Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp
|
|
- Darcy Underwood
- 5 years ago
- Views:
Transcription
1 Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant pole type D: pendant chain type B: wall type L: pole type Explosion protection to -CENELEC -IEC -NEC Can be used in Zone Zone 1 and Zone Class I, Zone Class I, Division, Groups A, B, C, D Six enclosure types: -Single tube: three enclosure types -Dual tube: three enclosure types Applicable lamp power: Fluorescent lamps: 18W x 1, 36W x 1, 8W x 1 18W x, 36W x, 8W x LED lamps: 9W(1 W ) x 1, 18W (19W) x 1, 8W (W) x 1 9W (1W) x, 18W (19W) x, 8W (W) x Electronic ballast, wide voltage range, rapid starting, stable performance, power factor.9. Only dual tube light fittings with emergency lighting function. End of lamp life (EOL) rectification effect protection. number LED: Only for LED lamp Explosion-proof light fittings for fluorescent lamp Dimension drawings (all dimensions in mm) - subject to alteration BnY81- x 1 BnY81-LED x 1 BnY81- x BnY81-LED x Dimensions Type Size (mm) L Type Size (mm) L BnY81-18x1, BnY81-LED 9x1 68 BnY81-18x, BnY81-LED 9x 68 BnY81-36x1, BnY81-LED 18x BnY81-36x, BnY81-LED 18x BnY81-8x1, BnY81-LED 8x BnY81-8x, BnY81-LED 8x Zones ; 1& /4 General Catalogue
2 Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Technical data Explosion-proof light fittings for fluorescent lamp BnY81- x Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Ballast Exposed fastener brand Rated voltage Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter Emergency data Emergency unit Emergency Emergency start time Charge time Emergency lighting time II 3 G Ex na IIC T4 Gc II D Ex tb IIIC T8 Db IP66 LCIE 1 ATEX 19X (Gas); LCIE 1 ATEX 319X (Dust); IECEx CQM 1.46X FM (USA); GOST.R (Russia) EN 679-: 9, EN 679-1: 1, EN : 9 IEC 679-: 11, IEC 679-1: 1, IEC : 8 Polycarbonate, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact, corrosion-proof Electronic ballast Stainless steel PHILIPS T8 (supplied with the light fittings) 1~3V AC /6Hz IP66 - ~+ 3 x 1.~4mm (L+N+PE) Ceiling type, pendant pole type, pendant chain type, wall type, pole type x Φ1: x M x 1. cable gland (DQM-I Ex e, plastic) Φ6~Φ1 (mm) Special emergency controller and NI-MH battery pile, with protection against over charge and over discharge 18W x 1, 36W x 1, 8W x 1.3s 4h 18W 1 36W 1 8W 1 1min (18min is optional) 18W 36W 8W Selection table BnY81-X 1.6 BnY81-X.7 BnY81-8 x 1X 8 x 1.9 BnY81-G 1.8 BnY81-G.9 BnY81-8 x 1G 8 x BnY81-D 1.9 BnY81-D 3. BnY81-8 x 1D 8 x BnY81-B 1.9 BnY81-B 3. BnY81-8 x 1B 8 x BnY81-L 1.6 BnY81-L.7 BnY81-8 x 1L 8 x 1 3. BnY81-18 x X 18 x. BnY81-36 x X 36 x 3. BnY81-8 x X 8 x 4. BnY81-18 x G 18 x. BnY81-36 x G 36 x 3. BnY81-8 x G 8 x 4. BnY81-18 x D 18 x.3 BnY81-36 x D 36 x 3. BnY81-8 x D 8 x 4.3 BnY81-18 x B 18 x.3 BnY81-36 x B 36 x 3. BnY81-8 x B 8 x 4. BnY81-18 x L 18 x. BnY81-36 x L 36 x. BnY81-8 x L 8 x 4. BnY81-18 x XJ 18 x 3. BnY81-36 x XJ 36 x 4. BnY81-8 x XJ 8 x. BnY81-18 x GJ 18 x 3. BnY81-36 x GJ 36 x 4.4 BnY81-8 x GJ 8 x. BnY81-18 x DJ 18 x 3. BnY81-36 x DJ 36 x 4. BnY81-8 x DJ 8 x. BnY81-18 x BJ 18 x 3.4 BnY81-36 x BJ 36 x 4. BnY81-8 x BJ 8 x.4 BnY81-18 x LJ 18 x 3.1 BnY81-36 x LJ 36 x 4.3 BnY81-8 x LJ 8 x.1 Note: 1. Products above include all the mounting accessories listed in Accessories & Spare Parts Table (see P/9). General Catalogue /
3 Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Photometric data(bny81- x ) 18W x 1 photometric data Rated luminous flux:1lm; Luminous intensity distribution cd/1lm 18W x photometric data Rated luminous flux:1lm; Luminous intensity distribution cd/1lm W x 1 photometric data Rated luminous flux:lm; Luminous intensity distribution cd/1lm 36W x photometric data Rated luminous flux:lm; Luminous intensity distribution cd/1lm W x 1 photometric data Rated luminous flux:lm; Luminous intensity distribution cd/1lm 8W x photometric data Rated luminous flux:8lm; Luminous intensity distribution cd/1lm We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. /6 General Catalogue
4 Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Technical data Explosion-proof light fittings for fluorescent lamp BnY81-LED x Explosion protection Gas explosion protection Dust explosion protection Certificates Conformity to standards Material Enclosure Diffuser Power controller Exposed fastener brand Rated voltage Degree of protection Ambient temperature Terminal Cable entries Available cable outer diameter Emergency data Emergency unit Emergency Emergency start time Charge time Emergency lighting time II 3 G Ex na IIC T4 Gc II D Ex tb IIIC T8 Db IP66 LCIE 1 ATEX 19X (Gas); LCIE 1 ATEX 319X (Dust); IECEx CQM 1.46X FM (USA); GOST.R (Russia) EN 679-: 9, EN 679-1: 1, EN : 9 IEC 679-: 11, IEC 679-1: 1, IEC : 8 Polycarbonate, stands 7J impact, corrosion-proof Polycarbonate, 9% light transmission, stands 7J impact, corrosion-proof Wide voltage input, CC-CV (constant current - constant voltage) output, power factor.98 Stainless steel CREE plural white LED modules (supplied with the light fittings) 9W (1W) 1 18W (19W) 1 8W (W) 1 11~6V AC /6Hz IP66 - ~+ 3 x 1.~4mm (L+N+PE) 9W (1W) 18W (19W) 8W (W) Ceiling type, pendant pole type, pendant chain type, wall type, pole type x Φ1: x M x 1. cable gland (DQM-I Ex e, plastic) Φ6~Φ1 (mm) Special emergency controller and NI-MH battery pile, with protection against over charge and over discharge 9W x 1, 18W x 1, 8W x 1.3s 4h 1min (18min is optional) Selection table BnY81-LED 9 x 1X 9 x 1 1. BnY81- LED X BnY81- LED 9 x 1G 9 x BnY81- LED G BnY81- LED 9 x 1D 9 x 1 1. BnY81- LED D BnY81- LED 9 x 1B 9 x 1 1. BnY81- LED B BnY81- LED 9 x 1L 9 x 1 1. BnY81- LED L BnY81- LED 9 x X 9 x 1.7 BnY81- LED 18 x X BnY81- LED 9 x G 9 x 1.9 BnY81- LED 18 x G BnY81- LED 9 x D 9 x. BnY81- LED 18 x D BnY81- LED 9 x B 9 x. BnY81- LED 18 x B BnY81- LED 9 x L 9 x 1.7 BnY81- LED 18 x L BnY81-LED 9 x XJ 9 x. BnY81- LED 18 x XJ BnY81-LED 9 x GJ 9 x. BnY81- LED 18 x GJ BnY81-LED 9 x DJ 9 x. BnY81- LED 18 x DJ BnY81-LED 9 x BJ 9 x. BnY81- LED 18 x BJ BnY81-LED 9 x LJ 9 x. BnY81- LED 18 x LJ x x x x x x x x x x 3. BnY81-LED 8 x 1X BnY81- LED 8 x 1G BnY81- LED 8 x 1D 8 x 1 8 x 1 8 x 1 BnY81-LED 8 x 1B 8 x 1 BnY81- LED 8 x 1L 8 x 1 BnY81- LED 8 x X 8 x BnY81- LED 8 x G 8 x BnY81- LED 8 x D 8 x BnY81- LED 8 x B 8 x BnY81- LED 8 x L 8 x BnY81- LED 8 x XJ 8 x BnY81- LED 8 x GJ 8 x BnY81- LED 8 x DJ 8 x BnY81- LED 8 x BJ 8 x BnY81- LED 8 x LJ 8 x Note: 1. Products above include all the mounting accessories listed in Accessories & Spare Parts Table (see P/9) General Catalogue /7
5 Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Photometric data(bny81- LED x ) 9W x 1 photometric data Rated luminous flux:94lm; Luminous intensity distribution cd/1lm 9W x photometric data Rated luminous flux:189lm; Luminous intensity distribution cd/1lm W x 1 photometric data Rated luminous flux:189lm; Luminous intensity distribution cd/1lm 18W x photometric data Rated luminous flux:378lm; Luminous intensity distribution cd/1lm W x 1 photometric data Rated luminous flux:9lm; Luminous intensity distribution cd/1lm 8W x photometric data Rated luminous flux:88lm; Luminous intensity distribution cd/1lm We can provide lighting design and data by professional lighting software DIALUX based upon simulated site situation on request. /8 General Catalogue
6 Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent type (all dimensions in mm) - subject to alteration Installation reference D: pendant chain type G: pendant pole type -Φ84 6-Φ1. L 4-Φ1 68 L X: ceiling type B: wall type -Φ1 9 L Φ11 L 3 L: pole type (the pole is provided by user) 8 L 8 L 8 L Φ Φ48 Φ Φ48 Φ Φ48 4-Φ14 Suitable for ground pole type Suitable for fence pole type Suitable for wall pole type accessories and spare parts table Supplied according to the mounting type Accessories type Name Qty Illustration D: pendant chain type G: pendant pole type 1.Sucker 3. bracket See P/6 See P/.Chain 4.M8 Screw Length: 4mm Length: 3mm X: ceiling type B: wall type. bracket 6.Wall bracket See P/6 Welded sheet steel L: pole type 7.G1 1/4 Pipe clamp See P/7 8. bracket See P/7 Note: Accessories not in the table shall be supplied by user. Ordering code S1G1 1S1G B General Catalogue /9
J: Emergency lighting (optional) L: pole type X: ceiling type
Lighting Technology Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone and Zone Zone and Zone
More informationSignal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings SERIES Sicherheit, auf die Sie sich verlassen können LL 48 Ex Linear LED Explosion protected linear light fitting with LED technique Linear light fitting with
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationSicherheit, auf die Sie sich verlassen können
CEAG Products Ex-emergency lighting CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Explosion protected safety luminaire for Zone 1/2 und 21/22 Explosion protected safety luminaire Zone
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More information100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features
C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationiant101 Zone 1 Omni Directional Antenna
iant101 Zone 1 Omni Directional Antenna External Antenna offering increased flexibility for positioning and greatly enhanced RF Propagation. ATEX Ex t IIIC T85 C Db IECEx Ex t IIIC T85 C Db -40 C to 60
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationCROUSE-HINDS. PXLED - Power Floodlight Series for Hazardous Areas SERIES. CEAG Products Explosion protected floodlights
CEAG Products Explosion protected floodlights CROUSE-HINDS SERIES PXLED - Power Floodlight Series for Hazardous Areas Explosion-protected LED floodlight series for Zone 1, 2, 21 and 22 Ex-Floodlight PXLED
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationCable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*
Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationM224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #
Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationMultiturn absolute encoder
0102 Model Number SYNCHRON SERIELLES INTERFACE Features Up to 30 Bit multiturn ATEX approval IECEx approval Flameproof enclosure Removable connection cap Galvanically isolated RS 22 interface Description
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk Ex-Linear Light Fitting Linear Light Fitting with LED Tubes
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationCEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1
CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG
More informationOPTIWAVE 1010 Technical Datasheet
OPTIWAVE 1010 Technical Datasheet Radar (FMCW) Level Transmitter for bypass chambers and magnetic level indicators (BM 26 Advanced) Device welded to a bypass chamber with an optional IP68 level indicator
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Ex-Linear LED Light Fittings for Zone 2/22 Ex-Linear LED Light Fittings Linear LED Light Fittings
More informationLoad cell. Special features. Data sheet
Z6R Load cell Special features - Nominal (rated) loads: 20 kg 200 kg - Welded-on robust cover - Load cells made of rust-resistant materials - Easy to clean - Same dimensions like Z6F - Verifiable up to
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk LED / nllk V-CG-S LED DALI Ex-Linear Light Fittings Linear
More informationDescription of equipment
Applicant: Electrical Apparatus: KROHNE Messtechnik GmbH & Co. KG Level Radar BM 70M-Ex Description of equipment The Types BM 70M-Ex Level Radar gauges serve to continuously measure the product level in
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More informationSOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS
SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationLevel Measurement Continuous level measurement Radar transmitters
Overview Configuration Mounting on a nozzle is a 2-wire 25 GHz pulse radar level transmitter for continuous monitoring of solids and liquids in storage vessels including extreme levels of dust and high
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationIsolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones
Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationIncremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution
Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationCoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter
Operating Instruction OI/FCB100/FCH100-EN Rev. D CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter Measurement made easy Change from one to two columns Short product description Coriolis
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET TTF200 Field-mount temperature transmitter 2 TTF200 FIELD-MOUNT TEMPERATURE TRANSMITTER DS/TTF200-EN REV. B Measurement made easy Temperature transmitter
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationAdjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**
Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1
More informationAVP SERIES Aluminum Lighting for Hazardous and Severe Environments
AVP SERIES Aluminum Lighting for Hazardous and Severe Environments A V P Class I, Division 2, Groups A, B, C & D Zone 2, Group IIA, IIB, IIC UL 844 Hazardous Locations UL 1598A Marine Outside Type CUL
More informationGeneral Specifications
General Specifications YTA70 Temperature Transmitter The YTA70 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationLOGICA LED. Talk to the experts: Logica LED Emergency Luminaire
LOGICA LED Luminaire Logica IP65 Recessed Box - 12198 Luminaire Rapid Wall Fixing Bracket - 12199 Logica Metal Grid - 12194 Logica Right Diffuser - 12175 -- Logic Left Diffuser - 12176 -- Logica Diffuser
More informationIncremental encoders Blind hollow shaft or cone shaft pulses per revolution
Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80
More informationMT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D
MT MOTORI ELETTRICI Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D TABLE OF CONTENTS 1. Introduction 2. Scope of application 3. Installation
More informationFisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
More informationFor use in Flammable Gas and Dust Atmospheres
ISTRUCTIO MAUA (ATEX) BExCBG0505D Flameproof Combined / For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExCBG0505D is a second generation flameproof combined beacon / beacon which is
More informationRADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below
BLISSFLEX 1100 The characters of the order code have been described below BA25 4 BLISSFLEX 1100 C 2-wire loop-powered 4...20 ma Guided Radar (TDR) level meter: -50...+100 C and -1...16 barg / -58...212
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More information2-way pilot operated solenoid valves for water, hot water and steam
2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8658/GB NEW Also available with ATEX Explosion-proof electrical parts Technical specifications General description Applications
More informationOPTIWAVE 7300 C Supplementary instructions
OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationSYSTEMS AND PARTS EARTHING CONTROL: S604 & S804. Background. Product. Functioning SYSTEMS AND PARTS - EARTHING CONTROL
StuvEx NV (Belgium) EARTHING CONTROL: S604 & S804 Background Static electricity is a frequent source of ignition An electrostatic charge can be generated while handling conductive liquids or powders. This
More informationAccutech TC10. Wireless thermocouple temperature field unit
Accutech TC10 Wireless thermocouple temperature field unit 1 The Accutech TC10 wireless thermocouple temperature field unit provides temperature data using standard J, K, S and T-type thermocouples. Probes
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationTemposonics. Magnetostrictive Linear Position Sensors. TH SSI Data Sheet
Temposonics ostrictive Linear Position Sensors TH SSI ATEX / IECEx / CEC / NEC / EAC Ex certified / Japanese approval Continuous operation under harsh industrial conditions Flameproof / Explosionproof
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationProcedure for Constructing Housings for Passive Field Sampling
Page 1 of 5 SOP #: 1130 1.0 Purpose and Applicability Procedure for Constructing Housings for Passive Field Sampling This document outlines a procedure for preparing a weather-proof housing for the Wagner-Leith
More information