Liquid Level Switches
|
|
- Sharleen Day
- 5 years ago
- Views:
Transcription
1 Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange, hygienic thread Material: Stainless steel.4404 Viscosity: max mm /s No moving parts Insensitive to plant vibrations ATEX version KOBOLD companies worldwide: ARGENTINA, AUSTRIA, BELGIUM, CANADA, CHILE, CHINA, COLOMBIA, CZECHIA, FRANCE, GERMANY, GREAT BRITAIN, INDIA, IRAN, INDONESIA, ITALY, MALAYSIA, MEXICO, NETHER LANDS, PERU, POLAND, SINGAPORE, SLOVAKIA, SPAIN, SWITZER LAND, THAILAND, USA, VENEZUELA, VIETNAM KOBOLD Messring GmbH Nordring -4 D-6579 Hofheim/Ts. +49(0) Fax +49(0) info.de@kobold.com Internet: Model: NWS 5
2 N Description The KOBOLD liquid level switch NWS is designed as a and 3-wire switch and can be universally used in vessels and pipelines. The NWS operates on the tuning fork principle in air at resonance frequency. A piezoelectric crystal is used for excitation of oscillations and for monitoring the actual oscillation frequency. When the fork is immersed in liquid, the frequency changes: this change is detected electronically and the output signal is changed. The NWS operates as a two-wire switch in series with the load. The simple electronic switch is operated by the liquid. The NWS can also be connected to a PLC through a third terminal. Special features The NWS has an output state indicator with an LED that can be seen though a lens in the cover. The LED flashes about once a second when the NWS has switched off and is permanently illuminated when the NWS is switched on. The LED is an optical confirmation that the NWS is working correctly and the condition of the wet side is correctly displayed. The NWS can be set as upper or lower limiter with a mode selector. Applications Oils Water Paints and transparent inks Sauces Milk Liquids containing carbon dioxide Foamed oils Technical Details Material Fork: stainless steel.4404 Process connection: stainless steel.4404 Electronic housing: NWS-...00: PAG, glass-fibre-reinforced cover with window, 330 rotatable all other types: stainless steel.430 Process connections: pipe thread DIN EN 06-, NPT thread, Tri-Clamp, pipe connection DIN 85 (sanitary connection), aseptic-connection DIN 864, DRD flange, flange B 5 PN 40 DN 57, flange B 50 PN 40 DN 57, flange ANSI B ", 300 lbs, flange ANSI B ", 300 lbs Protection: plastic housing: IP 65 (NWS-...00) stainless steel housing, plug connection: IP 67 stainless steel housing, cable connection: IP 68 Max. operating pressure: Max. medium temp.: Min. medium density: Ambient temperature: Min. immersion depth for switch points: Power supply NWS : 45 bar flange connection: see pressure steps 30 C (NWS ) 90 C (for all other NWS) short-time 50 C for CIP (valid for all models NWS) 800 g/l (lower on request) -0 C C mm (marker on fork) V DC / AC (50/60 Hz); -wire; 4 V DC, 3-wire NWS-...3/4/W/H..: 4 V DC, 3-wire The NWS is ideal for hygienic and sterile applications and for NWS-...E..(ATEX): Isolation Switching Amplifier to CIP cycles up to 50 C. IEC (Namur) necessary (for example: REL-6) ATEX version: Delay: s wet /dry s dry / wet Type of protection: intrinsically safe ia Designation: II G EEx ia II C T6 Viscosity: 5000 mm /s max. at 5 C (influence on the response time) To use in connection with intrinsically safe Isolation Switching Amplifier according to Hysteresis: 4 mm vertical, mm horizontal IEC Repeatability: ± mm Weight: 0.5 kg (for R 3 4 and 3 4 NPT) 5 /07-00
3 Electrical connection NWS wire 4-40 V AC/DC, serial Load, I max 500 ma NWS wire, V S = 4 V DC Output PNP: U HIGH 6.5 V; U LOW.5 V; I max 500 ma 500 ma PE PE 500 ma N Last L V+ 4 N 3 V- 4 Load NWS-...3/4 (4 V DC ) NWS-...W/H (WHG in preparation) NWS-...E... (ATEX) GND (n.c.) + Vs (n.o.) + Vs E + S (n.o.) + Vs (n.c.) GND (n.o.) Switch out GND Switch out -S + S (n.c.) Wiring diagram Colour of core NWS-...3/4 NWS-...W/H Lead-/ Pinnumber NWS-...E (ATEX) brown blue black + Vs (n.o.) / GND + Vs GND / + Vs (n.c.) GND Swich out Swich out S (n.o.) Earth S + S (n.c.) Wiring examples NWS-...E... with Power supply unit acc. to IEC Plug Mx E + S (n.o.) + Isolation Switching Amplifier IEC (for example: REL-60xx) S + S (n.c.) Cable.5 m Lead No. (Lead No. 4) + Isolation Switching Amplifier IEC (for example: REL-60xx) Lead No. Lead No
4 Order Details (Example: NWS-R ) Connection Model Electrical connection Sensor version N R 3 4 male thread NWS-R0... R male thread NWS-R5...* 3 4 NPT male thread NWS-N0... Plastic housing 00 = V AC/DC Cable gland/ terminal connection 0060 =60 mm (only for NWS-T / NWS-L / NWS-H) NPT male thread NWS-N5...* DIN flange DN 5 NWS-F5... DIN flange DN 50 NWS-F50...* " ANSI flange NWS-A5... " ANSI flange NWS-A50...* Tri-Clamp DN 40 NWS-T40... Tri-Clamp DN 50 NWS-T50... Sanitary conn. DN 40 (DIN 85) NWS-L40... Sanitary conn. DN 50 (DIN 85) NWS-L50... Aseptic conn. DN 50 (DIN 864) NWS-H50... DRD Ø 5 mm flange NWS-DZ... St. steel housing/plug connection 3S = 4 V DC, PNP, plug Mx 4S = 4 V DC, NPN, plug Mx WS***= 4 V DC, WHG, PNP, plug Mx HS***= 4 V DC, WHG, NPN, plug Mx ES= ATEX approval, plug Mx St. steel housing/cable connection 3F = 4 V DC, PNP,.5 m cable 4F = 4 V DC, NPN,.5 m cable WF***= 4 V DC, WHG, PNP,.5 m cable HF*** = 4 V DC, WHG, NPN,.5 m cable EF = ATEX approval,.5 m cable 0070 = 70 mm standard version, short (not for NWS-T / NWS-L) 07** = 7 mm extended 0300**= 300 mm sensor 0500**= 500 mm sensor 000**= 000 mm sensor XXXX**= please specify special length 4-position in mm (max mm) Special connection NWS-YYY... **only models marked with * are available with sensors in extended version. ***WHG-approval in preparation. Dimensions NWS V AC/DC Plastic housing NWS-...3S/4S NWS-...WS/HS 4 V DC Plug connection NWS-...3F/4F NWS-...WF/HF 4 V DC Cable connection NWS-...ES ATEX Plug connection NWS-...EF ATEX, Cable connection 09 ø 80 ca. 84 3,5 ø
5 Dimensions (continued) NWS (Standard, short) 0 3 NWS-R NWS-N (extended) N 0 NWS-T... Tri-Clamp 0 NWS-F... / NWS-A... Flange version approx L 4 AF L3 L L 3 DN 5 / PN 40 DN 50 / PN 40 ANSI " 300 lbs ANSI " 300 lbs 8 approx approx. 95 approx. 4.4 approx. 9 NWS-L... Sanitary connection (DIN 85) 0 NWS-H... Aseptic connection (DIN 864)
6 For Temperature Measurement and Temperature Monitoring... N... please refer to our brochure»t+t«kobold Manufacturer for Innovative Instrumentation
Operating Instructions for Level Switch Tuning Fork Principal. Model: NWS
Operating Instructions for Level Switch Tuning Fork Principal Model: NWS 1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Use
More informationLevel Sensors Reed Contact Chain
Level Sensors Reed Contact Chain measuring monitoring analysing Measuring length: Measuring accuracy: 0.5% for L = 2000 mm Pressure: max. 20 bar Temperature: max. 130 C Connection: G 3 8 to G 2 flange:
More informationKAL-K. Electronic Flow Monitor. for liquids. Range: approx cm/s. p max : 100 bar. Temperature of medium: C Option: 0...
Electronic Flow Monitor for liquids measuring monitoring analysing KAL-K Range: approx. 4-200 cm/s p max : 100 bar Temperature of medium: -20... +80 C Option: 0... +120 C Process connection: G ¼, G ½,
More informationMagnetic Inductive Flowmeter
Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange
More informationLTS. Resisitve Temperature Sensor hygienic design. Temperature. Measuring range: C Accuracy Class A according to DIN IEC 751 p
Resisitve Sensor hygienic design measuring monitoring analysing LTS Measuring range: -50 +250 C Accuracy Class A according to DIN IEC 751 p max : 10 bar Process connection: G ½ standard, G ½ or M cavity
More informationMeasuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...
Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000
More informationFull Metal Variable Area Flowmeter and Counter Model BGF
Full Metal Variable Area Flowmeter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF OO Measuring range: 10-100... 6000-60000 l/h water 0.3-3.0... 170-1700 m³/h air (20
More informationBGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases
All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy
More informationDUK. Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit
Ultrasonic Flowmeter/ -Monitor/-Counter/-Dosing Unit measuring monitoring analysing DUK Measuring range: 0.08-0. - 630 L /min Accuracy: ±. % of F.S. Range span: 0 p max : 6 bar; t max : 90 C Connection:
More informationElectronic Flow Monitor
Electronic Flow Monitor for Liquids measuring monitoring analysing Range: approx. 4200 cm/s Max. pressure: 100 bar Temperature of medium: 20...+80 C Option: 0...+120 C Processconnection: G 1 4...G 1 1
More informationCOMPACT-LINE. Transmitter for ph-value
Transmitter for ph-value measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential) and temperature Simple
More informationCoriolis Mass Flow Meter Model TM
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationLCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version
Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement
More informationAccuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040) Material: (316 L) / (316 Ti)/ Hastelloy C-22
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing TMU S5 Measuring range: 0-60 kg/h 0-2200 t/h water Accuracy: ± 0.1 % of reading ±zero point stability (from liquids up to TMU-x040)
More informationElectromagnetic flowmeter in all metal design Model MIM
Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and
More informationDVZ. Vortex Flowmeter Compact. for low viscosity liquids
Vortex Flowmeter Compact for low viscosity liquids measuring monitoring analysing DVZ Range: 0. -4. 0-00 L/min Accuracy: ±.% of full scale p max : 0 bar; t max : 80 C Connections: G ¼...G, ¼" NPT..." NPT
More informationKDS. All Metal Variable Area Flowmeter. for Liquids and Gases
All Metal Variable Area Flowmeter for Liquids and Gases measuring monitoring analysing : 0.1-1... 20-200 water 3-30 Nm3/h... 600-6000 Accuracy: ±3 % of full p max : 420 bar; t max : 130 C Connection: ¼"
More informationNGR. Guided Wave Radar Level Transmitter
Guided Wave Radar Level Transmitter measuring monitoring analyzing NGR For Liquids Operates Independent of Density, Temperature, Pressure, Humidity, and Conductivity Standard Measuring Length: 6. Ft (Longer
More informationInsertion Thermocouples with Bayonet Lock
Insertion Thermocouples with Bayonet Lock measuring monitoring analysing Measuring ranges: 0... +400 C Bulbs in stainless steel 1.4571 NiCr-Ni or Fe-CuNi thermocouples Accuracy class 2 (option category
More informationTME. Coriolis Massflowmeter. for liquids and gases kg/h kg/h water. p max. : PN40 t max : C
Coriolis Massflowmeter for liquids and gases measuring monitoring analysing TME OMeasuring O range: 0-60 kg/h 0-60000 kg/h water O O Accuracy: ±0.15 of reading ± zero-point stability OO p max : PN40 t
More informationMEGGITT MOBREY LTD. MOBREY SQUING Vibrating fork liquid level switch. Product data sheet IP202
MEGGITT MOBREY LTD MOBREY SQUING Vibrating fork liquid level switch Universal level switch High level alarm duty Overfilling prevention Intrinsically safe models Marine approved models FEATURES Small &
More informationDUK. Compact Ultrasonic Flowmeter
Compact Ultrasonic Flowmeter measuring monitoring analyzing DUK Measuring Ranges: 0.0... GPM to 0.6...60 GPM Accuracy: ±0.7 % of Reading + ±0.7% of F.S. Turndown Ratio: 0: P max : 30 PSI; T max : 48 F
More informationTemperature Transmitters
Temperature Transmitters measuring monitoring analysing KM O O Wide supply voltage range: 7.5... 5 V DC O O Operation, visualisation and maintenance via PC Universal setting with HART protocol T O O Fault
More informationTUR. Turbine Wheel Flowmeter. Plastic Model for Liquids. Measuring Ranges: GPM or GPM (Water)
Turbine Wheel Flowmeter Plastic Model for Liquids measuring monitoring analyzing TUR TUR with Transmitter TUR with ADI-1 Measuring Ranges: 5.3...88 GPM or 11...440 GPM (Water) Measuring Accuracy: ± 1%
More informationOperating Instructions for Microwave Level Switch. Model: LNM
Operating Instructions for Microwave Level Switch Model: LNM 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating Principle...4 6. Mechanical Connection...5
More informationCOMPACT-LINE. KOBO-RP Transmitter for ORP Model ARM-Z
KOBO-RP Transmitter for ORP Model ARM-Z measuring monitoring analysing COMPACT-LINE Measuring range -1999 to +1999 mv Switchable from ORP to ph ph or mv/orp (Oxidation Reduction Potential) and temperature
More informationCOMPACT-LINE. KOBO-pH Transmitter for ph-value Model APM-Z
KOBO-pH Transmitter for ph-value Model APM-Z measuring monitoring analysing COMPACT-LINE Measuring range ph -1 to 14 Switchable from ph to ORP Display of ph value, mv/orp (Oxidation Reduction Potential)
More informationMIM. Electromagnetic Flowmeter. Compact, All-metal Design
Electromagnetic Flowmeter Compact, All-metal Design measuring monitoring analyzing MIM For Measurement and Monitoring of Conductive Liquids Flow and Temperature Measurement Switching, Transmitting, and
More informationLiquiphant T FTL20H. Technical Information
Technical Information Liquiphant T FTL0H Level limit switch Level limit switch for liquids in the foodstuff industry, compact design, housing made of corrosion-resistant stainless steel Application The
More informationThrough-beam ring sensors
Throughbeam ring sensors Features Wide range of sizes: ring diameters of 10, 15 and 20 mm Metal housings Separate evaluation unit Connection by means of S8 connector Degree of protection IP 63 Adjustable
More informationFrame through-beam sensors
Frame through-beam sensors Features Wide range of sizes: passage sizes from 25 x 23 mm to 300 x 397.5 mm Metal housings Integrated evaluation unit Connection by means of connector Degree of protection
More informationBGF. Full Metal Variable Area Flow Meter and Counter. for horizontal and vertical mounting. Special versions up to 600 bar
Full Metal Variable rea Flow Meter and Counter for horizontal and vertical mounting measuring monitoring analysing BGF Special versions up to 600 bar S2 Measuring range: 10-100... 4000-40000 l/h water
More informationOEM radar transmitter, for aggressive media level measurement
OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type
More informationEXPERT-LINE. KOBO-pH. Transmitter for ph-value and ORP Model APM-X
KOBO-pH Transmitter for ph-value and ORP Model APM-X measuring monitoring analysing EXPERT-LINE Measuring range: ph value: 0 to 14 ORP: -1500 to +1500 mv (0-100%) For general-purpose use with: Analogue
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:
More informationNBK-04. Level Indicator for Tank-Top Mounting
Level Indicator for Tank-Top Mounting measuring monitoring analyzing NBK-04 Max. Measuring Length: 13' pmax: 230 PSI tmax: 250 F Max. Viscosity: 200 cps Connection: ASME B16.5 Flange 2" or 2-½" Material:
More informationBGF. All-Metal Armored Variable Area Flowmeter and Totalizer. for Horizontal or Vertical Mounting
All-Metal Armored Variable Area Flowmeter and talizer for Horizontal or Vertical Mounting measuring monitoring analyzing BGF Measuring Range: 0.044...0.44 to 26.4...264 (Water) 0.176...1.76 to 100...1000
More informationS 4. Vane Flow Meter, Monitor, Counter, Batching System. in modular design for liquids. Measuring accuracy: ± 2.5% f.s. : 100 bar; t max : 80 C.
Vane Flow Meter, Monitor, Counter, Batching System in modular design for liquids measuring monitoring analysing DF S 4 O O Measuring ranges: 0.08-0.50... 40-160 l/min water OO Measuring accuracy: ± 2.5%
More informationSALES SERVICE +358 (0)
SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control
More informationTMU. Coriolis Mass Flow Meter. for liquids and gas
Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationLevel and Pressure. Product Information. Vibrating level switches
Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2
More informationValve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator
Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam
More informationVane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids
Vane Flow Meter, Monitor, Counter, Batching System in Modular Design for Liquids measuring monitoring analysing : DF...D : DF...WM : DF...MA : DF...M Measuring ranges: 0.080.50 to 40160 water Measuring
More informationCoriolis Massflowmeter
Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationDUK COMPACT ULTRASONIC FLOWMETER
DUK COMPACT ULTRASONIC FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Measuring Ranges: 0.0- GPM to 0.6-60 GPM Accuracy: ±. % of F.S. Turndown Ratio: 0: P max : 30 PSI; T max
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationINSTALLATION AND OPERATION MANUAL
Version 2.2 MS1016 MTF SERIES VIBRATING PROBES FOR LIQUIDS AND HYC-PKK-312 SWITCHING ISOLATOR INSTALLATION AND OPERATION MANUAL Hycontrol Limited, Larchwood House, Orchard Street, Redditch, Worcestershire,
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring
More informationECHOTEL 915 series. 2 Wire, current shift Ultrasonic level switch. Worldwide level and flow solutions DESCRIPTION. Compact and universal level switch
ECHOTEL 915 series 2 Wire, current shift Ultrasonic level switch DESCRIPTION Echotel 915 series ultrasonic level controls are 2 wire (24 V DC) integral units which utilize pulsed wave technology to detect
More informationDigital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
More informationDOG-4. Oscillation Flowmeter. for gases. Measuring ranges: m 3 /h air. : PN 40; t max. p max : 120 C
Oscillation Flowmeter for gases measuring monitoring analysing DOG-4 Measuring ranges: 0.12-12... 60-6000 m 3 /h air p max : PN 40; t max : 120 C Connection: flange DN 25... DN 200 Material: stainless
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationwww. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER
www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER 1 www. otech.com.sg EFS801 - CFT181/RFT201 ELECTROMAGNETIC FLOWMETER Accurate, Reliable and Stable Flow Measurement. Measuring Principle The measuring
More informationMagnetic level switches ERH-xx-20
edit. II 2015/ page 5 Magnetic level switches ERH-xx-20 Description 3 Level signalling of the medium having minimum density 0,70 g/cm. The basic version, mounted from the top, is available with 92x92mm
More informationINSERTION paddle wheel flowmeter for continuous flow measurement
INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both
More informationSUPER RGB Sensor. Lustre Detection Sensor Head. is newly developed. CZ-V20 Series. It can detect lustre without being affected by colours CZ-V20
NEW Digital RGB Sensors CZ-V20 Series Lustre Detection Sensor Head CZ-H2 NEW SUPER RGB Sensor Lustre Detection Sensor Head is newly developed Glossy objects Digital RGB Sensor Amplifier CZ-V20 Matt objects
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationMagnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up
Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically
More informationECHOTEL 961/962. Ultrasonic level switches. Loop or line powered D E S C R I P T I O N F E AT U R E S A G E N C Y A P P R O VA L S
ECHOTEL 961/962 Ultrasonic level switches D E S C R I P T I O N The Echotel 961/962 series utilizes pulse signal technology to detect high or low level alarm(s) in a broad range of viscous to light liquids.
More informationDS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor
GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent
More informationprosonic T FMU230, FMU231
Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters
More informationTarget disk flowmeter for liquids and gases
Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight
More informationINLINE flowmeter for continuous flow measurement
INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection
More informationLEVEL Switches RFM-500 RAM-403 RRH-300 RLH-300 RNM-401
Vibrating fork level switches nivoswitch GENERL DESCRITION NIVOSWITCH vibrating fork level switches are suitable for level detection of liquids or granular, powdered solids. Units with parallel vibrating
More informationph or ORP Transmitter
ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes
More informationLEVEL Transmitters. SAP-300 display. Mono cable / Mono rod Mono segmented rod. Twin cable Twin rod Coaxial Pipe
Guided microwave level transmitters GENERAL DESCRITION The Guided Wave Radar level transmitter is designed for continuous level measuring of conductive or non-conductive liquids, pulps and solids. level
More informationDMH. Magnetic Inductive Flowmeter. for Conductive Fluids
Magnetic Inductive Flowmeter for Conductive Fluids measuring monitoring analyzing DMH Measuring Range: 0.29...26.4 to 431.6 43,333 GPM Accuracy: ± 0.3% of Reading ± 0.01% x Q max p max : 580 PSI t max
More informationvega-line price list 2011/12
vega-line price list 0/ Measurement technology for level, switching, pressure vega-line Standard solutions Quickly and price-favourable VEGA world leader in measurement technology VEGA is a world leader
More informationP R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution
P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for
More informationMass Flowmeter CoriolisMaster FCM2000
Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving
More informationOPTIFLUX 5000 Technical Datasheet
OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech
More informationSITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview
Overview Design The transmitter is available in different enclosure to fit any demands: IP67 enclosure for compact or wall mounting IP00 as a 19 insert IP65 for wall mounting IP65 enclosure in stainless
More informationLiquid density: from 0,6 g/ml on. Plastic Level Switch NKP Download PDF datasheet
Differential Pressure Transmitter PAD Measuring range: 0,75-15 mbar...4,137-413,7 bar Connection: ¼ NPT, ½ NPT Housing Material: st. st., Hastelloy-C, Monel, Tantalum, Max. temperature: 120 C Accuracy:
More informationwww.rechner-sensors.com CATALOGUE SerieS 26 - Model range 700/800 Capacitive level sensors for liquids or pastes, for example: Water Oil Ketchup 2 Registration No.: 1327-01 For all transactions, the newest
More information2-Wire. Level Gauge BM 702
KROHNE 09/2001 7.02323.22.00 GR/PRINTO Level Gauge 2-Wire Level-Radar 2-Wire The first and only FMCW Radar Level Gauge with 2-wire technology The non-contact alternative to ageing technologies Maintenance-free
More informationMagnetic Inductive Flow Sensors induq. Series VMI
Magnetic Inductive Flow Sensors induq Series VMI Free Flow! Compact - cost-effective - robust! The induq from SIKA is a trio of extremly compact, low cost, magnetic inductive fl ow sensors. This new product
More informationOVZ. Oval Wheel Flow Meter. for viscous liquids l/min liquid. Measuring accuracy: ± 2.5% f.s. p max : 40 bar; t max : 80 C
Oval Wheel Flow Meter for viscous liquids measuring monitoring analysing OVZ Model: OVZ OMeasuring O ranges:.3-8....6-4 l/min liquid Measuring accuracy: ± 2.5% f.s. p max : 4 bar; t max : 8 Model: OVZ
More informationTechnical Information Smartec CLD18
TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring
More informationMass Flowmeter CoriolisMaster FCM2000
Contents Data Sheet Mass Flowmeter CoriolisMaster FCM2000 Coriolis Mass Flowmeters are used for high precision measurement of mass flow and density. The fluid need not be electrically conductive. No moving
More informationElectromagnetic Flow Transmitter
Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be
More informationJ Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016
J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow
More informationCombiTemp TCR6 Standard RTD temperature sensor
Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water
More informationFLOAT LEVEL SENSOR TFC. Applications. Reference. Features
FLOAT LEVEL SENSOR The label Trafag Industrial Components extends the Trafag brand name to instruments manufactured by qualified partner companies. Trafag Industrial Components complement the genuine Trafag
More informationPSD. Digital Pressure Sensor. LED Display with Switch & Analog Outputs
Digital ressure Sensor LED Display with Switch & Analog Outputs measuring monitoring analyzing SD Measuring Range: 0...30 to 0...7500 SI Temperature Range: -13...185 F Accuracy (at 77 F): ± 0.5 % FS Connection:
More informationDigital flow ELEMENT transmitter for continuous flow measurement
Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single
More informationOperating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601
Operating Instructions for Pressure Sensor with Ceramic Sensor Element Model: SEN-9601 We don t accept warranty and liability claims neither upon this publication nor in case of improper treatment of the
More informationRod probe With coaxial tube reference probe
Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the
More informationSGM LEKTRA LEVEL Measurement Control SGM LEKTRA Capacitive Ultrasonic Radiated microwave Guided Microwave Hydrostatic head Vibration Resistive
level measurement LEVEL SGM LEKTRA produces level measurement instruments for industrial applications and for environmental monitoring. These instruments are divided into two groups: Measurement - Numeric
More informationTechnical Information Condumax CLS21D/CLS21
TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application
More informationLevel sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H
Level measurement Level sensor Magnetostrictive, high-resolution measuring principle For sanitary applications, model FLM-H KSR data sheet FLM-H Applications Food and beverage industry Pharmaceutical industry
More informationLevel and Pressure. Product Information. Conductive level detection
Level and Pressure Product Information Conductive level detection Contents Contents 1 Product description 1.1 Application... 1. Function... 5 1. Types/Versions... 6 1.4 Application examples... 8 1.5 Adjustment...
More informationA Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >
A Higher Level of Performance Data Sheet Series 000 Pressure and Level Transmitters For more information, please visit > www.hawkmeasure.com Series 000 000-SAN Cable with separate electronics Description
More informationSoliphant T FTM20, FTM21
Technical Information Soliphant T FTM20, FTM21 Level limit switch Robust vibration limit switch for bulk solids, also for dust incendive hazardous areas Application Soliphant T is a robust level limit
More information