Locknuts. Cat. No. Bonding Locknuts 106 1/ /4 2-5/ TB 1-1/2 2-1/ TB 2-1/2

Size: px
Start display at page:

Download "Locknuts. Cat. No. Bonding Locknuts 106 1/ /4 2-5/ TB 1-1/2 2-1/ TB 2-1/2"

Transcription

1 T& Fittings Rigid and Intermediate Metal onduit Fittings Locknuts () Thickness Steel or malleable iron (steel thru 2 in.) or luminum 624 Many of the T& standard conduit and cable fittings are furnished with case hardened locknuts. This exclusive feature means the locknut tightens up against the box without deforming; the locknut bites into the box providing a positive ground; the fitting can be tightened from outside the box Stl. or M.I. lum. SST 39* /4 27/32 5/32 40* 3/8 5/6 5/32 4** 4L 4SST /2-7/64 5/32 42-T** 42L 42SST 3/4-3/8 3/ L 43SST -/6 3/ L 44SST -/4 2-5/32 3/ L 45SST -/2 2-/2 3/64 46-T 46L 46SST 2 3 7/ L 2-/2 3-9/6 3/ L 3 4-3/6 3/ L 3-/2 4-3/6 5/ L 4 5-5/6 5/32 5 5L 4-/2 5-5/6 7/ L 5 6 -/2 7/ L 6 7-3/4 7/32 * Hex shape ** ase hardened locknuts luminum locknuts comply with federal standard of copper-free aluminum; less than 0.4% copper For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Not UL or S certified onding Locknuts () Thickness Steel or malleable iron (steel thru 2 in.) Use anywhere an ordinary locknut is installed to ensure positive bonding of conduit to box and prevent loosening due to vibration. lso can be used for Service Entrance applications in conformance with ode. T& rigid conduit and EMT (thinwall) fittings comply with Federal Specification WF 408c. Screw 06 /2-3/ /4-5/ / x 7/6 09 -/4 2-5/ T -/2 2-/ T 2-/2 3-3/ T 3 4-3/ /4-20 x 5/8 4 3-/2 4-29/ T 4 5-7/ For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Steel finish: zinc plated Fittings Molded Santprene Seal / olour: lue Provides positive seal against water and oil. For use with rigid and intermediate metal conduits, or fittings to provide watertight or raintight seal at all enclosures. NPS threads.. 4SL /2.40 /8 /4 42SL 3/ /32 9/32 43SL.770 /64 9/32 44SL -/ /64 5/6 45SL -/ /64 9/32 46SL /6 9/64 Steel finish: zinc plated 9

2 T& Fittings Rigid and Intermediate Metal onduit Fittings Sealing Rings with Stainless Steel Retainer Sealing Ring-Santoprene Thermoplastic Rubber These sealing rings provide a liquid tight, dust tight, seal of fitting at enclosures onduit ±/ /2 -/64 3/ /4 -/2 5/ /4 -/ /4 2-9/64 -/ /2 2-27/64-3/ /64 2-5/ /2 3-7/6 2-43/ /64 3-9/ /32 4-9/64 NEM 3R, 4, 6 and 3 onding and Grounding Wedges Series 3650 Series 365 pplication To effectively bond terminating fitting or conduit to a box or enclosure Features Sizes 3/4 in. thru 6 in. equipped with an additional bonding screw to install bonding jumper where required an be added to an existing installation without disconnecting conductors Standard Material/Finish /2 in. size Steel/Electro-zinc Plated 3/4 in. thru 6 in. size ronze/tiplated Range /2 in. thru 6 in. conduit onformity UL 467.S No. 4 NFP (NSI) Federal Specification Especially suited for grounding old work, but equally convenient for new, grounding wedges provide grounding without a jumper except in concentric knockouts. When a jumper is required, it fits under a set screw in the grounding wedge. Update existing installations to meet code requirements for bonding (E Section 0-806) without disconnecting wiring. Use on new wiring also.. Loosen bushing and position wedge 2. Tighten bushing and bonding screw onding and Grounding Wedges 3650 / / / / / /

3 T& Fittings Rigid and Intermediate Metal onduit Fittings lackjack onduit Grounding ushings Mounting screw with nylon locking patch has a cone point to lock bushing securely in place Integral grounding lug enhances ground continuity. dded ground wire range taking reduces inventory. ccepts copper or aluminum ground wires Insulating nylon surface is 50 rated and covers top of bushing, including lug corners ngle of lug screw improves accessibility when securing grounding wire Innovative design makes installation quicker, easier. The lackjack Grounding ushing never has to be threaded onto a conduit. It is simply placed in position on either a threaded or non-threaded rigid or IM conduit, with the grounding lug in perfect position to accept the grounding wire. Even in tight installations, it s as simple as one, two, three. ompare the installation with conventional bushings that must be threaded onto the conduit. In tight areas, you may have to remove the grounding lug, keep up with the loose parts, and then reattach the lug. Then you still have to twist and turn the bushing to get the lug in position to accept the grounding wire. The lackjack bushing does away with these needless delays for good, making it the ideal grounding bushing and the only logical choice for small spaces, corners, and multiple conduit runs. nd, because the grounding lug is an integral part of the bushing, it is designed not to fall off or get lost. Innovative design improves performance The lackjack bushing provides superior ground continuity The design of the lackjack bushing has an integral, cast-on grounding lug for better ground continuity. This means that the lackjack bushing stands up to intense loads. Secure grip forms lasting bond The lackjack bushing s cone point mounting screw bites securely into both threaded and non-threaded rigid conduits. nd the lackjack bushing s nylon locking patch is designed to prevent the screw from loosening due to vibration. Reduce inventory ecause the lackjack Grounding ushing is designed for threaded and non-threaded conduits, and the ground lugs are designed to handle an extended range, the number of parts in inventory is reduced by up to two-thirds without losing any application coverage. Insulator surface features a rounded design to reduce drag and prevent abrasion during wire pulling ast threads opposite the mounting screw tighten the fit during installation lackjack onduit Grounding ushings Lug Screw: 4-4: Slotted 4-2/0: Slotted 6-4/0: Internal Hex Drive Standard Material/Finish ody: Malleable Iron or luminum Mounting Screw: (/2 in.-2 in.) Stainless Steel, (2-/2 in.-6 in.) rass Lug Screw: Stainless Steel Finish: Zinc Plated or Mechanical Galvanized Range onduit: /2 in. thru 6 in. threaded or threadless rigid/im Wire Range: #4 WG to 4/0 WG U/L onformity UL 54 & UL 467 S 22.2 No. 8.3 & S 22.2 No. 4

4 T& Fittings Rigid and Intermediate Metal onduit Fittings lackjack onduit Grounding ushings Zinc Plated Malleable Iron luminum onduit Size (in.) Ø Max. Ø Max. Dim. Ø Max. ØD Max. E Max. Wire Range G G /0 /2 G G G G /0 3/ G G G G /0 G G G G / /0 G G / / G G /0 G G /0 2-/2 G G /0 G G /0 3 G G /0 G G /0 3-/2 G G / G G /0 4 G G /0 G G /0 5 G G /0 G G /0 6 G G /0 Suggested Specifications Insulated grounding and bonding bushing (Series G050-G600) Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing Series G as manufactured by Thomas & etts. Grounding and bonding bushings used shall be approved for the purpose and (i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion. (ii) ushing insulator shall be listed or certified for 50 /302 F application with a flammability rating of 94V-O. Insulator must be positively locked in place. * Mechanical galvanization is available in the 3870 Series; add suffix MG to Nylon Insulator (50 ) Mounting Screw Lug Screw 4-4: Slotted 4-2/0: Slotted 6-4/0: Internal hex drive Ø E Ø Throat I.D. D For Threaded & Threadless Rigid & IM onduit 2

5 T& Fittings Rigid and Intermediate Metal onduit Fittings Threaded Insulated Grounding ushing pplication For quick installation of bonding jumper to multiple metal conduits (Rigid and IM) Designed to bush conductors and prevent insulation damage Features Ease of installation, lay in lug design ast malleable iron body designed to lock insulator in place within body, reducing common assembly problem resulting in dislodging of insulator Insulator rated for 50 /302 F application Standard Material / Finish ody: Electro-zinc plated Lay-in lug: luminum/tin-plated Insulator: Thermoplastic 50 /302 F pplication with 94V-0 flammability Insulator Set-Screw (one) Wire lamping Screw ushing asting Lay-In* Lug onduit ushing Dia. (in.) Throat Dia. (in.) Lug Lenght (in.) Swing Radius (in.) ushing Height (in.) Wire Range WG U/L 3870-T / /0 387-T / / / / / / / / / / / / / / / / / / / / / /0 Temperature rating 50 Meets oast Guard Regulation G293 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details *ontact your Regional Sales Office for copper lay in lug 3

6 T& Fittings Rigid and Intermediate Metal onduit Fittings Nylon insulated metallic bushings Steel or malleable iron (Steel thru -/2 in.) The anadian Electric ode (2) calls for protetion of ungrounded conductors by means of smoothly rounded insulating surfaces at the entrance to raceways, pull boxes, junction boxes, etc. T& insulated throat fittings, recognizable by the distinctive trademarked blue insulating liner in the throat, meet and surpass this ode requirement. In addition, T& insulated fittings also reduce wire pulling effort by as much as 50%. Temperature rating 05. Insulated Throat Fittings Steel or M.I. luminum L /2 -/32 29/ L 3/4-9/32 3/ L -9/32 9/ L -/4-5/6 2/ L -/2 2-3/6 23/ L 2 2-/6 7/ L 2-/2 3-3/6 3/ L /32 5/ L 3-/2 4-7/6 -/ L 4 4-7/8-3/ L 4-/2 5-7/6-5/ L 5 5-3/32-9/ L 6 7-3/6 -/32 Not S ertified The aluminum series are not S certified Metallic ushings luminum, steel or malleable iron (steel thru -/2 in.) Smoothly rounded shoulder covers end of conduit; broad flange covers knockout hole. High ribs make tightening easy with fingers or with wrench. /2 in.--/2 in. sizes, formed in steel, have extra smooth shoulders. Locknut-type base gives improved bonding and resists loosening under conditions of vibration. Steel or M.I. luminum 22 22L /2 -/32 3/ L* 3/4-9/32 3/ L -9/32 /2 25-T 25L -/4-5/6 9/ L -/2 2-3/6 9/ L 2 2-/6 9/ L 2-/2 3-3/6 3/ L /32 3/6 30-T 30L 3-/2 4-7/6 5/6 3-T 3L 4 4-7/8 32-T 4-/2 5-7/6-5/64 33-T 33L 5 6-/6 -/6 34-T 34L 6 7-3/6 -/6 * Not UL Listed or S ertified For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details ll Plastic Insulating ushings Impact-resistant plastic insulation. These bushings have ribs for gripping when installing. Perfect threads for easy thread on. UL Listed 05. NPT threaded. Plastic Insulating ushings 222-T /2 -/6 3/8 223-T 3/4-9/32 3/ /64 9/6 225-T -/4 2-/32 9/ /2 2-5/64 9/ /32 5/8 228-T 2-/2 3-3/32 3/4 229-T 3 4-3/32 3/4 230-T 3-/2 4-5/8 7/ /6 7/ /2 5-5/8 7/ / /6 Flame retardant. UL Rated 94V- 4

7 T& Fittings Rigid and Intermediate Metal onduit Fittings Insulating ushing for Threadless Rigid onduit and Intermediate Metal onduit TRI50 Series pplication When assembled to the end of a threadless conduit, provides a well rounded insulating surface over which conductors may be pulled or on which conductors may bear while in service Features Designed to be popped onto, and bush, conduit end Fast easy installation without screws High impact thermoplastic construction Standard Material High impact thermoplastic listed for 05 (22 F) application Flammability lassification 94V- Standard Finish s molded Range /2 in. through 4 in. conduit onformity UL 54 NSI 80.4 NFP (NSI). ut conduit end squarely. Remove sharp edges and burrs on inside and outside diameters by reaming or filing. 2. Slip the pop-on bushing over the end of the conduit. 3. Using the flat surface of any standard utility tool such as an electricians pliers (or a hammer with a block of wood, for the larger sizes), strike the bushing on its top surface using a Series of light blows until the end of the conduit rests against the bushing throat and conduit stop. Insulated Metallic ushing TRI-50 /2 9/32-9/32 -/6 TRI-75 3/4 25/32-25/64 -/4 TRI-00 -/2-9/6 TRI-25 -/4-5/6-5/8-59/64 TRI-50 -/2-7/32-2/32 2-/64 TRI /32-3/6 2-/6 TRI /2 2-23/ /4 TRI /64 2-7/ /32 TRI /2 3-3/8 2-5/6 4-29/64 TRI /32 2-3/32 5 I.M.. sizes /2 in. thru 4 in. UL Rated flame retardant 94V- 5

8 T& Fittings Rigid and Intermediate Metal onduit Fittings 320 Series pplication To bush knockout openings in metal boxes or enclosures Features One piece construction designed to snap in place High impact strength self-extinguishing, non-dripping (per UL 94) thermoplastic construction Standard Material Thermoplastic rated for 05 (22 F) application Standard Finish s molded Range in. through in. nominal diameter knockout opening (/2 in. through 2 in. trade size knockouts) HWall thickness of box or enclosure in. max. up to in. trade size in. max. -/4 in. through 2 in. trade size onformity UL 54 S 22.2 No. 8.3 NFP (NSI) Knockout ushings D One-piece knockout bushing quickly snaps into outlet box, switch box, or other enclosure left vacant by wiring modifications or maintenance changes. Provides smooth, rounded insulation surface for easy wire pulling. Easily installed by hand, they are available to fit /2 in. through 2 in. knockouts. UL Listed 05. High impact thermoplastic. Trade For use in KO* +.032/-0.6 (in.) (in.) (in.) 320 / / / / * Per UL and NEM standards Material: Thermoplastic Flammability classification of 94V- Per UL 94 Service temperature: -40 to 05 Wall Thickness of Elec. ox (in.) (in.) D (in.) MX MX INSULINER Sleeves Slip over wires insert into bushing snaps into place High dielectric nylon, 05. n Insuliner sleeve snapped into a regular bushing makes a S Listed insulated bushing. For standard rigid conduit, EMT (thinwall conduit) or any standard bushed outlet. Especially suitable for use with flexible metallic conduit. onverts ordinary bushing to code approved insulated bushing without disturbing wiring. 422 /2 5/ /4 / / / T -/2 427-T 2 -/ T 2-/2 -/ /2 430-T 3-/2-25/ / / /2 Oxygen index >28 6

9 T& Fittings Rigid and Intermediate Metal onduit Fittings Knockout Plugs pplication To bush knockout openings in metal boxes or enclosures Features One piece construction designed to snap in place High impact strength self extinguishing non-dripping (per UL 94) thermoplastic construction Standard Material Thermoplastic rated for 05 (22ºF) application Standard Finish s molded Range in. through in. nominal diameter knockout opening (/2 in. through 2 in. trade size knockouts) Wall thickness of box or enclosure in. max. up to in. trade size 0.40 in. max. -/4 in. through 2 in. trade size onformity UL 54 S 22.2 No. 8.3 NFP (NSI) 05 rated by UL Made from flame retardant, non-dripping thermoplastic. Knockout Trade 45 / / / / Wall thickness of electrical box max. Meets oast Guard Regulation 293 Pennies Steel penny under a bushing will seal the end of the conduit during construction. Made to fit any bushing. ompletely salvageable. 85-T /2 86 3/ /4 89 -/ / T 3-/ UL not applicable 7

10 T& Fittings Rigid and Intermediate Metal onduit Fittings Plug, onduit, onnectors (Push-Penny Plugs) pplication To plug open end of conduit or fitting in order to prevent ingress of trash, dirt or moisture during construction and remodeling Features Wide range of application; can be used with rigid metal conduit, intermediate metal conduit, electrical metallic tubing, all connectors and all bushings Designed to stand up to normal handling and is functionally unaffected by moisture Standard Material Polyethylene Standard Finish s molded onformity S 22.2 No. 8 NSI 80.4 NFP (NSI) NEM F- E Rule: Unused openings in boxes, cabinets and fittings shall be effectively closed by plugs or plates affording protection substantially equivalent to that of the wall of the box, cabinet or fittings. ushings and Push-Penny Plugs (in.) ssembly consist of ushing Push-Penny 460 /2 -/ T 46 3/4-9/ / /4-5/ /2 2-3/ * 2 2-2/ * Maleable Iron vailable in luminum dd suffix L to Push-Penny Plugs 470-T /2 47 3/ / / * 2-/2 477* 3 478* 3-/2 479* 4 *Not S ertified UL not applicable 8

11 T& Fittings Rigid and Intermediate Metal onduit Fittings pplication To effectively bush factory or field-punched, cut, or drilled holes in metal boxes or enclosures To couple boxes back-to-back Features Rugged construction Insulator curled over to: ush conductors entering/leaving at any angle. Reduce wire pull effort. Protect threads against damage in handling Standard Material 942 Series ody /2in.-Steel 3/8 in., 3/4 in. through 6 in. - Malleable Iron Insulator Nylon 842L Series ll opper-free luminum (less than 0.4% copper) 942 Series Electro-zinc Plated & hromate oated 842L Series Degreased Range 942 & 842L Series /2 in. through 6 in. ll hub threads straight pipe (NPS) onformity UL 54 S 22.2 No. 8.3 Federal Specification W-F-408 NSI 80.4 NFP (NSI) NEM F- Federal Standard H-28 (Threads) 942 Series 842L Series (Non Insulated) NPS Threads Standard Finish Steel, malleable iron or aluminum HSE Nipples Stl. or M.I. lum. 84T 3/8 3/6 7/6 842T 842LT /2 5/6 /32 843T 843LT 3/4-3/6 / L -7/6 2/ L -/4-3/4 3/ L -/2 2-/6 3/ L 2 2-/2 3/ L 2-/2 3-/6 -/ L 3 3-3/6-3/ L 3-/2 4-3/8-5/ L 4 4-3/4-5/ L 5 5-7/8-5/ L 6 6-5/6-3/8 Not UL Listed For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Steel or malleable iron HSE Nipples Nylon Insulated 942 /2 5/6 /2 9/ /4-3/6 7/32 23/ /6 2/32 7/ /4-3/4 25/32 -/ /2 2-/6 3/6-3/ /6 3/32 -/ /2 3-/6 -/6-7/ /6-3/6-9/ /2 4-3/8-5/6-25/ /8-5/6-3/ /32-5/6-3/ /6-3/8-7/8 9

12 T& Fittings Rigid and Intermediate Metal onduit Fittings Threaded Hubs (ullet Hubs) for Threaded Rigid Metal onduit/im/pv oated Rigid Metal onduit () () (E) () () (E) 370 Series 370L Series 485 Series Predetermined ompression (D) () (G) () (D) (F) (G) pplication To connect threaded metal conduit (ferrous rigid/nonferrous rigid/pv coated/ or intermediate metal) to a threadless opening in a box or enclosure in outdoor or indoor location exposed to continuous or intermittent moisture To positively bond conduit to box or enclosure Features Rugged steel/malleable iron/copper-free aluminum construction. Tapered internal threads for watertight/ dust tight union () Threads relieved to prevent bottoming of conduit ensuring sound assembly () Recessed sealing ring at box end. aptive sealing ring () Hardened steel/malleable iron/copper-free aluminum locknuts designed to provide high quality ground continuity; extended reach of locknut permits clamping on thin boxes and enclosures (D) Insulated throat protects conductors, prevents abrasion and thinning of conductor insulation, reduces wire pull effort (E) Suitable for hazardous location use per following: () lass II, Division Groups E, F, G, E Rule lass II, Division 2 Groups E, F, G, E Rule lass III, Division Rule lass III, Division 2 Rule PV coated 485 Series () Protects fitting from extremely corrosive surroundings without affecting integrity of electrical grounding path (F) (2) Provided with overlapping sleeve for additional seal (G) anadian Electric ode Rule states that, Where dissimilar metals cannot be avoided at bonding connections as indicated in Rule 2-2 (2). onnections shall be made using methods or material that will minimize deterioration from galvanic action. Joint Industrial ouncil (JI) Electrical Standards also forbid dissimilar metals in contact for the same reason and require that the fittings for metal conduit be of malleable iron or ductile iron and have impact strength comparable to that of the conduit. opper-free luminum opper-free aluminum castings for fittings have a maximum of 0.4% copper. The most detrimental effect of higher percentage of copper on aluminum base alloy is its decrease in corrosion resistance. 20

13 T& Fittings Rigid and Intermediate Metal onduit Fittings Threaded Hubs (ullet Hubs) for Threaded Rigid Metal onduit/im/pv oated Rigid Metal onduit (cont d) Standard Material ody Locknut Screws O Ring Insulator oating Series 370L Series /2 in. thru in. Steel ll opper-free luminum -/4 in. thru 6 in. Malleable Iron /2 in. thru 2 in. Steel (hardened) /2 in. thru 2 in. Steel (hardened) 2-/2 in. thru 6 in. Malleable Iron 2-/2 in. thru 4 in. opper-free luminum Steel (hardened) una N Nylon PV Standard Finish 370 Series 370L Series 485 Series PV Outside Electro-zinc Hub Electro-zinc Plated s ast hromate oated Locknuts ll Ferrous locknuts Electro-Zinc Plated and hromate oated Screws ll Electro-Zinc Plated & hromate oated Plated hromate oated-inside Range 370 Series /2 in. thru 6 in. onduit 370L & 485 Series /2 in. thru 4 in. onduit ll hub threads straight pipe ll female threads taper pipe (NPT) onformity UL 54 S 22.2 No. 8.3 NSI 80.4 NFP (NSI) NEM F- JI EGP; JI EMP Federal Specification W-F-408 Federal Standard H-28 (Threads) 2

14 T& Fittings Rigid and Intermediate Metal onduit Fittings Steel/Malleable Iron and luminum Hub Fittings Nylon insulated luminum, steel, or malleable iron (steel through in.). With Neoprene O Ring provides a watertight threaded hub on enclosures. UL Listed 05. Stl. or M.I. lum.** L /2-3/8-5/6 3/ L 3/4-5/8-3/8 7/ L 2-3/32-23/32-7/ L -/4 2-9/6 2 -/ L -/2 3-3/32 2 -/ L 2 3-5/8-3/32 -/ /2 4-/8 2-2/32-5/ / /2 5-9/6 3-/8 2-/8 379-T 4 6-9/6 3-/8 2-/8 38-T /6 382-T 6 9-3/ /6 ** luminum not available with insulated throat UL Listed raintight and S ertified watertight and dust tight For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Wall Thk. Max. (in.) 5/6 /2 ullet Hub Fittings with onding Locknut Nylon Insulated Description 40 / /4 403-T vailable in steel or malleable iron /2 Supplied with 06 Series bonding nut Temperature rating: /2 40-T 4 S certified watertight and dust tight 22

15 T& Fittings Rigid and Intermediate Metal onduit Fittings PV oated Hub for Rigid onduit Steel or malleable iron (steel thru -/4 in.) Locknut NFS Thread PV Plastic oating 485 /2-2/64 2-/8-7/ /4-9/32 2-3/8 2-/ /32 2-3/4 2-3/ /4 2-5/32 3-3/8 3-/ /2 2-29/32 3-5/8 3-/ /8 3-3/ /2 3-27/ / /32 4-5/8 5-3/ /2 5-9/64 4-3/6 5-7/ /4 4-9/6 6-7/6 *485 Series are S ertified Watertight and Dustight for Ordinary Locations Insulator Sealing ring Spacing hart for ullet Hubs enter to enter Spacing onduit Sizes (in.) /2 3/4 -/4 -/2 2 2-/2 3 3-/2 4 Min. Space from enter of ullet Hub to Wall of ox (in.) /2-7/6-5/8-3/4 2-/8 2-3/8 2-5/8 2-7/8 3-5/6 3-/2 3-7/8 3/4 7/8 3/4-3/4-7/8 2-/4 2-/2 2-3/4 3 3-/2 3-3/4 4-/8 7/8 -/ /8 2-5/8 2-7/8 3-/8 3-5/8 3-7/8 4-/4 -/8-3/8 -/4 2-/6 2-5/6 3-/4 3-/2 4 4-/4 4-/2-3/8-3/4 -/2 3-/8 3-/2 3-3/4 4-/8 4-3/8 4-3/4-5/ /4 4 4-/2 4-3/4 5-7/8 2-/2 2-/2 4-/4 4-3/ /8 2-/ /8 5-3/8 5-3/4 2-5/8 3-5/8 3-/2 5-5/ /8 4-/8 4 6-/4 3-/4 4-5/8 KO Diameter Min. (in.) T& Hub enterline Spacing hart onduit Trade Size /2 (in.) 3/4 (in.) (in.) -/4 (in.) -/2 (in.) 2 (in.) 2-/2 (in.) 3 (in.) 3-/2 (in.) 4 (in.) 5 (in.) 6 (in.) (in.) /2-9/6 3/4-43/64-25/32-27/32-6/64 2-/8 -/4 2-/32 2-9/64 2-5/6 2-/2 -/2 2-7/32 2-2/64 2-/2 2-/6 2-7/ / /64 2-3/4 2-5/6 3-/8 3-3/8 2-/2 2-23/ / /6 3-3/8 3-5/8 3-7/8 3 3-/32 3-9/64 3-5/6 3-/2 3-/6 3-5/6 4-3/6 4-/2 3-/2 3-/32 3-2/64 3-5/8 3-3/6 4 4-/4 4-/2 4-3/6 5-/ /32 3} 3-7/8 4-/6 4-/4 4-/2 4-3/4 5-/6 5-3/8 5-5/ / /64 4-9/6 4-3/4 4-5/6 5-3/6 5-7/6 5-3/4 6-/6 6-5/ /6 4-5/64 4-3/32 5-5/32 5-/32 5-9/ /32 6-5/32 6-5/ /32 7-3/32 7-3/6 Nearest obstruction to center of hub 27/32 6/64 -/8-5/6 -/2-3/ /6 2-5/8 2-7/8 2-9/6 3-3/32 23

16 T& Fittings Rigid and Intermediate Metal onduit Fittings The T& Hub Never before has a single hub fit like this one. Designed for unequalled performance. The innovative engineering of the T& Hub will, quite simply, raise your performance expectations for threaded hubs. The revolution in hub design is here, and the fate of our competition is sealed. 30º 2 6. Sealing ring and groove with innovative profile outperforms standard O ring design. Sealing ring is captive before installation and resists buckling or slipping during installation. The seal groove is designed for op ti mum compression of the sealing ring. The sealing ring is designed to provide a complete 360 seal, even when the conduit is not perpendicular with the enclosure. (See Figure ) Figure Figure 2 Figure 3 2. Locknut design with pe riph er al slots and a hexagonal/angled spline spaced every 30 enables easy application of torque with wrench or hammer and screw driv er. (See Figures 2 & 3) 3. Sharper and deeper teeth on locknut and body designed for a more penetrating bite for improved bonding to the enclosure. 4. Hexagonal / splined body design for fast, easy installation with wrench or hammer and screwdriver. 5. Precision machined tapered threads designed to create watertight union. 6. Insulated throat molded from 05 rated thermoplastic with a flammability rating of 94V-O. T& Hub D Throat Dia. E Zinc luminum Trade Size (in.) Dia. (in.) Max. Panel Thickness D (in.) Throat Dia. E (in.) H050-T H050 /2-7/6-9/6 7/8 9/32 3/6 H075-T H075 3/4-2/32-9/32 29/32 25/32 H00-T H00 2-3/6 -/6 H25-T H25 -/4 2-3/8-7/8 -/6-5/6 H50-T H50 -/2 2-3/4-7/8 -/6-7/32 H200-T H /4-5/6-5/32-3/32 H250-T H250 2-/2 3-3/4 2-9/6-9/6 2-3/32 /4 H300-T H /8 2-2/32-9/32 2-3/32 H350-T H350 3-/ /32-5/8 3-3/32 H400-T H /2 2-23/32-5/8 3-7/8 H500-T H /8 3-/32-5/6 4-5/6 H600-T H /6 3-5/ Material Hub and Locknut: zinc or copper free aluminum Insulating Throat: thermoplastic temp. rating 05, Flammability Rating: 94V-0 Sealing Ring Nitrile (UN N ) For hrome Plated Hubs add suffix P (i.e. H050P). Meets NEM sealing requirements for NEM 3R, 4 & 3 enclosures. U.L. Listed and S ertified. S ertified use in hazardous locations lass I, Division 2, lass II, Groups E, F and G, lass III, Division, 2 and Type 4. hrome Plated Hubs (suffix- P ) are rated NEM 4X. For luminum Hubs add suffix (i.e. H050). 24

17 T& Fittings Rigid and Intermediate Metal onduit Fittings T& Grounding Hub Zinc luminum Trade Size (in.) Dia. (in.) D Max. Panel Thickness E Throat Dia. D Throat Dia. E H050GR- H050GR- /2 7/6 9/6 7/8 3/6 9/32 H075GR- H075GR- 3/4 2-/32-9/32 29/32 3/6 25/32 H00GR- H00GR- 2-3/6 -/6 /4 H25GR- H25GR- -/4 2-3/8-7/8 -/6 /4-5/6 H50GR- H50GR- -/2 2-3/4-7/8 -/6 /4-7/32 H200GR- H200GR- 2 3-/4-5/6-5/32 /4-3/32 H250GR- H250GR- 2-/2 3-3/4 2-9/6-9/6 /4 2-3/32 H300GR- H300GR /8 2-2/32-9/32 /4 2-3/32 H350GR- H350GR- 3-/ /32-5/8 /4 3-3/32 H400GR- H400GR- 4 5-/2 2-23/32-5/8 /4 3-7/8 H500GR- H500GR /8 3-/32-5/6 /4 4-5/6 H600GR- H600GR- 6 7-/6 3-5/32 2 5/6 6 Material Hub and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 05 ; flammability rating: 94V-0 Sealing Ring: Nitrile (UN N ) For hrome Plated Hubs add suffix P (i.e. H050GRP) For 36 Stainless Steel Hubs add suffix SST (i.e. H050GRSST) For PV coating add suffix PV (i.e. H050GRPV-) Meets NEM sealing requirements for NEM 3R, 4 & 3 enclosures UL Listed and S ertified S approved for use in hazardous locations: lass I, Division 2, lass II, Divisions & 2, Groups E, F & G, lass III, Division, 2 and Type 4. T& Grounding and onding Locknut with Lay-In Lug without Lay-In Lug Trade Size (in.) Dia. (in.) Height (in.) Ground Screw (in.) Max. onductor Size Grounding Locknut for Hubs L050GRL L050GR- /2 -/2 3/32 #0-32 x /4 #0 L075GRL L075GR- 3/4 -/6 3/32 #0-32 x /4 #0 L00GRL L00GR- 2 3/32 #0-32 x /4 #0 L25GRL L25GR- -/4 2-3/8 5/32 /4-20 x /4 #0 L50GRL L50GR- -/2 2-3/4 5/32 /4-20 x 5/6 #8 L200GRL L200GR- 2 3-/4 5/32 /4-20 x 5/6 #8 L250GRL L250GR- 2-/2 3-3/4 /6 /4-20 x 5/6 #6 L300GRL L300GR /8 23/32 /4-20 x 5/6 #6 L350GRL L350GR- 3-/2 5 23/32 /4-20 x 5/6 #6 L400GRL L400GR- 4 5-/2 23/32 /4-20 x 5/6 #4 Material Locknut: zinc or copper-free aluminum For luminum Locknuts add suffix. (i.e. L050GR-) For hrome Plated Locknuts add suffix P. (i.e. L050GR-P) For 36 Stainless Steel Locknuts add suffix SST (i.e. L050GRSST). 25

18 T& Fittings Rigid and Intermediate Metal onduit Fittings T& ulkhead Fittings cross Flats Thread TYPE 4 Diameter ulkhead Fitting Zinc luminum Trade H050HD H050HD /2 H075HD H075HD 3/4 H00HD H00HD H25HD H25HD -/4 H50HD H50HD -/2 H200HD H200HD 2 H250HD H250HD 2-/2 H300HD H300HD 3 H350HD H350HD 3-/2 H400HD H400HD 4 H500HD H500HD 5 H600HD H600HD 6 Height Nipple Nut Not Included Thru ulkhead Fitting Zinc luminum H050TF H050TF /2 H075TF H075TF 3/4 H00TF H00TF H25TF H25TF -/4 H50TF H50TF -/2 H200TF H200TF 2 NPT THRED Nipple Nut Not Included Thru ulkhead Hub Zinc luminum H050TH H050TH /2 H075TH H075TH 3/4 H00TH H00TH H25TH H25TH -/4 H50TH H50TH -/2 H200TH H200TH 2 NPSL THRED Trade Thread (in.) Height (in.) Diameter (in.) cross Flats (in.) (in.) (in.) /2 /2-4 -3/32-7/6 3/4 /2 3/4 3/4-4 -5/32 -/6 -/4 25/32 7/32 --/2 -/6 2-7/32 29/32 9/32 /4 -/4--/2-25/32 2-3/8-27/32 29/32 2/32 -/2 -/2--/2-3/6 2-3/4 -/8 29/32 2/ /2-27/32 3-/4 2-5/8 5/6 2/32 2-/2 2-/2-8 29/32 3-3/4 3-/8 7/32 7/ /6 4-3/8 3-25/32 5/6 29/32 3-/2 3-/ / /32-3/8 7/ /6 5-/2 4-27/32-3/8 7/ /32 6-5/8 5-29/32-5/32 7/ /6 7-/32 -/2 3/32 Material Hub, ody and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 05 ; Flammability rating: 94V-0 Sealing Ring: Nitrile (UN N ) For hrome Plated ulkhead add suffix P 26

19 T& Fittings Rigid and Intermediate Metal onduit Fittings T& XD Expansion/Deflection oupling for Rigid onduit Watertight, flexible connections support movement and thermal expansion Use the XD Expansion/Deflection oupling to join two conduit runs in applications where movement in any direction is required. The coupling provides a flexible, watertight connection, accommodating axial or parallel movement of up to 3/4 in. and angular movement of up to 30 from normal position. While similar fittings exist on the market today, this new and enhanced XD Expansion/Deflection oupling ships complete with an Erickson conduit union to significantly reduce installation time and effort and includes a stainless steel inner sleeve for extreme durability, protection and easier wire pulling. The hubs are zinc-plated and then coated with aluminum acrylic paint for dual-layer corrosion protection. In addition, the copper ground mounting plates and internal grounding bonding jumper are entirely enclosed inside the coupling for added security against vandalism and theft. ccommodates axial expansion/contraction up to 3/4 in., parallel deflection up to 3/4 in. and angular misalignment up to 30 Suitable for use indoors, outdoors, direct buried or embedded in concrete Watertight, flexible neoprene outer jacket, zinc-plated and acrylic-painted hubs and stainless steel tamper-proof straps ensure superior corrosion resistance ideal for use in harsh environments opper ground mounting plates and internal grounding bonding jumper both entirely enclosed to safeguard against theft Includes an Erickson conduit union for faster, easier installation to reduce labor costs Durable stainless steel inner sleeve provides a constant, smooth inner diameter in any position to ease wire pulling and protect wire insulation from damage NPT threaded hubs fit standard threaded rigid metal conduit an also be used with rigid PV conduit with the use of standard adapters (not supplied) Hub Size (in.) D XD3-T 9-3/6 8-5/32 6-7/6 3-/32 XD4-T -/4 9-3/6 8-3/8 6-7/8 3-7/8 XD5-T -/2 9-/4 8-7/32 6-3/4 4-5/32 XD6-T 2 9-3/4 8-2/32 7-/4 4-/6 XD7-T 2-/2-3/4-3/8 8-/2 4-7/8 XD8-T 3 0-/2 9-2/32 7-2/32 5-5/6 XD9-T 3-/2 0-9/6 9-3/4 7-3/4 6-5/8 XD00-T 4 3-3/6-27/32 8-7/8 7-9/32 XD02-T /6 8-9/32 XD04-T 6 4-5/6 3-3/8-3/8 9-9/32 D Relaxed Position Up to 3/4 in. Up to 3/4 in. Expansion From ontraction From Relaxed Position Relaxed Position Standard Material/Finish Hub... Ductile cast iron, zinc-plated and aluminum acrylic painted Inner Sleeve... Sainless Steel Internal Grounding onding Jumper..... Flexible copper braid Ground Mounting Plates... opper Hub Rings... Zinc-plated steel Outer Jacket... Molded neoprene (natural black) Jacket Straps... Stainless Steel Erickson conduit union Ground mounting plates Watertight, flexible neoprene outer jacket Tamperproof stainless steel jacket straps 30º Up to 30 ngular Deflection Internal flexible copper braid grounding bonding jumper ertifications/ompliances S ertified to 22.2 and UL Listed to UL 54 No. 8 Suitable for Wet Locations (hub sizes in. 2-/2 in.) Watertight NE rticle compliant Up to 3/4 in. Parallel Deflection Stainless steel inner sleeve Hex gland nut Ground mounting plates 27

20 T& Fittings Rigid and Intermediate Metal onduit Fittings 4" Movement Shown T& XJG onduit Expansion ouplings for Rigid onduit Internal onding Jumper Gland Nut Easy to Install Save Time and Money on the Job No Disassembly Required! 8" Movement Shown Stationary onduit (not supplied) Internal Sliding ushing (Keyed) Standard Material/Finish ody... Malleable or Ductile Iron, available PV oated Internal onding Jumper..... opper raid Exterior and Interior Finish... Zinc plating, aluminum acrylic paint Packing... PTFE/Synthetic fiber Material (Teflon oated) Teflon is a trademark of DuPont. Teflon Packing Ring (E.I. DuPont Trademark) onding ushing S Moving onduit (not supplied) Suggested Specifications for expansion fittings for rigid steel or Intermediate Metal onduit Used where: Raceways require expansion fittings to compensate for thermal expansion and contraction. Expansion fittings and telescoping sections of metal raceway must be made electrically continuous by bonding jumpers or other means Fitting will be constructed from cast iron with exterior and interior zinc plating for corrosion protection The fitting shall be constructed so that disassembly is not required during installation Fitting shall be raintight after installation The fitting shall have an internal bonding jumper constructed of a copper braid, sized to meet UL fault current test requirements and comply with bonding requirements E article 0-62 and 0-64 External bonding jumper shall not be required to comply with E requirements ccepted Manufacturer: Thomas & etts XJG-T Series 2 With a wrench, tighten the gland nut to compress the Teflon packing, creating a raintight seal around the conduit. Slide the fitting onto the conduit until it stops at the internal sliding bushing. Tighten and you re ready. No parts to reassemble! 3 Thread the next length of conduit into the other end of the fitting and tighten. You re done! Movement (in.) XJG24-T XJG28-T XJG34-T XJG38-T XJG44-T XJG48-T XJG54-T XJG58-T XJG64-T XJG68-T XJG74-T XJG78-T XJG84-T XJG88-T XJG94-T XJG98-T XJG04-T XJG08-T XJG208-T lso available in PV Ocal coating and for EMT. 28

21 T& Fittings Rigid and Intermediate Metal onduit Fittings T& XJG-EMT onduit Expansion ouplings for EMT Features Fast and easy installation no disassembly required No external grounding strap needed internal bonding jumper is protected from tampering and the environment Standard Material/Finish ody... Malleable or ductile iron Internal onding Jumper..... Tinned copper braid Exterior and Interior Finish... Zinc plating, aluminum acrylic paint Packing... PTFE/Synthetic fiber material ertifications/ompliances S ertified to 22.2 and UL Listed to UL 54 No. 8 Suitable for Wet Locations (hub sizes in. 2-/2 in.) NE rticle compliant Note: XJG-EMT couplings are not raintight and are for use in dry locations only. They are UL Listed for use with aluminum EMT. Movement (in.) (length in.) (height in.) XJG24-EMT XJG28-EMT XJG34-EMT XJG38-EMT XJG44-EMT XJG48-EMT XJG54-EMT XJG58-EMT XJG64-EMT XJG68-EMT XJG74-EMT XJG78-EMT XJG84-EMT XJG88-EMT XJG94-EMT XJG98-EMT XJG04-EMT XJG08-EMT

22 T& Fittings Rigid and Intermediate Metal onduit Fittings Offset Reducers Zinc luminum Dia. (0) Trade Height (in.) Diameter (in.) D E H50-075ORGR-T H50-075ORGR-T -/2-3/4-2/32 2-3/4 5/6 23/32-29/32-9/32 /32 H50-00ORGR-T H50-00ORGR-T -/2- -25/32 2-3/4 -/6 23/32-29/32-9/6 7/32 H50-25ORGR-T H50-25ORGR-T -/2--/4-25/32 2-3/4 -/6 23/32-29/32-7/8 /32 H ORGR-T H ORGR-T 2-/2-2 2-/8 3-3/4-3/6 5/6 2-29/32 2-2/32 3/32 Material Offset Reducer and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 05 ; Flammability rating 94V-0 Sealing Ring: Nitrile (UN N ) For hrome Plated Offset Reducer add suffix P. (i.e. H50-25ORGRP-T) TYPE 4 Height D Dia. (Ø) E apoffs Height Zinc luminum Trade Size (in.) Height (in.) Diameter (in.) H050P H050P /2-3/32-7/6 9/32 27/32 3/6 H075P H075P 3/4-5/32 -/6 9/32 -/6 3/6 H00P H00P -/6 2 /6-5/6 /4 H25P H25P -/4-25/32 2-3/8 23/32-2/32 /4 H50P H50P -/2-3/6 2-3/4 23/32-29/32 /4 H200P H200P 2-27/32 3-/4 23/32 2-3/8 /4 H250P H250P 2-/2 2-9/32 3-3/4 7/8 2-29/32 /4 H300P H300P 3 2-9/6 4-3/8 7/8 3-/32 /32 H350P H350P 3-/2 2-9/6 5 29/32 4-/32 /32 H400P H400P 4 2-9/6 5-/2 29/32 4-/2 /32 H500P H500P /32 6-5/8 29/32 5-9/6 /32 H600P H600P /8 3/32 6-5/8 /32 Material apoff and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating 05 ; flammability rating 94V-0 Sealing Ring: Nitrile (UN N ) For hrome Plated apoff add suffix P. (i.e. H050PP) TYPE 4 apoff Dia. 30

23 T& Fittings Rigid and Intermediate Metal onduit Fittings Threadless Fittings/ouplings for Threadless Rigid Metal onduit and Intermediate Metal onduit pplication To connect and effectively bond threadless rigid metal conduit/intermediate metal conduit to a box or enclosure, or to couple ends of threadless conduit Features Steel/Malleable Iron onstruction ase hardened ring bites into conduit for high quality continuity and grip Nylon insulator firmly secured in place protects conductors and reduces wire pulling effort by as much as 50%; prevents thread damage in handling ase hardened steel locknut or malleable iron locknut designed to provide a positive bond Suitable for concrete tight application Raintight application apable of carrying ground fault currents up to 0,000 amps RMS (/2 in. through -/2 in. size) and 20,000 amps RMS (2 in. and above sizes) duration of current 3 cycles Standard Material Nut, Gland ody Ring Insulator Locknut /2 in. to in. Steel -/4 in. to 4 in. Malleable Iron ll Malleable Iron Steel (case hardened) Nylon /2 in. thru 2 in. Steel (hardened) 2 in. thru 4 in. Malleable Iron Standard Finish Electro Zinc Plated & hromate oated Range 823 & 820 Series /2 in. through 4 in. Size onduit 830 Series /2 in. and 3/4 in. Size onduit ll hub threads Straight Pipe (NPS) onformity UL 54 S 22.2 No. 8.3 NSI 80.4 NFP (NSI) NEM F- Federal Specification W-F-408 Federal Standard H-28 (Threads) 823 Series 830 Series 820 Series 3

24 T& Fittings Rigid and Intermediate Metal onduit Fittings Nylon Insulated Threadless Fittings split steel ring with diagonal serrations grips the conduit and bites into it for positive ground. Makes a permanent connection and eliminates the need for cutting a thread on the conduit. Insulation helps to guarantee continuity of service with protection of the conductor at the critical point the fitting bushing. onduit Size Nylon Insul. Non-Insul. (in.) /2 -/32-5/6 3/ /4-5/8 2 3/ /8 2-7/6 7/ /4 2-3/8 2-9/6 / /2 2-5/8 2-3/4 3/ /4 2-5/6 27/ T /2 3-5/6 3-5/6 -/ T /6 4-/8-7/ /2 5-3/6 4-/4 -/ /6 5 -/8 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Malleable iron construction. Threadless ouplings Eliminate conduit threading. When tightened with a wrench they make a UL Listed and S ertified concrete-tight connection Malleable iron construction. 820 /2-9/ /4-9/32 2-5/ /8 2-/ /4 2-3/8 2-3/ /2 2-5/8 3-5/ /4 3-3/ /2 3-5/6 5-3/ /6 5-/ /2 5-3/6 5-/ /6 5-/2 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Threadless Short Elbows Nylon Insulated 830 /2 -/32 -/2 /2 83 3/4-5/8-3/4 9/ /8-5/6 / /2 2-23/32 3-/8 3/6 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Ideal for entering enclosure or conduit body at right angles. Eliminates need to thread conduit. s with straight couplings, this fitting makes a concrete-tight connection. Malleable iron construction. 32

25 T& Fittings Rigid and Intermediate Metal onduit Fittings Specifications Set-Screw Fitting/oupling for Threadless Rigid Metal onduit and Intermediate Metal onduit 825 Series 824 Series pplication To connect and effectively bond threadless rigid metal conduit or intermediate metal conduit to a box or enclosure or to couple ends of threadless conduit Features Thickwall steel or malleable iron body Hardened hex head cup point screw to provide high quality bond aptive screw, will not vibrate loose Nylon insulated throat meets and exceeds all codes requirements for bushing: () Prevents thinning of insulation (2) Reduces installation effort (3) Prevents first thread damage oupling provided with positive center stop Suitable for concrete-tight application apable of carrying ground fault currents up to 0,000 amps RMS (/2 through -/2 in. size) and 20,000 amps RMS (2 in. and above sizes) Standard Material ody /2 in. thru 2 in. Steel 2-/2 in. thru 4 in. Malleable Iron Locknut /2 in. thru 2 in. Steel (hardened) 2-/2 in. thru 4 in. Malleable Iron Screw Steel (hardened) Insulator Nylon Standard Finish Electro Zinc Plated & hromate oated onformity UL 54 S 22.2 No. 8.3 NSI 80.4 NFP (NSI) NEM F- Federal Specification W-F-408 Federal Standard H-28 (Threads) 33

26 T& Fittings Rigid and Intermediate Metal onduit Fittings Insulated Set-Screw Fitting onduit 825 /2-3/8 3/ /4 -/2 7/ /6 35/ /4 2 5/ T -/2 2-5/6 5/ /6 / T 2-/2 3-3/ / /2 3-7/8 -/ /6 -/8 Sizes /2 in.-2 in. made of steel. Sizes 2-/2 in.-4 in. are malleable iron For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Eliminate conduit threading with these set screw fittings. aptive hex head screws tighten down onto conduit for positive holding strength and ground. The fittings are furnished with insulated throats reducing wire pulling effort by as much as 50%. pproved concrete-tight. Set Screw oupling onduit 824 /2 2-/ /4 2-/ T 2-27/ / /2 3-3/ / T 2-/2 3-7/ T 3 4-/ /8 Sizes /2 in.-2 in. made of steel; sizes 2-/2 in.-4 in. are malleable iron For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details. Eliminate the need for threading conduit ends when joining rigid conduit with these set screw couplings. aptive hex head screws provide positive holding strength and ground continuity. pproved concrete-tight. 34

27 T& Fittings Rigid and Intermediate Metal onduit Fittings ushed Elbows 460T /2-3/6 -/8 5/8 46T 3/4 2-/4 -/2 9/ /32-23/32 / /4 3-/8 2-/6 25/32 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details The noninsulated elbow has smoothly rounded shoulders to protect conductor insulation Malleable iron Short Elbows Nylon Insulated 4290 /2-7/32 -/4 / /4-7/6-5/6 9/ /32-9/6 / /4 2-7/32 2-/6 3/ /2 2-5/32 2-3/6 3/6 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details Not UL Listed The integral insulation of the insulated elbow is a guarantee that the bushing of every fitting will be smooth Malleable iron When an insulated elbow is not desired, the non-insulated short elbow should be used Malleable iron Short Elbows 4250 /2-5/6 -/4 7/ /4-7/32-5/6 / /6-9/6 5/ /4 2-9/32 2-/6 / /2 2-9/6 2-3/6 / /32 2-9/6 /6 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details 35

28 T& Fittings Rigid and Intermediate Metal onduit Fittings 674 Series 675L Series Threaded ouplings (ERIKSON ) ouplings for Threaded Rigid Metal onduit and Intermediate Metal onduit pplication To couple and effectively bond threaded ends of rigid metal conduit/intermediate metal conduit where neither length of conduit can be rotated Features Malleable Iron/Steel/opper-free luminum onstruction Free fitting threads ensure easy assembly. Permits conduit coupling without rotating either conduit Provides rigid in-line coupling with high quality grounding; will not loosen under vibration Suitable for concrete-tight application. apable of carrying ground fault currents up to 0,000 amps RMS (/2 in. through -/2 in. size) and up to 20,000 amps RMS (2 in. and above) (duration of fault current 3 cycles) (674 Series tested) Standard Material 674 Series ushing and ody Malleable Iron Ring Steel up to 2 in. or Malleable Iron 675L Series ushing and ody luminum Ring luminum Standard Finish 674 Series: Electro Zinc Plated & hromate oated 675L Series: Degreased Range 674 Series: 3/8 in. thru 6 in. onduit 675L Series: /2 in. thru 6 in. onduit ll straight pipe threads (NPS) onformity UL 54 S 22.2 No. 8.3 NEM F NSI 80.4 NFP (NSI) Federal Specification W-F-408 Federal Standard H-28 (Threads) ERIKSON ouplings With an Erickson coupling, a conduit run may be completed when neither conduit can be turned. conduit run may also be broken without taking down the whole run. onduit joined with Erickson ouplings is rigid and in line and vibration will not loosen the connections. Mal. Iron lum.* 674 3/8 -/8 -/ L /2-5/32 -/ L 3/4-9/6-3/ L -29/32-5/ L -/4 2-3/8-3/ L -/2 2-5/8-3/ T 680L 2 3-7/32 2-7/ L 2-/2 3-3/32 2-/ L 3 4-7/6 2-29/ L 3-/ L 4 5-/2 3-3/ L 4-/2 6-/4 3-5/ L /32 3-3/ L /32 * opper-free luminum (less than 0.4% opper) UL Listed and S ertified concrete-tight Not S ertified 36

29 T& Fittings Rigid and Intermediate Metal onduit Fittings Panel Fitting Extensions 440 /2 -/4-3/6-7/8 44 3/4 -/4-3/32-5/ /6-2/32-5/ /4 -/4 2-/8 2 Ideal when longer thread length is needed. Will combine with any fitting having a male thread. Male thread of panel fitting extension is in. long. Malleable iron Male Enlargers 245 /2 -/4-3/6-7/ /4 -/4-3/32-5/ /6-2/32-5/ /4 -/4 2-/8 2 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details dapt an outlet hole to the next larger size of conduit. Rough ends of conduit caarefully covered by built-in bushing. Malleable iron Female Reducers dapt an outlet hole to the next larger size of conduit. Rough ends of conduit caarefully covered by built-in bushing. Malleable iron 250-T 3/4 to /2 -/8 5/8 3/6 26 to /2-7/6-7/6 3/6 25 to 3/4-3/8 /6 3/ /4 to /2-3/6 2/32 3/ /4 to 3/4-3/6 23/32 3/ /4 to -3/4 25/32 7/ /2 to -/4 2 3/6 / to -/2 2-3/8-3/6 9/ /2 to 2 3 -/4 3/ to 2-/2 3-5/8 -/2 / /2 to 3 4-/8-9/6 / to 3-/2 4-5/8-3/6 /2 For Dura-Plate finish, add prefix 040- to onsult your Regional Sales Office for details 37

30 T& Fittings Rigid and Intermediate Metal onduit Fittings Threaded Reducers For reducing the threaded opening in conduit bodies or any female threaded fitting. Smooth, built-in bushing completely covers rough ends of conduit. Iron or steel construction. Steel from 600-T thru 606-T, also 64 & 65. Stl. or M.I. lum. Size (in) 600-T 600L-T /2 to 3/8 5/8 60-T 60L-T 3/4 to /2 9/ T 602L-T to /2 9/ T 603L-T to 3/4 9/ T 604L-T -/4 to /2 9/ T 605L -/4 to 3/4 9/ T 606L -/4 to / L -/2 to /2 5/ L -/2 to 3/4 5/ L -/2 to -3/ L -/2 to -/4 27/32 6-T 6L 2 to /2 23/ L 2 to 3/4 -/ L 2 to -/6 64-T 64L 2 to -/4 -/6 65-T 65L 2 to -/2 27/32 Reducing Washers Washers reduce knockout hole in outlet box. Newly designed of galvanized steel. These washers, used in pairs, interlock and form a rib which centers the washers and conduit in the knockout /4 to 3/8 45/64-3/ /4 to /2 7/ to 3/8 45/ to /2-5/8 7/ to 3/4-3/ T -/4 to 3/8 45/ /4 to /2 7/ /4 to 3/4-3/ /4 to -23/ /2 to 3/8 45/ /2 to /2 7/8 37 -/2 to 3/4 2-/4-3/ /2 to -23/ /2 to -/4-23/ to /2 7/8 375-T 2 to 3/4-3/ to 2-3/4-23/ to -/4-23/ to -/2-3/32 38

31 T& Fittings Rigid and Intermediate Metal onduit Fittings onduit Straps for Threaded Rigid Metal onduit and Intermediate Metal onduit 275 Series 276L Series () onduit Strap onduit onduit Spacer pplication To support and securely fasten rigid metal conduit and intermediate metal to the supporting surface Features Rugged malleable iron/copper-free aluminum construction snugly fits on the conduit Designed to prevent accumulation of moisture and start of corrosion on vertical run of conduit () Standard Material 275 Series Malleable Iron 976L Series ll copper-free aluminum Standard Finish 275 Series Hot Dipped Galvanized 276L Series s ast Range 275 Series 3/8 in. through 6 in. conduit 276L Serie /2 in. through 6 in. conduit onformity S 22.2 No. 8.3 NSI 80.4 NFP (NSI) Supporting Wall Pipe Straps Malleable Iron or luminum Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. Hot-dipped galvanized finish. Screw Mal. Iron lum L 3/8-5/6 9/32 / L /2 2-/32 23/32 / L 3/4 2-/6 2/32 5/8 / L 3-3/32 /6 3/ L -/4 4-/8 3/6 29/32 5/ L -/2 4-/2 5/6-7/32 3/ L 2 5-3/6 -/8 -/4 7/6 282* 282L 2-/2 5-5/6 -/2-3/4 283* 283L 3 6-/6-5/8 2-3/6 / L 3-/2 7-9/32-3/4 2-3/4 285* 285L 4 8-5/6-7/8 2-3/6 286** 286L** 4-/2 9-3/6-5/6 2-5/6 5/ L 5 9-5/6 2 3-/ L 6 -/2 2-7/6 4-/8 * May be used with EMT of same size Not snap on type UL not applicable ** Not S ertified 39

32 T& Fittings Rigid and Intermediate Metal onduit Fittings Pipe Straps Steel onduit Size (in.) 20 3/8-5/32 3/4 /6 2 /2 2 3/4 5/6 22 3/4 2-5/6 3/ /6 3/4-7/64 24T* -/4 2-3/32-9/6-9/6 25T* -/2 3-23/32-3/6-3/6 26T* 2 4-7/6 2-5/6 2-5/6 Not snap on type UL not applicable * Not S ertified Screw /4 3/8 Elongated bolt hole makes alignment easy, even when holes in mounting surface are off center. Snap on features. Steel. Zinc plated. orrosion Resistant PV oated Rigid onduit Straps olt Size (in.) 275R 3/8 2 2/32 /4 276R /2 2-3/32 25/32 /2 /4 277R 3/4 2-3/4 23/32 5/8 278R 3-5/32 3/4 3/6 279R -/4 4-5/32 25/32 7/8 3/8 280R -/2 4-9/6-7/32 28R 2 /2 5-/4-3/6 -/4 UL not applicable Malleable iron. Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. 40

33 T& Fittings Rigid and Intermediate Metal onduit Fittings onduit Spacers for Rigid Metal onduit, Intermediate Metal onduit and Electrical Metal Tubing () { 350 Series 350L Series pplication Provides mounting surface for conduit where installation requires air space between conduit and supporting surface Features Prevents conduit rusting from wall condensation Spacers can be stacked one atop the other facilitating installation and eliminating expensive conduit off setting () Designed to cover wide range; marked with accurate size marking for proper positioning () Standard Material 350 Series Malleable Iron 350L Series opper-free aluminum Standard Finish 350 Series Hot Dipped Galvanized 350L Series s ast Range /2 in. through 6 in. conduit onformity S 22.2 No. 8.3 NSI 80.4 NFP (NSI) () _ 3 8 _ 3 4 _ 2 4

34 T& Fittings Rigid and Intermediate Metal onduit Fittings Pipe Spacers Screw Mal. Iron lum. Size L 3/8, /2, 3/4, #7 3 7/ L -/4--/2-2 #2 5-3/ L 2-/2-3 #2 9-9/6-3/ L 3-/2-4 #4 7-9/6 2 onforms to E Rule 2-02 (5) UL not applicable Used with T& conduit straps to permit space between conduit and mounting surface. Eliminates need for costly offset-bending conduit and possible corrosive moisture traps when conduit is mounted directly to a surface. Hot-dipped galvanized finish, premountable and stackable to eliminate offsetting. Pipe Spacers PV oated onduit Screw Size 350R /2-3/4- #7 3 7/8 35R -/4--/2-2 #2 5 3/8 352R 2-/2-3 #2 6-9/6-3/4 353R 3-/2-4 #4 7-9/6 2 onforms to E Rule 2-02 (5) UL not applicable orrosion resistant PV coated malleable iron. Pre-mountable, stackable to eliminate offsetting. Spacers can be stacked for offsets on wall or into outlet box. Prevents conduit rusting from wall condensation. Eliminates offsetting of conduit. 42

35 T& Fittings Rigid and Intermediate Metal onduit Fittings Tite-ite ombination ouplings rmoured able for Threaded Rigid 440 /2-5/8-27/ /4-3/4 2-/ /32 one-piece fitting that couples armoured cable or flexible conduit to threaded rigid conduit. Tite-ite wedge holds conduit securely with a double grip. With a hase nipple, this fitting will connect flexible conduit to outlet boxes, allowing more wiring space in the box than the usual fitting. Malleable iron. eam lamps djustable Includes bolts Steel Description 700T Fits Flange 2-3/4 in /8 in. 703* Special olt and 3 Nuts * Not S ertified onduit Supports 690T /2 69T 3/4 692T 693T -/4 These supports will fit any flange, tapered or straight up to 5/8 in. thick. The broad hook holds the conduit at any desired angle. Holds standard rigid conduit, EMT, or I.M.. Malleable iron. 43

36 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding ONRETE TIGHT ONRETE TIGHT RIN TIGHT ase : Where threaded or threadless conduit terminates into a threadless opening in a sheet metal box or enclosure with or without concentric or eccentric knockouts Threadless opening in a sheet metal box or enclosure onding jumper around concentric or eccentric rings required by E Rule Method of onding For 20/208 volts or 20/240 volts circuits provided no unpunched rings remain around the knockout For under or over 250 volts circuits, service equipment and hazardous locations (where applicable) provided no unpunched rings remain around the knockout For under or over 250 volts circuits, service equipment and hazardous locations (where applicable) with or without unpunched rings around the knockout { () Threaded or threadless rigid metal conduit or intermediate metal conduit (2) T& Series 823 or 824 Threadless Fittings (3) T& Series 825 Set Screw Fitting (4) T& Series 370 or H050-T Sealing Hub (ullet Hubs) (5) T& Series 40 Locknuts (6) T& Series 06 onding Locknut (7) T& Series 3870 onding & Grounding ushing (8) T& Sta-Kon or olour-keyed lug 44

37 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) ONRETE TIGHT ONRETE TIGHT RIN TIGHT ase 2: Where threaded or threadless conduit terminates into a threaded hub in a cast metal enclosure Threaded hub in a cast metal enclosure Methods of onding For () 20/208 or 20/240 volts circuits (E 0-60) (2) Over 250 volts circuits (E 0-60) (3) Service equipment (E 0-604) (4) Hazardous Locations (where applicable) 8-24 (lass I, Zone ) 8-60 (lass I, Zone 2) 8-28 (lass II, Division ) (lass II, Division 2) 8-36 (lass III, Division ) (lass III, Division 2) () Threaded or threadless rigid metal conduit or intermediate metal conduit (2) T& Series 823 Threadless Fitting (3) T& Series 825 Set Screw Fitting 45

38 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) ase 3: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings remaining around knockout. 2 Threadless opening in a sheet metal box or enclosure OR 4 Method of bonding for 20/208 volt or 20/240 volts circuits (other than service equipment). Method of bonding for over 250 volts circuits e.g. 600/347 volt systems and those operating over 600 volts (other than service equipment). Note: ny of the bonding methods described for service equipment may also be used 46

39 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) ase 3: (cont d) Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings remaining around knockout OR () Threaded rigid metal conduit or intermediate metal conduit (2) T& Series 42 Locknuts (3) T& Series 22 ushing Metallic (4) T& Series 222 ushing Plastic (5) T& Series 06 onding Locknut (6) T& Series 3650 onding Wedge Methods of onding For (i) Over 250-volts circuit e.g. 347/600-volts systems and those operating over 600 volts (ii) Service equipment (iii) Hazardous locations where applicable 47

40 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) ase 4: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with concentric or eccentric rings remaining around knockout. Methods of bonding for under or over 250-volts, for service equipment and for hazardous locations where applicable. Note: onding jumper required by E Rule () Threaded rigid metal conduit or intermediate metal conduit (2) T& Series 42 Locknuts (3) T& Series 22 ushing, Metallic (4) T& Series 3650 onding Wedge (5) T& Series 3870 onding and Grounding ushing (6) T& Typical Mechanical or Pressure Type Fitting Note: For raintight applications, a sealing ring, T& Series 5302, may be used between outside of box or enclosure and the outside locknut. 6 48

41 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) Service conduit (Threaded rigid metal conduit or intermediate metal conduit) onding Service Equipment (E Rule 0-604) Service equipment enclosure onding required by E Rule onding Method per E Rule Load side of service equipment 2 Install onding Jumper to ssure Electrical ontinuity etween Isolated Sections of Raceways (E Rule 0-64) Threaded rigid metal conduit or intermediate metal conduit 2 Threaded rigid metal conduit or intermediate metal conduit Neutral us Ground us Equipment bonding jumper onding required by E Rule onding Method per E Rule Grounding Electrode onductor us ar Grounding lamp D Grounding Electrode onductor Enclosure onding jumper required by E Rule E Rule Multiple onding of Service Raceways Where Service Entrance onductors are Paralleled in Two or More Raceways, E Rule 0-64 Grounding Electrode Service enclosure (i) (ii) Installing bonding jumper around unpunched concentric or eccentric knockouts in sheet metal box or enclosure [E Rule 0-806] Installing bonding jumper in hazardous locations where locknut bushing or double locknut type of contact is unacceptable method for bonding purposes [E Rule 8-074] Ground us 2 Threaded Rigid Metal onduit or Intermediate Metal onduit Service onduits Rigid metal conduit or Intermediate Metal onduit Suggested Specifications Insulated grounding and bonding bushing (Series 3870) Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing such as Series 3870 manufactured by Thomas & etts. T& Series 42 Locknut 2 T& Series 3870 onding and Grounding ushing (Threaded) 3 T& Series 5262 Sealing O Ring 4 T& Typical olted or Pressure Lug Grounding and bonding bushings used shall be approved for the purpose and () Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion (2) ushing insulator shall be listed or certified for 50 /302 F application with a flammability rating of 94V-O. Insulator must be positively locked in place 49

42 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) Service Raceway (Rigid Metal onduit or intermediate metal conduit) 3 2 () T& Series 42 Locknut (2) T& Series 06 onding Locknuts (3) T& Series 22 ushing 2 3 Ground us Grounding electrode onductor Enclosure Grounding electrode onductor Service enclosure with no unpunched rings around knockout Suitable for onding Raceway, EMT or Terminating Fitting to a sheet metal box or enclosure where (a) No unpunched concentric or eccentric rings remain around the knockout (b) Ordinary locknut is unacceptable for bonding purposes such as (i) Service Equipment Enclosures E Rule 0-64 (ii) onding for circuits over 250 volts (where required) E Rule 0-64 (iii) onding in Hazardous Locations regardless of the voltage of the system E Rule Suggested Specifications onding Type Locknut (Series 06) Where drawings indicate installation of a bonding type locknut to effectively bond a terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter, the locknuts installed shall be of hardened steel/malleable iron construction, electro-zinc plated, such as Series 06 manufactured by Thomas & etts. 50

43 T& Fittings Rigid and Intermediate Metal onduit Fittings Methods of onding and Grounding (cont d) 2 Ground us 3 2 T& Series 365 onding & Grounding Wedge 3 Service Raceway (Rigid Metal onduit or Intermediate Metal onduit) 4 Service Enclosure Service Equipment onding Jumper Grounding electrode conductor 2 Grounding electrode onductor enclosure (Rigid Metal onduit or Intermediate Metal onduit) Threaded Rigid Metal onduit or intermediate Rigid Metal onduit Sheet Metal ox or 4 Enclosure with unpunched concentric or eccentric rings remaining around knockout opening cceptable Method for onding Following (i) Service Equipment E Rule 0-64 (ii) onding for ircuits over 250 volts E Rule 0-64 (iii) onding in Hazardous Locations E Rule When installed with a bonding jumper, acceptable method of bonding where unpunched rings remain around concentric or eccentric knockouts in sheet metal boxes or enclosures. [E Rule 0-64]. Suggested Specifications onding and Grounding Wedge (Series 3650) onding and Grounding Wedges installed to effectively bond terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter or to install bonding jumper around concentric or eccentric knockouts shall be of the type as manufactured by Thomas & etts Series onding and Grounding Wedge shall be of rugged bronze/tin-plated or steel/electro-zinc plated. Phase onductors Equipment onding Jumper () T& Series 42 Locknut (2) T& Series 22 Metallic ushing (3) T& Series 365 onding & Grounding Wedge (4) T& Pressure (crimp type) Terminal Lug 5

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples...

Conduit End Bells...EA1 Hex Reducing Bushings...EA2 Conduit Hubs...EA3-EA4. Split Couplings...EA5 Three Piece Couplings...EA6 Conduit Nipples... SECTION E INDEX Product Description Page Number Conduit End Bells.......................................EA Hex Reducing Bushings..................................EA2 Conduit Hubs......................................EA-EA4

More information

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG Waterpipe Ground Ground Wire Size Water Pipe Size 2-T 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 WG 2-1/2 in., 3 in. or 3-1/2 in. 5-T 4 in., 4-1/2 in. or 5 in. 6 6

More information

E.M.T. Set-Screw Connectors. Technical Specifications

E.M.T. Set-Screw Connectors. Technical Specifications Set-Screw onnectors Regular Insulated I5404 (-IT) / I5408 (-IT) Steel Locknut I5004 (-IT) / I5008 (-IT) I5020 (-IT) / I5032 (-IT) I5410 (-IT) / I5432 (-IT) Steel Locknut I5010 (-IT) / I5016 (-IT) I5054

More information

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY Comparison & Strategy Andrea Briggs Associate Product Manager - Conduit & Fittings Liquidtight Fitting Brand Strategy Component Comparisons Summary Liquidtight Fitting Brand Strategy Steel City Liquidtight

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

RACO Commercial Fittings

RACO Commercial Fittings RACO Commercial Fittings B2 GENERAL INFORMATION - STANDARDS, 1999 NATIONAL ELECTRICAL CODE General Information When you need to couple, connect, fasten, or ground conduit or cables, RACO fittings are your

More information

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT) ommercial Grade Fittings Set-Screw Fittings I5404 / I5408 I5404IT / I5408IT I5004 (-IT) / I5008 (-IT) I5410 / I5432 I5410IT / I5432IT I5010 (-IT) / I5016 (-IT) Regular Insulated Set-Screw Fittings (Steel)

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project SOLAR RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project Commercial, Industrial and Residential Electrical Products RACO

More information

RACO Commercial Fittings

RACO Commercial Fittings 06 Pg B1 - B20.qxp 6/9/2008 9:47 AM Page B1 RACO Commercial Fittings 06 Pg B1 - B20.qxp 6/9/2008 9:47 AM Page B2 B2 dbkbo^i=fkcloj^qflk=j=pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab déåéê~ä=fåñçêã~íáçå tüéå=óçì=åééç=íç=åçìéäéi=åçååéåíi

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

Holemaking Products & Accessories

Holemaking Products & Accessories Holemaking Products & Holemaking Products & Made of top-of-the-line materials for longer lasting performance, Klein's diverse line of drill bits and holemaking products and accessories provide accuracy

More information

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies

More information

TNC Connectors. General Description. TNC Configurations. TNC Specifications* Plug Interface** Jack Interface**

TNC Connectors. General Description. TNC Configurations. TNC Specifications* Plug Interface** Jack Interface** TN onnectors General Description Delta TN connectors are compact, 50 Ω impedance connectors with 7 16-28 threaded coupling, similar in size to N connectors but with better electrical characteristics. They

More information

INTERMEDIATE METAL CONDUIT

INTERMEDIATE METAL CONDUIT PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS

More information

FSK1VDRA 1G Al DPLX RCPT CVR

FSK1VDRA 1G Al DPLX RCPT CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FSK1VDRA 1G Al DPLX RCPT CVR Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category FSK1VDRA

More information

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves

5.1 MUELLER CORPORATION VALVES. MUELLER 300 Ball Type Corporation Valves MUELLER CORPORATION VALVES 5.1 Shaded area indicates changes Rev. 4-14 Machine inserted corporation stops were developed by Hieronymus Mueller in conjunction with his development of the drilling and tapping

More information

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End; 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height

More information

ASAP Sr. A Strap and Pole. Magic Christmas. Single Stage. Walter Monkhouse. Alexandria, La. Version 1.2.

ASAP Sr. A Strap and Pole. Magic Christmas. Single Stage. Walter Monkhouse. Alexandria, La. Version 1.2. ASAP Sr Single Stage A Strap and Pole Version 1.2 Walter Monkhouse Walter@MagicChristmas.org Magic Christmas Alexandria, La. Description The ASAP Sr, single stage, has the same concept as the ASAP Jr.

More information

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth STRENGTH Diamond serrated jaws provide a firm grip PLIERS AND SNIPS Locking Pliers Slip Joint Pliers Electrician s Pliers

More information

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018 SECTION 055000 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING SECTION 230516 - EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING PART I - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

Type XTSR71 Sizes

Type XTSR71 Sizes (Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts

More information

Rayport G Eco Dealer Kit

Rayport G Eco Dealer Kit Rayport G Eco Dealer Kit Installation Guide www.aetenergy.com Supporting a Cleaner, Greener Tomorrow 1. Table of Contents 1. Table of Contents P2 2. Installer Notes P3 3. Parts List P4-7 4. Tool List P8

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. Hand or power. kpa/34. MUELLER SMALL DRILLING MACHINES 2.1 Shaded area indicates change Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines

More information

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles.

More information

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum

Clamp Pair. Bore Diameter (mm) Clamp Material PP = Polypropylene PA = Polyamide PE = Polyethylene AL = Aluminum DIN 0 CLAMPS Clamp Pairs HRL = Standard Duty (Ribbed Profile) HRGL = Standard Duty (Smooth Profile) HRS = Heavy Duty (Ribbed Profile) HRGS = Heavy Duty (Smooth Profile) Clamp Pair ore Diameter (mm) Clamp

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub Tuf-Lite II Fans H Hi Temp 3000HT Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II Hi Temp Fan Blades Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Hi Temp fan blades (Red) are

More information

Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray.

Model Color Wire Combination Range Wire Combination Range (mm) Quantity Cat. No. Box of V. Carton of 1, Gray. Wire-Nut Wire Connectors Yellow and red Wire-Nut Wire Connectors can easily be applied using the Twist-a-Nut Screwdriver. Five color-coded models cover wire sizes from 22 to 6 AWG Fixed, square-wire spring

More information

BNC Connectors. General Description. BNC Configurations. BNC Specifications* Plug Interface** Jack Interface**

BNC Connectors. General Description. BNC Configurations. BNC Specifications* Plug Interface** Jack Interface** N onnectors General Description Delta N connectors are compact, economical, 50Ω impedance connectors with two-stud bayonet coupling. They are best suited for use with cables in the range of.150" to.50"

More information

A. Product Data: For each electrical identification product indicated.

A. Product Data: For each electrical identification product indicated. SECTION 16075 - ELECTRICAL IDENTIFICATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

o r r o s i o n s o l u t i o n s 805.409.4050 www.okote.net I I the o kote AdVAntAGE A tradition of High standards in orrosion Protection orrosive elements cause millions of dollars in damage through

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

SECTION 7. SAFETYING

SECTION 7. SAFETYING 9/8/98 AC 43.13-1B SECTION 7. SAFETYING 7-122. GENERAL. The word safetying is a term universally used in the aircraft industry. Briefly, safetying is defined as: Securing by various means any nut, bolt,

More information

Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions

Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions Motorized M3 AX7200 Rotary-Style Gasket Cutter Operating Instructions INTRODUCTION Congratulations! You are the owner of the finest rotary-style gasket cutter in the world. Originally developed and patented

More information

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C)

Max. Rec. Load. Wt. Per Inch lbs. kn lbs. kn lbs. kg. Wt. Per Inch lbs. kn lbs. kn lbs. kg 750 F (399 C) FIG. 10 FIG. 15 & 15L Function: Designed for use in pipe hanger assemblies. (Type 304 or 316 Stainless Steel upon request) Ordering: Specify figure number, rod size, length (), material, and finish. 650

More information

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

TNC SERIES General... 4 Interface... 5 Characteristics...6-7 CONTENTS PAGE TNC SERIES General... 4 Interface... 5 Characteristics...6-7 TNC 50 Ω SERIES Plugs...8-9 Jacks...0- Jacks and receptacles... Receptacles...-4 Adapters... 5 Caps... 6 TNC 75 Ω SERIES Plugs...

More information

HDL(M)6 Nut/Screw Assembly

HDL(M)6 Nut/Screw Assembly HDL(M)6 Nut/Screw Assembly Remove, repair, and reassemble the nut and screw assembly in your HDL series double lock vise. In these instructions when we refer to the front of the vise or nut/screw assembly,

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw.

More information

Complete line of Holemaking Products and Accessories

Complete line of Holemaking Products and Accessories Complete line of Holemaking Products and Accessories I N T R O D U C I N G Holemaking Products Klein Tools has expanded our line of Holemaking products. We have added new flexible drill bits and related

More information

HANDHOLE SEAT GRINDER

HANDHOLE SEAT GRINDER 1041-1601 HANDHOLE SEAT GRINDER OPERATING INSTRUCTIONS & SERVICE MANUAL Rev: A, 9/17/2007 TO REDUCE THE RISK OF INJURY AND EQUIPMENT DAMAGE USER MUST READ AND UNDERSTAND OPERATOR S MANUAL. Thomas C. Wilson,

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

TOOLS AND INSTALLATION

TOOLS AND INSTALLATION TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and

More information

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure.

The MUELLER method of making a main to service connection using the MUELLER E-5 Small Drilling Machine. The main is drilled out under pressure. MUELLER SMALL DRILLING MACHINES 2.1 Rev. 9-09 MUELLER Co. manufactures several different small drilling machines for drilling holes from 7/16" to 2" in all types of pipe. Machines are available in hand

More information

Product Guide Specification

Product Guide Specification Zurn Industries, LLC November 2014 1801 Pittsburgh Avenue Erie, PA 16502 Toll Free (855) 663-9876 Phone (814) 455-0921 Fax (814) 871-6141 Website www.zurn.com Product Guide Specification Specifier Notes:

More information

22 22, 24, , 18, AWG. 50 ohm 50 ohm. 75 ohm 75 ohm. 95 ohm 95 ohm

22 22, 24, , 18, AWG. 50 ohm 50 ohm. 75 ohm 75 ohm. 95 ohm 95 ohm ircular onnectors MR 4 Series onnectors General Information high density (.080 [2.0] contact centers), lightweight, subminiature, cylindrical connector series featuring crimp contacts and fingertip, push-pull,

More information

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11

Linear Motion and Assembly Technologies Aluminum Framing /07. Die-Cast Foundation Brackets 3-10 & 3-11 -0 Linear Motion and ssembly Technologies luminum Framing 91 500 1 /07 Section : Profile onnectors Overview One of the greatest strengths of the osch Rexroth structural aluminum framing system is the wide

More information

Removing and Replacing the Y-truck

Removing and Replacing the Y-truck Service Documentation Removing and Replacing the Y-truck To remove and replace the Y-truck you will need the following tools: 4mm Allen wrench 12mm stamped flat wrench #2 Phillips screwdriver (magnetic

More information

Clocking a TD-04 Turbo Compressor Housing. Appendix A : AWIC Silicone and Tubing Fitting

Clocking a TD-04 Turbo Compressor Housing. Appendix A : AWIC Silicone and Tubing Fitting Clocking a TD-04 Turbo Compressor Housing Appendix A : AWIC Silicone and Tubing Fitting Revision A: 7-13-2015 Tools: Metric Sockets (10, 12, 14, 17mm) 5mm Hex Key Large Internal Snap Ring Pliers 3/8 Socket

More information

ANCHORS SLEEVE ANCHORS BOLT DIAMETER

ANCHORS SLEEVE ANCHORS BOLT DIAMETER SLEEVE ANCHORS No hole spotting. No mis-alignments. Simply drill through the fixture into concrete, insert and tighten. Preassembled for fast, easy installation. No special tools necessary; meets federal

More information

Holemaking Products & Accessories

Holemaking Products & Accessories Holemaking Products & Made of top-of-the-line materials for longer lasting performance, Klein's diverse line of drill bits and holemaking products and accessories provide accuracy and consistency to get

More information

Carton of 1, B. Min. 2-,34mm 2 Max. 3-1,5mm V 22 to 14 AWG Min. 2 #22 Max. 3 #16. ,34mm 2 to 2,5mm 2. Min.

Carton of 1, B. Min. 2-,34mm 2 Max. 3-1,5mm V 22 to 14 AWG Min. 2 #22 Max. 3 #16. ,34mm 2 to 2,5mm 2. Min. Wire-Nut Five color-coded models cover wire sizes from 22 to 6 AWG Fixed, square-wire spring creates its own threads maintains a secure positive grip that will not relax over time No pre-twisting required

More information

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602

Installation Tools. Pipe Cutters for steel and cast iron pipes 598. Deburring Reamer / for stainless steel pipes 600. for copper pipes 602 596 597 Installation Tools Pipe Cutters for steel and cast iron pipes 598 Pipe Cutters / Pipe Deburring Reamer for stainless steel pipes 600 Pipe Cutters / Pipe Deburring Reamer / Calibrating Tool for

More information

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL

4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL 4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL 4.4.1 EXPLODED VIEW DRAWING REF. QTY. DB DC DF DG DJ DL DESCRIPTION PART # 1 1 ADAPTOR FRAME 034007 2 12 LOCK WASHER 3/8 x 1/8 S.S. 034004 3 12 HEX HEAD

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions conduit? 9/8/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Can branch circuits of different services be installed in the same Yes, see 300.3(C)(1) for conductors of different systems

More information

1. TABLE OF CONTENT 2. ASSEMBLY ATEX. PENCOflex Installation Instructions & Service Manual

1. TABLE OF CONTENT 2. ASSEMBLY ATEX. PENCOflex Installation Instructions & Service Manual ATEX 1. TABLE OF CONTENT 1. Table Of content... 1 2. Assembly... 1 3. Alignment... 2 4. Earthing... 3 5. Inspection and replacement of Elastic elements... 4 5.1. Rubber elements... 4 5.2. Pins... 4 5.2.1

More information

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM SIX INCH ALPHA MODULE INSTALLATION KEWAUNEE SCIENTIFIC CORPORATION SIX INCH ALPHA MODULE ANCHORING SYSTEM After Alpha module has been set in desired location. Adjust the four adjustment bolts until the

More information

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder PAC-2 Kit Contents Part Quantity Screws: 8/32 x 3/8 Screws: 8-32 x 5/6 Screw: 8-32 x /4 #8 internal tooth washers #8 solder lug ring terminals Bolt: Aluminum, /4-20 x.5 /4 internal tooth washer Nut: Aluminum

More information

Hose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End

Hose Accessories. Air King 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End "Air King" 4 - Lug Quick-Acting 1¼" 1½" AM16 AM AM6 AB16~ AB~ AB6 End Rubber Washers for 4-Lug AWR14 Fits all sizes 1¼" 1½" AM18 AM3 AM8 AB18~ AB3 AB8 Rated to 1 PSI Female N.P.T. End "Boss" clamps recommended

More information

Nailbiter Premium Ship Auger Bits. RESI-MASTER Heavy-Duty Ship Augers

Nailbiter Premium Ship Auger Bits. RESI-MASTER Heavy-Duty Ship Augers Nailbiter Premium Ship Auger Bits Dual-Helix construction with twin cutting edges for faster and smoother drilling action, even through nail-embedded timbers Full body, dual induction heat treatment ensures

More information

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT: SLEEVING (CONVOLUTED) Halogen-free nylon convoluted sleeving suitable for bundling of wires and protection against abrasion. Continuous operating temperature -40ºC to 5ºC with short excursions up to 150ºC.

More information

IF YOU DON T SEE IT HERE

IF YOU DON T SEE IT HERE www.smithfast.com Drills & Taps & Bits Screws Cotter Drilling Bolts / Hex Capscrews Lag Carraige Hitch Grade 8 Machine Grade Elevator 5 Sheet Spring Metal Roll Grade Eye 2 Square Taper Head set A325 Hex

More information

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office

More information

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems

FABA. Installation Instructions. Conductor Bar System. Publication #FABA-03 3/1/04 Part Number: Copyright 2004 Electromotive Systems FABA Conductor Bar System Installation Instructions Publication #FABA-03 3/1/04 Part Number: 005-1062 Copyright 2004 Electromotive Systems 1S 100 Z Installation Instructions Contents: Basic Diagram - -

More information

Clamping devices 521

Clamping devices 521 Clamping devices 521 522 Product overview Clamping devices Adjustable straps K0001 Hook clamps K0012 Goose-neck straps with long slot K0002 Page 526 Hook Clamps with collar K0013 Page 535 Equipped clamps

More information

Pliers. Pliers PLIERS

Pliers. Pliers PLIERS Pliers Pliers PILERS Long Nose Pliers With Side Cutter Comfortable two-component handles combine durability with a secure non-slip grip. High-leverage joint placement increases leverage to reduce the cutting

More information

Tube Facing Tool.

Tube Facing Tool. www.swagelok.com Tube Facing Tool This manual contains important information for the safe and effective operation of the Swagelok TF72 series tube facing tool. Users should read and understand its contents

More information

Special Thumb Screw Order Form

Special Thumb Screw Order Form Special Thumb Screw Order Form QUOTE FOR: ORDER FOR: Name: Company: Address: QUANTITY: Phone #: City: State: Zip: Email Address: FILL IN YOUR DIMENSIONS write directly over light blue type* write clearly

More information

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III Hi Temp (Red) fan blades are of single

More information

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains. Universal Carrier Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains. The 400 series carrier accommodates most urinal, water-cooler or hanger plate lavatory

More information

Thomas Disc Couplings Installation and Maintenance Type 54 RDG Sizes (Page 1 of 6)

Thomas Disc Couplings Installation and Maintenance Type 54 RDG Sizes (Page 1 of 6) Thomas Disc ouplings Installation and Maintenance Type 54 RDG Sizes 125-925 (Page 1 of 6) ATEX In order for this coupling to meet the ATEX requirements, it is mandatory to precisely follow these installation

More information

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) No. Trade Dimensions (mm) Size I.D. A B C Threads YCM-03 3/8 11.2 28.3 44.6 13.2 PT 1/2 YCM-04 1/2 14.8

More information

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance. Corrosion Resistant liquid tight conduit fittings for use with flexible liquid tight metallic conduits, flexible liquid tight non metallic or PVC coated flexible metal conduit. * Liquidtight, Raintight,

More information

onlinecomponents.com

onlinecomponents.com Introducing T&B Marrette Wire Connectors In 1914, William Marr invented the world s first pressure type wire connector. Since then, Marrette connectors have become synonymous with best quality wire connector.

More information

FIELD LOK 350. Gasket 4" 24" JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61

FIELD LOK 350. Gasket 4 24 JOINT RESTRAINT NSF FOR WATER & WASTEWATER, FIRE PROTECTION & INDUSTRIAL APPLICATIONS. Certified to ANSI/NSF 61 4" 24" FIELD LOK 350 JOINT RESTRAINT Gasket FOR WATER & WASTEWATER, FIRE ROTECTION & INDUSTRIAL ALICATIONS 4" 24" FIELD LOK 350 Gasket 2 Table of Contents FIELD LOK 350 Gasket 3 Assembly 4 Alternative

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. blue**) fan blades are made from

More information

Replacement of Pitch Link Retainer and Service Improvement of the Pitch Control System. Effectivity: Helicopters manufactured prior to January, 1981

Replacement of Pitch Link Retainer and Service Improvement of the Pitch Control System. Effectivity: Helicopters manufactured prior to January, 1981 Page 1 of 12 Date: December 2, 1981 Subject: Models: Replacement of Pitch Link Retainer and Service Improvement of the Pitch Control System F-28C and 280C Effectivity: Helicopters manufactured prior to

More information

Maintenance Information

Maintenance Information 16575177 Edition 1 June 2006 Electric Angle Wrench QE8 Series Maintenance Information Save These Instructions General Instructions: Refer to Suggested Tools Parts List for quick reference to the tools

More information

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer

REPAIR INSTRUCTIONS. Cat. No Cat. No MILWAUKEE ELECTRIC TOOL CORPORATION. SDS Max Demolition Hammer. SDS Max Rotary Hammer Cat. No. 9-0 SDS Max Demolition Hammer Cat. No. -0 SDS Max Rotary Hammer MILWAUKEE ELECTRIC TOOL CORPORATION W. LISBON ROAD BROOKFIELD, WISCONSIN 00-0 8-9-0 d 000 8-9-0 d Special Tools Require Forcing

More information

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS IMPORTANT INFORMATION Note To Supervisor: Please share this information with your employees and make sure they have received training

More information

MECHANICAL ASSEMBLY John Wiley & Sons, Inc. M. P. Groover, Fundamentals of Modern Manufacturing 2/e

MECHANICAL ASSEMBLY John Wiley & Sons, Inc. M. P. Groover, Fundamentals of Modern Manufacturing 2/e MECHANICAL ASSEMBLY Threaded Fasteners Rivets and Eyelets Assembly Methods Based on Interference Fits Other Mechanical Fastening Methods Molding Inserts and Integral Fasteners Design for Assembly Mechanical

More information

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions

Outline. Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions www.we-llc.com Outline Grounding Washer, Electrical Equipment Bond (WEEB) Acme Cable Clips Acme Conduit Entry (ACE) Questions Bonding & Grounding Grounding Terms Equipment Grounding: The National Electrical

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15 MOUNT INSTALLATION GUIDE PUB5JUN5 Wrenches and Torque SM SOLAR Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

Tel / (USA & CANADA) /

Tel / (USA & CANADA) / Tel.58.847 / 8.388.459 (USA & CANADA) / Email sales@msdiscounttool.com MULTIPURPOSE CLAMPS - USA SERIES 7: Lightweight and 4% stronger than C clamps. Floating jaws that always stay parallel. Designed to

More information

Operating Instructions For Lockformer Button Punch Flanger

Operating Instructions For Lockformer Button Punch Flanger Capacity: 20 to 28 Gauge Galvanize Operating Instructions For Lockformer Button Punch Flanger To satisfactorily form the 90º button punch flange on light gauge materials, it was necessary to form the metal

More information

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue ATLANTIS RAIL Contact Information: Atlantis Rail Systems 70 Armstrong Road 3900 Civic Center Drive Plymouth, MA 02360 North Las Vegas, NV 89030 (800) 541-6829 or (508) 732-9191 (508) 732-9798 www.atlantisrail.com

More information

PRO Series Brakes Operating Instructions

PRO Series Brakes Operating Instructions PRO Series Brakes Operating Instructions Tapco Products Company PRO Brake System PRO Cut Off Gauge Simplifies cutting. PRO Cut-Off Quickly, safely, and easily makes factory quality cuts in coil stock,

More information

Article 225: Outside Branch Circuits And Feeders

Article 225: Outside Branch Circuits And Feeders Part C: Code Book Questions Article 225: Outside Branch Circuits And Feeders 1.! Open (individual) aerial overhead conductors shall be insulated or covered when within! feet of a building.! (a) 10! (c)

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories

4.3 Section CONDUIT INSTALLATION ACCESSORIES. Thinking of the environment. Fixing accessories Coupling accessories CONDUIT INSTALLATION ACCESSORIES Thinking of the environment We use only fully recyclable halogen-free thermoplastics, without harmful additives. No cadmium or asbestos in the colourants either. For total

More information

Innovative Infrastructure for Electric and Hybrid Vehicles PEDESTAL EXTENSION KIT INSTALLATION GUIDE

Innovative Infrastructure for Electric and Hybrid Vehicles PEDESTAL EXTENSION KIT INSTALLATION GUIDE Innovative Infrastructure for Electric and Hybrid Vehicles PEDESTAL EXTENSION KIT INSTALLATION GUIDE PLEASE NOTE: This installation guide includes the latest information at the time of printing. ClipperCreek,

More information