Two-channel safety barriers Series 9002

Size: px
Start display at page:

Download "Two-channel safety barriers Series 9002"

Transcription

1 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation thanks to simultaneous snap-on mounting on rails and connection to PE and earth > Reduced stock-keeping thanks to a uniform back-up fuse Series E00 The R. STAHL INTRINSPAK safety s of Series 00 can be used for various tasks in the field of automation. The wide product range and scope of different combinations offer you a large field of applications. The safety s allow the intrinsically safe operation of HART transmitters, proximity sensors, potential-free contacts, temperature sensors, DMS, solenoid valves, indicators and others. Due to the compact width, space-saving and flexible installation in the switch cabinet is possible. Thanks to DIN-rail mounting and simultaneous connection of the equipotential bonding, the installation can be performed very easily. ATEX / IECEX NEC 5 NEC 6 NEC 0 Class I Class I Class II Class III Zone 0 0 Zone 0 0 Division Ex i interface x x x x x x Ex i interface Ex i interface x x x x x x Installation in x x Installation in x x Installation in x x x WebCode AK00 III en 00A Safety s /

2 Two-channel safety s Series 00 Explosion Protection Global (IECEx) Gas and dust IECEx PTB X Ex na [ia Ga] T4 Gc [Ex ia Da] I Europe (ATEX) Gas and dust PTB 0 ATEX 053 X E II 3 () G Ex na [ia Ga] / T4 Gc E II () D [Ex ia Da] I Certificates Certificates Further parameters Installation Further information Technical Data Electrical data Transmission characteristic Leakage current at Temperature influence Transmission frequency In case of resistive current limiting I m ( ma I m ) ma In case of electronic current limiting IECEx, ATEX, Brasil (INMETRO), Canada (CSA), Kazakhstan (TR), Korea (KCs), Russia (TR), Serbia (SRPS), Ukraine (TR), USA (FM, UL), Belarus (TR) in Zone, Division and in safe area see respective certificate and operating instructions ( ma (unless specified otherwise) ( 0.5 % / 0 K ( khz ( 00 khz ( 0 khz Ambient conditions Ambient temperature C Storage temperature C Maximum relative 5 % on average, no condensation humidity Mechanical data Degree of protection according to IEC 605 Terminal support IP0 Enclosure IP40 Enclosure material polyamide 6GF Connection type 4 connection terminals (cage terminals), each maximum.5 mm finely stranded / solid wire PA-terminals, each maximum 4 mm finely stranded / solid Weight approx 0.5 kg / Safety s AK00 III en

3 Two-channel safety s, potential: + / + Series 00/ Series 00/ Two-channel safety s, potential: + / + + U e + Ue Connection to regulated power supply Installation permitted in Division and Zone + Ue + Ue Channel R min R max I max Safety data Order number E0 U o I o P o V Ω Ω ma V ma mw mh mf mh mf *) max. leakage current I leak ( 0 ma Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety / / *) 00/ / / / / U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity AK00 III en Safety s /3

4 Two-channel safety s, potential: + / + Series 00/ Load cell (DMS) 3 Ω or 700 Ω 6 conductors + 6 V, field circuit unearthed +6 V 00/ / / Operating data Operating voltage ( + 6 V Voltage for load cell and U L (at = + 6 V) electric line Current for load cell I L (at = + 6 V) Number of the load cells connected in parallel Safety data Maximum voltage U o =. V I o = 85 ma external L o 0. mh external capacity C o 0.3 μf Maximum power P o =.4 W Application note 3 Ω 700 Ω U L (V) I ma (V) U L (V) I ma (V) mh.4 μf For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 55 ma, the maximum power to P o =.3 W. 3-wire NPN inputs (negative switching) of proximity switches, photocells and encoders NPN Supply / R L +4 V DC 0 V 063E0 /PA Discrete -wire output for solenoid valves, LEDs and signalling devices 0660E0 +4VDC 00/ VDC 06606E0 /4 Safety s AK00 III en

5 Two-channel safety s, potential: + / + Series 00/ Two-channel safety s, potential: + / + + U e + Ue Application for 3-wire NPN, sensors with voltage output Low nominal current Installation permitted in Division and Zone + Ue R L + Ue Channel R min R max I max Safety data Order number U o I o P o V Ω Ω ma V ma mw mh mf mh mf / Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety 0583E0 U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity 3-wire NPN inputs (negative switching) of proximity switches, photocells and encoders NPN Supply / R L +4 V DC 0 V /PA 0657E0 Application note With this all loop voltages must be checked to ensure correct function AK00 III en Safety s /5

6 Two-channel safety s, potential: + / + Series 00/ Two-channel safety s, potential: + / + + U e + Ue Application for 4/0 ma transmitter with -5 V input in the wiper Incl. precision resistance of Ω Installation permitted in Division and Zone + Ue + Ue 0584E0 Channel R min R max I max Safety data Order number U o I o P o + V Ω Ω ma V ma mw mh mf mh mf / Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity -wire, 4/0 ma transmitters - standard and HART ma +4VDC 00/ V V Input 33E0 Application note This safety is used if the automation system only accepts signals from to 5 V. This contains a Ω resistor to convert the signal... 5 V. /6 Safety s AK00 III en

7 Two-channel safety s, potential: - / - Series 00/00 Series 00/00 Two-channel safety s, potential: - / - -Ue -Ue Connection to regulated power supply Installation permitted in Division and Zone -Ue -Ue Channel R min R max I max Safety data Order number E0 U o I o P o V Ω Ω ma V ma mw mh mf mh mf Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety 00/ / / U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity Vibration sensor Sensor Transducer 00/ V DC max. Input Operating data Operating voltage = - 4V Series resistance of the R = 358 Ω safety Safety data Maximum voltage U o = 6 V I o = 38 ma external L o 0.8 mh external capacity C o μf Maximum power P o = 8 mw Application note AK00 III en 5. mh 0.67 μf Application of the for Bentley Nevada and Metrix position transducer. This has negative potential; for a positive potential, use the 00/ E0 Safety s /7

8 Two-channel safety s, potential: + / - Series 00/0 Series 00/0 Two-channel safety s, potential: + / - Application for load cells Channel for positive and negative potential in one module Installation permitted in Division and Zone -Ue -Ue 058E0 Channel R min R max I max Safety data Order number U o I o P o + + V Ω Ω ma V ma mw mh mf mh mf / / Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity /8 Safety s AK00 III en

9 Two-channel safety s, potential: + / - Series 00/0 Load cell (DMS) 3 Ω or 700 Ω 6 conductors +/- 7.5 V (5 V), field circuit unearthed 00/ / / ,5 V -7,5 V Operating data Operating voltage ( +/- 7.5 V (5 V) Voltage for load cell and U L (at ( +/- 7.5 V) electric line Current for load cell I L (at ( +/- 7.5 V) Number of the load cells 3 Ω 700 Ω connected in parallel U L (V) I ma (V) U L (V) I ma (V) Safety data Maximum voltage U o = 8.7 V I o = 330 ma external L o 0.8 mh.45 mh external capacity C o 0.7 μf.64 μf Maximum power P o =.45 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 30 ma, the maximum power to P o =.36 W. 06E AK00 III en Safety s /

10 Two-channel safety s, potential: ~ / ~ Series 00/ Series 00/ Two-channel safety s, potential: ~ / ~ +/-Ue +/-Ue +/-Ue +/-Ue Connection of a resistance teletransmitter is possible High precision resistance of each channel, 0 Ω ±0. Low temperature influence of < ppm/k Connection to regulated power supply Installation permitted in Division and Zone 05835E0 Channel R min R max I max Safety data Order number U o I o P o + V Ω Ω ma V ma mw mh mf mh mf *) max. leakage current I leak ( 0 ma / *) Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity /0 Safety s AK00 III en

11 Two-channel safety s, potential: ~ / ~ Series 00/ Pt00, -wire circuit, field circuit unearthed RTD Input T 00/ Operating data Operating voltage (.4 V 05E0 Series resistance of the safety Measuring range R = x (0 Ω +/- 0. Ω) ( 400 C (I N ( 5 ma) ( 8 C (I N ( 3 ma) Safety data Maximum voltage U o = 3. V I o = 300 ma external L o 0. mh.8 mh external capacity C o 00 μf Pt00, 3-wire circuit, field circuit unearthed 000 μf RTD Input T 00/ / Supply Voltage Operating data Operating voltage Series resistance of the safety Measuring range Safety data Maximum voltage (.4 V R = x (0 Ω +/- 0. Ω) ( 400 C (I N ( 5 ma) ( 8 C (I N ( 3 ma) U o = 3. V I o = 4 ma external L o 0. mh 0.5 mh external capacity C o 00 μf 000 μf 060E AK00 III en Safety s /

12 Two-channel safety s, potential: ~ / ~ Series 00/ Two-channel safety s, potential: ~ / ~ Connection to regulated power supply Installation permitted in Division and Zone +/-Ue +/-Ue +/-Ue +/-Ue 05845E0 Channel R min R max I max Safety data Order number U o I o P o V Ω Ω ma V ma mw mh mf mh mf / / / Nominal voltage I max Maximum output current P o Maximum power R min R max Minimum resistance of the safety Maximum resistance of the safety U o Maximum voltage L o max. permissible external I o C o max. permissible external capacity with RS 3 RS-3 Tx/Rx Tx/Rx Intrinsically Safe Field Device GND 00/ GND Interface Module 0664E0 / Safety s AK00 III en

13 Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: E0 Function: Channel current supply Channel evaluation No safety-relevant output current I o for channel Nominal current limited to 40 ma at Ω load Connection to unregulated power supply on to channel Installation permitted in Division and Zone Channel R min R max I max ãu Safety data Order number U o I o P o + V Ω Ω ma V V ma mw mh mf mh mf *) only for channel : leakage current at 4 V / 35 V I leak ( ma / 0 ma / *) Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible external U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power AK00 III en Safety s /3

14 Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Analog output (current source) for I/P converter etc., field circuit unearthed ma 00/ V DC 053E0 Operating data Operating voltage Operating current Maximum voltage drop at the safety Safety data Maximum voltage = V I N = 0... ma ΔU max ( 8. V U o = 5. V I o = ma external L o.5 mh external capacity C o 0.04 μf Maximum power P o = 763 mw 7.35 mh 0.8 μf Analog output (current source) for I/P converter etc., field circuit unearthed 00/ V DC Operating data Operating voltage Open-circuit output voltage (terminal 3 4, I n = 0) U L) Operating current Safety data Maximum voltage = V I N = U L / 43 Ω + R L U o = 5. V I o = ma ( 4 V V external L o.5 mh > 4 V V 7.35 mh external capacity C o 0.04 μf 0.8 μf Maximum power Application note P o = 760 mw 06604E0 This safety is used if the automation system activates the analog output signal in the return (negative) line. The field device and automation system are not earthed and unregulated power supply can be used. /4 Safety s AK00 III en

15 Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: E0 Function: Channel current supply Channel evaluation Connection to regulated power supply Installation permitted in Division and Zone Channel R min R max I max ãu Safety data Order number U o I o P o V Ω Ω ma V V ma mw mh mf mh mf *) only for channel : max. leakage current I leak ( 0 ma / *) 00/ / Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible external U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power AK00 III en Safety s /5

16 Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Load cell (DMS) 3 Ω or 700 Ω 6 conductors + 6 V, field circuit unearthed +6 V 00/ / / Operating data Operating voltage ( + 6 V Voltage for load cell and electric U L (at = + 6 V) line Current for load cell I L (at = + 6 V) Number of the load cells connected in parallel Safety data Maximum voltage U o =. V I o = 85 ma external L o 0. mh.8 mh external capacity C o 0.3 μf.4 μf Maximum power P o =.4 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 55 ma, the maximum power to P o =.3 W. Discrete -wire output for solenoid valves, LEDs and signalling devices 3 Ω 700 Ω U L (V) I ma (V) U L (V) I ma (V) 063E0 00/ VDC 06605E0 Application note This is suitable for use with regulated power supplies and earthed return circuits. The nominal voltage is 4 V. -wire 4/0 ma I/P converters and control valves - standard and HART, 4/0 ma indicators ma 00/ VDC Application note 334E0 This safety is used if the automation system activates the analog output signal in the return (negative) line. The field device and automation system are not earthed and a regulated power supply must be used. At an operating current of 0... ma, the maximum voltage drop across the will be 8.4 V. /6 Safety s AK00 III en

17 Two-channel safety s, safety potential: + / evaluation potential: + Series 00/3 Two-channel safety s, safety potential: + / evaluation potential: E0 Function: Channel current supply Channel evaluation No safety-relevant output current I o for channel Connection to unregulated power supply on to channel Nominal current limited to 35 ma Installation permitted in Division and Zone Channel R min R max I max ãu Safety data Order number U o I o P o + V Ω Ω ma V V ma mw mh mf mh mf *) only for channel : leakage current < 6 V / > 6 V I leak ( ma / 35 ma / *) Nominal voltage ãu Additional voltage drop across the safety R min R max Minimum resistance of the safety Maximum resistance of the safety L o max. permissible externa l U o Maximum voltage C o max. permissible external capacity I o I max Maximum output current P o Maximum power 3-wire PNP inputs (positive switching) of proximity switches, photocells and encoders PNP Supply / V DC /PA R L 0 V 0655E AK00 III en Safety s /7

18 Two-channel safety s, evaluation potential: + / evaluation potential: + Series 00/33 Series 00/33 Two-channel safety s, evaluation potential: + / evaluation potential: + Evaluation for direct current signals with max. output current I o Suitable for potential-free contacts and floating 4/0 ma signals Positive potential of both channels Installation permitted in Division and Zone 058E0 Channel I max ãu Safety data Order number U o I o + V ma V V ma mh mf mh mf *).5 V to 0 ma *) 3.5 *) / Nominal voltage U o Maximum voltage C o max. permissible external capacity I max Maximum output current I o ãu Additional voltage drop across the safety L o max. permissible external Combination of potential-free contacts 00/ V DC 00/ V 468E00 /8 Safety s AK00 III en

19 Two-channel safety s, evaluation potential: + / evaluation potential: - Series 00/34 Series 00/34 Two-channel safety s, evaluation potential: + / evaluation potential: - -Ue R L -Ue 0588E0 Evaluation for direct current signals with max. output current I o Application for passive signals of 4/0 ma (transmitter with 4 conductors or more) with insulated analog input on the control system Channel for positive and negative potential in one module Installation permitted in Division and Zone Channel I max ãu Safety data Order number U o I o + V ma V V ma mh mf mh mf *).5 V to 0 ma *) 3.5 *) / Nominal voltage U o Maximum voltage C o max. permissible external capacity I max Maximum output current I o ãu Additional voltage drop across the safety L o max. permissible external Transmitter (4-wire) ma 00/ Operating data Operating current Load Maximum voltage drop at the safety Safety data Maximum voltage external AK00 III en I N = 0... ma R L (7 Ω Δ U max ( 3.5 V U o = 8 V I o = 0 ma external capacity C o μf Maximum power Application note The is determined depending on the maximum current of the transmitter P o = 0 mw μf A potential-free input is required for the circuit. If the input is earthed, (R L to /PA), the safety 00/ can be used. 05E0 Safety s /

20 Two-channel safety s, star / star Series 00/77 Series 00/77 Two-channel safety s, star / star /-Ue /-Ue Connection to regulated power supply Suitable for voltage signals Installation permitted in Division and Zone AC version /-Ue /-Ue 05836E0 Channel R min R max Safety data Order number U o I o P o V Ω Ω V ma mw mh mf mh mf *) Ambient temperature C / / / / / *) 00/ *) 00/ Nominal voltage U o Maximum voltage L o max. permissible external R min R max Minimum resistance of the safety Maximum resistance of the safety I o C o max. permissible external capacity P o Maximum power /0 Safety s AK00 III en

21 Two-channel safety s, star / star Series 00/77 Load cell (DMS) 3 Ω or 700 Ω 6 conductors +/- 7.5 V (5 V), field circuit unearthed 00/ / / ,5 V -7,5 V Operating data Operating voltage ( +/- 7.5 V (5 V) Voltage for load cell and U L (at ( +/- 7.5 V) electric line Current for load cell I L (at ( +/- 7.5 V) Number of the load cells 3 Ω 700 Ω connected in parallel U L (V) I ma (V) U L (V) I ma (V) Safety data Maximum voltage U o = 8.7 V I o = 330 ma external L o 0.8 mh.45 mh external capacity C o 0.7 μf.64 μf Maximum power P o =.4 W Application note For 4-wire circuits (without sense) the respective safety might be unnecessary. The operating data remains unchanged. The safety-relevant maximum current is reduced to I o = 30 ma, the maximum power to P o =.36 W. Thermocouples Voltage Input 06E0 00/ Operating data Maximum series resistance R max = x 8. Ω of the safety Sensor voltage U ( +/- 4 V eff / 6 V pp Safety data Maximum voltage U o =.3 V I o = 300 ma external L o 0. mh external capacity C o 4. μf AK00 III en.8 mh 3 μf 058E0 Safety s /

22 Two-channel safety s Series 00 Series 00 Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Back-up fuse Label carrier 0E00 for all safety s of Series 00, 00 and 004 Packaging unit: 5 pieces Labelling sheet 00E00 perforated, for automatic inscription Format: DIN A Adapter 0E Clamping base, moulded material 0E DIN rail 04E00 NS 35 / 5 (available by the metre) Protective conductor terminal 03856E00 USLKG 5 (clamping range ( 4 mm ) Earthing terminal 06E00 USLKG 6 N (clamping range ( 6 mm ) Fuse holder 06E Insulation and fastening material 07E00 for mounting rail NS 35/ E00 / Safety s AK00 III en

23 Two-channel safety s Series 00 Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations 7 mm /. 83 " 03 mm / 4.06 " mm / 0.4 " 7 Safety s 00, 00, 004 0E00 80 mm / 3.5 " 5 mm / 3.74 " 76 mm / 3.00 " Safety 00, 00, 004 mounted on the mounting rail LV 35/5 030E00 66 mm.60 " 03E00 Safety 00, 00, 004 mounted on the mounting rail LV 3 with adaptor and clamping base made of moulded material Safety 00, 00, 004 mounted on mounting plate with adaptor We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 38 mm. " 66 mm.60 " 38 mm. " 033E AK00 III en Safety s /3

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series > Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Analog Universal Module HART for Zone 2 Series 9468/33

Analog Universal Module HART for Zone 2 Series 9468/33 > 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

Digital Input Output Module for Zone 1 Series 9470/32

Digital Input Output Module for Zone 1 Series 9470/32 www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471 > 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels

More information

Digital I/O Coupler (4-wire) Series 9413/21

Digital I/O Coupler (4-wire) Series 9413/21 Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic

More information

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5. Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/. Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration

More information

Safety Barriers 2/1. Hazardous area. 250 V max I.S.

Safety Barriers 2/1. Hazardous area. 250 V max I.S. /0 Safety barriers Exchangeable back-up fuse for all safety barriers Snap-on mounting on rails: simultaneous connection to potential equalisation/ ground Simple selection: application specific single and

More information

Remote I/O. 74 Remote I/O. Remote I/O System

Remote I/O. 74 Remote I/O. Remote I/O System System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP Engineering Guideline pac-carriers Type 9195 for Yokogawa Centum VP pac-carrier Type 9195 2 Engineering Guideline / Yokogawa Centum VP 26.0.2018 pac-carrier Type 9195 Integrated solutions for Yokogawa

More information

Signal Beacon - LED Series 6162

Signal Beacon - LED Series 6162 www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure

More information

Control Unit Series 8208

Control Unit Series 8208 > Installation of various components such as Snap action switch Potentiometer Relay Time relay Diodes Fuses Resistors www.stahl.de 01776E00 Components of various functions such as diodes, resistors, fuses

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

TR 104, TR 104-Ex Rail mounted Temperature Transmitters Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. HiC2441. SL2 1b. Termination Board SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.

More information

Technical Information Barrier RB223

Technical Information Barrier RB223 TI00132R/09/EN/13.14 71275790 Products Solutions Services Technical Information Barrier RB223 One or two-channel barrier Loop-powered barrier for the safe separation of 4 to 20 ma standard signal circuits

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

Pressure transmitter AKS 32 and AKS 33

Pressure transmitter AKS 32 and AKS 33 Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS

More information

Assembly. Front view. Parametrization interface. Power Bus

Assembly. Front view. Parametrization interface. Power Bus Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and

More information

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features

100/200/400 t. Self-centering pendulum lead cells. Data sheet. Special features C16A 100/200/400 t Self-centering pendulum lead cells Special features - Self restoring function - Nominal (rated) loads: 100 t, 200t and 400t - Simple installation - Rust resistant materials, laser welded,

More information

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web: -

MZB SERIES. Intrinsically Safe Shunt Diode Safety Barriers. Phone: Fax: Web:  - MZB SERIES Intrinsically Safe Shunt Diode Safety Barriers Turck of Intrinsically Safe Shunt Diode Safety Barriers New series of Zener Barriers include a wider product range for more flexibility in more

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET TTR200 Rail-mount temperature transmitter 2 TTR200 RAIL-MOUNT TEMPERATURE TRANSMITTER DS/TTR200-EN REV. D Measurement made easy Temperature transmitter

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

OPTITEMP TT 10 C/R Technical Datasheet

OPTITEMP TT 10 C/R Technical Datasheet OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

TTH200 Head-mount temperature transmitter

TTH200 Head-mount temperature transmitter Change from one to two columns Data Sheet DS/TTH200-EN Rev. B TTH200 Head-mount temperature transmitter Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made

More information

SITRANS T measuring instruments for temperature

SITRANS T measuring instruments for temperature SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Rosemount 648 Wireless Temperature Transmitter

Rosemount 648 Wireless Temperature Transmitter Rosemount 648 Wireless Temperature Transmitter with Rosemount X-well Technology Product Data Sheet July 2016 00813-0100-4648 Rev GD Rosemount X-well Technology provides accurate process temperature without

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Signal conditioner - MACX MCR-UI-UI-NC

Signal conditioner - MACX MCR-UI-UI-NC Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's documentation. Our General Terms of Use for Downloads are valid

More information

MACX MCR-EX-SL-RPSSI-I

MACX MCR-EX-SL-RPSSI-I Extract from the online catalog MACX MCR-EX-SL-RPSSI-I Order No.: 2865340 Ex-i repeater power supply and input isolation amplifier, HART. Sends fed or active 0/4-20 ma signals from the Ex area to a load

More information

2002 IS Catalog. Page

2002 IS Catalog. Page Page Introduction... 95 Current Repeaters/Drivers (Single-channel) KFD0-CS-Ex1.50P (Transmitter, positioner and indicator)... 96 KFD0-CS-Ex1.51P (Positioner and fire detector)... 97 KFD0-CS-Ex1.52 (Current

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194 DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General

More information

Temperature Measurement

Temperature Measurement Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective

More information

FC Series Signal Conditioners

FC Series Signal Conditioners FC Series Signal Conditioners FC-33 DC Selectable Signal Conditioner with 3-way isolation Field configurable input and output ranges of 0-5V, 0-10 V, 0-20 ma and 4-20 ma with 1500 VDC isolation between

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

NEW. Datasheet. ACT20M Signal Isolation and Conversion

NEW. Datasheet. ACT20M Signal Isolation and Conversion Datasheet ACT0M Signal Isolation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Featuring worldwide approvals

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

Coupling Relays and Converters

Coupling Relays and Converters Overview Area of application In automation and control engineering it will always be necessary to work with analog signals. The interfaces for analog signals that have established themselves as the standard

More information

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

onlinecomponents.com

onlinecomponents.com Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common

More information