SURVEYOR SURVEYOR + ODOT DESIGN 1 DESIGN 2 RESE T DESIGN 3 DESIGN 4 C/L X MON. CAP DESIGN NAME NAME or COMPANY ODOT o rlpa R/W PS or ODOT o rlpa R/W P

Size: px
Start display at page:

Download "SURVEYOR SURVEYOR + ODOT DESIGN 1 DESIGN 2 RESE T DESIGN 3 DESIGN 4 C/L X MON. CAP DESIGN NAME NAME or COMPANY ODOT o rlpa R/W PS or ODOT o rlpa R/W P"

Transcription

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17 SURVEYOR SURVEYOR + ODOT DESIGN 1 DESIGN 2 RESE T DESIGN 3 DESIGN 4 C/L X MON. CAP DESIGN or COMPANY ODOT o rlpa R/W or ODOT o rlpa R/W NO NO or COMPANY NO and/or COMPAN Y SURVEYOR SURVEYOR 2" MIN. DIA. ALUMINUM CA PLAN VIEW + + NO RESE T C/L REF. X MON. DESIGN 5 DESIGN 6 + ODOT or or COMPANY SIDE VIEW OF CAP ODOTo rlpa ODOTo rlpa NO or COMPANY NO and/or COMPAN Y 3" MIN. DIA. 3" MIN. DIA. ALUMINUM CAP ALUMINUM CAP PLAN VIEW PLAN VIEW + Furnish a positional mark after monument is constructed. Ensure positional mark is either a Punch Mark or a Chisled X. 1 " min. 1 " min. " min. Varies 42" min.## 6" 6" APPLICATION Right-of-Way E Parcels & Non-Right-of-Way Set on R/W Centerline Offset from R/W Centerline TYPE A MONUMENT TYPE A C A C MONUMENT TYPE 3" min. dia. Aluminum Cap Ground Line 2" min. dia. Aluminum Cap Ground Line Steel Rod. " min. dia., 36" long Steel Rod, Class C Concrete " min. dia., cast-in-place 30" long * Use a circular form for the upper 6" of the cast-in-place monument. ## Ensure the lower 36" of the cast-in- place monument is not formed. 8" dia. CAP DESIGN NOTES TYPE PAY ITEM DESCRIPTION 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Reference Monument 623 Monument Assembly 623 Reference Monument 623 Monument Assembly - Monument Types A & are typically set outside pavement areas. - During construction the contractor will install the Monument Assemblies and Reference Monuments at locations specified in the Right-of-Way plans. - Monument Type C is typically set in pavement areas. - All Reference Monuments and Right-of-Way Monuments set and/or reset by - Cap Designs 3 and 4 are to be installed when the Right-of-Way Monuments are the contractor s surveyor will include an aluminum cap according to this drawing. disturbed, destroyed, and/or damaged by construction activities and are to be reset. - Right-of-Way Monuments are typically set prior to construction and are expected to be protected during construction unless otherwise specified in the plans. THIS DRAWING REPLACES RM-1.1DATED STDS. STATE OF OHIO DEPARTMENT OF TRANSPORTATION ENGINEER O FFICE O F SCD NUMER STANDARD ROADWAY CONSTRUCTION DRAWING RO A D W A Y M O NU M ENTS RO A D W A Y ENGINEERING M. Ruppe ADMINISTRATOR DATE R M

18 1" A A PLAN VIEW SECTION C-C Recessed Letter 6" I.D. Pipe, 33 1/2" long max. Steel Rod 1" min. dia., x 36" long, square cut end and ground smooth Concrete Sand Compacted by Flooding Class C Concrete 12" thick ) 18" min. ) 8" 9" 16" 18" min. One " x 2" stainless steel Hex Head olt Countersunk (Drill & Tap Frame) " 8" 9 " 16 " 1" C C SIDE VIEW MONUMENT TYPE C 3" min. 12" 6" Fasten Cover to Frame with "x2" Stainless Steel Hex Head olt Cover Pavement Surface Adjustment Frame Steel Rod 1" min. dia., x 36" long, square cut end and ground smooth 6" I.D. Pipe, 33" long max. Concrete Sand Compacted by Flooding ) 32 " min. 12 " min. Adjustable Frame " (Typ.) " (Typ.) Class C Concrete 12" thick Recessed Letter olt Pad " (Typ.) 9 " 9" 8" 6" 2ft 7" 7" 16" SECTION A-A 9" 1" 1" 6" 7" 7" 16" SECTION - " Chamfer " (Typ.) 1" " (Typ.) 10 " 3" 1 " 12 " THIS DRAWING REPLACES RM-1.1DATED SCD NUMER R M-1.1 STANDARD ROADWAY CONSTRUCTION DRAWING O FFICE O F STDS. STATE OF OHIO DEPARTMENT OF TRANSPORTATION ENGINEER RO A D W A Y M O NU M ENTS RO A D W A Y ENGINEERING M. Ruppe ADMINISTRATOR DATE

19 SURVEYOR SURVEYOR + ODOT DESIGN 1 DESIGN 2 RESE T DESIGN 3 DESIGN 4 C/L X MON. CAP DESIGN or COMPANY ODOT o rlpa R/W or ODOT o rlpa R/W NO NO or COMPANY NO and/or COMPAN Y SURVEYOR SURVEYOR 2" MIN. DIA. ALUMINUM CA PLAN VIEW + + NO RESE T C/L REF. X MON. DESIGN 5 DESIGN 6 + ODOT or or COMPANY SIDE VIEW OF CAP ODOTo rlpa ODOTo rlpa NO or COMPANY NO and/or COMPAN Y 3" MIN. DIA. 3" MIN. DIA. ALUMINUM CAP ALUMINUM CAP PLAN VIEW PLAN VIEW + Furnish a positional mark after monument is constructed. Ensure positional mark is either a Punch Mark or a Chisled X. 13/4" min. 3/4" min. Varies 42" min.## 6" 6" APPLICATION Right-of-Way E Parcels & Non-Right-of-Way Set on R/W Centerline Offset from R/W Centerline TYPE A MONUMENT TYPE A C A C MONUMENT TYPE 3" min. dia. Aluminum Cap Ground Line 2" min. dia. Aluminum Cap Ground Line Steel Rod. 3/4" min. dia., 36" long Steel Rod, Class C Concrete " min. dia., cast-in-place 30" long * Use a circular form for the upper 6" of the cast-in-place monument. ## Ensure the lower 36" of the cast-in- place monument is not formed. 8" dia. CAP DESIGN NOTES TYPE PAY ITEM DESCRIPTION 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Right-of-Way Monument 623 Reference Monument 623 Monument Assembly 623 Reference Monument 623 Monument Assembly - Monument Types A & are typically set outside pavement areas. - During construction the contractor will install the Monument Assemblies and Reference Monuments at locations specified in the Right-of-Way plans. - Monument Type C is typically set in pavement areas. - All Reference Monuments and Right-of-Way Monuments set and/or reset by - Cap Designs 3 and 4 are to be installed when the Right-of-Way Monuments are the contractor s surveyor will include an aluminum cap according to this drawing. disturbed, destroyed, and/or damaged by construction activities and are to be reset. - Right-of-Way Monuments are typically set prior to construction and are expected to be protected during construction unless otherwise specified in the plans. THIS DRAWING REPLACES RM-1.1DATED STDS. STATE OF OHIO DEPARTMENT OF TRANSPORTATION ENGINEER O FFICE O F SCD NUMER STANDARD ROADWAY CONSTRUCTION DRAWING RO A D W A Y M O NU M ENTS RO A D W A Y ENGINEERING M. RUPPE ADMINISTRATOR DATE R M

20 1" A A PLAN VIEW SECTION C-C Recessed Letter 6" I.D. Pipe, 33 1/2" long max. Steel Rod 1" min. dia., x 36" long, square cut end and ground smooth Concrete Sand Compacted by Flooding Class C Concrete 12" thick ) 18" min. ) 8" 9" 16" 18" min. One " x 2" stainless steel Hex Head olt Countersunk (Drill & Tap Frame) " 8" 9 " 16 " 1" C C SIDE VIEW MONUMENT TYPE C 3" min. 12" 6" Fasten Cover to Frame with "x2" Stainless Steel Hex Head olt Cover Pavement Surface Adjustment Frame Steel Rod 1" min. dia., x 36" long, square cut end and ground smooth 6" I.D. Pipe, 33" long max. Concrete Sand Compacted by Flooding ) 32 " min. 12 " min. Adjustable Frame " (Typ.) " (Typ.) Class C Concrete 12" thick Recessed Letter olt Pad " (Typ.) 9 " 9" 8" 6" 2ft 7" 7" 16" SECTION A-A 9" 1" 1" 6" 7" 7" 16" SECTION - " Chamfer " (Typ.) 1" " (Typ.) 10 " 3" 1 " 12 " THIS DRAWING REPLACES RM-1.1DATED SCD NUMER R M-1.1 STANDARD ROADWAY CONSTRUCTION DRAWING O FFICE O F STDS. STATE OF OHIO DEPARTMENT OF TRANSPORTATION ENGINEER RO A D W A Y M O NU M ENTS RO A D W A Y ENGINEERING M. RUPPE ADMINISTRATOR DATE

24" B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3 " X501 Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOT

24 B B Joint X501 Joint See MARKINGS Note PCB-RXX-350-TL3  X501 Y301 (Typ.)  A PLAN (reinforced casting option shown) A  dia. Hinge Bar (Typ.) NOT B B Joint Joint See MARKINGS Note PCB-RXX-350-TL3 " Y301 (Typ.) " A PLAN (reinforced casting option shown) A " dia. Hinge Bar (Typ.) NOTES GENERAL: This barrier may be manufactured with reinforcing steel

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

Tube Specialty Tools

Tube Specialty Tools Tube Specialty Tools Just as there are different reasons for finishing the cut ends of pipe or tubing, there are different tools and methods for doing the job. 1. Often, the only reason for finishing the

More information

Installation Instructions

Installation Instructions Column & Beam Units with Debris Netting Installation Instructions Laminated Wood Systems, Inc. Seward, Nebraska 800-949-3526 2015 LWS, INC. AVR-NET INSTALL 05-12-16 AVR Installation Notes 1 Safety The

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLine Series 1180 DuraLine Series Class-A Fire Rated IMPORTANT: Review these instructions thoroughly prior to installation. FLOOR ANCHORED

More information

New Product Release: October 2014 Boone Racks

New Product Release: October 2014 Boone Racks New Product Release: October 2014 Boone Racks Double Fido Fountain Mounting: Surface NOTE: THESE ROUGH-IN DIMENSIONS MAY VARY ½: (13 mm) PLUS OR MINUS NOTE: All dimensions subject to manufacturing variance

More information

TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS

TYPICAL STANDOFF GLASS RAIL ELEVATION TYPICAL SECTION RS0B20 WITH RECTANGULAR BACK PLATE TYPICAL STAIRS Revisions By: CRL SRS STANDOFF RAILING SYSTEM CRL GLASS RAIL S RS0B20 w/ RECTANGULAR BACK PLATE CRL'S GLASS RAIL S CAN BE USED FOR MOUNTING GLASS PANELS UP TO 3/4" (19 MM) IN THICKNESS. THE 4" X 8" (102

More information

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter Aluminess Products Inc 9402 Wheatlands Ct. #A Santee, CA 92071 619-449-9930 TIRE RACK INSTALLATION INSTRUCTIONS 07-11 Dodge Sprinter Please read before beginning Stainless steel hardware may bind together

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS COMPACT LAMINATE TOILET PARTITIONS 1080 DuraLineSeries 1180 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information

More information

OFFICE OF MANAGEMENT AND FINANCE

OFFICE OF MANAGEMENT AND FINANCE CITY OF PORTLAND OFFICE OF MANAGEMENT AND FINANCE Charlie Hales, Mayor Fred Miller, Chief Administrative Officer Ken Rust, Director, Bureau of Revenue and Financial Services Christine Moody Chief Procurement

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS SOLID PHENOLIC TOILET PARTITIONS 1080 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and Handling Information on last page. Review

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

Appendix C Construction Details

Appendix C Construction Details 7172 Kennedy Road Warrenton, Virginia 20187 Appendix C Construction Details November 2017 TABLE OF CONTENTS THRUST BLOCKS Anchorage for 11 1/4 o, 22 1/2 o & 45 o Upper Vertical Bends... AV 01 Buttresses

More information

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C) FIG. 10 FIG. 15 & 15L Function: Designed for use in pipe hanger assemblies. (Type 304 or 316 Stainless Steel upon request) Ordering: Specify figure number, rod size, length (), material, and finish. 650

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS HIGH PRESSUE LAMINATE (HPL) TOILET PARTITIONS 1030 TrimLineSeries 1040 DesignerSeries Includes continuous hardware option.65. IMPORTANT: Storage and Handling Information on last

More information

STEEL ANCHOR BASES ALUMINUM ANCHOR BASES

STEEL ANCHOR BASES ALUMINUM ANCHOR BASES max. (Alum.) 20" max. (teel) (ee Note 9) Concrete Foundation Plate 8" x (Typ.) AT-A AT-C Bolt Circle ON TRANFORMER BAE BOTTOM OF BAE (ee Note 8) CONNECTOR 1" 1 " pecial Flat asher Š" - " Tapped Hole for

More information

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter

PRODUCT INFORMATION. ASTM B633,SC1, Type III (Fe/Zn 5) Rod/Anchor Diameter PRODUCT INFORMATION Internally Threaded Expansion Anchor PRODUCT DESCRIPTION The is an all-steel, machine bolt anchor available in carbon steel. It can be used in solid concrete, hard stone, and solid

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED INSTALLATION INSTRUCTIONS MAXIMUM PRIVACY COMPACT LAMINATE TOILET PARTITIONS 2080 DuraLineSeries 2180 DuraLineSeries Class-A Fire Rated Includes Institutional Hardware Option.67 IMPORTANT: Storage and

More information

HEADED ANCHOR BOLT OPTION

HEADED ANCHOR BOLT OPTION Ground Rod 18" min. Depth, 2 Required nchor Bolts. Number (min. 8) and Size as Required by Manufacturer. 6" to 12" Ground Line " dia. Conduit Number and Direction as Shown on Lighting Layout Sheets. Slope

More information

Engineering Design Representation. Use of 2D drawing format: Typical Design Annotation. Standardization. Extracted drawings. General dimensions

Engineering Design Representation. Use of 2D drawing format: Typical Design Annotation. Standardization. Extracted drawings. General dimensions Engineering Design Representation Some elements of design representation not easily conveyed through model alone. Many are notational in nature. Examples are: Thread specifications Surface finishes Surface

More information

Machine Your Fishing Reel

Machine Your Fishing Reel Machine Your Fishing Reel You will be well prepared for the coming season if you start on this smooth-running job now. IF you're an enthusiastic fisherman and have a lathe in your workshop, we'll say no

More information

TYPE 4-C TYPE 6 TYPE 7 TYPE 8

TYPE 4-C TYPE 6 TYPE 7 TYPE 8 ````` Face of ase rad. 42 TYPE rad. " T T T 22.5 2'- unless otherwise shown on plans 5" 5" 5" Slope 2: TYPE 2 rad. Concrete TYPE 2-A rad. Wearing Course Concrete ase Course TYPE 2-0" rad. TYPE 3 As Shown

More information

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC STANDARD SPECIFICATION SECTION 05121 MISCELLANEOUS METALWORK PART 1 - GENERAL 1.01 DESCRIPTION This section includes materials, fabrication, and installation of structural steel, connecting bolts, pipes,

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS MAXIMUM PRIVACY HIGH PRESSURE LAMINATE (HPL) TOILET PARTITIONS 2030 TrimLineSeries 2040 DesignerSeries IMPORTANT: Storage and Handling Information on last page. Review these instructions

More information

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D

Manhole or Catch Basin Type A & B Cone Sections Precast - Design F Manhole or Catch Basin Cover (Reducer Cone Section Precast) Design D MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management and Technical Support, Design Support Section TRANSMITTAL LETTER NO. (14-02) MANUAL: Standard

More information

POWER-Drop Drop-In Anchors

POWER-Drop Drop-In Anchors POWER-Drop Drop-In Anchors Description The POWER-Drop Drop-In anchor provides wedge anchor performance with the convenience of a drop-in anchor. The safety shoulder supports the clip when the anchor is

More information

PTICALTARGETING SPECIALTIES

PTICALTARGETING SPECIALTIES PTICALTARGETING SPECIALTIES 1 2 3 FOUNDATION TARGET INSERT FTI CONSTRUCTION BALL / TARGET PAD CBTP TARGET PAD TRP 3 1/2-8 TO 5/8-11 INSTRUMENT ADAPTOR 4 MAGNETIC BASE TARGET HOLDER ADAPTOR MBTHA CONSTRUCTION

More information

NORTH AMERICA ONLY PIPE SLUG CHUTE DETAILS ALL DIMENSIONS IN INCHES

NORTH AMERICA ONLY PIPE SLUG CHUTE DETAILS ALL DIMENSIONS IN INCHES "B" B. C. PIPE SLUG CHUTE DETAILS ALL DIMENSIONS IN INCHES PVC - DWV PIPE FITTINGS FOR "X" SOC. HD. SCREW (N) HOLES "D" "C" "A" O.D. ALTER IF CONSTRAINED BY SPACE LIMITATION. (2) MIN. FASTENING HOLES REQUIRED.

More information

KOLO SHELTER Installation Instructions Parts List

KOLO SHELTER Installation Instructions Parts List Parts List Roof Cap Rafter Upright Polycarbonate Polycarbonate Drop Polycarbonate Flange Center Weldment (Short length shown above) Polycarbonate Edge Bolt.25 x 6.5 Bolt.625 x 7.5 Threaded Rod.75 x 14

More information

2' x 3' Polymer Pull Box Cover 4'-0" 7'-0" 24" x 76" Access Opening 3'-6"

2' x 3' Polymer Pull Box Cover 4'-0 7'-0 24 x 76 Access Opening 3'-6 Scope.1 Precast Concrete Equipment Slab Box 8' x 10' x Pad with 4' x 7' x 3'- Box for 5-Way RAM Gas Switch, 2-Way, 3-Way, and 4-Way Pad-Mounted RAG Gas Switches, VFI 9, VFI 12, Bypass Switch, and 33 kv

More information

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification.

MATERIAL COMBINATION NUMBER 2: Corrosive environment requiring harder, wear-resistant seating faces and resistance to dezincification. Cast Iron Slide Gates Spec Sheet General The contractor shall furnish and install the following cast iron slide gate assemblies as listed on the Gate Schedule and detailed on the manufacturer s drawings.

More information

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch

RAIL PANEL AT TRANSITION SECTION PLAN - POST DETAIL PLAN - TUBE SPLICE. Colorado Department of Transportation. Staff Bridge Branch Limits of pay length for Bridge RailType 10M (For post spacing, see Dwg. No. B ) B60610 (Use with B60610A) 8 min. 1 max. 8 min. 1 max. 10 0 Max. 10 0 Max. post spacing 10 0 Max. 2 5 Post 1 x 1 slotted

More information

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas

Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Installation Instructions Bulletin 237029 Foundation Specifications for 5.6-Meter Modular Earth Station Antennas Revision A Introduction This document specifies typical foundation characteristics, designs,

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information

This addendum forms a part of the Contract Documents dated: August 10, 2012.

This addendum forms a part of the Contract Documents dated: August 10, 2012. Addendum # 1 Date Issued: August 28, 2012 Issued By: Project: Owner: Renker Eich Parks Architects 1609 Dr. Martin Luther King Street North St. Petersburg, Florida 33704 Ph# (727) 821-2986 Fax # (727) 896-4911

More information

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS

7141 & NATIONAL POLE VAULT STANDARDS SPECIFICATIONS SPECIFICATIONS Specifications: This standard has a clamping system and a handle added for ease of operation. The clamping system is above the base pad protectors when in the lowest position and the tightening

More information

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas

Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Installation Instructions Foundation Specifications for 7.6-Meter Modular Earth Station Antennas Bulletin 237186A Revision A Introduction This document specifies typical foundation characteristics, designs,

More information

STEEL PIPE GUIDERAIL 01/01/

STEEL PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Pipe Rails and s shall be in accordance with ASTM A5 Grade B for standard weight pipe and ASTM A500 Grade B, C or D or ASTM A50 for structural tube. Bars for handrail supports

More information

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG Waterpipe Ground Ground Wire Size Water Pipe Size 2-T 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 WG 2-1/2 in., 3 in. or 3-1/2 in. 5-T 4 in., 4-1/2 in. or 5 in. 6 6

More information

HOME WORKSHOP HANDBOOK Rugged BENCH GRINDER. By JOEL B. LONG

HOME WORKSHOP HANDBOOK Rugged BENCH GRINDER. By JOEL B. LONG 6 HOME WORKSHOP HANDBOOK Rugged BENCH GRINDER W By JOEL B. LONG ITH this bench grinder you can keep your cutting tools sharp and do general offhand grinding, and can, with the aid of various attachments,

More information

1-1/4 PIPE 36-1/2 VERTICAL 1-1/4 PIPE 42-1/2 VERTICAL. Wa gner Companies FAX:

1-1/4 PIPE 36-1/2 VERTICAL 1-1/4 PIPE 42-1/2 VERTICAL. Wa gner Companies FAX: WALL MOUNT PAD (OPT.) 1-1/4 PIPE 36-1/2 VERTICAL S/S 1X19 STRAND END POST TOP RAIL INTERMEDIATE POST WALL MOUNT PAD (OPT.) CABLE BRACE (OPT.) FOOT PADS CORNER SECTION ASSY. (OPT.) 1-1/4 PIPE 42-1/2 VERTICAL

More information

Modular Gazebo Kit Series Victorian / Queen Anne 9

Modular Gazebo Kit Series Victorian / Queen Anne 9 Octagonal CUPOLA louvered (electrical optional) Modular Gazebo Kit Series Victorian / Queen Anne 9 with SINGLE-TIERED Roof Lumber: Western Red CEDAR #1 (Cabinet) or #D and Better (Carpentry) Shingles:

More information

Installation Instructions

Installation Instructions Installation Instructions For Models: Model Number / Description File Name 1540 Classic Series P-Lam Toilet Partitions 1540.pdf 1 INSTALLATION INSTRUCTIONS LAMINATED PLASTIC TOILET PARTITIONS 1540 Classic

More information

DC3210. Recommended Closer Size

DC3210. Recommended Closer Size Installation Instructions For Non-Hold Open or A Hold Open Arm Option DC3200 Series Multi-Sized thru 6 Regular Arm Universal Door Closers Parallel Arm Jamb Mount See pages 2&3 See pages 4&5 See pages 6&7

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION Soild Phenolic Series contents page 1080 DuraLineSeries...2-21 1180 DuraLineSeries...2-21 2080 DuraLineSeries Maximum Privacy...22-41 2180 DuraLineSeries Maximum Privacy...22-41

More information

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012)

2. Remove from the Standard Plate manual: Standard Plate Index, Sheets 1-4 of 4, Numerical Index of Standard Plates (August 31, 2012) MINNESOTA DEPARTMENT OF TRANSPORTATION DEVELOPED BY: Design Standards ISSUED BY: Office of Program Management & Technical Support, Design Support Section TRANSMITTAL LETTER NO. (12-04) MANUAL: Standard

More information

Technical Specifications Guide For Fasteners

Technical Specifications Guide For Fasteners fastrite_2011_fut.ai 8/4/11 4:29:01 PM Technical Specifications Guide For Fasteners C M Y CM MY CY CMY K Important Disclaimer All of the information provided in this publication is intended for reference

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility B 64" 1626 602'-8 1/16" 183695 548'-0" 167030 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 373839 40 25 IMPACT 1500A 48" 12 27'-5" 8355 [] 3x7 CL A Galvanized

More information

CONCRETE MANHOLES.

CONCRETE MANHOLES. CONCRETE CONCRETE SHAW PIPE produces circular, precast, concrete manholes in diameters 1050mmØ through 3000mmØ. Precast, concrete manholes are most frequently used for pipeline and sewer entry and are

More information

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW A21-1 1160 CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD S For light duty applications in solid materials Color coded diameters for easy identifi cation Acid resistant NYLON FLANGED:

More information

CSS Central Mount System

CSS Central Mount System CSS-20 Installation Manual CSS-20 Safety Notifications Below are the installation instructions for the CSS-20-2 Long Span Beam Mounting System. Please read these safety notifications prior to beginning

More information

A Reference Guide. Continuous Hinge, Inventory and Service Worldwide Est End Play Design Engineering with Standard Continuous Hinges

A Reference Guide. Continuous Hinge, Inventory and Service Worldwide Est End Play Design Engineering with Standard Continuous Hinges Hinge Width Paint Clearance Knuckle Length End Play Design Engineering with Standard Continuous Hinges A Reference Guide Knuckle Dear Design Engineer or Purchasing Agent, We frequently see blueprints for

More information

The ribbed L Rivet Nut Series features a large flange head configuration with a ribbed body.

The ribbed L Rivet Nut Series features a large flange head configuration with a ribbed body. The ribbed L Rivet Nut Series features a large flange head configuration with a ribbed body. RIBBED BODY The ribbed body provides increased resistance from spinning. LARGE HEAD Provides a large bearing

More information

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg)

Part No. Thread Size B Design Load Approx. Wt./100 A in. (mm) Lbs. (kn) Lbs. (kg) ttachments Fig. 3199R - eiling Flange Fig. 3199RT - eiling Flange ura-opper oated Size Range: 3 /8"-16 & 1 /2"-13 rod Material: Malleable Iron (Stainless Steel Type 304 available) Standard 3199RT is UR-OPPER

More information

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg

F-5-1a. Concrete Bollards (Detail 1 of 2) WEIGHT: 166kg. WEIGHT: 227kg. WEIGHT: 113kg. WEIGHT: 212kg Contents F-5-1a Concrete Bollards F-5-1b Concrete Bollards F-5-2 Concrete Bollards with City Logo F-5-3 Cast Iron Bollards F-5-4 Decorative Steel Bollard F-5-5 Swivel P Gate Steel Bollard F-5-6 Steel Bollard

More information

Captive Quarter-turn Fasteners Continuous Receptacle Strip MIL-F-25173A * APPROVED

Captive Quarter-turn Fasteners Continuous Receptacle Strip MIL-F-25173A * APPROVED Solutions Inc. PA-3500 Line Captive Quarter-turn Fasteners Continuous Receptacle Strip MIL-F-25173A * APPROVED The DFCI PA-3500 Line of fasteners combine the operating convenience, predictable clamping

More information

TAPPING SCREWS 1-1 TAPPING SCREWS PHILLIPS OVAL. 1 General Fasteners HEAD ZINC BLACK SIZE SIZE CHROME CHROMATE OXIDE

TAPPING SCREWS 1-1 TAPPING SCREWS PHILLIPS OVAL. 1 General Fasteners HEAD ZINC BLACK SIZE SIZE CHROME CHROMATE OXIDE TAPPING SCREWS TAPPING SCREWS PHILLIPS OVAL HEAD ZINC BLACK SIZE SIZE CHROME CHROMATE OXIDE #4 x 3/8"... REG... 110001 #4 x 1/2"... REG... 105030... 110002 #4 x 5/8"... REG... 1 10003 #4 x 3/4"... REG...

More information

STANDARD "T" HANDLE CLAMPS

STANDARD T HANDLE CLAMPS STANDARD "T" HANDLE CLAMPS Standard "T" Handles 401 1" 405 2" 410 3" 420 6" 430 9" 440 12" Multi-purpose clamps combine the best features of ordinary "C" and parallel clamps. Free-floating jaws adjust

More information

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc

1/4 Turn Fastener - Black Painted Zinc 1/4 Turn Fastener - Stainless Steel 1/4 Turn Cam,.649 Offset - Zinc ACCESSORIES Y001721 Y001722 Y001723 Y001724 Y001725 Y001726 Y001160 Y001363 Y001442 Y001184 Y002192 Y002193 PART NUMBER Y001721 Y001722 Y001723 Y001724 Y001725 Y001726 Y001160 Y001363 Y001442 Y001184 Y002192

More information

HOLLOW CORE PRODUCTS GROUNDED IN STRENGTH

HOLLOW CORE PRODUCTS GROUNDED IN STRENGTH HOLLOW CORE PRODUCTS GROUNDED IN STRENGTH usable space under your garage 8 form - 8 Hollow Core 7' - 11-1/2" 3" min. topping for precast diaphragms 2-3/ 3" MIN. TOPPING FOR PRECAST DIAPHRAGMS 7' - 11-3/4"

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS LAMINATED P LASTIC TOILET PArTITIONS 1540 ClassicSeries with Options IMPORTANT: Storage and Handling Information on last page. For faster, easier installation, please review these

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

AUXILIARY FRAMING AND ACCESSORIES

AUXILIARY FRAMING AND ACCESSORIES CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION

More information

METRIC FA S T E N E R S

METRIC FA S T E N E R S METRIC FASTENERS CAP SCREWS & BOLTS DIN 603 Carriage Bolt, A2 SS DIN 603 Carriage Bolt, A4 SS DIN 931 Class 8.8 Hex Cap Screw, Steel Zinc DIN 931 Class 10.9 Hex Cap Screw, Plain Steel DIN 933 Class 8.8

More information

CAPTUR COMPONENTS. We make food look better.

CAPTUR COMPONENTS. We make food look better. CAPTUR COMPONENTS TOP EDGE GLASS CONNECTORS GCA6 6mm (1/4") Glass GCA10 10mm (3/8") Glass 2.76 2.90 2.76 2.90 TOP BOTTOM 1.13 1.13 6mm GLASS GC906 6mm (1/4") Glass 10mm GLASS GC9010 10mm (3/8") Glass Adjustable

More information

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0" 7-6" 8-0" 6-0" Truss Depth. 3" sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T.

(50 FT FT) MICHIGAN DEPARTMENT OF TRANSPORTATION 10-0 7-6 8-0 6-0 Truss Depth. 3 sheets 5 & 6 of 10) DEPARTMENT DIRECTOR. Kirk T. Column truss connection (See details sheets 3 & 4 of 10) \ Span (Odd number of panels) \ Span (Even number of panels) Back truss chord Top truss chord \ Truss Chord splice Truss depth (See details \ Left

More information

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series

Football Goal Posts MODEL SERIES: FGP400 and FGP600 series Football Goal Posts MODEL SERIES: FGP400 and FGP600 series Installation and Maintenance Instructions Please read all instructions before attempting installation of these units SAVE THESE INSTRUCTIONS FOR

More information

Modular Gazebo Kit Series Victorian or Queen Anne 12

Modular Gazebo Kit Series Victorian or Queen Anne 12 Octagonal CUPOLA with fixed louvers (standard light fixture optional) Modular Gazebo Kit Series Victorian or Queen Anne 12 with DOUBLE-TIERED Roof Lumber: Western Red CEDAR Cabinet = #1 or Carpentry =

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

CLWP6048. Classic Sign Family Wall Panel. Part Number / Specifications. 60" Wide x 48" High CHPL Panel Wall Mount. ISO / Perspective View.

CLWP6048. Classic Sign Family Wall Panel. Part Number / Specifications. 60 Wide x 48 High CHPL Panel Wall Mount. ISO / Perspective View. ISO / Perspective View Dwg. Date: pril 7, 25 ll Drawings Copyright. WP6048HRS (Single-Sided) Standard - Rectangular Panel C Upgrade Panel Option - Horizontal rched WP6048HPS (Single-Sided) Upgrade - Peaked

More information

APPENDIX FENCE GENERAL NOTES

APPENDIX FENCE GENERAL NOTES APPENDIX FENCE GENERAL NOTES 1. Fabric: 9 gage, 2" mesh, knuckle top and bottom, placed on the outside of posts, single fabric width for the entire height. 2. All fencing to be standard galvanized finish.

More information

STORM M ANHOLE FOR 42" PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30"MAX 3 OR 3.5 PRECAST ECCENTIC CONC

STORM M ANHOLE FOR 42 PIPE AND SM ALLER JOB NO. SHEET NO. DATE MARCH 2015 OF MIN OF 3 CRSES MAX OF 5 CRSES 30MAX 3 OR 3.5 PRECAST ECCENTIC CONC 01-APR-2015 13:33 = I:\MSV8i\Plotting\piblack.ptb V:\201001\\C\8x11_Howell_Det\stm_det01_8x11_st01.dgn TIME = MIN 3 CRSES MAX 5 CRSES 3 OR 3.5 PRECAST ECCENTIC CONC ID PIPE GRADE A CONC FILL 4" 8" 2-0"SUMP

More information

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS CRL JACKSON INSTALLATION INSTRUCTIONS CRL JACKSON 3185 MID-PANEL CONCEALED VERTICAL ROD PANIC EXIT DEVICE crlaurence.com Phone: (800) 421-6144 Fax: (866) 921-0531 crlaurence.com usalum.com crl-arch.com 11M0252 ORDER

More information

AAE Model No. PVS-HSX High School Premier Pole Vault Standards

AAE Model No. PVS-HSX High School Premier Pole Vault Standards E Model No. PVS-HSX High School Premier Pole Vault Standards luminum thletic Equipment 1000 Enterprise rive, Royersford, P 19468 Toll Free: (800) 53-5471 Fax: (610) 85-378 www.esports.com 8 7 6 5 4 3 1

More information

Power Tool Accessories

Power Tool Accessories Milwaukee Tool MilwaukeeTool.com Power Tool Accessories Band Saw Blades Deep Cut Band Saw Blades Overview Maximize your band saw performance and make straight, accurate cuts in a variety of materials with

More information

EXTERIOR BUILDING, ROOFING, AND SITE IMPROVEMENTS

EXTERIOR BUILDING, ROOFING, AND SITE IMPROVEMENTS CONTRACT NUMBER: IFB-8-B006 ARCHITECT / ENGINEER : HURST-ROSCHE, INC. NO. LINOIS 62203 (68) 398-0890 -7 E. RANDLE ST./ N. FRITZ ST. 402 CHERRY ST., 404-406 ST. LOUIS ST. 502-506 DEE ST. 50-505 PLUM ST.

More information

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP.

FAIRBANKS NIJHUIS 1590 SERIES SINGLE STAGE VERTICAL INLINE PUMP. FAIRBANKS NIJHUIS 0 SERIES SINGLE STAGE VERTICAL INLINE PUMP www.fairbanksnijhuis.com FAIRBANKS NIJHUIS 0 Series Single Stage Vertical Inline Pump Capacities to 00 GPM (,00 m/hr) Heads to 0 Feet ( m) Temperatures

More information

Beam and Purlin Clamps Beam Clamps

Beam and Purlin Clamps Beam Clamps Metal Framing & Cable Tray Steel City Hangers, Clamps & Fasteners Beam and Purlin Clamps Beam Clamps Fits beam flanges to 2" Supports 4" and 8" threaded rod, S-hooks, electrical boxes, conduit and bridle

More information

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC

Peco Fasteners 3/8 Internal Plug Drop In 50 Per Jar 3/8-16 SMART DROP IN ANCHOR ZINC 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-794 Fax: 936-560-4685 Catalog Number Manufacturer Description Weight per unit Product Category 6337J 3/8-6 Smart Drop In Zinc Peco Fasteners,

More information

CLWP2418. Classic Sign Family Wall Panel. Part Number / Specifications. 24" Wide x 18" High CHPL Panel Wall Mount. ISO / Perspective View.

CLWP2418. Classic Sign Family Wall Panel. Part Number / Specifications. 24 Wide x 18 High CHPL Panel Wall Mount. ISO / Perspective View. CLWP2418 ISO / Perspective View Dwg. Date: pril 7, 25 Temple, TX 765 CLWP2418. CLWP2418 WP2418HRS (Single-Sided) Standard - Rectangular Panel C Upgrade Panel Option - Horizontal rched WP2418HPS (Single-Sided)

More information

K/D FITTINGS & FASTENERS

K/D FITTINGS & FASTENERS K/ FITTINGS & FASTENERS -1 Screws P. 162-168 -2 Connector Bolts P. 169-173 -3 K/ Fittings P. 174-177 -4 Insert Nuts P. 178-181 -5 Allen Keys P. 182-183 -6 Nails & Wall Plugs P. 184 -1 Screws 1010 Machine

More information

A - Railing Frame Material Specifications

A - Railing Frame Material Specifications A - Railing Frame Material Specifications NOTE: We strongly recommend stainless steel for exterior applications. R-1 8/1/02 B Stainless Steel Spacers (For Horizontal Railing Double Post End Post using

More information

STANDARD BID ITEM NUMBERS

STANDARD BID ITEM NUMBERS 10701 TRAFFIC CONTROL LUMP SUM 10702 Traffic Control for Storm Sewer Installation LUMP SUM 10703 Traffic Control for Water Main Installation LUMP SUM 10704 Traffic Control for Sanitary Sewer Installation

More information

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL "A-1"

SIGN MOUNTED BEACON SIG-027-A SINGLE SIGN MOUNTED FLASHING BEACON INSTALLED ON ONE WOOD POST DETAIL A-1 1 1/2" x 60" Galvanized (thread both ends) Top Bolt See Detail "A-1" and Slotted Channel Parallel Conduit Clamp Warning Sign 3 Equal Bolt Spacings (3 places at 12" min. spacing) (1) 3/8"x 7" min. (4"x

More information

INSTALLATION MANUAL. 2. Check with local utility companies for locations of underground cables or pipe lines.

INSTALLATION MANUAL. 2. Check with local utility companies for locations of underground cables or pipe lines. INSTALLATION MANUAL Install our maintenance free fencing system yourself! About 90% of our residential clientele install our fencing systems themselves. Why hire and pay someone to install it when you

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

ISO INTERNATIONAL STANDARD. Cross recessed raised countersunk head drilling screws with tapping screw thread

ISO INTERNATIONAL STANDARD. Cross recessed raised countersunk head drilling screws with tapping screw thread INTERNATIONAL STANDARD ISO 15483 First edition 1999-08-01 Cross recessed raised countersunk head drilling screws with tapping screw thread Vis autoperceuses à tête fraisée bombée à empreinte cruciforme,

More information

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson.

FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson. FASTENERS PIPE HANGERS, SUPPORTS & STRUT ACCESSORIES FNW can handle all your hanger and fastener needs, all in one place. FNW products are sold exclusively at Ferguson. Quick Reference Nuts Heavy Hex Nuts...4

More information

City of Massillon Site Plan Checklist

City of Massillon Site Plan Checklist City of Massillon Site Plan Checklist The following information MUST be included with all Site Plans submitted for review and processing in order to constitute a complete Site Plan Package. Incomplete

More information

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable)

RG Connector (Molded Mating Extension Cable Required) A H B G. MS Connector (Mating Connector: P/N ; MS3116F-12-10S or Extension Cable) T E M P O S O N I C S L S E R I E S INSTALLATION A N A L O G O U T P U T 550570 B W I R I N G - A N A L O G O U T P U T S RG Connector: (Voltage or Current Output) 1 Gray 0 to 10 Vdc, 4 to 20 ma, or 0

More information

Flooring Nails 6-D Flooring Nails $3.40 / 1# 6-D Flooring Nails $14.50 / 5# 8-D Flooring Nails $3.40 / 1# 8-D Flooring Nails $14.

Flooring Nails 6-D Flooring Nails $3.40 / 1# 6-D Flooring Nails $14.50 / 5# 8-D Flooring Nails $3.40 / 1# 8-D Flooring Nails $14. Nails Nails Drywall Screws Common Nails 4D Common Nails $3.85 / 1# 6D Common Nails $3.00 / 1# 6D Common Nails $74.25 / 50# 8D Common Nails $3.00 / 1# 8D Common Nails $74.25 / 50# 10D Common Nails $3.00

More information

Midwest Roadside Safety Facility

Midwest Roadside Safety Facility 19'-11 1/2" 6083 239'-11 1/2" 73139 Impact 1100C 25 43 5/16" 1100 upstream from the upstream face of the first shear fender downstream of the joint between barrier nos. 7 and 8 Upstream End Downstream

More information

TOOLING COMPONENTS. Clamping Kits Step Blocks & Kits Driver Studs Bolts, Screws Nuts, Washers...

TOOLING COMPONENTS. Clamping Kits Step Blocks & Kits Driver Studs Bolts, Screws Nuts, Washers... TOOLING COMPONENTS Clamping Kits... 2-5 Step Blocks & Kits... 6-7 Driver Studs... 8-12 Bolts, Screws... 13-19 Nuts, Washers... 20-29 Clamps... 30-43 Swivel Screw Clamps... 44-46 Screws... 47-48 Hand Knobs...49

More information

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

Bol FEATURES: SPECIFICATIONS: 8' 24' Round Tapered and Straight Wood Poles STRUCTURA INC. FIXTURE TYPE: PROJECT NAME: Bol 8' 24' Round Tapered and Straight Wood Poles FIXTURE TYPE: PROJECT NAME: Round Taper Glulam solid wood and aluminum pole available in 8' 24' lengths. Tenon adapters, slip fitters and side bracket mounts

More information

Item 550 Chain Link Fence

Item 550 Chain Link Fence Item Chain Link Fence 1. DESCRIPTION 2. MATERIALS Furnish, install, remove, repair, or replace chain link fence and gates. Furnish certification from the chain link fence materials manufacturer stating

More information

Evaluation of In-Pavement Light Fixture Designs and Performance

Evaluation of In-Pavement Light Fixture Designs and Performance Evaluation of In-Pavement Light Fixture Designs and Performance Presented to: IES ALC Fall Technology Meeting By: Joseph Breen Date: Background In-Pavement Light Fixture Assemblies Utilize a Circle of

More information

GAZEBO STRUCTURAL SYSTEM SERIES VKE- 14B MODEL (14 x 19, Double-Tier)

GAZEBO STRUCTURAL SYSTEM SERIES VKE- 14B MODEL (14 x 19, Double-Tier) Elongated CUPOLA solid base (electrical optional) GAZEBO STRUCTURAL SYSTEM SERIES VKE- 14B MODEL (14 x 19, Double-Tier) Lumber: Western Red CEDAR #1 (Cabinet) or #D and Better (Carpentry) Shingles: 5X

More information

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018

STANDARD DRAWINGS INDEX MODIFIED FOR CENTRAL REGION Revised August 6, 2018 SYMBOLS STANDARD DRAWINGS INDEX No Statewide Standard - Use Regional A3 Legend Detail Sheet BRIDGE AND STRUCTURES B-08.00 Bin Walls 1 CONSTRUCTION-BARRICADES AND SIGNING C-04.12 Location of Double Traffic

More information