPE MANUFACTURED IN 6' & 8' LENGTHS ONLY. * ALL PRICES F.O.B. PLANT, FREIGHT ALLOWED WITHIN 75 MILES OF PLANT, DELIVERED TO NEAREST * GASKET LUBRICANT ACCESSIBLE POINT BY TRUCK UNDER ITS OWN POWER (NOT INCLUDED IN PIPE PRICE) IN TRUCKLOAD LOT. LESS THAN FULL LOADS SUBJECT TO A DELIVERY CHARGE. UNLOADING TIME IN EXCESS OF 1 HR $250 / HR * PRICES SUBJECT TO CHANGE WITHOUT NOTICE

4 Drawing #: A3 Storm Manhole Sizing Chart (48" - 96") MANHOLE DIAMETER 48" 18" MAXIMUM PIPE SIZE FOR PRECAST STRUCTURES STRAIGHT RIGHT ANGLE 18" RCP 24" RCP 24" RCP RCP 60" 24" 36" RCP 36" RCP 24" RCP RCP 36" RCP 72" 42" RCP 42" RCP 36" RCP 36" RCP 84" 48" RCP 48" RCP 42" RCP 42" RCP 96" 60" RCP 60" 42" RCP RCP PRECAST MANHOLE SIZING CHART SCALE: DATE: 1/8" = 1'-0" JANUARY 2008 PLATE: A3

5 Drawing #: A3.1 Storm Manhole Sizing Chart (108" - 144") MANHOLE DIAMETER MAXIMUM PIPE SIZE FOR PRECAST STRUCTURES STRAIGHT RIGHT ANGLE 54" RCP 108" 66" 54" RCP 66" RCP RCP (BASED ON 8'-0" RISER HEIGHT) 60" RCP 120" 72" 72" RCP RCP 60" RCP (BASED ON 8'-0" RISER HEIGHT) 144" PLEASE CALL FOR ASSISTANCE (6'-0" MAX RISER HEIGHT) SCALE: 1/8" = 1'-0" PLATE: PRECAST MANHOLE SIZING CHART DATE: JANUARY 2008 A3.1

6 Drawing #: A4 48" Diameter Storm Manhole 3'-0" CONE PRECAST CONE IF DEPTH ALLOWS 58" x 8" FLAT TOP W/ 27" OR 2' x 3' HOLE 5" WALL 48" DIA. CUTOUT VARIES PER RCP DEPTH VARIES PER PLAN 66" x 6" PRECAST BASE MH, TYPE 1) SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * SEE PRECAST MANHOLE SIZING CHART FOR MAXIMUM ALLOWABLE PIPE SIZE PER MANHOLE DIAMETER

7 Drawing #: A4.1 48" X 48" Square Storm Manhole 27" HOLE 60" x 60" x 8" FLAT TOP w/ 27" OR 2' x 3' HOLE 6" WALL 48" x 48" SQUARE CUTOUT VARIES PER RCP DEPTH VARIES PER PLAN (5'-2" MAX RISER) 72" x 72" x 8" PRECAST BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER

8 Drawing #: A4.2 4 x 6 Storm Inlet 27" HOLE 2' X 3' HOLE 4'-10" MAX VARIABLE 6'-0" 8" 8" 4'-0" 8" 12" 8" 100" 76" SPECIFICATIONS * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * #4 REINFORCING BARS 6" C-C BOTH WAYS IN BASE & FLAT TOP * #4 REINFORCING BARS 12" C-C BOTH WAYS IN RISER SECTIONS * RISER SECTION WEIGHT = 2300 LBS./VERT. FT. * PRECAST FLAT TOP SECTION 4000 LBS. * PRECAST BASE SECTION 5500 LBS. * NOTE: MAX. ALLOWABLE PIPE SIZE = 36" RCP SCALE: 3/8" = 1'-0" PLATE: TYPE 46 INLET DATE: JANUARY 2008 A4.2

9 Drawing #: A5 60" Diameter Storm Manhole 72" x 8" FLAT TOP W/ 27" OR 2' x 3' HOLE 6" WALL 60" DIA. CUTOUT VARIES PER RCP DEPTH VARIES PER PLAN 80" x 8" PRECAST BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * SEE PRECAST MANHOLE SIZING CHART FOR MAXIMUM ALLOWABLE PIPE SIZE PER MANHOLE DIAMETER

10 Drawing #: A6 72" Diameter Storm Manhole 86" x 8" FLAT TOP W/ 27" OR 2' x 3' HOLE 7" WALL 72" DIA. CUTOUT VARIES PER RCP DEPTH VARIES PER PLAN 94" x 8" PRECAST BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * SEE PRECAST MANHOLE SIZING CHART FOR MAXIMUM ALLOWABLE PIPE SIZE PER MANHOLE DIAMETER (D.O.T. MH, TYPE 3) SCALE: 3/8" = 1'-0" 72" DIAMETER STORM MANHOLE DATE: JANUARY 2008 PLATE: A6

11 Drawing #: A7 Storm Reduction Manhole 27" DIA. 3'-0" PRECAST CONE STOCK RISERS 1'-0", 1'-4", 2'-0" 2'-4", 2'-8", 4'-0" 5'-4" 48" DIA. SEE PLATE A8 60", 72", 84", 96", 108", 120", 144" DIAMETER 4'-0", 6'-0", 8'-0" TYP. CUTOUT VARIES PER RCP 4" MIN. 8" MIN. PER DIAMETER SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * SEE DETAIL FOR REDUCTION COVER DATA * SEE PRECAST MANHOLE SIZING CHART FOR MAXIMUM ALLOWABLE PIPE SIZE PER MANHOLE DIAMETER STORM REDUCTION MANHOLE SCALE: DATE: 3/8" = 1'-0" JANUARY 2008 PLATE: A7

12 Drawing #: A8 Reduction Cover VARIES 48" DIA. 10" THICK FOR 60", 72" 12" THICK FOR 84", 96" 14" THICK FOR 108", 120", 144" 60", 72", 84", 96", 108" 120", 144" DIAMETER MANHOLE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER

13 Drawing #: A9 Storm Tee Manhole PRECAST CONE IF DEPTH ALLOWS 58" x 8" FLAT TOP W/ 27" OR 2' x 3' HOLE (6'-0" FOR 144") 8'-0" 48" DIA. MH RISER 4'-0" (3'-0" FOR 144") VARIABLE 48" DIA. MH RISER PLAN 12" MIN. 48" DIA. MH RISER 48" - 144" PIPE DIAMETER FLOW 48" - 144" PIPE DIAMETER 8'-0" (6'-0" FOR 144") PROFILE SECTION SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER (D.O.T. MH, TYPE 6) TEE MANHOLE SCALE: DATE: 1/4" = 1'-0" JANUARY 2008 PLATE: A9

14 Drawing #: A10 2' X 3' Storm Inlet Box 2'-0" 3'-0" 18" MAX. RCP PIPE 24" MAX. RCP PIPE PLAN 18" - 42" TALL (3" INCREMENTS) PROFILE SPECIFICATIONS * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * STOCK INLET BOXES AVAILABLE IN 24", 30", 36", 42" HEIGHTS WITH ONE 20" HOLE AND TWO PARTIAL HOLES ROUGH CUT * 2'x3'x2" (&4") ADJUSTING SQUARES AVAILABLE * 2'x3' RISERS AVAILABLE (6", 12", 15", 18", 24", 30" HEIGHTS) * 2'x3' RISER = 725LBS/FT, ADD 700LBS FOR MONO BASE

15 Drawing #: A10.1 2' X 3' Storm Catch Basin 3'-0" PLAN 42" MAX. (3" INCREMENTS) AS SPECIFIED 2'-0" PROFILE AS" SPECIFIED ALTERNATE DESIGN OF A CATCH BASIN, TYPE 2 1. ONE PIECE SET - NO REDUCING FLAT TOP TO FIT "H" CASTING - MONO BASE CONSTRUCTION 2. "STANDARD" SIZE STRUCTURE - READILY AVAILABLE 3. SMALLER "FOOTPRINT" TO FIT TIGHT CURB LINE UTILITY AREAS 4. MANUFACTURED TO ASTM C-478 SPECIFICATIONS (D.O.T. INLET, TYPE 3 - MODIFIED) SCALE: 3/4" = 1'-0" PLATE: 2'x3' INLET BOX w/ SUMP DATE: JANUARY 2008 A10.1

16 Drawing #: A11 Median 1 Grate Inlet 5¾" 3'-10" 2'-10½" 5¾" PLAN 8" 4'-0" MAX. 4" 3'-10" 2'-10½" 5¾" 8" WALL 5¾" 8" 2'-6" 8" PROFILE PE 8 SPECIFICATIONS * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * #4 REINFORCING BARS 12"C-C * 1260 LBS./VERTICAL FT., ADD 700 LBS. FOR CAST IN BASE

17 Drawing #: A12 Median 2 Grate Inlet 6'-8" 5¾" 2'-10¼" 2'-10¼" PLAN 8" 6'-0" MAXIMUM 4" 3'-10" 2'-10½" 5¾" 2¼" 8" WALL 8" 5'-4" PROFILE 8" TYPE 9 SPECIFICATIONS * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * #4 REINFORCING BARS 12"C-C * 1840 LBS./VERTICAL FT., ADD 1350 LBS. FOR CAST IN BASE

18 Drawing #: A13 Median 2 Grate Inlet W/ 72" Manhole 2'-6" 5'-4" SPECIFICATIONS * MANUFACTURED TO ASTM C-478 * APPLICATIONS: 1. DEEP STORM SEWER DESIGN 2. CULVERT DIAMETER EXCEEDS PRECAST OPTION IN TYPE 9 STRUCTURE 1'-0" MIN. TYPE 9 INLET RISER 1'-0" HIGH MIN. 86" x 10" REDUCTION COVER W/ OPENING 72" DIA. VARIES PER PLAN CUTOUT VARIES PER RCP 72" DIA. MANHOLE BOTTOM W/ CUTOUTS FOR CULVERT PIPE 94" x 8" PRECAST BASE NLET, TYPE 9 w/ 72" MANHOLE A

19 Drawing #: A13.1 Median 4 Grate Inlet 3'-6" REQUIRES 4-MS GRATES 18" RCP MAXIMUM PIPE SIZE 2'-6" 2'-10½" PLAN 12-0" 11'-4" 3'-9¼" 2¼" 1'-0" 6" 3" 1'-11" PROFILE 6" SPECIFICATIONS * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * #4 REINFORCING BARS 12"C-C * 5830 LBS EACH

20 Drawing #: A14 42" Diameter Storm Catch Basin 52" x 6" COVER W/ 2' x 3' HOLE 42" CATCH BASIN 4½" WALL 42" DIA. 18" RCP MAX SUMP VARIES 60" x 6" BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * ALL REINFORCING DESIGNED FOR 1" MIN. COVER INLET, TYPE 3-ROUND OPTION)

21 Drawing #: A15 36" Diameter Storm Catch Basin 27" HOLE 44" x 6" COVER W/ 27" HOLE 4" WALL 36" 36" CATCH BASIN SUMP VARIES 52" x 6" BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * ALL REINFORCING DESIGNED FOR 1" MIN. COVER (D.O.T. CATCH BASIN, TYPE 2) SCALE: 3/4" = 1'-0" PLATE: 36" DIAMETER CATCH BASIN DATE: JANUARY 2008 A15

22 Drawing #: A16 30" Diameter Storm Catch Basin 38" x 6" COVER w/27" HOLE 3½" WALL 30" DIA. 30" CATCH BASIN SUMP VARIES 44" x 6" BASE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * ALL REINFORCING DESIGNED FOR 1" MIN. COVER

23 Drawing #: A17 Small Storm Catch Basins CAST IRON GRATE FITS IN BELL END 4' 12" C-14 NON-REINFORCED CATCH BASIN CAST IRON GRATE FITS IN BELL END 4" ROUGH CUTOUT 24" CATCH BASIN 38" x 6" BASE SMALL CATCH BASINS SCALE: DATE: 1/2" = 1'-0" JANUARY 2008 PLATE: A17

24 Drawing #: A18 Date: 1011 Concrete Apron Endwalls C D B T E PLAN VIEW OPTIONAL DESIGN SLOPE 1 A T DIAMETER G LONGITUDINAL SECTION END VIEW G DIA. T A DIMENSIONS IN INCHES B C APPROX. SLOPE ¼ ⁷ ⁷ ¼ 3 TO 1 3 TO ½ ½ 3 TO ¾ ½ 73½ 42 2¾ 3 TO ¼ 9½ 10½ 43½ 49½ ½ 73½ ¼ 3 TO 1 3 TO ½ ¾ 73½ 60 3½ 3 TO ¾ 97¾ TO ½ ½ 3 TO TO ½ ¼ 98¼ 90 5½ 2.4 TO TO ¼ ½ 102½ 102 6½ 2 TO TO TO ½ 24½ TO 1 NOTE: 96 ENDWALL IS NOT FLARED CONCRETE APRON ENDWALLS D E G A1

25 Drawing #: A18.1 Date: RC Endwalls

26 Drawing #: A18.2 6" Concrete Endwall 2½" 15" 14" 8" 7" 12½" 13¾" PLAN VIEW 4½" 3¼" 1" 1¾" 47" 14½" 8" 7" ½" 3" 2" 46" PROFILE VIEW

27 Drawing #: A19 Concrete Elliptical Endwalls C D B T E PLAN VIEW OPTIONAL DESIGN SLOPE 1 RISE SPAN A T LONGITUDINAL SECTION END VIEW EQUIV. DIMENSIONS IN INCHES DIA. SPAN RISE A C APPROX. T B SLOPE 2¾ 3¼ 3¾ 4½ 5 5½ 6 6½ 7 7½ 8½ 9½ ¾ 21 25½ D E TO 1 3 TO 1 3 TO TO TO TO TO TO TO ½ TO 1 NOTE: 90" HE ENDWALL IS NOT FLARED

28 Drawing #: A19.1 Date: x 98 RC Endwalls

29 Drawing #: A19.2 Date: x 106 RC Endwalls

30 Drawing #: A19.3 Date: x 113 RC Endwalls

31 Drawing #: A19.4 Date: x 121 RC Endwalls

32 Drawing #: A20 Galvanized Trash Guards ENDWALL BAR ANCHOR SIZE DIAMETER DIAMETER 12" ¾" 5 8" 15" ¾" 5 8" 18" 21" 24" 27" 30" 36" 42" 48" 54" 60" 66" ¾" ¾" ¾" 1" 1" 1" 1" 1" 1¼" 1¼" 1¼" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 5 8" 72" 1¼" 5 8" 84" 1¼" 5 8" H HEIGHT 2½" 3" 4" 4" 4" 5" 5" 5" 6" 6" 6" 7" 7" 7" 8" * 6" SPACING MAX. * HINGED CONNECTOR PLATE w/ ANCHOR ATTACHED AT THREE POINTS TO ENDWALL H

33 Drawing #: A21 Concrete Pipe Fittings Wyes, Tees, & Transitions MAINLINE W/ WYE MAINLINE W/ TEE MAINLINE TRANSITION NOTE: MAINLINE PIPE 8'-0" LENGTHS

34 Drawing #: A22 Concrete Pipe Fittings Pipe Plugs / Caps & Fabricated Bends SPIGOT CAPS & BELL PLUGS FLOW BELL PLUG SPIGOT CAP FABRICATED BENDS 90 TO 180 L1 L2 FLOW * TOTAL LENGTH OF RCP BEND TO BE L1+L2 = 8'-0"

35 Drawing #: A26 6:1 Slope 18" Concrete Endwall PLAN VIEW 3" DIA. GALV. BARS OPTIONAL " DIA. 2'-0" 18" 19½" 2½" 2' TYP. 8'-4" SECTION VIEW 2'-0" END VIEW SPECIFICATIONS: * MANUFACTURED TO ASTM C-76 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * GALVANIZED BARS ARE OPTIONAL PER SPECIFICATIONS

36 Drawing #: A27 6:1 Slope 24" Concrete Endwall PLAN VIEW 3" DIA. GALV. BARS OPTIONAL 2' TYP " 23¾" 26¾" 3" 2'-6" 24" DIA. 11'-0" SECTION VIEW 2'-6" END VIEW SPECIFICATIONS: * MANUFACTURED TO ASTM C-76 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * GALVANIZED BARS ARE OPTIONAL PER SPECIFICATIONS

37 Drawing #: A29 Date: 0713 Precast Concrete Box Culvert Sizes Sheet Size Span x Rise Approx. Equivalent Round Dia. Approx. Water Area/Sq. Ft. Approx. Weight/L. Ft. 4 x x x x x x x x x x x x x x x x x x x x x x x x x x ASTM C1433 Price/Ft. 2:1 Type 1 End Section Precast Dropwall Please Call for Pricing 12 x 3 2 x x 3 2 x x 3 2 x x 3 2 x 19 4 PRECAST BOX NOTES: (*PRODUCT DIMENSIONS & WEIGHTS WILL BE VERIFIED BY SHOW DRAWINGS.) * MAXIMUM LENGTH is 6-0 * TOP SLAB THICKNESS = 9 * SIDE WALL THICKNESS = 8 * BOTTOM SLAB THICKNESS = 10 JOINT TIES (TWO SETS PER JOINT) BUTYL SEALANT (1 1/4 x 14-6 ) - ALL PRICES F.O.B. JOBSITE - DELIVERED TO NEAREST ACCESSIBLE POINT BY TRUCK UNDER ITS OWN POWER IN TRUCKLOAD LOT - LESS THAN FULL LOADS SUBJECT TO A DELIVERY CHARGE - PRICES SUBJECT TO CHANGE WITHOUT NOTICE ASTM C1433- STANDARD SPECIFICATIONS FOR PRECAST REINFORCED CONCRETE MONOLITHIC BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS. ASTM C1577- STANDARD SPECIFICATIONS FOR PRECAST REINFORCED CONCRETE MONOLITHIC BOX SECTIONS FOR CULVERTS, STORM DRAINS, AND SEWERS DESIGNED ACCORDING TO AASHTO LRFD.

38 Drawing #: A30 Precast Concrete Box Culvert End Sections 1½"-2" CLEAR NOTE: TOP OF BOX TO HAVE LIFT HOLES (4) M Tt 2'-6" 1'-0" 1'-0" As2 As5 1'-0" x 1'-0" HAUNCH JOINT TIE HOLE As1 #3 HAUNCH BAR 30" LONG 12" O.C. LAPPED BEYOND INNER MESH 4" AT BOTH ENDS As5 As3 BOTTOM OF BOX As4 H As1 Tb Ts W Ts 2'-0" 1'-0" 12" x 12" CURB 1'-0" 9" 4" LEVEL 2 1 1'-6"(TYP) 6'-6" (h6) (h5) (h4) (h3) (h2) 1'-8" (TYP) 10" (H) DROP WALL (E SEC.) (D SECTION) (C SECTION) (B SECTION) (A SECTION) H (FT.) (L) TYPE 1 END SECTION TYPE 1 END SECTION PROPERTIES L A SECTION B SECTION C SECTION D SECTION (FT.) A Ah ( IN2 h2 B h3 h4 FT ) Ah ( IN2 C FT ) Ah ( IN2 D (FT.) (FT.) (FT.) FT ) (FT.) Ah ( IN2 FT ) h '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" '-8" OX CULVERT END SECTION A3

39 Drawing #: A31 Hydroguard Stormwater Treatment Structure VARIES AS NEEDED STRUCTURE I.D. A INNER CHAMBER OUTLET BAFFLE WALL INLET PIPE INNER CHAMBER INLET INNER CHAMBER OUTLET B C E I H F G J OUTLET PIPE OUTLET CHAMBER D INNER CHAMBER MIDDLE CHAMBER OUTLET CHAMBER HYDROGUARD - SECTION VIEW A A A RIGHT 90 BEND TOP VIEW RIGHT < 45 BEND STRUCTURE I.D. 48" 72" 96" 120" 144" A - I.D. 30" 48" 60" 78" 96" B 36" 48" 48" 60" 48" C 60" 72" 84" 84" 84" D 30" 30" 30" 30" 30" E 6" 12" 16" 20" 24" F 36" 39" 43" 47" 48" G 12" 18" 22" 26" 36" H I 12" 5" 15" 8" 15" 11" 18" 14" 18" 16" J 15" 24" 30" 36" 48" PERMANENT POOL VOLUME 450 US GALLONS 1200 US GALLONS 2400 US GALLONS 4300 US GALLONS 7000 US GALLONS NOTES: STRUCTURE EFFICIENTLY REMOVES SUSPENDED SOLIDS (AND ASSOCIATED METALS, NUTRIENTS AND BACTERIA), OIL, AND TRASH FROM STORMWATER RUNOFF FULFILLING THE REQUIREMENTS OF MOST NPDES PERMITS AND CLEAN WATER ACT REQUIREMENTS. TECHNICAL INFORMATION AND SIZING AVAILABLE ON REQUEST. MEETS OR EXCEEDS THE REQUIREMENTS OF ASTM C-76 AND ASTM C-478.

40 Drawing #: B1 Sanitary Sewer Systems Sanitary Manhole Sizing Chart MANHOLE DIAMETER MAXIMUM PIPE SIZE FOR PRECAST STRUCTURES STRAIGHT RIGHT ANGLE 15" RCP 48" 18" RCP 24" PVC 18" PVC 18" RCP 60" 24" RCP 30" DI 24" PVC 24" RCP 72" 30" RCP 36" DI 30" DI SANITARY MANHOLE SIZING CHART WITH FLEXIBLE WATERTIGHT CONNECTIONS SCALE: DATE: 1/8" = 1'-0" JANUARY 2008 PLATE: B1

41 Drawing #: B2 Sanitary Sewer Systems Standard Sanitary Manhole SLOPE BENCH FLOW PER PLAN NOTE: PLAN VIEW SHOWN WITH OPTIONAL FLOWLINES PLAN VIEW 27" DIA. 3'-0" PRECAST CONE 5" WALL 48" DIA. STOCK RISERS 1'-0",1'-4",2'-0" 2'-4",2'-8",4'-0" 5'-4" 2'-2" MIN. W/ 2'-8" BOTTOM 3'-6" MIN. W/ 4'-0" BOTTOM FLOW LINE 6" 66" SECTION VIEW * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH ASTM C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" C-C SPECIFICATIONS: STANDARD SANITARY MANHOLE * EXTENDED MONOLITHIC BASE SECTION BUILT PER PLAN DIMENSIONS AND SPECIFICATIONS BY SPECIAL ORDER * PIPE TO MANHOLE BOOT SEAL ACCOMODATES 2" THROUGH 18" PIPE, CALL FOR SPECIAL LARGER PIPE SIZING * FLOWLINES AVAILABLE UPON REQUEST * 48" DIAMETER LBS./VERTICAL FT. SCALE: 3/8" = 1'-0" DATE: JANUARY 2008 PLATE: B2

42 Drawing #: B3 Sanitary Sewer Systems Shallow Sanitary Manhole SLOPE BENCH FLOW PER PLAN NOTE: PLAN VIEW SHOWN WITH OPTIONAL FLOWLINES PLAN VIEW 4" FRAME W/ COVER ADJUSTING RINGS 12" 58" x 8" KEYED FLAT TOP 5" WALL 48" DIA. 2'-2" MIN. FLOWLINE 66" SECTION VIEW 6" 48" x 2'-8" BOTTOM W/ MONOLITHIC BASE SECTION SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * EXTENDED MONOLITHIC BASE SECTION BUILT PER PLAN DIMENSIONS AND SPECIFICATIONS BY SPECIAL ORDER * PIPE TO MANHOLE BOOT SEAL ACCOMODATES 2" THRU 18" PIPE CALL FOR SPECIAL OR LARGER PIPE SIZING * FLOWLINES AVAILABLE UPON REQUEST * 48" DIAMETER LBS./VERTICAL FT. SHALLOW SANITARY MANHOLE SCALE: DATE: 3/8" = 1'-0" JANUARY 2008 PLATE: B3

43 Drawing #: B4 Sanitary Sewer Systems Sanitary Reduction Manhole 27" DIA. STOCK RISERS 1'-0", 1'-4", 2'-0" 3'-0" PRECAST CONE 2'-4", 2'-8", 4'-0" 5'-4" 48" DIA. VARIES 60", 72", 84", 96", 108", 120", 144" DIAMETER 4'-0", 6'-0", 8'-0" TYP. 4" MIN. 8" MIN. PER PLAN SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER * EXTENDED MONOLITHIC BASE SECTION BUILT PER PLAN DIMENSIONS AND SPECIFICATIONS BY SPECIAL ORDER * SANITARY SEWERS TO HAVE PIPE TO MANHOLE SEALS MANUFACTURED TO ASTM C-923 * EZ-STIK JOINT SEALANT CONFORMING TO ASTM C-443 * SEE DETAIL FOR REDUCTION COVER DATA * SEE SANITARY MANHOLE SIZING CHART FOR MAXIMUM ALLOWABLE PIPE SIZE PER MANHOLE DIAMETER SANITARY REDUCTION MANHOLE SCALE: DATE: 3/8" = 1'-0" JANUARY 2008 PLATE: B4

44 Drawing #: B5 Sanitary Sewer Systems Reduction Cover VARIES 48" DIA. 10" THICK FOR 60",72" 12" THICK FOR 84",96" 14" THICK FOR 108", 120", 144" 60", 72", 84", 96", 108" 120", 144" DIAMETER MANHOLE SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" ON CENTER

45 Drawing #: B9 Sanitary Sewer Systems Combined Lift Station (72 ) 10" 4" 6" VARIES (SECTION: 5'-0" MAX) 3'-0" 5'-8" 11" 16" 72" DIAMETER VARIES (SECTION: 8'-0" MAX) 7" PROFILE VIEW 4" * MANUFACTURED TO ASTM C-478 & C-858 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH ASTM C-478 & C-858 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" C-C SPECIFICATIONS: COMBINED LIFT STATION 12" * HATCHES, PUMPS, PIPING BY OTHERS * PIPE TO MANHOLE BOOT SEAL ACCOMMODATES 2" THROUGH 18" PIPE, CALL FOR SPECIAL LARGER PIPE SIZING * VALVE CHAMBER LBS./VERTICAL FT. * 72" DIAMETER LBS./VERTICAL FT. SCALE: 1/4" = 1'-0" DATE: JANUARY 2008 PLATE: B9

46 Drawing #: B10 Sanitary Sewer Systems Combined Lift Station (72 Cont.) 6'-0" x 10'-0" x 10" KEYED COVER W/ HATCHES 4" 6" 6'-0" (RISER O.D.) 5'-0" VARIES 7'-2" (TRANS. SLAB O.D.) 3'-0" 5'-8" 10'-0" SECTION A VIEW * MANUFACTURED TO ASTM C-478 & C-858 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH ASTM C-478 & C-858 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" C-C SPECIFICATIONS: * HATCHES, PUMPS, PIPING BY OTHERS * PIPE TO MANHOLE BOOT SEAL ACCOMMODATES 2" THROUGH 18" PIPE, CALL FOR SPECIAL LARGER PIPE SIZING * VALVE CHAMBER LBS./VERTICAL FT. * 72" DIAMETER LBS./VERTICAL FT. COMBINED LIFT STATION SCALE: DATE: 1/4" = 1'-0" JANUARY 2008 PLATE: B10

47 Drawing #: B11 Sanitary Sewer Systems Combined Lift Station (96") 10" 4" 6" VARIES (SECTION: 5'-0" MAX) 4'-0" 6'-8" 11" 16" 96" DIAMETER VARIES (SECTION: 8'-0" MAX) 9" PROFILE VIEW 4" * MANUFACTURED TO ASTM C-478 & C-858 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH ASTM C-478 & C-858 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" C-C SPECIFICATIONS: COMBINED LIFT STATION (96") 12" * HATCHES, PUMPS, PIPING BY OTHERS * PIPE TO MANHOLE BOOT SEAL ACCOMMODATES 2" THROUGH 18" PIPE, CALL FOR SPECIAL LARGER PIPE SIZING * VALVE CHAMBER LBS./VERTICAL FT. * 96" DIAMETER LBS./VERTICAL FT. SCALE: 1/4" = 1'-0" DATE: JANUARY 2008 PLATE: B11

48 Drawing #: B12 Sanitary Sewer Systems Combined Lift Station (96" Cont.) 7'-6" x 12'-0" x 10" KEYED COVER W/ HATCHES 4" 6" 7'-6" (RISER O.D.) 6'-6" VARIES VARIES 10'-0" (TRANS. SLAB O.D.) 4'-0" 6'-8" 12'-0" SECTION A VIEW * MANUFACTURED TO ASTM C-478 & C-858 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH ASTM C-478 & C-858 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER * STEP - STEEL, PLASTIC COATED, 16" C-C SPECIFICATIONS: COMBINED LIFT STATION (96") * HATCHES, PUMPS, PIPING BY OTHERS * PIPE TO MANHOLE BOOT SEAL ACCOMMODATES 2" THROUGH 18" PIPE, CALL FOR SPECIAL LARGER PIPE SIZING * VALVE CHAMBER LBS./VERTICAL FT. * 96" DIAMETER LBS./VERTICAL FT. SCALE: 1/4" = 1'-0" DATE: JANUARY 2008 PLATE: B12

49 Drawing #: B13 Sanitary Sewer Systems Sanitary Drop Manhole Pieces 4' DROP COLLAR DROP PAD 4" 26" 20" 22" 17" 24" PLAN VIEW 3½" 6" 36" PLAN VIEW PROFILE VIEW 6" DROP COLLAR 50" TALL 21½" 18" 3½" PROFILE VIEW 15½" PLAN VIEW 3" 6" PROFILE VIEW SPECIFICATIONS: * MANUFACTURED TO ASTM C-478 SPECIFICATIONS * CONCRETE STRENGTH P.S.I. * STEEL DESIGN IN ACCORDANCE WITH A.S.T.M. C-478 * ALL REINFORCING DESIGNED FOR 1" MIN. COVER DROP MANHOLE PIECES SCALE: DATE: 1/2" = 1'-0" JANUARY 2008 PLATE: B13

CONCRETE MANHOLES.

CONCRETE MANHOLES. CONCRETE CONCRETE SHAW PIPE produces circular, precast, concrete manholes in diameters 1050mmØ through 3000mmØ. Precast, concrete manholes are most frequently used for pipeline and sewer entry and are

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles

Utility Structures. Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles Utility Structures Utility vaults, trenches, transformer pads Electrical Pole Bases and switching cubicles PRODUCT GUIDE & TECHNICAL REFERENCE MANUAL Providing the right solutions. UTILITY STRUCTURES Perfect

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

Standard Specifications

Standard Specifications Standard Specifications PART 1.00 GENERAL 1.01 DECRIPTION SECTION 02620 PRECAST REINFORCED CONCRETE SANITARY MANHOLES A. Work included: The Contractor shall furnish all labor, materials, equipment, and

More information

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing

ABOUT INLAND. Tannis Karklin, E.I.T Technical Sales and Marketing ABOUT INLAND Inland roots in the Winnipeg area date back to the early 960 s. Over time, through a number of mergers and acquisitions Inland Pipe is now part of the Lehigh Hanson group in North America

More information

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends)

SUBJECT: Standard Plate Turf Establishment Areas (at Pipe Culvert Ends) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-01) MANUAL: Standard

More information

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info

SUBJECT: Standard Plates 4132, 4155, Drainage Structures and Castings Info MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (18-01) MANUAL: Standard

More information

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details.

Standard Plate 7036 is discontinued. It is replaced by Standard Plan Pedestrian Curb Ramp Details. DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-02) MANUAL: Standard Plates DATED: May 11, 2012 SUBJECT: Standard

More information

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes MANHOLES PART I: GENERAL A. Precast Concrete Manholes 1) Manholes shall be made of precast concrete sections of which the top section shall be eccentric or flat slab top. The bottom section shall be a

More information

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual.

INSTRUCTIONS: 1. Record the transmittal letter number, date, and subject on the transmittal record sheet located in the front of the manual. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Technical Support Design Services Section TRANSMITTAL LETTER NO. (0-03) MANUAL: Standard Plates DATED: September

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (15-03) MANUAL: Standard

More information

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION ONTARIO PROVINCIAL STANDARD SPECIFICATION METRIC OPSS 407 NOVEMBER 2013 CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION TABLE OF CONTENTS 407.01

More information

Current Standard Plates including Transmittal Letters are available on the web at:

Current Standard Plates including Transmittal Letters are available on the web at: MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-04) MANUAL: Standard

More information

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings

Engineering and Construction Services Division Construction Drawings for Sewers and Watermains. T No. Revision T No. Revision Remarks All T drawings Engineering and Construction Services Division Construction Drawings for Sewers and Watermains Revision No. 8 April All T drawings New title block for each drawing is now standardized. Revision numbers

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 02601 MANHOLES PART 1 GENERAL 1.01 SCOPE OF WORK A. WORK required under this section consists of all materials, accessories, equipment, tools, and labor required to install precast concrete standard

More information

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN

STANDARD CATCH BASIN GUTTER LINE CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D CONCRETE CURB FINISHED GRADE ASPHALT MAX 50 MIN CB INLET FRAME & GRATE, GROUTED TO GRADE RINGS AS REQ'D ASPHALT 20 GUTTER LINE CONCRETE CURB FINISHED GRADE PRECAST GRADE RINGS, 2 50 100 MAX PRECAST CB LID GROUT ALL AROUND CB LEAD, INSIDE & OUTSIDE OF

More information

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends

SUBJECT: Standard Plate 9102 Turf Establishment Areas At Pipe Culvert Ends MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Project Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (17-03) MANUAL: Standard

More information

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION 39 - MANHOLES TABLE OF CONTENTS SECTION 39 - MANHOLES TABLE OF CONTENTS Section Page 39-1 GENERAL... 39.1 39-2 PRECAST CONCRETE MANHOLES... 39.1 39-2.01 Precast Concrete Sewer Manholes... 39.1 39-2.02 Precast Concrete Storm Drain Manholes...

More information

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO.

RECORD DRAWINGS REVISED TO CONFORM TO CONSTRUCTION RECORDS PROVIDED BY CONTRACTOR GMG BY DATE 11/13 CRS NO. CELL: (715) 803-8009 MABOSI@WISCONSINPUBLICSERVICE.COM CELL: (715) 573-7806 CHVIRCKS@WISCONSINPUBLICSERVICE.COM CALVIN.KLADE@FTR.COM DGAU@KRONENWETTER.COM SCOTT OLSEN (715) 302-1348 S REVISED TO CONFORM

More information

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY

MSD STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY MSD M etr o p olitan S e w e r Di s t r ict STANDARD DRAWINGS LOUISVILLE AND JEFFERSON COUNTY METROPOLITAN SEWER DISTRICT 700 WEST LIBERTY STREET LOUISVILLE, KENTUCKY 40203-1911 STANDARD DRAWINGS DIVISION

More information

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

STORM M ANHOLE FOR 42 PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30MAX 3 OR 3.5 PRECAST ECCENTIC CONC 01-APR-2015 13:33 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\stm_det01_8x11_st01.dgn TIME = MIN 3 CRSES MAX 5 CRSES 3 OR 3.5 PRECAST ECCENTIC CONC ID PIPE GRADE A CONC FILL 4" 8" 2-0"SUMP

More information

STANDARD BID ITEM NUMBERS

STANDARD BID ITEM NUMBERS 10701 TRAFFIC CONTROL LUMP SUM 10702 Traffic Control for Storm Sewer Installation LUMP SUM 10703 Traffic Control for Water Main Installation LUMP SUM 10704 Traffic Control for Sanitary Sewer Installation

More information

Design Data 12M. Hydraulic Capacity of Precast Concrete Boxes. RISE, Millimeters. Span Millimeters

Design Data 12M. Hydraulic Capacity of Precast Concrete Boxes. RISE, Millimeters. Span Millimeters Design Data 12M Hydraulic Capacity of Precast Concrete Boxes Under certain conditions the hydraulic or structural characteristics of reinforced concrete box sections offer advantages over the circular

More information

Anti-Trust Statement

Anti-Trust Statement Anti-Trust Statement http://www.concrete-pipe.org/ A joint effort of the Texas Concrete Pipe Association and the Texas Department of Transportation What brought this about? The TxDOT organization consists

More information

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public

MH Table of Contents Standard Title/Scope Page Table of Contents SCE Public MH Table of Contents Standard Title/Scope MH 300 MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Manholes Requirements MH 300.1 Manholes Requirements...........................................

More information

Manholes Table of Contents

Manholes Table of Contents Standard MH 300 Title Manholes Requirements MH 300.1 Manholes Requirements Manholes Table of Contents Underground Structures Standards MH 310 MH 318 MH 320 MH 325 MH 330 MH 335 MH 340 MH 350 Precast Tub-Type

More information

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX

MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1 - MAINTENANCE HOLES, CATCH BASINS AND DITCH INLETS - MTC FORM 407 INDEX 407-1.1 GENERAL Tender Items Specifications Standard Drawings 407-1.1.1 Frame and Grate Selection 407-1.1.2 Selection of Structure

More information

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1

UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 UTILITY AND STREET CONSTRUCTION PLAN REQUIREMENTS SECTION 1 ENGINEERING STANDARDS FOR UTILITY AND STREET CONSTRUCTION PLANS MARCH 2014 CONSTRUCTION PLAN SHEET FORMAT REQUIREMENTS REPRODUCIBLE MYLAR 1.

More information

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office.

Standard Plate Sheer Reinforcement for Precast Drainage Structures has been updated upon recommendation of the Bridge Office. MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (13-03) MANUAL: Standard

More information

C-M TMR Products Index

C-M TMR Products Index C-M TMR Products Index TMR Dwg. No. Grate/Frames 9x6 Dwg. AS3996 Recessed Road Gully Units Dwg. 1443, 1444 Protruded Road Gully Units Dwg. 1443, 1444 1220 Road Gully Units Dwg. 1459 7x4 Road Gully Units

More information

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD.

VILLAGE OF VILLA PARK CENTRAL BOULEVARD IMPROVEMENTS LOCATION MAP (NOT TO SCALE) CORTESI AVE. MYRTLE AVE. CENTRAL BLVD. Q:\VillaPark_IL\11283000 Astor-Myrtle Sewer Separation Preliminary Design\D.4 CAD\Sheets\North\1. Cover.dwg INDEX OF SHEETS 1 COVER 2 GENERAL NOTES 3 SUMMARY OF QUANTITIES 4 ALIGNMENT 5-9 DRAINAGE AND

More information

STORM SEWER SCHEDULE STRUCTURES ALIGNMENT CODES: 'CW'= COMANCHE WAY PIPES BURNING WOOD, COMANCHE, 4TH SHEET NO. UTIL W RESURF ASSESSMENT DISTRICT-2015 U-3 PROJECT NO. 53W1930 COMANCHE WAY STORM SEWER SCHEDULE

More information

SECTION G ESTIMATE OF QUANTITIES

SECTION G ESTIMATE OF QUANTITIES PROJECT STATE OF SOUTH DAKOTA NH 2115(45)87 SHEET G2 TOTAL SHEETS G27 SECTION G ESTIMATE OF QUANTITIES BID ITEM NUMBER ITEM QUANTITY UNIT 009E0010 Mobilization Lump Sum LS 560E0068 7'x3' Precast Concrete

More information

SECTION MANHOLES

SECTION MANHOLES SECTION 33 05 13 MANHOLES PART 1 GENERAL 1.01 SECTION INCLUDES A. CONTRACTOR shall furnish and install precast concrete manhole base, sections, adjusting rings, steps, and manhole ring and cover, complete.

More information

STRUCTURES FOR SANITARY AND STORM SEWERS

STRUCTURES FOR SANITARY AND STORM SEWERS SUDAS Standard Specifications Division 6 - Structures for Sanitary and Storm Sewers Section 600 - Structures for Sanitary and Storm Sewers STRUCTURES FOR SANITARY AND STORM SEWERS PART - GENERAL.0 SECTION

More information

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES SECTION 02545 PRECAST CONCRETE SECTIONAL MANHOLES PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Precast reinforced concrete cylindrical sectional manholes, complete with openings, inserts, hardware,

More information

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA

DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA DESIGN GUIDELINES (SD) COUNTY OF ALAMEDA PUBLIC WORKS AGENCY 399 ELMHURST STREET HAYWARD, CA 94544-1395 PUBLIC WORKS DESIGN GUIDELINES TABLE OF CONTENTS SD-100 SERIES SPECIAL DRAWINGS SD-100 8/1991 SILT

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted

More information

CITY OF MUSKEGO DRAFTING STANDARDS

CITY OF MUSKEGO DRAFTING STANDARDS CITY OF MUSKEGO DRAFTING STANDARDS GENERAL - These standards apply to all plans. 1. Plans must be prepared on sheets measuring 36 inch across and 22 inch to 24 inch high unless otherwise specified under

More information

24" Dia. 36" Dia. WE BUILD CONFIDENCE

24 Dia. 36 Dia. WE BUILD CONFIDENCE WE BUILD CONFIDENCE WE BUILD CONFIDENCE PRECAST STRUCTURES SERVE AS KEY COMPONENTS OF OUR UTILITY AND TRANSPORTATION INFRASTRUCTURE. AND MAKING THE INDUSTRY S BEST PRECAST PRODUCTS TAKES DEDICATION, ATTENTION

More information

DISTRIBUTION VAULT 8' x 14' x 9'-4" DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING

DISTRIBUTION VAULT 8' x 14' x 9'-4 DEEP TRAFFIC FLAT WALL WITH 5' x 8' OPENING CU16003K REV 8' x 14' x 9'4" DEEP TRAFFIC FLAT WALL 0113 SHEET 1 OF 6 CU 16003K CU16003K REV 8' x 14' x 9'4" DEEP TRAFFIC FLAT WALL 0113 SHEET OF 6 CU 16003K ITEM (PER ENDWALL): A. 6" DIAMETER PVC CONDUIT

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

General Information. Ball Curb Valve

General Information. Ball Curb Valve General Information 1. All Jones Curb Valves are manufactured in accordance with the AWWA Standard C-800-latest revision. 1. Copper Alloy CDA No. C83600 (85-5-5-5) 2. Copper Alloy CDA No. 89520 (Low Lead)

More information

PRODUCT CATALOGUE. Saskatchewan

PRODUCT CATALOGUE. Saskatchewan PRODUCT CATALOGUE Saskatchewan From Cover Victoria Avenue (TransCanada Hwy ) is the primary entrance into the east side of Regina, SK and has over 40,000 vehicles per day travelling on it. The existing

More information

"A" "A" SECTION "A-A" X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department

A A SECTION A-A X-SECTION VERTICAL CURB (TYPE B) Village STREET & PAVEMENT STR-05. Engineering Department 1" 1/2" PRE-MOLDED NON-EXTRUDING JOINT FILLLER AT EXPANSION JOINTS (MAXIMUM 50' SPACING) 2" R "A" SEE NOTE 3 0.5" 1/8" R (TYP) DEPRESSED 1.5" PAVEMENT THICKNESS 3.5" 5.0" "A" 2" MINIMUM STONE CUSHION GRADATION

More information

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST

NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST NEWTON COUNTY WATER AND SEWERAGE AUTHORITY RESIDENTIAL, COMMERCIAL, INSTITUTIONAL AND INDUSTRIAL SUBDIVISIONS CONSTRUCTION PLANS CHECK LIST Project Name Checked By Date Designer Check List marks to be

More information

City of Regina Standard Construction Specifications SECTION LIST OF SEWER STANDARD DRAWINGS

City of Regina Standard Construction Specifications SECTION LIST OF SEWER STANDARD DRAWINGS City of Regina Standard Construction Specifications SECTION 14999 LIST OF SEWER STANDARD DRAWINGS S-1 No Drawing Feb/10 S-2 Precast Manhole 1050mm Dia. July/10 S-2B Precast Manhole 1200mm Dia. Jan/17 S-3

More information

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings

SECTION 095 SPECIFICATIONS DETAIL DRAWINGS. Index of Detail Drawings SECTION 095 SPECIFICATIONS DETAIL DRAWINGS Index of Detail Drawings Flat Top Manhole... 095-1 Splash Drop Manhole and Regular Drop Manhole... 095-2 Special Detail Splash Drop Manhole and Special Detail

More information

The Most Advanced Name in Drainage Systems. Water Management Product Catalog

The Most Advanced Name in Drainage Systems. Water Management Product Catalog The Most Advanced Name in Drainage Systems Water Management Product Catalog Foreword This manual has been prepared to assist in identifying ADS products and product numbers. It is intended to be a fast

More information

CS3 represents manufacturers of products for use in the municipal waterworks industry.

CS3 represents manufacturers of products for use in the municipal waterworks industry. Brian Drexel & Rob Grier WWW.CS3WATERWORKS.COM Established in 2000, CS3 Waterworks is a Florida Based company with offices in Orange Springs Florida and Savannah Georgia. CS3 represents manufacturers of

More information

CITY OF VISTA STANDARD DRAWINGS

CITY OF VISTA STANDARD DRAWINGS CITY OF VISTA STANDARD DRAWINGS May, 2015 THIS SHEET INTENTIONALLY LEFT BLANK TABLE OF CONTENTS MODIFICATIONS Modifications to San Diego Regional Standard Drawings DRAINAGE STRUCTURES DRN 01 Corrugated

More information

Grease Interceptor Design Checklist

Grease Interceptor Design Checklist CHECKLIST C2 Revised 5/2/2016 Grease Interceptor Design Checklist Public Works DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private

More information

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS 1. DESCRIPTION THESE SPECIFICATIONS ARE FOR A PRECAST THREE SIDED ARCH STRUCTURE, HEADWALLS

More information

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL

INSTALLATION INSTRUCTIONS. March 2016 FOR FURTHER QUESTIONS, PLEASE CALL March 2016 INSTALLATION INSTRUCTIONS FOR FURTHER QUESTIONS, PLEASE CALL 775 440 2025 JENSEN WATER RESOURCES 521 Dunn Circle, Sparks, NV 89431 JensenPumps.com Figure 1: This illustration shows a complete

More information

Oil-Water Separator Design Checklist

Oil-Water Separator Design Checklist CHECKLIST C3 Revised 5/2/2016 Oil-Water Separator Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling private oil-water

More information

CITY OF VISTA STANDARD DRAWINGS

CITY OF VISTA STANDARD DRAWINGS CITY OF VISTA STANDARD DRAWINGS May, 2015 THIS SHEET INTENTIONALLY LEFT BLANK TABLE OF CONTENTS MODIFICATIONS Modifications to San Diego Regional Standard Drawings DRAINAGE STRUCTURES DRN 01 Corrugated

More information

Thermoplastic Valves Sewer Disconnect

Thermoplastic Valves Sewer Disconnect Sewer onnect Spears Sewer onnect functions as both cleanout and disconnect device, plus helps prevent sewage backup during hurricanes and floods. Complete unit consists of body and plunger (sold separately

More information

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS

SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS 9. STANDARD DETAILS SECTION III STANDARD DRAWINGS ROYSE CITY GENERAL CONSTRUCTION NOTES & DETAILS j:\clerical\royse city\1-4086 general services\168-tech const standards review\tcss manual\2018 tcss manual\sec-9a

More information

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C

MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C MEDIUM DUTY CAST IRON SLIDE GATES SERIES 20-10C Revised October 2007 Armtec reserves the right to alter designs. General The Armtec Sluice Gate is a quality and highly economical gate for a variety of

More information

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION Sheet 1 of 5 KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION NOTE: This special provision is generally written in the imperative mood. The subject, "the

More information

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials.

SECTION PUBLIC UTILITY MANHOLES AND STRUCTURES. 2. Modular precast concrete pump wetwell. 5. Manhole bedding and cover materials. SECTION 02082 PUBLIC UTILITY MANHOLES AND STRUCTURES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Modular precast concrete manholes with tongue-and-groove joints, transition to cover frame, covers,

More information

MUNICIPAL INFRASTRUCTURE

MUNICIPAL INFRASTRUCTURE 2440 MUNICIPAL INFRASTRUCTURE 100 50 90 90 1220 305 65 65 45 MUNICIPALITY OR SERVICE OARD Department of Municipal Affairs and Environment Hon., Minister 40 100 50 50 WHITE REFLECTIVE ACKGROUND 1. LETTERING

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility B 64" 1626 602'-8 1/16" 183695 548'-0" 167030 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 373839 40 25 IMPACT 1500A 48" 12 27'-5" 8355 [] 3x7 CL A Galvanized

More information

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION

PART 4 STANDARD DRAWINGS FOR CONSTRUCTION 4.0. INTRODUCTION PART 4 STANDARD DRAWINGS FOR CONSTRUCTION In this document, Ivins City adopts the most recent edition (currently 2007), including all amendments, of the APWA Utah Chapter s Manual of

More information

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS

UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed 6/1/18 STANDARD DRAWINGS Date 6/1/18 STANDARD DRAWINGS UPDATE LOG FOR STANDARD DRAWINGS Item(s) Changed WATER STANDARD DRAWINGS Title Drawing Number Current Date Fire Hydrant and Appurtenance Locations, Improved Streets with Curb

More information

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 StormTrap Guide Specification StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18 This product guide specification is written according to the Construction Specifications Institute

More information

GENERAL ISOMETRIC LAYOUT

GENERAL ISOMETRIC LAYOUT EXISTING OR PROPOSED WIPER WALL SUPPORT STRUCTURE GATE LID CARBATHAN HG 0 WEB GRAY LOWER PAN GRATING ALUMINUM WIPER WALL CARBATHANE HG, 90 GRAY STRUCTURAL SPECIFICATIONS:. FLOODGATE MATERIAL TO BE ALUMINUM

More information

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST.

Plate 8132A - Preformed Rigid PVC Conduit Loop Detector, is a new plate requested by OTST. DISTRIBUTION: 7 MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Design Services Section TRANSMITTAL LETTER NO. (0-0) MANUAL: Standard Plates DATED: January 9, 00 SUBJECT:

More information

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows.

A. Radius elbows with a construction radius of 1.5 the duct width are preferred to square elbows. SECTION 233100 DUCTWORK 1.0 Acoustical duct lining in any part of the duct system is prohibited. All ductwork requiring insulation shall be externally insulated (Refer to the Sheet Metal Ductwork Insulation

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS

SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS 8.01 - Page i UDNP Standard Specifications SECTION 8: DRAINAGE, SEWER AND WATER SUPPLY NETWORKS Table of Contents SECTION

More information

STRATUS SHELTER. Take bike parking to new heights

STRATUS SHELTER. Take bike parking to new heights Take bike parking to new heights The Stratus Shelter is a striking bike shelter option for any transit station, university campus, or multi-family residential building project. It is constructed of American

More information

11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014

11-1/4 OD at Transition Point. Microcosmic. 4th and Brannan Street Platform Station Project. Elevation. Moto Ohtake 2014 74 480 330 90 72 180 150 60 90 18 11- OD at Transition Point 36 184 74 Microcosmic Elevation 14 1 Moto Ohtake I. GENERAL NOTES: A. SCULPTURE DESIGN CRITERIA 1. CALIFORNIA BUILDING CODE (CBC, 2010 EDITION)

More information

DIVISION APPROVED MATERIAL LIST AND STANDARD DETAILS

DIVISION APPROVED MATERIAL LIST AND STANDARD DETAILS DIVISION 400 - APPROVED MATERIAL LIST AND STANDARD DETAILS Section 403 - STANDARD DETAILS TABLE OF CONTENTS DIVISION 400, Section 403 - STANDARD DETAILS SECTION DETAIL NOS. Application Table 403-1 I. Concrete

More information

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached).

ACSA PLAN REVIEW CHECKLIST (Guideline Only) (4) Standard water and sewer general plan notes (attached). ACSA PLAN REVIEW CHECKLIST (Guideline Only) Revised: December 3, 2015 General (1) Proper Title (2) Vicinity map on first sheet. (3) Date and latest plan revision. (4) Standard water and sewer general plan

More information

1.1 GENERAL RECORD DRAWING REQUIREMENTS

1.1 GENERAL RECORD DRAWING REQUIREMENTS Page 1 of 5 VILLAGE OF ROMEOVILLE RECORD DRAWINGS CHECKLIST PART I GENERAL Record drawings are required to provide a means of schematic verification that the intent of the approved engineering design has

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility 19'-11 1/2" 6083 239'-11 1/2" 73139 Impact 1100C 25 43 5/16" 1100 upstream from the upstream face of the first shear fender downstream of the joint between barrier nos. 7 and 8 Upstream End Downstream

More information

Miscellaneous. Demolition

Miscellaneous. Demolition Public Improvements Miscellaneous 1 Mobilization L.S. ** 2 Clearing and Grubbing L.S. *** 3 Structural Concrete Incl. Reinforcing C.Y. $1,325.00 4 6" PVC Sleeves L.F. $26.00 Demolition 5 Remove Asphalt

More information

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER

FOR SERVICE BOXES IN CONCRETE DRIVEWAYS, SEE NOTE Min. COVER UNDER DITCHES. 600 Min. COVER WOOD SERVICE MARKER STAKE (50 x 00) PAINTED BLUE PL mm FROM PROPERTY LINE STANDARD CONCRETE SERVICE BOX WITH EXTENSION AS REQ'D 00 FINISHED GROUND/ROAD SURFACE FOR SERVICE BOXES IN CONCRETE DRIVEWAYS,

More information

Sewer Line Extension Permit Design Checklist

Sewer Line Extension Permit Design Checklist CHECKLIST C1 Revised 4/7/2017 Sewer Line Extension Permit Design Checklist DISCLAIMER - This checklist is provided to Consulting Engineers for the express purpose of assisting them in compiling sewer line

More information

HUSSEY GAY BELL SAVANNAH, GEORGIA

HUSSEY GAY BELL SAVANNAH, GEORGIA HUSSEY GAY BELL SAVANNAH, GEORGIA ------------------------------------------------------------------------------------------------------------ ADDENDUM NO. 3 TO THE CONTRACT DOCUMENTS AND TECHNICAL SPECIFICATIONS

More information

ROUND STEEL POLE STRAIGHT

ROUND STEEL POLE STRAIGHT PROJECT NAME: CATALOG NUMBER: NOTES: FIXTURE SCHEDULE: Page: 1 of 7 ROUND STEEL POLE SPECIFICATIONS: Pole Shaft The pole shaft is fabricated from hot rolled steel tubing of onepiece construction with a

More information

FACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES

FACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES KISTNER CONCRETE PRODUCTS, INC. 8713 READ ROAD EAST PEMBROKE, NEW YORK 14056-0218 PH: 585-762-8216 FX: 585-762-8315 FACTS YOU NEED TO KNOW ABOUT WATERTIGHT PRECAST MANHOLES ASTM C-478 ASTM C-443 KISTNER

More information

Created from more than 25 years of experience.

Created from more than 25 years of experience. Created from more than 25 years of experience. The OneLift by Oldcastle Precast, provides a standard turnkey submersible pump station product with the distinction of having a sole-source point of responsibility.

More information

Water Rocket Launcher

Water Rocket Launcher Rocket Activity Water Rocket Launcher Objective Construct a launch platform for launching water rockets. National Science Content Standards Physical Science Position and motion of objects Motions and forces

More information

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS

City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS City of Regina Standard Construction Specification SECTION 2999 LISTING OF ROADWAY STANDARD DRAWINGS R-1 Alternate Pavement Structures July/10 R-2 Typical Cross Sections for Asphaltic Concrete Pavements

More information

civil product range JUNCTION BOXES DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS

civil product range JUNCTION BOXES DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS kilform civil product range ESB CCTV Eircom Services Lighting Risers DUCT CHANNELS AND COVERS Gas Line Cover Slabs ESB Railways ROAD GULLY AND LIDS Untrapped Gully Trapped Gully Large Trapped Gully Headwalls

More information

18" 1.5" 3"R 11.5" 10" 3-1/2" MINIMUM STONE CUSHION GRADATION CA-6

18 1.5 3R 11.5 10 3-1/2 MINIMUM STONE CUSHION GRADATION CA-6 18" 1.5" 3"R 1.5" 4"R 1" 11.5" 10" 13.5" 5" 3-1/2" MINIMUM STONE CUSHION GRADATION CA-6 NOTES: 1. REINFORCEMENT: PROVIDE TWO (2) #4 REINFORCING BARS CONTINUOUS BETWEEN EXPANSION JOINTS, WITH LOCATION SPACING

More information

Series 80 In-Line Mounted Centrifugal Pumps

Series 80 In-Line Mounted Centrifugal Pumps Bulletin B-G Bell & Gossett Series In-Line Mounted Centrifugal Pumps Applications Hydronic Heating & Cooling Systems Industrial Process General Service Pressure Boosting Advantages Close Coupled Space

More information

Product Guide Specification

Product Guide Specification Zurn Industries, LLC November 2014 1801 Pittsburgh Avenue Erie, PA 16502 Toll Free (855) 663-9876 Phone (814) 455-0921 Fax (814) 871-6141 Website www.zurn.com Product Guide Specification Specifier Notes:

More information

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO. 2012-16A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST 2014 CHAIN LINK FENCE SPECIFICATIONS Chain link fence,

More information

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring

Segmental ring types provided by F P McCann: Segments in stock are front bolted. Back bolted segments are available to order: Cross joint Corbel Ring Building Manual for F P McCann `Smoothbore Shaft Linings with EPDM Gaskets (rev 04) (To be read in conjunction with the Segmental Shaft and Tunnel Safety Data Sheet) Segmental ring types provided by F

More information

STANDARD AND EXAMPLE DRAWINGS

STANDARD AND EXAMPLE DRAWINGS STANDARD AND EXAMPLE DRAWINGS DRAWING ISSUE TITLE GENERAL CA01-1-1 E EXAMPLE CATCHMENT PLAN - DESIGN BASIS CA01-1-2 D EXAMPLE PRESSURE MAIN CHARACTERISTIC CURVE CA01-1-3-1 B TYPE 10, 40 AND 90 PUMPING

More information

INVITATION FOR BID (IFB) IFB NO. GSWA

INVITATION FOR BID (IFB) IFB NO. GSWA INVITATION FOR BID (IFB) IFB NO. GSWA-005-16 AGAT AND MALOJLOJ RESIDENTIAL TRANSFER STATION IMPROVEME AND DEDEDO RESIDENTIAL TRANSFER STATION CLOSURE ADDENDUM NO. 6 September 22, 2016 ALL BIDDERS MUST

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

REQUEST FOR BIDS WELL #4 ABANDONMENT

REQUEST FOR BIDS WELL #4 ABANDONMENT REQUEST FOR BIDS WELL #4 ABANDONMENT Department of Public Services 1015 S Lincoln Avenue Three Rivers, MI 49093 (269) 273-1845 Table of Contents Well #4 Abandonment... 8 Performance Bids... 8 I. Instructions...

More information

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846

Proposal PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y. Baker, MT P.O. Box 846 PROJECT MANUAL P R O P E R T Y M A N A G E M E N T F A L L O N C O U N T Y Proposal P.O. Box 846 Baker, MT 59313 P R E C A S T R E I N F O R C E D C O N C R E T E B O X C U L V E R T F O R W E S T M O

More information