1 6) LQVXODWHG+97HVW7UDQVIRUPHU6\VWHPV 7\SH766IRUIDFWRU\WHVWLQJ 7\SH7669IRURQVLWHWHVWLQJ N9$& N9N9$WHVWV\VWHPZLWKFRXSOLQJFDSDFLWRU 6) DLUEXVKLQJ

2 $SSOLFDWLRQ SF 6 insulated test transformers are especially designed for testing metal-clad switchgear (GIS) in the factory and on-site, and for testing on-site substation equipment. The conventional transformers can be flanged directly to the GIS. This makes testing of such GIS installations possible without feeding them through an air-sf 6 bushing. Therefore, the merits of the encapsulation remains effective also during the testing which is of importance for Partial Discharge tests. These systems are particularly suited for on-site tests of GIS after assembly. In the factory, they allow to test sub-assemblies and components directly in the manufacturing line, thus avoiding transportation to a central test facility, and extra handling. 8VHUEHQHILWV Small and compact dimensions resulting in minimum space requirements Light-weight components Rugged construction to withstand transportation stresses Direct flanging to the test object High safety for operating personnel because of encapsulation of all HV carrying parts Large range of application in conjunction with test bushing for testing of open equipment Built-in HV measuring capacitor 4XDOLW\ Haefely quality assurance complies with ISO The electronic measurement and control devices are designed and manufactured in-house. Our many years of experience in dealing with EMC is therefore an important asset. The design of the test system complies with the VDE 0104 standard for optimal protection of the operating personnel. The test system is shut-down in case of over-voltage, over-current and fast voltage transients. Damage at the fault is minimised. 6\VWHPZLWKHQFDSVXODWHGFRXSOLQJ FDSDFLWRUDQGFRQQHFWLRQIODQJH %ORFNGLDJUDPIRUWHVWLQJHQFDSVXODWHGWHVWREMHFWVLQWKHIDFWRU\V\VWHP766! #" $ % SF6 - air bushing Encapsulated components &' ( )*-+ LV Protection unit &' ( )*,+ 3 way-flange &.' ( )*,+ Insulating Regulating Compensating Power line filter transformer Standard capacitor Test object transformer reactor HV test transformer Coupling capacitor Control cables Power connections Measuring cables Tests with bushing Tests with flanged test object kv Control unit Partial discharge detector Capacitance and tan delta bridge &' ( )*-+ &' ( )*,+ 2

3 %ORFNGLDJUDPIRUWHVWLQJWHVWREMHFWVRQVLWHV\VWHP7669 / #687:9 ;#< =JI:/ /KML5?N 683 < =J<F=G6 < 6 SF6 - air bushing Encapsulated components LV Protection unit O P-Q R ST 3 way-flange O P-Q R ST Insulating Regulating transformer transformer Power line filter HV test transformer Coupling capacitor Standard capacitor Test object kv O P-Q R ST Control unit Control cables Power connections Measuring cables Tests with bushing Tests with flanged test object Partial discharge detector O P-Q R ST Capacitance and tan delta bridge O P-Q R ST 6\VWHPFRPSRQHQWV The test system includes following main components: Regulating transformer type STL (only with factory test system TSS) Power line filter type NLFA Compensating reactor type KDL (only with factory test system TSS) Low voltage protection unit (included in systems rated 510 kv or higher) type NSP Test transformer type TES Control system type OT 247 for factory tests (TSS) or Regulating cubicle with control panel, type TKMT, for on-site tests (TSSV) $YDLODEOH2SWLRQV Encapsulated coupling capacitor type KKS SF 6 -air bushing type DFS and various connection or adaptation flanges between test transformer & bushing & coupling capacitor & test object. Specific base frames or containers for on-site testing. Encapsulated standard capacitor type NKS Control system type OT 257 instead of the OT 247 HV and grounding connections if bushing is used. The connection to test object is usually not included. Partial Discharge detectors Capacitance and power loss factor measuring bridges Other devices upon request. 3

4 U U d U U U 6\VWHPFRPSRQHQWVRI766WHVWV\VWHPVIDFWRU\WHVWLQJ VWGX Y Z\[F]8^2[ _#`XF]8^ UU VX Y!WGX W a V#b#Y a cdfe8cdg [F]8^hi#jGk8lGX V a Y!WGX2X-^ _?mgwg[f]8^,zjy?^ a V#b#Y a8n cdfe8cdg [F]8^hi#jGk8lGX V o Y#p8l2q _!X-r m pjx-^ _?mgwg[f]8^,zjy?^ a V#b#Y a8s cdg [F]8^8`G]8mGX-t!k8lGX V u ]:Zvb#Y?mGW#_!X-r m pw^ YG_#`XF]8^ a V#b#Yyxz s cdg [F]8^8`G]8mGX-t!k8lGX V TSS TES STL 25 KDL 180 TSS TES STL 25 KDL 120 TSS TES STL 50 KDL 360 TSS TES STL 150 KDL 900 TSS TES STL 200 KDL \VWHPFRPSRQHQWVRI7669WHVWV\VWHPVRQVLWHWHVWLQJ VWGX Y Z\[F]8^8]8m euu W2r X Y e X Y!WGX-r m p a V#b#Y a cdfe8cdg [F]8^hi#jGk8lGX V a Y!WGX2X-^ _?mgwg[f]8^,zjy?^ a V#b#Y a8n cdfe8cdg [F]8^hi#jGk8lGX V o Y#p8l2q _!X-r m pjx-^ _?mgwg[f]8^,zjy?^ a V#b#Y a x{ a cdg [F]8^hi#jGk8lGX V TSSV TES TKMT 45 TSSV TES TKMT 30 TSSV TES TKMT 90 TSSV TES TKMT 250 )XQFWLRQRIWKHWHVWV\VWHP The encapsulated test transformer TES is a conventional transformer and steps-up the voltage coming from the regulating transformer. The controls act on the regulating transformer to adjust precisely the input voltage of the TES and thus the test voltage. A compensating reactor KDL is connected between the regulating and the test transformers and compensates the capacitive power required for the test object. This way, the STL and power line filter ratings can be kept small. For on-site tests, the controls (relay technique & push buttons) are integrated into the regulating transformer rack. The latter transformer is dimensioned to avoid a separate compensation reactor. This gives a most compact equipment with a minimum number of components to be transported and connected for testing. $PELHQWFRQGLWLRQVIRUDQHQFDSVXODWHG$&WHVWHTXLSPHQW Height above sea level not limited for the HV parts Relative humidity in main hall under non condensing conditions not limited for the HV parts - Temperature averaged over 24 h for H.V. components min. 0 C, max C - Extreme temperatures for H.V. components min. - 5 C, max C - Temperature for electronic controls and measuring (equipment to operate with the specified measuring errors) min C, max C 4

5 U U d Z ƒ RIWKHWHVWV\VWHPFRPSRQHQWV 5HJXODWLQJWUDQVIRUPHUW\SH67/ With this air-insulated column-type regulating transformer, the input voltage of the test transformer can be varied smoothly & continuously. The unit is for indoor operation. The active part is air insulated and built into a cubicle. The primary winding is galvanically separated from the secondary winding. The driving motor allows a slow and a fast regulating speed ( s from % of the voltage). The zero start interlock forces the operator to start always from zero. The primary breaker and secondary contactor are placed in the regulator cabinet. The power line filter can be built-in the regulating transformer cubicle. 5HJXODWLQJWUDQVIRUPHUW\SH67/ 7HFKQLFDOGDWDRIWKH67/UHJXODWLQJWUDQVIRUPHUVHULHVRQO\VRPHUDWLQJVVKRZQ a V#b#Y a8s o _!X Y#kwb ] }Y?^ ~ cdg `G]8mGX-t!k8lGX V Y#`G]8m k?_?^ V ]8q X _#p?y zr ZJY?mGW2r ]8mGW s ƒ 4 Y?r p8 GX m#y!x,!_?b2b2^f] t STL x 0.5 x STL x 0.6 x STL x 1.8 x STL x 2.0 x c p 3RZHUOLQHILOWHUVW\SH1/)$ For the reduction of line carried noise from the mains. The NLFA filters both phase and is connected to ground. Typical insertion loss per phase measured at 50 Ω / 50 Ω, MIL-STD 220 A > 80 db in the following frequency range of 14 khz...10 MHz 5

6 d Z ƒ &RPSHQVDWLQJUHDFWRUW\SH.'/ For the compensation of the reactive power of capacitive test objects. The air-insulated compensating reactor is connected between the regulating transformer and the test transformer. Therefore, the power rating of the regulating transformer and of a possibly preconnected power filter can be kept small. The compensating reactor comprises 3 inductances which can be combined to achieve up to 7 different power combinations. The reconnection is basically done manually. Upon request (option), a remote re-connection with switches, actuated from the controls, can be offered. &RPSHQVDWLQJUHDFWRUW\SH.'/ 7HFKQLFDOGDWDRIWKH.'/FRPSHQVDWLQJUHDFWRUVHULHVRQO\VRPHUDWLQJVVKRZQ a V#b#Yyxz s o _!X Y#kwb ] }Y?^ ~ o _!X Y#kJ ]8q X _#p?y zr ZJY?mGW2r ]8mGW s ƒ 4 Y?r p8 GX m#y!x,!_?b2b2^f] t cdg G`G]8mGX-t!k8lGX V c p KDL x 0.8 x KDL x 1.2 x KDL x 1.2 x KDL x 1.3 x KDL x 1.3 x /RZYROWDJHSURWHFWLRQGHYLFHW\SH163 Is used to prevent inadmissible high recovery over-voltages on the test transformer in case of disruptive discharges on the test object. The low-voltage protection device NSP acts by opening the power supply and by short-circuiting of the test transformer primary winding within a few hundred microseconds. This avoids repetitive flashovers in the GIS. Regulating transformer STL Test transformer TES Opening switch for disconnecting the power supply Closing switch for short-circuiting the primary winding 6

7 U U Ž d 7HVWWUDQVIRUPHUW\SH7(6 The test transformer is the heart of any SF 6 insulated test system. It is housed in a special tank and is terminated on its HV side by a GIS spacer. All LV terminals are brought out insulated and housed in a connection box. The exciter winding is divided into 2 groups to allow better flexibility in function of the test voltage & load and enhances the compensating reactor efficiency. The spacer type (standard ABB) is chosen acc. to the transformer voltage. Special design are available upon request. A high voltage capacitor is incorporated in the TES tank. The capacitor is used as the high voltage arm of a capacitive divider to perform voltage measurements according to IEC HVWWUDQVIRUPHUW\SH7(6 A secondary part for voltage measurement with a Haefely control unit or measuring instrument is fixed on the transformer housing. A platin-foil thermometer is built in the low voltage winding. The temperature is checked and switches the system off should it be over-loaded. 7HFKQLFDOGDWDRIWKH7(6WUDQVIRUPHUVHULHVDW+] a V#b#Y a8n d ]8q X _#p?y ˆ {}_ t ~ ] }Y?^:_!X8iG Š {}_ t#q ]?_#k4`!_?b#_#` r X _?m `!Y ]8^ X8` r ^F` l2r X r Zvb#Y#k?_?m `!Y _!X ~ŒF ~ ^-r ZJ_?^ V ]8q X _#p?y ~ _?^ X-r _?q k8r W ` #_?^Fp?Y q Y! #Y?q_!X ˆ cd. # cdg! š2 œ žgÿœ b2. š2 œ žgÿœ b u TES TES TES TES TES x x x x x Other voltage ratings are possible! Please contact us. The given power rating is valid at the output of the test transformer. If other components like a coupling capacitor, bushing or connecting flange are added, their internal capacitance reduce the available power available for the test object. 7

8 U Z Z ƒ 'LPHQVLRQV ZHLJKWRIWKH7(6WUDQVIRUPHUVHULHV a V#b#Y a8n d ]8q X _#p?y ˆ cd zr _ ZJY!X Y?^ s Y?m p X- Y?r p8 GX m#y!x,!_?b2b2^f] t c p TES TES TES TES TES 'PHDVXUHPHQWV The indicated PD level is inherent to the test system itself, without considering possible external radiated interference or interference from the power supply. The PD level will be checked during the system test in our works. The above specified PD level presumes that the test system will be equipped with adequate filtering (low voltage filter) and earthing (< 2 Ω). The mains must fulfil the following requirements (according to IEC): Disturbances of supply voltage, peaks phase to ground max. 4 V Harmonics of supply: Ratio of peak to RMS value 2 ± 5 % 7\SLFDODFRXVWLFQRLVHOHYHO measured based on IEC < 75 dba The actual noise level on site depends to a large extent on the on-site conditions, such as type of walls and the geometrical configuration. :RUNWHVWV - High voltage withstand test at 1.2 U n - PD measurement - Short circuit impedance measurement - Measurement of the voltage ratio 7UDQVSRUWDWLRQ JDVFRQQHFWLRQ Usually, the test transformers are shipped assembled and are therefore ready for immediate use. For transportation, the SF 6 gas pressure should be reduced to 1.2 bar. The standard filling valve is compatible with DILO treatment equipment. Other valves are available under request. The SF 6 gas treatment equipment is not included in our scope of supply. 8

9 &RQWUROVW\SH27 The Operating Terminal OT 247 provides a safe and easy computer-aided operation of transformer-type AC high voltage test systems. The unit is built into a standard 19" desktop housing. It has a high electromagnetic compatibility and does not need additional screening. Due to the built-in safety interlocks the operator can fully concentrate on the test object. As an option, the more sophisticated OT 257 can be offered. &RQWUROVW\SH27 6RIWZDUH The program allows the following operations: Switching On/Off of the primary circuit breaker Switching On/Off of the contactor (High Voltage On/Off) Manual variation of the output high voltage, two speed levels Automatic zero start-up after switching off the high voltage Automatic setting of the output high voltage to a preset value with a pre-set speed (kv/s) Timer for switching off the high voltage after a preset time At any time and in addition to the output high voltage a selection of four of the following information can be displayed: Status of the protection system Status of the safety circuit and the emergency trip Output voltage and current of the regulating transformer Timer +LJK9ROWDJHPHDVXUHPHQW The measuring signal is derived from the built-in HV divider of the TES transformer. The value of the high voltage is permanently displayed, either as peak value/ 2 or as RMS value. In case of flashover at the test object the control unit automatically stores the last voltage measurement as well as the polarity of the high voltage during the discharge. Measuring error of the electronic ± 0.5 % of the measured value between 10 % and 100 % of the system output voltage Measuring error of the complete measuring ± 1 % of the measured value between 10 % system (divider/coupling quadripole, and 100 % of the output voltage electronic system) at 50/60 Hz. 9

10 U d Z ƒ &RQWUROVIRURQVLWHWHVWVW\SH7.07 RIWKHFRQWUROV7.07 The controls TKMT house the control panel with push buttons, the HV-meter DMI 551 and the regulating transformer. Upon request, the power cables can be fitted with Multicontact plugs. RIWKHFRQWUROVSDUW This push button controls allow the following functions and indications: Emergency stop Primary breaker On - Off Secondary contactor On - Off Horn Setting of voltage variation speed Max. current setting Key-switch Indication of test transformer temperature Indication of Primary current and voltage Indication of test transformer current on HV side. &RQWUROVW\SH7.07 Warning lamps (one green, one red) are mounted on the TKMT cabinet. Plugs are provided for a safety circuit (Interlock). RIWKHUHJXODWLQJWUDQVIRUPHUSDUW With this air insulated regulating transformer the input voltage of the test transformer can be varied smoothly & continuously. The unit is for indoor operation, air-cooled. The primary winding is galvanically separated from the secondary winding. The zero start interlock forces the operator to start always from zero. 7HFKQLFDOGDWDRIWKH7.07FRQWUROVVHULHV a V#b#Y a x{ a cdg o _!X Y#kwb ] }Y?^ ~ [F]8^hi#jGk8lGX V Y#`G]8m k?_?^ V ]8q X _#p?y zr ZJY?mGW2r ]8mGW s ƒ 4 _?b2b2^f] t Y?r p8 GX m#y!x:_?b2b2^f] t c p TKMT x 0.8 x TKMT x 0.8 x TKMT x 0.8 x TKMT x 0.8 x

11 Ä ¾ 'LJLWDOPHDVXULQJLQVWUXPHQWW\SH'0, Used in conjunction with the TKMT controls for on-site tests, the DMI 551 is a multi purpose measuring instrument for all kind of voltages present in high voltage test laboratories. The instrument has a high EMC compatibility and does not need additional screening. It is built into a 19" standard housing, 3 units in height. «± ² ³ µ F ³ µ ² «± ¹ ¹ º»¼»½»¾» Ç È ÉÊËÌ Í ÎÉ:Ï ÐÑ Ò Ñ ÊÓ2Ô Õ ÈÖÖ À ¼ Á Â Å Ã Æ ½ ª 'LJLWDOPHDVXULQJLQVWUXPHQW W\SH'0, The DMI 551 has 3 separate analogue measuring channels and is available in all combinations. E.g. as a pure impulse measuring device up to a multi purpose AC, DC, IMP measuring device. Due to its modular system a later upgrade can be performed easily on-site without sending the device back to the Haefely works. +DUGDQG6RIWZDUH Are based on Haefely in house developments especially adapted to the demanding high voltage test environment. 3 individual measuring channels allow for better performance and higher reliability. Microprocessor control is based on PC 104 industrial standard and built with high quality industrial strength components. The illuminated LCD CFL screen has a size of 120 x 64 mm and offer a resolution of 240 x 128 dots. Software is stored on an EPROM and can be updated if required. 7HFKQLFDOGDWD Technical data are listed for a DMI equipped with only the AC measuring channel. $&9ROWDJH0HDVXULQJ&KDQQHO Measured values Peak / 2 (capacitor), RMS (fast A/D conversion) Display kv, 4 Digits Accuracy ± 0,5 %, ± 3 Counts Input voltage max 150 V RMS Measuring range % Range setting automatic Input impedance 1 MΩ, 60 pf Frequency of the measured voltage Hz, +/- 0.5 % Accuracy 16 2/ Hz, +/- 1 % Accuracy Flash detection polarity and last Peak / 2 11

12 U Z Z ƒ 2SWLRQV (QFDSVXODWHG&RXSOLQJ&DSDFLWRU..6 With an adapted coupling quadripole, the coupling capacitor is used for sensitive partial discharge measurements. Its capacitance is determined depending of the test object capacitance. The pre-tested active part is installed in an insulating tube, which is in turn installed in the coupling capacitor tube. This type of coupling capacitor has a high capacitance value, a good partial discharge behaviour and a high reliability. The capacitor vessel is equipped with a pressure gauge and filling valve. &RXSOLQJFDSDFLWRUN9 7HFKQLFDOGDWDRIWKHFRXSOLQJFDSDFLWRUV..6 a V#b#Yyxx d ]8q X _#p?y ˆ u _?b#_#` r X _?m `!Y zr _ ZJY!X Y?^ s Y?m p X- Y?r p8 GX m#y!x,!_?b2b2^f] t cd m2 c p KKS KKS KKS KKS Other voltage ratings are possible. Please contact us. 12

13 U Z Z ƒ 6) DLUEXVKLQJV')6DQGFRQQHFWLRQIODQJHV The SF 6 -air bushings are SF 6 insulated, for outdoor use in any mounting position, with: Cylindrical FRP - insulator with silicone ribs Metal housing flange with gas fitting, spacer and lifting lugs. An aluminium top electrode is mounted on the top bushing to allow PD free testing. A pressure indicator is available as an option. 7HFKQLFDOGDWDRIWKHEXVKLQJV')6 a V#b#Yyz d ]8q X _#p?y ˆ cd zr _ ZJY!X Y?^ N9WHVWV\VWHPZLWK6)DLUEXVKLQJ s Y?m p X- Y?r p8 GX m#y!x,!_?b2b2^f] t c p DFS DFS DFS DFS &RQQHFWLRQIODQJHV A multitude of connection flanges can be realised to connect: coupling capacitors SF 6 -air bushings test object test transformer These flanges can be equipped with a switch for separating a coupling capacitor from the test transformer for example. This helps to increase the capacitive load range of the test system. Earthing or PD calibration studs can be integrated too. 7\SLFDOZD\FRQQHFWLRQIODQJH Special base frames for the test transformer, coupling capacitor, SF 6 -air bushing can be realised. 13

14 6SHFLDOVROXWLRQV Ä7HVWDFURVVRSHQVZLWFK³DQGWHVWVDW+] 7HVWDFURVVRSHQVZLWFK Some customers require special tests on the breakers or disconnecting switches. This is a test across open switch on the open breaker. Each of its contacts is energised separately. One of the voltage is phase shifted by 180 degrees, which allows to reach test voltage levels higher than the single test transformer nominal rating. The manufacturer thus needs 2 test transformers in his works. 37WHVWVDW+] In order to keep the instruments transformers in the circuit, tests have to be carried-out with a higher frequency, for example 180 Hz. A frequency converter (FU) is required for this test. %ORFNGLDJUDPIRUWHVWÄDFURVVRSHQVZLWFK³ Regulating transformer STL Test transformer 400 kv TES 1 Partial discharge Detector TE 571 Test object at works kv Control unit OT 247 Frequency Converter FU Test transformer 400 kv TES 2 Coupling Capacitor KKS Dielectric & PD tests Tests at 180 Hz Test across open switch" 7HVWÄDFURVVRSHQVZLWFK³ZLWKERWK7(6RXWSXWVSKDVHVKLIWHGE\GHJUHHV Output TES 1 Output TES 2 Effective test voltage across test object is the sum of the outputs of the TES 1 and the TES 2. 14

15 &RQWDLQHUV For storage and transportation of the AC test system test system including the high voltage transformer TES. If possible, the container is subdivided by a partition in a "control room" and a "storage room". If not enough space is available, a separate container serves as control room. The regulating transformer TKMT with controls is installed inside the control room. The feeding voltage is transferred via special cables to the HV transformer. A desk with drawers can also be installed in the control room, which is lighted. Provision for a safety circuit connection is given. The container is usually equipped with a power distribution panel, including protection system and main circuit breaker. An opening is provided for the power and control cables which can be closed with a hinged door. All pieces of equipment are earthed at a central point, accessible from the outside of the container. The test transformer, eventual bushing with HV electrode as well as base frames are arranged inside the storage room / container. These elements are secured by adapted fastenings during transportation. Haefely uses the following standard steel container which are specially customised for the test equipment arrangement. A special double component paint, standard light grey RAL 9002, is used and the centre of gravity is clearly indicated. They can be transported by ship, train and lorry. Dimensions Control room container 10 feet Storage container 20 feet Length x Width x Height 3.0 x 2.5 x 2.6 m 6.1 x 2.5 x 2.6 m IHHWFRQWUROURRPFRQWDLQHUZLWK7.07FRQWUROV 15

16 2VFLOODWLQJ6ZLWFKLQJ,PSXOVH This generator allows to test GIS with oscillating switching impulses (OSI). It is fully independent from the AC components of the whole test system. It generates an OSI impulse of a few kv which is amplified by the test transformer TES itself. The system charges a bank of impulse capacitors which are discharged through the TES windings. The DMI 551 Imp (with options DC and Imp), with a special software displays the charging and the OSI test voltages. The OSI measurement signal is taken from the secondary part on the TES transformer. 400 V,QFOXGHVWKHIROORZLQJPDLQFRPSRQHQWV Impulse capacitors with connection circuit DC Charging and measuring circuits Polarity change circuit Integrated command panel Digital measuring instrument DMI 551 IMP OSI generator Test transformer Test object 7\SLFDORXWSXWYROWDJH 26,UDFN Max. output OSI voltage with test transformer TES 600 kv approx. 900 kv Max. output OSI voltage with test transformer TES 750 kv approx kv The value depends of the test object load. 16

17 7HFKQLFDOVHUYLFHV Haefely Test AG has a dedicated Technical Services dept. with an experienced team of engineers doing the internal tests as well as the commissioning on-site and final testing of the test installations. Our Technical Services dept. does also preventive maintenance, repairs and calibrations if required. This responsive team allows to minimise eventual down-times and assures the shortest possible reaction time should any question arise. The full coverage of the warranty is granted only if Haefely Test AG has carried out the Technical Services. The charges for the delegation of our personnel are based on the terms and conditions of the Swiss Association of Machinery Manufacturers.,QVWDOODWLRQ Big installations require our experienced team of mechanical erectors for supervising the assembly the test systems. 6\VWHPDQG$FFHSWDQFH7HVWVRQ6LWH Once the system is erected, we delegate our engineers for doing the systems tests at the customers. The system test shall proof that the system works according to the specification at customer s site and gives a first training to the operating staff. These tests can also be done with a real test object. 7UDLQLQJRI2SHUDWLQJ3HUVRQQHO The training is carried out by the Haefely senior engineer immediately after the systems tests. Detailed explanations about the use of the system, controls and measuring instruments are given, in addition to the operating manuals. 3UHYHQWLYH0DLQWHQDQFH 6HUYLFHYLVLWV Haefely Test AG can offer a regular service & maintenance visit on-site for checking the system condition & proposing necessary works. This is particularly appreciated for production line equipment. This visit can also be combined with the system re-calibration. 17

18 $FFHVVRULHV 0HDVXULQJRI3DUWLDO'LVFKDUJHV By adding a coupling quadripole (option), the encapsulated coupling capacitor type KKS can be used for measuring partial discharges. Various coupling quadripoles can be used. Digital or analogue PD detectors can then be used depending of the customer s needs. Please consult the Tettex General Catalogue for more information. 'LJLWDOSDUWLDOGLVFKDUJHGHWHFWRUW\SH''; 0HDVXULQJRIFDSDFLWDQFHDQGWDQG The encapsulated standard capacitors type NKS are used in conjunction with C and tan δ bridges for measuring capacitance and tan δ values. Digital or analogue bridges can then be used depending of the customer s needs. For more details, see the Tettex General Catalogue. &DSDFLWDQFHDQGWDQδEULGJHW\SH 18

19 2UGHUWH[W 7\SH766IRU IDFWRU\WHVWLQJ &RGH &RGH 7\SH7669IRU RQVLWHWHVWLQJ - Complete basic system TSS... kv,... kva TSSV... kv,... kva - SF 6 - insulated HV transformer with a built-in HV measuring capacitor TES... kv,... kva TES... kv,... kva - Switching and regulating cubicle STL... kva TKMT... kva - Compensating reactor KDL... kva incl. in TKMT - Control unit with set of control and measuring cables, 20 m OT 247 in desk top housing incl. in TKMT - Voltage measurement incl. in OT 247 DMI 551 incl. in TKMT - Power line filter NLFA as option - Low voltage protection device (only included for systems 510 kv and above) - One set of operating instructions and test reports in English or German) NSP as option 2SWLRQV - Computerised control unit with set of control and measuring cables, 20 m OT 257 with desk and mini-rack - Encapsulated coupling capacitor KKS... kv,... nf KKS... kv,... nf - SF 6 - air bushing DFS... kv DFS... kv - Connection flanges ZF... ZF... - Container for storage, transportation & test room --- CONT AC - OSI generation rack TES OSI... kv TES OSI... kv - Technical services DEL DEL - Partial Discharge detectors & - C & tan δ measuring bridges several models available, please see the Tettex General Catalogue --- several models available, please see the Tettex General Catalogue - Other possibilities please contact us please contact us 19

20 /LVWRIOHDIOHWV Modular AC test systems up to 300 kv, 0.25 A E AC voltage test systems up to 1800 kv, 40 A E Instrumentation for Partial Discharge, C and tan δ, accuracy and resistance Tettex General Catalogue Haefely Test AG offers also a complete range of impulse test systems for both impulse voltage and impulse current applications. 7HVWWUDQVIRUPHUW\SH7(6IODQJHGRQD*,6 Haefely Test AG Lehenmattstrasse 353 CH Basel Switzerland Subject to technical modifications without notice. Tel Fax sales@haefely.com 20

Onsite Mobile AC High Voltage Test System

Onsite Mobile AC High Voltage Test System TSGMF(T) series Onsite Mobile AC High Voltage Test System Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument

More information

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications: SGMF(T) series Onsite Mobile AC High Voltage Test System On-site AC high voltage test systems are used for voltage withstanding test, partial discharge measurement, tan delta measurement on those instrument

More information

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax : NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata - 700 032, Tel : 033 2477 3126; Fax : 033 2477 2403 www.ntplindia.com SPECIFICATION NTPL MAKE MICRO-CONTROLLER BASED AUTOMATIC 50KV/10A AC HIGH VOLTAGE

More information

شركة الوقت للكهرباء والمقاوالت ذ.م.م.

شركة الوقت للكهرباء والمقاوالت ذ.م.م. CONTRACTING COMPANY W.L.L. is a leading corporate in the United Arab Emirates offering quality services in the field of High Voltage Electrical work 400, 132 & 33 kv and Medium Voltage Power Distribution

More information

AC Voltage Test System with Transformer

AC Voltage Test System with Transformer AC Voltage Test System with Transformer Application AC test transformers are especially designed for testing objects of medium capacitance in the factory. These systems are particularly suited for tests

More information

AC Dielectric Test Sets

AC Dielectric Test Sets AC Dielectric Test Sets AC Test Systems Hipotronics standard line of AC Test Systems are designed to perform high voltage AC tests on electrical apparatus in accordance with IEC60, IEEE 4 and IEC 270 and

More information

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S

KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT. reliable. precision. HIGH V O L T A G E T E S T S OLUTION S KIT 4.0 HIGH VOLTAGE CONSTRUCTION KIT reliable. precision. HIGH V O L T A G E T E S T S OLUTION S 2 General Description GENERAL DESCRIPTION APPLICATION The KIT 4.0 is a high voltage system made of easily

More information

700 Series AC Dielectric Test Sets

700 Series AC Dielectric Test Sets 700 Series AC Dielectric Test Sets AC Test Systems HAEFELY HIPOTRONICS standard line of AC Dielectric Test Systems is designed to perform high voltage AC tests on electrical apparatus in accordance with

More information

High Votage Module AC/DC/Impulse Test System

High Votage Module AC/DC/Impulse Test System TSGADI Series High Votage Module AC/DC/Impulse Test System A digital control and measuring system is used to be control the difference output AC/DC/Impulse and related protection device such as over voltage

More information

AC Resonant Test Systems Tank Type Up to 150 kv

AC Resonant Test Systems Tank Type Up to 150 kv R AC Resonant Test Systems Tank Type Up to 150 kv PHENIX TECHNOLOGIES Testing Applications AC Resonant Test Systems are used where the load is largely capacitive with very low real power losses such as

More information

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY 9. INTRODUCTION Control Cabling The protection and control equipment in power plants and substations is influenced by various of environmental conditions. One of the most significant environmental factor

More information

700 Series AC Dielectric Test Sets

700 Series AC Dielectric Test Sets 700 Series AC Dielectric Test Sets AC Test Systems HAEFELY HIPOTRONICS standard line of AC Test Systems is designed to perform high voltage AC tests on electrical apparatus in accordance with IEC60, IEEE

More information

Three-Phase Transformer Test Systems

Three-Phase Transformer Test Systems Three-Phase Transformer Test Systems PHENIX TECHNOLOGIES R Testing Applications Models Available Perform tests on utility distribution and power transformers in accordance with IEC 60076 and ANSI / IEEE

More information

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

Power Frequency Withstand Voltage On-site testing of 400 kv GIS Power Frequency Withstand Voltage On-site testing of 400 kv GIS D. Anaraki Ardakani, A. Omidkhoda, M. Solati High Voltage Engineering Center ACECR Tehran, Iran Da_ardakani@yahoo.com Paper Reference Number:

More information

Mitigating Murphy s Law While Test. Frédéric Dollinger

Mitigating Murphy s Law While Test. Frédéric Dollinger Mitigating Murphy s Law While Test Frédéric Dollinger Curriculum Vitae Frédéric Dollinger HAEFELY HIPOTRONICS factory Basel Switzerland Area Sales & Marketing Manager Dipl. Ing. / M.Sc. Mechatronic Language:

More information

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

GENERATOR TESTING APPLICATION GUIDE.  reliable. precision. GENERATOR TESTING APPLICATION GUIDE www.haefely-hipotronics.com reliable. precision. 2 GENERATOR TESTING CONTENTS Product Line Overview 3 AC Hipot Testing 4 Partial Discharge Measurement 5 DC Hipot Testing

More information

AC Resonant Test Systems Tank Type Up to 500 kv

AC Resonant Test Systems Tank Type Up to 500 kv R AC Resonant Test Systems Tank Type Up to 500 kv PHENIX TECHNOLOGIES Testing Applications High power AC Resonant Test Systems are used where the load is largely capacitive with very low real power losses

More information

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned Part 1 - General Scope and Product Description 1.0 This specification contains the minimum design

More information

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS

TMS 580. Transformer Loss Measuring System FEATURES BENEFITS APPLICATIONS TMS 580 Transformer Loss Measuring System The measurement of the losses in power transformers is an indispensable quality-verification process. Due to the fact that normally the transformer user puts a

More information

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS

PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS PRODUCT PORTFOLIO TEST AND MEASURING SYSTEMS n Quality made in Germany n Standardized and customized solutions n Turn key projects, all from one hand 0.1-1/1 Product Portfolio Test and Measuring Systems

More information

SG A. Impulse Voltage Test System, kv / kj APPLICATION

SG A. Impulse Voltage Test System, kv / kj APPLICATION SG A Impulse Voltage Test System, 200 3 000 kv / 10 300 kj APPLICATION SG A impulse test systems can be used to generate impulse voltages simulating lightning strokes and switching surges. The total charging

More information

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC

Catalogue 1SFC en, Edition 3 November 2003 Supersedes Catalogue 1SFC en, Edition 2 November Arc Guard System TVOC Catalogue 1SFC 266006-en, Edition 3 November 2003 Supersedes Catalogue 1SFC 266006-en, Edition 2 November 2000 Arc Guard System TVOC System units The two units of the are used as below: Approvals 1. with

More information

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS 1.0 SCOPE The following specification describes the features, design, and application of the Series 7200A

More information

HV Module Systems for Testing, Training and Research

HV Module Systems for Testing, Training and Research HV Module Systems for Testing, Training and Research 4.0/3 Application Advantages Principle of HV circuit Smaller high-voltage (HV) test systems are necessary for research, development and quality testing

More information

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) CP RC Resonance circuit for GIS testing A new approach to testing gas-insulated switchgear Testing gas-insulated switchgear

More information

VARIABLE FREQUENCY RESONANT TEST SYSTEM

VARIABLE FREQUENCY RESONANT TEST SYSTEM VARIABLE FREQUENCY RESONANT TEST SYSTEM 400kV,1200kVA Tank Type Reactor for Outdoor Cable Test Field 650kV, 5850kVA, Cylinder Type Reactors for Onsite Testing of GIS and Cable PHENIX Variable Frequency

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: All ENGINEERING COMMISSIONING PROCEDURE ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing of new and

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

Automatic Transformer Winding Analyser

Automatic Transformer Winding Analyser 2293 Automatic Transformer Winding Analyser The 2293 is an automatic winding analyser, optimized for three phase power and distribution transformer measurements. It uniquely combines winding resistance

More information

EI HIGH VOLTAGE INSULATION TESTING POLICY

EI HIGH VOLTAGE INSULATION TESTING POLICY Network(s): Summary: ENGINEERING INSTRUCTION EI 09-0001 HIGH VOLTAGE INSULATION TESTING POLICY EPN, LPN, SPN This engineering instruction details the policy for the on-site insulation testing of new and

More information

Specialists in HV and MV test and diagnostics. Testing in Substations

Specialists in HV and MV test and diagnostics. Testing in Substations Specialists in HV and MV test and diagnostics Testing in Substations Testing in Substations Testing in Substations At 4fores we specialize in the diagnosis and measurement of all types of existing technologies

More information

Impulse Voltage Test System SGVA kv, kj

Impulse Voltage Test System SGVA kv, kj Impulse Voltage Test System SGVA 200-10 000 kv, 10-1 500 kj Impulse test system with 4000 kv impulse generator & divider and 3600 kv multiple chopping gap at Hyundai Heavy Industries, Ulsan, South Korea

More information

ECP HV INSULATION TESTING

ECP HV INSULATION TESTING Document Number: ECP 11-0006 Network(s): Summary: ENGINEERING COMMISSIONING PROCEDURE EPN, LPN, SPN ECP 11-0006 HV INSULATION TESTING This standard details the policy for the on-site insulation testing

More information

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 4.0 Sectionalizer Construction... 4 5.0 Mechanism... 6 6.0 Solid Dielectric

More information

Mobile Power Transformer Test Systm

Mobile Power Transformer Test Systm TMPTTS Series Mobile Power Transformer Test Systm MPTTS Series Mobile Power Transformer Test System is design to test and diagnose in both single phase and three phase power transformer up to 500MVA. The

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION October 2014 TECHNICAL DESCRIPTION 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES I. SCOPE This

More information

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA MSR Series Modular Series Resonant Systems - 250...2200kV; kva...60,000kva The MSR Series is designed to provide power for FEATURES tests on cables, HV and EHV transformers, gasinsulated switchgear, bushings,

More information

Cast resin transformers HARMONY TM

Cast resin transformers HARMONY TM Cast resin transformers HARMONY TM HARMONY TM the optimum solution for higher performance At a time when we are all seeking to preserve our way of life, the production of equipment whilst ensuring safety

More information

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer PART 1: GENERAL 1.01 Transformer A. This section includes liquid filled, pad mounted distribution transformers with primary voltage of 12kV or 4.16kV (The University will determine primary voltage), with

More information

VI 3 - i TABLE OF CONTENTS

VI 3 - i TABLE OF CONTENTS VI 3 - i TABLE OF CONTENTS 3 PROJECT SPECIFIC DATA... 1 3.1 DEFINITIONS... 1 3.1.1 Design Data, High and Medium Voltage... 1 3.1.2 Design Data, Low Voltage Equipment... 2 3.1.3 Phase Relationship... 3

More information

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELECTRICAL ENGINEERING DIVISION Distribution Network Department SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS ELA T150.2 en SRA 2250/6 Resistor specification The SRA 2250/6 Resistor is intended to increase

More information

PCTS Series. Power Capacitor Test System. Applications: Testing Applications: Benefit and Advantage: and IEC

PCTS Series. Power Capacitor Test System. Applications: Testing Applications: Benefit and Advantage: and IEC PCTS Series Power Capacitor Test System Applications: 12kV/2500kVar and Below Dry and Oil Filled Power Capacitor (Samgor also can special design for customer.) Testing Applications: Capacitance and Tan

More information

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6

MSR Series. Modular Series Resonant Systems kV; 500kVA...60,000kVA FEATURES BENEFITS APPLICATIONS 1/6 MSR Series Modular Series Resonant Systems - 250...2200kV; 500kVA...60,000kVA The MSR Series is designed to provide power for tests on cables, HV and EHV transformers, gasinsulated switchgear, bushings,

More information

CVVOZE Power Laboratories (CVVOZEPowerLab)

CVVOZE Power Laboratories (CVVOZEPowerLab) CVVOZE Power Laboratories (CVVOZEPowerLab) BRNO, SEPTEMBER 2016 1 Centre for Research and Utilization of Renewable Energy Centre for Research and Utilization of Renewable Energy (CVVOZE) was established

More information

MEDIUM & HIGH VOLTAGE

MEDIUM & HIGH VOLTAGE MEDIUM & HIGH VOLTAGE TESTING EQUIPMENT VOLTAGE WITHSTAND SGM Series Resonant Systems The SGM series are used for generating high AC voltages at a fixed frequency (mainly 50 or 60 Hz) by means of an excited

More information

Generation of Sub-nanosecond Pulses

Generation of Sub-nanosecond Pulses Chapter - 6 Generation of Sub-nanosecond Pulses 6.1 Introduction principle of peaking circuit In certain applications like high power microwaves (HPM), pulsed laser drivers, etc., very fast rise times

More information

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP) Discipline Engineering Standard NSW Category Electrical Title Substation Auxiliary Transformer from Rectifier Transformer Secondary Reference Number PDS 01 (RIC Standard: EP 05 00 00 01 SP) Document Control

More information

Substation Preventive Maintenance

Substation Preventive Maintenance Substation Preventive Maintenance PROVINCIAL ELECTRICITY AUTHORITY 1 Presentation Contents 1) A kind of substation 2) Electrical equipment details of AIS substation 3) Electrical equipment details of GIS

More information

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1 Post: Last Amended on - Page 1 of 6 LOCATION 1 I. TRANSFORMERS AND REACTORS 1. 500 MVA, 765 kv 500 MVA, 400 kv Ratio & Polarity Check Magnetic Balance & Magnetizing Current Measurement at Low Voltage Vector

More information

AC Dielectric Test Systems

AC Dielectric Test Systems AC Dielectric Test Systems Phenix Technologies offers a complete line of the most advanced AC Dielectric Test Systems with voltage and power ratings to meet your testing requirements. CABLE GIS CIRCUIT

More information

IEC/CIGRE UHV Symposium Beijing Paper 4.2. Challenges on the measuring and testing techniques for UHV AC and DC equipment

IEC/CIGRE UHV Symposium Beijing Paper 4.2. Challenges on the measuring and testing techniques for UHV AC and DC equipment IEC/CIGRE UHV Symposium Beijing 2007-07-23 Paper 4.2 Challenges on the measuring and testing techniques for UHV AC and DC equipment E. GOCKENBACH 1 ; W. HAUSCHILD 2, S. SCHIERIG 2, M. MUHR 3, W. LICK 3,

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Insulation Test System

Insulation Test System Component Tests Insulation Test System Brief Overview of Phenomena............... 2 Applicable Standards................... 3 Test System Overview.................. 3 Generator Specifications.................

More information

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers KNOW MORE ABOUT THE TRANSFORMERS Glossary Transformers Ambient temperature The existing temperature of the atmosphere surrounding a transformer installation. Ampere The practical unit of electric current.

More information

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA) 0.415/33kV DESIGN AND CONSTRUCTION General 1. The transformer shall be three phase, oil immersed type, air cooled, core type, outdoor

More information

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test A new standard for Hipot & Insulation resistance testing Applied to World-Wide input voltage TOS5301 TOS5300 TOS5302 TOS5300(ACW) TOS5301(ACW/DCW) TOS5302(ACW/IR) New low-cost standard model that provides

More information

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) DELHI METRO RAIL CORPORATION LIMITED DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW) SPECIFICATION NO. DMES- 0005/ DMRC-E-TR-TRANSF-05 SPECIFICATIONS FOR THREE PHASE 33 kv/415 V AUXILIARY Issued on: Date

More information

SGM series. AC Resonant Test System. Applications & Advantages

SGM series. AC Resonant Test System. Applications & Advantages SGM series AC Resonant Test System insulated switchgear (GIS), but also large rotating machines, instrument and power transformers (for applied voltage tests). Resonant test systems enable not only HVAC

More information

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA

IN ELECTRICAL ENGINEERING - I C M E T CRAIOVA Taking into account that power transformer is the major item of equipment in power systems, its correct operation is vital to system operation. It is well known that transformer failures are sometimes

More information

SPAE 010, 011 High Impedance Protection Relay

SPAE 010, 011 High Impedance Protection Relay SPAE 010, 011 High Impedance Protection Relay User s manual and Technical description f n = 50/60 Hz U n = 50 / 100 / 200 V 2 5 U REF > SPAE 010 0.8 U aux 0.6 1.0 RESET OK x 80... 265 V ~ _ 0.4 U > U n

More information

Ohmic Voltage Sensor GSER 16

Ohmic Voltage Sensor GSER 16 Ohmic Voltage Sensor GSER 16 including Isolating Amplifier EGIW 804 AV Medium Voltage Applications Direct, Alternating and Mixed Voltages Wide Frequency Range Electrical Isolation Ohmic Voltage Sensor

More information

Stabilized Differential Relay SPAD 346. Product Guide

Stabilized Differential Relay SPAD 346. Product Guide Issued: July 1998 Status: Updated Version: D/21.03.2006 Data subject to change without notice Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS High voltage shunt capacitor banks Alstom Grid high voltage shunt capacitor bank offering is divided in: By bank construction HV open rack capacitor banks HV enclosed capacitor banks By bank design HV

More information

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment T/3000 Substation Maintenance and Commissioning Test Equipment MULTI FUNCTION SYSTEM FOR TESTING SUBSTATION EQUIPMENT SUCH AS: CURRENT, VOLTAGE AND POWER TRANSFORMERS, ALL TYPE OF PROTECTION RELAYS, ENERGY

More information

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Neutral Earthing. For permanent or temporary neutral earthing in HV systems Neutral Earthing Resistors RESISTORS For permanent or temporary neutral earthing in HV systems For continuous or temporary low-resistance neutral grounding in medium voltage systems Neutral point connection

More information

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA

4Q POWER AMPLIFIERS AC AND DC 3000VA 3x3000VA PERFORMANCES High accuracy High stability Fast transients High inrush current facilities Wide bandwidth 25 khz at -3dB Internal waveform DC and up to 10 khz Very low distortion Quadrant change without

More information

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5

Contents. Measurement and checking equipment for transformation centers Micro-ohmmeter MH-10 Page 3. Indirect earth contact simulator TL-5 Page 5 Measuring and testing equipments P 6 P.6.01 GB for substations Micro-ohmmeter MH-10 Page 3 Mega-ohmmeter MI (5, 10, 15, 20 kv) Page 4 MD (5 kv) Page 4 Indirect earth contact simulator TL-5 Page 5 Indirect

More information

I -limiter The world s fastest switching device

I -limiter The world s fastest switching device I S -limiter 2 I S -limiter The world s fastest switching device Reduces substation cost Solves short-circuit problems in new substations and substation extensions Optimum solution for interconnection

More information

Power Engineering II. High Voltage Testing

Power Engineering II. High Voltage Testing High Voltage Testing HV Test Laboratories Voltage levels of transmission systems increase with the rise of transmitted power. Long-distance transmissions are often arranged by HVDC systems. However, a

More information

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS. This document may be subject to changes. Contact ARTECHE to confirm the characteristics and availability of the products

More information

Reprint E Two Years of Experience with a Mobile Resonant Test System for Testing of Installed Medium- and High Voltage Power Cables

Reprint E Two Years of Experience with a Mobile Resonant Test System for Testing of Installed Medium- and High Voltage Power Cables Two Years of Experience with a Mobile Resonant System for ing of Installed Medium- and High Voltage Power Cables P. Schikarski M. Gamlin J. Rickmann P. Peeters P. v.d. Nieuwendijk R. Koning Reprint ISH

More information

Zürcherstrasse 70 -CH 8104 Weiningen Tel Fax P.O. Box 155 Switzerland

Zürcherstrasse 70 -CH 8104 Weiningen Tel Fax P.O. Box 155 Switzerland Zürcherstrasse 70 -CH 8104 Weiningen Tel. + 41 44 750 63 63 Fax + 41 44 750 63 66 P.O. Box 155 Switzerland www.prescoag.com info@prescoag.com Table of contents 1 Safety precautions 1.1 Safety 1.2 Safety

More information

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24 LECTURER-24 GENERATION OF HIGH ALTERNATING VOLTAGES When test voltage requirements are less than about 300kV, a single transformer can be used for test purposes. The impedance of the transformer should

More information

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD. Our Ref : 2/2018- Date : Messrs: Dear Sir, Tender 2/2018 Main Transformers You are kindly requested to quote for the supply and delivery DDP to our stores the transformers detailed in the attached schedules

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION TECHNICAL DESCRIPTION A.M. BROADCAST TRANSMITTER SENDER AM 3000 SS June 2001-1- Rev. B TRANSMITTER CHARACTERISTICS 1. BASIC OFFER The basic offer includes: One AM3000SS A.M. Medium Wave Solid State Broadcast

More information

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4

INDEX. Micro-ohmmeter MH-10 Page 3. MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Micro-ohmmeter MH-10 Page 3 MI (5, 10, 15, 20 kv) Page 4 Mega-ohmmeter MD (5 kv) Page 4 Earth resistance meter TL-5 Page 5 Indirect earth contact simulator MPC (5, 20, 50 A) Page 6 Trip time tester CR

More information

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge The University of New South Wales School of Electrical Engineering and Telecommunications High Voltage Systems ELEC9712 Appendix Partial Discharge Content Introduction Quantities measured Test circuits

More information

Capacitive voltage transformers

Capacitive voltage transformers Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550

More information

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables

Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables 21, rue d Artois, F-75008 PARIS AUCKLAND 2013 http : //www.cigre.org Partial Discharge Measurement and Monitoring on High Voltage XLPE Cables Michael Krüger, Rene Hummel, Stefan Böhler, OMICRON Austria

More information

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound

Africa Utility Week Focus Day Substation Condition Monitoring Benefits of Ultrasound Africa Utility Week Focus Day 2014 Substation Condition Monitoring Benefits of Ultrasound Agenda Review - Substation Condition Monitoring Electrical discharge Types and origin In switchgear Results/consequences

More information

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable: Reclosers NOVA Three-Phase Recloser Functional Specification Guide Functional specification for NOVA three-phase recloser 1. Scope This specification describes the features and ratings of the NOVA recloser.

More information

Capacitive voltage transformers

Capacitive voltage transformers Capacitive voltage transformers Outdoor operation Oil-paper insulated ECF (72 550) kv General description Capacitive voltage transformers of type ECF are used in high-voltage switchgears from 72 to 550

More information

SPAD 346 C Stabilized differential relay

SPAD 346 C Stabilized differential relay SPAD 346 C Stabilized differential relay Stabilized Differential Relay Type SPAD 346 C Features Integrated three-phase differential relay, three-phase overcurrent relay and multiconfigurable earth-fault

More information

Fixed Series Compensation

Fixed Series Compensation Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and

More information

V P N. Voltage transducer DVM 4200 = 4200 V

V P N. Voltage transducer DVM 4200 = 4200 V Voltage transducer DVM 42 N = 42 V For the electronic measurement of voltage: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit. Features Bipolar and insulated measurement

More information

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

FGJTCFWPKPUVKVWVGQHVGEJPQNQI[ FGRCTVOGPVQHGNGEVTKECNGPIKPGGTKPI VGG246JKIJXQNVCIGGPIKPGGTKPI FGJTFWP"KPUKWG"QH"GEJPQNQI[" FGRTOGP"QH"GNGETKEN"GPIKPGGTKPI" GG"46"JKIJ"XQNIG"GPIKPGGTKPI Resonant Transformers: The fig. (b) shows the equivalent circuit of a high voltage testing transformer (shown

More information

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER TECHNICAL SPECIFICATION FOR POWER TRANSFORMER NOTE: Vendor to give their offer in line with this data sheet only. Any deviations/additions/deletions shall be brought out in a separate sheet. A TECHNICAL

More information

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137

Comparison of CAN/CSA C88.1, IEEE C /01 & IEC 60137 ITEM Power factor (tanδ) & Capacitance Measurement Dry 1-minute Power frequency with partial discharge measurement CAN/CSA C88.1-96 IEEE C57.19.00/01 IEC 60137 Requirement Requirement Requirement Clause

More information

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION Multi function system for testing substation equipment such as: current, voltage and power transformers, all type of protection relays, energy meters and transducers Primary injection testing capabilities

More information

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL 1 Contents 1. Application... 5 2. meter set... 6 3. BASIC REQUIREMENTS, OPERATIONAL SAFETy... 6 4. installation... 10 4.1. Mounting... 10 4.2. External

More information

Test Report CESI A6/ Approved Page 1. MF Trasformatori s.r.l. - Calcinato (BS) Italy

Test Report CESI A6/ Approved Page 1. MF Trasformatori s.r.l. - Calcinato (BS) Italy A6/028659 Test Report CESI Approved Page 1 Client MF Trasformatori s.r.l. - Calcinato (BS) Italy Tested equipment Non-enclosed three-phase dry-type power transformer with three windings, with encapsulated

More information

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manual

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

ODEN AT Primary Current Injection Test System

ODEN AT Primary Current Injection Test System ODEN AT Most Advanced Primary Current Injection Test System to simplify all types of switchgear and CT commissioning, ground grid, circuit breaker testing and more Modular design to permit optimal user

More information

Power IT LV Active Filters PQFA - PQFL - PQFT

Power IT LV Active Filters PQFA - PQFL - PQFT Power IT LV Active Filters PQFA - PQFL - PQFT The ABB comprehensive solution for active filtering of harmonics Pst Harmonics and Power Quality Harmonics caused by non-linear electrical loads such as variable

More information

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS

TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) S. No. PARTICULARS BHEL SPECIFICATIONS TECHNICAL SPECIFICATIONS for 300KV CONSTANT POTENTIAL X RAY EQUIPMENT (for industrial applications) BIDDER s OFFER S. No. PARTICULARS BHEL SPECIFICATIONS 1.0 Area of Application The 300kV Constant potential

More information

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation

GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation GIS Instrument Transformers: EMC Conformity Tests for a Reliable Operation in an Upgraded Substation W. Buesch 1) G. Palmieri M.Miesch J. Marmonier O. Chuniaud ALSTOM LTD 1) ALSTOM LTD High Voltage Equipment

More information

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1 GENERAL: The scope of this document is to provide instruction for the installation and testing of Medium Voltage, 3 Phase, Pad Mounted Transformers installed at the University of Missouri. Preferred transformers

More information

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000 STS 4000 Multifunction substation maintenance & commissioning test system for current, voltage and power transformers. Capacitance / Tan Delta diagnostic system with the optional module TD 5000. w w w.

More information