GENERAL AIR OPERATED SPECIFICATIONS PILOT OPERATED SPECIFICATIONS. Series /8 = 3000 l/min 1/2 = 3800 l/min

Size: px
Start display at page:

Download "GENERAL AIR OPERATED SPECIFICATIONS PILOT OPERATED SPECIFICATIONS. Series /8 = 3000 l/min 1/2 = 3800 l/min"

Transcription

1 SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, /4 to / 0 / 0 Series FTURS The monostable spool valves, series 55, have TÜV certifi ed I 650 Functional Safety data and can be used up to SIL 4/K 7 The spool valves / N have threaded port connections ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) poxy moulded coil for general service applications The solenoid valves satisfy all relevant irectives GNRL ifferential pressure Flow (Qv at 6 bar) - 0 bar [ bar = 00 kpa] /4 = 60 l/min (NR) / = 000 l/min / = 00 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered - 5 to + 60 NR (nitrile) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody luminium, black anodised nd covers Glass-fi lled P Internal parts Zamak, stainless steel, POM, aluminium Seals NR + PUR ore and plugnut Stainless steel Shading coil opper IR OPRT SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) prefix option basic catalogue number min. air ( ) ( ) (mm) (m /h) (l/min) ~ = ir pilot operated - spring return (monostable) /4 6 0,75, () /,4 4, /,5 5, ir pilot operated and return (bistable) /4 6 0,75, /,4 4, /,5 5, UP Not available Ultra Low LP RP-MP P Not available,5w - 4W 6,W Low Reduced and Medium asic POWR LVLS - cold electrical holding values (watt) PILOT OPRT SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) max. (PS) level prefix optional solenoids basic catalogue number TX/NL (gas/dust) IP65 min. air ( ) x d x em x m x i ( ) (mm) (m /h) (l/min) ~ = ~/= PV S Solenoid air pilot operated - spring return (monostable) /4 6 0,75,5 0 0 RP () /4 6 0,75,5 0 0 MP () /,4 4,5 0 0 P /,5 5,5 0 0 P Solenoid air pilot operated and return (bistable) /4 6 0,75,5 0 0 RP /4 6 0,75,5 0 0 MP /,4 4,5 0 0 P /,5 5,5 0 0 P Select for NPT NSI.0. or select G for ISO G (/) vailable feature - Not available () ertifi ed I 650 Functional Safety data, use suffi x "SL". ll leafl ets are available on: 007/R0 第 /0 页 PI-4-40-G

2 SRIS PRFIX TL prefi x level description LP RP MP P S U ustproof TX (N 50--) * - - P V ncapsulated TX (N 500) * - - S Solenoid with spade plug connector (N 6070) - - X Other special constructions - - SUFFIX TL suffi x level description 4 5 LP RP MP P G Non-electrical, G c, construction safety, gas/dust-tx (N 46-5) M S Screw type manual operator - S L ertifi ed I 650 Functional Safety data () - vailable feature - Not available * TX solenoids are also approved to N 50-- (dust) and N 46- (non electrical valves) () Not to use with MS suffi x PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations table on page. xample : G55005 STP Select prefi x (combination). Select the appropriate operator from the specifi cations table on page and the prefi x table on page. Select for this operator in the electrical characteristics table on page : the level (RP, MP, P), the type of electrical enclosure protection and the desired temperature class. The air operated version is without prefi x. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. o not use prefi xes for air operated versions. xample : PV STP Select suffi x (combination) if required. Suffi x G only applies for the air operated versions, do not use suffi x MS. xample : MS STP 4 Select voltage. Refer to standard voltages on page. xample : 0V / 50Hz STP 5 Final catalogue / ordering number. xample : PV G55005MS 0 V / 50 Hz OPTIONS & SSORIS series pipe exhaust protector (stainless steel) (G) (NPT) (M) 55 / () () - 55 / / /55/ () () Provided with "SL" suffi x. ORRING XMPLS: S G MS 0V / 50 Hz SU G V / 50 Hz PV V / 50 Hz S G MS 4V / G G G G G SL S G SL ll leafl ets are available on: prefi x pipe thread basic number voltage suffi x 007/R 第 /0 页

3 SRIS XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected level (LP, RP, MP or P) and the TX safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I 5 Standard voltages (=) 4V - 4V (~) 4V - 4V - 5V - 0V/50Hz; other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/ temperature enclosure cold safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) (N 605) 0 V / 50 Hz 4 V type () asic (P) S /6, -5 to +60 N 6070 moulded IP SU /6, -5 to +60 II IP65 T 5 moulded IP65 - (4) - (4) 0 PV /6, -40 to +65/40 II G/ x m II T (-) moulded IP65 - (4) - (4) 04 Medium (MP) PV 5 4,5/4,0-40 to +60 II G/ x m II T4 () / T5 () moulded IP65 - (4) - (4) 0 Reduced (RP) S 6,5,5,5/,0-5 to +60 N 6070 moulded IP SU 6,5,5,5/,0-5 to +60 II IP65 T 00 moulded IP65 - (4) - (4) 0 () Refer to the dimensional drawings on pages 4 and 5 (ir operated versions, see page 6 for types 5 and 6). (4) Multiple coil kits available under TX, contact us LTRIL ONNTIONS prefix connection S, SU Spade plug connector with cable gland IN 4650, mm, industry standard, for cables with an outer diameter from 6 to mm (type 0) or N750-0 (ISO 4400) for cables with an outer diameter from 6 to 0 mm (type 0). PV Moulded-in cable, standard length m ITIONL OPTIONS Other pipe threads are available on request x m (prefi x "PV") execution can be supplied in various cable lengths ompliance with "UL" vailable on request (series 55-55) ustproof TX (SU) with a coil and spade plug connector with lead ( m lead), TPL 065 Magnetic latch execution for 55 series, TPL 064 INSTLLTION Installation/maintenance instructions are included with each valve The valves can be mounted in any position without affecting operation I 650 Functional Safety (Suffi x SL), allowable temperature range: -40 to +60. Probability of failure on demand, contact us It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the valve if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifi er is: = NPT (NSI.0.); G = G (ISO /) 第 /0 页 ll leafl ets are available on: /R0

4 SRIS IMNSIONS (mm), WIGHT (kg) TYP 0: Prefixes S: IP65, SU: II, IP65, T5 to 5 Reduced poxy moulded I 5 / IN 4650 TYP 0: Prefixes S: IP65, SU: II, IP65, T5 to 5 asic poxy moulded I 5 / ISO / 005MS / 006 / 006MS / 005MS / 006 / 006MS / 005MS / 006 / 006MS F x /4 F x / (55) - / (55) G H 0 60 I 0 J P Q K H L M N O G H 60 0 I J P Q K 0 H L M N O mounting holes dia. 5,; spotfacing: dia., depth 5 mm mounting holes dia. 6,5; spotfacing: dia., depth 6 mm TYP 0: Prefix: PV: II G, IP65, x m II Medium poxy encapsulated N500 and N 50-- TYP 04: Prefix: PV: II G, IP65, x m II asic poxy encapsulated N500 and N / 005MS / 006 / 006MS / 005MS / 006 / 006MS / 005MS / 006 / 006MS F x /4 F x / (55) - / (55) G 60 I 0 J P Q K L M N O G 60 0 I J P Q K L M N O type prefix weight () F G H I J K L M N O P Q option level monost. bistable 0 (55) S / SU RP 7,5,5 4, ,5 0,5 0,4 0 (55) S / SU P 40, 6 4, 56,,,6 70,, 5 7, 0,, 7,5 0,70,00 0 (55) S / SU P 40, 6 4, 56,,,6 70,, 5 7, 0,,,5 0,6 0, 0 (55) PV MP 7,5,5 4,5, ,5 0,7 0,4 04 (55) PV P 40, 6 4, 6,5,,6 70,, 5 7, 0,,, 7,5 0,7,0 04 (55) PV P 40, 6 4, 6,5, 0,6 70,, 5 7, 0,,,,5 0,7,0 () Including coil(s) and connector(s). ll leafl ets are available on: 第 4/0 页 007/R0

5 SRIS SSORIS SRIS 55, 55 and 55 Supply rail (supplied with seals and banjo bolts, without mounting brackets) catalogue number supply rail for "n" valves series 55 series 55 series 55 G /4 NPT /4 G / NPT / G / NPT / () () vailable on request. Mounting brackets (set of ), for series 55: catalogue number 0004 for series 55-55: catalogue number 0077 supply rail with isolation valves (without mounting brackets) () - allows the isolation of one or more valves from the general pressure supply () supply rail for "n" valves catalogue number 7 G / Series number of valves type, monost.* 0,,,7,0,4,, type, bistable*,,7,,6,,6 4, Ø 5,7 G/4 5,5 Series number of valves type, monost.*,,, 4,7 5,6 6,4 7,4 type, bistable*,5,6 4, 5, 7,,, * Weight (kg) () () () or () supply rail () mounting bracket (x) G / (55) G /4 (55-55) 60 0 ( ) (55) (55) (55-55) (55) 4 (55-55) (55) 7 (55-55) 75 (55) 0 (55-55) 4Ø 6,5 (55) 4Ø (55-55) (55), (55-55) 50 (55) 75 (55-55) 7 (55) 7,5 (55-55) 5 (55) 5 (55-55) 7 (55) 0 (55-55) 4 (55) 0 (55-55) (55) (55-55) 4 (55) 60 (55-55) This mounting arrangement allows valves to be mounted in any of 4 positions. ( ) ( ) (55) (55) 6, (55-55) 5 (55) 6, (55-55) (55) ( ) ( ) (55) ( ) (55) ll leafl ets are available on: 007/R0 第 5/0 页

6 IMNSIONS (mm), WIGHT (kg) TYP 05: No prefix (suffixes "G", "SL" or "GSL") ir operated version (supply rail - see below) TYP 06: No prefix (suffix "G") ir operated version 5505 / / 5506 / 5505 / 5506 G/ L F 0 I J P Q K x /4 M mounting holes dia. 5,; spotfacing: dia., depth 5 mm mounting holes dia. 6,5; spotfacing: dia., depth 6 mm G/4 F I P Q J K x / (55) - / (55) L M type F I J K L M P Q weight monost. bistable 05 (55) 7,5 50,5 6 45,5 0, 0,6 06 (55) 40, 6 7,5 75,6 4, ,, 7,4 0,,07 06 (55) 40, 6 7,5 74,6 4, ,,,4 0,0,06 SSORIS SRIS 55, 55 and 55 Supply rail (supplied with seals and banjo bolts, without mounting brackets): see catalogue numbers on page 5 Series number of valves () type 5, monost.* 0,,,5,,,5, type 5, bistable*,0,4,,,7,,5 Series number of valves type 6, monost.*,,0, 4,7 5,5 6, 7, type 6, bistable*,5,5 4,6 5,7 6,7 7,7,7 * Weight (kg) () or () supply rail () mounting brackets (x) () 75 () G /) 0 7,5 4 This mounting arrangement allows valves to be mounted in any of 4 positions. 4Ø 6, ll leafl ets are available on: 第 6/0 页 007/R0

7 SOLNOI VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 to / 0 / Series FTURS The monostable spool valves, series 55, have TÜV certifi ed I 650 Functional Safety data and can be used up to SIL 4/K 7 The spool valves / N have threaded port connections ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by fl ipping a gasket The solenoid valves satisfy all relevant irectives GNRL ifferential pressure Flow (Qv at 6 bar) - 0 bar [ bar = 00 kpa] /4 = 60 l/min (NR) / = 000 l/min / = 00 l/min fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, fi ltered - 5 to + 60 NR (nitrile) + PUR (polyurethane) MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody luminium, black anodised nd cover (spring return) Glass-fi lled P Spool valve internal parts Zamak, stainless steel, POM, aluminium Pilot internal parts Refer to specific solenoid catalogue pages Pilot end covers luminium ore tube Stainless steel ore and plugnut Stainless steel ore spring Stainless steel Seals NR Top disc P isc holder artridge (low ) Welded, packless ISI 40 Seat rass Seat insert Shading coil opper Rider rings (low ) PTF UP LP Not available 0,4W -,W RP-MP P Not available 0,5W -,W Ultra Low Low Reduced and Medium asic SPIFITIONS operating pressure flow prefix optional solenoids pipe orifice differential (bar) coefficient basic max. (PS) level kv NM TX/NL (gas/dust) catalogue IP65 min. () air ( ) 7 & x d x em x m x i x n number ( ) (mm) (m /h) (l/min) ~ = ~/= F NF NK M PV IS ZN S Solenoid air pilot operated - spring return (monostable) /4 6 0,75,5 0/ 0 0 P () /4 6 0,75,5 0/ 0 0 P H405 () /4 6 0,75,5 0/ 0 0 LP () /4 6 0,75,5 0/ 0 0 LP H05 () /,4 4,5 0/ 0 0 P /,4 4,5 0/ 0 0 P G405 /,4 4,5 0/ 0 0 LP /,4 4,5 0/ 0 0 LP G05 /,5 5,5 0/ 0 0 P /,5 5,5 0/ 0 0 P G405 /,5 5,5 0/ 0 0 LP /,5 5,5 0/ 0 0 LP G05 Select for NPT NSI.0. or select G for ISO G (/) vailable feature vailable feature in only - Not available () ertified I 650 Functional Safety data, use suffi x "SL". () Zero minimum is only achieved if external pressure is applied. ll leafl ets are available on: 第 7/0 页 POWR LVLS - cold electrical holding values (watt) /R0

8 SPIFITIONS pipe ll leafl ets are available on: orifice flow coefficient kv operating pressure differential (bar) prefix optional solenoids max. (PS) level NM TX/NL (gas/dust) min. () IP65 air ( ) 7 & x d x em x m x i x n ( ) (mm) (m /h) (l/min) ~ = ~/= F NF NK M PV IS ZN S Solenoid air pilot operated and return (bistable) SRIS PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page 7. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations table above. xample : G55405 STP Select prefi x (combination). Select the appropriate operator from the specifi cations table on page 7 and the prefi x table on page. Select for this operator in the electrical characteristics table on page : the level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. xample : M STP Select suffi x (combination) if required. xample : MO STP 4 Select voltage. Refer to standard voltages on page. xample : 0V / 50Hz STP 5 Final catalogue / ordering number. xample : M G55405MO 0 V / 50 Hz ORRING XMPLS: S G V / 50 Hz S G SL 0V / 50 Hz S G MO 0V / 50 Hz SHT MO 0V / 50 Hz ISS G MO 4V/ WPIS V / M MO 0V / 50 Hz F G 55 H 405 MO 40V / 60 Hz prefi x (6) pipe thread basic number (6) basic catalogue number /4 6 0,75,5 0/ 0 0 P /4 6 0,75,5 0/ 0 0 P H406 /4 6 0,75,5 0/ 0 0 LP /4 6 0,75,5 0/ 0 0 LP H06 /,4 4,5 0/ 0 0 P /,4 4,5 0/ 0 0 P G406 /,4 4,5 0/ 0 0 LP /,4 4,5 0/ 0 0 LP G06 /,5 5,5 0/ 0 0 P /,5 5,5 0/ 0 0 P G406 /,5 5,5 0/ 0 0 LP /,5 5,5 0/ 0 0 LP G06 Select for NPT NSI.0. or select G for ISO G (/) vailable feature vailable feature in only - Not available () Zero minimum is only achieved if external pressure is applied PRFIX TL prefi x level description LP RP MP P S U ustproof TX (N 50--)* F xplosionproof - NM, 4, 6, 7, - - M ncapsulated TX (N 500 & N 500)* - - T Threaded conduit/hole (M0 x.5) - - I S S Intrinsically safe with S coil TX (N 5000)* N F Flameproof - lum. TX (N 500)* - - N L Flameproof - ast Iron TX (N 500)* - - N K Flameproof - lum. TX (N 500) * P V ncapsulated TX (N 500)* - - S Solenoid with spade plug connector (N 6070) - - W P Waterproof IP67 - Metal enclosure (N 6070) - - W P U ustproof TX (N 50--) - Metal enclosure* W P I S I.S. with Metal IP67 enclosure TX (N 5000)* W P Z N N.S. metal enclosure TX (N 500)* - - W S Waterproof IP67-6 SS enclosure - - W S U ustproof TX (N 50--) - 6 SS enclosure* W S M 6 SS "M" enclosure TX (N 500, N 5000)* - - W S N F Flameproof - Stainless steel 6 TX (N 500) * - - W S Z N N.S. 6 SS enclosure TX (N 500)* - - Z N ncapsulated Non Sparking TX (N 500)* - - T Threaded conduit (/" NPT) - - H T lass H - High temperature M F Low temperature -40 (series 55) - - X Other special constructions - - SUFFIX TL suffi x level 4 5 description LP RP MP P M O Push type or screw type manual operator - - S L ertifi ed I 650 Functional Safety data (4) - - * TX solenoids are also approved to N 50-- (dust) and N 46- (non electrical valves) vailable feature vailable feature in only - Not available (4) Not to use with MO suffi x OPTIONS & SSORIS series pipe exhaust protector (stainless steel) (G) (NPT) - 55/55/55 / (5) (5) - 55 / (5) (5) - 55 / / (5) Provided with "SL" suffi x. 第 /0 页 (6) Prefix F should always be used with the letter H in the basic number. voltage suffi x 007/R0

9 SRIS XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected level (LP, RP, MP or P) and the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I 5 Standard voltages (=) 4V - 4V (~) 4V - 4V - 5V - 0V/50Hz; other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/ temperature enclosure cold safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) (N 605) 0 V / 50 Hz 4 V type () asic (P) S 55 0,5 /, -40 to +75 N 6070 moulded IP SU 55 0,5 /, -40 to +75 II IP65 T 00 (~)/5 (=) moulded IP65 - (4) - (4) 0 WP/WS 55 0,5 /, -40 to +75 N 6070 steel/ss IP WPU/WSU 55 0,5 /, -40 to +75 II IP67 T 00 steel/ss IP67 - (4) - (4) 04 (WS)NF/NL 55 0,5 - [-60] () -40 to +5/40/60 II G/ x d II T6/T5/T4 alu./ss/steel IP (WS)NF/NL /, [-60] () -40 to +40/60/75 II G/ x d II T6/T5/T4 alu./ss/steel IP NK 55 0,5 /, -40 to +50/60 II G/ x d II+H T4(~/=) aluminium IP M/WSM 55 0,5 /, -40 to +40 II G/ x em II T steel/ss IP PV 55 0,5 /, -40 to +65 II G/ x m II T(~)/T4(=) moulded IP65 - (4) - (4) 05 F 55 0,5 /, -40 to +54/40 NM type 7 and NM 4X ZN 55 0,5 /, -0 to +50 II G/ x n II T moulded IP65 - (4) - (4) 0 WP(WS)ZN 55 0,5 /, -40 to +50/60 II G/ x n II T(~)/T4(=) steel/ss IP67 - (4) - (4) 04 Low (LP) S,5,5,5,7/,7-40 to +60 N 6070 moulded IP WP/WS,5,5,5,7/,7-40 to +60 N 6070 steel/ss IP (WS)NF/NL - -, - /, [-60] () -40 to +75/0 II G/ x d II T6/T5 alu./ss/steel IP67 - (4) - (4) 0 M/WSM,5,5,5,7/,7-40 to +40/55 II G/ x em II T6/T5 steel/ss IP67 - (4) - (4) 0 PV - - -,7/,7-40 to +60 II G/ x m II T6 moulded IP (4) 0 F - - -,7/,7-40 to +40 NM type 7 and NM 4X - - (4) ISS () ,4/04-40 to +60 II G/ x ia II T6 moulded IP WPIS () ,4/04-40 to +60 II G/ x ia II T6 acier IP ZN - - -,7/,7-0 to +50 II G/ x n II T moulded IP (4) 07 WP(WS)ZN,5,5,5,7/,7-40 to +60 II G/ x n II T6 steel/ss IP67 - (4) - (4) 0 prefix option safety parameters U I = () I I P I L I I (V) (m) (W) (µf) (mf) Low (LP) ISS 500,5 0 0 WPIS 500,5 0 0 LTRIL ONNTIONS prefix connection S, SU, ZN WP, WS, M, WSM, WPU, WSU NF, WSNF, NL NK PV F ITIONL OPTIONS () The certified minimum temperature of this operator () Refer to the dimensional drawings on pages 0 to. () Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (ISS/WPIS operators). (4) Multiple coil kits available under TX, contact us - Not available Spade plug connector with cable gland N750-0 (ISO 4400) for cables with an outer diameter from 6 to 0 mm M0 cable gland for cables with an outer diameter from 7 to mm. With an internal and external facility for an earthing or bonding conductor /" NPT threaded cable entry. nclosures are supplied without cable gland /4" NPT threaded cable entry. nclosures are supplied without cable gland Moulded-in cable, standard length m /" NPT conduits, standard length 5 cm Valves confi gured for external pilot air supply, TPL 0547 Other pipe threads are available on request x m (prefi x "PV") execution can be supplied in various cable lengths ompliance with "UL", "S" and other local approvals available on request /" NPT (prefi x "T") and M0 x.5 (prefi x "T") conduits (aluminium or 6 SS) available for steel solenoid housing INSTLLTION Installation/maintenance instructions are included with each valve The solenoid valves can be mounted in any position without affecting operation I 650 Functional Safety (Suffi x SL), allowable temperature range: -40 to +60. Probability of failure on demand, contact us It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifi er is: = NPT (NSI.0.); G = G (ISO /) x d (prefi x "NF") enclosure is provided with a /" NPT threaded entry hole [optionally, M0 x,5 (prefi x "T")] and is supplied without cable gland x d (prefi x "NK") enclosure is provided with a /4" NPT threaded entry hole [optionally, /" NPT (prefi x "T") or M0 x,5 (prefi x "T")] and is supplied without cable gland 第 /0 页 ll leafl ets are available on: /R0

10 SRIS IMNSIONS (mm), WIGHT (kg) Types 0 to Series 55 Series ,5 / 6,5 x /4 7, , / x / (55) - / (55) 6,5 6 45,5, 0,5 7 mounting holes dia. 5, mm Spotfacing: dia. mm, depth 5 mm, 7,4 (55),6 (55),4 (55),6 (55) 5,5 5 7, mounting holes dia. 6,5 mm Spotfacing: dia. mm, depth mm / 406 / 405MO / 406MO / 406 / 405MO / 406MO / 406 / 405MO / 406MO TYP 0: Prefixes S: IP65, ZN: II G/, IP65, x n II, SU: II, IP65, T00 to 00 asic poxy moulded I 5 / ISO / 406 / 405MO / 406MO / 406 / 405MO / 406MO / 406 / 405MO / 406MO TYP 0: Prefixes NF/NL/WSNF: II G/, IP67, x d II asic luminium, epoxy coated (NF) ast iron, epoxy coated (NL) ISI 6 SS (WSNF) N 500 and N / / NPT / 406 / 405MO / 406MO / 406 / 405MO / 406MO / 406 / 405MO / 406MO TYP 0: Prefix NK: II G, IP65, x d II + H asic luminium, epoxy coated N 500 and N 50-- TYP 04: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x em II, WPU/WSU: II, IP67, T5 to 00, WPZN/WSZN: II G/, IP67, x n II asic Steel, epoxy coated (M, WP, WPU, WPZN) ISI 6 SS (WS, WSU, WSM, and WSZN) I 5 / N 500, N 500 and / 406 / 405MO / 406MO / 406 / 405MO / 406MO / 406 / 405MO / 406MO / / 4 /4 NPT ,5 64, ll leafl ets are available on: 第 0/0 页 007/R0

11 SRIS IMNSIONS (mm), WIGHT (kg) TYP 05: Prefix: PV: II G/, IP65, x m II asic poxy encapsulated N500 and N 50-- TYP 06: Prefix: F: IS-6 NSI / NM type 7 and asic poxy encapsulated N500 and N 50-- NOT: applicable to solenoid only / 406 / 405MO / 406MO / 406 / 405MO / 406MO / 406 / 405MO / 406MO 55H405 / H406 / H405MO / H406MO 55G405 / G406 / G405MO / G406MO 55G405 / G406 / G405MO / G406MO / / / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO TYP 07: Prefixes S: IP65, ZN: II G/, IP65, x n II Low poxy moulded I 5 / ISO / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO TYP 0: Prefixes NF/NL/WSNF: II G/, IP67, x d II Low luminium, epoxy coated (NF) ast iron, epoxy coated (NL) ISI 6 SS (WSNF) N 500 and N 50-- / NPT / NPT TYP 0: Prefixes WP/WS: IP67, M/WSM: II G/, IP67, x em II, WPU/WSU: II, IP67, T5 to 00, WPZN/WSZN: II G/, IP67, x n II, WPIS: II G/ x ia II Low Steel, epoxy coated (M, WP, WPU, WPZN, WPIS) ISI 6 SS (WS, WSU, WSM, and WSZN) I 5 / N 500, N 500 and / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO TYP 0: Prefix: PV: II G/, IP65, x m II Low poxy encapsulated N500 and N 50-- / NPT 4 / NPT 第 /0 页 ll leafl ets are available on: /R0

12 SRIS IMNSIONS (mm), WIGHT (kg) TYP : Prefix: F: IS-6 NSI / NM type 7 and Low poxy encapsulated N500 and N 50-- NOT: applicable to solenoid only TYP : Prefixes ISS: II G/ x ia II, IP65 Low Polypropylene moulded I 5 / ISO 4400 N 5000 and N H05 / H06 / H05MO / H06MO 55G05 / G06 / G05MO / G06MO 55G05 / G06 / G05MO / G06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO 5505 / 06 / 05MO / 06MO / / NPT x d certifi ed cable gland (on request) Three-core cable, length m 4 able gland for unarmoured cable with 7 to mm dia. sheath 6 onnector rotatable by 0 increments, Pg P (Ø 6-0 mm) 7 Screw type manual operator, suffi x MS Push type or screw type manual operator, suffi x MO xternal pilot air supply, / pipe onnectable pilot exhaust port Non-connectable pilot exhaust port type prefix option level weight () monostable bistable 55 55/ 55/ 55/ 55/ 55/ S / SU / ZN P 5,5 70 0,7,,5 6,5 6,5 00, 0,76,45,5,4,0, 0 NF / NL / WSNF P 5 7, 4 7,6 4, 5, ,5,4,,5 4,5 4,05 0 NK P 4 66, , ,0,7,7,4,5,4 04 WP/WS/WSU/WPU P 4 6, 04, 0, ,4,46,6,4,0, 04 (WS)M/WP(WS)ZN P 4 6, 04, 0, ,4,46,6,4,0, 05 PV P 5,5 7 7,5,5 6,5 67,5, 0,,46,6,45,0, 06 F P, ,5 5,5 6,5 74,5, 0,64,46,6,,0, 07 S / ZN LP,5 5, ,5,5 6,5 7,5 0, 0,7,66,56,55,,6 0 NF / NL / WSNF LP 5 7, 4 7,5 4, 5, ,5,4,,5 4,5 4,05 0 WP/WS/(WS)M LP 4 6, 04, 0,, ,05,67,57,70,,4 0 WP(WS)ZN LP 4 6, 04, 0,, ,05,67,57,70,,4 0 WPIS LP 4 6, 04, 0,, ,05,67,57,70,,4 0 PV LP 5,5 7 00,5 0,5 6,5 67,5,,0,67,57,67,, F LP, ,5 0,5 6,5 74,5, 0,5,67,57,50,4,4 ISS LP ,5 4,5 6,5,5 0,5 0,0,4,,4,05,5 () Including coil(s) and connector(s). SSORIS ø4 / NPT ø4 /4 NPT Ø 0 / NPT pilot exhaust protector part no ll leafl ets are available on: pilot top exhaust low (SO solenoid interface) Ø / /4 / / exhaust protector (stainless steel) 第 /0 页 007/R0

13 SOLNOI VLVS solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 to / 0 / Series FTURS The monostable spool valves, series 55, have TÜV certifi ed I 650 Functional Safety data and can be used up to SIL 4/K 7 The spool valves / N have threaded port connections ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by fl ipping a gasket Ultra low level for inside application, suitable to connect to process fi eldbus remote I/O or valve couplers The solenoid valves satisfy all relevant irectives GNRL ifferential pressure - 0 bar [ bar = 00 kpa] Flow (Qv at 6 bar) /4 = 60 l/min (NR) / = 000 l/min / = 00 l/min fluids ( ) temperature range (TS) seal materials ( ) - 5 to + 40 air, inert gas, fi ltered - 5 to + 60 NR (nitrile) + PUR (polyurethane) () With series 0 pilots, prefi xes FS/FS/FVT/FL/FSIS/FSIS/FVTIS/FSZN/FVTZN. MTRILS IN ONTT WITH FLUI ( ) nsure that the compatibility of the fluids in contact with the materials is verified ody luminium, black anodised nd cover (spring return) Glass-fi lled P Spool valve internal parts Zamak, stainless steel, POM, aluminium Pilot internal parts Size 0 ( ), refer to specifi c catalogue pages: 74 pilots (TNK) and 5 (ISS) Size 5 (06.6.0N), refer to specifi c catalogue pages: 0 pilots (FS/FS/FVT/FL/ FSIS/FSIS/FVTIS/FSZN/FVTZN) and 60 piezotronic (PIS-PISIS) Pilot end covers luminium UP LP 0,00W - 0,5W 0,5W -,6W RP-MP P Not available 0,5W -,W Ultra Low Low Reduced and Medium asic SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) min. level prefix optional solenoids max. (PS) TX/NL (gas/dust) IP65 air ( ) x d x i x i x i x n NOMO 0 basic catalogue number NOMO 5 ( ) (mm) (m /h) (l/min) ~ = ~/= TNK ISS FSIS PISIS FSZN FS PIS Solenoid air pilot operated - spring return (monostable) /4 6 0,75,5 0 0 LP () /4 6 0,75,5 - LP () /4 6 0,75,5 0 0 P () - /4 6 0,75,5 - LP () - /4 6 0,75,5 UP () /,4 4,5 0 0 LP /,4 4,5 - LP /,4 4,5 0 0 P /,4 4,5 - LP /,4 4,5 UP /,5 5,5 0 0 LP /,5 5,5 - LP /,5 5,5 0 0 P /,5 5,5 - LP /,5 5,5 UP Select for NPT NSI.0. or select G for ISO G (/) vailable feature vailable feature in only - Not available () ertifi ed I 650 Functional Safety data, use suffi x "SL". 第 /0 页 POWR LVLS - cold electrical holding values (watt) ll leafl ets are available on: /R0

14 SPIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) min. level prefix optional solenoids SRIS max. (PS) TX/NL (gas/dust) IP65 air ( ) x d x i x i x i x n NOMO 0 basic catalogue number NOMO 5 ( ) (mm) (m /h) (l/min) ~ = ~/= TNK ISS FSIS PISIS FSZN FS PIS Solenoid air pilot operated and return (bistable) /4 6 0,75,5 0 0 LP /4 6 0,75,5 - LP /4 6 0,75,5 0 0 P /4 6 0,75,5 - LP /4 6 0,75,5 UP /,4 4,5 0 0 LP /,4 4,5 - LP /,4 4,5 0 0 P /,4 4,5 - LP /,4 4,5 UP /,5 5,5 0 0 LP /,5 5,5 - LP /,5 5,5 0 0 P /,5 5,5 - LP /,5 5,5 UP PRFIX TL prefi x level description UP LP RP P NOMO solenoid (pilot) interface 0 I S S Intrinsically safe with pilot 5, TX (N 5000) * T N K Flameproof with pilot 74, TX (N 500) * NOMO solenoid (pilot) interface 5 F S Solenoid + spade plug MP,5x0,5,,4 mm, (N 6070), 0 pilot F S Solenoid + spade plug ISO 57, mm, (N 6070), 0 pilot F V T Solenoid with M connection, L + protection (N 6070), 0 pilot F L Solenoid with cable ends, L + protection (N 6070), 0 pilot F S I S Intrins. safe, spade plug connector, pilot 0; TX (N 5000) * F S I S Intrins. safe, spade plug ISO 57, mm, pilot 0; TX (N 5000) * F V T I S Intrins. safe, connector M (straight), L + protection, pilot 0; TX (N 5000) * F S Z N Non sparking, spade plug connector,4 mm, pilot 0; TX (N 500) * F V T Z N Non sparking, connector M (straight), L + protection, pilot 0; TX (N 5000) * P I S Solenoid with spade plug connector (N 6070), 60 piezotronic pilot P I S I S Intrinsically safe with piezotronic pilot 60; TX (N 5000) * SUFFIX TL suffi x level description 4 5 UP LP RP P NOMO solenoid (pilot) interface 0 M S Screw type manual operator () M O Push type or screw type manual operator () S L ertifi ed I 650 Functional Safety data (monostable) NOMO solenoid (pilot) interface 5 M S Screw type manual operator () M O Push type manual operator / / - - S L ertifi ed I 650 Functional Safety data (monostable) / / - - PROUT SLTION GUI STP Select the fl uid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identifi cation letter. Refer to the specifi cations tables on pages and 4. xample : G55505 STP Select prefi x (combination). Select the appropriate operator from the tables on pages and 4. Select for this operator in the electrical characteristics table on page 5: the level (UP, LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. xample : FS STP Select suffi x. Suffi x MO mandatory for the pilot 0 (FSIS/FSIS/FVTIS). Refer to the suffi x table on page 4, respect the indicated level. xample : MO STP 4 Selection of TPL is mandatory for the 60 pilot (PISIS), HV ( mw) and 4 HV (5 mw). dd "X" between the prefix "PISIS" and the basic catalogue number. STP 5 Select voltage. Refer to standard voltages on page 5. xample : 0V / 50Hz STP 6 Final catalogue / ordering number. xample : FSG55505MO 0 V / 50 Hz OPTIONS & SSORIS series ll leafl ets are available on: pipe exhaust protector (stainless steel) (G) (NPT) - 55/55/55 / () () - 55 / () () - 55 / / /55/ () Select for NPT NSI.0. or select G for ISO G (/) vailable feature vailable feature in only - Not available * TX solenoids are also approved to N 50-- (dust) and N 46- (non electrical valves) () Not to use with SL suffi x () Provided with SL suffi x (series 55) 第 4/0 页 ORRING XMPLS: TNK G V / 50 Hz TNK G MS 5V / 50 Hz TNK G SL 4V / ISS G SL 4V / FS G V / 50 Hz FS MO 0V / 50 Hz FS G SLMO 0V / 50 Hz FVTZN G V / 50 Hz FVTZN G V / ISS G MO 4V / PISIS G MO 6V / PISIS G SLMO 6V / PISIS X G MO TPL0666 4HV / prefi x voltage pipe thread TPL basic number suffi x 007/R0

15 XPLNTION OF TMPRTUR RNGS OF SOLNOI VLVS Valve temperature range The valve temperature range is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected level (LP, RP, MP or P) and the TX safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above LTRIL HRTRISTIS oil insulation class F lectrical safety I 5 Standard voltages (=) TNK : 4V - 4V ; FS/FS/FSZN : V - 4V ; FVT/FL/FVTZN : 4V FSIS/FSIS/FVTIS : V - 4V ; ISS : 4V, PIS : 4V à 70V ; PISIS : 6V, V, V, 4V (~) TNK : 4V - 4V - 5V - 0V/50Hz ; FS/FS/FSZN : 4V - 5V - 0V/50Hz ; PIS : 4V to 70V - Other voltages and 60Hz are available on request ratings operator electrical ambient replacement coil prefix inrush holding hot/ temperature enclosure cold safety code option ~ ~ = range (TS) protection ~ = (V) (V) (W) (W) ( ) (N 605) - - type () asic (P) TNK 55 0,5 /, -0 to +50/60 II G/ x d II+H T4(/) aluminium IP Low (LP) FS/FS,4,, /, -5 to +60 N 6070 moulded IP FS/FS, (7),6 (7),5 (7) - -5 to +60 N 6070 moulded IP FVT/FL (6) - - -,5/,5-5 to +60 N 6070 moulded IP67/IP FSZN,4,, /, -5 to +60 II G x n II T5 moulded IP FSZN, (7),6 (7),5 (7) - -5 to +60 II G x n II T5 moulded IP67/IP FVTZN - - -,5/,5-5 to +60 II G x n II T5 moulded IP FSIS (4)(5) ,5-0 to +50 II G x ia II T5 (V)/T6 (4V) moulded IP FSIS (4)(5) ,5-0 to +50 II G x ia II T5 (V)/T6 (4V) moulded IP FVTIS (4)(5) ,5-0 to +50 II G x ia II T5 (V)/T6 (4V) moulded IP ISS ()(4) - - -,6-40 to +50 II G/ x ia II T6 moulded IP Ultra low (UP) PIS ,007-0 to moulded IP PISIS ()(4) 6V ,00-0 to +50 II G x ia II T6 moulded IP PISIS ()(4) V ,0-0 to +50 II G x ia II T6 moulded IP PISIS ()(4) LV ,0-0 to +50 II G x ia II T6 moulded IP PISIS ()(4) HV ,0-0 to +50 II G x ia II T6 moulded IP PISIS ()(4) 4LV ,046-0 to +50 II G x ia II T6 moulded IP PISIS ()(4) 4HV ,5-0 to +50 II G x ia II T6 moulded IP () Piezotronic standard voltages: Prefi x PIS, 4 V to 70 V /, peak current max. : 0 m, holding current max. : m Prefi x PISIS: 6 V / mw V / mw L V / mw H V / mw 4L V / 46 mw 4H V / 5 mw Turn ON voltage U ON 6.. V 7,.. V 0,.. 6 V 0,.. 6 V,6.. V,6.. V Turn OFF voltage U OFF V, V, V, V 5 V 5 V Peak current 6 m 0 m 6, m, m 0 m 4 m Holding current 0,5 m, m m,7 m, m 5, m able + max. barrier resistances (R S + R ) 00 Ω max. 00 Ω max. 00 Ω max. 470 Ω max. 00 Ω max. 470 Ω max. () safety parameters Refer to the dimensional drawings on pages 6 to. () Min. operating current (I min. ): 0,07 U I = () I I P I L I I (4) Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (V) (m) (W) (µf) (mf) (FSIS/ISS/PISIS: 0/5/60 pilots). (5) FSIS/FSIS/FVTIS (0 pilots): V : I (ON) min., with L = m; U (ON) min.=, V; U (max.) recommended = V; U (OFF) =, V; I (OFF) = 0 m 4 V : I (ON) min., with L = 5 m; U (ON) min.= 6,4 V; U (max.) recommended = V; U (OFF) = 5,7 V; I (OFF) = 7 m (6) Values for L + protection. Use with TPL 0674 (FS and FS prefi xes) prefix option Low (LP) FSIS 00,6 0 0 FSIS/FVTIS 00,6 0 0 ISS 5,6 0 0 Ultra low (UP) PISIS , 0 0 LTRIL ONNTIONS (7) : 0V - Not available prefix connection TNK /4" NPT threaded cable entry. nclosures are supplied without cable gland ISS Spade plug connector with cable gland N750-0 (ISO 4400) for cables with an outer diameter from 6 to mm FS, FSIS, FSZN, PIS, PISIS Spade plug connector with cable gland IN 4650,,4 mm, industry standard, for cables with an outer diameter from 4 to 6 mm FS, FSIS Spade plug connector with cable gland ISO 57 / IN 4650, mm, form, for cables with an outer diameter from 4 to 6 mm FVT M connection for M connector FVTIS Straight M connector for cables with an outer diameter from,5 mm to 6,5 mm FVTZN Straight M connector with moulded-in cable, standard length 5 m FL Moulded-in fl ying lead, standard length 0, m TNK /4" NPT threaded cable entry. nclosures are supplied without cable gland ITIONL OPTIONS TPL numbers: TPL 0665: Piezotronic, PISIS prefix, HV ( mw); TPL 0666: Piezotronic, PISIS prefix, 4 HV (5 mw) TPL 0674: L and protection, FS / FS prefi xes, only available in 4 V / and 5 V - dd 0,5 W () and 0,4 W/V () Other pipe threads are available on request INSTLLTION Installation/maintenance instructions are included with each valve The valves can be mounted in any position without affecting operation I 650 Functional Safety (Suffi x SL), allowable temperature range: -40 to +60. Probability of failure on demand, contact us It is necessary to connect pipes or fi ttings to the exhaust ports to protect the internal parts of the valve if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifi er is: = NPT (NSI.0.); G = G (ISO /) x d (prefi x "TNK") enclosure is provided with a /4" NPT threaded entry hole [optionally, /" NPT (prefi x "T") or M0 x,5 (prefi x "T")] and is supplied without cable gland Valves with suffi x "SL" are provided with specifi c exhaust protectors 第 5/0 页 SRIS ll leafl ets are available on: /R0

16 IMNSIONS (mm), WIGHT (kg) Types 0 and 0 Series 55 Types 0 to 0 Series 55 Types 0 to 0 Series x /4 7,5 4,5, 45 = = x / (55) - / (55) 7,5 6 40, 45 4,4 x G/4,,55 5 7,,5 6,5 4 0,5 7,5 TYP 0: Prefix TNK: II G, IP65, x d II + H asic 74 pilot, light alloy luminium, epoxy coated N 500 and N 50-- TYP 0: Prefix ISS: II G x ia II, IP65 Low 5 pilot Polyamide I 5 / ISO 4400 N 5000 and N MS / 06MS 5505MS / 06MS 5505MS / 06MS G/ /4 NPT MO / 06MO 5505MO / 06MO 5505MO / 06MO = =, 75,6 (55) 74,6 (55) 4,5 6 7,4 (55),4 (55) mounting holes dia. 5, mm Spotfacing: dia. mm, depth 5 mm mounting holes dia. 6,5 mm Spotfacing: dia. mm, depth 6 mm 6 5,5 64, TYP 0: Prefixes FS and FS: IP65 Low Pilote 0 Polyarylamide I / MS / 55505MO / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO ll leafl ets are available on: 第 6/0 页 007/R0

17 SRIS IMNSIONS (mm), WIGHT (kg) TYP 04: Prefix FVT: IP67 (with M connector mounted) Low Pilot 0 Polyarylamide I 5 / connection M + L and protection / MS / 55505MO / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO 4, TYP 05: Prefix FL: IP65 Low Pilot 0 Polyarylamide I 5 / fl ying lead + L and protection / MS / 55505MO / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO / 505MS / 505MO / 506 / 506MS / 506MO 4,5 54,5 74 TYP 06: Prefixes PIS: IP65, PISIS: II G x ia II, IP65 Low Piezotronic pilot, Polyamide poxy moulded I 5 / IN 4650 N5000 and N MO / 55506MO 55505MO / 506MO 55505MO / 506MO 第 7/0 页 ll leafl ets are available on: /R0

18 SRIS IMNSIONS (mm), WIGHT (kg) TYP 07: Prefix FSZN: II G, IP65, x n II Low Pilot 0, Polyarylamide onnector with L and protection N500 and N MO / 55506MO 55505MO / 506MO 55505MO / 506MO TYP 0: Prefix FVTZN: II G, IP67, x n II Low Pilot 0, Polyarylamide onnector M + L and protection N500 and N MO / 55506MO 55505MO / 506MO 55505MO / 506MO 4,5 54 4,5 7 TYP 0: Prefixes FSIS and FSIS: II G x ia II, IP65 Low Pilot 0, Polyarylamide I 5 / IN 4650 or ISO 57 onnector + L and protection N5000 and N MO / 55506MO 55505MO / 506MO 55505MO / 506MO ll leafl ets are available on: 007/R 第 /0 页

19 SRIS IMNSIONS (mm), WIGHT (kg) TYP 0: Prefix FVTIS: II G x ia II, IP67 Low Pilot 0, Polyarylamide onnector M (straight) + L and protection N5000 and N MO / 55506MO 55505MO / 506MO 55505MO / 506MO 4,5 54 0,5 0 x d certifi ed cable gland (on request) Three-core cable, length m 4 able gland for unarmoured cable with 7 to mm dia. sheath 6 onnector rotatable by 0 increments, Pg P (Ø 6-0 mm) 7 Screw type manual operator, suffi x MS Push type or screw type manual operator, suffi x MO xternal pilot air supply, / pipe 0 onnector rotatable by 0 increments, Pg 7P (Ø 6-7 mm) Push type manual operator, suffi x MO onnectable pilot exhaust port Non-connectable pilot exhaust port IMNSIONS (mm), WIGHT (kg) type prefix option level 55 55/ / / / / 55 weight () monostable bistable TNK P 7, ,7 77,7 - -,,7,7,6,05,5 0 ISS LP 46 6, ,5 45 7, - - 0,5,44,4 0,0,5,4 0 FS / FS LP - 4, , - 7, - - 0,,0,00 0,,,0 04 FVT LP - 4, , - 7, - - 0,,0,00 0,,,0 05 FL LP - 4, , - - 0,,,0 0,,, 06 PIS / PISIS UP - 4, , - 7, - - 0,,0,00 0,,,0 07 FSZN LP - 4, , - 7, - - 0,,0,00 0,,,0 0 FVTZN LP - 4, , - - 0,56,, 0,4,64,5 0 FSIS/FSIS LP - 4,5-6 -, - 7, - - 0,4,,0 0,4,, 0 FVTIS LP - 4, , - - 0,6,4,04 0,44,6,6 () Including coil(s) and connector(s). SSORIS Ø Ø / /4 / / 4,5-4 exhaust protector (stainless steel) ll leafl ets are available on: 007/R0 第 /0 页 4-40-

20 SRIS IMNSIONS (mm), WIGHT (kg) Supply rail (supplied with seals and banjo bolts, without mounting brackets) () supply rail for "n" valves supply rail with isolation valves (without mounting brackets) () - allows the isolation of one or more valves from the general pressure supply catalogue number supply rail catalogue number 7 G /4 NPT /4 for "n" valves G / (4) (4) vailable on request. Ø 5,7 G/4 5,5 series 55 number of valves type weight (kg) 0, mono/bistable 0,/,/,4,5/,,/,,/,7,5/,,/,5 04, mono/bistable 0,/,/,4,5/,,/,,/,7,5/,,/,5 05, mono/bistable 0,/0,6,7/,4,46/,,75/,,4/,5,4/,6,7/,4 06, mono/bistable 0,6/0,,4/,,4/,74,/,,0/,46,6/,,64/, 07, mono/bistable 0,/,/,4,5/,,/,,/,7,5/,,/,5 0, mono/bistable,5/,65,6/,6,/,77,46/,,/,7,0/4,0,57/4, 0, mono/bistable 0,/,0,/,46,54/,,5/,4,6/,,57/,4,/,66 0, mono/bistable,04/,,4/,7,7/,4,5/,5,6/,6,/,7,6/4, mounting brackets () series catalogue number () or () supply rail () mounting brackets (x) () () () TYP See pages 6 to Type 0 Type 04 Type 05 Type 06 Type 07 Type 0 Type 0 Type Ø 6,5 G /) ll leafl ets are available on: This mounting arrangement allows valves to be mounted in any of 4 positions. 7,5 7 7, ,5 7 6,5 PI G -- vailability, design and specifications are subject to change without notice. ll rights reserved. 007/R 第 0/0 页

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, /4 - / 4 4 / Series FTURS Series monostable spool valves /4 have TÜV certifi ed I 60 Functional

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 - / FTURS The monostable spool valves in conformity with I 650 Standard (00 route H version) have

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function, W/W) aluminium body, /4 - /2 4 4 2 2 4 4 2 4 4 2 2 4 4 2 2 2 /2 / Series - FTURS The monostable spool valves in conformity

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, /4 - / N 0 / Series 55 55 FTURS The monostable spool valves in conformity with I 650 Standard

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function, W/W) stainless steel body, /4 - /2 4 4 2 2 4 4 2 4 4 2 2 4 4 2 2 2 /2 / Series - FTURS The monostable spool valves

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 FTURS The monostable spool valves have TÜV-XID certified I 60 Functional Safety data and can be used up to SIL 4 (/TÜV)-SIL (/XID) The / and / solenoid operated spool valves have threaded port connections

More information

SOLENOID VALVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLENOI VLVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, / - / FETURES The monostable spool valves in conformity with IE 608 Standard (00 route

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NMUR style, / - / 0 / / Series - FETURES The monostable spool valves in conformity with IE 608 Standard

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4 to 1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4 to 1/2 FTURS The monostable spool valves have TÜV-XID certified I 60 Functional Safety data and can be used up to SIL 4 (/TÜV)-SIL (2-/XID) The spool valves /2 and / have threaded port connections ll the exhaust

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 - / FETURES The monostable spool valves in conformity with IE 508 Standard (00 route H version)

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 FTURS The monostable spool valves in conformity with I 60 Standard (200 route 2 H version) have TÜV ( series) and XID (- series) certified with integraty levels: SIL 2 for HFT = 0 / SIL for HFT = The /2

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NMUR style, / - / 0 / / Series - FETURES The monostable spool valves in conformity with IE 08 Standard

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid aluminium body, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid aluminium body, 1/4 to 1/2 FTURS SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid aluminium body, / to / SCO/JOUCOMTIC solenoid valves satisfy all relevant C irectives The monostable spool valves, series,

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2 SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, /4 to / 0 0 / Series 55 55-55 TURS SCO/JOUCOMTIC solenoid valves satisfy all relevant

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4 FETURES The monostable spool valves have TÜV certified IE 60 Functional Safety data and can be used up to SIL 4 ll the exhaust ports of this spool valve are connectable, providing better environmental

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

F650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F650HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 650H, -Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 00 psi ( to ) and 50 psi (4 to 4 ) 0% leakage, Long stem design allows for insulation, Valve face-to-face dimensions comply

More information

SOLENOIDS, COILS & ACCESSORIES Product Index

SOLENOIDS, COILS & ACCESSORIES Product Index SOLENOIDS, COILS & ACCESSORIES Product Index Description Series Page Coil identification Catalogue numbers of replacement coils SOLENOID OPERATORS Solenoid s, description and dimensions V1100-2/3 V1100-4..6

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 4, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 4, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6100HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6100H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

F680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F680HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 680H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

Products catalogue (I-P Edition)

Products catalogue (I-P Edition) Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established

More information

F6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F6125HD, 2-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc 6125H, 2-Way utterfly Valve Resilient Seat, 304 Stainless Steel isc Product eatures 200 psi (2 to 12 ) and 150 psi (14 to 24 ) 0% leakage, Long stem design allows for 2 insulation, Valve face-to-face dimensions

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

P2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B050, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating and cooling coils, and fan coil unit heating or cooling coils. Some other common applications

More information

B2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem

B2150VB-055, 1-1/2, V Ball Control Valve Hardened Chrome Plated Carbon Steel Body, Stainless Steel Ball and Stem 50V-055, -/, V all ontrol Valve Hardened hrome Plated arbon Steel ody, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive shut-off,

More information

2-way pilot operated solenoid valves for water, hot water and steam

2-way pilot operated solenoid valves for water, hot water and steam 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8658/GB NEW Also available with ATEX Explosion-proof electrical parts Technical specifications General description Applications

More information

B212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem

B212, 2-Way, Characterized Control Valve Stainless Steel Ball and Stem , -Way, haracterized ontrol Valve Stainless Steel all and Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating or cooling coils. Some

More information

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013 4-Way Servo Valve Model 4 WS. 2 E. 16..., (Series 2X) with Mounting attern to DIN 24 3 or CETO R 11 H Size 16... 40 SI (31 bar)... 3 GM (0 L/min) R 29 91/06.98 R 29 91/06.98 Replaces: 0.94 2 stage servo

More information

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11,

More information

B6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

B6400VB-350, 4, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem 6400V-350, 4, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2050B005, 1/2, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2050005, 1/2, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

P2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends

P2075B100-P, 3/4, Pressure Independent Valve Chrome Plated Brass Ball and Brass Stem, NPT Female Ends P2075100-P, 3/4, Pressure Independent Valve hrome Plated rass all and rass Stem, NPT emale nds pplication The Pressure Independent haracterized ontrol Valve is typically used in air handling units on heating

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

Technical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m

Technical data. Standards: IEC/EN thermoplastic Protection class: IP 67 to EN Termination: cable LiYY 2 x 0.25 mm 2, length 1 m B 6,5 3,5 4 44 33,5 13 4 00 Flat design on-contacting principle 1 Reed contact ctuating distance up to 60 mm depending on actuating magnet and version ctuating surface marked by protrusion Pre-wired cable

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration Siemens G 200 Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level

More information

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc F80HD, 3, 3-Way utterfly Valve Resilient Seat, 304 Stainless Steel Disc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Precision Thermistor Sensors

Precision Thermistor Sensors Precision Thermistor Sensors For Laboratory Applications ON-400 Series U For Use in Laboratory or Other High-Accuracy Applications U Rugged Construction Can Be Used for Short Term Water and Soil Readings

More information

B6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem

B6300VB-207, 3, V Ball Control Valve Carbon Steel Body, Hardened Chrome Plated, Stainless Steel Ball and Stem 6300V-207, 3, V all ontrol Valve arbon Steel ody, Hardened hrome Plated, Stainless Steel all and Stem Product eatures ast quarter turn open or closed operation, Stainless steel ball and stem, Positive

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level transmitter

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. & 4 Wire Self ompensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. FETURES S.S. 1L Face Material c/w Tri-lamp Mtg. Base Simple push-button calibration (ccurate) Output 4-20 m / 20-4

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

RECEIVER SECURYFILL IV

RECEIVER SECURYFILL IV RIVR SURYFILL IV Q S ISO 00 RTIFI FIRM INSTLLTION S GUI MX ROHSTR GUGS INTRNTIONL S.. Z.I. WVR NOR - v.lavoisier, - -00 WVR (elgium) Tel. ++ (0)/4.. - Fax ++ (0)/.. 0/0 Rev. Optoelectronic Transmitter

More information

Proportional Directional Control Valves Nominal sizes 16 and 25

Proportional Directional Control Valves Nominal sizes 16 and 25 Proportional Directional Control Valves Nominal sizes 16 and 25 Pilot operated, electrically adjustable Interface acc. to DIN 24 340 and ISO 4401 PN [p max. ] = 315 bar 7502968.06.01.06 Description Design

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

lif flex CirCUit ConneCtor 2.54mm [.100"] CeNTerliNe 1.25mm [.049"] CeNTerliNe 1.00mm [.

lif flex CirCUit ConneCtor 2.54mm [.100] CeNTerliNe 1.25mm [.049] CeNTerliNe 1.00mm [. dam Technologies, Inc. INTRODUTION: dam Tech P Dual Series Port D-Sub Flexible onnectors Printed ircuit provide (FP) the and means Flexible to increase Flat able I/O (FF) without connectors utilizing are

More information

The transducer component converts the measured signal and displays the actual value.

The transducer component converts the measured signal and displays the actual value. Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E

Profibus-PA. Profibus-PA. Process Automation. Over-Molded Cables Receptacles Field Wireables Accessories. UL File #: E Profibus-PA Process Automation Over-Molded Cables Receptacles Field Wireables Accessories U File #: E9 PROFIBUS (Process Field Bus) is a standard for field bus communication in automation technology. The

More information

INTERMEDIATE METAL CONDUIT

INTERMEDIATE METAL CONDUIT PRODUCT GUIDE 08 CONDUIT PIPES CONDUIT FITTINGS FITTINGS FOR FLEXIBLE CONDUITS METALLIC ELECTRICAL BOXES AND COVERS CONDUIT BODIES WEATHERPROOF BOXES AND COVERS CHANNELS & SUPPORTS METAL ENCLOSURES CHANNELS

More information

Base Mounted Plug-in Unit

Base Mounted Plug-in Unit For details about certified products conforming to international standards, visit us at www.smcworld.com. 000 Plug-in Unit SI unit COM N V V C C C6 M CM 6 B B B6 B M 000 Manifold model Plug-in unit Stations

More information

Operation. LEVEL Transmitters

Operation. LEVEL Transmitters Ultrasonic compact level transmitters for liquids echork GNRL DSCRIPION he high performance level transmitters are based on NIVLCO s 30 years of experience with ultrasonic level measurement. Whether for

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Main features. Operation. LEVEL Transmitters

Main features. Operation. LEVEL Transmitters Non-contact microwave level transmitters pilotr GNRAL DSCRIPTION The 25 GHz (-band) Pulse Radars are regarded as the most progressive non-contact level transmitters of the industrial process automation

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350 Technical brochure Features Designed for use in severe maritime environments For medium and ambient temperatures

More information

MODUBLOC MB SE SERIES

MODUBLOC MB SE SERIES The MODUBLOC MB SE series of burners are characterised by a monoblock structure that means all necessary components can be combined in a single unit, making installation easier and faster. The series covers

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

NEW. 7321B 7322B Series. 2-way pilot operated solenoid valves for water, hot water and steam

NEW. 7321B 7322B Series. 2-way pilot operated solenoid valves for water, hot water and steam 7321B 7322B Series 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8659/GB NEW Also available with ATEX G & D Explosion-proof electrical parts Technical specifications General

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information