Sicherheit, auf die Sie sich verlassen können

Size: px
Start display at page:

Download "Sicherheit, auf die Sie sich verlassen können"

Transcription

1 Explosion protected linear light fittings SERIES Sicherheit, auf die Sie sich verlassen können LL 48 Ex Linear LED Explosion protected linear light fitting with LED technique

2 Linear light fitting with high-power LED (Zone 2,21, 22) The linear lighting solution for harsh and hazardous applications luminaires are designed to withstand the harshest conditions within gas Ex areas Zone 2 and dust Ex areas Zone 21 and 22, providing ideal solutions for a wide range of applications. With its rated luminous flux up to 8000 lm the LL48 is suitable for applications where high light output is required, comparable to a 2 x 58 W fluorescent light fitting. combines a shock and vibration resistant luminaire with the low cost of ownership and energy efficiency of the Crouse-Hinds Series LED technology. High-performance LEDs and a solid-state electronic driver provide light where you need it, at a fraction of the operating costs of conventional lighting technologies. Different types for any application: The LL 48 Ex Linear LED is available in two versions for different applications: Linear light fitting and Linear light fitting with self-contained battery system (type EM). EM light fittings with self-contained battery are available with different emergency light functions: EM1 with emergency lighting duration of 3 hours and 35 % luminous flux; EM2 with emergency lighting duration of 2 hours and 50 % luminous flux. All luminaires can be delivered with clear (-C-) or opaque (-F-) protective cover. Features Linear light fitting for normal lighting and with self-contained battery for emergency lighting (type EM) Immediate start, instant full illumination No lifetime reduction due to switching cycles High efficient and energy saving up to 42 % Superb safety and reliability, robust construction Protective cover in clear or opaque impact resistant glass Wide temperature range and a brilliant optical performance for a wide application range Mercury-free and environment-friendly High degree of protection IP66 2 EATON S CROUSE-HINDS BUSINESS

3 Ordering details Ordering details Type Power consumption Thread LL48 5L... (5000 lm) emergency lighting with opaque cover Protective cover Emergency duration Luminous flux in emergency mode Order No. LL48-5L-7/-F-1M-EM1 W 1 x M20 opaque 3 h 35 % CCL A LL48-5L-7/-F-1M-EM2 W 1 x M20 opaque 2 h 50 % CCL A LL48-5L-7/-F-1M-EM1-S886 W 2 x M20 opaque 3 h 35 % CCL A LL48-5L-7/-F-1M-EM2-S886 W 2 x M20 opaque 2 h 50 % CCL A LL48 6L... (00 lm) emergency lighting with clear cover LL48-6L-7/-C-1M-EM1 W 1 x M20 clear 3 h 35 % CCL A LL48-6L-7/-C-1M-EM2 W 1 x M20 clear 2 h 50 % CCL A LL48-6L-7/-C-1M-EM1-S886 W 2 x M20 clear 3 h 35 % CCL A LL48-6L-7/-C-1M-EM2-S886 W 2 x M20 clear 2 h 50 % CCL A LL48 7L... (7000 lm) with opaque cover LL48-7L-7/-F-1M W 1 x M20 opaque - CCL A LL48-7L-7/-F-1M-S886 W 2 x M20 opaque - CCL A LL48 8L... (8000 lm) with clear cover LL48-8L-7/-C-1M W 1 x M20 clear - CCL A LL48-8L-7/-C-1M-S886 W 2 x M20 clear - CCL A Scope of delivery without fixing accessories Mounting accessories Type Ceiling/wall mounting brackets and pipe clamps Order No. Ceiling mounting brackets D 92 with screws and polyamide washer, stainless steel, 2 pcs Wall mounting brackets with angle, hot-dip galvanized, 2 pcs Pipe clamps R12 (1 1/4 ) Ø mm with screws and polyamide washer, hot-dip galvanized Pipe clamps R12 (1 1/2 ) Ø mm with screws and polyamide washer, hot-dip galvanized EATON S CROUSE-HINDS BUSINESS 3

4 Technical Data / Dimension drawing Technical data Type Examination Certificate ITS ATEX X IECEx Certificate of conformity IECEx CQM X Marking accd. 94/9/EC D II 3G Ex na IIC T... Gc D II 2D Ex tb IIIC T80 C Db Marking accd. to IECEx Ex na IIC T... Gc 40 C, 55 C) Ex tb IIIC T80 C Db Permissible ambient temperature -40 C up to +55 C / -25 C up to +55 C (type EM) Rated voltage V AC / V AC (type EM) Frequency 50 - Hz Power consumption up to W / up to W (type EM) Power factor cos 0.9 Protection class I Light colour / CRI 5700 K (CRI 70) Lamp / Illuminant LED Rated luminous flux 5000 lm (5L) / 00 lm (6L) / 7000 lm (7L) / 8000 lm (8L) Dimensions (L x W x H) 1041 x 200 x 100 mm Connecting terminals L, N, PE / L, L1, N, PE (type EM) max. 2 x 6mm 2 per terminal Enclosure material Copper-free aluminium Weight 11 kg / 13 kg (type EM) Degree of protection accd. to EN 529 IP66 Cable glands / gland plates / 1 x M20 or 2 x M20 thread enclosure drilling Battery (only type EM) 12 NC battery, 5.0 Ah Rated emergency lighting duration 3 h (EM1) / 2 h (EM2) Luminous flux in emergency operation 35 % (EM1 single line) / 50 % (EM2 single line) Lifetime of the light fitting 120, C /, C Protective cover / protective bowl Tempered impact resistant glass (clear and opaque) Dimension drawing LL48 Ex LED X 2 up to Dimensions in mm X = fixing dimensions 4 EATON S CROUSE-HINDS BUSINESS

5 Polar curve LL 48 Ex Linear LED Polar curve LL48 Ex LED LL48 opaque cover LL48 clear cover C 0 C l/cd/klm C 0 C l/cd/klm EATON S CROUSE-HINDS BUSINESS 5

6 Eaton s Crouse-Hinds Business The safety you rely on. See the complete offering of Hazardous and Industrial Products at U.S. (Global Headquarters): Eaton's Crouse-Hinds Business 1201 Wolf Street Syracuse, NY (866) FAX: (3) FAX Orders Only: (866) CrouseCustomerCTR@Eaton.com For more information: If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department. Australia Phone Fax crousehindsanz@eaton.com China Phone Fax ECHsales@eaton.com Great Britain Phone Fax sales5@eaton.com India Phone Fax cchindia@eaton.com Canada Toll Free Fax Fax orders only: Korea Phone Fax CCHK-sales@eaton.com Mexico/Latin America/ Caribbean Phone Fax ventascentromex@eaton.com Spain Phone Fax sales.cch.es@ cooperindustries.com Middle East (Dubai) Phone / 2500 Fax CHMEsales@eaton.com The Netherlands Phone Fax CHRD_mail@eaton.com Norway Phone Fax CHLIoffice@eaton.com Singapore: Phone Fax CHSI-Sales@eaton.com Turkey Phone Fax infoegturkey@eaton.com Russia Phone Fax info@cooper.ru.com Eaton s Crouse-Hinds Business Neuer Weg Nord 49 D Eberbach Phone +49 (0) 6271/ Fax +49 (0) 6271/ info-ex@eaton.com Internet Eaton 1000 Eaton Boulevard Cleveland, OH United States Eaton.com Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. 20 Eaton Corporation All Rights Reserved Printed in Germany Publication No. BR #### May 20 Eaton s Crouse-Hinds Business 1201 Wolf Street Syracuse, NY (866) CrouseCustomerCTR@Eaton.com Eaton is a registered trademark. All other trademarks are property of their respective owners.

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können CEAG Products Ex-emergency lighting CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Explosion protected safety luminaire for Zone 1/2 und 21/22 Explosion protected safety luminaire Zone

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk Ex-Linear Light Fitting Linear Light Fitting with LED Tubes

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk LED / nllk V-CG-S LED DALI Ex-Linear Light Fittings Linear

More information

Sicherheit, auf die Sie sich verlassen können

Sicherheit, auf die Sie sich verlassen können Explosion protected linear light fittings CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Ex-Linear LED Light Fittings for Zone 2/22 Ex-Linear LED Light Fittings Linear LED Light Fittings

More information

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights

CROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED

More information

Hazardous area LED lighting Pauluhn Summit linear LED luminaires. Pauluhn Summit. Linear, high bay LED luminaires designed for hazardous areas

Hazardous area LED lighting Pauluhn Summit linear LED luminaires. Pauluhn Summit. Linear, high bay LED luminaires designed for hazardous areas Hazardous area lighting Pauluhn linear luminaires Pauluhn Linear, high bay luminaires designed for hazardous areas Pauluhn Safe. Reliable. Efficient. Featuring the industry's broadest range of luminaires

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant

More information

Ex-control switch Typ 294 without and Typ 295 with measuring instrument

Ex-control switch Typ 294 without and Typ 295 with measuring instrument Ex-control switch GHG 9 and GHG 9 GHG 9 GHG 9 Technical data Ex-control switch Typ 9 without and Typ 9 with measuring instrument with GHG 9 switch with GHG switch Marking accd. to 0//EU D II G Ex ed ia

More information

J: Emergency lighting (optional) L: pole type X: ceiling type

J: Emergency lighting (optional) L: pole type X: ceiling type Lighting Technology Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone and Zone Zone and Zone

More information

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations.  EATON 2.4.1 CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

2.19. Fixing systems for installing luminaires. Complete systems and single components

2.19. Fixing systems for installing luminaires. Complete systems and single components .19 for installing luminaires Complete systems and single components The one-off manufacture of individual assembly systems for installing lighting systems is often very costly. The patented Complete ssembly

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Multiturn absolute encoder

Multiturn absolute encoder 0102 Model Number SYNCHRON SERIELLES INTERFACE Features Up to 30 Bit multiturn ATEX approval IECEx approval Flameproof enclosure Removable connection cap Galvanically isolated RS 22 interface Description

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome

TECHNICAL SHEET. Outdoor architectural projector RONDO-01 9LED. About the product. RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome No. 352 / 02.12.2014, Edition No. 9, 1/5 Outdoor architectural projector RONDO-01 9LED RONDO-01 9x1W LED RGB, RONDO-01 9x1W LED monochrome About the product The RONDO-01 LED projector is designed for architectural

More information

TECHNICAL DIVISION GALILEO 1 IN Rev. MAR-17

TECHNICAL DIVISION GALILEO 1 IN Rev. MAR-17 Applications Optic Insulation class Protection degree LED Modules Tilt Angle Dimensions Weight Mounting Gear tray Operating temp. Main reference standards GALILEO 1 IN MAIN CHARACTERISTICS Indoor lighting

More information

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.

More information

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office:

E LED Lighting BV & Inc. European Office: Tel: +31 (0) , Fax +31 (0) , E mail LEDLighting.com United States Office: HIGH POWER LED LIGHTS LED Flood Lights LED Floodlights operate efficiently and save power but also reduce maintenance and service costs as a result of their long life. Conventional floodlights require

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ET Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors ET Analog High operating temperature Compact sensor housing ATEX / IECEx / CEC / NEC certified MEASURING TECHNOLOGY The absolute, linear position sensors

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

iant101 Zone 1 Omni Directional Antenna

iant101 Zone 1 Omni Directional Antenna iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60

More information

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11

Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 Electronic pressure measurement Pressure transmitter with flameproof enclosure For applications in explosion-protected areas Models E-10 and E-11 WIKA data sheet PE 81.27 for further approvals see page

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

RE 2 Post Rack System

RE 2 Post Rack System Installation Guide RE 2 Post Rack System 1 TABLE OF CONTENTS SAFETY WARNINGS Frame Assembly Guide 4-6 Vertical Cable Manager Assembly Guide 7 + 8 Adjustable Cable Spools 9 + 10 Vertical Cable Basket 11

More information

Technical Application Guide for UP-SHINE LED Linear

Technical Application Guide for UP-SHINE LED Linear Technical Application Guide for UP-SHINE LED Linear UP-DB9-6-12W-S UP-DB9-6-12W-E Introduction DB9 LED Linear is mainly designed for Oceania and European market, 2835 high lumen SMD LED chip been used

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Load cell. Special features. Data sheet

Load cell. Special features. Data sheet Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to

More information

2.4G. wireless transmission technology. Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-AW

2.4G. wireless transmission technology. Technical Application Guide for UP-SHINE LED Ceiling light UP-AL W-AW 2.4G wireless transmission technology Technical Application Guide for UP-SHINE LED Ceiling light UP-AL2-14-25W-AW Introduction 2.4G wireless transmission technology AL2 Oyster LED ceiling light can be

More information

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...

KAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0... Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

SKILL. Wall mounted. Bollard

SKILL. Wall mounted. Bollard SKILL Wall mounted Bollard Skill square 270mm www.simes.it/skill 51 SKILL lighting for surface or flush wall mounting Die-cast EN AB-47100 aluminium (low copper content) housing with high corrosion resistance.

More information

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet Temposonics ostrictive Linear Position Sensors TH SSI ATEX / IECEx / CEC / NEC / EAC Ex certified / Japanese approval Continuous operation under harsh industrial conditions Flameproof / Explosionproof

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

CrystalWay Emergency lighting luminaires Product Brochure. Safety with total transparency

CrystalWay Emergency lighting luminaires Product Brochure. Safety with total transparency CrystalWay Emergency lighting luminaires Product Brochure Safety with total transparency CrystalWay Safety with total transparency CrystalWay is a new range of self-contained units and aesthetic evacuation

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

GE LED Edgelit Panel. PREMIUM version. GE Lighting DATA SHEET. Product information. Features and Benefits. Application areas

GE LED Edgelit Panel. PREMIUM version. GE Lighting DATA SHEET. Product information. Features and Benefits. Application areas GE Lighting GE LED Edgelit Panel PREMIUM version DATA SHEET IP40 CLASS II Product information GE LED luminaires transform ambient lighting into an exquisite balance of refined appearance and superior efficiency.

More information

2-channel speed sensor GEL 247 Compact sensor for harsh applications

2-channel speed sensor GEL 247 Compact sensor for harsh applications 2-channel speed sensor GEL 247 Compact sensor for harsh applications Technical information Version 01.11 General Speed sensor based on magnetic measurement principle Maintenance- and wear-free operation

More information

Absolute Encoders - Singleturn

Absolute Encoders - Singleturn The Sendix 5853 and Sendix 5873 singleturn encoders with SSI or BiSS interface and optical sensor technology can achieve a resolution of max. 7 bits. These encoders are also available with an optional

More information

CE620. Piezoelectric accelerometer with integrated electronics. IECEx

CE620. Piezoelectric accelerometer with integrated electronics. IECEx Piezoelectric accelerometer with integrated electronics FEATURES» From the Vibro-Meter product line» Voltage output signal: 100 or 500 mv/ g» Frequency response: 2 Hz to 10 khz» Temperature range: 55 to

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

HEAVY DUTY 800 SERIES ENCODER MODELS 841, 850, 855, 861, 862, 865

HEAVY DUTY 800 SERIES ENCODER MODELS 841, 850, 855, 861, 862, 865 HEAVY DUTY 800 SERIES ENCODER MODELS 841, 850, 855, 861, 862, 865 Robustness and reliability Are you looking for the most robust, maintenance-free and cost-effective encoder? Then the 800 series is for

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Mount MLX2. Base plate MLX3

Mount MLX2. Base plate MLX3 distributed in Qld by Mount MLX2 Base plate MLX3 Spike MLX4 MINIATURE LED MARKER LIGHT The range of sub-miniature luminaires offer a decorative yet functional pixel for your lighting design. Its robust

More information

Technical Application Guide for OMEGA LED Ceiling light

Technical Application Guide for OMEGA LED Ceiling light Technical Application Guide for OMEGA LED Ceiling light AL8-14-25W-P3 WW NW CW Introduction Color changeable LED ceiling light adopts high lumen SMD LED, fire-rated PC light housing and diffuser with even

More information

Technical Application Guide for UP SHINE LED T8 Batten UP-AL06-9W-BO-M

Technical Application Guide for UP SHINE LED T8 Batten UP-AL06-9W-BO-M Technical Application Guide for UP SHINE LED T8 Batten UP-AL6-9W-BO-M Introduction T8 diffused batten suitable for ceiling, wall or pendant mounting. Prismatic diffuser for visual comfort. Cover plate

More information

T-Line, current transformers

T-Line, current transformers Type HF, primary current up to 5000 amps, accuracy classes from 0.2S to 3, highest system voltage 720 volt T-Line, current transformers Catalogue 208 . Table for contents...2 2. Description Current transformers

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

OPTIWAVE 1010 Technical Datasheet

OPTIWAVE 1010 Technical Datasheet OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator

More information

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a The Heavy Duty incremental encoder type 0H boasts a high degree of ruggedness in a very compact design. Its special construction makes it perfect for all applications in very harsh environments. / RoHS

More information

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. ER Analog Data Sheet Temposonics Magnetostrictive Linear Position Sensors ER Analog Compact sensor model Operating temperature up to +75 C (+167 F) Ideal for flexible mounting MEASURING TECHNOLOGY The absolute, linear position

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

PV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line

PV 102. IECEx. Piezoelectric velocity sensor FEATURES. From the Vibro-Meter product line FEATURES From the Vibro-Meter product line Designed for medium temperature industrial applications: 50 to +120 C ( 58 to +248 F) Frequency response: 6.0 to 2500 Hz: ±10 % to 5000 Hz: ±3 db Ultra low-noise

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Temposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified

Temposonics. Magnetostrictive Linear Position Sensors. ET Start/Stop Data Sheet. High operating temperature Compact sensor housing ATEX certified Temposonics Magnetostrictive Linear Position Sensors ET Start/Stop High operating temperature Compact sensor housing ATEX certified The Measurable Difference Temposonics ET Start/Stop MEASURING TECHNOLOGY

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

Beamer Floodlight LED IP 65

Beamer Floodlight LED IP 65 3 6666 4 205 3 6666 4 160 283 466663 4666663 336 153 666666 36664 LED 0q p C IP 65 Graphit m LED 36W 3780lm 3000K warm white Switchable Version 5 Spherolit lens, wide flood Product description Housing,

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations

Areamaster Generation 2 HL LED Luminaire Floodlight for Hazardous Locations Areamaster Generation HL LED Luminaire Class I, Division, Groups A, B, C, D Class I, Zone Group IIC Class II, Division and, Groups E, F, G Zone and Group IIIC Zone, Group IIIB Type R,, X, IP66/67 Applications

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information