Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
|
|
- Godfrey Miller
- 6 years ago
- Views:
Transcription
1 > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up to 8 channels can be used as frequency/counter inputs; with rotation direction recognition > Line fault monitoring > LED display for signal and errors for each channel > Additional control input for "Plant STOP" (in accordance with IEC up to SIL2) > Energized module can be replaced in hazardous areas (hot swap) > Function-compatible replacement for IS1 I/O modules: 9470/25 and 9471/15 series 17616E00 The 24 V digital input output module can connect up to 16 non-intrinsically safe digital signals to the IS1+ remote I/O system. All channels can be configured as inputs for NAMUR proximity switches (EN ), 3-wire PNP proximity switches (with a 24 V supply) as well as for passive contacts and for solenoid valves (24 V / 0.5 A) (in pairs with adjustable parameters). The external power supply for 3-wire proximity switches and solenoid valves comes from a separate terminal on the front side of the module. Up to 8 inputs can be used as frequency inputs or as counters up to 20 khz. In the "rotation direction recognition" and "forward/backward counter" operating modes, it is up to 4 inputs. An additional "Plant STOP" control input on the front side of the module is used to safely switch off all outputs. All inputs and outputs are monitored for short circuiting and line breakage. ATEX / IECEx Zone For use in x x WebCode 9472A Remote I/O /1
2 Selection Table Version Description Installation Order number Weight kg Digital input 16 channels with adjustable parameters Zone 2, 22 and 9472/ output module 24 V, for NAMUR proximity switches / contacts, safe area 3-wire PNP proximity switches with 24 V power supply, solenoid valves (24 V / 0.5 A), with channel status LEDs and "Plant STOP" Note Order 2 terminals separately - see Accessories This module is not supported by the Ethernet CPU 9441! Explosion Protection Global (IECEx) Gas and dust Europe (ATEX) Gas and dust Certifications and certificates Certificates Ship approval Further parameters Installation Further information Ex ec [Ex ia Ga] IIC T4 Gc [Ex ia IIIC Da] E II 3 (1) G Ex ec [Ex ia Ga] IIC T4 Gc E II (1) D [Ex ia IIIC Da] IECEx, ATEX In progress Zone 2, 22 and safe area see respective certifcate and operating instructions Electrical data Ex n inputs / outputs Number of channels 16 (in pairs with adjustable parameters as input or output) Ex n inputs Max. number of channels 16 Min. ON input signal 2.1 ma Max. OFF input signal 1.2 ma Switching threshold 1.65 ma Supply voltage 8.0 V ± 5% Internal resistance 1 k Ω Signal IEC (NAMUR) or 3-wire PNP proximity switches with and without 10 kω / 47 kω resistance connected in parallel Frequency input Max. number of channels 8 Max. switching frequency NAMUR input: 20 khz (at frequencies > 1 khz the maximum conductor length is reduced, e.g. at 5 khz to approx. 75 m) 3-wire PNP proximity switches: ( 500 Hz Min. pulse width NAMUR input: 25 μs 3-wire PNP proximity switches: 1 ms Measuring range 1 Hz... 1 khz 1 Hz khz Resolution 0.05 Hz 1 Hz Accuracy 0.02% 0.02% Counter Max. number of channels 8 Counter range Rotation direction recognition, forward/backward counter Max. number of channels 4 (each with two inputs switched in parallel) Function Up/down counter; frequency with direction Resolution 16 bit / 32 bit /2 Remote I/O
3 Electrical data Ex n inputs / outputs Ex n outputs Max. number of channels 16 Output voltage U H -0.5 V Output current 5 ma A per channel (electrically limited) Total current of the outputs Depends on the ambient temperature: ( 4 A max. 75 C ( 8 A max. 65 C X0 external supply Supply voltage U H V DC Max. power 8 A (depends on the total current of the outputs) consumption I H Signal transmission Max. delay from < 1 ms signal / internal bus Max. delay from Filter without small medium large frequency input / internal bus Frequency 0.1 Hz ( f < 1 Hz 1/f + 1 ms 2/f 3/f 6/f 1 Hz ( f < 10 Hz 1/f + 1 ms 4/f 9/f 18/f 10 Hz ( f < 100 Hz 1/f + 1 ms 8/f 27/f 54/f 100 Hz ( f < 1 khz 1/f + 1 ms 16/f 81/f 162/f 1 khz ( f < 1,960 Hz 1.5 ms 32/f 243/f 486/f 1,960 Hz ( f < 10 khz 1.5 ms 16.5 ms 124 ms 248 ms 10 khz ( f < 20 khz 1.5 ms 33 ms 372 ms 744 ms f ) 20 khz 1.5 ms 66 ms 372 ms 744 ms Note: for 3-wire PNP proximity switches f < 1 khz X0 "Plant STOP" control input Function "Plant STOP" to switch off all outputs Suitability Switch off at SIL 2 (IEC 61508) Control input X0 3, 4 "Normal operation" ("Plant STOP" deactiviated) Terminals bridged "OFF" ("Plant STOP" activated) Interrupted Galvanic separation Test voltages acc. to standard EN Between ) 1800 V AC auxiliary power / system components Between I/O channels / ) 1800 V AC system components Between I/O channels / ) 1800 V AC ground (PA) Electromagnetic compatibility Tested to the following standards and regulations: EN (2006) IEC , NAMUR NE 21 Electrical connection Power supply BusRail Types 9494 Ex n field signals 2 plug-in, black terminals, 24-pin, 1.5 mm 2, push-in design with lock (must be ordered separately) External supply Plug-in, black terminals, 4-pin, 1.5 mm 2, screw terminal design with lock (included) and "Plant STOP" Auxiliary power Version Intrinsically safe Ex ia via BusRail Behaviour during All outputs "Off" undervoltage Max. current consumption 90 ma Max. power consumption < 2.2 W Max. power dissipation < 4.7 W Remote I/O /3
4 Device-specific data Settings Module Diagnostics message Signal Signal type Pulse extension / frequency filter Inverting input/output Line fault monitoring Behaviour in case of error Operating mode counter/frequency Counter control Counting event ON / OFF NAMUR proximity switch / contact; 3-wire PNP proximity switch; output 0 s / off; 0.6 s / small; 1.2 s / medium; 2.4 s / large (setting is made for channel pairs) normal / inverted (setting is made for channel pairs) ON / OFF Replacement value '0'; replacement value '1'; hold (initial value 0); hold (initial value 1) Counter 16 bit; Hz; 1 Hz... 3 khz; 1 Hz khz; 1 Hz khz with direction; Up/Down 16 bit counter; Up/Down 32 bit counter (setting is made for channel pairs) Run, Stop, Reset Positive slope; negative slope (setting is made for channel pairs) Ambient conditions Ambient temperature C (observe operating instructions) Storage temperature range C Maximum relative humidity 95% (without condensation) Maximum operating height < 2,000 m Semi-sinusoidal shock 15 g (3 shocks per axis and direction) (IEC EN ) Sinusoidal vibration (IEC EN ) 1 g in the frequency range Hz 2 g in the frequency range Hz Mechanical data Degree of protection (IEC 60529) IP30 Module enclosure Polyamide 6GF Fire resistance (UL-94) V2 Pollutant class corresponds to G3 Dimensions L = mm, W = 98 mm, H = 64 mm Indication LED indication Module requires maintenance "M/S" LED, blue Operating state "RUN" LED, green Group error "ERR" LED, red Channel error LED, red for each channel Channel status LED, yellow for each channel 24 V external supply "24 V" LED, green "Plant STOP" "24 V" LED, yellow Function indication Retrievable parameters Manufacturer, type, hardware revision, software revision, serial number Error indication Module status and alarms Signal errors for each channel Signal status bit Open circuit Primary / redundant internal bus error No response from IOM Configuration does not correspond to the module Hardware error Excess temperature Slot error Module requires maintenance "1" = signal interfered; "0" = signal valid NAMUR input: I < 100 μa 3-wire PNP proximity switch: U IN < 1.6 V Output: I < 30 μa in ON state R > 8 kω in OFF state Short circuit NAMUR input: 3-wire PNP proximity switch: R < 100 Ω U IN < 1.6 V Output: I < 700 ma in ON state R > 40 kω in OFF state Mounting / Installation Installation position Horizontal or vertical (observe operating instructions) Mounting type On 35 mm DIN rail NS 35/15 (DIN EN 60715) /4 Remote I/O
5 Accessories and Spare Parts Designation Figure Description Art. no. Plug-in terminal 1.5 mm 2 with lock, 24-pole, spring clamp connection, black, for connecting the field signals to I/O modules, for non-intrinsically safe field circuits Caution: only for 9471/35 and 9472/35 I/O modules Labelling: Resistor error message suppression Labelling strips 17744E E E mm 2 with lock, 24-pole, spring clamp connection, black, for connecting the field signals to I/O modules, for non-intrinsically safe field circuits Caution: only for 9471/35 and 9472/35 I/O modules Labelling: The resistors are used to suppress error messages for unused I/O channels Resistance value: 5K6 / 0.5 W Suitable for: AIM 9468; DIOM 9470; DIOM 9471; DIOM 9472; DOM 9475 For intrinsically safe circuits (simple apparatus according to EN ) "FB Addr... Mod No..." for pluggable terminal, sheet with 26 strips DIN sheet 05869E00 For label plate on I/O modules; 6 labels on each sheet; print-out using IS Wizard; packaging unit = 20 sheets Partition 09900E00 For mounting between intrinsically safe and non-intrinsically safe connections of the I/O modules, in order to adhere to the required 50 mm distance Warning sign 15196E00 "Clean modules only with a damp cloth." E00 Dimensional Drawings (All dimensions in mm [inches]) Subject to alterations 68 [2,68] 136 [5, 35] 128,5 [5,06] 139,50 [5, 49] 64 [2,52] 70 [2,76] 98 [3,86] 96,5 [3,8] 17625E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. Remote I/O /5
Digital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationAssembly. Front view. HiC2441. SL2 1b. Termination Board
SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up
More informationEngineering Guideline. pac-carriers Type for Yokogawa Centum VP
Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationEP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442
October 2017 RSTI-EP Slice I/O Specialty Modules EP-5111, EP-5112, EP-5212, EP-5261, EP-5311, EP-5422, EP-5442 Module Status LED Channel Status LED GE provides several RSTi-EP specialty modules, which
More informationTechnical Information Barrier RB223
TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive) Application-specific outputs Line fault transparency
More informationAssembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II
Switch Amplifier Features Assembly -channel isolated barrier 5 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC 6508/EC
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationSignal conditioner - MACX MCR-UI-UI-NC
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid
More informationAssembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC
More informationFieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex
Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationDIN Rail Devices. CEAG Sicherheitstechnik GmbH 194
DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped
More informationPulse Scaler for DIN Rail Attachment
Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary
More informationDeltaV SIS Logic Solver
DeltaV SIS Process Safety System Product Data Sheet September 2017 DeltaV SIS Logic Solver World s first smart SIS Logic Solver Integrated, yet separate from the control system Easy compliance with IEC
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50
Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationRail mounted Temperature Transmitter TH102/TH102-Ex
Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationMotor Protection Circuit Breaker Series 8146/5-V27
www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >
More informationSITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationSignal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More informationControl Unit Series 8208
> Installation of various components such as Snap action switch Potentiometer Relay Time relay Diodes Fuses Resistors www.stahl.de 01776E00 Components of various functions such as diodes, resistors, fuses
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More informationRotary Measuring Technology
Our ATEX encoders now also carry approval for Dust Flameproof-enclosure type of construction with approval for Zone 1 and 21 ExII2GEExdIICT6 and ExII2DIP6xT85 C Shaft ø 12 mm One type for every situation:
More informationRailbus isolator. Railbus isolator 8922-RB-IS
Railbus isolator Railbus isolator 8922-RB-IS provides galvanic isolation between Railbus sections prevents fault-voltage invasions protects IS field wiring modules See also System Specification Dimensions
More informationPRetrans Table of contents
HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationSINEAX TV809, 1 channel Programmable Isolating Amplifier
For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and
More informationMACX MCR-EX-SL-RPSSI-I-UP(-SP)
Supply and input signal conditioner, Ex-i, with wide range supply Data sheet 103561_en_00 PHOENIX CONTACT 2014-08-19 1 Description The MACX MCR-EX-SL-RPSSI-I-UP(-SP) repeater power supply and input signal
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationOperating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationPreset counters, electronic
The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their
More informationitemp HART DIN rail TMT112
Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application
More informationA6500-UM Universal Measurement Card
Specifications Sheet A6500-UM Universal Measurement Card The A6500-UM Universal Measurement Card is a component of the CSI 6500 ATG machinery protection system. The card is equipped with 2 sensor input
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationType CP-S, CP-C & CP-A Switch mode
Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationLevel Limit Switch nivotester FTL 325 P
Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationType Nominal voltage (V) Code HSV V
Speed control Speed control relay - mm Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - -wire PNP or NPN, Namur, voltage 0-0V or volt-free contact type Works
More informationCP-T range Product group picture
Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationPHOENIX CONTACT - 09/2009
Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits
More informationTechnical Information RMA42
TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values
More informationRudder or propeller angular position transmitter KINAX WT720
Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationOperating Instructions
Operating Instructions FLUDEX-EOC system A. Friedr. Flender AG 46393 Bocholt Tel. 02871/92-0 Telefax 02871/92-2596 www.flender.com Contents 1. Application 3 2. Operation 3 3. Fitting 4 3.1 Fitting transmitter
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationCP-T range Benefits and advantages
Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers
More informationSISNet Repeater. SISNet Repeater. Introduction. DeltaV SIS Product Data Sheet. Dedicated safety communications. Full communications redundancy
April 2011 Page 1 DeltaV SIS communication is extended beyond local logic solvers with s Dedicated safety communications Full communications redundancy Flexibility to meets project needs Consistent update
More informationBtdin RCD Add-on modules 63A for MCBs 1,5 modules per pole
Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics... 4 6. Compliance - Approvals... 6 7. Curves... 7 8. Auxiliares and
More information