LF SERIES CLASS R & H/K5 FUSE BLOCKS
|
|
- Roger Townsend
- 5 years ago
- Views:
Transcription
1 250 V 00 V Specifications Description The Littelfuse Class R and H/K5 blocks offer many benefits such as indication, snap-to-release DIN rail mounting and universal mounting holes. Class H and Class R fuse blocks are dimensionally the same, but Class R blocks incorporate a rejection feature, which only allows Class R fuses to be inserted. Features/Benefits Universal mounting holes for easy replacement Indication offered on most 250 V and 00 V versions One hand release from DIN rail for ferrule style fuses Reinforced fuse clips are standard on all Class H and Class R fuse blocks Covers available for A and lower to enhance safety Web Resources Download CAD drawings, fuse block cover datasheet and other technical information: littelfuse.com/lfr littelfuse.com/lfh Voltage Rating 250 V, 00 V Ampere Ratings 0-00 A Leakage Current <0. ma at 00 V Withstand Rating Class H: 10 ka RMS SYM Class R: ka RMS SYM Flammability Rating UL94 V-0 Approvals UL Listed (File: E14721) CSA Certified (File: LR731) Environmental RoHS Compliant, Lead (Pb) Free Recommended Fuses 250 Class R Blocks LLNRK KLNR FLNR/FLNR_ID V Class H / K5 Blocks NLN V Class R Blocks LLSRK/LLSRK_ID KLSR IDSR... 1 FLSR/FLSR_ID V Class H / K5 Blocks NLS Ordering Information (Class H 250 V) 0 00 ORDERING COVER DIN PART E TEMP ORDERING BOX PRES SURE RAIL * 1 LFH2501 C P S C -14 AWG 2 LFH2502 C P S 2.8 N-m (25 in-lbs) P AWG CU Only 125 C LFH250FBC 3 LFH2503 C P S S AWG 1 LFH25001 CID 5. N-m (50 in-lbs) 2-4 AWG 2 LFH25002 CID CU-AL 125 C LFH2500FBC 3 LFH25003 CID 2.8 N-m (25 in-lbs) -14 AWG 1 LFH251 CID 13. N-m (120 in-lbs) 2/0- AWG Solid/ 4.5 N-m (40 in-lbs) 8 AWG CU-AL 1 C LFH25FBC 3 LFH253 CID Stranded 4.0 N-m (35 in-lbs) AWG 1 LFH251 C 31.1 N-m (275 in-lbs) 250 kcmil- CU-AL 1 C 3 LFH253 C 1 LFH251 C 31.1 N-m (275 in-lbs) (2) 350 kcmil-1/0 CU-AL 1 C 3 LFH253 C 1 LFH25001 C 42.4 N-m (375 in-lbs) (2) 500 kcmil-4 CU-AL 1 C 3 LFH25003 C Note: Reinforcing springs standard on all Class H fuse blocks. *Covers sold individually. One cover needed for each pole Littelfuse POWR-GARD Products Catalog
2 Ordering Information (Class H 00 V) 0 00 ORDERING ORDERING BOX PRES SURE 1 LFH001 CID PID SID C -14 AWG 2 LFH002 CID PID SID 2.8 N-m (25 in-lbs) P AWG 3 LFH003 CID PID SID S AWG 1 LFH0001 CID 5. N-m (50 in-lbs) 2-4 AWG 2 LFH0002 CID 3 LFH0003 CID 2.8 N-m (25 in-lbs) -14AWG 1 LFH01 CID 13. N-m (120 in-lbs) 2/0-AWG 4.5 N-m (40 in-lbs) 8 AWG 3 LFH03 CID 4.0 N-m (35 in-lbs) AWG 1 LFH01 C 3 LFH03 C 1 LFH01 C 3 LFH03 C 1 LFH0001 C 3 LFH0003 C Note: Reinforcing springs standard on all Class H fuse blocks. Ordering Information (Class R 250 V) 0 00 Note: Reinforcing springs standard on all Class R fuse blocks. Note: Reinforcing springs standard on all Class R fuse blocks. *Covers sold individually. One cover needed for each pole Littelfuse POWR-GARD Products Catalog 89 E CU Only TEMP SNAP TO RELEASE COVER ORDERING * 1 C LFH00FBC CU-AL 1 C LFH000FBC Solid/ CU-AL 1 C LFH0FBC Stranded 31.1 N-m (275 in-lbs) 250 kcmil- CU-AL 1 C 31.1 N-m (275 in-lbs) (2) 350 kcmil-1/0 CU-AL 1 C 42.4 N-m (375 in-lbs) (2) 500 kcmil-4 CU-AL 1 C ORDERING SNAP COVER E TEMP TO ORDERING ORDERING BOX PRES SURE RELEASE * 1 LFR2501 C P S C -14 AWG 2 LFR2502 C P S 2.8 N-m (25 in-lbs) P AWG CU Only 125 C LFH250FBC 3 LFR2503 C P S S AWG 1 LFR25001 CID 5. N-m (50 in-lbs) 2-4 AWG 2 LFR25002 CID CU-AL 125 C LFH2500FBC 3 LFR25003 CID 2.8 N-m (25 in-lbs) -14 AWG 1 LFR251 CID 13. N-m (120 in-lbs) 2/0- AWG Solid/ 4.5 N-m (40 in-lbs) 8 AWG CU-AL 3 LFR253 CID Stranded 4.0 N-m (35 in-lbs) AWG 1 C LFH25FBC 1 LFR251 C 3 LFR253 C 31.1 N-m (275 in-lbs) 250 kcmil- CU-AL 1 C 1 LFR251 C 3 LFR253 C 31.1 N-m (275 in-lbs) (2) 350 kcmil-1/0 CU-AL 1 C 1 LFR25001 C 3 LFR25003 C 42.4 N-m (375 in-lbs) (2) 500 kcmil-4 CU-AL 1 C Ordering Information (Class R 00 V) 0 00 ORDERING SNAP COVER E TEMP TO ORDERING ORDERING BOX PRES SURE RELEASE * 1 LFR001 CID PID SID C -14 AWG 2 LFR002 CID PID SID 2.8 N-m (25 in-lbs) P AWG CU Only 1 C LFH00FBC 3 LFR003 CID PID SID S AWG 1 LFR0001 CID 5. N-m (50 in-lbs) 2-4 AWG 2 LFR0002 CID CU-AL 1 C LFH000FBC 3 LFR0003 CID 2.8 N-m (25 in-lbs) -14 AWG 1 LFR01 CID 13. N-m (120 in-lbs) 2/0- AWG Solid/ 4.5 N-m (40 in-lbs) 8 AWG CU-AL 3 LFR03 CID Stranded 4.0 N-m (35 in-lbs) AWG 1 C LFH0FBC 1 LFR01 C 3 LFR03 C 31.1 N-m (275 in-lbs) 250 kcmil- CU-AL 1 C 1 LFR01 C 3 LFR03 C 31.1 N-m (275 in-lbs) (2) 350 kcmil-1/0 CU-AL 1 C 1 LFR0001 C 3 LFR0003 C 42.4 N-m (375 in-lbs) (2) 500 kcmil-4 CU-AL 1 C
3 28. [1.13] 250 V A 15. [.1] 13.0 [.51] 4.8 [.19] 7.5 [3.01] 74.7 [2.94] 48.5 [1.91] 32.2 [1.27] 23.8 [.94] 1.3 [.4].8 [.27] 42.9 [1.9] 31.8 [1.25] 40.1 [1.58] 8.4 [.33] 5. [.22] [1.2] [1.51] 44. [1.7] R2.8 [.11] R2.8 [.11].2 THRU 3. [.14] 250 V 0 A 37.3 [1.47] 22.4 [.88] 14.8 [.58] 9.7 [.38] 57.4 [2.2] [4.10] 70.7 [2.78] 24.9 [.98] 89.2 [3.51] 55.8 [2.20] 7.5 [3.01] 43.1 [1.70] 43.9 [1.73] 75.7 [2.98] [4.71] R2.8 [.11] 5.5 [.21] 12.3 [4.97] 250 V A. [3.9] 4.0 [1.81] 91. [3.1] 34.7 [1.37] 20.3 [.80] 11.3 [.45] 53. [2.11] 72. [2.8] 0.5 [2.38] 51.5 [2.03].0 [2.0] 22.9 [.90] [5.23] [7.00] 90
4 250 V A 3.5 [2.50] 7.2 [3.00] 228. [9.00] [8.50] [7.25] 15.1 [.50] 3.5 [2.50] 19.1 [.75] 52. [2.07] 72.4 [2.85] R4.3 [.17] [5.0] [7.13] 250 V A.7 [2.3] 22.2 [.88] 88.9 [3.50] 84.4 [3.32] [9.88] 95.3 [3.75] [4.25] 2.7 [10.50] 95.3 [3.75] 19.9 [7.75] [7.25] [12.5] [4.5] 79.4 [3.1] 34.9 [1.4] 19.1 [.8] 250 V 00 A 19.1 [.8] [4.5] [5.5] [11.50] 110. [4.4] [11.8] 15.9 [.] [4.5] Ø..4 Ø [9.5] [8.5] 355. [14.0] 91
5 38.4 [1.51] 21.5 [.85] 19.2 [.7] 1.8 [.].4 [.25] 00 V A 73.1 [2.88] 52.5 [2.07] [4.25] 8.4 [3.40] 75.9 [2.99] 51. [2.03] 41.1 [1.2] 20.7 [.82] 47. [1.87] R2. [.10] 5.0 [2.20] 118. [4.7] [5.00] 1.7 [.5] 00 V 0 A 43.8 [1.73] 83. [3.29] 32.4 [1.28] 29.8 [1.17] 19.9 [.78] 11.4 [.45] 9.5 [2.74] [4.85] [4.] 59. [2.35] 59.7 [2.35] 99.4 [3.91] 22.9 [.90] [2.18] [2.92].2 THRU [5.] [7.25] 00 V A 33.8 [1.33] 19. [.77] 15.0 [.59] [5.72] [4.95] [4.21] 79.8 [3.14] 1.0 [2.40] 53.4 [2.10].0 [2.0] 22.9 [.90] 4. [2.54] [.80] 228. [9.00] 92
6 00 V A 3.5 [2.50] 44.5 [1.75] 31.8 [1.25] 7.2 [3.00] 3.5 [2.50] 52.3 [2.0] 84.2 [3.32] Ø [.31] 228. [9.00] 19.9 [7.75] 15.1 [.50] 72.4 [2.85] 15.9 [.3] 52.3 [2.0] 7.7 [3.02] 84.1 [3.31] 10.3 [.31] [7.5] [9.2] R4.3 [.17] [3.50] 73.0 [2.88].7 [2.3] 22.2 [.88] 00 V A 95.3 [3.75] 14.1 [5.75] 2.7 [10.50] [9.88] 84.4 [3.32] [8.75] [10.75] 38.3 [14.50] [4.50] 95.3 [3.75] 79.4 [3.13] 34.9 [1.38] 19.1 [.75] 00 V 00 A [4.50] [7.00] [10.00] 19.1 [.75] [12.50] [11.75] 110. [4.3] Ø [17.00] 93
Specifications. Class R Blocks 250 V FLNR/FLNR_ID KLNR LLNRK TLN. Torque N-m (120 in-lbs) 2/0-6 AWG
LF Series lass H/K5 AND R Fuse Blocks Specifications Voltage : 250 V, 600 V Ampere s: 0 600 A Leakage urrent:
More informationCLASS H/K5 AND R SERIES FUSEBLOCKS
LASS H/K5 AND R SERIES FUSEBLOKS lip designs maximize electrical contact and minimize heat rise Standard reinforcing clips on all lass R fuseblocks and lass H fuseblocks rated 00 A and higher RoHS compliant,
More informationonlinecomponents.com
Short-Circuit Current Ratings and Feeder Spacing SCCR Information: Power Distribution Blocks with SCCR and Feeder Spacing The requirements of the National Electric Code (NEC) and UL508A now require many
More informationPower Distribution Blocks with Short-Circuit Current Ratings
Power Distribution Blocks with Short-Circuit Current Ratings General Information: The requirements of the 005 National Electric Code (NEC) and UL508A now require many electrical panels to carry a Short
More informationTable of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance
Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8
More informationIncandescent Lampholders: Edison Screw and Bayonet Cap
: Edison Screw and Bayonet Cap Table of Contents E14 22.223 22.230 E12 22.228 22.231 [08]..10 E17 E27 22.317 [08] 12 22.318 [08] 12, 13 2010-2012 This page is only valid in connection with the general
More informationSectional Terminal Blocks
General Information: Sectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the block producing the required
More information8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution
Terminal Blocks, Fuse Blocks and Fuse Holders.3 CHDB Series Blocks, Enclosed and Open CHDB Series Blocks Product Description Features and Benefits Eaton s CHDB Series of Blocks was designed for high short
More informationTable of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance
Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationDatasheet WPDB Power Distribution Blocks
Datasheet WPDB Power Distribution Blocks Now you can manage multiple load connections and a wide range of wire sizes with Weidmuller s Power Distribution blocks. By using the best materials and the best
More informationData sheet. W-Series WDU 2.5 RT
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationDistribution Blocks, Power Blocks, Power Terminals
Distribution Blocks, Power Blocks, Power Terminals Single Pole Distribution Blocks...3-8 Power Solar Blocks...7-8 Two and Four Pole Distibution Blocks...9-13 Power Blocks & Terminals... 14-19 Power Terminals...20-25
More informationSectional Terminal Blocks
ectional Terminal locks General Information: ectionals are terminal blocks which are made up of individually molded units with electrically conductive members which, when assembled together, make up the
More informationENGINEERING CATALOG March, 2008
ENGINEERING CATALOG March, 008 What s New: Flexible Stranded Wire UL Rating Information SCCR with Fuses or Circuit Breakers Datasheets on www.marathonsp.com FUSE HOLDERS POWER BLOCKS TERMINAL BLOCKS CUSTOM
More informationDatenblatt. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet. W-Series WDU 4 BL
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationData sheet... W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationSuccess Depends on the Crimp
Success Depends on the Crimp Understanding the UL-486F Standard for Bare and Covered Ferrules Vince Barone, May 12, 2015 1 Agenda 2 What is a Ferrule? Ferrules are terminals that only have a barrel. They
More informationData sheet. W-Series WDU 2.5
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationDatenblatt. W-Series WDU 10
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More informationElectronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact
Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic
More informationRelays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:
RU Series Universal Relays Key features: Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator
More informationElectronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationKRPA, KRP, KA, KR series
Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting
More informationGeneral characteristics and technical data Series VarioPro Basic
General characteristics and technical data Series VarioPro Basic Series Electrical values Operating voltage (DC) Test voltage (DC) 8 kv 12 kv Housing HV- 1-2 Insulation material Flammability class POM
More informationThree-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41
Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.
More informationThree-phase monitoring relays CM-PVS.81
Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is
More informationYL CONNECTOR. 1Certified LR R Specifications. Standards. 4.5mm pitch/disconnectable Crimp style Wire-to-wire connectors
.mm pitch/disconnectable Crimp style Wire-to-wire connectors Panel lock Inner lock lance Specifications Current rating: 0A AC, DC max. (A when retainers are mounted) Voltage rating: 00V AC, DC max. Temperature
More informationMULTI CONNECTION SYSTEM. Product Overview
MULTI CONNECTION SYSTEM Product Overview THE ENTIRE RANGE OF MCS CONNECTORS MICRO Pin spacing: 2. mm Conductor sizes: 0.08 0. mm 2 (28 20 AWG) The Most Compact MCS MICRO Connector System with CAGE CLAMP
More informationEP METAL TYPE - SOLDER ISO ASSEMBLY OF EP MALE ISO ASSEMBLY OF EP FEMALE
EP METAL TYPE - SOLDER The EP Series has set the standard in high performance speaker connectors. Apart from its durability and strength, it offers consistent superior power handling capabilities. Features:
More informationHigh-current terminal block - UKH
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More information- 1 - General ordering data Order No
General ordering data Order No. 1752992001 Part designation SL-SMT3.5/3/180G 1.5SN Version EAN 4032248130917 Qty. 100 pc(s). PCB plug-in connector, Male connectors, Reflow solder connection, Pitch: 3.50
More informationDISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS
DISTRIBUTION BLOCKS POWER BLOCKS POWER TERMINALS 3-8 Single Pole Distribution Blocks 7-8 Power Solar Blocks 9-13 Two and Four Pole Distibution Blocks 14-19 Power Blocks & Terminals 20-25 Power Terminals
More informationSemiconductor contactors, Solid-state relays
Semiconductor contactors, Solid-state relays Content Benefits and advantages, approvals... 224 R100.xx semiconductor contactors, single-phase Ordering details... 225 Technical data... 228 Dimensional drawings...
More informationDatasheet. W-series terminal with clamping yoke connection WDU 16
The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality
More information3M Scotchlok Insulated Electrical Spring Connector B (Blue)
3M Scotchlok Insulated Electrical Spring Connector B (Blue) Data Sheet November 2008 Application Use 3M Scotchlok Insulated Electrical Spring Connector B (Blue) to electrically connect two or more conductor
More informationSelect G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges
NO: RL-159 PRODUCT: G3PA SSRs, G32A Cartridges DATE: January 2017 TYPE: Partial Discontinuation Notice Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationSINGLE POLE SOCKETS - SOLDER MOUNT
SINGLE POLE SOCKETS - SOLDER MOUNT 450 - XXXX - XX - XX - 00 Body Brass Copper* Spring Beryllium Copper (Heat Treated) Dash Body Spring RoHS -03 Gold over Nickel Gold over Nickel -04 Electro-Tin Electro-Tin
More informationonlinecomponents.com
Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationCoupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC
Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation
More informationSolid State Relays 1-Phase, Soft Start Switching Types RGS1P..K..
Solid State Relays 1-Phase, Soft Start Switching Types RGS1P..K.. 1-pole AC solid state relays Soft start switching for short wave infrared heaters Rated operational voltage: up to 660 VAC Rated operational
More informationRelays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection
RY/RM Series Miniature Relays Key features: RY (A), RY (A), RM (A) General purpose miniature relays A or A contact capacity Wide variety of terminal styles and coil voltages meet a wide range of applications
More informationIndustrial, 2-Pole ZS Type RA2A
Solid State Relays Industrial, 2-Pole ZS Type 2-Pole AC Solid State Relay Zero switching For resistive and inductive AC loads Direct copper bonding (DCB) technology LED indication Rated operational current:
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationElectronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact The CT-AHE is an electronic time relay with OFF-delay. t is from the CT-E range. The CT-E range is the economic range of ABB s time
More informationData sheet C6 A modul K 180 jack - Keystone style
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 180 cable feed solid,
More informationStarting Torque Controller Technical Data
Technical Data Starting Torque Controller Technical Data Bulletin 154 Topic Page Product Overview 2 Catalog Number Explanation 2 Product Selection 3 Specifications 3 Wiring Diagrams 9 Approximate Dimensions
More informationThrough and Ground Conductor Terminal Blocks 290 Series
11 474 Through and Ground Conductor Terminal Blocks 290 Series 0.34-1. mm"f-st" 0.31-1 mm"s" 1 00 V/6 kv/3 2 1 AWG 22-16"f-st" AWG 22-18"s" I N 13. A Terminal block width mm / 0.197 in 0.34-1. mm"f-st"
More informationACCESSORIES. Type No. of poles Item Part No. Performance. Contact arrangement 1 Form C 2 Form C Max. continuous current (Ambient temperature:
ACCESSORIES HN RELAYS (Sockets and DIN rail s) TYPES Type No. of poles Item Part No. PC board DIN rail Standard packing: Carton: 0 pcs.; Case: 00 pcs. Note: Certified by UL/C-UL -pole HN PC board AHNA3
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationSubject to changes 11/2003 Page 1/7
Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationData sheet C6 A RJ45 field plug pro 360
Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable variable
More informationSemiconductor contactors, Solid-state relays
Semiconductor contactors, Solid-state relays Content Benefits and advantages... 338 Approvals and marks... 338 Semiconductor contactors... 339 Ordering details... 339 R100.xx, single-phase... 339 R300.xx,
More informationData sheet C6 A RJ45 field plug pro
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable
More informationMultifunctional three-phase monitoring relays CM-MPS CM-MPS.23
Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage
More informationNZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data
Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000
More informationElectronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact
Data sheet Electronic timer CT-AWE mpulse-off with auxiliary voltage, 1 c/o (SPDT) contact The CT-AWE is an electronic time relay with mpulse-off function. t is from the CT-E range. The CT-E range is the
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More information22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection
Relays 22 Technical Data...1 Specifications...2 Model Number Structure - Relays...3 Model Number Selection... 4-5 Electrical Characteristics...6 Accessories...7 Dimensions...8 Instructions...10 Safety
More informationMain catalogue. SNK Series Terminal Blocks Accessories Marking Solutions
Main catalogue SNK Series Terminal Blocks Accessories Marking Solutions 10 5.2 mm m 0.205 in spacing 53 2.09" 26.7 1.05" 3 4 5 6 7 8 9 10 Save space by connecting s up to 4 mm2 (CB certified) 12 AWG in
More informationData sheet C5 RJ45 field plug pro 2P PROFINET
Illustrations Dimensional drawing Page 1/5 See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port
More informationMultifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72
Data sheet Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 The three-phase monitoring relays CM-MPN.x2 monitor the phase parameters phase sequence, phase failure,
More informationPRODUCT BROCHURE. Ty-Duct wiring duct Wire management made easy
PRODUCT BROCHURE Ty-Duct wiring duct Wire management made easy 2 TY-DUCT WIRING DUCT Overview The versatile configurations you need for routing and concealing wiring ABB s innovative Ty-Duct products offer
More informationDatasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,
More informationTERMINAL BLOCKS BARRIER
See More Online From 440+ Top Brands. BARRIER FLEXI-BLOCK CUT-AWAY TERMINAL BLOCK SYSTEM TRI-BARRIER FLEXI-BLOCK FLEXI-BLOCK FLEXI-BLOCK End Stop Standard Track Flanged Track Custom-made terminal blocks
More informationInsulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC
Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationData sheet C6 A modul K 90 jack - keystone style
Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: Keystone, 90 cable feed solid,
More informationNS..S contactor relays - with spring terminals AC operated
NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed
More informationSLKK 5. Extract from the online catalog. Order No.:
Extract from the online catalog SLKK 5 Order No.: 0461018 Double-level terminal block with protective conductor foot, cross section: 0.2-4 mm², width: 6.2 mm, color: Gray Commercial data EAN 4017918002381
More informationFeed-through terminal block - PT 10-TWIN
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationSemiconductor & Special Protection Protistor Square body NH fuse-links Sizes 000 to 3 ar 500 to 700VAC 16 to 1000A
s to ar 5 to VAC 6 to A The /V Protistor fuse-links provide maximum flexibility in equipment design and ultimate protection for today's power conversion equipment. These NH style fuse-links are defined
More information3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays
.6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60
More informationElectronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationData sheet. C5 RJ45 field plug pro 2P 360 PROFINET. Illustrations P/N 130E405042PE EAN Product specification. Page 1/
Page 1/6 Illustrations Dimensional drawing Wiring See enlarged drawings at the end of document Product specification Cat.5 class D RJ45 plug, 2 pairs, to be assembled in the field fully shielded and multi-port
More informationCompactLogix 5370 L3 Control System
CompactLogix 5370 Controllers CompactLogix 5370 L1 Control System CompactLogix 5370 L2 Control System CompactLogix 5370 L3 Control System CompactLogix 5370 controllers provide scalable controller solutions
More information20 Series Power Relays
Power Relays 0 Technical Data... Specification... Model Number Structure - Power Relays...3 Model Number Selection... - 7 Accessories... Mounting Clips... Electrical Characteristics... Dimensions... Instructions...3
More informationRU Series. Full featured universal miniature relays. Designed with environment taken into consideration.
Universal Series Safety The contact position can be confirmed through the five small windows. Using the latching lever, operation can be checked without energizing the coil. The latching lever is color
More informationMKDS 3/ 4. Extract from the online catalog. Order No.:
Extract from the online catalog MKDS 3/ 4 Order No.: 1711042 PC terminal block, Nominal current: 24 A, Nom. voltage: 400 V, Pitch: 5 mm, Number of positions: 4, Connection method: Screw connection, Mounting:
More informationData sheet C6 A RJ45 field plug pro 360
Illustrations Dimensional drawing Page 1/6 See enlarged drawings at the end of document Product specification Cat.6 A class E A RJ45 plug to be assembled in the field fully shielded and multi-port capable
More information.093 [2.36] Commercial Pin and Socket Connectors
.09 [.] Commercial Product Facts Polarized Cavity identification Low contact-mating force Dual locking lances Detent and positive locking Contacts available in brass and phosphor bronze with tin and gold
More informationInsulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC
Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC
More informationFLEXIBLE POWER & GROUNDING. Braid Solutions
FLEXIBLE POWER & GROUNDING Braid Solutions Flexible Grounding and Power Options One of our signature products, BURNDY Braid Assemblies are an economical and efficient means of protecting electrical equipment
More informationIntroducing IDC SSL Connector
Introducing IDC SSL Connector The IDC SSL connector series are insulation displacement (IDC) SMT and thru-hole wire-to-board connectors designed for quick, tool-less termination of discrete wires onto
More informationOPENETICS. P/N E-DAT Industry RJ45 field plug insert Cat.6A. Specialist Manufacturer Voice Data Security.
Illustrations Dimensional drawing See enlarged drawings at the end of document Product specification Cat.6 class E A plug to be assembled in the field and mounted in IP67 plug housings of variants 1, 4,
More informationFrom dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).
121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and
More informationSolid State Relay. Zero Switching Types RGC Solid State Contactor 'U' Connection. Product Description RGC 1 A 60 A 40 K G U _.
Solid State Relays Zero Switching Types RGC Solid State Contactor 'U' Connection Product Width ranging from 17.5mm up to 70mm Rated Operational voltage: Up to 600VAC Rated Operational current: Up to 85AAC
More information