SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

Size: px
Start display at page:

Download "SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS"

Transcription

1 SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval received for Solenoid Type 17 (BCE Weather Proof). 4. Explanation about Difference in Indian ATEX marking & its Regulations. 5. Comparison of Ingress Protection (IP) Rating, NEMA Rating & Type Rating.

2 COIL CODE WITH SIZE COIL SIZE COIL CODE - Exd COIL CODE Ex ia I 14mm 37, 39, --- II 18mm 37, 39, III 14mm 37, 39, 87 66, 63, 64, 72, 73, 65CR IV 14mm 37, 39, 87 62, 71L, 67L III 13mm -- 71, 67

3 FLAMEPROOF / EXPLOSION PROOF SOLENOID WITH JUNCTIONAL BOX WITH / WITHOUT LED Ex d TYPE 37 & 39 APPROVALS Certification Body KLPL BIS CCOE DGMS 1. ATEX CESI, ITALY 2. UL* 3. INMETRO CEPEL, BRASIL 4. GOST-R CIS, THE NETHERLANDS 5. IEC Ex* 6. GOST-K CIS, THE NETHERLANDS (* - Applied for) Options : Class H (All Sizes) : Insulation FR (II & III) : Fully Rectified LC (II & III) : Latch MR(II & III) : Manual Reset LW (II & III) : Low Watt FPJB SOLENOID Size ( I / II / IIII / V) Cable Entry AL Enclo. SS Enclo. AL Enclo. SS Enclo. Without LED With LED 1/ 2 NPT CO 37LD 37LD-CO M20 X CO 39LD 39LD-CO

4 FLAMEPROOF / EXPLOSION PROOF SOLENOID WITH JUNCTIONAL BOX WITH / WITHOUT LED Ex d TYPE 37 & 39 NAME PLATE DETAILS for ATEX If requirement is T5 then marking shall be as following. II 2GD Ex d IIC T6 or T5 or T4 Gb Ex tb IIIC T80 C or T95 C or T130 C Db IP66 Tamb 40 C to +35 C or +50 C or +60 C

5 FLAMEPROOF / EXPLOSION PROOF SOLENOID WITH JUNCTIONAL BOX WITH / WITHOUT LED Ex d TYPE 37 & 39 NAME PLATE DETAILS for LABEL P218046/1 Coil Size I III II IV Max. Power Max. Ambient Temp. C T6 (80) T5 (95) T4 (130) Max. AC Voltage Max. DC Voltage

6 APPLICABILITY OF LED OPTION WRT POWER COIL TYPE 37 LD & 39 LD (applicable to Indian & Export both) LED will be provided to the wattages indicated in the table. This is applicable to all sizes. Voltages will be 6, 12, 24, 110, 230 AC / DC or DC. Power in Watt Ambient Temp. Range 2 W 25 C to 80 C 5 W 25 C to 65 C 8 W 25 C to 60 C 11 W 25 C to 60 C 15 W 25 C to 50 C 20 W 25 C to 40 C 30 W 25 C to 40 C

7 FLAMEPROOF / EXPLOSION PROOF SOLENOID WITH JUNCTIONAL BOX WITH / WITHOUT LED Ex d TYPE 37 & 39 NAME PLATE DETAILS INMETRO NAME PLATE DETAILS GOST

8 FLAMEPROOF /EXPLOSION PROOF SOLENOID WITH JUNCTION BOX WITH & WITHOUT LED TYPE : 87 Ex d APPROVALS Certification Body KLPL* IP 68 BIS* CCOE* DGMS* 1. ATEX DNV, NORWAY 2. UL * 3. INMETRO* CEPEL, BRASIL 4. GOST-R CIS, THE NETHERLANDS 5. IEC Ex DNV, NORWAY 6. GOST-K CIS, THE NETHERLANDS (* - Applied for) Options : Class H (All Sizes) : Insulation FR (II & III) : Fully Rectified LC (II & III) : Latch MR(II & III) : Manual Reset LW (II & III) : Low Watt BCE Approved for IP 68 from NABL Approved Indian Laboratory. Cert. No.: KLPL/BTG/13/07 51B R1 Cable Entry EXPLOSION PROOF SOLENOID WITH JUNCTION BOX AL Enclo. (W/out LED) Type-87 (Size-II/ III/ IV) AL Enclo. - With LED SS Enclo. - W/out LED SS Enclo. - With LED M25 X LD 87-CO 87LD-CO 1/ 2 NPT 87NS 87LD-NS 87NS-CO 87LD-NS-CO M20 X MS 87LD-MS 87MS-CO 87LD-MS-CO 3/4 NPT 87NL 87LD-NL 87NL-CO 87LD-NL-CO

9 T Class T Cable C T6 85 T5 100 T4 135 T3 150 Description Ex d Junction Box for Solenoid power up to 20W. Ex d Junction Box for Solenoid power for 30W. BOTTOM CABLE ENTRY Type 87 Without LED Bottom Cable Entry (Type 87) Bottom Cable Entry (Type 87) NAME PLATE DETAILS for ATEX DNV X Coil Size III Max. Power II 2GD Ex d IIC T6 ~ T3 Gb Ex t IIIC T80 ~ T155 Db IP67 60 C Tamb +100 C II 2GD Ex d IIC T4 ~ T3 Gb Ex t IIIC T80 ~ T155 Db IP67 60 C Tamb +70 C II IV T6 (80) Max. Ambient Temp. C T5 (95) T4 (130) T3 (155) Max. AC Voltage Max. DC Voltage If requirement is 8 Watt, Size III then marking will be as follows.

10 FLAMEPROOF / EXPLOSION PROOF SOLENOID WITH JUNCTIONAL BOX WITH / WITHOUT LED Ex d TYPE 87 NAME PLATE DETAILS GOST

11 APPLICABILITY OF LED OPTION WRT POWER COIL TYPE 87 LD LED will be provided to the wattages indicated in the table. This is applicable to all sizes. Voltages will be 6, 12, 24, 110, 230 AC / DC or DC. Power in Watt Ambient Temp. Range 2 W 25 C to 80 C 5 W 25 C to 65 C 8 W 25 C to 60 C 11 W 25 C to 60 C 15 W 25 C to 50 C 20 W 25 C to 40 C 30 W 25 C to 40 C

12 APPROVALS INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 62 & 66 Certification Body KLPL BIS IP 68 CCOE* DGMS* 1. ATEX BASEEFA, UK 2. INMETRO* CEPEL, BRASIL 3. GOST-R CIS, THE NETHERLANDS 4. IEC Ex BASEEFA, UK 5. GOST-K CIS, THE NETHERLANDS (* - Applied for) Entity Parameter Ui Ii 32VDC 230mA Pi 2.3W Ci 0 Li 0 Options : Class H (All Sizes) : Insulation BCE Approved for IP 68 from NABL Approved Indian Laboratory. Cert. No.: KLPL/BTG/13/07 51B R1 INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Type-62 (Size IV) - Code Type-66 (Size-III) - Code Cable Entry AL Enclo. SS Enclo. AL Enclo. SS Enclo. M25 X C C0 1/ 2 NPT 62NS 62NS-CO 66NS 66NS-CO M20 X MS 62MS-CO 66MS 66MS-CO 3/4 NPT 62NL 62NL-C0 66NL 66NL-CO

13 INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 62, Size IV, GA Drawing

14 INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 66, Size III GA Drawing

15 Voltage Operating Parameter INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 62 & 66, Size IV & III IS Coil with circuit (Size III) Coil Code : 66 IS Coil with circuit (Size IV) Coil Code : 62 Minimum Voltage 11 Volt 14 Volt Minimum Current 20 ma 25 ma Minimum Power 0.22 Watt 0.35 Watt Valve Type 9.4 VDC 9.5 VDC 10 VDC RESPONSE ON TIME 10.5 VDC 11 VDC Time in Sec. < 2.5 < < 1.7 < 1.5 < 1.3 < 1.2 < 1.0 < 0.9 < 0.8 < 0.7 < 0.5 2XXXX, 3XXXX, 5XXXX, 3XXX, VB (except 30308, 30334, 30138, etc.) 11.5 VDC 12 VDC 12.5 VDC 13 VDC RESPONSE OFF TIME : 10 ms to 20mS. MINIMUM OPERATING PARAMETER 13.5 VDC 14 VDC 14.5 VDC 30308, 30318, 30334, & any equivalent design type.

16 INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 62 & 66 NAME PLATE DETAILS ATEX & IECEX In Case of SS Enclosure In Case of AL Enclosure

17 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 67 & 67L APPROVALS Certification Body KLPL* BIS* CCOE* DGMS* 1. ATEX BASEEFA, UK 2. INMETRO* CEPEL, BRASIL 3. GOST-R CIS, THE NETHERLANDS 4. IEC Ex BASEEFA, UK 5. GOST-K CIS, THE NETHERLANDS (* - Applied for) Entity Parameter Ui 32VDC Ii 230mA Pi 2.3W Ci 0 Li 0 Options : Class H (All Sizes) : Insulation LOW POWER INTRINSICALLY SAFE SOLENOID Type-67 (Size-III) - Code Type-67L (Size-IV) - Code Cable Entry AL Enclo. SS Encl. AL Enclo. SS Encl. M25 X C0 67L 67L-C0 1/ 2 NPT 67NS 67NS-CO 67LNS 67LNS-CO M20 X MS 67MS-CO 67LMS 67LMS-CO 3/4 NPT 67NL 67NL-CO 67LNL 67LNL-CO

18 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 67, Size III GA Drawing

19 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 67L, Size IV GA Drawing

20 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE & 67 & 67L, Size III & IV MINIMUM OPERATING PARAMETER Valve Code Max. Pressure Operating Parameter Low Power IS (Size III) Coil Code : 67 Low Power IS (Size IV) Coil Code : 67L Minimum Voltage 10.5 V I3XXX & I5XXX 8 bar Minimum Current 18 ma Will inform you later on. Minimum Power W I3XXXEP & I5XXXEP 11 bar Minimum Voltage Minimum Current Minimum Power 14 V 25 ma W Will inform you later on. Response ON Time : 50 milli Sec Response OFF Time : 30 milli Sec

21 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 67 & 67L NAME PLATE DETAILS ATEX & IECEX In Case of SS Enclosure In Case of AL Enclosure

22 APPROVALS LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 71 & 71L Certification Body KLPL* BIS* IP 68 CCOE* DGMS* 1. ATEX BASEEFA, UK 2. INMETRO* CEPEL, BRASIL 3. GOST-R CIS, THE NETHERLANDS 4. IEC Ex BASEEFA, UK 5. GOST-K CIS, THE NETHERLANDS (* - Applied for) Entity Parameter Ui Ii 32VDC 230mA Pi 2.3W Ci 0 Li 0 Options : Class H (All Sizes) : Insulation BCE Approved for IP 68 from NABL Approved Indian Laboratory. Cert. No.: KLPL/BTG/13/07 51B R1 Cable Entry LOW POWER INTRINSICALLY SAFE SOLENOID Type-71 (Size-III) - Code AL Enclo. SS - Enclosure Type-71L (Size-IV) - Code AL Enclo. SS - Enclosure M25 X C0 71L 71L-C0 1/ 2 NPT 71NS 71NS-CO 71LNS 71LNS-CO M20 X MS 71MS-CO 71LMS 71LMS-CO 3/4 NPT 71NL 71NL-CO 71LNL 71LNL-CO New Color for BCE ( Azzure Blue )

23 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 71, Size III GA Drawing

24 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 71L, Size IV GA Drawing

25 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE & 71 & 71L, Size III & IV MINIMUM OPERATING PARAMETER Valve Code I3XXX & I5XXX I3XXXEP & I5XXXEP Max. Pressure 8 bar 11 bar Operating Parameter Minimum Voltage Minimum Current Minimum Power Minimum Voltage Minimum Current Minimum Power Low Power IS (Size III) Coil Code : V 18 ma W 14 V 25 ma W Low Power IS (Size IV) Coil Code : 71L Will inform you later on. Will inform you later on. Response ON Time : 50 milli Sec Response OFF Time : 30 milli Sec

26 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia TYPE 71 & 71L NAME PLATE DETAILS ATEX & IECEX In Case of SS Enclosure In Case of AL Enclosure

27 INTRINSICALLY SAFE SOLENOID WITH CIRCUIT Ex ia TYPE 63 & 64 APPROVALS KLPL BIS CCOE DGMS Entity Parameter Ui 32VDC 28VDC 24VDC Ii 80mA 120ma 170ma Pi 0.75W Ci 0 Li 0 Important Note: Please select Coil Type- 66 for ATEX, GOST-R, GOST-K, IN-METRO approval.

28 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia d TYPE 72 & 73 APPROVALS KLPL BIS CCOE DGMS Entity Parameter Ui 32VDC Ii 75mA Pi 0.75W Ci 0 Li 0 LOW POWER INTRINSICALLY SAFE SOLENOID WITH ENCLOSURE Exd AL Type 72 Code Type 73 Code Cable Entry AL Enclo. AL Enclo. 1/ 2 NPT (F) 72 M20 X 1.5 (F) 73 Important Note: Please select Coil Type-67 for,, ATEX, GOST-R, GOST-K, IN-METRO, IECEX approval.

29 LOW POWER INTRINSICALLY SAFE SOLENOID Ex ia & ia d TYPE 65CR APPROVALS KLPL BIS CCOE DGMS Coil Code 65CR Marking I M1, EEx ia IIC T6, IP67 ( 40 C Ta + 70 C) or II 1GD, EEx ia d IIC T6, IP67 ( 40 C Ta + 70 C) Options : Class H (All Sizes) : Insulation FR (II & III) : Fully Rectified MR(II & III) : Manual Reset LW (II & III) : Low Watt LOW POWER INTRINSICALLY SAFE SOLENOID WITH PLUG IN ENCLOSURE Cable Entry Pg9 Type 65CR

30 APPROVALS CCOE 1. ATEX DNV, NORWAY FLYING LEAD DUAL COIL Ex md TYPE 60 & 61 Options : Class H (All Sizes) : Insulation FLYING LEAD DUAL COIL Ex md With LED Without LED AL Enclosure SS - Enclosure CO CO-01

31 FLYING LEAD DUAL COIL Ex md TYPE 60 & 61 NAME PLATE DETAILS ATEX

32 SOLENOID TYPE WEATHER PROOF Recently we have received approval for Bottom Cable Entry Type Weather Proof. Solenoid is available with Protection Type. 3, 3R, 3S, 4, 4X, 6 & 6P. Voltages 24V, V, V, 50Hz / 60Hz/DC or 6, 12, 24, 110,220 or 256 VDC. Following Power. LW0.4, LW1, LW2, LW3.5, LW5, LW8, LW11, LW15, LW20 or LW30.

33 Comparison of Ingress Protection (IP), Type & NEMA Sr. No. Ingress Protection (IP) Rating Type rating NEMA Rating 1 IP IP 14 3R 3R 3 IP 54 3S 3S 4 IP IP 66 4X 4X 6 IP IP 67 6P 6P

34 Difference between Indian & ATEX Marking. Indian Marking ATEX Marking P218046/1 Recently we had few problem for Marking in regards with Indian & ATEX. Please note that if the requirement is of ATEX then we need to provide II 2 GD. In India there is no concept of GAS & DUST is applicable. So this concept is only applicable for ATEX. While in India the Marking is only Ex d IIIC Tx IP67. In India we have IP approval of IP 67 while in ATEX it is limited to IP 66 only.

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Fisher 646 Electro-Pneumatic Transducers

Fisher 646 Electro-Pneumatic Transducers Product Bulletin D101374X012 646 Transducers Fisher 646 Electro-Pneumatic Transducers Fisher 646 electro-pneumatic transducers, shown in figure 1, use a patented converter module that converts a 4 to 20

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes AI 23 / Issue W - 01/ IMPORTANT: This document should be read carefully before commencing installation Zones of Use of Box CAT II 2G for use in Zone

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Control CONNECTOR. (AI500 Rev H 14Nov17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA.

Control CONNECTOR. (AI500 Rev H 14Nov17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. Control CONNECTOR (AI500 Rev H 14Nov17) Hawke International UK Office, Oxford Street West, Ashton-under-Lyne, Lancashire. OL7 0NA. UK Sales: +44 (0) 161 830 6698 Technical: +44 (0) 161 830 6697 Fax: +44

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

VITO LT. Global Experience. Locally Applied. A dependable choice.

VITO LT. Global Experience. Locally Applied. A dependable choice. VITO LT A dependable choice. your accuracy requirements for tank inventory. Global Experience. Locally Applied. The VITO LT probe belongs to the VITO family for temperature and water bottom measurement.

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax: OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

For use in Flammable Gas and Dust Atmospheres

For use in Flammable Gas and Dust Atmospheres ISTRUCTIO MAUA (ATEX) BExCBG0505D Flameproof Combined / For use in Flammable Gas and Dust Atmospheres 1) Introduction The BExCBG0505D is a second generation flameproof combined beacon / beacon which is

More information

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation

More information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22

Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22 Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)

More information

TIY Programmable, Isolated Thermocouple Transmitter combines

TIY Programmable, Isolated Thermocouple Transmitter combines April 2016 Description Moore Industries unique digital/analog hybrid the combines smart digital technology with advanced analog operation to deliver superior reliability, accuracy and ease of use. Microprocessor-based,

More information

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet

ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet ST5484E Seismic Velocity 4-20 ma Transmitter Datasheet OVERVIEW The ST5484E is a self-contained seismic velocity transmitter that incorporates a piezoelectric accelerometer, signal integrator, RMS peak

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent stability.

More information

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp

Lighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant

More information

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

SOLENOIDS, COILS & ACCESSORIES Product Index

SOLENOIDS, COILS & ACCESSORIES Product Index SOLENOIDS, COILS & ACCESSORIES Product Index Description Series Page Coil identification Catalogue numbers of replacement coils SOLENOID OPERATORS Solenoid s, description and dimensions V1100-2/3 V1100-4..6

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 Table of contents Table of contents

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 13.0023X Issue No.: 0 Description: The Measuring Gauge of type series SMALL * / / / / / / / / / / * / * is an intrinsically safe supplied apparatus providing different electronic

More information

TGF2200 Micro Pulse Level Meter

TGF2200 Micro Pulse Level Meter Guided Radar with 2-wire system TGF2200 Micro Pulse Level Meter OUTLINE The TGF2200 series is a unique 2-wire continuous level-measuring instrument using TDR technology. The simple and compact design suitable

More information

ATEX Installation Drawings and Instructions

ATEX Installation Drawings and Instructions Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T**

Adjustable Terminal Clamp Insulation. Fixed Terminal Clamp See Terminal Wiring Note. Body. Maximum Power Dissipation (Watts) T** T*** -60 C +55 C T** Assembly Instructions for: PL ** Series Junction Boxes IMPORTANT: This document should be read carefully before commencing installation Zones of Use for Box - as defined in IEC/EN 00-0 and IEC/EN 00--1

More information

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products

AT200 Magnetostrictive Level Transmitter. External mounted magnetostrictive level transmitter K-TEK Products Data sheet DS/-EN Rev. T Magnetostrictive Level Transmitter External mounted magnetostrictive level transmitter K-TEK Products Features SIL2 Certified IEC 61508* Designed to mount externally to K-TEK KM26

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Sarasota CM200 Sarasota HME900 Density Converter Electronics Sarasota CM00 Sarasota HME00 Density Converter Electronics Users of Sarasota density meters or specific gravity analyzers are offered the choice of a HART compatible, field mounted density converter, or

More information

Flow rate Indicator / Totalizer

Flow rate Indicator / Totalizer Datasheet ER100(M) Robust explosion proof indicator Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate

More information

User's Manual Model SE14 Magnetic Flow Converter

User's Manual Model SE14 Magnetic Flow Converter User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the

More information

Process display RIA 261

Process display RIA 261 Technical Information TI 083R/24/ae Process display RIA 261 Digital loop powered field display for 4 to 20 ma current loops Features and Benefits Loop powered display, no additional power supply cable

More information

Operating Manual. isolate501

Operating Manual. isolate501 Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1

More information

ü ( Explosion Protection

ü   ( Explosion Protection Explosion Protection ü www.nassmagnet.com ( +49 11 6746-0 Explosion Protection SOLENOID COILS FOR USE IN POTENTIALLY EXPLOSIVE ENVIRONMENTS nass magnet offers components of the series System 8 and System

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

FICHA TÉCNICA DE PRODUTO

FICHA TÉCNICA DE PRODUTO FICHA TÉCNICA DE PRODUTO PRODUCT DATASHEET HI Automação e Instrumentação, Lda. Rua Dr. Oliveira Salazar, nº 88 4780-453 Santo Tirso PORTUGAL Web: www.hmi.pt Tel. +351 252 809 124 Fax. +351 252 859 298

More information

J: Emergency lighting (optional) L: pole type X: ceiling type

J: Emergency lighting (optional) L: pole type X: ceiling type Lighting Technology Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone and Zone Zone and Zone

More information

All TXI7850 products are ROHS compliant.

All TXI7850 products are ROHS compliant. Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all

More information

General Specifications

General Specifications General Specifications GS 01F06F01-01EN Model DY Vortex Flowmeter Model DYA Vortex Flow Converter FOUNDATION Fieldbus Communication Type General FOUNDATION Fieldbus is the digital communication line for

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model

AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model No. SS2-GTX00G-0600 AT9000 Advanced Transmitter Gauge Pressure Transmitters In-line model OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance

More information

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Level Radar TLR3000 MICROWAVE level meter GENERAL The TLR3000 is a non-contact type continuous level meter using microwaves. It detects a level by measuring a reciprocating time of a microwave

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

Emerson (Appleton Group ATX)

Emerson (Appleton Group ATX) These assemblies are available in AC-powered and DC-powered versions. They have space to land 48 or 96 CHARM I/O depending on the model chosen. The field I/O can be specified as either IS or NON-IS I/O.

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE

PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

BExBG05 Xenon Beacon The flameproof BExBG05 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications.

BExBG05 Xenon Beacon The flameproof BExBG05 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. E2S Datasheet 1.4.3 v10a BExBG05 Xenon Beacon The flameproof BExBG05 Xenon beacons are suitable for Zone 1, 2, 21 & 22 applications. The BExBG05 5 Joule beacons are ideal for general signalling duties

More information