CP-T range Product group picture

Size: px
Start display at page:

Download "CP-T range Product group picture"

Transcription

1 Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC C09

2 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details / Technical data /5 Technical diagrams, Dimensional drawings /9 Technical diagrams / 2CDC Catalog Electronic Products and Relays 1/1 ABB /2

3 Benefits and advantages Characteristics J Rated output voltages V, V DC J Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust J Rated output currents 5 A, 10 A, A, A J Rated output powers 1 W, 0 W, W, 960 W J Three-phase or two-phase operation (see derating note) J Supply range x V AC ( x 575 V AC, V DC) J Typical efficiency of 9 % J Low power dissipation and low heating J Free convection cooling (no forced cooling with ventilators) J Ambient temperature range during operation C 1) J Open-circuit, overload and short-circuit stable J Integrated input fuse J Redundancy unit CP-A RU offering true redundancy, available as accessory J LEDs for status indication J Signalling contact "1-1" (solid state) for output voltage OK Benefits Signalling output 1 The devices of the CP-T series offer a solid state output for function monitoring and remote diagnostics. Wide input range Wide range input optimized for world-wide applications: The CP-T power supplies can be used in V AC or - V DC supply systems. Adjustable output voltage 2 The CP-T range feature a continuously adjustable output voltage. Thus, they can be optimally adapted to the application, e.g. compensating the voltage drop caused by a long line length. J Approvals / marks (depending on device, partly pending): A, H D, E / a, b 1) W variants: C 1 2 2CDC S0009 2CDC S Circuit diagram 2 Indication of operational states DC ON: green LED green LED output voltage OK 1 DC LOW: red LED output voltage too low single/parallel: sliding switch - adjustment of single or parallel operation Configuration of single or parallel operation Signalling contact OUTPUT 1-1: terminals - signalling contact A solid-state output indicates the error-free operation of the output voltage. OUTPUT L+, L+, L-, L-: terminals - output 7 INPUT L1, L2, L, PE: terminals - input / ABB Catalog Electronic Products and Relays 1/1 2CDC C09

4 Ordering details CP-T /5.0 2CDC S0009 Description The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality, the new range perfectly supplements the existing products and extends the range appropriately. The devices can be supplied with a three-phase voltage as well as with two-phase mains. Here, ABB offers power supply units with V DC and V DC outputs with 5 A, 10 A, A and A and efficiency of up to 92 %. As in the case of all products, they are designed for an ambient temperature of up to 70 C. All products can be supplied within an AC supply voltage range between to 575 V AC and a DC supply voltage range between to V DC. Ordering details Input voltage range Rated output voltage / current Type Order code Price 1 pce Weight (1 pce) kg (lb) -575 V AC / - V DC V DC / 5 A CP-T /5.0 1SVR2705R V AC / - V DC V DC / 10 A CP-T /10.0 1SVR27055R V AC / - V DC V DC / A CP-T /.0 1SVR27056R (1.77) 1.05 (2.1) 1.75 (.6) 2CDC S V AC / - V DC V DC / A CP-T /.0 1SVR27057R V AC / - V DC V DC / 5 A CP-E /5.0 1SVR2705R00. (7.05) 1.05 (2.1) CP-T /10.0, CP-T / V AC / - V DC V DC / 10 A CP-E /10.0 1SVR27055R V AC / - V DC V DC / A CP-E /.0 1SVR27056R (.6). (7.50) 2CDC S0009 CP-T /.0, CP-T /10.0 2CDC Catalog Electronic Products and Relays 1/1 ABB /

5 Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 CP-T /.0 Input circuit L1, L2, L Rated input voltage U in x V AC Input voltage range -575 V AC - V DC Frequency range AC 7-6 Hz Typical input current 0.6 A 0.65 A 1.1 A 1.72 A Typical power consumption 15 W 270 W 5 W 105 W Inrush current limiting 10 A A 0 A Power failure buffering time min. ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T.15 A / 500 V AC T 5 A / 500 V AC Recommended backup fuse pole miniature circuit breaker ABB Type S Power factor correction (PFC) Yes, passive Discharge current towards PE <.5 ma input / output < 0.25 ma Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit L+, L+, L-, L- Rated output voltage V DC Tolerance of the output voltage % Adjustment range of the output voltage V DC Rated output power 1 W 0 W W 960 W Rated output current I r Ta 60 C 5 A 10 A A A Derating of the output current 60 C < Ta 70 C 2.5 %/ C.5 %/ C Signalling contact 1-1 solid state (max. 60 V DC, 0. A) for output voltage OK Threshold V Insulation voltage 500 V DC Mininum fuse rating to achieve short-circuit protection 1-1 M 60 V DC, m 0. A fast-acting Maximum deviation with load change statical ±1 % ±1 % (single mode) - ± 5 % (parallel mode) change of output voltage ± 0.5 % within the input voltage range Control time at nominal load < 2 ms Starting time after applying at I r max. 1 s the supply voltage with 500 µf max. 1.5 s Rise time at nominal load max. 150 ms with 500 µf max. 500 ms Fall time max. 150 ms Residual ripple and switching peaks BW = MHz 100 mv 0 mv Parallel connection not supported configurable, to increase power, up to 2 devices, min. 0.1 I r - max 0.9 I r ) Series connection not supported yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 5 V Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output combined U/I characteristic curve and hiccup mode continuous short-circuit proof current limiting hiccup mode continuous no-load stability U/I- or Hiccupmode adjustable to increase power, up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing hiccup / fold back behavior Short-circuit protection Short-circuit behaviour Overload protection No-load protection Overtemperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 500 µf 7000 µf 7000 µf 7000 µf /5 ABB Catalog Electronic Products and Relays 1/1 2CDC C09

6 Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 CP-T /.0 General data Efficiency typ. 9 % typ. 90 % typ. 92 % Duty time 100% Dimensions (W x H x D) 7. x 1 x 11. mm (2.92 x. x.6 in) 9 x 1 x 11. mm (.5 x. x.6 in) 150 x 1 x 11. mm (5.91 x. x.6 in) 275. x 1 x 11. mm (10.6 x. x.6 in) Weight 0.7 kg (1.72 lb) 1.05 kg (2.0 lb) kg (.65 lb).275 kg (7.2 lb) Material of housing Metal Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.9 in / 0.9 in) Degree of protection housing / terminals IP / IP Protection class I Electrical connection - input circuit / output circuit / signalling circuit Wire size fine-strand with wire end ferrule 0,2- mm² (-11 AWG) fine-strand without wire end ferrule 0,2-6 mm² (-10 AWG) rigid 0,2-6 mm² (-10 AWG) Stripping length mm (0.1 in) Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1. Nm (15.6 lb.in) Environmental data Ambient temperature range operation C C C rated load C C C storage - +5 C Damp heat (cyclic) (IEC/EN ) 95 % without condensation Vibration (sinusoidal) (IEC/EN ) 2 g, Hz, 2G, each along X, Y, Z axes 60 min / cycle Shock (half-sine) (IEC/EN ) 15 g, 11 ms, axes, 6 faces, times for each face Isolation data Rated insulation voltage U i input circuit / output circuit kv AC input / PE 1.5 kv AC output / PE 0.5 kv AC; 0.71 kv DC signalling output / PE 0.5 kv DC Pollution degree 2 Standards Product standard EN 61- Low Voltage Directive 06/95/EC EMC directive 0/10/EC RoHS directive 02/95/EC Electrical safety EN , UL , UL 50, EN , EN ; EN 60-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity to IEC/EN electrostatic discharge IEC/EN Level (air discharge 15 kv / contact discharge kv) radiated, radio-frequency, electromagnetic field IEC/EN Level (10 V/m) electrical fast transient/burst IEC/EN Level ( kv / 2.5 khz) Level ( kv / 5 khz) surge IEC/EN L-L Level (2 kv) / L-PE Level ( kv) conducted disturbances, induced by radio-frequency fields IEC/EN Level (10 V) power frequency magnetic fields IEC/EN Level (0 A/m) voltage dips, short interruptions and voltage variations IEC/EN dips: >95 % 0.5 ms / >0 % 0.5 ms, interruptions: >95 % 250 ms Interference emission IEC/EN high-frequency radiated IEC/CISPR 22, EN Class B high-frequency conducted IEC/CISPR 22, EN Class B limits for harmonic current emissions IEC/EN Class A Approvals and marks on page /. 2CDC Catalog Electronic Products and Relays 1/1 ABB /6

7 Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 Input circuit L1, L2, L Rated input voltage U in x V AC Input voltage ranget -575 V AC - V DC Frequency range AC 7-6 Hz Typical input current 0.65 A 1.1 A 1.72 A Typical power consumption 26 W 55 W 1050 W Inrush current limiting A 0 A Power failure buffering time min. ms min. 15 ms Internal input fuse per phase 2 A / 600 V AC T.15 A / 500 V AC T 5 A / 500 V AC Power factor correction (PFC) yes, passive Discharge current towards PE <.5 ma input / output < 0.25 ma Indication of operational states Output voltage OUTPUT OK: green LED output voltage OK OUTPUT LOW: red LED output voltage too low Output circuit L+, L+, L-, L- Rated output voltage V DC Tolerance of the output voltage % Adjustment range of the output voltage 7-56 V DC Rated output power 0 W W 960 W Rated output current I r T a 60 C 5 A 10 A A Derating of the output current 60 C < T a 70 C 2.5 %/ C.5 %/ C Maximum deviation with load change statical ±1 % (single mode) ± 5 % (parallel mode) change of output voltage within the ±0.5 % input voltage range Control time at rated load < 2 ms Starting time after applying the supply voltage at Ir max. 1 s with 7000 µf max. 1.5 s Rise time at rated load max. 150 ms with 7000 µf max. 500 ms Fall time max. 150 ms Residual ripple and switching peaks BW = MHz 100 mv 0 mv Parallel connection configurable, to increase power, up to 2 devices, min. 0.1 I r - max 0.9 I r ) to increase power, up to 2 devices, min. 0.1 I r - max. 0.9 I r use active current balancing Series connection yes, to increase voltage, max. 2 devices Resistance to reverse feed approx. 5 V approx. 6 V approx. 6 V Output circuit - No-load, overload and short-circuit behaviour Characteristic curve of output combined U/I and hiccup mode U/I or hiccup mode, configurable Short-circuit protection continuous short-circuit proof Short-circuit behaviour current limiting Overload protection hiccup mode No-load protection continuous no-load stability Over temperature protection yes, automatic recovery after temperature went down Starting of capacitive loads 7000 µf hiccup mode / fold back behavior /7 ABB Catalog Electronic Products and Relays 1/1 2CDC C09

8 Technical data Data at T a = 25 C, U in = x 0 V AC and rated values, unless otherwise indicated Type CP-T /5.0 CP-T /10.0 CP-T /.0 General data Efficiency typ. 91 % typ. 9 % Duty time 100% Dimensions (W x H x D) 9 x 1 x 11. mm (.5 x. x.6 in) 150 x 1 x 11. mm (5.91 x. x.6 in) 275. x 1 x 11. mm (10.6 x. x.6 in) Weight 1.05 kg (2.0 lb) kg (.65 lb).275 kg (7.22 lb) Material of housing Metal Mounting DIN rail (IEC EN 60715), snap-on mounting without any tool Mounting position horizontal Minimum distance to other units horizontal / vertical 25 mm / 25 mm (0.9 in / 0.9 in) Degree of protection housing / terminals IP / IP Protection class I Electrical connection - input circuit / output circuit Wire size fine-strand with wire end ferrule 0.2- mm² (-11 AWG) 0.2- mm² (-11 AWG) / mm² (- AWG) fine-strand without wire end ferrule mm² (-10 AWG) rigid Stripping length mm (0.1 in) Tightening torque input / output 1 Nm (9 lb.in) / 0.6 Nm (5.5 lb.in) 1 Nm (9 lb.in) / 1. Nm (15.6 lb.in) Environmental data Ambient temperature range operation C C C rated load C C C storage - +5 C - +5 C - +5 C Damp heat (cyclic) (IEC/EN ) 95 % without condensation Vibration (sinusoidal) (IEC/EN ) Hz, 2G, each along X, Y, Z axes 6 min / cycle Shock (half-sine) (IEC/EN ) 15G, 11 ms, axes, 6 Faces, times for each face Isolation data Rated insulation voltage U i input circuit / output circuit kv AC input / PE 1.5 kv AC output / PE 0.5 kv AC; 0.71 kv DC Pollution degree 2 Standards Product standard EN 61- Low Voltage Directive 06/95/EC EMC directive 0/10/EC RoHS directive 02/95/EC Electrical safety EN , UL , UL 50, EN , EN ; EN 60-1 Protective low voltage SELV Electromagnetic compatibility Interference immunity to IEC/EN electrostatic discharge IEC/EN Level (air discharge 15 kv / contact discharge kv) radiated, radio-frequency, electromagnetic field IEC/EN Level (10 V/m) electrical fast transient/burst IEC/EN Level ( kv / 5 khz) surge IEC/EN L-L Level (2 kv) / L-PE Level ( kv) conducted disturbances, induced by radio-frequency fields IEC/EN Level (10 V) power frequency magnetic fields IEC/EN Level (0 A/m) voltage dips, short interruptions and voltage variations IEC/EN dips: >95 % 0.5 ms / >0 % 0.5 ms interruptions: >95 % 250 ms Interference emission IEC/EN high-frequency radiated IEC/CISPR 22, EN Class B high-frequency conducted IEC/CISPR 22, EN Class B limits for harmonic current emissions IEC/EN Class A Approvals and marks on page /. 2CDC Catalog Electronic Products and Relays 1/1 ABB /

9 Technical diagrams, Dimensional drawings Technical diagrams Output curve at T U = 25 C dimensions in mm 2 x 0V x 500V supply 2CDC F0x09 2 x 0V x 500V supply 2CDC F0x09 2 x 0V x 500V supply 2CDC F0x Iout [A] Iout [A] Iout [A] CP-T /5.0 CP-T /10.0 CP-T /.0 U/I curve U out in V 2 x 0V x 500V supply 2CDC F0x09 2 x 0 V supply U/I after 5-10 s overload 2CDC F x 0V x 500V supply 2CDC F0x Iout [A] Iout in A Iout [A] CP-T /.0 CP-T /.0 CP-T / x 0V x 500V supply 2CDC F0x09 56 x 0V x 500V supply 2CDC F0x09 U out in V 56 x 0 V supply U/I after 5-10 s overload 2CDC F Iout [A] Iout [A] Iout in A CP-T /10.0 U/I curve CP-T /10.0 CP-T /.0 Dimensional drawings dimensions in mm CP-T /5.0 2CDC F0009 9, , , 1, 2CDC F , 1, 2CDC F CDC F0009 CP-T /10.0, CP-T /5.0 CP-T /.0, CP-T /10.0 CP-T /.0, CP-T /.0 /9 ABB Catalog Electronic Products and Relays 1/1 2CDC C09

10 Technical diagrams Temperature curve at rated load P out [%] P out [%] CDC F CDC F CP-T /.0, CP-T /.0 T a [ C] CP-T /.0, CP-T /10.0 T a [ C] P out [%] CDC F CP-T /5.0, CP-T /10.0, CP-T /5.0 T a [ C] 2CDC Catalog Electronic Products and Relays 1/1 ABB /

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

CP-E range Benefits and advantages

CP-E range Benefits and advantages Benefits and advantages Characteristics Output voltages 5 V, 12 V, 2 V, 8 V DC Adjustable output voltages Benefits Signalling output/contact Output currents 0.625 A / 0.75 A / 1.25 A / 2.5 A / A / 5 A

More information

Primary switch mode power supplies Product group picture

Primary switch mode power supplies Product group picture Primary switch mode power supplies Product group picture /1 ABB Catalog Electronic Products and Relays 2015 2CDC 110 004 C0210 Primary switch mode power supplies Table of contents Primary switch mode power

More information

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-T 24/40.0 Primary switch mode power supply Data sheet Power supply CP-T 24/40.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/10.0 Primary switch mode power supply

Power supply CP-T 24/10.0 Primary switch mode power supply Data sheet Power supply CP-T 24/10.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 24/20.0 Primary switch mode power supply

Power supply CP-T 24/20.0 Primary switch mode power supply Data sheet Power supply CP-T 24/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-T 48/20.0 Primary switch mode power supply Data sheet Power supply CP-T 48/20.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-T 48/5.0 Primary switch mode power supply

Power supply CP-T 48/5.0 Primary switch mode power supply Data sheet Power supply CP-T 48/5.0 Primary switch mode power supply The CP-T range of three-phase power supply units is the youngest member of ABB s power supply family. In terms of design and functionality,

More information

Power supply CP-E 24/20.0

Power supply CP-E 24/20.0 2CDC 271 027 F0008 a OUTPUT L+, L+, L, L-: terminals output b INPUT L, N, PE: terminals input c 13-14: terminals - signalling contact d OUTPUT OK: green LED output voltage OK e OUTPUT LOW: red LED output

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet 2CDC 271 024 F0008 OUTPUT L+, L+, L-, L-: terminals - output INPUT L, N, PE: terminals - input OUTPUT OK: green LED - output voltage OK OUTPUT LOW: red LED - output voltage too low OUTPUT Adjust: potentiometer

More information

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet 2CDC 271 028 F0008 OUTPUT L+, L+, L-, L-: terminals - output Features Rated output voltage 48 V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output current 5 A Rated

More information

Power supply CP-E 24/0.75

Power supply CP-E 24/0.75 2CDC 271 016 F0t06 a OUTPUT L+, L : terminals output b INPUT L, N, PE: terminals input c LOW: red LED output voltage too low d OK: green LED output voltage OK e OUTPUT Adjust: rotary potentiometer output

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

Power supply CP-E 24/2.5

Power supply CP-E 24/2.5 2CDC 271 015 F0t06 a OUTPUT L+, L : terminals output b DC OK: terminal signalling output c INPUT L, N, PE: terminals input d OUTPUT OK: green LED output voltage OK e OUTPUT Adjust: potentiometer adjustment

More information

Power supply CP-D 12/2.1

Power supply CP-D 12/2.1 2CDC 271 025 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 12 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 2.1 A Rated output power

More information

Power supply CP-D 24/1.3

Power supply CP-D 24/1.3 2CDC 271 027 F0t07 a OUTPUT ++/ : terminals output Features Rated output voltage 24 V DC Output voltage adjustable via front face potentiometer OUTPUT Adjust Rated output current 1.3 A Rated output power

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet CDC 0 F0t07 Features Rated control supply voltage -8 V DC, -0 V AC Single-function timer with star-delta change-over One device includes 7 time ranges (0.0 s - 0 min) n/o contacts LEDs for status indication

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC Data sheet Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC The CM-IVN serves to extend the measuring range of the insulation

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC 2CDC 251 244 F0t05 Characteristics Monitoring of DC and AC currents: RMS measuring principle One device includes 3 measuring ranges Over- or undercurrent monitoring configurable Hysteresis adjustable from

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with true OFF-delay and 10 time ranges. All electronic timers from

More information

Switching power supplies CP range, Linear power supplies CP-L range. Content

Switching power supplies CP range, Linear power supplies CP-L range. Content CP range, Linear power supplies CP-L range Content Switching power supplies, primary switch mode, CP range Benefits and advantages... 136 Approvals... 137 Ordering details... 138 Technical data... 11 Dimensional

More information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 Data sheet Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41 The three-phase monitoring relays CM-PSS.x1 monitor the phase parameters phase sequence, phase failure as well as over- and undervoltage.

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.23 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact Data sheet Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact The CT-MVS.12 is a multifunctional electronic timer from the CT-S range and provides 10 timing functions and 10 time ranges.

More information

QUINT-PS AC/24DC/40

QUINT-PS AC/24DC/40 Power supply unit INTERFACE Data sheet 102315_en_02 1 Description PHOENIX CONTACT 2010-04-23 Features QUINT POWER power supply units for plant and special engineering reliably start heavy loads with high

More information

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact Data sheet Electronic timer CT-YDE Star-delta change-over with c/o (SPDT) contact The CT-YDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic

More information

QUINT-PS/ 3AC/24DC/10

QUINT-PS/ 3AC/24DC/10 Primary-switched power supply with SFB technology, 3 AC, output current 10 A INTERFACE Data sheet 103131_en_01 1 Description PHOENIX CONTACT - 09/2009 Features QUINT POWER power supply units Maximum system

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage as well as phase unbalance

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Contents 9/1 Page Description SN4 switched-mode power supply units 9/2 GW4 power supply units 9/3 GD4 power supply units 9/4 Basic Units, Accessories 9/5 Technical data 9/6 Dimensions 9/12 9/2 Description

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 400VAC Features DIN-Rail Description 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 The three-phase monitoring relay CM-MPS.23 monitors the phase parameters phase sequence, phase failure, over- and undervoltage

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103129_en_01 PHOENIX CONTACT - 05/2008 1 Description QUINT POWER power supply units highest system availability

More information

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC

More information

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PBE Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

QUINT-PS-24DC/24DC/10

QUINT-PS-24DC/24DC/10 QUINT-PS-24/24/10 QUINT - converter, primary switched mode, input: 24 V, output: 24 V /10 A INTERFACE Data Sheet PHOENIX CONTACT - 02/2006 Description The QUINT - converter 24 V/10 A converts the voltage

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks. 2CDC 251 054 F0t08 CM-MPN.52 2CDC 251 055 F0t08 CM-MPN.62 2CDC 251 056 F0t08 CM-MPN.72 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage

More information

MINI-PS AC/2X15DC/1

MINI-PS AC/2X15DC/1 MII-PS-100-240AC/2X15DC/1 Power supply unit ITERFACE Data sheet 100299_en_04 1 Description PHOEIX COTACT - 2010-10-20 Features MII POWER is the extremely slim power supply unit with constructional widths

More information

QUINT-PS/ 1AC/24DC/20

QUINT-PS/ 1AC/24DC/20 Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data sheet 103129_en_04 1 Description PHOENIX CONTACT - 02/2010 Features QUINT POWER power supply units Maximum system

More information

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72 The three-phase monitoring relays CM-MPN.x2 monitor the phase parameters phase sequence, phase failure,

More information

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks. 2CDC 251 052 F0t08 CM-MPS.23 2CDC 251 053 F0t08 CM-MPS.43 - relay status, timing - fault message - fault message Adjustment of the tripping delay t V Adjustment of the threshold value for overvoltage 6

More information

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A

Switched mode power supply for DIN rail mounting type SMP23 DC24V/40A Switched mode power supply for DIN rail mounting type SMP DC4V/40A Description Switched mode power supply (SMP) for rail mounting, three-phase supply voltage, high efficiency, integral input filter and

More information

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC Data sheet Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC The CM-IWN.x serves to monitor insulation resistance in accordance with IEC

More information

Electronic timer CT-MFS.21

Electronic timer CT-MFS.21 2CDC 251 053 F0t07 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c Rotary switch for the preselection of the

More information

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact Data sheet Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact The CT-AHE is an electronic time relay with OFF-delay. t is from the CT-E range. The CT-E range is the economic range of ABB s time

More information

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts The CT-MVS.22 is a multifunctional electronic timer from the CT-S range. It provides 11 timing functions and 10 time ranges.

More information

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 Data sheet Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43 The three-phase monitoring relays CM-MPS.x3 monitor the phase parameters phase sequence, phase failure, over- and

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

DSA150 Series. xxx Series. 150 Watts.   AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125. 15 Watts xxx Series Ultra Slim Design 15% Peak Load for 3 seconds Ambient Operation from -1 C to +7 C High Efficiency Selectable Overload Characteristic Selectable Remote Inhibit or Enable 3 Year Warranty

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

Output Voltage* (nom.)(adjustable)

Output Voltage* (nom.)(adjustable) Industrial Power Supplies TIB Series, 80 480 W Slim profile, reduced module width High Power Factor up to 99% High efficiency up to 94% True back power immunity Low heat dissipation 150% peak current Automatic

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Product group picture Product group picture /7 ABB Catalog Electronic Products and Relays 013/014 CDC 110 004 C009 Table of contents Three-phase monitoring relays Product group picture 7 Table of contents 8 Benefits and advantages,

More information

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact Data sheet Electronic timer CT-AWE mpulse-off with auxiliary voltage, 1 c/o (SPDT) contact The CT-AWE is an electronic time relay with mpulse-off function. t is from the CT-E range. The CT-E range is the

More information

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Table of contents Table of contents Three-phase monitoring relays Three-phase monitoring relays 78 Benefits and advantages, Applications 79 Operating controls 80 Selection table - Singlefunctional 81 Ordering details -

More information

Three-phase monitoring relays Product group picture

Three-phase monitoring relays Product group picture Product group picture /7 ABB Catalog Electronic Products and Relays 015 CDC 110 004 C010 Table of contents Three-phase monitoring relays Benefits and advantages, Applications /9 Operating controls /30

More information

Three-phase monitoring relay

Three-phase monitoring relay 1SR 430 824 F9300 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description

UNO-PS/1AC/24DC/150W. Primary-switched power supply unit. Data sheet. 1 Description Primary-switched power supply unit Data sheet 106261_en_02 PHOEIX COTACT 2015-05-13 1 Description The power supply makes a worldwide impression thanks to maximum energy efficiency. ow idling losses (o

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter

Features. LED Driver RACT Watt. TRIAC Dimmable. Single Output RACT12- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

Signal converters Index

Signal converters Index Index Power supplies - Signal and data converters General information...1 Analog signal converters....3.26 Features and benefits...3 Application, approvals and marks...4 Overview...5 -.6 Ordering details...7

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information