1 Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH C 1) NZM6B.../ZM6A...- Frame size A IEC Electrical Ratings Rated impulse withstand voltage U imp V Rated operational voltage U e 50/60 Hz V Rated short-circuit making capacity I cm ka Short-circuit interrupting rating I cn I cu IEC/EN test cycle O-t-CO I cs IEC/EN test cycle O-t-CO-t-CO V 50/60 Hz I cu ka I cs ka /415 V 50/60 Hz I cu ka 100/65 100/90 100/90 I cs ka 50/33 50/45 50/45 cos ϕ 0,25 0,25 0, V 50/60 Hz I cu ka cos ϕ 0,3 0,25 0,25 I cs ka cos ϕ 0,5 0,3 0,3 660/690 V 50/60 Hz I cu ka cos ϕ 0,3 0,3 I cs ka 5 5 cos ϕ 0,7 0,7 DC voltage T 15 ms 110 V DC ka V DC ka V DC ka NZMH6-.../ZM6A...-
2 09/099 NZM9-.../ZM9A-...- NZMH9-.../ZM9A NZM12-.../ZM(A) ) General technical data Standards and specifications UL 489, CSA 22.2 No. 5.1 IEC/EN , VDE 0660 Climatic proofing Damp heat, constant to IEC Damp heat, cyclical to IEC Ambient temperature, min./max. C open 25/+55 (lower temperatures enclosed 25/+40 on request) Shock resistance 25 g (shock duration 20 ms) Leistungsschalter, Lasttrennschalter bis 1600 A ,3 0, / /68 0,3 0, ,3 0, ,5 0, ,5 0, Dimension page 09/109 Weights page 14/020 Mounting position 30 Notes 1) Type NZMH4-...-C thermal magnetic devices (16-80 A) are rated as circuit breakers per IEC/EN only. See page 09/... for more information 2) Type NZM circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated versions.
3 Circuit Breakers, 09/100 Molded case circuit breakers NZMH C 1) NZM6B-.../ ZM6A-...- NZMH6-.../ ZM6A-...- NZM9-.../ ZM9A-...- NZMH9-.../ ZM9A-...- NZM12-.../ ZM(A) ) Frame size A Overload trips Bimetal type (directly heated) A Solid state type A Temperature compensation, residual error in the range 25/ +55 C (reference 20 C) %/K Undervoltage trips Pull-in voltage range % U s Dropout voltage range % U s Minimum command time ms Inrush rating AC VA Sealing AC VA Inrush rating DC W Sealing DC W Shunt trips Pull-in voltage range % U s Minimum command time ms Inrush rating AC (50 Hz) VA Sealing AC VA Inrush rating DC (intermittent duty operation) W Switching times Tripping in the event of a short-circuit Minimum command time ms Opening delay ms Total opening delay ms Opening delay with: Shunt trips (100 % of rated coil voltage) ms Undervoltage trips ms NHI, VHI, AHI, RHI auxiliary contacts 3) IEC/EN ratings Rated operational current I e AC V 50 Hz A 6 6 (1) 6 (1) 6 (1) 6 (1) V 50 Hz A 6 6 (1) 6 (1) 6 (1) 6 (1) V 50 Hz A 4 4 (1) 4 (1) 4 (1) 4 (1) 4 DC-13 (L/R 200 ms) 24 V DC A 1 1 (1) 1 (1) 1 (1) 1 (1) 1 60 V DC A (0.4) 0.8 (0.4) 0.8 (0.4) 0.8 (0.4) V DC A (0.2) 0.7 (0.2) 0.7 (0.2) 0.7 (0.2) V DC A (0.1) 0.3 (0.1) 0.3 (0.1) 0.3 (0.1) 0.3 Lifespan, electrical to AC-15 ops to DC-13 ops Short-circuit rating without welding (contacts closed) Fuseless PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 PKZM0-2.5 Fuses A gl UL/CSA Pilot Duty Ratings Type NHI Pilot Duty A600/P600 A600/P600 A600/P600 A600/P600 A600/P600 A600 Type VHI, AHI, RHI C300 C300 C300 C300 A600 Notes: 1) Type NZMH4-...-C thermal-magnetic devices (16-80A) are rated as circuit breaker per IEC/EN only. See page 09/053 for further information 2) Type NZM circuit breakers are UL/CSA only. Consult Moeller Electric for IEC/EN rated version. 3) For IEC/EN ratings, values which appear in brackets apply to VHI, AHI, and RHI contacts. Otherwise values apply to all contacts.
4 09/101 UL/CSA Motor disconnect switches with IEC/EN Molded case circuit breakers 3 pole NZMH4-...-C NZM(H)6(B)/ZM6-...-C NZM(H)9/ZM9-...-C Frame size A Motor disconnect switches with General technical data page 09/098 page 09/098 page 09/098 IEC/EN circuit breaker ratings page 09/098 page 09/098 page 09/098 UL 508 / CSA 22.2 No.14 motor disconnect switches Adjustable range of thermal overload trips A HP ratings HP page 09/053 page 09/062 page 09/072 Auxiliary contacts, voltage trips page 09/100 page 09/100 page 09/100 Circuit Breakers, UL/CSA Motor disconnect switches without IEC/EN switch-disconnectors 3 pole N6-...-C N9-...-C N C N Frame size A Motor disconnect switches without General technical data page 09/098 page 09/098 page 09/098 IEC/EN switch disconnector ratings Rated impulse withstand voltage V Rated short-time withstand current I cw (1s current) ka Lifespan, mechanical ops Max. operating frequency ops./h Lifespan, electrical AC-1 ops x AC-2, AC-3 ops x DC-2, DC-5 ops x UL/508 / CSA 22.2 No. 14 motor disconnect switches HP ratings page 09/053 page 09/062 page 09/072 Auxiliary contacts, voltage trips page 09/100 page 09/100 page 09/100 UL 489 molded case switches page 09/081 Mounting position 1)
5 09/102 Circuit Breakers, Type NZMH4-...-OBI-C NZMH4-...-C NZM(H)6(B)-.../ZM6(A)-...-(C) NZM(H)6(B)-.../ZM6-...-OBI-C current A AWG AWG AWG /0, up to 90A, 60/75 C cable 100A, 60 C cable Nm NZM(H)6(B)-160/ZM6(A)-125-(C) NZM(H)6(B)-160/ZM6-125-OBI-(C) AWG /0, 125A, 60 C cable Type NZM(H)9-.../ZM9(A)-...-(C) NZM(H)9-.../ZM9-...-OBI-C NZM12-.../ZM12(V)(A)-...- current A AWG 8... Kcmil 300 Kcmil conductors: AWG 3/ conductors: Kcmil AWG 2... Nm Type N6-...-C N9-...-C N C current A AWG /0 75 C cable AWG /0 75 C cable AWG 8... Kcmil 300 Kcmil conductors: AWG 3/ conductors: Kcmil AWG 2... Nm AWG 2... Notes: All devices shown above except type NZM are dual rated UL/CSA and IEC/EN. Consult Moeller Electric for IEC/EN conductor cross information.
PKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationBreakcontact,Front. Articleno Deliveryprogramme. Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories
Breakcontact,Front Partno. M22-K01 Articleno. 216378 Deliveryprogramme Product range RMQ-Titan (drilling dimensions 22.5 mm) Basic function Accessories Standard/Approval UL/CSA, IEC Construction size NZM1/2/3/4
More informationType: DILEM 10 G(24VDC) Article No.:
Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationDescription Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA
DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)
More informationDescription Basic devices with positive operation contacts
Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with
More informationDATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection
DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer
More informationDescription Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module
DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA
More informationDATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC
DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product
More informationInstructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.
Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationType: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description
Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals
More informationCatalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009
Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred
More informationType: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description
Type: EASY719 DA RC Article.: 274117 Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC Description 12 digital inputs (4 inputs available as analog inputs) 6 relay outputs LCD display
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationAC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.
Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and
More informationUtilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms
controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationCircuit Breakers FAZ / FAZ6. Installation Products for Industrial Applications
Circuit Breakers FAZ / FAZ6 Installation Products for Industrial Applications Optimum and powerful protection for every application FAZ up to 15 ka IEC/EN 60947-2 up to 10 ka IEC/EN 60898 up to 10 ka UL
More informationTeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X
Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationCharacteristics 5 TeSys k contactors and reversing contactors
90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to
More informationPage 13-2 Page Page 13-7
Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,
More informationIndex. Capacitor Switching - 2 Contactors. Typical Circuit Diagram 2. Auxiliary Contact Blocks 2. Contactors 3. Dimensions 3. Technical Data 4,5,6
Index Index Page Capacitor Switching - 2 Contactors Typical Circuit Diagram 2 Auxiliary Contact Blocks 2 Contactors 3 Dimensions 3 Technical Data 4,5,6 Contactor operation 7 Function 8 Construction 9 Oscillogram
More informationTeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7
Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control
More informationEasy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays
EMR6 EMT6 ETR4 www.eaton.eu Easy measuring, reliable monitoring and flexible planning - the EMR, ETR and EMT relays The measuring and monitoring of industrial applications made simple - with the EMR6 With
More informationBulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide
Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................
More informationTechnical features table for miniature circuit-breakers SH 200 Series
Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin S-C/S-C IEC Safety Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin S-C/S-C IEC Safety Contactors Mechanically linked N.C. auxiliary contacts
More informationMiniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays
Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationControl module CP-A CM
2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,
More informationDatasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL1077/CSA C22.2 No.235 Supplementary Protectors
Datasheet BR & SU Series UL489/CSA C22.2 No.5-02 (Branch rated) Circuit Breakers UL77/CSA C22.2 No.235 Supplementary Protectors NEW Compared to traditional fuse installation, the UL489/CSA C22.2 No.5-02,
More informationXT IEC Power Control Miniature Controls
Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)
More informationApproved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories
Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationContactors and Contactor Assemblies
s for Switching Motors Technical data General data Permissible mounting position The contactors are designed for operation on a vertical mounting surface. C and DC operation S3 3RT14 46 For DC operation
More informationAF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF
ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC
More informationRatings for Switching AC Motors AC-2, AC-3, AC / /
Bulletin -C/-C Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Ie [A] Bulletin -C/-C Compact sizes from kw/ Hp ( A) AC and DC coil control Common accessories for all contactor
More informations s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz
HPL11002EN DILETTiming relays Rated operational current AC-11 230 V 400 V I th I e I e A A A A A Conventional thermal current Time Range Voltage Article No. See price list Std. pack On-delayed Timing functions
More informationThe CWC0 compact contactors are offered as a complete solution for switching and controlling motors.
Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring
More information2010 CA Z-EN
1 Characteristic/rated operational current ranges B/4 63 A; C/0.5 63 A; D/6 40 A; K/0.5-63 A; S/1-40 A; Z/0.5-63 A Switching capacity: 15 ka to IEC/EN 60947-2 B, C, D, K, S, Z characteristic 1-, 1N-, 2-,
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationTechnical Data Accessories MCCBs Ex9M.
Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit
More informationCM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationDILK50-10(230V50HZ,240V60HZ) Catalog No Eaton Catalog No. XTCC050D10F. Application Contactors for power factor correction. mm 1 x (2.
DATASHEET - DILK50-10(230V50HZ,240V60HZ) Contactor for 3ph three-phase capacitors, 50kVAR Part no. DILK50-10(230V50HZ,240V60HZ) Catalog No. 294076 Eaton Catalog No. XTCC050D10F Delivery program Product
More informationVoltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.
2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault
More information11/0 IZM circuit-breakers, IN switch-disconnectors
11/0 IZM circuit-breakers, IN switch-disconnectors Contents IZM circuit-breakers, IN switch-disconnectors 11/1 from 630 A 6300 A Page Description 11/2 Technical overview 11/4 Overview of functions for
More informationFor Immediate Delivery call KMParts.com at (866)
Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors
More informationVoltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages
Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationAT4 Position Switches Complete Units
03/012 03/013 Complete Units Complete units, IP65 Contacts M = Make B = Break f = Safety function by positive opening of contacts to IEC/EN 60 947-5-1 Contact sequence Contact U Closed u Open Zw = Positive
More informationNS..S contactor relays - with spring terminals AC operated
NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed
More informationMULTIBLOC 00.ST8 Size A, 690VAC Bottom Fitting, 1-,2-,4-pole
MULTIBLOC 00.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR The production programme of MULTIBLOC series 00.ST8 comprises NH fuse switch disconnectors for 160A. They are designed for bottom
More informationThree-phase monitoring relays
2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted
More informationABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories
2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable
More informationModeion MOULDED CASE CIRCUIT BREAKERS BL1000S
G MOULDED CASE CIRCUIT BREAKERS BL1000S G BL1000S COMMERCIAL INFORMATION 3P Switching units, withdrawable device...g4 Overcurrent releases...g5 Signalling units...g5 Residual current monitor...h6 Current
More informationType 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs
Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range
More informationABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.
2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6
More informationCircuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You
Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current
More informationFor Immediate Delivery call KMParts.com at (866)
Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description
More informationT e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker
T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion
More informationThree-phase monitoring relays CM-PFE and CM-PFE.2
Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251
More informationIndustrial Controls. Catalog IC SIRIUS. Answers for industry.
Industrial Controls Catalog IC 10 2012 SIRIUS Answers for industry. Contactor Relays Siemens AG 2012 Overview Standards IEC 60947-1, EN 60947-1, IEC 60947--1, EN 60947--1 The 3TH42 and 3TH43 contactor
More informationInstallation / Monitoring Technique
Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems IP 5883 0249633 IP 5883 ND 5018/035 ND 5018/030 According to IEC/EN 62 020, VDE 0663 For AC and
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),
More informationThree-phase monitoring relay CM-PFS
Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available
More informationMoeller Electric Corporation
EMR4-I Current Monitoring Relays 02/0053 EMR4-I1-2-A EMR4-I15-2-A EMR4-I15-2-B Mechanical lifespan operations x10 6 30 30 30 24-h cycle, 55 C, 93 % relative humidty, 96 h Ambient temperature min./max.
More informationNew Products Catalogue 2009 Safety Relays ESR5
www.moeller.net New Products Catalogue 2009 Safety Relays ESR5 u Description Functional safety on machines monitoring with safety relays ESR5 Emergency-stop circuits Monitoring of movable guards with guard
More informationSIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A
The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance
More informationThree-phase monitoring relay CM-PVE
Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012
More informationMULTIBLOC 4a.ST8 Size 4a, 690VAC, 1600A, 690VAC, Design for Bottom Fitting, 1-, 3-pole
MULTIBLOC 4a.ST8 IEC FUSE SWITCH DISCONNECTORS NH FUSE SWITCH DISCONNECTOR FEATURES & BENEFITS Touch protection IP 20 Safe on load connection/disconnection in accordance with IEC 609473 The production
More information190S A N D 2 C A16 C TE
Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations
More informationLC1D12BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationLC1D32BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 24 V DC coil
Characteristics TeSys D contactor - 3P(3 NO) - AC-3 -
More informationProtection components
General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the
More informationControls Contactors and Contactor Assemblies Special Applications
Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for
More informationEN 50178, IEC
Type: DF51 322 1K5 Article No.: 289107 Sales text """Frequency inverter DF51(1,5 kw; 230V) Ordering information Rated voltage U e V Max. rated operational current I e A 7.1 Rated power for motors at 230
More informationTemperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)
Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationLC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil
Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -
More informationABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.
2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationUncompromising Quality: More Reliability for Single-Phase and Three-Phase Supply Networks
Uncompromising Quality: More Reliability for Single-Phase and Three-Phase Supply Networks This is where quality counts twice as much. No wonder, since low-voltage miniature transformers are indispensable
More informationL-Series. AC or DC Miniature Molded Case Circuit Breakers. UL489 Listed Circuit Breakers UL 489 UL 508
UL 489 ANNEX UL 077 UL 077 L-Series AC or DC Miniature Molded Case UL489 Listed Available in AC and DC models DIN Rail Mounted 7.5mm width Thermal Magnetic 40V, 480Y/77V AC, 50/60Hz 5VDC ( pole); 50VDC
More informationCurrent monitoring relays CM-SRS.2 For single-phase AC/DC currents
Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent
More informationVoltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact
More informationThree-phase monitoring relay CM-PBE
Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of
More informationtechnical information
technical information protection devices 192 circuit protection principle 194 circuit breakers characteristics 200 moulded case circuit breakers (MCCB) 205 prospective fault current 208 selectivity and
More informationBlock Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4
/0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors
More informationElectronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S
More information