2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
|
|
- Damon Barrett
- 5 years ago
- Views:
Transcription
1 SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes important points of caution for safe use of this product in potentially explosive atmosphere. Please read this manual carefully before installing and operating the product. MODEL NUMBER IDENTIFICATION ) SAFETY APPROVAL 0 : None : FM intrinsically safe 5 : FM nonincendive ) LCD DISPLAY : With ) OPTIONS -X : Special specification ) SAFETY APPROVAL * 0 : None : FM intrinsically safe : FM explosion-proof 5 : FM nonincendive ) LCD DISPLAY : With ) WIRING CONDUIT * : / NPT : M0 x.5 : PG.5 ) MOUNTING BRACKET : With 5) OPTIONS /S : Stainless steel enclosure -X : Special specification Model No. B6U Model No. B6U-B 5 *. Confirm selectable combination of approval and wiring conduit types in the table below. Selectable Wiring Conduits Specific to Each Approval N marked combinations are not selectable. APPROVAL WIRING CONDUIT 0 5 Y Y Y Y Y Y N Y Y N N N MANUFACTURED DATE CODE IDENTIFICATION The manufactured year and month can be identified by the serial number described on the specification label. Serial No. Y M xxxxxx YEAR : 0 A : 00 : 0 5 : 05 B : 0 : 0 : : : : : : 9 : 09 U : 00 9 : 09 MONTH (year) (year) A : January M : January B : February N : February C : March P : March : : : : L : December Y : December WARNING Explosions could result in death or serious injury: The enclosure cover must be fully engaged to meet explosion-proof/flameproof requirements. Do not remove the enclosure cover in explosive atmospheres when the circuit is alive (except IS models). Do not connect or disconnect the LCD module in explosive atmosphere when the circuit is alive. When the LCD is not installed, covers shall instead be fitted at the open connectors. Before you remove the unit or mount it, or before you connect or disconnect the wiring, turn off the power supply and the input signal for safety. Do not disconnect unless the area is known to be non-explosive. Take care not to generate mechanical spark when accessing to the instrument and peripheral devices in hazardous locations. Do not apply physical impact or friction on the B6U-B enclosure. Whenever you need to measure voltage across the terminals or apply a simulated input signal to the terminals, make sure that there is no danger of explosion in the atmosphere. Before connecting a HART communicator in an explosive atmosphere, make sure the instruments in the loop are installed in accordance with intrinsically safe field wiring practices. Verify the certification of the product described on the specification label on the product. Verify that the operating atmosphere of the transmitter is consistent with the appropriate hazardous locations certifications. Verify that the environmental temperature is within the temperature class required for the area. Failure to follow these installation guidelines could result in death or serious injury: Make sure only qualified personnel perform the installation. The instrument modification or parts replacement by other than authorized representative of M-System Co., Ltd. is prohibited and will void the approval of Factory Mutual Research Corporation. The FM approval of model B6U-B is applied to the combination of the outdoor enclosure and the transmitter. The transmitter must not be separated or replaced. Phone: 8(6) Fax: 8(6) info@m-system.co.jp EM-75-E Rev. P. / 5
2 B6U / B6U-B SAFETY FEATURES & CAUTIONS INTRINSICALLY SAFE APPROVAL Model B6U Approval Class I, Division, Groups A, B, C and D Class I, Zone 0, AEx ia IIC Model B6U-B Approval Class I, Division, Groups A, B, C and D Class II, Division, Groups E, F and G Class I, Zone 0, AEx ia IIC Enclosure Rating: NEMA X Entity Parameters Ui (Vmax) = 0V DC Uo (Voc) = 6.V DC Ii (Imax) = 96mA DC Io (Isc) = 0mA DC Pi (Pmax) = 70mW Po = 8mW Ci = 0 µf Co (Ca) = 0 µf Li = 0 mh Lo (La) = 0 mh Temperature Code: T, T5, T6 Ambient Temperature: -0 to 80 C (T) -0 to 65 C (T5) -0 to 50 C (T6) A safety barrier must be installed between the unit and its power supply. Refer to Installation Diagram attached at the end of this manual when selecting a safety barrier. The power supply and the safety barrier must be located in a non-hazardous area. The wiring method must be in accordance with the Entity Parameters described in this manual. Be sure to earth the unit (model: B6U-B). When metal particles are present in the air, install the model B6U inside the Outdoor Enclosure (model 6BX-E) provided separately. For installing the B6U in an environment with a high relative humidity exceeding 0 to 95% RH or in a condensing atmosphere, install the unit inside the Outdoor Enclosure (model 6BX-E) provided separately. NONINCENDIVE APPROVAL Model B6U Approval Class I, Division, Groups A, B, C and D Class I, Zone, Group IIC Model B6U-B Approval Class I, Division, Groups A, B, C and D Class II, Division, Groups F and G Class I, Zone, Group IIC Enclosure Rating: NEMA X Nonincendive Field Wiring Parameters Ui (Vmax) = 0V DC Uo (Voc) = 6.V DC Ii (Imax) = 96mA DC Io (Isc) = 0mA DC Pi (Pmax) = 70mW Po = 8mW Ci = 0 µf Co (Ca) = 0 µf Li = 0 mh Lo (La) = 0 mh Temperature Code: T, T5, T6 Ambient Temperature: -0 to 80 C (T) -0 to 65 C (T5) -0 to 50 C (T6) The general purpose equipment connected to this unit must be located in non-hazardous area. Refer to Installation Diagram attached at the end of this manual. The wiring method must be in accordance with the Nonincendive Field Wiring Parameters described in this manual. Be sure to earth the unit (model: B6U-B). When metal particles are present in the air, install the model B6U inside the Outdoor Enclosure (model 6BX-E) provided separately. For installing the B6U in an environment with a high relative humidity exceeding 0 to 95% RH or in a condensing atmosphere, install the unit inside the Outdoor Enclosure (model 6BX-E) provided separately. Model B6U-B EXPLOSION-PROOF and DUST-IGNITION PROOF APPROVAL Explosion-Proof Class I, Division, Groups B, C and D Dust-Ignition Proof Class II, Division, Groups E, F and G Enclosure Rating: NEMA X Temperature Code: T6 Ambient Temperature: -0 to 80 C (T6) All wiring shall comply with National Electrical Code ANSI/NFPA 70 and Local Electrical Codes. SEAL ALL CONDUITS WITHIN 8 INCHES. Use suitable heat resistant cable for ambient temperatures 70 C Before wiring, make sure there is no danger of explosion in the atmosphere. Before opening the enclosure, wait at least for 60 seconds after the power is removed. The cable entry device and stopping plugs for unused apertures shall be of a certified explosion-proof type, suitable for the conditions of use and correctly installed. The cable entry conduit is / NPT threaded. Five or more cable entry threads must be engaged. Squeeze the cable entry and stopping plug into the conduit with the proper tool. Before turning the power supply on, be sure to close the enclosure cover tightly. Be sure to earth the unit. For external earthing or bonding connection a cable lug shall be used so that the conductor is secured against loosening and twisting and that contact pressure is maintained. Phone: 8(6) Fax: 8(6) info@m-system.co.jp EM-75-E Rev. P. / 5
3 INSTALLATION DIAGRAM for FM INTRINSICALLY SAFE MODEL B6U / B6U-B Class I, II, III, Division Groups A, B, C, D, E, F and G Class I, Zone 0, IIC Class I, Division B6U-B B6U Groups A, B, C and D Class I, Zone 0, IIC Safety Barrier PS PS ENTITY PARAMETERS Power Supply (Terminals and ) Maximum Input Voltage Ui (Vmax) : 0 V Maximum Input Current Ii (Imax) : 96 ma Maximum Input Power Pi (Pmax) : 0.7 W Maximum Internal Capacitance Ci : 0 µf Maximum Internal Inductance Li : 0 mh Sensor Circuit (Terminals to ) Maximum Output Voltage Uo (Voc) : 6. V Maximum Output Current Io (Isc) : 0 ma Maximum Output Power Po (Pmax) : 8 mw Maximum External Capacitance Co (Ca) : 0 µf Maximum External Inductance Lo (La) : 0 mh For the sensor circuit, these entity parameters must be taken account when installed. Installation requirements between temperature transmitter and safety barrier: Uo or Voc Ui or Vmax Io or Isc Ii or Imax Po or Pmax Pi or Pmax Ca Ci C cable La Li L cable Uo, Voc, Io, Isc, Po, Pmax, Ca and La are parameters of the safety barrier. : : : : 5 : 6 : 7 : The safety barrier must be approved by FM. Input voltage of the safety barrier must be less than 50 Vrms/Vdc. Installation should be in accordance with ANSI/ISA RP.6 Installation of Intrinsically Safe Systems for Hazardous (Classified) Locations and the National Electrical Code (ANSI/NFPA 70). The intrinsically safe sensor connected to sensor circuit of the B6U or B6U-B must be approved by FM or simple apparatus. (a device which will neither generate nor store more than.v, 0.A, 5mW or 0µJ, e.g. switches, thermocouples, LED s or RTD s) Do not alter drawing without authorization from FM. Conduit seal be to used on the B6U-B for Class II and III. FM approved models are shown in Page. Phone: 8(6) Fax: 8(6) info@m-system.co.jp EM-75-E Rev. P. / 5
4 B6U / B6U-B INSTALLATION DIAGRAM for FM NONINCENDIVE MODEL Class I, II, Division Groups A, B, C, D, F and G Class I, Zone, IIC Class I, Division B6U-B B6U Groups A, B, C and D Class I, Zone, IIC General Purpose Equipment PS PS NONINCENDIVE FIELD WIRING PARAMETERS Power Supply (Terminals and ) Maximum Input Voltage Ui (Vmax) : 0 V Maximum Input Current Ii (Imax) : 96 ma Maximum Input Power Pi (Pmax) : 0.7 W Maximum Internal Capacitance Ci : 0 µf Maximum Internal Inductance Li : 0 mh Sensor Circuit (Terminals to ) Maximum Output Voltage Uo (Voc) : 6. V Maximum Output Current Io (Isc) : 0 ma Maximum Output Power Po (Pmax) : 8 mw Maximum External Capacitance Co (Ca) : 0 µf Maximum External Inductance Lo (La) : 0 mh For the sensor circuit, these nonincendive field wiring parameters must be taken account when installed. Installation requirements between temperature transmitter and general purpose equipment: Uo or Voc Ui or Vmax Io or Isc Ii or Imax Po or Pmax Pi or Pmax Ca Ci C cable La Li L cable Uo, Voc, Io, Isc, Po, Pmax, Ca and La are parameters of the general purpose equipment. : : : : 5 : 6 : When the connection between B6U/B6U-B and general purpose equipment is carried out with nonincendive field wiring parameters, the general purpose equipment must be approved by FM. Installation should be in accordance with ANSI/NFPA 70. Do not alter drawing without authorization from FM. The nonincendive sensor connected to sensor circuit of the B6U or B6U-B must be approved by FM or simple apparatus. (a device which will neither generate nor store more than.v, 0.A, 5mW or 0µJ, e.g. switches, thermocouples, LED s or RTD s) Conduit seal be to used on the B6U-B for Class II and III. FM approved models are shown in Page. Phone: 8(6) Fax: 8(6) info@m-system.co.jp EM-75-E Rev. P. / 5
5 INSTALLATION DIAGRAM for FM EXPLOSION-PROOF MODEL B6U / B6U-B NRTL Explosion-proof Sensor Assembly * Explosion-proof Enclosure Division Transmitter PS PS * * ELECTRICAL DATA Power Supply ( and ) Supply Voltage : to 8 V Output Current : to 0 ma (Burnout Current : ma) Sensor Circuit ( to ) Input Signal :.0 V max * : All wiring shall comply with National Electrical Code ANSI/NFPA 70 and Local Electrical Codes. SEAL ALL CONDUITS WITHIN 8 INCHES. * : Sensor assembly must be approved for appropriate hazardous location by a certification organization recognized as NRTL. Phone: 8(6) Fax: 8(6) info@m-system.co.jp EM-75-E Rev. P. 5 / 5
MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationThie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:
Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.
More informationAH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models AH71, AH72, and AH73 are
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationHT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models HT880 and HT885 are 2-wire temperature
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationInstallation guide 873 SmartRadar Control Unit & Antenna Unit
Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl
More informationUser's Manual Model SE14 Magnetic Flow Converter
User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationMCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol
SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationInstallation guide 877 FDI Field Display & Interface
Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters
Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationD1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater
D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationEJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.
User s Manual EJX and EJA-E Series Differential Pressure and Pressure s Installation Manual Contents 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More informationYTA Series Temperature Transmitters (Hardware) [Style: S3]
User s Manual YTA Series Temperature Transmitters (Hardware) [Style: S3] 4th Edition YTA Series Temperature Transmitters (Hardware) 4th Edition CONTENTS. Preface... - Notes on the User s Manual...- Notes
More informationInstallation guide 854 XTG Level Gauge
Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationProduct manual wire programmable RTD transmitter
Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001
More informationQN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO
QUARTZ with -0 ma Position Transmitter or Potentiometer (QXO, QNO, QXBO, QNBO, QXO, QNO, QXO, QNO ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationESSENTIAL INSTRUCTIONS Read this page before proceeding!
Instruction Sheet LIQ_MAN_ABR_/Rev.G January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical,
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationUser s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).
User s Manual Model DY Vortex Flowmeter (Integral Type, Remote Type) Model DYA Vortex Flow Converter (Remote Type) FOUNDATION Fieldbus Communication Type Manual Change No.14-013V-E Please use the attached
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationInstallation guide 970 SmartRadar ATi
Installation guide 970 SmartRadar ATi July 2008 Part no. 4416.717 Rev. 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website
More informationINSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D
D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters
Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationYTA610 and YTA710 Temperature Transmitter (Hardware)
User s Manual YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition 1 YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...1-1
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More information[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011
Quick Installation Guide Temperature Transmitter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications End www.rosemount.com
More informationUser s Manual EJX118A and EJX438A Diaphragm Sealed Differential Pressure and Pressure Transmitters
User s Manual EJX118A and EJX438A Diaphragm Sealed Differential Pressure and Pressure Transmitters 6th Edition i EJX118A and EJX438A Diaphragm Sealed Differential Pressure and Pressure Transmitters Contents
More informationMid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationMobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA
Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for
More informationControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD
Product Information Package PIP-CW ISProx Jul., 007 ControlWave ISProx Board ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD For ControlWave EFM/GFC/GFC Correctors Remote Automation Solutions
More informationCertificate of Conformity
Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated;
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationOperating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationJM Enclosure Dimensions (in mm)
ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with
More informationModel LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR
DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 203-368-6751 FAX 203-368-3747 http://www.devarinc.com e-mail: info@devarinc.com Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR R Manual No. 990649
More informationRosemount 753R Remote Web Based Monitoring Indicator
Rosemount 753R Remote Web Based Monitoring Indicator Product Discontinued February 2010 Start Overview Rosemount 753R with Integral 3051S Pressure Transmitter Rosemount 753R with Remote Mounted HART Transmitter
More informationUser s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A 12th Edition i Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
More informationUser s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438
User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438 12th Edition i Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438 Contents
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationUser s Manual Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E
User s Manual Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E 13th Edition i Flange Mounted Differential Pressure Transmitters EJX210A and EJA210E Contents 13th Edition 1. Introduction...
More informationEN Series Installation Manual
Pub # 007revG EN Series Installation Manual Approval Agency Controlled Document. No Changes Authorized Without Prior Agency Approval StoneL 7 US Highway 9 Fergus Falls, MN 7 USA Telephone: (8) 79-77 Fax:
More informationUser s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438
User s Manual Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438 8th Edition i Diaphragm Sealed Differential Pressure and Pressure Transmitters EJ 118 and EJ 438 Contents
More informationInstallation guide 970, 971 and 973 series SmartRadar
Installation guide 970, 971 and 973 series SmartRadar August 2008 Part no. 4416.719 Rev. 1 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More informationProduct Manual wire HART transmitter
Product Manual 6335 2wire HART transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 6335V111UK From serial no.: 150951186 6 Product
More informationRosemount 5600 Series Radar Level Transmitter with HART and Foundation fieldbus protocol
Radar Level Transmitter with HART and Foundation fieldbus protocol Start Step : Mount the Transmitter Step 2: Connect Wiring and Power Up Step : Configure the Transmitter Product Certifications Confirm
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationRosemount 5400 Series Radar Level Transmitter
Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights
More informationHumidity Sensor/Transmitter Assembly
Humidity Sensor/Transmitter Assembly Wall/Duct Space Outside Air (OSA) Overview Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier
Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationWhite Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005
White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49
More informationCertificate of Compliance
FF01 Certificate of Compliance Certificate: 1294176 Master Contract: 209996 Project: 1294176 Issued to: Seika Mikrosystemtechnik GmbH Ellharter StraBe 10 D-87435 Kempten GERMANY The products listed below
More informationUser s Manual Model EJA510A and EJA530A Absolute Pressure and Gauge Pressure Transmitters [Style: S2]
User s Manual Model EJA510A and EJA530A Absolute Pressure and Gauge Pressure Transmitters [Style: S2] 9th Edition i Model EJA510A and EJA530A Absolute Pressure and Gauge Pressure Transmitters [Style: S2]
More informationGeneral Specifications
General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless
More informationGeneral Specifications
General Specifications YTA0, YTA0 Temperature Transmitter [Style: S] The YTA0 and YTA0 are the highly accurate temperature transmitters that accept Thermocouple, RTD, ohms or DC milivolts inputs and converts
More informationA9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters
THIS DRAWING IS PROPERTY OF AND PROPRIETARY TO EMERSON. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED NOR DISCLOSED TO ANYONE EXCEPT THOSE REQUIRING ITS USE FOR EMERSON AUTHORIZED
More informationUser s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2]
User s Manual Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure Transmitters [Style: S2] 18th Edition i Model EJA118W, EJA118N and EJA118Y Diaphragm Sealed Differential Pressure
More informationRosemount 3101, 3102, and 3105
Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More informationUser s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
User s Manual Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A 11th Edition i Absolute Pressure and Gauge Pressure Transmitters EJ 510, EJ 530, EJX610A and EJX630A
More informationProcessMaster / HygienicMaster
SM/FEP300/FEH300/FM/CSA-EN ProcessMaster / HygienicMaster FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual Standards
More information600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet
Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration
More informationYVP110 Advanced Valve Positioner
User s Manual YVP110 Advanced Valve Positioner 10th Edition i YVP110 Advanced Valve Positioner 10th Edition CONTENTS Introduction...viii Notes on the User s Manual... viii For Safe Use of Product... viii
More information600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)
Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically
More informationQuick Start Guide , Rev CA April Rosemount 4088A MultiVariable Transmitter. with Modbus Output Protocol
00825-0100-4088, Rev CA Rosemount 4088A MultiVariable Transmitter with Modbus Output Protocol Safety messages NOTICE This guide provides basic guidelines for the Rosemount 4088 MultiVariable Transmitter.
More informationPRODUCT SPECIFICATION AND MODEL SELECTION GUIDE
XYR 5000 Wireless Temperature Transmitters WT530 34-XY-03-02 09/2006 PRODUCT SPECIFICATION AND MODEL SELECTION GUIDE Function The WT530 Temperature Transmitter is part of the XYR 5000 family of wireless
More informationFisher 646 Electro Pneumatic Transducer
Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere
More informationInstruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams
Instruction MI 019-175 October 2000 I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams MI 019-175 October 2000 Intrinsically Safe Connection Diagrams If your Model 83.-D/-T
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationAlphaline Temperature Transmitters
Alphaline Temperature Transmitters Accepts RTD and thermocouple inputs Available with an integral meter Dual compartment housing provides the highest reliability in harsh industrial environments Offers
More information