1 SECTION E INDEX Product Description Page Number Conduit End Bells EA Hex Reducing Bushings EA2 Conduit Hubs EA-EA4 Split Couplings EA Three Piece Couplings EA6 Conduit Nipples EA6 Compression Connectors & Couplings EA Set Screw Connectors & Couplings EA8 Conduit Elbows EA9 Offset Nipples EA0 90 Corner Pulling Ells EA U-Bolts & H-Hangers EA2 Beam Clamps EA Conduit Clamps EA4 Conduit Straps EA Conduit Spacers & Nest Backs EA6 Cable Tray Clamps EA8 Combination Couplings EA9 Electroform Inserts EA20 Watertight Hubs EB-EB

2 Notes

3 EA Conduit End Bells Threaded for Rigid Conduit & IMC EA Type TNS For threaded rigid conduit or IMC. Provides a smooth, rounded pulling surface, preventing damage to cable sheath or insulation. Slots are provided for attaching to concrete forms. Malleable or Ductile Iron/ Hot Dip Galvanized Trade Dimensions in Inches Size Catalog Overall Bell Height Max. (Inches) Number (A) (B) Dia. TNS TNS TNS-20 2 TNS TNS TNS TNS TNS Type TNS

4 EA2 Hex Reducing Bushings Threaded for Rigid Conduit & IMC EA2 Type 00R Provided with hex shoulder Malleable Iron/Zinc Electroplated Dimensions in Inches Max. Dim. Trade Size Catalog Across Thread Flange (inches) Number Corners Length Thickness - 20-R - 2-R 6 6 UL Listed: E-8-22-R - 2-R R 6 6 CSA Certified: 99-2-R 6-26-R UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- - 2-R 2-28-R 2-29-R 2-0-R R R R Type 00R 2-4-R R R R R R R R R R R R 4 - -R

5 EA Raintight Conduit Hubs Threaded for Rigid Conduit & IMC EA Type CHM & Type CHM-T Type CHM - General Purpose Fitting. Type CHM-T - Insulated Throat form with Bonding Locknut. Male thread type Tapered female thread for rigid conduit and IMC Recessed O-ring seal assures watertight and dust tight connections Type CHM-T with insulated throat and bonding locknut is suitable for service entrance application Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: 8 UL Listed as suitable for wet locations. CSA Certified: 99 Raintight. Suitable for use in hazardous locations as follows: Class I, Div. 2 Class II, Div., 2 Class III, Div., 2 Per NEC 0-4(b), 02-4(a), 0-(a) UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- NEMA: 4 NEMA: 2 Note: Minimum wall thickness that can be accommodated is. Dimensions in Inches D Female Trade Size Catalog Tapered Max. Box (inches) Number A B C N.P.T. Wall Thk. CHM-0 CHM CHM CHM-2 2 CHM CHM CHM CHM CHM CHM CHM CHM Dimensions in Inches Insulated D Throat Female Trade Size Catalog Tapered Max. Box (inches) Number A B C N.P.T. Wall Thk. CHM-0T CHM-T CHM-00T 2 - CHM-2T 2 CHM-0T 2 2 CHM-200T CHM-20T CHM-00T CHM-0T CHM-400T CHM-00T CHM-600T Type CHM Type CHM-T

6 EA4 Space-Maker Conduit Hubs Threaded for Rigid Conduit & IMC EA4 Type CH & Type CH-T Type CH - General purpose, suitable for use with heavy wall cabinets Type CH-T - Insulated throat form with bonding screw. Provides a more vibration resistant connection with assured ground continuity Female bushed nipple type Female thread for rigid conduit and IMC Takes less space Recessed O-ring seal outside the box provides a watertight threaded hub on enclosures. Suitable for use with service entrance conduit. Malleable Iron/Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 UL Listed as suitable for use in wet locations. CSA Certified: 99 Suitable for use in hazardous locations as follows: Class I, Div. 2 Class II, Div., 2 Class III, Div., 2 Per NEC 0.4(B), 02.4(A) & (B), 0.(A) & (B) UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- NEMA: FB- NEMA: 4 NEMA: 2 Dimensions in Inches A Max. Female Box Trade Size Catalog Tapered Wall (inches) Number B C NPSM Thick. CH-0 CH- CH CH CH CH CH CH CH CH CH CH Dimensions in Inches Insulated A Max. Throat Female Box Trade Size Catalog Tapered Wall (inches) Number B C NPSM Thick. CH-0T CH-T CH-00T CH-2T 2 - CH-0T 2-2 CH-200T 2-2 CH-20T CH-00T CH-0T CH-400T CH-00T CH-600T Type CH Type CH-T Notes: Minimum wall thickness that can be accommodated is.

7 EA Split Couplings For Threaded Rigid Conduit & IMC EA Type SSP A speed union for economically joining two threaded rigid metal conduits. A neoprene gasket provides a concretetight seal at the joint Use where conduit runs are closely spaced Use where conduit is tight against wall, ceiling or other obstruction Use where conduit cannot be turned SSP-00 thru SSP-600: Malleable or Ductile Iron/Zinc Plated SSP-0 and SSP-: Steel/Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 UL Listed as Concretetight. CSA Certified: 99 Trade Size Catalog Dimensions in Inches (inches) Number Length Max. Width Dia. SSP-0 SSP- 2 6 SSP-00 2 SSP SSP SSP SSP SSP SSP SSP SSP SSP Type SSP-0 Type SSP-600 Type SSP-00 and SSP-2 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Installation Instructions: The inside diameter of the split coupling is greater than the outside diameter of the conduit with which it is to be used. To assemble - slip the coupling over one of the threaded conduit ends, butt the two conduit ends together, slide the coupling back over the joint and tighten the hex nut(s). The threaded interior of the split coupling matches with the conduit threads and makes a close fitting mechanically rigid connection with sufficient thermal capacity (I 2 T) to carry ground fault currents equal to wire sizes required by Underwriters Laboratories, Inc. Standard 46 - Table IV, and National Electrical Code Table Existing Conduit Type SSP-0 and SSP- Application Illustration

8 EA6 EA6 -Piece Couplings & Bushed Conduit Nipples Threaded for Rigid Conduit & IMC Type 4 -piece Coupling Couples conduit when neither can be turned. Threaded (NPS) for rigid conduit and IMC Couples conduits when conduits can not be turned Concretetight Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: 99 Trade Size Catalog Overall Max. (inches) Number Length Dia Type 4 Type Bushed Conduit Nipples Use through knockout to connect box to conduit coupling. Use with a locknut to connect two boxes side by side or back to back. Use with a locknut to connect fixture housings in continuous runs. Available with Insulated Throat. With rigid conduit threads (NPS) Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: 99 Insulated Dimensions in Inches Throat Max. Dia. Trade Size Catalog Catalog Across Thread Flange (inches) Number Number Corners Length Thickness T - -T T -2-2T T T T T T T T T Not CSA Certified Type UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec. W-F-408E NEMA: FB-

9 EA EA Compression Rigid Connectors & Couplings For Threadless Rigid Conduit Type Gland Compression Connectors To connect threadless rigid conduit to boxes and enclosures. Concretetight Male hub threads (NPS through 2 ; NPT above 2 ). Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Max Thread (inches) Number Number Length Dia. Length T -0-0T T T T T T T T T T T Not UL Listed Type -00 Type -200 Type -20 Type -600 UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB- Type 0 Gland Compression Couplings To couple sections of threadless rigid conduit together. Concretetight Malleable Iron/Zinc Electroplated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Trade Size Catalog Dimensions in inches (inches) Number Length Max. Dia Not UL Listed Type 0-00 Type Type 0-20 Type UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB-

10 EA8 Set-Screw Rigid Connectors & Couplings For Threadless Rigid Conduit & IMC EA8 Type 28 To connect threadless rigid conduit to boxes and enclosures. Concretetight. Available with insulated throat. Male hub thread (NPS) Malleable Iron/Zinc Plated Optional Finish: - Mechanically Galvanized 2-6 Hot Dip Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Throat Dimensions in Inches Trade Size Catalog Catalog Body Max Thread (inches) Number Number Length Dia. Length T T T T T T T T T T T T 4 Type Type Type Type UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB- Type 29 To couple sections of threadless rigid conduit together. Concretetight Malleable Iron/Zinc Plated Optional Finish: Optional Finish: - Mechanically Galvanized 2-6 Hot Dip Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Trade Size Catalog Dimensions in Inches (inches) Number Length Max. Dia Type Type Type Type UL Standard: 4B Fed. Spec: W-F-408E NEMA: FB-

11 EA9 EA9 90 Bushed & 90 Corner Pull-in Conduit Elbows Threaded For Rigid Conduit & IMC Type 9 Available with insulated throat Threaded for rigid conduit, Female NPT Male NPS Telephone elbow, floor outlet fittings Malleable Iron/Zinc Electroplated Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C T 9-9-T T T 6 6 Optional Finish: Mechanically Galvanized. Contact your local representative for pricing and availability. Type 9 UL Listed: E-8 and 8 CSA Certified: 99 UL Standard: 4 CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB- Type CE Malleable Iron/Zinc Electroplated UL Listed: E-8 Trade Size Catalog Dimensions in Inches (inches) Number A B CE CE CE UL Standard: 4B NEMA: FB- Type CE

12 EA0 Offset Nipples Threaded For Rigid Conduit Type ON Rigid conduit threading. Provides box-to-box connection of knockouts. Allows misaligned knockout connection by rolling the offset nipple until aligned with each knockout. Feature: Available with insulated throat. Malleable Iron/Zinc Plated Optional Finish: Mechanically Galvanized. Contact your local representative for pricing and availability. UL Listed: E-8 Insulated Dimensions in Inches Throat Thread Trade Size Catalog Catalog Body Length Type (inches) Number Number Length Each End Thread ON-0 ON-0T 6 ON- ON-T ON-00 ON-00T ON-2 ON-2T ON-0 ON-0T 2 ON-200 ON-200T NPS NPT 9 6 NPT 6 NPT NPT 6 NPT Type ON EA0 CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E NEMA: FB-

13 EA 90 Raintight Corner Pulling Ells Threaded For Rigid Conduit & IMC EA Type FF 90 Female/Female Trade Size Catalog Dimensions in Inches (inches) Number A B Provides a compact wire-pulling point and a 90 change of direction in a conduit run. Threaded for rigid conduit and IMC (NPT) Furnished with Neoprene gasketed steel cover, zinc electroplated. Raintight Malleable Iron/Zinc Plated UL Listed: E-8 FF-00 6 FF FF FF FF FF FF-20 6 FF Type FF CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Type MF 90 Male/Female For connecting rigid conduit or IMC to box or enclosures. Threaded for rigid conduit and IMC Female NPT, Male NPSM Furnished with neoprene gasketed, steel cover, zinc plated. Furnished with locknut. Raintight Available with insulated throat Malleable Iron/Zinc Electroplated UL Listed: E-8 Insulated Throat Trade Size Catalog Catalog Dimensions in Inches (inches) Number Number A B C MF-00 MF-00T MF-0 MF-0T 2 MF-00 MF-00T 2 MF-2 MF-2T 2 MF-0 MF-0T MF-200 MF-200T MF-20 MF-20T 6 MF-00 MF-00T 6 6 Type MF CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB-

14 EA2 Conduit U-Bolts & Hangers Threaded For Rigid Conduit, IMC & EMT EA2 Type U Conduit U-Bolts Dimensions in Inches Trade Size Catalog Thread (inches) Number A B C D Size 2 hex nuts Material: Steel Finish: Mechanically Galvanized U-0SG U-SG 6 2 U-00SG U-2SG 2 6 U-0SG U-200SG U-20SG 4 U-00SG 4 U-0SG Type U 4 U-400SG 4 6 U-00SG 6 6 U-600SG Type H Conduit Hangers Steel/Zinc Plated With Bolt/Nut Dimensions in Inches Trade Size Catalog Clamping (inches) Number A B C Bolt Size - ** H-0WBS 2-20, ** H-WBS , H-2WBS EMT H-2 WBS , - 20, * H-WBS - 20, H-4WBS , 2 H-WBS , 2 H-6WBS , H-WBS , H-8WBS 2 6-8, 4 H-9WBS 6 -, Type H-WBS with clamping bolt **Furnished with carriage bolt

15 EA Beam Clamps EA Type IS Provides support for conduit hanging systems. Material: Malleable Iron clamp Steel Screw, case hardened Finish: Clamp - Hot Dip Galvanized Screw - Zinc Electroplated A B Max. Catalog Tapped Jaw Dimensions in Inches Load Number Holes Opening C D E (lbs.) IS IS IS IS IS Type IS C B - Jaw Opening D A - Tapped Holes (2) Load E

16 EA4 Conduit Clamps EA4 Type UBC Right Angle Type UPC Parallel Type UEC Edge type Designed to secure rigid, IMC or EMT across, parallel or perpendicular to beam, channel and angle supports. Easily installed Capable of withstanding heavy loads Material: All components are Malleable Iron except nuts and bolts which are steel. Finish: Clamp - Hot dipped Galvanized Hardware - Mechanically Galvanized Type UBC-G Type UPC-G Type UEC - G Note: Edge type UEC used for rigid conduit only. Right Parallel Edge Angle Type Type Type Trade Size Catalog Catalog Catalog (inches) Number Number Number UBC-0G UPC-0G UEC-0G UBC-G UPC-G UEC-G UBC-00G UPC-00G UEC-00G UBC-2G UPC-2G UEC-2G UBC-0G UPC-0G UEC-0G 2 UBC-200G UPC-200G UEC-200G 2 UBC-20G UPC-20G UEC-20G UBC-00G UPC-00G UEC-00G UBC-0G UPC-0G 4 UBC-400G UPC-400G UBC-00G 6 UBC-600G

17 EA Pipe Straps For Rigid Conduit & IMC Type 4-S To support rigid conduit and IMC. Snap type - double ribbed Steel/Zinc Plated Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Steel Dimensions in Inches Straps Minimum Trade Size Catalog Recommended (inches) Number A B C Bolt Dia. 4-0S S S S 6 4-0S S S S 6 4-0S S Type 4-S EA Type THR To support rigid conduit and IMC. Snap type - double ribbed Steel/Zinc Plated CSA Certified: 0469 through 2 sizes only CSA C22.2 No.8 Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Steel Dimensions in Inches Straps Minimum Trade Size Catalog Recommended (inches) Number A B C Bolt Dia. THR-0S 2 THR-S THR-00S THR-2S THR-0S THR-200S THR-20S THR-00S THR-0S THR-400S Type THR Type 4-G To support rigid conduit and IMC. Malleable Iron/Hot Dipped Galvanized CSA Certified: 99. CSA: C22.2 No.8 Fed. Spec: FF-S-60 Note: 2 through 4 sizes also suitable for EMT. Malleable Dimensions in Inches Straps Conduit Minimum Catalog Size Recommended Number Inches A B C Bolt Dia. 4-8G 6 4-2G 9 4-8G 4-0G #0 6 4-G G G 6 4-0G G G G G G G G 6 2 Type 4-G

18 EA6 Clamp Backs & Conduit Spacers For Rigid Conduit, IMC & EMT EA6 Clamp Backs Provides spacing from mounting surface when used with malleable iron pipe straps. Material: Malleable Iron Finish: Hot Dip Galvanized Trade Size Catalog Dimensions in Inches (inches) Number A B C D E 4G G 2 4G G G G 2 2 4G 2 48G G x 9 6 x x x 9 x 2 x 6 x x 6 x Clamp Back CSA Certified: G 8 6 G G x 9 2 x x 2 CSA Standard: C22.2 No. 8 Conduit Spacers For use with malleable iron pipe straps and clamp back, to provide additional spacing between conduit and mounting surface. Spacers fit snugly under clamp back and makes possible additional spacing away from the mounting surface. Spacers can stack up into each other so that conduit can be installed at any desired distance from walls or ceilings. Materials: Malleable Iron Finish: Hot Dip or Mechanical Galvanized CSA Certified: 99 CSA Standard: C22.2 No. 8 Trade Size Catalog Dimensions in Inches (inches) Number Length Width Thickness 4-NG NG 2 4-NG NG 4-NG NG NG NG NG NG 8 6 Nest Back Fitting Not included Not included Typical Installation

19 EA Conduit Clamps For Rigid Conduit, IMC & EMT Type J For securing rigid conduit, IMC, EMT and Flexible Metal conduit. Material: Malleable or Ductile Iron Steel Bolt EA Finish: Mechanically Galvanized CSA Certified: 99 CSA Standard: C22.2 No. 8 Type J Zinc Plated Dimensions in Inches Trade Size Catalog (inches) Number A B C D Bolt Size J-0G x J-G x J-00G J-2G J-0G J-200G J J x -6 x -6 x - x - x 2 - x 2 Type CBC Conduit C Clamp For securing rigid conduit, IMC and EMT. Swivel grip rotates a full 60. Malleable Iron/Zinc Plated Steel square head screw Optional Finish: Mechanically Galvanized Contact your local representative for pricing, availability and minimum order quantities. Note: CBC- is maximum beam thickness when using conduit. 2 CBC-2 is maximum beam thickness when using 2 conduit. Trade Size Catalog Dimensions in Inches (inches) Number Length Width CBC CBC-2 4 Swivel Grip Type CBC

20 EA8 Tray-Bond Cable Tray Clamps For Rigid Conduit, IMC & EMT EA8 Type CTC For connecting and grounding rigid conduit, IMC, or EMT to cable trays. Secures and bonds metal conduit (rigid steel or aluminum, IMC and EMT) to the side rails of steel or aluminum cable trays without drilling or welding the tray. On the through 4 sizes, conduits can attach to the tray from any angle up to 20, allowing large power or control cables to be routed easily. Type CTC-00 & Type CTC-02 Sizes Right Angle to Tray Type CTC-0 & Type CTC Sizes Variable Angle to Tray Fast Installation Low Product Cost Excellent Grounding Continuity Variable Conduit Entry - 4 sizes High Mechanical Strength Compact Design Meets NEC 8- (b)(4) Bonding Requirements Suggested Specifications: Raceways connected to cable trays shall be properly bonded using UL Listed and CSA Certified bolted mechanical connectors made from malleable iron, hot dip galvanized components and steel, mechanically galvanized bolts. The cable tray conduit clamps shall be O-Z/Gedney, Type CTC. How Tray-Bond Clamps Work: The edge of the cable tray rail provides the surface on which the serrations in the clamps grounding pad bite into the tray. The lower portion of the clamp has a sharp triangular edge which grabs the underside of the rail. As the U-bolt is tightened, all the force is concentrated in the clamping jaws thus providing an excellent grounding path and high strength mechanical attachment. Malleable Iron/Mechanically Galvanized U-Bolts and Nuts: Steel/Mechanically Galvanized UL Listed: E Rigid or IMC, EMT Dimensions in Inches Recommended Trade Size Catalog U-Bolt & Ins. Torque (inches) Number Nut Size W L T U In. - Lbs. - CTC CTC CTC CTC CTC CTC CTC CTC *Insulated Bushing not included Type CTGC Cable Tray Grounding clamps for use on most types of cable trays. See page MA2. PATENTED CSA Certified: 99 for rigid and EMT only UL Standard: 46 CSA Standard: C22.2 No. 8

21 EA9 Combination Couplings For Rigid Conduit, IMC & EMT EA9 Type ETR Threaded rigid and IMC to compression EMT Concretetight NPT female hub Malleable Iron/Zinc Plated Trade Size Catalog Dimensions in Inches (inches) Number Length Max Dia. ETR-0 ETR- 6 ETR-00 ETR-2 2 ETR ETR UL Listed: E-8 Type ETR UL Standard: 4B Fed. Spec: W-F-408E Type CB Threaded rigid and IMC to flexible metal Rigid hub NPT threads Malleable Iron, Zinc Plated Dimensions in Inches Trade Size Catalog Flex. (inches) Number Length Max Dia. Range CB-0 CB CB UL Listed: E-8 Type CB CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E Type ESR Concretetight Set screw Threadless rigid and IMC to EMT Trade Size Catalog Dimensions in Inches (inches) Number A B C ESR ESR- 2 6 ESR Malleable Iron/Zinc Plated UL Listed: E-8 Type ESR UL Standard: 4B Fed. Spec: W-F-408E

22 EA20 Concrete Slab Electroform Inserts For Threaded Rigid Conduit & IMC EA20 Type EF & Type EFL For conduit installed in poured concrete slabs. Nail, screw or tack-weld insert to concrete deck form. Inserts available in straight or 90 Malleable Iron/Zinc Plated UL Listed: E-8 CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 Fed. Spec: W-F-408E Type EF-0 Type EF-00 For concrete slab 4 thick and up. STRAIGHT CONDUIT INSERTS Dimensions in Inches Base Trade Size Catalog Base Across (inches) Number Dia. Flats Height Type EFL-0 Type EFL-00 For slabs 6 thick and up require bend conduit sweep. EF EF EF CONDUIT INSERTS Dimensions in Inches Base to Trade Size Catalog Base Turning Conduit (inches) Number Dia. Radius Center Height EFL-0 6 EFL EFL Shown in poured concrete slabs before wood or steel forms are removed.

23 EB Watertight Hubs Die Cast, Insulated and Gasketed EB Used in applications to connect rigid metal conduit or IMC to a threadless opening in an enclosure. May be used in wet or dry locations, indoors or outdoors. Suitable for hazardous locations: Class I, Division 2; Class II, Divisions & 2; Class III, Per NEC 0.4(B), 02.4(A) & (B), 0.(A) & (B). Rugged metallic construction ensures mechanical protection. Die cast design provides clean lines and aesthetic appeal. Insulated throat, rated up to 0 C, prevents wire abrasion. Integral O-ring provides watertight seal. Grounding version provides positive ground for external conductor. Unique profile permits easy wrenching. Smooth, accurately tapped threads facilitate installation. Watertight and corrosion resistant: NEMA 4X. NEMA 2. Material: Bodies and nuts: Die Cast Zinc O-ring: BUNA-N Insulator: Polycarbonate Ground Screw: Mild Steel Size Ranges: /2" through 4" CHM CHMG Optional Finishes: Chrome plating optional add suffix C. UL Listed UL Standard 4B CSA Certified (incl. Class II, Groups E, F, G) CSA Standard C NEMA Type 2,, R, 4, 4X,, 2, NEMA Standard FB- O-Z/Gedney UL File No. E8 O-Z/Gedney CSA File No. LR99

24 EB2 Watertight Hubs Die Cast, Insulated and Gasketed EB2 B A G H D C F E CHM Series CHMG Series Die Cast Hubs Insulated (All dimensions are in inches.) Panel Catalog Trade Hole Dia. Thickness Dimensions Number* Size Min. Max. Min. Max. A B C CHM-0DT / CHM-DT / CHM-00DT CHM-2DT -/ CHM-0DT -/ CHM-200DT CHM-20DT 2-/ CHM-00DT CHM-0DT -/ CHM-400DT * For chrome plating, add suffix C. Grounding Style Hubs Insulated (All dimensions are in inches.) Panel Catalog Trade Hole Dia. Thickness Dimensions Number* Size Min. Max. Min. Max. D E F G H CHMG-0DT / X/ CHMG-DT / X/4 0.8 CHMG-00DT X/4 0.8 CHMG-2DT -/ /4-20X/8 0.8 CHMG-0DT -/ /4-20X/8.00 CHMG-200DT /4-20X/2.00 CHMG-20DT 2-/ /4-20X/2.2 CHMG-00DT /4-20X/2.2 CHMG-0DT -/ /4-20X/2. CHMG-400DT /4-20X/2. * For chrome plating, add suffix C.

25 EB Watertight Hubs Grounding Nuts and Hub Spacing Chart EB L I K J CHML Series Grounding Nuts (All dimensions are in inches.) Catalog Trade Wire Size Wire Size Dimensions Number* Size Min Max I J K L CHML-0D /2" #4 stranded #0 stranded x/4 CHML-D /4" #4 stranded #0 stranded x/4 CHML-00D " #4 stranded #0 stranded x/4 CHML-2D -/4" #0 solid #6 stranded /4 20x/8 CHML-0D -/2" #0 solid #6 stranded /4 20x/8 CHML-200D 2" #0 solid #6 stranded /4 20x/2 CHML-20D 2-/2" #0 solid #6 stranded /4 20x/2 CHML-00D " #0 solid #6 stranded /4 20x/2 CHML-0D -/2" #0 solid #6 stranded /4 20x/2 CHML-400D 4" #0 solid #6 stranded /4 20x/2 * For chrome plating, add suffix C. Hub Spacing Chart (All dimensions are in inches.) Knockout Trade Hole Size Size /2" /4" " -/4" -/2" 2" 2-/2" " -/2" 4" /8" /2".6 -/8" /4" /8" " /4" -/4" " -/2" /2" 2" " 2-/2" /8" " /8" -/2" /8" 4" Dimensions in bold are for centers of conduits of same size, all other dimensions are for centers of conduits of a different size. Minimum spacing dimensions as shown above will give approximately /8" clearance between the lock nuts.

26 Notes

RACO Commercial Fittings

RACO Commercial Fittings RACO Commercial Fittings B2 GENERAL INFORMATION - STANDARDS, 1999 NATIONAL ELECTRICAL CODE General Information When you need to couple, connect, fasten, or ground conduit or cables, RACO fittings are your

More information

Ground Clamps Cable Tray

Ground Clamps Cable Tray commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and

More information

RACO Commercial Fittings

RACO Commercial Fittings 06 Pg B1 - B20.qxp 6/9/2008 9:47 AM Page B1 RACO Commercial Fittings 06 Pg B1 - B20.qxp 6/9/2008 9:47 AM Page B2 B2 dbkbo^i=fkcloj^qflk=j=pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab déåéê~ä=fåñçêã~íáçå tüéå=óçì=åééç=íç=åçìéäéi=åçååéåíi

More information

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features

commercial and industrial fittings: cast DEVICE BOXES Applications Illustrated Features UNILETS for use with Threaded Rigid Conduit and IMC. All Device Boxes have Construction. Furnished with Internal Ground Screw. Applications Accommodate wiring devices such as switches and receptacles.

More information

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project

BELL. RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project SOLAR RACO, TayMac and BELL offer a full line of electrical products that are ideally suited to help you complete your next solar project Commercial, Industrial and Residential Electrical Products RACO

More information

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End;

Description Cast Device Box, Height Inch; Width 2.81 Inch; Depth 2.69 Inch; Capacity 25 Cu Inch; 1 Gang; 2 Hub(S); Hub Location End; 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 1100 1G Mall Box Appleton/Oz Gedney Catalog Number 1100 Manufacturer Appleton/Oz Gedney Description Cast Device Box, Height

More information

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications

COMMERCIAL AND INDUSTRIAL FITTINGS: CAST DEVICE BOXES. Applications Blank Bodies for Brazed Hubs UNILETS for Use with Threaded Rigid Metal Conduit and IMC. Available with Hub Sizes from 1/2 through 1-1/2 (Union 1/2 through 1-1/4 ). Furnished with Internal Ground Screw.

More information

General Information...SA1-SA4

General Information...SA1-SA4 SECTION S INDEX Product Description Page Number General Information................................................................SA1-SA4 Type FSK Thruwall & Floor Seal For Conduit, Pipe or Tubing............................

More information

Thru Wall Floor Seals For New Installation

Thru Wall Floor Seals For New Installation The O-Z/Gedney Thruwall and Floor Seals provide a positive means of sealing pipe, conduit or tube where they pass through a concrete foundation of a structure below grade or below ground water level or

More information

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT

SECTION WIREWAYS FOR RADIOLOGY EQUIPMENT PART 1 - GENERAL 1.1 DESCRIPTION SECTION 26 05 36 WIREWAYS FOR RADIOLOGY EQUIPMENT SPEC WRITER NOTE: Delete between //----// if not applicable to project. Also, delete any other item or paragraph not applicable

More information

FSK1VDRA 1G Al DPLX RCPT CVR

FSK1VDRA 1G Al DPLX RCPT CVR 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FSK1VDRA 1G Al DPLX RCPT CVR Appleton/Oz Gedney Catalog Number Manufacturer Weight per unit Product Category FSK1VDRA

More information

Beam and Purlin Clamps Beam Clamps

Beam and Purlin Clamps Beam Clamps Metal Framing & Cable Tray Steel City Hangers, Clamps & Fasteners Beam and Purlin Clamps Beam Clamps Fits beam flanges to 2" Supports 4" and 8" threaded rod, S-hooks, electrical boxes, conduit and bridle

More information

tings fi t fl ex/mc/ac

tings fi t fl ex/mc/ac 22 flex/mc/ac fittings Nothing can be more frustrating than losing valuable time due to low quality fittings. Madison s Flex/AC/ MC fittings come through for you time after time. Giving you affordability

More information

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Wrenches. Wrenches. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1 F o r P r o f e Klein s line of wrenches are forged from the finest steel and are designed to deliver great strength, and long working life. Regardless of the job type, Klein has a wrench that will help

More information

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers

Copper Tubing Hangers Clevis Hangers. Copper Tubing Hangers Copper Tubing Hangers Clevis Hangers Copper Tubing Hangers Fig. CT-69 Adjustable Swivel Rug Fig. CT-138R Fig. CT-65 Fig. CT-109 Extension Split Light Weight Adjustable Clevis Fig. CT-99 & CT-99C Split

More information

Ford Water Meter Couplings & Accessories

Ford Water Meter Couplings & Accessories Section H 2/2001 Ford Water Meter Couplings & Accessories The Ford Meter Box Co., Inc. 775 Manchester Avenue, P.O. Box 443, Wabash, Indiana, USA 46992-0443 Telephone: 260/563-3171 FAX: 1-800-826-3487 Overseas

More information

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life.

Available in high-capacity. and assembled by hand for smooth operation. Durable chrome-plated finish. Heat-treated for long life. Klein s line of wrenches are forged from the finest steel and are designed to deliver great strength and long working life. Regardless of the job type, Klein has a wrench that will help the professional

More information

E.M.T. Set-Screw Connectors. Technical Specifications

E.M.T. Set-Screw Connectors. Technical Specifications Set-Screw onnectors Regular Insulated I5404 (-IT) / I5408 (-IT) Steel Locknut I5004 (-IT) / I5008 (-IT) I5020 (-IT) / I5032 (-IT) I5410 (-IT) / I5432 (-IT) Steel Locknut I5010 (-IT) / I5016 (-IT) I5054

More information

PIPE/CONDUIT SUPPORTS

PIPE/CONDUIT SUPPORTS PIPE/CONDUIT SUPPORTS Pipe/Conduit Clamps...102-105 Unicushion... 106 Pipe & Tubing (Cush-A-Clamp ) Clamps...107-110 Pipe Hangers... 111 Pipe Rollers...111-112 Pipe Brackets... 113 Reference Tables...114-120

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable

Zinc Cable & Conduit Connectors For Armored Cable, Flexible Metal Conduit & Metal Clad Cable For Armored Cable, Flexible Metal Conduit & Metal Clad Cable Type AC 90 2-Screw Clamp To make a 90 termination of conduit or cable to a knockout or unthreaded slip hole in a dry location box or enclosure.

More information

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT)

Iberville. Commercial Grade Fittings EMT CI5410 / CI5432 CI5410IT / CI5432IT CI5404 / CI5408 CI5404IT / CI5408IT CI5004 (-IT) / CI5008 (-IT) ommercial Grade Fittings Set-Screw Fittings I5404 / I5408 I5404IT / I5408IT I5004 (-IT) / I5008 (-IT) I5410 / I5432 I5410IT / I5432IT I5010 (-IT) / I5016 (-IT) Regular Insulated Set-Screw Fittings (Steel)

More information

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG

Waterpipe Ground Clamps. 1/2 in., 3/4 in., 1 or rebar /4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 AWG Waterpipe Ground Ground Wire Size Water Pipe Size 2-T 1/2 in., 3/4 in., 1 or rebar 4-10 3-T 1-1/4 in., 1-1/2 in. or 2 in. 4 #6, #4, #2 WG 2-1/2 in., 3 in. or 3-1/2 in. 5-T 4 in., 4-1/2 in. or 5 in. 6 6

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

Cast Iron Junction Boxes

Cast Iron Junction Boxes Cast Iron I. Purpose of Enclosure Enclosures are used to protect personnel against accidental contact with enclosed electrical devices or connections and to protect the enclosed devices or connections

More information

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials

Superstrut. Metal Framing. Beam Clamps. Design Loads. Finishes and Special Materials Loads Where design loads are indicated, they provide for a safety factor of 3 in conformance with the merican Standard Code for Pressure Piping. For more information, see page 57 for Engineering Data and

More information

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes

05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A75 RACO Floor Boxes 05 Pg A75-90.qxp 6/9/2008 9:36 AM Page A76 A76 pq^ka^oapi=ommu=k^qflk^i=bib`qof`^i=`lab Δ déåéê~ä=^ééäáå~íáçåë o^`l=ñäççê=äçñéë=~êé=áçé~ääó=ëìáíéç

More information

Tel / (USA & CANADA) /

Tel / (USA & CANADA) / Tel.58.847 / 8.388.459 (USA & CANADA) / Email sales@msdiscounttool.com MULTIPURPOSE CLAMPS - USA SERIES 7: Lightweight and 4% stronger than C clamps. Floating jaws that always stay parallel. Designed to

More information

INTERMEDIATE METAL CONDUIT

INTERMEDIATE METAL CONDUIT PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS

More information

ASAP Sr. A Strap and Pole. Magic Christmas. Single Stage. Walter Monkhouse. Alexandria, La. Version 1.2.

ASAP Sr. A Strap and Pole. Magic Christmas. Single Stage. Walter Monkhouse. Alexandria, La. Version 1.2. ASAP Sr Single Stage A Strap and Pole Version 1.2 Walter Monkhouse Walter@MagicChristmas.org Magic Christmas Alexandria, La. Description The ASAP Sr, single stage, has the same concept as the ASAP Jr.

More information

Index Pipe Hangers and Straps

Index Pipe Hangers and Straps Index Pipe Hangers and Straps Fig. 1 Standard Clevis Hanger MSS-SP-69, Type 1 WW-H-171E, Type 1 Page 14 Fig. 1CI Clevis Hanger for A.W.W.A. Page 16 Fig. 81 Clevis Hanger WW-H-171E, Type 12 Page 70 Fig.

More information

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box Concealed Service Floor Boxes 663 Series Floor Box 663-SC Multiple service floor box that delivers power, communications and data from standard conduit with no exposed service fitting Result: Open office

More information

Product #: Product #:

Product #: Product #: STANLEY FATMAX Push-Lock Groove Joint Pliers Multi-purpose jaws designed to grasp flat and round objects. Push-Lock technology allows for quick and easy adjustment in 17 positions. Induction hardened jaws

More information

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY

Steel City Comparison & Strategy. vs. T&B Liquidtight Fittings. Andrea Briggs. Associate Product Manager - Conduit & Fittings FOR INTERNAL USE ONLY Comparison & Strategy Andrea Briggs Associate Product Manager - Conduit & Fittings Liquidtight Fitting Brand Strategy Component Comparisons Summary Liquidtight Fitting Brand Strategy Steel City Liquidtight

More information

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

5/16 Flange nut. Bolt Keeper Plate (8 Sq. SYS.) (3) 1/2 x 3 Hex head connector zinc plated bolt w/ washers and nut. Anchor 3 sq. 7 Ga. 2 1/2" x 2 1/2" x 10 Ga. 6" 5" 4" Variable Slipbase (8" Sq. SYS.) 5/16 Corner Bolt W/ nut 5/16" Flange nut Stub Insert (8" Sq. SYS.) Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc

More information

STAR TOOL SUPPLY / GRAND TOOL SUPPLY

STAR TOOL SUPPLY / GRAND TOOL SUPPLY MULTIPURPOSE CLAMPS - USA SERIES 7: Lightweight and 4% stronger than C clamps. Floating jaws that always stay parallel. Designed to eliminate distorting or twisting action. Cantilever action provides 4:

More information

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval

TRANSMITTAL LETTER. As Builts Change Order Contract Copy of Letter Insurance. For approval Approved as submitted Resubmit copies for approval Redwood City Electric, Inc. TRANSMITTAL LETTER To: Transworld Construction, Inc. 1178 Folsom Street San Francisco, CA 94103 Date: 05/31/12 Job #: 9340 Regarding: SFO DATA CENTER Attn: Rob Acero We are

More information

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth STRENGTH Diamond serrated jaws provide a firm grip PLIERS AND SNIPS Locking Pliers Slip Joint Pliers Electrician s Pliers

More information

Assembly Instructions

Assembly Instructions InTandem Table System November 20 InTandem Table System - Worksurface #4 x/" 4 wood screw power beam Tools Provided T-0 Extended Torx Driver T-25 Torx Driver Additional Tools Required Soft protective

More information

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover.

AGUB Instrument and Meter Enclosures Explosionproof, Dust-Ignitionproof Furnished with aluminum body and solid or window cover. AGUB Instrument and Meter Enclosures Furnished with aluminum body and solid or window cover. Class I, Division 1 and, Groups B, C, D Application To pull or splice wires and/or to mount and enclose electrical

More information

Modular Gazebo Kit Series GardenHouse 12

Modular Gazebo Kit Series GardenHouse 12 Octagonal CUPOLA screened with louvers and light fixture Modular Gazebo Kit Series GardenHouse 12 with DOUBLE-TIERED Roof Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or

More information

Dura-Lock Roof System

Dura-Lock Roof System DLR-14 Dura-Lock Roof System Assembly and Installation Instructions Read the instructions before starting the job. They explain the steps required to produce a finished product that will meet factory specifications.

More information

FIRE PROTECTION PRODUCTS

FIRE PROTECTION PRODUCTS FEATURES Rev. 7-11 Mueller Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also,

More information

NORMATIVE REFERENCES

NORMATIVE REFERENCES American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and

More information

Product Guide Specification

Product Guide Specification Zurn Industries, LLC November 2014 1801 Pittsburgh Avenue Erie, PA 16502 Toll Free (855) 663-9876 Phone (814) 455-0921 Fax (814) 871-6141 Website www.zurn.com Product Guide Specification Specifier Notes:

More information

AUXILIARY FRAMING AND ACCESSORIES

AUXILIARY FRAMING AND ACCESSORIES CUSTOM CABINETS & RACKS STRUT AND ACCESSO- RIES JUNCTION KITS ANGLE AND BRACE KITS SPLICE KITS BRACE KITS INSTALLATION KITS WALL ANGLE KITS RUBBER END CAPS SUPPORT INSTALLATION AND SUPPORT KITS STANCHION

More information

Superstrut Stainless Steel Channels and Accessories

Superstrut Stainless Steel Channels and Accessories In this section... Superstrut Stainless Steel Channels and Accessories Superstrut Stainless Steel Channels and Accessories Channels...46 Channel Fittings and Hardware...47 49 Clamps and Hangers...50 52

More information

NORMATIVE REFERENCES

NORMATIVE REFERENCES American National Standards Institute NORMATIVE REFERENCES ANSI C135.30 1988 (expired 1993) Zinc-Coated Ferrous Ground Rod Electrodes for Overhead or Underground Lines American Society for Testing and

More information

OXYGEN INSTALLATION. Revision date

OXYGEN INSTALLATION. Revision date 12345 1 Hardware List 12345 Flat head wood screw #9 x 7/8 long with #2 Phillips drive, silver Used to attach surfaces and end panels Hex set screw ½-13 x 2 long with 1/4 hex drive, black Used on Legs Hex

More information

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS SECTION 270536 - CABLE TRAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

Assembly Instructions 10 X 10 Aluminum Frame Building

Assembly Instructions 10 X 10 Aluminum Frame Building Assembly Instructions 10 X 10 Aluminum Frame Building 27 97 9 8 47 36 74 52 10 10 X 10 Square Building W/ Dome Includes: The Steel Entry Door with a Dead Bolt Lock assembly and Aluminum Door Frame. Metal

More information

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains.

WADE 2-1. Universal Carrier. Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains. Universal Carrier Exclusive Features of 400 Series Universal Carrier for Lavatories, Urinals, Drinking Fountains. The 400 series carrier accommodates most urinal, water-cooler or hanger plate lavatory

More information

DETAILED ILLUSTRATION

DETAILED ILLUSTRATION FCF1100 Series (Mounting Knuckle to J-Box JB) - INSTALLATION INSTRUCTIONS electricity has been turned off and electrical 4) Reattach j-box cover, gasket and fixture to the j-box. to read these instructions

More information

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized

Cat. No. A1200 A1200-S A1200-KO. Finishes & Materials. E142-1/4x100EG 1/4 x 1 A100-5/16EGC A100-3/8EGC. Standard Finish: Electrogalvanized Superstrut Support Systems 1-5/8 in. x 1-5/8 in. Channel and Hardware Superstrut 1-5/8 in. x 1-5/8 in. - 12 Gauge Channel Type A Solid Base Punched Description Solid base -P Punched -HS Half slots Half

More information

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to "ORDER LENGTH" codes B through F; code A has 22" adjustment.

UL / FM E-1 FIRE PROTECTION PRODUCTS INDICATOR POST FEATURES. *Applies to ORDER LENGTH codes B through F; code A has 22 adjustment. UL / FM MUELLER Indicator Post are used in fire protection systems and perform several functions. The Indicator Post provides a means to operate a buried or otherwise inaccessible valve. Also, the Indicator

More information

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub

Tuf-Lite II Fans H Hi Temp 3000HT Series Hub Tuf-Lite II Fans H Hi Temp 3000HT Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II Hi Temp Fan Blades Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Hi Temp fan blades (Red) are

More information

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit

NEER Zinc Cable and Conduit Connectors For Flexible Metal Conduit For Flexible Metal Conduit SC: Straight Squeeze Type Connector These squeeze type connectors are used to terminate flexible metal conduit to a 1/2 knockout in a dry location box or enclosure. 1/2" and

More information

SWAY BRACE PIPE ATTACHMENT FIG. 010

SWAY BRACE PIPE ATTACHMENT FIG. 010 Function: Designed for bracing pipe against sway and seismic disturbance. The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting,

More information

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM

INSIDE PANEL NOT SHOWN TO DETAIL ANCHORING SYSTEM SIX INCH ALPHA MODULE INSTALLATION KEWAUNEE SCIENTIFIC CORPORATION SIX INCH ALPHA MODULE ANCHORING SYSTEM After Alpha module has been set in desired location. Adjust the four adjustment bolts until the

More information

Leveling Feet, Base Plates and Casters

Leveling Feet, Base Plates and Casters Leveling Feet, Base Plates and Casters 77 Leveling Foot 1 1 Fastening to profile end Fastening in T-slot of profile For leveling tables and light equipment. Ratchet-type height adjustment requires no tools.

More information

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength

Fastener Basics. Common Fastener Types. Fastener Materials. Grade / Class and Fastener Strength Fastener Basics Common Fastener Types Fastener Grade (US) or Class (metric) refers to the mechanical properties of the fastener material. Generally, a higher number indicates a stronger, more hardened

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JUN15 MOUNT INSTALLATION GUIDE PUB5JUN5 Wrenches and Torque SM SOLAR Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug

content Introduction Some good reasons to use SMARTr products Reducers, Plugs Conduit Reducer Stopping Plug CONTENT 1 2 Introduction Some good reasons to use SMARTr products G.I. CONDUITS SMARTr BS4568 : PT1 : 1970 Class 4, IEC 61386-21 : 2004 IEC60614-2 - 1 : 1993, BS EN 50086-2 -1 : 1996 SMARTr BS4568 : PT1

More information

Hose Accessories. "Air King" 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End

Hose Accessories. Air King 4 - Lug Quick-Acting Couplings. Hose End. Female N.P.T. End "Air King" 4 - Lug Quick-Acting 1¼" 1½" AM16 AM AM6 AB16~ AB~ AB6 End Rubber Washers for 4-Lug AWR14 Fits all sizes 1¼" 1½" AM18 AM3 AM8 AB18~ AB3 AB8 Rated to 1 PSI Female N.P.T. End "Boss" clamps recommended

More information

STEVENS SUBPLATES. STEVENS ENGINEERING, INC. TOLL-FREE WEB FAX

STEVENS SUBPLATES. STEVENS ENGINEERING, INC. TOLL-FREE WEB   FAX STEVENS SUBPLATES Spacing of hole patterns on Stevens accessories is identical to the pattern on Stevens Subplates. Insertion of the pull dowels thru bushed holes in the accessory into corresponding bushed

More information

Tuf-Lite III Fans 3000K Series Hub

Tuf-Lite III Fans 3000K Series Hub Tuf-Lite III Fans 3000K Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01

INSTALLATION GUIDE SM SOLAR MOUNT PUB15JAN01 MOUNT INSTALLATION GUIDE PUB5JAN0 SM SOLAR Wrenches and Torque Wrench Size Recommended Torque (ft-lbs) /4 Hardware 7/6 *0 3/8 Hardware 9/6 *30 # Hardware 5/6 0 Torques are not designed for use with wood

More information

Rayport G Eco Dealer Kit

Rayport G Eco Dealer Kit Rayport G Eco Dealer Kit Installation Guide www.aetenergy.com Supporting a Cleaner, Greener Tomorrow 1. Table of Contents 1. Table of Contents P2 2. Installer Notes P3 3. Parts List P4-7 4. Tool List P8

More information

Optical Cable Entry Facility (OCEF) Installation Instructions

Optical Cable Entry Facility (OCEF) Installation Instructions Instruction Sheet 860380690 Uniprise Solutions Optical Cable Entry Facility (OCEF) Installation Instructions General The Optical Cable Entry Facility (OCEF) cabinets store optical fiber splices between

More information

Clearview Railing System Installation Instructions

Clearview Railing System Installation Instructions Clearview Railing System Installation Instructions Disclaimer: AGS Stainless, Inc. has its Clearview Railing Systems designed by a professional engineer to meet the requirements of the latest national

More information

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105

BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105 BBF Series Blower Base Frame Assembly Instructions Rev.: BFA-9105 These assembly instructions are to be used as a general reference guide to facilitate assembly. Please consult the blower, bushing, sheave,

More information

Type XTSR71 Sizes

Type XTSR71 Sizes (Page 1 of 13) s 494-5258 Type XTSR71 s 494-5258 Figure 1 Thomas XTSR71 Coupling 1. General Information 1.1 Thomas Couplings are designed to provide a mechanical connection between the rotating shafts

More information

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM )

Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) Liquid Tight Conduit Connector With Internal Threads, Female Liquid Tight Conduit Fittings ( YCM ) No. Trade Dimensions (mm) Size I.D. A B C Threads YCM-03 3/8 11.2 28.3 44.6 13.2 PT 1/2 YCM-04 1/2 14.8

More information

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance.

Delikon Stainless Steel Liquidtight Connectors offer corrosion resistance and the strength of stainless steel for the highest levels of endurance. Corrosion Resistant liquid tight conduit fittings for use with flexible liquid tight metallic conduits, flexible liquid tight non metallic or PVC coated flexible metal conduit. * Liquidtight, Raintight,

More information

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS

International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS International Tube & Conduit Company Ltd. BRITISH STANDARD STEEL CONDUITS & FITTINGS 1 ABOUT THE COMPANY VISION STATEMENT We strive to exceed our customers expectations through leading edge technologies

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. blue**) fan blades are made from

More information

CONTINUING EDUC ATION

CONTINUING EDUC ATION 3 CONTINUING EDUC ATION FOR WISCONSIN ELECTRICIANS 2017 NEC Article 250 2 Hours WISCONSIN CONTRACTORS INSTITUTE N16 W23217 Stone Ridge Drive Suite 290 Waukesha, WI 53188 262-409-4282 www.wcitraining.com

More information

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub

Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub Tuf-Lite III Fans K Hi Temp 3000KHT Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 11 thru 15 Diameter Hudson Tuf-Lite III fan blades Hudson Tuf-Lite III Hi Temp (Red) fan blades are of single

More information

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger

INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger INSTALLATION INSTRUCTIONS FOR FRONT CASTING DECK RAIL Ranger TOOLS REQUIRED FOR INSTALLATION: Drill motor, (1) 5/16 inch drill bit, (1) 13/64 drill bit, (1) 3/16 inch hex wrench (1) 3/32 inch hex wrench.

More information

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW

CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD METAL SCREWS. 6 x 3/4 P/N x 1 METAL SCREW P/N x 3/4 METAL SCREW A21-1 1160 CIC 200 PLASTIC SCREW ANCHOR ASSORTMENT WITH PHILLIPS BINDING HEAD S For light duty applications in solid materials Color coded diameters for easy identifi cation Acid resistant NYLON FLANGED:

More information

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub

Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub Tuf-Lite and Tuf-Lite II Fans 4000 Series Hub INSTALLATION MANUAL Hudson Tuf-Lite and Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 15 thru 20 Diameter Hudson Tuf-Lite (black) fan blades are made

More information

TOOLS AND INSTALLATION

TOOLS AND INSTALLATION TOOLS AND INSTALLATION Safe, leak-free operation of any high-pressure system is dependent on correctly prepared and installed connections. This section outlines proper instructions for the machining and

More information

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit

2/15/2015. Current will always try to return to its source. In order for there to be current, there must be a complete circuit Current will always try to return to its source In order for there to be current, there must be a complete circuit Current will take as many paths or circuits available to it to return to the source The

More information

Factory Assistance: Phone: Fax: Page 1

Factory Assistance: Phone: Fax: Page 1 CABLE RUNWAY ACCESSORIES Radius Drop / Stringer Drop Provides 3 bend radius Radius drop fits 6, 12 and 18 runway made from 1-1/2 x 3/8 tubing Steel construction Includes (3) cable spools, (1) bolt, (1)

More information

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6

Rigid PVC Conduit Fittings Injection Molded in Sizes 1/2-6 Rigid PVC Conduit Fittings Injection Molded in Sizes / - E Royal Building Products offers a complete line of rigid PVC conduit fittings. Royal s non-metallic conduit and fittings are certified by the CSA

More information

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below. Bulletin H Product verview/specifications Bulletin H/ Hazardous locations push buttons and stations Classes I, II & III Divisions & / in. - NPSM barrel Type & Explosion-proof operators Table of Contents

More information

C-Clamps and Lifting Eyes (Eye Bolts)

C-Clamps and Lifting Eyes (Eye Bolts) 0-C-Clamps & Lifting Eyes-R 2/21/08 9:42 PM Page 1 C-Clamps A B C Armstrong C-Clamps When your requirements call for clamps, specify Armstrong the most accepted name in the business. When you see Armstrong

More information

SolarMount (E)volution

SolarMount (E)volution SolarMount (E)volution SOLARMOUNT (E)VOLUTION: THE BEST JUST GOT BETTER. Engineering, Excellence, and Ease. Performance Engineered for versatility and reduced installation time, SolarMount (E)volution

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)...

INS A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE. 1. Unpacking the KSCR Splicing the KSCR (If Required)... INS-88.500-0A KSCR INSTALLATION INSTRUCTIONS STANDARD PROCEDURE 1. Unpacking the KSCR... 2 2. Splicing the KSCR (If Required)... 4 3. Assemble Curb and Rail Corners... 5 4. Install Cross Bracing (If Required)...

More information

Tuf-Lite III Fans 5000K Series Hub

Tuf-Lite III Fans 5000K Series Hub Tuf-Lite III Fans 5000K Series Hub INSTALLATION MANUAL Hudson Tuf-Lite III fan blades Adjustable Pitch Fan Assembly 20 thru 30 Diameter Hudson Tuf-Lite III fan blades are of single piece fiberglass reinforced

More information

Tuf-Lite II Fans 3000H Series Hub

Tuf-Lite II Fans 3000H Series Hub Tuf-Lite II Fans 3000H Series Hub INSTALLATION MANUAL Adjustable Pitch Fan Assembly 5 through 14 Diameter Hudson Tuf-Lite II Fan Blades Hudson Tuf-Lite II (white, prev. Blue**) are made from fiberglass

More information

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

MM540 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS MM50 Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS Please read this entire manual before you begin. Do not unpack any contents until you verify all requirements on PAGE.

More information

THE ROGUE TM FUNSLIDE TM

THE ROGUE TM FUNSLIDE TM THE ROGUE TM FUNSLIDE TM ASSEMBLY AND INSTALLATION INSTRUCTIONS * * C A U T I O N * * S.R. SMITH ROGUE TM FUNSLIDES TM ARE MANUFACTURED FOR INSTALLATION AND USE ON RESIDENTIAL INGROUND POOLS ONLY. ROGUE

More information

GLOSSARY OF TERMS SECTION 8

GLOSSARY OF TERMS SECTION 8 GLOSSARY OF TERMS SECTION 8 Anchor Bolt Angle Base Plate Bay Blocking CCB Centerline Chord Cladding Clip Closure Strip An A-307 steel bolt embedded in the concrete footing to anchor the base plate of the

More information

STEEL C-CLAMP WITH LOCKNUT

STEEL C-CLAMP WITH LOCKNUT FIG. 250 STEEL C-CLAMP WITH LOCKNUT Function: Designed for attaching hanger rod to the bottom flange of a beam. The hanger rod should make contact with the beam flange to ensure full engagement. Material:

More information

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe

Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe Stargrip series 3000 Mechanical Joint Wedge Action Restraint for Ductile Iron Pipe INFORMATION The Stargrip Mechanical Joint Restraint System is a unique product with a proven design that provides an exceptional

More information

Tuf-Lite II Fans 3000HC Series Hub

Tuf-Lite II Fans 3000HC Series Hub Tuf-Lite II Fans 3000HC Series Hub INSTALLATION MANUAL Hudson Tuf-Lite II fan blades Adjustable Pitch Fan Assembly 8 through 10 Diameter Hudson Tuf-Lite II (White) are made from fiberglass reinforced vinyl-ester

More information

ALUMINUM PIPE GUIDERAIL 01/01/

ALUMINUM PIPE GUIDERAIL 01/01/ NOTES PIPE RAILING & POSTS: Structural Tube, Pipe and Bar shall be in accordance with ASTM B22 or ASTM B429, Alloy 606-T6. End Rail 90 bends and corner bends with maximum 4-0" post spacing, may be Alloy

More information