C-Series. Circuit Breaker.

Size: px
Start display at page:

Download "C-Series. Circuit Breaker."

Transcription

1 -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in - poles, amps, UL Recognized up to 0VA or 0VD, UL Listed up to 0VA or VD, with choice of time delays, terminal options, actuator styles and colors. Product Highlights: The UL -Series employs a unique arc chute design which allows for higher interrupting capacities of up to 0,000 amps. New thermoset glass filled polter half shell construction provides for increased mechanical and electrical strength. The wiping contacts, mechanical linkage with two step actuation, clean contacts providing high, positive contact pressure and longer contact life Available with American Standard or Metric Threaded Stud terminals, or Saddle lamp screw terminals. Optional mid-trip handle style actuator allows visual indication of electrical overload with or without alarm feature Available with new solid color rocker actuators and unique two-color Visi-rocker actuators, which can be specified to indicate either the ON or TRIPPED/OFF mode Exclusive Rockerguard and Push-To-Reset bezel help prevent inadvertent actuation HANDLE ATUATOR PARALLEL POLE ATUATOR Agency ertifications: UL Recognized UL Standard 0 UL Standard 0 UL Standard 00 UL Listed UL Standard UL Standard A SA Accepted SA ertified TUV ertified VDE ertified * For full Agency ertifications, please see pg. METAL TOGGLE ATUATOR

2 -Series General Specifications Electrical Tables Table A: Lists UL Recognized & SA Accepted configurations and performance capabilities as a omponent Supplementary Protector T, OLO, U Agency ode L 0- T, OLO, U Agency ode L Parallel Pole Notes for Table A: Requires branch circuit backup with a UL LISTED Type K or RK fuse rated A minimum and more than times full load amps t to exceed A for 0 Amp or less rating and t to exceed for through 00 Amp rating *Manufacturer reserves the right to change product specification without prior tice.

3 -Series General Specifications Electrical Tables Table B: Lists UL Recognized and SA Accepted configurations and performance capabilities as a Manual Motor ontroller. RELAY Notes for Table B: UL recognized and SA Accepted at 0V refers to & pole versions used in a Ø, wye connected circuit or -pole version connected with poles breaking. Ø and backed up with series fusing as stated above in te. * Series, Shunt and Relay Trip - Voltage oil onstruction t current coils Table : Lists UL Recognized, SA Accepted, VDE and TUV ertified configurations and performance capabilities as a omponent Supplementary Protector. Notes for Table : General Purpose ratings for UL/SA only. Requires branch circuit backup with a UL LISTED Type K or RK fuse rated A minimum and more than times full load amps t to exceed A for 0 Amp or less rating and t to exceed for through 00 Amp rating.

4 -Series General Specifications Electrical Tables Table D: Lists UL Listed (), SA ertified (. No..-M) configuration and performance capabilities as a Molded ase ircuit Breaker. IRUIT ONFIGURATION MAX. RATING 0 SERIES TABLE D : UL LISTED BRANH IRUIT BREAKERS VOLTAGE FREQUENY D PHASE --- URRENT RATING FULL LOAD AMPS INTERRUPTING APAITY (AMPS) ONSTRUTION NOTES WITHOUT BAKUP FUSE 0,000 Limited to Poles Max from - 00 Amps. 0,000 Limited to Poles Max from - 00 Amps. D ,000 - Poles / 0 D ,000 or Poles ( Poles Required for 0 Volts) ,000 - Poles SERIES 0 0 / 0-0,000 - Poles 0.0-0,000 or Poles. Pole of a Pole Unit is Neutral 0 / 0 0 / or Poles. Pole of a Pole Unit is Neutral 0 0 / ,000 Pole 0 0 / ,000 Pole 0 / ,000 Pole DUAL OIL 0 0 / , Notes from Table D: Special catalog number required. onsult factory. Table E: Lists UL Recognized, SA Accepted configurations and performance capabilities as Protectors, Supplementary for Marine Electrical and Fuel Systems (Guide PEQZ, File E). Ignition Protected per UL 00. UL lassified Small raft Electrical Devices, Marine in accordance with ISO (Guide UZMK, File MQ) as Marine Supplementary Protectors. Table F: Lists UL Listed configurations and performance capabilities as ircuit Breakers for use in ommunications Equipment (Guide DITT, File E), under ULA.

5 -Series General Specifications Electrical Maximum Voltage urrent Rating Standard Voltage oils Auxiliary Switch Rating Insulation Resistance Dielectric Strength Resistance, Impedance O H M S AMPERE RATING Pulse Tolerance urves Multiple of Rated urrent x x 000 I r 00 0 RESISTANE, IMPEDANE VALUES from Line to Load Terminals (Values Based on Series Trip ircuit Breaker) 0 Hz / ycle Inrush Pulse Tolerance.. Time Delay urves, & (0 Amps Max.) Time Delay urves, (00 Amps Max.) (0 Amps Max.). t A, 0 WYE/ VA, 0/0 Hz (see Table A.) UL: A,0 VA. (Table D), 0/0 Hz, VD, UL 0, 0 VD, VA Standard current coils: 0.00, 0.0, 0.00, 0.0,.00,.0,.00,.0, 0.0,.0,.0, 0.0,.0, 0.0, 0.0, 0.0, 0.0, 0.0, 0.0 and 00 amps. Other ratings available, see Ordering Scheme. D - V, V; A - 0V; other ratings available, see Ordering Scheme. SPDT; 0. amps-0va, D Aux. Switch.0A, VD. 0.A, 0VD,/ HP, VA,VDE & TUV.0 VA. Minimum of 00 Megohms at 00 VD. UL, SA: 0 V 0/0 Hz for one minute between all electrically isolated terminals. -Series ircuit Breakers comply with the mm spacing and 0V 0/0 Hz dielectric requirements from hazardous voltage to operator accessible surfaces, between adjacent poles and from main circuits to auxiliary circuits per Publications EN 00 and VDE 00. Values from Line to Load Terminal based on Series Trip ircuit Breaker. Multiple of Rated urrent URRENT (AMPS) x 0x I r.0 0 Hz / ycle Inrush Pulse Tolerance 0.0 Time Delay urves, & (0 Amps Max.) TOLERANE (%) % % % Time Delay urves, (00 Amps Max.) (0 Amps Max.) 0.0 Time in Milliseconds t Mechanical Endurance Trip Free Trip Indication Physical Number of Poles Internal ircuit onfiguration Weight Standard olors Environmental 0,000 ON-OFF per minute; with rated current & voltage All -Series circuit breakers will trip on overload, even when actuator is forcibly held in the ON position. The operating actuator moves positively to the OFF position when an overload causes the breaker to trip. With mid-trip, handle moves to the mid position on electrical trip of the circuit breaker. With mid trip handle with alarm switch, handle moves to the mid position and the alarm switch actuates when the circuit breaker is electrically tripped. - poles 0A; - - 0A; - poles -00A. UL Handle: pole 00A, pole 0A; Rocker: pole 00A. Series (with or without auxiliary switch, mid trip & mid trip with alarm switch) Shunt & Relay with current or voltage trip coils, Dual oil, Switch Only (with or without aux. switch). UL: Series (with or without auxiliary switch, mid-trip & mid-trip with alarm switch). Approx. grams/pole (. oz). Housing: Designed and tested in accordance with requirements of specification MIL-PRF- & MIL-STD-0 as follows: Shock Withstands 00 Gs, ms sawtooth while carrying rated current per Method, Test ondition I. Instantaneous and ultrashort curves 0% of rated current. Vibration Withstands 0.00 excursion from 0- Hz & 0 Gs -00 rated current per Method 0, Test ond. A. Instantaneous & ultrashort curves 0% of rated current. Moisture Resistance Method 0D, i.e., ten -hour + to +, 0-% RH. Salt Spray Method 0, ondition A (0-% % Nal Solution, hrs). Method 0D, ondition A (five Thermal Shock - to + to + to + ). Operating Temperature -0 to +

6 -Series - Agency ertifications Agency ertifications: UL Recognized UL Standard 0 omponent Recognition Program as Protectors, Supplementary (Guide N/QVNU, File E) UL Standard 0 Motor ontrollers, Manual (Guide N/NLRV, File E) UL Standard 00 UL Listed UL Standard Protectors, Supplementary for Marine Electrical & Fuel Systems (Guide PEQZ, File E) Ignition Protection ircuit Breakers, Molded ase, (Guide DIVQ, File E) UL Standard A ommunications Equipment (Guide N/DITT, File E) SA Accepted omponent Supplementary Protector under lass 0, File SA Standard. No. SA ertified ircuit Breaker Model ase (lass 0, File 00), SA Standard. No.. - M TUV ertified EN0, under License No. R00 VDE ertified EN0, VDE 0 under File No. 0

7 -Series Handle UL Recognized Ordering Scheme A B Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting Bezel/Barrier Agency Approval SERIES ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip, one per pole & Alarm Switch POLES One Two IRUIT A Switch Only ( coil) B Series Trip (current) Series Trip (voltage) D Shunt Trip (current) Shunt Trip (voltage) E AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) Three Four F G H, K, Five Six Relay Trip (current) Relay Trip (voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal URRENT RATING (AMPERES) ODE AMPERES VOLTAGE OIL (NORMINAL RATED VOLTAGE) ODE RATING A0 D A D A D A D A D A D A D J0 A J A J A J A J A J A K0 0A L0 0A 0 FREQUENY & DELAY 0 D 0/0Hz, Switch Only 0 D Instantaneous D Ultra Short D Short D Medium D Long 0 0/0Hz Instantaneous 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium 0/0Hz Long 0 D 0/0Hz Instantaneous D 0/0Hz Ultra Short D 0/0Hz Short D 0/0Hz Medium D 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush ode: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle location as viewed from front of breaker: pole - left pole pole - center pole pole - two handles at center poles pole - three handles at center poles pole - four handles at center poles S: Handle moves to mid-position only upon electrical trip of the breaker. Available with circuit codes B,, D, E, F, G, H and K. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Available with circuit codes B &. Standard multipole units have all poles identical except when specifying auxilary switch and/or mixed poles. pole max w/vde. th pole available as Series Trip w/voltage oil only. Switch Only circuits, rated up to 0 amps and poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.). For.0 to 0 amps, select urrent ode 0. For - 0 amps, select urrent ode 0. For -0 amps, select urrent ode 0. For -00 amps, select urrent ode 0. ircuit odes D,E,F,G,H & K available with Terminal odes,, & only. ircuit odes D, F, H & K available up to 0 amps maximum urrent Rating. onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. ers, one aux. switch is supplied, mounted in the extreme right pole. Voltage coils t rated for continuous duty. Available only with delay codes 0 and 0. Available with ircuit odes B & D only, and up to 0 amps maximum. urrent Ratings 0-0 are available up to four poles maximum. Ratings - 00 are available up to two poles maximum. Terminal ode available to 0 amps maximum. Terminal odes,, and available to 0 amps maximum. Terminal odes, & available to 00 amps maximum. Terminal ode available to amps maximum. Terminal ode A available to 00 amps maximum. Terminal odes,, & are t VDE approved. No marking available. onsult factory. VDE/TUV Approval requires dual (I-O, ON-OFF) or I-O markings on all handles. Single pole only. VDE/TUV: 0 amps max.; UL/SA: 0 amps max.; Available in - poles only and limited to A Delays. General Purpose amps t rated for full load amps or to be used in applications with a motor. TERMINAL 0 Stud 0-, threaded Screw 0- Stud /-0, threaded Stud M x 0., threaded Screw M x 0. ATUATOR OLOR & LEGEND olor I-O ON-OFF A B D Red F G Green H J Blue K L Yellow M N Gray P Q Orange R S (short handle) T U 0 MOUNTING/BARRIERS MOUNTING STYLE A B D E Stud M, threaded, 0.0 Double lick onnect / lip Terminal, / lip Terminal A Plug-In Stud, / lip Terminal Dual BARRIERS VOLTAGE Threaded Insert - x 0. inches - x 0. inches < 00 < 00 - x 0. inches > 00 ISO M x mm < 00 ISO M x mm < 00 ISO M x mm > 00 Front Panel Snap-In,.00 [.mm] wide bezel with Handleguard < 00 Legend olor AGENY APPROVAL UL Recognized, SA Accepted D VDE ertified, UL Recognized, SA Accepted E TUV ertified, UL Recognized, SA Accepted H UL onstruction: VDE ertified, UL Recognized, SA Accepted I UL Rec. STD 0, UL Rec. 00 (ignition protected), SA Accepted L UL onstruction: UL Recognized, SA Accepted R UL onstruction: TUV ertified, UL Recognized, SA Accepted

8 -Series Handle Parallel Pole ULA Listed Ordering Scheme A P 0 D 0 M T Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting Max. App. Rating Agency Approval SERIES ATUATOR A Handle, one per pole S Mid-Trip Handle, one per pole T Mid-Trip, one per pole & Alarm Switch POLES Two Three IRUIT P Series Trip (parallel pole) TERMINAL /-0, threaded M, threaded A Plug-In Stud ATUATOR OLOR Red Green Blue Yellow Gray Orange LEGEND ON-OFF B D G J L N Q S Dual Legend olor AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert - x 0. inches ISO M x mm FREQUENY & DELAY D D Ultra Short D D Short D D D Medium D Long MAXIMUM APPLIATION RATING M 0 D URRENT RATING (AMPERES) ODE AMPERES AGENY APPROVAL T ULA Listed (up to 0 amps) K ULA Listed, VDE ertified (up to 00 amps) ULA Listed, TUV ertified (up to 0 amps) ode: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Terminal ode: & : Supplied with bus bars connecting the Line and Load Terminals. A: Line and Load Terminals must be connected to a copper bus bar having a minimum cross section of 0.0 square inches. Above 00 amps, poles are required.

9 -Series Handle UL Listed Ordering Scheme A B 0 0 K G Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting/ Barriers Max. App. Rating Agency Approval 0 SERIES ATUATOR A Handle, one per pole B Handle, one per multipole unit S Mid-Trip Handle, one per pole T Mid-Trip, one per pole & Alarm Switch POLES One Two Three IRUIT B Series Trip (current) AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY D Ultra Short D Short D Medium D Long 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush ode: A: Handle tie pin spacer(s) and retainers provided assembled with multi-pole units. B: Handle located, as viewed from front of breaker in left pole. pole maximum. S: Handle moves to mid-position only upon electrical trip of the breaker. T: Handle moves to mid-position and alarm switch activates only upon electrical trip of the breaker. Standard multipole units have all poles identical except when specifying auxiliary switch and/or mixed poles. & pole circuit breakers required for 0/0 VA (Maximum application rating code ) applications, have all poles identical except when specifying auxiliary / alarm switch which is rmally supplied in extreme right pole per figure B. Terminal barriers are required on all multipole breakers. Third pole is for 0/0 VA applications requiring neutral disconnect. The rd pole has the same construction as poles &. On multi-pole breakers, one auxiliary. switch is supplied, mounted in the extreme right pole. VDE approval on auxiliary switch codes, & only. Auxiliary / Alarm Switch with Independent ircuit ie: separate from breaker circuit, only available with circuit breakers rated 0 amp maximum at 0 VD, VD, and 0 VA. Auxiliary / Alarm Switch with Dependent ircuit ie: same as circuit breaker, is supplied from factory with common terminal of auxiliary / alarm switch connected to line terminal on 0/0 and 0 VA ratings. ircuit breakers rated 0 VA 0 amp maximum can be supplied with Auxiliary/Alarm switch common terminal connected to breaker line terminal. onsult factory for special catalog number. Available up to 0 amps maximum. urrent ratings - 00 with VDE approvals are available up to two poles maximum. Terminal odes, & are t VDE approved. Terminal ode available to 0 amps maximum. Terminal odes,, & available to 0 amps maximum. Terminal odes, & available to 00 amps maximum. Terminal ode A available to 00 amps maximum. VDE and TUV approvals require Dual (I-O, ON-OFF) markings on all handles. Barriers supplied on multi-pole units only. URRENT RATING (AMPERES) ODE AMPERES TERMINAL Stud 0-, threaded Screw 0- Stud /-0, threaded Stud M x 0., threaded Screw M x 0. ATUATOR OLOR & LEGEND olor ON-OFF Dual B D Red G Green J Blue L Yellow N Gray Q Orange S 0 MOUNTING/BARRIERS MOUNTING STYLE Threaded Insert - x 0. inches ISO M x mm Stud M, threaded / lip Terminal / lip Terminal A 0 Plug-In Stud / lip Terminal BARRIERS MAXIMUM APPLIATION RATING A D B D 0/0 A D 0 A F A K 0 A M 0 D AGENY APPROVAL A without approvals F UL Listed, VDE ertified, SA Accepted G UL Listed, SA Accepted J UL Listed, TUV ertified, SA Accepted Legend olor

10 0 -Series Sealed Toggle UL Recognized Ordering Scheme M B Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal Legend Plate 0 Mounting Bezel/Barrier Agency Approval 0 SERIES ATUATOR M Sealed Toggle, one per pole POLES One Two Three IRUIT A Switch Only ( coil) B Series Trip (current) Series Trip (voltage) D Shunt Trip (current) Shunt Trip (voltage) E AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY 0 D 0/0Hz, Switch Only 0 D Instantaneous D Ultra Short D Short D Medium D Long 0 0/0Hz Instantaneous 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium 0/0Hz Long ode M: Handle location as viewed from front of breaker: pole - right pole pole - center pole Switch Only circuits, rated up to 0 amps and poles, and only available with VDE. For.0 to 0 amps, select urrent ode 0. For - 0 amps, select urrent ode 0. For -0 amps, select urrent ode 0. For -00 amps, select urrent ode 0. ircuit odes D,E,F,G,H & K available with Terminal odes,, & only. onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. Voltage coils t rated for continuous duty. Available only with delay codes 0 and 0. Available with ircuit odes B & D only, and up to 0 amps maximum. onsult factory for current ratings -00, in three pole units, available as special catalog number only. Terminal ode available to 0 amps maximum. Terminal odes,, and available to 0 amps maximum. Terminal odes, & available to 00 amps maximum. Terminal ode available to amps maximum. Terminal ode A available to 00 amps maximum. F G H, K, Relay Trip (current) Relay Trip (voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0 D 0/0Hz Instantaneous D 0/0Hz Ultra Short D 0/0Hz Short D 0/0Hz Medium D 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush URRENT RATING (AMPERES) ODE AMPERES VOLTAGE OIL (NORMINAL RATED VOLTAGE) ODE RATING A0 D A D A D A D A D A D A D J0 A TERMINAL Stud 0-, threaded 0 Screw 0- Stud /-0, threaded 0 Stud M x 0., threaded 0 Screw M x 0. LEGEND PLATE 0 No Legend J A J A J A J A 0 MOUNTING/BARRIERS MOUNTING STYLE Standard Hex Nut A Standard Hex Nut (multi-pole units only) Stud M, threaded 0.0 Double lick onnect / lip Terminal / lip Terminal A Plug-In Stud 0 / lip Terminal BARRIERS AGENY APPROVAL UL Recognized, SA Accepted L UL Recognized, SA Accepted with listed construction I UL Recognized, SA Accepted, UL00 ignition protection J A K0 0A L0 0A

11 -Series Rocker UL Recognized Ordering Scheme B 0 0 D Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting/ Barriers Agency Approval SERIES ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend E Indicate ON, legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend H Indicate OFF, legend Push-To-Reset, Visi-Rocker N Indicate OFF, vertical legend O Indicate OFF, horizontal legend P Indicate OFF, legend Single color J Vertical legend K Horizontal legend L No legend Push-To-Reset, Single color R Vertical legend U Horizontal legend V No legend POLES One Two Three URRENT RATING (AMPERES) ODE AMPERES VOLTAGE OIL (NORMINAL RATED VOLTAGE) ODE RATING A0 D A D A D A D A D A D A D J0 A J A J A J A J A J A K0 0A L0 0A IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) Shunt Trip (Voltage) E F G H, K, Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil TERMINAL 0 Stud 0-, threaded Screw 0- Stud /-0, threaded Stud M x 0., threaded Screw M x 0. Stud M, threaded 0.0 Double Quick onnect / lip Terminal / lip Terminal A Plug-In Stud / lip Terminal 0 AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY 0 D 0/0Hz, Switch Only 0 D Instantaneous D Ultra Short D Short D Medium D Long 0 0/0Hz Instantaneous 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium 0/0Hz Long S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0 D 0/0Hz Instantaneous D 0/0Hz Ultra Short D 0/0Hz Short D 0/0Hz Medium D 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush Push-To-Reset actuators have OFF portion of rocker shrouded. Multi-pole breakers have all poles identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: pole left pole; pole center pole. Switch Only circuits, rated up to 0 amps and poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.), For.0 to 0 amps, select urrent ode 0. For - 0 amps, select urrent ode 0. For -0 amps, select urrent ode 0. For -00 amps, select urrent ode 0. ircuit odes D,E,F,G,H & K available with Terminal odes,, & only. ircuit odes D,F,H & K available up to 0 amps maximum urrent Rating. onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.auxilary switch codes, & are VDE approved. Voltage coils t rated for continuous duty. Available only with delay codes 0 and 0. Available with ircuit odes B & D only, and up to 0 amps maximum. urrent Ratings 0-0 are available up to four poles maximum. Ratings -00 are available up to two poles maximum. Terminal ode available to 0 amps maximum. Terminal odes,, & available to 0 amps maximum. Terminal odes, & available to 00 amps maximum. Terminal ode available to amps maximum. Terminal ode A available to 00 amps maximum. Terminal odes,, & are t VDE approved. olor shown is visi and legend with remainder of rocker black Legend on Push-to-reset bezel/shroud is white when single color rocker is ordered. Dual = ON-OFF/I-O legend with actuator codes - G, and J, K, N, O, R, & U. None = legend with actuator codes H, L, P, V. Rockerguard available with actuator codes - L. Push-to-reset available witha ctuator codes N, O, P, R, U, V. VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. VDE/TUV: 0 amps max.; UL/SA: 0 amps max.; Available in - poles only and limited to A Delays. General Purpose amps t rated for full load amps or to be used in applications with a motor. ATUATOR OLOR & LEGEND,, or Visi-olor Marking: Marking olor: Single olor olor: Red Green Blue Yellow Gray Orange I-O A F H K M P R ON-OFF B D G J L N Q S Dual/None Rocker/Handle Visi-Rocker n/a Red Green Blue Yellow Gray Orange 0 MOUNTING/BARRIERS Standard Rocker Bezel - x 0. inches - x 0. inches - x 0. inches ISO M x mm ISO M x mm ISO M x mm Rockerguard Bezel A - x 0. inches - x 0. inches E - x 0. inches G ISO M x mm J ISO M x mm L ISO M x mm Push-To-Reset Bezel B - x 0. inches D - x 0. inches F - x 0. inches H ISO M x mm J ISO M x mm M ISO M x mm BARRIERS AGENY APPROVAL UL Recognized, SA Accepted D VDE ertified, UL Recognized, SA Accepted E TUV ertified, UL Recognized, SA Accepted H UL onstruction: VDE ertified, UL Recognized, SA Accepted I UL Rec. STD 0, UL Rec. 00 (ignition protected), SA Accepted L UL onstruction: UL Recognized, SA Accepted R UL onstruction: TUV ertified, UL Recognized, SA Accepted

12 -Series Rocker UL Listed Ordering Scheme B 0 0 A K G Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting/ Barriers Max. App. Rating Agency Approval SERIES ATUATOR Two olor Visi-Rocker Indicate ON, vertical legend D Indicate ON, horizontal legend F Indicate OFF, vertical legend G Indicate OFF, horizontal legend VERTIAL STYLE HORIZONTAL STYLE INDIATE OLOR LOATION ROKER STYLE DESRIPTIONS INDIATE "ON" INDIATE "OFF" SINGLE OLOR ODE "" ODE "D" ODE "F" ODE "G" Single color J Vertical legend K Horizontal legend ODE "J" ODE "K" POLES One Two Three IRUIT B Series Trip (current) URRENT RATING (AMPERES) ODE AMPERES TERMINAL Stud 0-, threaded Screw 0- w/saddle & washer clamps Stud /-0, threaded Stud M x 0., threaded Screw M x 0. w/saddle & washer clamps Stud M, threaded / lip Terminal, / lip Terminal A, Plug-In Stud, / lip Terminal AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY D Ultra Short D Short D Medium D Long 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush Multi-pole breakers have all breakers identical except when specifying Aux. switch and/ or mixed poles, and have one rocker per breaker. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. Available up to 0 amps maximum. urrent ratings - 00 with VDE approvals are available up to two poles maximum. Terminal ode available to 0 amps maximum. Terminal odes,, & available to 0 amps maximum. Terminal odes,, & A available to 00 amps maximum. Terminal odes, & are t VDE approved. olor shown is visi and legend with remainder of rocker black Dual = ON-OFF/I-O legend on actuator. VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. Rockerguard available with all actuator codes. Barriers supplied on multi-pole units only. & pole circuit breakers required for 0/0 A rating. ATUATOR OLOR & LEGEND or Visi-olor olor: Red Green Blue Yellow Gray Orange Marking: ON-OFF B D G J L N Q S Dual 0 Marking olor: Single olor Rocker/Handle 0 MOUNTING/BARRIERS Standard Rocker Bezel A B D Threaded Insert, per pole - x 0. inches ISO M x mm Rockerguard Bezel Threaded Insert, per pole - x 0. inches ISO M x mm MAXIMUM APPLIATION RATING A D B D 0/0 A D 0 A F A K 0 A M 0 D BARRIERS Visi-Rocker n/a Red Green Blue Yellow Gray Orange AGENY APPROVAL A without approvals F UL Listed, SA ertified, & VDE ertified G UL Listed & SA ertified J UL Listed, SA ertified & TUV ertified

13 -Series Flat Rocker UL Recognized Ordering Scheme B E Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting/ Barriers Agency Approval 0 0 SERIES ATUATOR Two olor Visi-Rocker Indicate OFF, vertical legend Indicate OFF, horizontal legend Single color Vertical legend Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, vertical legend Indicate OFF, horizontal legend Push-To-Reset, Single color Vertical legend Horizontal legend POLES One Two Three IRUIT A Switch Only (No oil) B Series Trip (urrent) Series Trip (Voltage) D Shunt Trip (urrent) Shunt Trip (Voltage) E AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY 0 D 0/0Hz, Switch Only 0 D Instantaneous D Ultra Short D Short D Medium D Long 0 0/0Hz Instantaneous 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium 0/0Hz Long F G H, K, Relay Trip (urrent) Relay Trip (Voltage) Dual oil with Shunt Trip Voltage oil Dual oil with Relay Trip Voltage oil S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0 D 0/0Hz Instantaneous D 0/0Hz Ultra Short D 0/0Hz Short D 0/0Hz Medium D 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush Push-to-reset actuators have OFF portion of rocker shrouded. Multi-pole breakers have all poles identical except when specifying Aux. switch and/or mixed poles, and have one rocker per breaker. Rocker location as viewed from front panel: pole left pole; pole center pole. Switch Only circuits, rated up to 0 amps and poles, and only available with VDE ertification when tied to a protected pole (ircuit ode B,, D or H.). For.0 to 0 amps, select urrent ode 0. For - 0 amps, select urrent ode 0. For -0 amps, select urrent ode 0. For -00 amps, select urrent ode 0. ircuit odes D,E,F,G,H & K available with Terminal odes,, & only. ircuit odes D,F,H & K available up to 0 amps maximum urrent Rating. onsult factory for available Dual oil options, as special catalog number is required. Dual oil Voltage oils with Shunt Trip onstruction trip instantaneously on line voltage. Dual oil Voltage oils require 0VA minimum power to trip instantaneously and are rated for intermittent duty only. Auxiliary Switch available with Series Trip and Switch Only circuits. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole.auxilary switch codes, & are VDE approved. Voltage coils t rated for continuous duty. Available only with delay codes 0 and 0. Available with ircuit odes B & D only, and up to 0 amps maximum. urrent ratings 0-0 are available up to four poles maximum. urrent ratings - 00 are available up to two poles maximum. Terminal ode available to 0 amps maximum. Terminal odes,, & available to 0 amps maximum. Terminal odes, & available to 00 amps maximum. Terminal ode available to amps maximum. Terminal ode A available to 00 amps maximum. Terminal odes,, & are t VDE approved. olor shown is visi & legend with remainder of rocker black. Dual = ON-OFF/I-O legend. Legend on Push-to-reset bezel/shroud is white with single color actuator codes &. Legend on Push-to-reset bezel/shroud matches visi-color of rocker with actuator codes &. VDE/TUV approval requires Dual (I-O, ON-OFF) or I-O markings on rocker. VDE/TUV: 0 amps max.; UL/SA: 0 amps max.; Available in & poles only and limited to A Delays. General Purpose amps t rated for full load amps or to be used in applications with a motor. Recessed OFF SIDE available with actuator codes,,&. Legends on rocker are available in ink stamping only. URRENT RATING (AMPERES) ODE AMPERES ODE RATING A0 D A D A D A D A D A D A D J0 A TERMINAL 0 Stud 0-, threaded Screw 0- Stud /-0, threaded Stud M x 0., threaded Screw M x 0. 0 MOUNTING/BARRIERS Standard Rocker Bezel - x 0. inches - x 0. inches - x 0. inches ISO M x mm ISO M x mm ISO M x mm Recessed Off Rocker - x 0. inches - x 0. inches - x 0. inches A ISO M x mm ISO M x mm E ISO M x mm Push-To-Reset Bezel B - x 0. inches D - x 0. inches F - x 0. inches H ISO M x mm J ISO M x mm M ISO M x mm VOLTAGE OIL (NORMINAL RATED VOLTAGE) J A J A J A J A Stud M, threaded 0.0 Double Quick onnect / lip Terminal / lip Terminal A Plug-In Stud / lip Terminal ATUATOR OLOR & LEGEND,, or Visi-olor Marking: Marking olor: Single olor olor: Red Green Blue Yellow Gray Orange I-O A F H K M P R ON-OFF B D G J L N Q S Dual/None Rocker/Handle Visi-Rocker n/a Red Green Blue Yellow Gray Orange BARRIERS J A K0 0A L0 0A VOLTAGE < 00 < 00 > 00 < 00 < 00 > 00 < 00 < 00 > 00 < 00 < 00 > 00 < 00 < 00 > 00 < 00 < 00 > 00 AGENY APPROVAL UL Recognized, SA Accepted E TUV ertified, UL Recognized, SA Accepted I UL Rec. STD 0, UL Rec. 00 (ignition protected), SA Accepted L UL onstruction: UL Recognized, SA Accepted R UL onstruction: TUV ertified, UL Recognized, SA Accepted

14 -Series Flat Rocker UL Listed Ordering Scheme B 0 0 A K G Series Poles ircuit Aux/Alarm Switch Frequency & Delay urrent Rating Terminal olor 0 Mounting/ Barriers Max. App. Rating Agency Approval 0 SERIES ATUATOR Two olor Visi-Rocker Indicate OFF, vertical legend Indicate OFF, horizontal legend Single color Vertical legend Horizontal legend Push-To-Reset, Visi-Rocker Indicate OFF, vertical legend Indicate OFF, horizontal legend Push-To-Reset, Single color Vertical legend Horizontal legend POLES One Two Three IRUIT B Series Trip (current) AUXILIARY/ALARM SWITH 0 without Aux Switch S.P.D.T., 0.0 Q.. Terminal S.P.D.T., 0. Solder Lug S.P.D.T., 0.0 Q.. Terminal (Gold ontacts) FREQUENY & DELAY D Ultra Short D Short D Medium D Long 0/0Hz Ultra Short 0/0Hz Short 0/0Hz Medium S.P.S.T., 0. Solder Lug S.P.S.T., 0. Q.. Terminal S.P.D.T., 0. Q.. Terminal 0/0Hz Long 0/0Hz Short, Hi-Inrush 0/0Hz Medium, Hi-Inrush 0/0Hz Long, Hi-Inrush D Short, Hi-Inrush D Medium, Hi-Inrush D Long, Hi-Inrush Push-to-reset actuators have OFF portion of rocker shrouded. Multi-pole breakers have all breakers identical except when specifying Aux. switch and/ or mixed poles, and have one rocker per breaker. On multi-pole breakers, one aux. switch is supplied, mounted in the extreme right pole. Available up to 0 amps maximum. urrent ratings - 00 with VDE approvals are available up to two poles maximum. Terminal ode available to 0 amps maximum. Terminal odes,, & available to 0 amps maximum. Terminal odes,, & A available to 00 amps maximum. Terminal odes, & are t VDE approved. olor shown is visi and legend with remainder of rocker black Dual = ON-OFF/I-O legend on actuator. VDE and TUV approval requires Dual (I-O, ON-OFF) markings on rocker. Legend on push-to-reset bezel/shroud is white when single color rocker is ordered. Legend on push-to-reset bezel/shroud matches visi-color of rocker with actuator codes &. Recessed OFF-SIDE available with actuator codes,,, &. Legends on rocker are available in ink stamping only. Barriers supplied on multi-pole units only. & pole circuit breakers required for 0/0 A rating. URRENT RATING (AMPERES) ODE AMPERES TERMINAL Stud 0-, threaded. long Screw 0- w/saddle & washer clamps Stud /-0, threaded. long Stud M x 0., threaded. long Screw M x 0. w/saddle & washer clamps 0 MOUNTING/BARRIERS Standard Rocker Bezel A E F B D Threaded Insert, per pole - x 0. inches ISO M x mm Recessed Off Rocker Threaded Insert, per pole - x 0. inches ISO M x mm Push-To-Reset Bezel Threaded Insert, per pole - x 0. inches ISO M x mm MAXIMUM APPLIATION RATING A D B D 0/0 A D 0 A F A K 0 A M 0 D ATUATOR OLOR & LEGEND or Visi-olor olor: Red Green Blue Yellow Gray Orange Marking: ON-OFF B D G J L N Q S Dual Marking olor: Single olor Rocker/Handle Stud M, threaded mm long / lip Terminal, / lip Terminal A, Plug-In Stud, / lip Terminal BARRIERS Visi-Rocker n/a Red Green Blue Yellow Gray Orange AGENY APPROVAL A without approvals G UL Listed & SA ertified J UL Listed, SA ertified & TUV ertified

15 -Series Handle ircuit & Terminal Diagrams.0 [.]. [.]. DIA [Ø.0] All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified. Available on Series Trip and Switch Only ircuits when called for on multi-pole units. Only one aux. switch is rmally supplied, as viewed in mulit-pole identification scheme.

16 -Series Handle ircuit & Terminal Diagrams LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified. Schematic shown represents current trip circuits. Available only as special catalog number.

17 -Series Handle Form & Fit Drawings LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

18 -Series Handleguard Form & Fit Drawings LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

19 -Series Parellel Pole Form & Fit Drawings LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

20 0 -Series Sealed Toggle Form & Fit Drawings LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

21 -Series Rocker ircuit & Terminal Diagrams LOAD All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified. Schematic shown represents current trip circuit.

22 -Series Rocker Form & Fit Drawings LOAD Dimensions apply to all variations shown. Notice that circuit breaker line and load terminal orientation on indicate OFF is opposite of indicate ON. For pole orientation with horizontal legend, rotate front view clockwise 0. All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

23 -Series Flat Rocker Form & Fit Drawings LOAD For pole orientation with horizontal legend, rotate front view clockwise 0. All dimensions are in inches [millimeters]. Tolerance ±.00 [.] unless otherwise specified.

C-Series. Circuit Breaker

C-Series. Circuit Breaker -Series ircuit Breaker The -Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available in

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker Carling Technologies is proud to introduce the CX-Series circuit breaker, which features a unique and innovative patent pending arc quenching configuration that allows the breaker

More information

CX-Series. Circuit Breaker

CX-Series. Circuit Breaker CX-Series Circuit Breaker The CX-Series circuit breaker features a unique and innovative arc-quenching configuration that allows the breaker to safely handle high amperage and high DC voltage applications

More information

SEALED, ILLUMINATED ROCKER SWITCHES

SEALED, ILLUMINATED ROCKER SWITCHES K/K LOW OST, ROKER FOR WET & DUSTY ENVIRONMENTS The K series rockers are rugged, high performance sealed switches designed for use under severe conditions found in marine, appliance, heavy equipment and

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive haracteristics Extremely low profile of. (.mm) from P to top of switch. Red, green, or yellow LED with spot or full face illumination. Rubber seal construction prevents contact contamination

More information

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features Hexa Multi Module Introduction The E-Plex 366HMM is a six channel DC power distribution module capable of handling loads of up to 15A per channel or 50A total. The six channels can be utilized as either

More information

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts

Introducing. CII FCA-150 Series Relay 50 Amps, 1PST/NO (DM) CII FCAC-150 Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts Introducing CII Series Relay 50 Amps, 1PST/NO (DM) CII Series Relay 50 Amps, 1PST/NO (DM) with 1PDT Auxiliary Contacts Key Features Non-latching relay Balanced force design Corrosion protected metal enclosure

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode power supply. DC 4 V power supplies,

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents

Precision and High Reliability Thermostats Issue 3. Datasheet. Table of Contents Precision and High Reliability Thermostats DESCRIPTION Thermostats can provide either temperature control or overtemperature protection by breaking electrical contact when a specified temperature is reached.

More information

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED POWR RLYS INUOUS DUTY, TYP II, UNSLD INTRMITTNT DUTY, TYP III, UNSLD General Specifications Designed to MIL-R- - Type II Unsealed ontinuous Duty - Type III Unsealed Intermittent Duty - overed/gasketed

More information

Powerpole Connectors - PP75: up to 120 Amps

Powerpole Connectors - PP75: up to 120 Amps Powerpole Connectors - PP75: up to 120 Amps PP75 with Mounting Wings PP75 series Powerpole housings can be used for wire-to-wire, wire-to-board, and wire-to-busbar applications. Wire sizes from #16 AWG

More information

Dual Reversing Module

Dual Reversing Module Dual Reversing Module Introduction The E-Plex 425DRM has been designed to simplify wiring in electronic systems by providing the reversing function local to the motor devices thus eliminating long cable

More information

General Specifications

General Specifications Series M Miniature Rockers Touch Tilt Rockers Toggles Slides Rotaries Programmable Illuminated P Pushbuttons Supplement Accessories Indicators Tactiles Keylocks General Specifications Electrical Capacity

More information

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED INCH-POUND MIL-PRF-6106/19G 18 November 2011 SUPERSEDING MIL-PRF-6106/19F 10 November 2000 PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

Distributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. FEATURES AND SPEIFIATIONS Features and Benefits Board-mounting pegs provide

More information

General Specifications

General Specifications Series F General Specifications Electrical apacity (Resistive Load) Low/Logic Level: m @ V D Other Ratings ontact Resistance: Insulation Resistance: Dielectric Strength: Mechanical Life: Electrical Life:

More information

POST REFLOW HEIGHT DIMENSIONS

POST REFLOW HEIGHT DIMENSIONS MEDER electronic RM Series 4 input / 2 output DESRIPTION The RM05-4A-S-4/2 and RM05-2A2B-S-4/2 are low-profile 4 input / 2 output Relay Modules with an FR-4 substrate and rugged thermoset epoxy overmold.

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES

SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES Your Contact for Industrial Relays SECTION 1 SOCKET COMPATIBLE AND FLANGE MOUNTED RELAYS 1 TO 30 AMPERES SOCKET COMPATIBLE & FLANGE MOUNT RELAYS RELAY SERIES CERTIFIED CLASS 1 DIVISION 2 FOR HAZARDOUS

More information

Switches & Pilot Devices

Switches & Pilot Devices ømm - HW Series Key features: ocking lever removable contact blocks Finger-safe IP0 contacts as standard, other terminal styles available Tamperproof construction All E-stops meet EN8 and are compliant

More information

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and

More information

General Specifications

General Specifications eneral Specifications Electrical apacity (Resistive Load) Logic Level: 0.V maximum @ 8V /D maximum (pplicable Range 0.m ~ 0. @ 0mV ~ 8V) Note: See Supplement Index to find explanation of operating range.

More information

DESCRIPTION CHARACTERISTICS FEATURES DIMENSIONS. Molded DIP Reed Relays. Germany # ++49-(0) , USA #

DESCRIPTION CHARACTERISTICS FEATURES DIMENSIONS. Molded DIP Reed Relays.   Germany # ++49-(0) , USA # DESRIPTION The DIP series is a very compact design having a low profile package and a high profile package. This series is compatible with all DIP relays. HARATERISTIS FEATURES High resistance option available

More information

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19 Index PRODUCT DESCRIPTION PAG ES E110 Series 1PDT, 10 AMP RELAY 2-6 E310 Series 3PDT, 10 AMP RELAY 7-12 E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19 E410 / E415 Series 4PDT, 10/15 AMP RELAY 20-24 E610

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc Product Facts Designed to be the smallest, lightest weight, lowest cost sealed contactor in the industry with its current rating (500+A carry, 2000A interrupt at 320VDC) Built-in coil economizer only 1.7W

More information

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 4PDT, LOW LEVEL TO 5 AMPERES, PERMANENT

More information

General Specifications

General Specifications General Specifications Electrical apacity (Resistive Load) Power Level: 6A @ 25V A & 3A @ 250V A or 6A @ 30V Other Ratings ontact Resistance: Insulation Resistance: ielectric Strength: Mechanical Life:

More information

DPC F - P3-24. Part Number Scheme. Dimensions

DPC F - P3-24. Part Number Scheme. Dimensions Description Definite Purpose Contactor Definite Purpose contactors are electrically operated switching devices specifically designed for the heating, ventilation, air conditioning, heat pump and refrigeration

More information

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test

PCB Relay. --- G2R-1-SN --- G2R-2-SN LED indicator with test PCB Relay A Power Relay for a Variety of Purposes with Various Models Conforms to VDE0 (VDE approval: C0 insulation grade), UL08, CSA., SEV, SEMKO. Meets VDE0700 requirements for household products according

More information

General Specifications

General Specifications eries W lides Rotaries Programmable Illuminated P Pushbuttons upplement Accessories Indicators General pecifications Electrical apacity (Resistive Load) Power Level: 9A @ 125V A or 6A @ 250V A Other Ratings

More information

General Specifications

General Specifications Series M00 Snap-ction Pushbuttons Supplement ccessories Indicators Touch Tilt Tactiles Slides Rotaries Keylocks Programmable Illuminated P Pushbuttons Rockers Toggles eneral Specifications lectrical apacity

More information

150 C 30 F B D 8L 152H C 30 F BD 43 8L

150 C 30 F B D 8L 152H C 30 F BD 43 8L ulletin SM - Smart Motor ontrollers atalog Number Explanation Open and Non-ombination F D L a b c d e f g a ulletin Number Solid-State ontroller b ontroller Type SM- c mpere s N F d Enclosure Type Open

More information

HARTMAN Lightweight High Performance DC Contactors

HARTMAN Lightweight High Performance DC Contactors K Series Connectors Product Facts n Light weight n Small package size n Small footprint n Easy to package in panel assemblies n Buss bar mount or chassis mount n Designed to meet the applicable portions

More information

Table of Contents. Kilovac Time Delay Relays

Table of Contents. Kilovac Time Delay Relays Table of Contents 1600/1700 Series, Delay on Operate, Fixed & Adjustable......................8-2, 8-3 2400 Series, Subminiature, Delay on Operate, Fixed.............................8-4 5600/5700 Series,

More information

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS 20 AMP POWER RELAY RELAYS a 3 1.4 5 a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A V AC resistive and 1.5 kw 3 phase 220 V AC motor loads High contact reliability after long use Usable with direct soldering,

More information

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en

Contactors. Series C137, C163, C164, C165 Single pole contactors for battery voltages Catalogue B60.en Contactors Series C7, C6, C6, C65 Single pole contactors for battery voltages Catalogue B.en Contactors for battery voltages C7, C6, C6, C65 Series With its proven line of C7 through C65 Series contactors

More information

Round Indicator Lights Mounting Hole Page

Round Indicator Lights Mounting Hole Page PRODUCT SERIES Round Indicator Lights Page 8, &. 9. &..7 - NEMA -R.7 8 & 9. 7. 8. 9 7. 8. - NEMA -R.9.9 Indicator Lights.7,.. 7. Rectangular Indicator Lights Panel Cutout. x.. x. 7 & 7. x.8 8. x. 9 & 7.

More information

Smart Power Relay E I...

Smart Power Relay E I... Smart Power Relay E-48-8I... Description The Smart Power Relay E-48-8I.- is a remotely controllable electronic load disconnecting relay with three functions in a single unit: l electronic relay l electronic

More information

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay

Type MCAG 14, 34 T&D. High Stability Circulating Current Relay PROTETION Type MAG, 3 High Stability irculating urrent Relay The MAG relay, used with a stabilising resistor, is designed for applications where sensitive settings with stability on heavy through faults

More information

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT PCB Relay A Power Relay with Various Models High-sensitivity ( mw) and High-capacity ( A) Models available. Low profile:.7 mm max. in height Conforms to VDE (EN0-), UL and CSA.. Meets EN0- requirements

More information

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET INCH-POUND MIL-PRF-83536/32D 03 October 2017 SUPERSEDING MIL-PRF-83536/32C 21 April 2015 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, 3PDT, 25 AMPERES (RESISTIVE),

More information

DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY SEALED

DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY SEALED INCH-POUND DETAIL SPECIFICATION SHEET MS25466F 27 November 2003 SUPERSEDING MS25466E 20 Jan 1989 RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms

Utilization category DC-1 DC-3 DC-5 L/R 1 ms L/R 2 ms L/R 7.5 ms controls IEC Technical data D.C. Power circuit switching Utilization category DC- DC- DC- L/R ms L/R ms L/R 7. ms + + + V A 6.0 6.0 6.0 8 V A 6.0 8.0.0 60 V A 6.0.0. V A 7.0. 0. 0 V A 0.8 0. V A 6.0 6.0

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

FIGURE 1. Design, dimensions, and circuit diagram.

FIGURE 1. Design, dimensions, and circuit diagram. INCH-POUND DETAIL SPECIFICATION SHEET MS25463J 27 November 2003 SUPERSEDING MS25463H 7 December 1993 RELAYS, ELECTROMAGNETIC, 6 PDT, 5 AMPERES, TYPE I, MAGNETIC LATCH, SOCKET MOUNTED, HERMETICALLY SEALED

More information

Distribution/Substation Transformer

Distribution/Substation Transformer Distribution/Substation Transformer Type VFI, Vacuum Fault Interrupter Transformer Option Functional Specification Guide Functional specification for 15 kv, 25 kv, or 35 kv vacuum fault interrupter distribution/substation

More information

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A

Ordering Information. PCB Relay G6RL. Model Number Legend: Low-profile power relay with maximum switching of 10 A PCB Relay G6RL Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) IEC 60947-5-1, AC-15, DC13 Clearance and creepage distance: 10

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Electronic Circuit Breaker ESS1 for System SVS1

Electronic Circuit Breaker ESS1 for System SVS1 Electronic Circuit Breaker for System SVS Description The electronic circuit breaker is designed to ensure selective disconnection of individual s in industrial systems which are powered by a DC 24 V switch

More information

Timers RTE. RTE Series Analog Timers

Timers RTE. RTE Series Analog Timers RTE RTE Key features: 20 time ranges and 10 timing functions Time delays up to 600 hours Space-saving package High repeat accuracy of ± 0.2% ON and timing OUT LE indicators Standard 8- or 11-pin and 11-blade

More information

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz). 121 Series Coaxial Snap On & Screw On Types / 50 Ohm & 75 Ohm These 50 and 75 Ohm coaxial connectors are easily inserted into your printed circuit board using an insertion tool. Solder is eliminated and

More information

DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BOX 3990 COLUMBUS, OH

DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BOX 3990 COLUMBUS, OH DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BO 3990 COLUMBUS, OH 4328-3990 MEMORANDUM FOR MILITARY/INDUSTRY DISTRIBUTION 22 August 208 SUBJECT: Initial Drafts of MIL-PRF-880/F, /2L, /28G,

More information

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US

PCB Relay SPST-NO G6CU-1117P-US G6CU-1114P-US G6CU-1117C-US G6CU-1114C-US SPST-NO + SPST- G6CU-2117P-US G6CU-2114P-US G6CU-2117C-US G6CU-2114C-US PCB Relay SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load Compact: 20 15 10 mm (L W H). Low power consumption: 200 mw. Flux protection or fully sealed construction available. Unique

More information

Application Description

Application Description - N Mechanically Held February ontents Description Page Product Description...... - Application Description... - Features................ - Operation.............. - Instructional Leaflets..... - Standards

More information

Classification Enclosure rating Contact form Contact material

Classification Enclosure rating Contact form Contact material PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kv Clearance and creepage distance: 10 mm.

More information

SERIES FEATURE MAX RATING SEAL RATING APPROVALS MOUNTING CIRCUITRY

SERIES FEATURE MAX RATING SEAL RATING APPROVALS MOUNTING CIRCUITRY SWITH SELETION GUIDE Rocker Switches SERIES FEATURE MAX RATING SEAL RATING APPROVALS MOUNTING IRUITRY (Resistive @ 0VA, VD) (Panel Opening) K Sealed, 6A IP6S UL (E605), SA (LR65),.5 x 0.55 SPST, SPDT Illuminated

More information

22 22, 24, , 18, AWG. 50 ohm 50 ohm. 75 ohm 75 ohm. 95 ohm 95 ohm

22 22, 24, , 18, AWG. 50 ohm 50 ohm. 75 ohm 75 ohm. 95 ohm 95 ohm ircular onnectors MR 4 Series onnectors General Information high density (.080 [2.0] contact centers), lightweight, subminiature, cylindrical connector series featuring crimp contacts and fingertip, push-pull,

More information

Thick Film Resistor Networks Single-In-Line, Molded SIP; 01, 03, 05 Schematics 6, 8, 9 or 10 Pin A Profile and 6, 8 or 10 Pin C Profile

Thick Film Resistor Networks Single-In-Line, Molded SIP; 01, 03, 05 Schematics 6, 8, 9 or 10 Pin A Profile and 6, 8 or 10 Pin C Profile Thick Film Resistor Networks Single-In-Line, Molded SIP; 01, 03, 05 Schematics 6, 8, 9 or 10 Pin Profile and 6, 8 or 10 Pin Profile STNDRD ELETRIL SPEIFITIONS GLOBL MODEL/ SHEMTI xxx01 xxx03 PROFILE RESISTOR

More information

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH

HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH HIGH APAITY, LONG LIFE SUBMINIATURE SWITH PS (AVM3 P) SWITHES FEATURES 10.1 Amp. high contact capacity is available Long life H5recise operating (5mm: type) Flux-resistant construction with integrally

More information

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications Latching Relay MMK CSM_MMK_DS_E_1_1 Mechanically Latching Relays Based on the MM Power Relay Low power consumption due to mechanical latch for economic operation. Relays with mixed coil specifications

More information

www. ElectricalPartManuals. com TypeCW Power Relay Descriptive Bulletin Page 1

www. ElectricalPartManuals. com TypeCW Power Relay Descriptive Bulletin Page 1 November, 1 976 Supersedes DB 41-245, dated July, 1971 E, D, C/21 4/DB Westinghouse Eletri Corporation Relay-Instrument Division Newark, N.J. 711 For Exessive or Reverse Power Detetion CW for Single Phase

More information

Electronic circuit breaker ESS30-Sxxx-DC24V

Electronic circuit breaker ESS30-Sxxx-DC24V Electronic circuit breaker ESS30-Sxxx-DC2V Description The electronic circuit protector ESS30-S with physical isolation is the globally unique electronic over protection for DC 2 V applications as a low

More information

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT RELAY TYPE. DPDT relay with internal diode for coil transient suppression ESTABLISHED RELIABILITY SERIES DESIGNATION MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS DPDT 420/422 DPDT basic relay 420D/422D 420DD/422DD RELAY TYPE DPDT relay with internal diode for coil transient

More information

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS

MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS MAGNETIC-LATCHING ESTABLISHED RELIABILITY TO-5 RELAYS SPDT SERIES 421 SERIES DESIGNATION RELAY TYPE 421 SPDT basic relay 421D 421DD SPDT relay with internal diode for coil transient suppression SPDT relay

More information

TECHNICAL PRODUCT DATASHEET

TECHNICAL PRODUCT DATASHEET FORM-ENG-0018 REV A 06-02-03 ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 SUITABLE FOR OEM DISTRIBUTION ONLY TECHNICAL PRODUCT DATASHEET High Density PDM 21 Output / 10

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

both pin and sleeve contacts.

both pin and sleeve contacts. The different modules are inserted into the appropriate retaining frames (which vary according to the different housing sizes). There they snap in easily and safely. A special removal tool ensures quick

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Slim compact safety relay

Slim compact safety relay Slim compact safety relay SF RELAYS Slim type Max..9 Max..9 Max.. Max..99 Max.. Max.. mm inch FEATURES Forcibly guide contact structure (EN Class A TÜV recognized) Slim profile (mm inch) Compact size with

More information

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE

G5LE. Ordering Information. PCB Relay. A Cubic, Single-pole 10-A Power Relay J MODEL NUMBER LEGEND G5LE PCB Relay G5LE PCB Relay GLE A Cubic, Single-pole 0-A Power Relay D Subminiature sugar cube relay. D Contact ratings of 0 A. D Withstands impulses of up to 4,00 V. D Two types of seal available: flux protection and plastic-sealed.

More information

Powerpole Connectors - PP120: up to 240 Amps

Powerpole Connectors - PP120: up to 240 Amps Powerpole Connectors - : up to 240 Amps series Powerpole housings are designed to accommodate up to 1/0 ( mm²) wires and handle high currents up to 240 amps. Reducing bushings allow to accept down to #8

More information

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b

Low profile safety relay with forcibly guided double contacts FEATURES. Relay height, 14.5mm. 4a2b Low profile safety relay with forcibly guided double contacts SFN4D RELAY 3.3 33.0 FEATURES Relay complies with EN 020, Type B. Polarized magnet system with snap action function Tolerance ±0.3 mm Weight

More information

Altech Corporation What is a Safety Relay?

Altech Corporation What is a Safety Relay? Altech orporation Since 1984, Altech orporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING 1.0 General This specification covers the electrical characteristics and general

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Distributed by: www.jameco.com -8-83-22 The content and copyrights of the attached material are the property of its owner. VDE TV-, AMP ( Form A) Power Relay HE RELAYS.299 3.8.9 RoHS Directive compatibility

More information

PHOENIX CONTACT

PHOENIX CONTACT Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24

More information

For more information, please visit or call toll free at

For more information, please visit   or call toll free at GT3 GT3 Key features: 4 selectable operation modes on each model External start, reset, and gate inputs Panel mount or socket mount Large variety of timing functions and output status indicating LEs UL,

More information

Spring Return DuraDrive Proportional Actuator

Spring Return DuraDrive Proportional Actuator MS40-7043, MS4-7073, MS4-753 Spring Return DuraDrive Proportional Actuator For spring return applications that require proportional modulation control of dampers and valves in HVAC systems. Features: Proportional

More information

SLIM COMPACT SAFETY RELAY

SLIM COMPACT SAFETY RELAY SLIM COMPACT SAFETY RELAY SF-RELAYS Slim type Max. 24.945 Max. 24.945 Max. 4.575 Max. 5.969 Max. 3.52 Max. 3.52 mm inch FEATURES Forcibly guide contact structure (EN525 ClassA TÜV recognized) Slim profile

More information

Bridgeport Magnetics Design Guide

Bridgeport Magnetics Design Guide Bridgeport Magnetics Design Guide Our design guide takes you step by step through the process of designing a toroidal transformer. No engineering design charges for all standard designs. State of the art

More information

Solenoid Data Book 1425 Lake Avenue Woodstock, IL Phone: (815) Toll Free: Sales Fax: (815)

Solenoid Data Book 1425 Lake Avenue Woodstock, IL Phone: (815) Toll Free: Sales Fax: (815) Solenoid Data Book publication v 01.03.001 1425 Lake Avenue Woodstock, IL 60098 Phone: (815) 334-3600 Toll Free: 800-762-0369 Sales Fax: (815) 337-1756 www.guardian-electric.com email: infoge@kelcomail.com

More information

Long Life Cermet Potentiometer 2 Million Cycles

Long Life Cermet Potentiometer 2 Million Cycles Long Life Cermet Potentiometer 2 Million Cycles FEATURES 2 million cycles Cermet element 12.5 mm square single turn panel control 4, 6 and 6.35 shaft diameters and 29 terminal styles Multiple assemblies

More information

Thick Film Resistor Networks Military, MIL-PRF Qualified, Type RZ Dual-In-Line Package, 01, 03, 05 Schematics

Thick Film Resistor Networks Military, MIL-PRF Qualified, Type RZ Dual-In-Line Package, 01, 03, 05 Schematics FEATURES MIL-PRF-83401 qualified Epoxy molded construction All device leads are hot-solder dipped Available in tube pack TCR available in "K" (± 100 ppm/ C) or "M" (± 300 ppm/ C) depending on style 100

More information

Redundant Bus Protection Using High-Impedance Differential Relays

Redundant Bus Protection Using High-Impedance Differential Relays Redundant Bus Protection Using High-Impedance Relays Josh LaBlanc, Schweitzer Engineering Laboratories, Inc. (formerly of Minnesota Power) Michael Thompson, Schweitzer Engineering Laboratories, Inc. 2018

More information

SB 50 Connectors - up to 120 amps

SB 50 Connectors - up to 120 amps Connectors - up to 120 amps Based off the design pioneered by Anderson in 1953, APP s two pole SB connectors set the standard for DC power distribution and battery connections. connectors feature a one

More information

Variable Transformers Product Design & Engineering Data

Variable Transformers Product Design & Engineering Data Variable Transformers Product Design & Engineering Data Product Design & Engineering Data Type 1010B Cutaway General Information STACO ENERGY PRODUCTS CO. is a leading manufacturer of variable transformers,

More information

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH 43218-3990 23 August 2018 MEMORANDUM FOR MILITARY/INDUSTRY DISTRIBUTION SUBJECT: Initial Draft of MIL-PRF-39016/54E. Project

More information

6mm Interface Relays RV8 Series

6mm Interface Relays RV8 Series 6mm Interface Relays RV8 Series PRODUCT DESCRIPTION Electromechanical C1D2 (screw terminal) Solid State (spring clamp) IDEC 6mm interface relays provide a compact solution for general purpose relay requirements.

More information

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples. Miniature High Capacity Relays with SPST-NO 0A and SPST-NO + SPST-NC A SPST-NO 0A and SPST-NO + SPST-NC A for power switching and output that satisfy the needs for space-saving. Small High-capacity Relays

More information