Motor Protection Circuit Breaker Series 8146/5-V27
|
|
- Oswin Tucker
- 5 years ago
- Views:
Transcription
1 > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release > Robust enclosure made of glass fibre reinforced polyester resin > Optionally available with undervoltage release shunt trip ammeter auxiliary contacts 0966E00 Motor protection circuit breakers of series 846/5-V7 are used where high short circuit currents are to be controlled and to protect both Ex e and Ex d motors. These breakers are suitable to protect lines and systems and can basically be used without a back up fuse at 400 V. Breakers are operated by rotary actuators enabling safe switching and also clearly identifying the switching position. ATEX / IEEx Zone 0 0 For use in x x x x Webode 846N Load Disconnect Switches and Motor Starters /
2 Selection Table Version urrent adjustment range Additional device Order number Weight Motor protection circuit breaker without accessories, kg A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V , A without 846/5-V , A N + NO 846/5-V ,50 On request: ircuit breakers for the current adjustment range A (Type 855) Further accessories e. g. shunt trip, ammeter, additional auxiliary contacts ( N + NO) / Load Disconnect Switches and Motor Starters
3 Selection Table Version D U < L L L3 3 5 I > I > I > Motor protection circuit breaker with undervoltage release, urrent adjustment range Rated operational voltage U e A 30 V A A 30 V A A 30 V A A 30 V A A 30 V A....6 A 30 V A 50 / 60 Hz A 30 V A 4 6 D T T T3 Auxiliary contacts Order number Weight kg without 846/5-V ,60 N + NO 846/5-V ,60 without 846/5-V ,60 N + NO 846/5-V ,60 without 846/5-V ,60 N + NO 846/5-V ,60 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,630 N + NO 846/5-V ,630 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,800 N + NO 846/5-V ,700 Load Disconnect Switches and Motor Starters /3
4 Selection Table Version D L L L3 3 5 U < I > I > I > urrent adjustment range Rated operational voltage U e A 30 V A A 30 V A A 30 V A A 30 V A A 30 V A A 30 V A A 30 V A 4 6 D T T T3 Auxiliary contacts Order number Weight kg without 846/5-V ,900 N + NO 846/5-V ,800 without 846/5-V ,800 N + NO 846/5-V ,800 without 846/5-V ,800 N + NO 846/5-V ,800 without 846/5-V ,800 N + NO 846/5-V ,800 without 846/5-V ,800 N + NO 846/5-V ,800 without 846/5-V ,800 N + NO 846/5-V ,800 without 846/5-V ,000 N + NO 846/5-V ,000 without 846/5-V ,000 N + NO 846/5-V ,000 without 846/5-V ,000 N + NO 846/5-V ,000 without 846/5-V ,350 N + NO 846/5-V ,350 without 846/5-V ,350 N + NO 846/5-V ,350 without 846/5-V ,350 N + NO 846/5-V ,350 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,700 N + NO 846/5-V ,700 without 846/5-V ,400 N + NO 846/5-V ,400 without 846/5-V ,400 N + NO 846/5-V ,400 without 846/5-V ,400 N + NO 846/5-V ,400 without 846/5-V ,400 N + NO 846/5-V ,400 without 846/5-V ,400 N + NO 846/5-V ,400 without 846/5-V ,400 N + NO 846/5-V ,400 /4 Load Disconnect Switches and Motor Starters
5 Explosion Protection Global (IEEx) Gas and dust IEEx PTB Ex d e II T6... T4 Gb Ex tb III T80... T30 Db Europe (ATEX) Gas and dust PTB 0 ATEX 04 E II G Ex d e II T6... T4 Gb E II D Ex tb III T80... T30 Db Note Type Adjustment range T Gas T Dust ertifications and certificates ertificates IEEx, ATEX, anada (SA), Kazakhstan (TR), Korea (Ks), Russia (TR), Ukraine (TR), Belarus (TR) Technical Data Mechanical data Degree of protection IP66 according to IE/EN 6059 Enclosure material Polyester resin, glass-fibre-reinforced, dark grey, similar to RAL 704 Surface resistance ( 0 9 O, impact strength ) 7 J, flame-resistant, self-extinguishing according to IE-9-, UL 94, ASTM D Mounting / Installation Mounting orientation Any onnection 846/5-V7-, 846/5-V7-846/5-V7-3, 846/5-V /5-V7-5, 846/5-V /5-V7-846/5-V7-846/5-V /5-V /5-V /5-V A A A A A T6 T5 T4 T6 T A T6 80 Directly to the fitted components Main contact mm, finely stranded mm, solid Auxiliary contact mm, finely stranded mm, solid On terminal blocks mm, finely stranded mm, solid Please note: ompare the cable diameter with the terminal area of the cable entry Switch insert Electrical data Rated operational voltage Rated operational current Switching capacity Service life electrical mechanical Main contacts max. 690 V A, 50/60Hz A Depending on the selected adjustment range (A) 30 V 400 V 500 V 690 V 7.0 kw.4 kw 6 kw kw 0 5 operating cycles 0 5 operating cycles 3-pole Load Disconnect Switches and Motor Starters /5
6 Technical Data Short-circuit protection Thermal overcurrent release Electromagnetic quick release Adjustment Highest rated current of the short circuit fuse if I is > I S range from at 30 V A at at 440 V A at at 690 V A X... Y I S gg, am I S gg, am I S gg, am I S gg, am I S gg, am A up Short-circuit proof, no back-up fuse needed up to I = 00 ka A A 40 ka 5 A A 60 ka 35 A / 0 ka 40 A 40 A A 70 ka 50 A 40 ka 50 A 7 ka 40 A A 50 ka 80 A 30 ka 80 A 5 ka 50 A A 75 ka 80 A 45 ka 80 A 7 ka 80 A 4.5 ka 50 A A 60 ka 00 A 40 ka 00 A ka 00 A 4 ka 50 A A 55 ka 00 A 35 ka 00 A ka 00 A 3.5 ka 50 A A 50 ka 5 A 30 ka 5 A 0 ka 5 A 3 ka 50 A I S = rated short-circuit breaking capacity I = projected short-circuit current at mounting location Depending on the adjustment range of the switch, adjustable on the switch See tripping characteristic curve urrent ranges Operate value set at factory A I n A I n A I n A I n Ambient conditions Ambient temperature range Switch insert Mechanical data Switching handle Auxiliary contacts Device version Electrical data Rated operational voltage U e Rated operational current undervoltage release Electrical data Function Pick-up voltage Drop-out Power consumption Inrush Holding Shunt release Electrical data Function Pick-up voltage Relative duty cycle Power consumption Inrush Holding Ammeter -0 to +40 Designation: 0 - I; can be locked in the 0-position with three padlocks olour: Standard: black handle, black protective collar Special version: red handle, yellow protective collar (for EM-STOP function) Optional: without; N + NO; Ns + NOs max. A-5: 4 V /.5 A; 30 V / A; 400 V / A D-3: 4 V /.5 A; 60 V /.5 A; 0 V / 0.6 A; 0 V / 0.5 A In case of voltage interruption, the moulded case circuit breaker triggers, preventing an unwanted restart of a motor, for example ) 0.85 x U c x U c 0.9 VA 0.9 VA Used for tripping the moulded case circuit breaker remotely by applying an actuating voltage ) 0.85 x U c Switches off automatically via integrated contact switch V: VA; V: VA; V: VA Switches off automatically via integrated contact switch /6 Load Disconnect Switches and Motor Starters
7 Technical Data Device version Type 8405, front dimensions 64 mm x 64 mm Electrical data Movement Moving iron measuring instrument, class.5; direct measuring; overload scale : Measuring range Depending on the adjustment range of the switch Overload capacity x I e 5s, 50 x I e s Tripping behaviour Adjustment Tripping time of the motor protection switch with range of the motor protection switch times rated current. 3-pole from cold state.. A... A s s s s s s ) Multiples of the rated operational current ) Tripping time 3) -pole 4) 3-pole 5) Electromagnetic tripping 050E00 05E00 Load Disconnect Switches and Motor Starters /7
8 Tripping behaviour 05E00 053E00 ) Multiples of the rated operational current ) Tripping time 3) -pole 4) 3-pole 5) Electromagnetic tripping 054E00 055E00 /8 Load Disconnect Switches and Motor Starters
9 Tripping behaviour 056E00 057E00 058E00 059E00 ) Multiples of the rated operational current ) Tripping time 3) -pole 4) 3-pole 5) Electromagnetic tripping Load Disconnect Switches and Motor Starters /9
10 Tripping behaviour 060E00 06E00 ) Multiples of the rated operational current ) Tripping time 3) -pole 4) 3-pole 5) Electromagnetic tripping 06E00 063E00 /0 Load Disconnect Switches and Motor Starters
11 Dimensional Drawings (All dimensions in mm [inches]) Ð subject to modifications 04793E E E00 846/5-V7-846/5-V7-846/5-V7-3, 846/5-V /5-V7-5, 846/5-V7-6 able entries Type Additional equipment ) Series 86 cable entries Series 890 stopping plugs M5 x.5 M3 x.5 M5 x.5 846/5-V7- Without With 3 A, B, 846/5-V7- Without With 3 A, B, 846/5-V7-3, Without 846/5-V7-4 With 846/5-V7-5, 846/5-V A Without With A Without With M5x.5for cable Ø mm M3 x.5 for cable Ø 9... mm ) Auxiliary contact, undervoltage release, shunt trip 3 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. A, B, 04796E00 Load Disconnect Switches and Motor Starters /
Signal Beacon - LED Series 6162
www.stahl.de > Versions rotating mirror beacon rotating beacon beacon with double flash (9 + 5 J) flashing beacon (15 J) LED-continuous beacon LED-rotating beacon > Seawater resistant aluminium enclosure
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationActuators Series 8602/3
> Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationIsolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationLocal control stations for Zone 1 and Zone 21. Features. Description
Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More information3 - Protection components Circuit-breakers
Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationMotor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A
DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationTeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7
Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationCEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1
CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG
More informationJ7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947
Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationPHOENIX CONTACT
Electronic circuit breaker CLIPLINE Data sheet 102898_en_03 PHOENIX CONTACT 2010-12-17 1 Description The electronic circuit breaker can be used in applications that cover all aspects of the switched-mode
More informationTechnical Data Accessories MCCBs Ex9M.
Auxiliary and signal contact units AX21, AL21 Contact units for auxiliary and signal contact functions are suitable for both M1 and M2 frame sizes It is possible to use ap to two units of AX21 plus 1 unit
More informationSiemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)
Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the
More informationMiniature Circuit Breakers B4/B6/B10, Residual Current Devices & Isolating Switches
Miniature ircuit reakers 4//, esidual urrent evices & Isolating Switches The IMO range of miniature circuit breakers have been designed for protection of electrical installations against overload and short
More informationAir damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control
s OpenAir Air damper actuators SD...1A Electric motor-driven rotary actuators for open-close, three-position and modulating control 2 m nominal torque Operating voltage / DC 24 48 V or AC 100 240 V ~ Prewired
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationT e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker
T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion
More informationPKZ 2 Manual Motor Protectors Technical Data
08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3
More informationComponents for safety applications
Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages
More informationPHOENIX CONTACT
Selective circuit breaker CLIPLINE Data sheet 100464_en_05 PHOENIX CONTACT 2009-11-17 1 Description The electronic circuit breaker, which has a design width of just 12.5 mm, selectively protects all 24
More informationJ: Emergency lighting (optional) L: pole type X: ceiling type
Lighting Technology Light Fittings for Fluorescent Lamp BAY Series Explosion-proof Light Fittings for Fluorescent Lamp Explosion protection to -CENELEC -IEC -NEC Can be used in Zone and Zone Zone and Zone
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationType: DILM40(RDC24) Article No.:
Type: DILM40(RDC24) Article No.: 277780 Ordering information Rated operational current AC 3 400 V I e A 40 Max. rating for three phase motors, 50 60 Hz AC 3 230 V Max. rating for three phase motors, 50
More informationModeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS
OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping
More informationOpen Type Without Enclosure
Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General
More informationNZMH4, NZM(H)6(B), NZM(H)9, NZM12 Technical Data
Circuit Breakers, 09/098 Molded case circuit breakers 3 pole NZMH 4-...-C 1) NZM6B.../ZM6A...- Frame size A 80 125 125 IEC 60 947-2 Electrical Ratings Rated impulse withstand voltage U imp V 8000 8000
More informationManual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool
echnical data sheet LMA-MF-P Multifunctional damper actuator for operating air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx.
More information(1,5 modules per pole)
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 DX 3 MCB 25kA 80A to 125A CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...
More informationLiquid level monitors and controls
Liquid level monitors and controls ontent M-ENE, M-ENE MAX... / 8 M-ENS... / 83 M-ENS UP/DOWN... / 84 M-ENN... / 85 M-ENN UP/DOWN... / 86 Accessories for liquid level relays... / 87 Technical data M-ENE,
More informationEx-control switch Typ 294 without and Typ 295 with measuring instrument
Ex-control switch GHG 9 and GHG 9 GHG 9 GHG 9 Technical data Ex-control switch Typ 9 without and Typ 9 with measuring instrument with GHG 9 switch with GHG switch Marking accd. to 0//EU D II G Ex ed ia
More informationC 1. SPECTRONIC SP - Air circuit breakers. Summary. C.3 General characteristics. C.4 Fixed circuit breaker. C.5 Withdrawable circuit breakers
SPETRONI SP - Air circuit breakers Summary.3 General characteristics.4 Fixed circuit breaker.5 Withdrawable circuit breakers.6 haracteristics.7 RMS 7: protection and control unit.10 RMS 9: protection and
More informationModular equipment. Presentation, standards. Standard contactors TeSys GC
Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on
More informationFor Immediate Delivery call KMParts.com at (866)
Moeller Wiring Manual / Page Overview - ON-OFF Switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-speed switches - Interlock
More informationServomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16
MZ Servomotor for butterfly valves VF, VFH delta-elektrogas.com EE157-01/16 MZ Servomotor Contents Description.... 2 Features........ 2 Functioning and application..... 3 Technical specifications......
More informationSeries P. Applications
Ratings 25 800 VA Voltage Primary 230 / 400 / 460 V range Secondary 6 / 12 V 12 / 24 V 24 / 48 V 115 / 230 V Voltage selection by means of metal connection bridges, offering the full rated power at any
More informationTechnical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC
echnical data sheet SMA-PC Parameterisable damper actuator for adjusting air dampers in ventilation and air-conditioning systems in buildings Air damper size up to approx. m orque 0 Nm Nominal voltage
More informationOverview of types. Technical data
echnical data sheet SHA-.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control dampers
More informationSafety switches with slotted hole lever
Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50
Technical Information Nivotester 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50 Area of application The Nivotester is suitable as a 1-channel switch amplifier for the Soliwave
More informationType: DILEM 10(220V50HZ,240V60HZ) Article No.:
Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230
More informationAir damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control
s OpenAir Air damper actuators GDB..1E Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC 24 48 V or AC 100 240
More informationAuxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)
Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,
More informationDISCONNECT SWITCHES. UL Listed CSA Certified
POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole
More informationLC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition
Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition
More informationType: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information
Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationEA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters
EA16, EB16, EA17, EA19, EA12 MOVING-IRON METERS Ammeters and Voltmeters EA12 EA19 EA17 EA16 EB16 APPLICATION EA16, EB16, EA17, EA19 and EA12 moving-iron meters are intended for measuring AC voltage or
More informationType: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information
Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400
More informationPower supply CP-D 24/4.2 Primary switch mode power supply
Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk LED / nllk V-CG-S LED DALI Ex-Linear Light Fittings Linear
More informationMiniature circuit-breakers S 280 UC series. System pro M. Technical data
Technical data 11 Robbie Rd. / Avon, MA 02322 T:(508)513-1000 F:(508)513-1100 70 Ernest St. / Providence, RI 02905 T:(401)781-7100 www.controllerservice.com System pro M Prior to connection of aluminum
More informationMicro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13
Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC
More informationAEG Low Voltage Component
AEG Low Voltage omponent Technology transfers reliable power We are striving to create a peaceful and comfortable life for you. AEG: We believe that power system can be very simple. Main distribution system
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings Sicherheit, auf die Sie sich verlassen können nllk LED Ex-Linear LED Light Fittings for Zone 2/22 nllk Ex-Linear Light Fitting Linear Light Fitting with LED Tubes
More informationSicherheit, auf die Sie sich verlassen können
Explosion protected linear light fittings CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Ex-Linear LED Light Fittings for Zone 2/22 Ex-Linear LED Light Fittings Linear LED Light Fittings
More informationTop wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations
Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching
More informationSicherheit, auf die Sie sich verlassen können
CEAG Products Ex-emergency lighting CROUSE-HINDS SERIES Sicherheit, auf die Sie sich verlassen können Explosion protected safety luminaire for Zone 1/2 und 21/22 Explosion protected safety luminaire Zone
More informationConfigured air damper actuators 6FU11xx-xDxxx-xxxx
s OpenAir Configured air damper actuators 6FU11xx-xDxxx-xxxx Electronic motor driven actuators for open-close, three-position and modulating control Nominal torque 5 Nm Operating voltage AC 24 V ~ / DC
More informationLighting Technology. Zones 2; 21&22. Light Fittings for Fluorescent Lamp. BnY81 Series Explosion-proof Light Fittings for Fluorescent Lamp
Lighting Technology Light Fittings for Fluorescent BnY81 Series Explosion-proof Light Fittings for Fluorescent Catalogue number logic BnY81- x J: Emergency lighting (optional) X: ceiling type G: pendant
More informationUTE100 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTE100 NT FMU 100A 3P LL LSIS UL MCCB
PRODUCT CATALOG SUSOL SUPER SOLUTION SELECTION GUIDE UTE00 CATALOG NUMBERING [PRODUCT SELECTION] UTE00 NT FMU 00A 3P LL UL SERIES & FRAME: Susol 00AF PERFORMANCE Rating 80% 00% ka SUFFIX UL : UL 20/ 240Vac
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationFunctional Range. IWE - Earth Fault Relay. C&S Protection & Control Ltd.
Functional Range - Earth Fault Relay C&S Protection & Control Ltd. 2 Contents Page No. 1. Application 2. Operating Principle. Current Transformer Connections 5. Connections, Contact Arrangement and Setting
More informationCapacitor Switching Contactors
Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..
More informationNivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier
Technical Information Nivotester FTR325 1-channel switch amplifier for the Soliwave M microwave barrier Area of application The Nivotester FTR325 is suitable as a 1-channel switch amplifier for the Soliwave
More informationControl stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M
Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard
More informationElectronic Circuit Breaker with reset input ESS20-1..
Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and
More information120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240
Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to
More informationPower consumption In operation At rest For wire sizing. Auxiliary switch NRF24A-SR-S2 NRF24A-SR-S2-O
echnical data sheet NRF24A-SR-S2(-O) Modulating rotary actuator with emergency function for 2- and 3-way ball valves orque or ue 10 Nm Nominal voltage AC/DC 24 V Control: modulating DC 0... 10 V Position
More informationPressure transmitter AKS 32 and AKS 33
Data sheet Pressure transmitter AKS 32 and AKS 33 AKS 32 and AKS 33 are pressure transmitters that measure a pressure and convert the measured value to a standard signal: y 1 5 V DC or 0 10 V DC for AKS
More informationMini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks
Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors
More informationDPX TM MCCBs LP* Description Cat. nos. ` / Pack Unit
DPX TM MCCBs Description Cat. nos. ` / Pack DPX TM MCCBs Description Cat. nos. ` / Pack Auxiliary contact / Fault signalling contact DPX 125,160,250 ER 0261 60 804 1/24 250, 630, 1600, 1250 Under voltage
More information