Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
|
|
- Deborah Shields
- 6 years ago
- Views:
Transcription
1 9165/ s Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used up to SIL 2 (IEC/EN 61508) WebCode 9165A 9165 series Ex i isolating repeaters can be used for the intrinsically safe operation of control valves, I/P transducers or indicators. They transmit superimposed HART communication signals in both directions. The input, output and auxiliary power are galvanically separated from one another. The two channels in the two-channel variants are galvanically separated from one another. Technical Data Explosion Protection Application range (Zone) 2 22 Ex interface zone Certificate IECEX Gas Certificate ATEX Gas Certificate IECEX Dust Certificate ATEX Dust Gas explosion protection IECEx Gas explosion protection ATEX Dust explosion protection IECEx Dust explosion protection ATEX Certificates Ship approval IECEx BVS X BVS 10 ATEX E 025 X IECEx BVS X BVS 10 ATEX E 025 X Ex na nc [ia Ga] IIC T4 Gc II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC II (1) D [Ex ia Da] IIIC ATEX, Canada (CSA), Corea (KCs), EAC (TR), FMEDA-Report (EXIDA), IECEx, Russia (GOST-R), USA (FM) CCS, DNVGL SIL 2 Installation in Division NEC 500 (Class I, II, III) 2 Ex interface in Division NEC 500 (Class I, II, III) 1, 2 Selection Table Safety-related max. voltage Max. Voltage U o Max. Current I o Max. Demand P o 253 V V 96.0 ma mw R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D Waldenburg 1/5
2 9165/ s Electrical Data Nominal voltage Nominal current Power input Power input_w 24 V DC ma 1.30 VA 1,3 W Number of channels 1 Output Input input signal Max. load resistance RL Load resistance R L Auxiliary power LFD relay output signal Auxiliary power voltage range Input functional range Input resistance Output functional range 0/4-20 ma with HART Ω Ohm 24 V DC No ,2 V 4-24 ma 400 Ω ma Output settling time 100 µs Polarity reversal protection Residual ripple voltage range Electromagnetic compatibility yes 3,6 VSS Tested to the following standards and regulations: EN Use in industrial environment Ambient Conditions Min. ambient temperature -20 C Min. ambient temperature note Single device Max. ambient temperature +70 C Max. ambient temperature note Single device Min. ambient temperature2-20 C Min. ambient temperature note2 Group assembly Max. ambient temperature2 +60 C Max. ambient temperature note2 Group assembly Min. storage temperature -40 C Max. storage temperature +80 C Max. relative humidity 95 % Usage on high max. 2,000 m Mechanical Data Gross weight kg Mounting Installation Mounting type Connection type rail (NS35/15, NS35/7,5) Screw terminal R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D Waldenburg 2/5
3 9165/ s Technical Drawings aaus aa a aa s pac-bus s c pac sa ss Connection Diagram Dimensional Drawings (All Dimensions in mm [inch]) - Subject to Alterations X 99 [ 3, 90 ] 17,6 [0,69] 114,5 [ 4, 51 ] 122 [ 4, 80 ] Dimension X Screw terminals 108 mm / 4.25 Spring clamp terminals 128 mm / 5.04 Accessories and Spare Parts DIN rail NS 35 / 15 (meter length) DIN-Rail (EN ) NS 35 / 7.5 (meter length) R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D Waldenburg 3/5
4 9165/ s Front cover yellow, transparent. Clear marking of the device for SIL applications. (Packaging unit: 10 pieces) ISpac Dummy-Module The Dummy module is used for the connection of unused cable. There is no electrical connection between input and output terminal Screw terminal black blue green Screw terminal with test plug socket black blue Spring clamp terminal black blue green R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D Waldenburg 4/5
5 9165/ s We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding R. STAHL Schaltgeräte GmbH Am Bahnhof 30 D Waldenburg 5/5
Isolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationEngineering Guideline. pac-carriers Type for Yokogawa Centum VP
Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationSignal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More informationAssembly. Front view. HiC2441. SL2 1b. Termination Board
SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationTechnical Information Barrier RB223
TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES
ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50
Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationTemperature transmitter itemp RTD DIN rail TMT 127
Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,
More informationLighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp
Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationD1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:
Characteristics: Front Panel and Features: Ordering Information: Model: D7 D7 General Description: The single and dual channel DIN Rail Temperature Signal Converter D7S and D7D accepts a low level dc signal
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationLevel Limit Switch nivotester FTL 325 P
Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit
More informationitemp HART DIN rail TMT112
Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction
More informationAssembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II
Switch Amplifier Features Assembly -channel isolated barrier 5 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC 6508/EC
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency
More informationMACX MCR-EX-SL-RPSSI-I-UP(-SP)
Supply and input signal conditioner, Ex-i, with wide range supply Data sheet 103561_en_00 PHOENIX CONTACT 2014-08-19 1 Description The MACX MCR-EX-SL-RPSSI-I-UP(-SP) repeater power supply and input signal
More informationâ itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring
Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a
More informationAssembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationRemote Switching Unit nivotester FTL 320
Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationSINEAX / EURAX 2I1 Passive DC signal isolator
SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages
More informationTemperature Measurement
Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationSINEAX TV809, 1 channel Programmable Isolating Amplifier
For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive) Application-specific outputs Line fault transparency
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More information58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4
58 58 3 & 4 CO relay interface modules, 31 mm wide with Push-in terminals Ideal interface for PLC and electronic systems 58.P3 58.P4 Type 58.P3 3 CO 10 A Push-in terminals Type 58.P4 4 CO 7 A Push-in terminals
More informationonlinecomponents.com
Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier
Technical Information Nivotester FTR325 1-channel switch amplifier for the Soliwave M microwave barrier Area of application The Nivotester FTR325 is suitable as a 1-channel switch amplifier for the Soliwave
More informationTechnical Information RMA42
TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationDIN Rail Devices. CEAG Sicherheitstechnik GmbH 194
DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationControl Unit Series 8208
> Installation of various components such as Snap action switch Potentiometer Relay Time relay Diodes Fuses Resistors www.stahl.de 01776E00 Components of various functions such as diodes, resistors, fuses
More informationSubmersible pressure sensor For superior applications Model LF-1
Level Submersible pressure sensor For superior applications Model LF-1 WIKA data sheet LM 40.04 Applications Level measurement in vessel and storage systems Overfilling and no-load operation monitoring
More informationTemperature Measurement
Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective
More information