CLASS H/K5 AND R SERIES FUSEBLOCKS
|
|
- Betty Spencer
- 6 years ago
- Views:
Transcription
1 LASS H/K5 AND R SERIES FUSEBLOKS lip designs maximize electrical contact and minimize heat rise Standard reinforcing clips on all lass R fuseblocks and lass H fuseblocks rated 00 A and higher RoHS compliant, Pb free Description The new Littelfuse lass H and R blocks offer many advantages over previous generations such as indication, snap-to-release DIN Rail mounting, and universal mounting holes. lass H and lass R fuseblocks are dimensionally the same, but lass R blocks incorporate a rejection feature, which only allows lass R fuses to be inserted. This new line of fuseblocks has replaced the previous LH and LR Series blocks. Features/Benefits Indication offered on most 250 V and 600 V versions One hand release from DIN Rail (snap-to-release) for all non-knife blade style fuses Universal mounting holes for easy replacement Ordering Information (lass H 250 V) AMP POLES ATALOG/SYSTEM NUMBER PART NUMBER SUFFIX BOX LUG PRESSURE SREW PLATE Note: Reinforcing springs are standard on all lass H fuseblocks. TORQUE Specifications Voltage Rating: 250 V, 600 V Ampere Ratings: A Leakage urrent: <0.6 ma at 600 V Flammability Rating: UL94 V-0 Approvals: UL Listed (File No. E472) SA ertified (File No. LR709) Recommended Fuses lass H/K5 Blocks 250 V NLN RLN lass R Blocks 250 V FLNR/FLNR_ID KLNR LLNRK TLN lass H/K5 Blocks 600 V NLS RLS lass R Blocks 600 V FLSR/FLSR_ID KLSR LLSRK/LLSRK_ID IDSR Web Resources Sample requests, downloadable AD drawings and other technical information: TERMINAL WIRE RANGE WIRE E TEMP SNAP TO RELEASE LFH2500 P S 6-4 AWG 2 LFH25002 P S 2.8 N-m (25 in-lbs) P 0-4 AWG U Only LFH2500 P S S 0-22 AWG 25 LFH25060 ID 5.6 N-m (50 in-lbs) 2-4 AWG 2 LFH ID U-AL 2.8 N-m (25 in-lbs) 6-4 AWG LFH25060 ID 25 LFH2500 LFH2500 ID ID.6 N-m (20 in-lbs) 2/0-6 AWG 4.5 N-m (40 in-lbs) 8 AWG 4.0 N-m (5 in-lbs) 0-4 AWG U-AL LFH N-m (275 in-lbs) 250 kcmil-6 U-AL LFH25200 LFH N-m (275 in-lbs) (2) 50 kcmil-/0 U-AL LFH25400 LFH N-m (75 in-lbs) (2) 500 kcmil-4 U-AL LFH25600 INDIATION Littelfuse
2 LASS H/K5 AND R SERIES FUSEBLOKS lass H 600 V AMP POLES SYSTEM NUMBER ATALOG/SYSTEM NUMBER SUFFIX BOX LUG PRESSURE PLATE Note: Reinforcing springs standard on all lass H fuseblocks. lass R 250 V AMP Note: Reinforcing springs standard on all lass R fuseblocks. Note: Reinforcing springs standard on all lass R fuseblocks. SREW TORQUE TERMINAL WIRE RANGE WIRE E TEMP SNAP TO RELEASE LFH6000 ID PID SID 6-4 AWG 2 LFH60002 ID PID SID 2.8 N-m (25 in-lbs) P 0-4 AWG U Only 0 LFH6000 ID PID SID S 0-22 AWG LFH60060 ID 5.6 N-m (50 in-lbs) 2-4 AWG 2 LFH ID U-AL 2.8 N-m (25 in-lbs) 6-4AWG 0 LFH60060 ID.6 N-m (20 in-lbs) 2/0-6AWG LFH6000 ID 4.5 N-m (40 in-lbs) 8 AWG U-AL 0 LFH6000 ID 4.0 N-m (5 in-lbs) 0-4 AWG LFH N-m (275 in-lbs) 250 kcmil-6 U-AL 0 LFH60200 LFH N-m (275 in-lbs) (2) 50 kcmil-/0 U-AL 0 LFH60400 LFH N-m (75 in-lbs) (2) 500 kcmil-4 U-AL 0 LFH60600 POLES lass R 600 V AMP SYSTEM NUMBER ATALOG/SYSTEM NUMBER SUFFIX BOX LUG PRESSURE PLATE SREW TORQUE TERMINAL WIRE RANGE WIRE E TEMP SNAP TO RELEASE LFR2500 P S 6-4 AWG 2 LFR25002 P S 2.8 N-m (25 in-lbs) P 0-4 AWG LFR2500 P S S 0-22 AWG U Only 25 LFR25060 ID 2.8 N-m (25 in-lbs) 6-4 AWG 2 LFR25060 LFR ID ID 5.6 N-m (50 in-lbs) 2-4 AWG U-AL 25 LFR2500 ID.6 N-m (20 in-lbs) 2/0-6 AWG 4.5 N-m (40 in-lbs) 8 AWG LFR2500 ID 4.0 N-m (5 in-lbs) 0-4 AWG U-AL 0 LFR25200 LFR N-m (275 in-lbs) 250 kcmil-6 U-AL 0 LFR25400 LFR N-m (275 in-lbs) (2) 50 kcmil-/0 U-AL 0 LFR25600 LFR N-m (75 in-lbs) (2) 500 kcmil-4 U-AL 0 POLES SYSTEM NUMBER ATALOG/SYSTEM NUMBER SUFFIX BOX LUG PRESSURE PLATE SREW TORQUE TERMINAL WIRE RANGE WIRE E TEMP SNAP TO RELEASE LFR6000 ID PID SID 6-4 AWG 2 LFR60002 ID PID SID 2.8 N-m (25 in-lbs) P 0-4 AWG LFR6000 ID PID SID S 0-22 AWG U Only 0 LFR60060 ID 2.8 N-m (25 in-lbs) 6-4 AWG 2 LFR60060 LFR ID ID 5.6 N-m (50 in-lbs) 2-4 AWG U-AL 0 LFR6000 ID.6 N-m (20 in-lbs) 2/0-6 AWG LFR6000 ID 4.5 N-m (40 in-lbs) 8 AWG U-AL N-m (5 in-lbs) 0-4 AWG LFR60200 LFR N-m (275 in-lbs) 250 kcmil-6 U-AL 0 LFR60400 LFR N-m (275 in-lbs) (2) 50 kcmil-/0 U-AL 0 LFR60600 LFR N-m (75 in-lbs) (2) 500 kcmil-4 U-AL 0 INDIATION INDIATION INDIATION Littelfuse
3 LASS H/K5 AND R SERIES FUSEBLOKS 250 V 0 A 5.6 [.6].0 [.5] 4.8 [.9] 28.6 [.] 2.8 [.94] 6. [.64] 6.8 [.27] 48.5 [.9] 2.2 [.27] 5.6 [.22] 74.7 [2.94] 42.9 [.69].8 [.25] 40. [.58] 8.4 [.] 76.5 [.0] [.26] [.5] 44.6 [.76] R2.8 [.] R2.8 [.].2 THRU.6 [.4] 250 V 60 A 22.4 [.88] 4.8 [.58] 9.7 [.8] 7. [.47] 70.7 [2.78] 04. [4.0] 55.8 [2.20] 89.2 [.5] 4. [.70] 76.5 [.0] 57.4 [2.26] 24.9 [.98] 4.9 [.7] 75.7 [2.98] 9.7 [4.7] R2.8 [.] 5.5 [.2] 200 Littelfuse
4 LASS H/K5 AND R SERIES FUSEBLOKS 250 V 00 A 4.7 [.7] 20. [.80]. [.45] 46.0 [.8] 26. [4.97] 00.6 [.96] 9.6 [.6] 60.5 [2.8] 5.5 [2.0] 66.0 [2.60] 22.9 [.90] 72.6 [2.86] 5.6 [2.] R.4 [.].0 [5.2] 77.8 [7.00] 250 V 200 A 6.5 [2.50] 2.7 [.50] 76.2 [.00] 6.5 [2.50] 9. [.75] 2.7 [.50] [9.00] 25.9 [8.50] 84.2 [7.25] 65. [6.50] 72.4 [2.85] 52.6 [2.07] 28.5 [5.06] R4. [.7]. 8. [7.] Littelfuse
5 LASS H/K5 AND R SERIES FUSEBLOKS 250 V 400 A 66.7 [2.6] 22.2 [.88] 88.9 [.50] [0.50] 84.4 [.2] [9.88] 95. [.75] 95. [.75] 08.0 [4.25] 84.2 [7.25] 96.9 [7.75] 292. [.50] 250 V 600 A 4. [4.5] 79.4 [.] 4.9 [.4] 9. [.8] 9. [.8] 7.5 [2.5] [.8] 0.6 [4.4] 5.9 [.6] 4. [4.5] 9.7 [5.5] Ø [4.5] Ø [9.5] 25.9 [8.5] 55.6 [4.0] 200 Littelfuse 5
6 LASS H/K5 AND R SERIES FUSEBLOKS 600 V 0 A 8.4 [.5] 2.5 [.85] 7. [2.88] 07.9 [4.25] 9.2 [.76] 5.6 [2.0] 86.4 [.40] 6.8 [.66] 75.9 [2.99] 4. [.62] 6.4 [.25] 52.5 [2.07] 20.7 [.82] 8.6 [4.67] 27. [5.00] 66.7 [6.56] 47.6 [.87] 56.0 [2.20] R.4 [.] R2.6 [.0] 600 V 60 A 2.4 [.28] 29.8 [.7] 9.9 [.78].4 [.45] 4.8 [.7] 8.6 [.29] 2.2 [4.85] 69.5 [2.74] 09. [4.0] 59.6 [2.5] 99.4 [.9] 59.7 [2.5] 22.9 [.90] 4.6 [5.0] 55.2 [2.8] 74.2 [2.92] R.4 [.].2 THRU [7.25] Littelfuse
7 LASS H/K5 AND R SERIES FUSEBLOKS 600 V 00 A.8 [.] 9.6 [.77] 5.0 [.59] 5.4 [2.0] 45. [5.72] 25.7 [4.95] 07.0 [4.2] 79.8 [.4] 6.0 [2.40] 66.0 [2.60] 22.9 [.90] 64.6 [2.54] R.4 [.] 72.8 [6.80] [9.00] 600 V 200 A 76.2 [.00] 6.5 [2.50] 2.7 [.50] [9.00] 96.9 [7.75] 6.5 [2.50] 65. [6.50] 44.5 [.75].8 [.25] 2.7 [.50] 72.4 [2.85] 5.9 [.6] 60. [6.] 92.0 [7.56] 52. [2.06] 84.2 [.2] Ø [2.06] 76.7 [.02] 84. [.] 60. [6.] 244. [9.62] R4. [.7]. 200 Littelfuse 7
8 LASS H/K5 AND R SERIES FUSEBLOKS 600 V 400 A 88.9 [.50] 7.0 [2.88] 66.7 [2.6] 22.2 [.88] [0.50] [9.88] 84.4 [.2] 95. [.75] 46. [5.75] 222. [8.75] 27. [0.75] 68. [4.50] 600 V 600 A 4. [4.50] 95. [.75] 79.4 [.] 4.9 [.8] 9. [.75] 7.5 [2.50] [.75] 9. [.75] 0.6 [4.6] [0.00] 77.8 [7.00] 4. [4.50] Ø ] Littelfuse
Specifications. Class R Blocks 250 V FLNR/FLNR_ID KLNR LLNRK TLN. Torque N-m (120 in-lbs) 2/0-6 AWG
LF Series lass H/K5 AND R Fuse Blocks Specifications Voltage : 250 V, 600 V Ampere s: 0 600 A Leakage urrent:
More informationLF SERIES CLASS R & H/K5 FUSE BLOCKS
250 V 00 V Specifications Description The Littelfuse Class R and H/K5 blocks offer many benefits such as indication, snap-to-release DIN rail mounting and universal mounting holes. Class H and Class R
More informationonlinecomponents.com
Short-Circuit Current Ratings and Feeder Spacing SCCR Information: Power Distribution Blocks with SCCR and Feeder Spacing The requirements of the National Electric Code (NEC) and UL508A now require many
More informationPower Distribution Blocks with Short-Circuit Current Ratings
Power Distribution Blocks with Short-Circuit Current Ratings General Information: The requirements of the 005 National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short
More informationSectional Terminal Blocks
General Information: Sectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the block producing the required
More informationTable of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance
Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8
More informationHEADER & HOUSING SYSTEMS
dam Technologies, Inc. HEDER & HOUSING SYSTEMS.8mm, 1mm, 1.25mm, 1.5mm, 2mm & 2.5mm INTRODUTION: dam Tech 2H & 2SH Series of multiple pitch Headers and Housings are a matched set of rimp Wire Housings
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More information8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution
Terminal Blocks, Fuse Blocks and Fuse Holders.3 CHDB Series Blocks, Enclosed and Open CHDB Series Blocks Product Description Features and Benefits Eaton s CHDB Series of Blocks was designed for high short
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationTable of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance
Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8
More informationSectional Terminal Blocks
ectional Terminal locks General Information: ectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the
More informationEuroMag Series PCB Mount Terminal Blocks. EM3123 Series Euro-Mag Terminal Blocks 3.50 Centers; Modular. Part Numbering System
EuroMag PCB Mount Terminal Blocks EM.0 Centers; Modular Rating: A, 00V Center Spacing: 0. (.0mm) Wire Range: #1- AWG Housing Material: Black Polyamide Type /, V0 Screw Size: M.0 Chromate Steel Operating
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationData sheet. W-Series WDU 2.5 RT
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationDPC F - P3-24. Part Number Scheme. Dimensions
Description Definite Purpose Contactor Definite Purpose contactors are electrically operated switching devices specifically designed for the heating, ventilation, air conditioning, heat pump and refrigeration
More informationUL Listed power distribution blocks
Technical ata 10537 ffective September 2017 Supersedes ugust 2016 atalog number example: P323-3 is a 3-pole P323 Where: The prefix P323 defines the block s lineside characteristics (i.e., one conductor
More informationACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:
ACCESSORIES HN RELAYS (Sockets and DIN rail s) TYPES Type No. of poles Item Part No. PC board DIN rail Standard packing: Carton: 0 pcs.; Case: 00 pcs. Note: Certified by UL/C-UL -pole HN PC board AHNA3
More informationFrom dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).
121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and
More informationDatenblatt. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationDistribution Blocks, Power Blocks, Power Terminals
Distribution Blocks, Power Blocks, Power Terminals Single Pole Distribution Blocks...3-8 Power Solar Blocks...7-8 Two and Four Pole Distibution Blocks...9-13 Power Blocks & Terminals... 14-19 Power Terminals...20-25
More informationlif flex CirCUit ConneCtor 2.54mm [.100"] CeNTerliNe 1.25mm [.049"] CeNTerliNe 1.00mm [.
dam Technologies, Inc. INTRODUTION: dam Tech P Dual Series Port D-Sub Flexible onnectors Printed ircuit provide (FP) the and means Flexible to increase Flat able I/O (FF) without connectors utilizing are
More informationboth pin and sleeve contacts.
The different modules are inserted into the appropriate retaining frames (which vary according to the different housing sizes). There they snap in easily and safely. A special removal tool ensures quick
More informationData sheet. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet. W-Series WDU 4 BL
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationConnecting the Power of the Sun. DC Disconnects for Solar Photovoltaic Installations. DC disconnects for. solar photovoltaic installations
Connecting the Power of the Sun DC Disconnects for Solar Photovoltaic Installations DC disconnects for solar photovoltaic installations Solar energy is heating up Interest in renewable energy sources has
More informationData sheet... W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationENGINEERING CATALOG March, 2008
ENGINEERING CATALOG March, 008 What s New: Flexible Stranded Wire UL Rating Information SCCR with Fuses or Circuit Breakers Datasheets on www.marathonsp.com FUSE HOLDERS POWER BLOCKS TERMINAL BLOCKS CUSTOM
More informationGeneral characteristics and technical data Series VarioPro Basic
General characteristics and technical data Series VarioPro Basic Series Electrical values Operating voltage (DC) Test voltage (DC) 8 kv 12 kv Housing HV- 1-2 Insulation material Flammability class POM
More informationSensorLex 8B Isolated Analog Signal Conditioning Products. and D power. 7 to 34VDC 36V TVS, 1A Fuse, OV detection 35.5V max 6.
Accessories for 8B Analog Modules Features Single Channel DIN Rail Mounting Accessory 2-, 4-, 8-, 16-Position Backpanels Panel or DIN Rail Mounting Options 19-Inch Mounting Rack for Backpanels Interface
More informationConflicts Note: Drop-in Bed liner
Toyota Tundra 2015 LED Bed Lights Preparation Part Number: 00016-34089 Accessory Code: BU1000 Conflicts Note: Drop-in Bed liner Kit Contents Item # Quantity Reqd. Description 1 1 Hardware Kit 2 1 Driver
More informationRelays and associated toroids
Relays and associated toroids Residual-current protection relay Multi 9 format (DIN rail mount) E92034 E92035 E92036 RH10M. RH21M. RH99M. Multi 9 format (with mounting accessories (1) ) E90249 E90251 E90253
More informationSP4040 Series 3.3V 75A Rail Clamp Array
3.3V 7A Rail Clamp Array RoHS Pb GREEN Description The SP4040 provides overvoltage protection for applications such as 0/00/000 Base-T Ethernet and T3/ E3 interfaces. This device has a low capacitance
More information4mm Surface Mount, Single-Turn, Sealed Cermet Trimmers
Effective Date April 5 TOCOS POTENTIOMETERS 4mm Surface Mount, Single-Turn, Sealed Cermet Trimmers RoHS Compliant IMPROVED DESIGN Pb-Free and Cd-Free Features 4mm square SMD, single-turn, sealed cermet
More informationSURFACE MOUNT SILICON RECTIFIER. VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.0 Ampere SYMBOL V RRM V RMS V DC I O I R IFSM. I 2 t
SURFACE MOUNT SILICON RECTIFIER VOLTAGE RANGE 5 to 1 Volts CURRENT Ampere SA1 THRU SA7 FEATURES * Ideal for surface mounted applications * Low leakage current *Metallurgically bonded construction *Mounting
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationDatenblatt. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More information20 Series Power Relays
Power Relays 0 Technical Data... Specification... Model Number Structure - Power Relays...3 Model Number Selection... - 7 Accessories... Mounting Clips... Electrical Characteristics... Dimensions... Instructions...3
More informationGeneral Specifications
General Specifications Electrical apacity (Resistive Load) Power Level: 6A @ 25V A & 3A @ 250V A or 6A @ 30V Other Ratings ontact Resistance: Insulation Resistance: ielectric Strength: Mechanical Life:
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationEP METAL TYPE - SOLDER ISO ASSEMBLY OF EP MALE ISO ASSEMBLY OF EP FEMALE
EP METAL TYPE - SOLDER The EP Series has set the standard in high performance speaker connectors. Apart from its durability and strength, it offers consistent superior power handling capabilities. Features:
More informationSystem Components and Accessories
OutBack Panel Mount Breakers Panel mounted hydraulic-magnetic type breakers that can be used for DC sources, inverters or load circuits. Model Current Voltage Branch Terminals Width Rating Rating Circuit
More informationInstallation requirements
Installation requirements for SUNNY CENTRAL 500U 1 Contents This document describes the requirements which have to be observed for the installation site of the Sunny Central 500U. The installation and
More informationMODEL: M2MNV MODEL: M2MNV-[1][2]-[3][4]
MODEL: MMNV Super-mini Signal Conditioners Mini-M Series ANALOG SWITCHING MODULE Functions & Features Switches between two analog signal channels Switches/Distributes one voltage signal to two channels
More informationTo be automatically connected to the nearest North American Technical Sales Office:
DIN-A-MITE C SCR Power Controller Delivers Up To 80 Amperes in a Compact Package TOTAL CUSTOMER SATISFACTION 3 Year Warranty The Watlow DIN-A-MITE Style C silicon controlled rectifier (SCR) power controller
More informationHARTING Han GND. People Power Partnership
98 42 937 0201 HARTING Han GND People Power Partnership Han GND - Mateable Potential Equalization The new Han GND series now enables pluggable grounding systems Han GND (Han Ground) is the innovative HARTING
More informationRelays. Switching & Controls.
Switching & Controls Selection Guide... 0 General Purpose Relays... RVH Series mm Interface Relays... RVS Series mm Interface Relays... RVH Series mm Interface Relays... RJ Series Slim Power Relays...
More informationQJxx16xHx Series. Thyristors 16 Amp High Temperature Alternistor Triacs. RoHS. Description
RoHS Description This 16A high temperature alternistor triac solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls,
More informationOutline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions
www.we-llc.com Outline Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions Bonding & Grounding Grounding Terms Equipment Grounding: The National Electrical
More informationThyristors 12 Amp Alternistor (High Communitation) Triacs
Qxx12xHx Series RoHS Description This 12 Amp bidirectional solid state switch series is designed for AC switching and phase control applications such as motor speed and temperature modulation controls,
More informationTSB Suffix Suffix. 503Si 2 Suffix
Catalog Numbering Code Europa locks TS 230 02 Suffix Suffix Series Europa locks Options (blank) = Standard (105 ) HT = High Temperature (150 ) US = 600V Pitch 230 = 8mm 500 = 10mm 500SK = 10mm, Elongated
More information0.80mm SUB-MICRO HEADERS 1.00mm MICRO HEADERS
dam Technologies, Inc. 0.80mm SU-MIRO HRS 1.00mm MIRO HRS.031" [0.80] & " NTRLIN MPH & SPH / MRS & SRS INTROUTION: dam Tech 0.8mm and 1.00mm and Female Header series is a fine pitch, low profile, dual
More informationMINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Amps. SQUARE BODY Square body fuses for semiconductor
TABLE OF CONTENTS MINIATURE DIAZED NEOZED CYLINDER Mini fuses in five sizes to 20 Slow Blow Medium Blow Fast Blow Super Fast Blow "Bottle" fuses in five sizes to 200 gl/gg - Slow Blow - Fast Blow Compact
More informationSEALED, ILLUMINATED ROCKER SWITCHES
K/K LOW OST, ROKER FOR WET & DUSTY ENVIRONMENTS The K series rockers are rugged, high performance sealed switches designed for use under severe conditions found in marine, appliance, heavy equipment and
More information* Low cost * Low leakage * Low forward voltage drop * High current capability DO-15 R2500F R3000F R4000F R5000F VRRM VRMS VDC IFSM. I 2 t 3.
HIGH VOLTAGE FAST RECOVER RECTIFIER R25F THRU R5F VOLTAGE RANGE 25 to 5 CURRENT.2 Ampere FEATURES * Low cost * Low leakage * Low forward voltage drop * High current capability DO-15 MECHANICAL DATA * Case:
More informationHeavy Duty Safety Switches
eavy uty Safety Switches 240 Volt Class 110 Visible blade heavy duty safety switches are designed for application where maximum performance and continuity of service are required. All heavy duty safety
More informationSolid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..
Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K.. 1-pole AC solid state relays Soft start switching for short wave infrared heaters Rated operational voltage: up to 660 VAC Rated operational
More informationGT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC
TY Series TY Series ON Delay Key features of the TY series include: PDT, 3A or DPDT, A contacts time ranges Repeat error ±0.2% maximum Control settings by hand or screwdriver Power ON and timing out LED
More informationMAGNUM. Terminal Blocks / Power Distribution Blocks / Interconnect Devices
MAGNUM Terminal Blocks / Power Distribution Blocks / Interconnect Devices MAGNUM, formerly known as Bussmann Circuit Components, is a product family of Cooper Bussmann. MAGNUM manufactures the most complete
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationDatasheet. W-series terminal with clamping yoke connection WDU 16
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationRelays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.
RFV Key features: Compact and EN compliant RFV force guided relays Force guided contact mechanism (EN00 Type A TÜV approved) Contact configuration -pole (NO-NC, 3NO-NC) 6-pole (NO-NC, NO-NC, 3NO-3NC) Built-in
More informationThis Chapter contains:
7 This Chapter contains: Table 7.1 Table 7-2 Table 7-3 Table 7-4 contains the general technical specifications for the MICROMASTER 430 inverter contains terminal tightening torques and the required cooling
More informationPoke-Home: Horizontal AWG: WTB INTER CONNECT APPLICATIONS FEATURES AND BENEFITS ELECTRICAL MECHANICAL ENVIRONMENTAL HOW TO ORDER 00X
The new 9276 series connector provides a quick and reliable wire-toboard termination in a sleek 2.5mm pitch SMT package for a broad range of industrial and commercial markets. With almost every product
More informationData sheet C6 A RJ45 field plug pro 360
Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable variable
More informationPOWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 )
POWER CAGE CLAMP High-Current Terminal Blocks for Conductors up to 350 kcmil (185 mm 2 ) vibration-proof fast maintenance-free WAGO BENEFITS Using springs instead of screws is the key to WAGO s success.
More informationData sheet C6 A RJ45 field plug pro
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable
More informationC-Series. Circuit Breaker.
-Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in
More informationPower-IO
E Family of Solid State Relays Up to 900 VDC switched 12-20 khz, FAST switching times for superior PWM performance Ultra Cool Technology trademarked thermal management design Green LED that indicates input
More informationLedex Low Profile Linear Solenoids
Ledex Low Profile Linear Solenoids 8. (55.9) 6. (66.9). (77.9). (89.) % Duty Cycle W 5% Duty Cycle 8W 5% Duty Cycle 6W % Duty Cycle W Ledex Low Profile Solenoids Linear actuation Space-saving, low-profile
More informationNEMA Size 1 Cat. No. CN55DN3AB
-80 Contactors and Contents Description Product Family Overview Page Product Description....... -78 Features................ -78 Standards and Certifications........... -78 Selection.............. -79
More informationSELECTION GUIDE. BULLETIN 156 Solid-State Contactors
SELECTION GUIDE BULLETIN 156 Product Overview/Product Selection Bulletin 156 The Bulletin 156 are ideal replacements for electro-mechanical contactors where fast and demanding switching of loads such
More informationTV-15, 30 AMP (1 Form A) Power Relay
VDE TV-, 3 AMP ( Form A) Power Relay RELAYS Form A Plug-in type Form A type also available with 48A contact capacity FEATURES. Excellent resistance to contact welding Owing to the pre-tension and kick-off
More informationILA2E572PC1A0 integrated drive ILA with servo motor V - EtherCAT - indus connector
Characteristics integrated drive ILA with servo motor - 24..48 V - EtherCAT - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network
More informationTERMINAL BLOCKS BARRIER
See More Online From 440+ Top Brands. BARRIER FLEXI-BLOCK CUT-AWAY TERMINAL BLOCK SYSTEM TRI-BARRIER FLEXI-BLOCK FLEXI-BLOCK FLEXI-BLOCK End Stop Standard Track Flanged Track Custom-made terminal blocks
More informationFeatures. Samples. Symbol Parameter Value Unit TO-92 SOT-223. t p TO-92 SOT-223. = 2 x I GT. Peak gate current t p. = 10 μs T J
L01 Series RoHS Description New 1 Amp bi-directional solid state switch series offering direct interface to microprocessor drivers in economical TO-92 and surface mount packages. The die voltage blocking
More informationTeccor brand Thyristors 40 Amp Low T q SCR. Symbol Parameter Test Conditions Value Unit RMS on-state current T C = 100 C 40 A I T(AV)
RoHS Description The S4040xQx series of s offer fast turn-off time (tq) characteristics required for applications such as power inverters, switching regulator, and high frequency pulse circuits. These
More informationData sheet C5 RJ45 field plug pro 2P PROFINET
Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port
More informationTeccor brand Thyristors EV Series 0.8 Amp Sensitive Triacs
LX8 Series RoHS Description New 0.8 Amp bi-directional solid state switch series offering direct interface to microprocessor drivers in economical TO-92 and surface mount packages. The die voltage blocking
More informationMJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400
Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in
More informationM = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent
ulletin 800T 30.5 mm Push uttons 2-Position Knob/Lever Type Selector Switch Units, Illuminated Operator Position Operator Type Standard Knob Knob Lever Type Lamp Volts olor M = Maintained S = Spring Return
More informationTMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.
TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins
More informationMain catalogue. SNK Series Terminal Blocks Accessories Marking Solutions
Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions 10 5.2 mm m 0.205 in spacing 53 2.09" 26.7 1.05" 3 4 5 6 7 8 9 10 Save space by connecting s up to 4 mm2 (CB certified) 12 AWG in
More information3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays
.6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60
More informationTeccor brand Thyristors 16 Amp Standard SCR V DRM. Symbol Parameter Test Conditions Value Unit V DSM
16 mp Standard SCR RoHS Description The Littelfuse SCR S8016x series are specifically designed for Electric Vehicle On-Board Charger (EVOBC) applications. This SCR C line input rectifier can handle Level
More information.093 [2.36] Commercial Pin and Socket Connectors
.09 [.] Commercial Product Facts Polarized Cavity identification Low contact-mating force Dual locking lances Detent and positive locking Contacts available in brass and phosphor bronze with tin and gold
More informationRelated Products SDP Series SFL Series SCP Series SCL Series SDU UPS
4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility
More informationSamples. Symbol Parameter Test Conditions Value Unit RMS on-state current T C = 100 C 40 A I T(AV) Average on-state current T C
Sxx40x Series RoHS Description Excellent unidirectional switches for phase control applications such as heating and motor speed controls. Standard phase control SCRs are triggered with few milliamperes
More information400 Va.c., 500 Va.c., 690 V a.c. Rated current I n. 120 ka
Low voltage NV/NH knife-blade fuse-links Electrical characteristics Rated voltage U n 00 Va.c., 500 Va.c., 90 V a.c. Rated current I n - 0 A Breaking capacity at 1,1 U n ka Fusing characteristics gg, am,
More informationAMPOWER Terminals and Splices Catalog Revised 05-95
atalog 805 Product Facts Designed for large cables and leads Ideally suited for power generation and distribution Accepts a wide range of stranded copper wires (6 AWG to 000 MM [3-507 mm ] for terminals
More informationThe World of Motion Control
PWB-Ruhlatec Industrieprodukte GmbH Siegburger Str. 39a 53757 Sankt Augustin Germany www.pwb-technologies.com info@pwb-technologies.com AE30 medium temperature range LD 1 of 9 Rev. 3.0 / 06.07.2007 Description
More informationENVIRONMENTAL. Operating Temperature: -40ºC to +125ºC 0XX. Contact Size. Contact Wire Max Size Gauge Insulation mm Contact
The Industrial and Solid State Lighting markets continue to look for new products which will reduce size and cost without jeopardizing performance. The new dual-beam boxed contact system from AVX surface
More informationOPTITEMP TT 20 Technical Datasheet
OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationData sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/
Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port
More informationisolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems
T M 1 isolr275 / AGH-LR Digital Ground Fault Monitor / Ground Detector For Low-Resistance Ungrounded (Floating) AC/DC Systems Technical Bulletin NAE1012110 / 12.2011 isolr275 / AGH-LR Ground Fault Monitor
More informationAMP Power Lock Connectors
Product Facts High current handling capability: 31 or 53 amperes maximum depending on application (reference product specs) Modular housings for multiple connector applications Assortment of mounting accessories
More informationPower Supplies 3. SDN-C Compact DIN Rail Series
SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs
More information