JM Enclosure Dimensions (in mm)
|
|
- Virgil Perry
- 6 years ago
- Views:
Transcription
1 ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with termination points for connecting switches/sensors, as well as outputs to operate ultra low power (iezo) devices such solenoid valves and relays. Inputs and Outputs - Two () Discrete Inputs - Two () Discrete Outputs Features - LED input displays for Inputs & - Date of Last Service - re-determined output Fail State (See age detailed wiring instructions) JM Enclosure Dimensions (in mm) Standard Enclosure Switched Enclosure Enclosure w/cyclone Valve Ø StoneL One StoneL Dr 67 US Hwy 9 Fergus Falls, MN 67 USA Approval Agency Controlled Document. No Changes Authorized Without rior Agency Approval 00 StoneL Corporation Telephone: Toll Free: Fax: sales@stonel.com Website:
2 JM M9 JM Model Options Example: JMM9GE Function Solenoid I/O Module ( DI/ DO), F/Fieldbus (H) No Solenoid (only w/ Solenoid,A,G) ilot Type Brass SS -Solenoid -ostn,-way H B -IS iezo -ostn,-way G A -Solenoids -ostn,-way L E Enclosure C Clear Cover E Epoxy Coated Aluminum ub #0revB age Conduit Entries () / NT N () / NT 6 () M0 M () M0 9 () / NT T () / NT General Specifications Operating Life Unlimited Materials of Construction Housing and Cover Marine grade anodized aluminum epoxy coating Clear Cover Lexan olycarbonate Elastomer Seals Buna-N Fasteners Stainless Steel Warranty Complete Assemblies Two Years Lexan is a registered trademark of General Electric Corporation. Temperature Range -0 to +80 C (-0 to 76 F) Enclosure rotection NEMA, X & 6; I67 Hazardous Area Ratings Intrinsic Safety (FISCO) Class I, Div. and, Groups A,B,C,D Class II, Div. and, Groups E,F,G Explosion roof (Aluminum Cover) Class I, Div. and, Groups B,C,D Class II, Div. and, Groups E,F,G Non-incendive (Clear Cover) Class I, Div., Groups A,B,C,D Class II, Div., Groups E,F,G (Not all units carry approvals, consult factory) Mounting Instructions Mounting The JM Enclosure. Locate the position where the JM enclosure will be mounted. Ensure that there is sufficient room to operate the disconnect switch levers and to remove the cover.. Attach the JM enclosure to a wall or other stationary flat surface using the mounting holes provided.. Secure the cover until hand tight Attaching Conduit and Fittings. Conduit entries are provided for the convenient attachment of threaded conduit and threaded conduit fittings. Attach threaded fittings and conduits securely.. Follow all applicable NEC codes and other regulations. Installing & Removing Cover. To insure NEMA, X. 6 and hazardous location ratings are maintained the cover must be completely closed and the O-Ring sealed to keep out water.
3 Specifications Communication rotocol: Configuration: Function Blocks Indication Voltage: Output Voltage: Max. Output Current: Current Draw: JMM9 Input/Output Module Specifications ub #0revB age Foundation Fieldbus (H) () Discrete Inputs for low power dry contact switches capable of operating at 6.VDC or solid state N capable of operating at 6. VDC () Discrete Outputs for bus powered discrete devices that operate at ultra low power such as iezo solenoid valves and relays. Limited 6. VDC DI; DO Input = Red LED Input = Green LED 9- VDC (Bus Voltage) VDC 6mA Standard Channel Assignments Channel (DI) - Discrete Input (Red LED); Channel (DI) - Discrete Input (Green LED); Channel (DO) - Discrete Output (OUT ); Channel (DO) - Discrete Output (OUT ); Special Channel Assignments Channel 8 (DO) - Discrete Output (OUT ) with state report from Discrete Input (READBACK_D) Channel 9 (DO) - Discrete Output (OUT ) with state report from Discrete Input (READBACK_D) Valve Control Single Block Mode Channel 0 (DO) - Discrete Output (OUT ) with state report Discrete Inputs & (READBACK_D): READBACK_D Values: 0 = None = Discrete Input is True = Discrete Input is True = Both Discrete Inputs & are True
4 Wiring Diagram and Installation Notes ub #0revB age RED LED RTN FOR WIRE N SENSORS SIM JMR SIM JMR DI GRN (-) DI RED (-) OUT - OWER (+) OUT + OUT - OUT + FB - FB + GREEN LED WIRING NOTES:. FOUNDATION Fieldbus bus communications connection points.. Bus powered Discrete Input connection points for low power dry contacts capable of operating at 6.VDC or solid state N sensors capable of operating at <ma and 6.VDC. Red LED is local indication of discrete input DI RED on/off status and the Green LED for DI GRN on/off status. NOTE: The Discrete Inputs (DI) are not galvanically isolated from the FOUNDATION signal wires. Therefore, the DI connections should not be attached to ground. If the cable runs to the DI s are long or can be exposed to electrical noise, external Opto-isolators on the DI wires may be needed to provide isolation.. Connection point for the return of wire N sensors. (See Note ). Connection points for Bus powered discrete outputs to operate ultra low power (iezo) devices such solenoid valves and relays. Limited 6. VDC. For models with single coil pneumatic valves, coil is pre-wired to Output (Channel ). For models with dual coil pneumatic valves, coil one is pre-wired to Output (Channel ) and coil two is pre-wired to Output (Channel ).. These connection points not used by the consumer. (See pages 6&7 for Intrinsically Safe (FISCO) installations)
5 The Cyclone neumatic Valve is a pilot operated -way spring return which may be used for single and doubleacting actuators. It features a direct-acting solenoid with manual override for the pilot. The porting is sized to tolerate contaminant's up to 0 microns in size which may be found in conventional pneumatic systems. The Cyclone neumatic Valve is O-ring sealed on the Junction Module (JM) enclosure to maintain it's temporary submergibility rating. Cyclone neumatic Valve Specifications neumatic orting Solenoid ilot Valves ub #0revB age Manual Overrides VDC ilot ower....8 Watts Current draw... 7 Temperature C to +0 C Filtration Requirements... 0 Microns ressure Range... to 0 SI Cv (0.7 Kv) iezo ilot Current draw... Temperature C to +60 C Filtration Requirements... 0 Microns ressure Range... to 0 SI Cv (0.7 Kv) orting... / NT Valve Body Material brass or 0 Stainless Operating Life... million cycles Manual Overrides: One internal momentary and One external locking. A E(A) Latching Manual Override B Variable Speed Adjustment: Each cylinder port is internally ported to a unique exhaust port (EA for exhaust of port A and EB for exhaust of port B). To vary actuator speed flow restrictors may be added to EA or EB to reduce exhaust flow and actuator speed in either direction. Single-Acting Vent to Atmosphere or Refresh: Exhaust (EA or EB) and secondary ports (A or B) may be blocked for single-acting operation with the actuator venting directly to atmosphere. Alternatively, the secondary port may be plumbed to the actuator supplying air to the spring side of the actuator and preventing it from ingesting atmospheric contaminant's. - ressure ort (/ " NT) A - Cylinder ort (/" NT) B - Cylinder ort (/" NT) E(A) - Exhaust for Cylinder ort A (/" NT) E(B) - Exhaust for Cylinder ort B (/" NT) Single Coil: way with neumatic pilot Schematics B E(B) A EA EB Dual Coil: Shuttle iston with neumatic pilots ( osition Valve with position detente A B E
6 Intrinsic Safety (FISCO) Hazardous Location Installation Diagram FISCO Concept ub # 0revB age 6 The FISCO Concept allows the interconnection of intrinsically safe apparatus to associated apparatus not specifically examined in such combination. The criterion for such interconnection is that voltage (Vmax), the current (Imax), and the power (i), which intrinsically safe apparatus can receive and remain intrinsically safe, considering faults, must be equal to or greater than the voltage (Uo, Voc, Vt), the current (Io, Isc, It), and the power (o) which can be provided by the associated apparatus (supply unit). In addition, the maximum unprotected residual capacitance (Ci) and inductance (Li) of each apparatus (other than the terminators) connected to the Fieldbus must be less than or equal to nf and 0μH respectively. In each I.S. Fieldbus segment only one active source, normally the associated apparatus, is allowed to provide the necessary power for the Fieldbus system. The allowed voltage (Uo, Voc, Vt) of the associated apparatus used to supply the bus must be limited to the range of V d.c. to V d.c. All other equipment connected to the bus cable has to be passive, meaning that the apparatus is not allowed to provide energy to the system, except to a leakage current of 0μA for each connected device. Separately powered equipment needs a galvanic isolation to insure that the intrinsically safe Fieldbus circuit remains passive. The cable used to interconnect the devices must comply with the following parameters: Loop resistance R : - 0 ohm/km Inductance per unit length L : 0. - mh/km Capacitance per unit length C : 80-00nF/KM C = C line to line + ½ C line to shield, if both lines are floating with respect to shield or C = C line to line + C line to shield, if one line is connected to shield Trunk Length: < 000 meters Spur Length: < 0 meters Splice Length: < meters FM Approved line terminators must be used on each end of the trunk cable that have the following parameters: R = ohms C = μf (See age 7 for Installation Diagram and Notes)
7 Intrinsic Safety (FISCO) Hazardous Location Installation Diagram JMM9 Intrinsically Safe (FISCO) installation: ub # 0revB age 7 HAZARDOUS (CLASSIFIED) LOCATION IS (FISCO) Cl I,II,III Div, Groups A,B,C,D,E,F,G NON-HAZARDOUS (SAFE AREA) LOCATION 6 JMM9 Enclosure FM/CSA Approved Control Equipment FM/CSA Approved Termination FM/CSA Approved Fieldbus Device n suitable for FISCO FM/CSA Approved Fieldbus Device suitable for FISCO FB + FB - See page Wiring Diagram for Terminal Identifiers INSTALLATION NOTES: JMM9 Entity arameters (FISCO): Ui (Vmax) = 0 Vdc; Ii (Imax) = 80 ma ; Ci = 0.0 nf; Li = 0.0 mh; i =. W 6. Installation shall be in accordance with ANSI/ISA RA.6.0, ANSI/NFA 70, and the National Electrical Code or in accordance with the Canadian Electric Code.. Dust-tight conduit seal must be used when installed in Class II and Class III environments or where Ingress rotection of I67 is required.. Control equipment must be FM or CSA Approved Associated Apparatus suitable for FISCO.. Control equipment connected to FISCO barrier must not use or generate more than 0Vrms or Vdc.. Resistance between FISCO Intrinsically Safe Ground and earth ground must be less than.0 Ohm. 6. Devices connected to the Discrete Inputs and Discrete Outputs must be suitable for FISCO. (Optional solenoid valve with piezo electric coil is suitable for FISCO). 7. Substitution of components may impair hazardous location safety. 8. Approval Agency controlled Installation Diagram. No revision to diagram allowed without prior Factory Mutual or Approval Agency authority.
Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:
Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationEN Series Installation Manual
Pub # 007revG EN Series Installation Manual Approval Agency Controlled Document. No Changes Authorized Without Prior Agency Approval StoneL 7 US Highway 9 Fergus Falls, MN 7 USA Telephone: (8) 79-77 Fax:
More informationQN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO
QUARTZ with -0 ma Position Transmitter or Potentiometer (QXO, QNO, QXBO, QNBO, QXO, QNO, QXO, QNO ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationIntrinsic Safety Control Drawing
s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationWhite Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005
White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationAH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models AH71, AH72, and AH73 are
More informationEJX and EJA-E Series Differential Pressure and Pressure Transmitters Installation Manual. Contents 1. Introduction. 3. Installation. 5.
User s Manual EJX and EJA-E Series Differential Pressure and Pressure s Installation Manual Contents 1. Introduction 1.1 For Safe Use of Product...2 1.2 Warranty...3 1.3 ATEX Documentation...4 2. Handling
More informationFieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004
Fieldbus Solutions & Network Topologies ISA Exhibition Toronto May 12, 2004 Fieldbus Solutions During this presentation we will talk about different network topologies and Fieldbus solutions for different
More informationFisher 4200 Series Electronic Position Transmitters
Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic
More informationLevel Lance Model 5100
Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection
More informationCertificate of Compliance
FF01 Certificate of Compliance Certificate: 1294176 Master Contract: 209996 Project: 1294176 Issued to: Seika Mikrosystemtechnik GmbH Ellharter StraBe 10 D-87435 Kempten GERMANY The products listed below
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationPROline promag 53 Division 1
XA 040D/06/en/05.01 50099923 FM+SGML 6.0 PROline promag 53 Division 1 Ex Ex documentation for the BA 053D and BA 054D operating instructions according to FACTORY MUTUAL standards documentation for the
More informationHT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions
HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models HT880 and HT885 are 2-wire temperature
More informationQUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES
QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES The Quartz is available in explosion/flame proof (QX), intrinsically safe and nonincendive (QN) and general purpose (QG) versions. The robust
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationFisher 646 Electro Pneumatic Transducer
Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationESSENTIAL INSTRUCTIONS Read this page before proceeding!
Instruction Sheet LIQ_MAN_ABR_/Rev.G January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical,
More informationInstruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams
Instruction MI 019-175 October 2000 I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams MI 019-175 October 2000 Intrinsically Safe Connection Diagrams If your Model 83.-D/-T
More informationLIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015
instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 FOUNDATION fieldbus Two-Wire ph/orp Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your Rosemount Analytical
More informationMCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol
SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable
More informationINTRINSIC SAFETY BASIC PRINCIPLES
INTRINSIC SAFETY BASIC PRINCIPLES IGNITION TRIANGLE Ignition Energy In many industrial processes, the presence of flammable materials (gases, vapours, liquids, dusts, fibres and flyings) requires the adoption
More informationProduct manual wire programmable RTD transmitter
Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationQN5, QXB, QNB, QX7, QN7, QXC, QNC
QUARTZ 4-0 ma Position Transmitter or Potentiometer w/switches (QX, QN, QXB, QNB, QX, QN, QX, QN ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to
More informationSafety Instructions Proline Promass 100
XA00160D/06/EN/03.14 71261250 Products Solutions Services Safety Instructions Proline Promass 100 Modbus RS485 Cl.I Div.1, Zone 1 for IS (Ex i Intrinsically safe version) C US Document: XA00160D Safety
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationINTRINSICALLY SAFE DUPLEXER
INTRINSICALLY SAFE DUPLEXER MADE IN THE U.S.A. DESCRIPTION The Intrinsically Safe Duplexer, ISD, is a low cost SCADA ready intrinsically safe pump controller designed to perform level control for duplex
More informationMid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.
More informationSafety Instructions Proline Promag 500
XA01524D/06/EN/01.16 71327947 Products Solutions Services Safety Instructions Proline Promag 500 Cl.I, II, III Div.1 for XP (Ex d Flameproofed version) C US Document: XA01524D Safety instructions for electrical
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationFisher 646 Electro-Pneumatic Transducers
Product Bulletin D101374X012 646 Transducers Fisher 646 Electro-Pneumatic Transducers Fisher 646 electro-pneumatic transducers, shown in figure 1, use a patented converter module that converts a 4 to 20
More informationThe T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.
GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional
More informationD1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater
D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationFLEX Ex Power Supplies
Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must
More informationThe T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.
GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional
More informationMid-West. Instrument. Model 142 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL
Mid-West Instrument Model 142 Electrical Installation and Operating Instructions BULLETIN NO. ELEC. IM142/14A Supersedes ELEC. IM142/10A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically
More informationModel LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR
DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 203-368-6751 FAX 203-368-3747 http://www.devarinc.com e-mail: info@devarinc.com Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR R Manual No. 990649
More informationFLEX Ex V ac In/Quad-Ex dc Out Power Supply
Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationORIGINAL SIZE SYSTEM CONTROL DWG. FILE. ROSEMOUNT 2410 OrCADl. o o
CH. ORDER CH. ORDER N CH. ORDER N CH. ORDER N FIELDBUS INTRINSICALLY SAFE CONCEPT (FISCO) APPROVAL FISCO allws f intrinsically safe apparatus t assciated apparatus nt specially examined in such cmbinatin.
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationAll TXI7850 products are ROHS compliant.
Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationUser s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).
User s Manual Model DY Vortex Flowmeter (Integral Type, Remote Type) Model DYA Vortex Flow Converter (Remote Type) FOUNDATION Fieldbus Communication Type Manual Change No.14-013V-E Please use the attached
More informationINSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D
D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System
More informationAnnex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter
Description RotaMass 3 Series Coriolis Mass Flow Meter; - Integral Transmitter, Model RCCx; - Remote Converter, Model RCCF31; - Remote Converter, Model RCCR31; - Remote Detector Model RCCS3xxxx The Coriolis
More informationCOMMUNICATION NETWORKS
Zone Applications (PROFIBU PA) MB eptember 2008 COMMUNICATION NETWORK FOR ZONE APPLICATION (PROFIBU PA) Michael Bean - 8 eptember 2008 INTRODUCTION: In recent years it has become increasingly popular to
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationPositioner with HART Communication Type 3780
Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels
More informationGTS High Frequency Pulser. Technical Bulletin
GTS High Frequency Pulser Technical Bulletin 02 Elster American Meter High Frequency Pulser System control and data acquisition in gas distribution networks begins with process sensors: sensors to detect
More informationOperating Principles
Features Explosion-proof NEMA 4X, IP65, Type 4 enclosure for outdoor and indoor installations. Optional tapped exhaust port vents exhaust gas. Canadian Registration Numbers (CRN) certification for all
More informationModel T7800 Series Electro-Pneumatic I/P, E/P Transducer
Model T7800 Series Electro-Pneumatic I/P, E/P Transducer General Information The T7800 Series Transducers provide maximum versatility for precision applications. Field Reversible Feature provides output
More informationLIQ_MAN_ABR_5081T-HT/Rev. L January 2015
instruction Sheet 5081T-HT LIQ_MAN_ABR_5081T-HT/Rev. L January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase
More informationNew Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous. Ron Dechene Auburn Systems, LLC Danvers MA 01923
New Report Indicates AC Inductance/Electrodynamic Dust Detectors May Be Hazardous Ron Dechene Auburn Systems, LLC Danvers MA 01923 Summary An independent study has concluded that polymer jacketed, or coated,
More informationFM Control Drawing Class I Division 2 / Class I Zone 2. Compact version PROMAG 10
Hazardous Locations Class I Div. 2 Groups ABCD or Class I Zone 2 Groups IIC and Class II and III Division 1 Groups EFG W / P / E / H / D / L Notes: 1. Control room equipment shall not use or generate more
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationTitle: INTRINSIC SAFETY MADE EASY
Title: INTRINSIC SAFETY MADE EASY By: TH Kuan KL Automation Engineering Sdn. Bhd. ICA 2006 Date: 19.02.2006 Profile of Kuan Teik Hua Mr. Kuan is a Director for KL Automation Engineering Sdn Bhd. He has
More informationPaddle wheel flow controller for On/Off control
addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationCOMMUNICATION AND CONTROL
QURTZ QX/QN/QG SERIES VLVE OMMUNITION ND ONTROL EXPLOSIONPROOF, NONINENDIVE, I.S. & GENERL PURPOSE ON/OFF VLVE MONITOR limit switch QURTZ QX/QN/QG 7 QZ 22 EN 5/2018 METSO 7 QZ 22 EN Quartz Explosionproof
More informationYVP110 Advanced Valve Positioner
User s Manual YVP110 Advanced Valve Positioner 10th Edition i YVP110 Advanced Valve Positioner 10th Edition CONTENTS Introduction...viii Notes on the User s Manual... viii For Safe Use of Product... viii
More informationTHE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC)
THE PROBE, 5 METER, 2WIRE, LOOP POWERED SINGLE POINT LEVEL MEASUREMENT SYSTEM (ULTRASONIC) Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic, single-point level controller
More informationoxy.iq Panametrics Oxygen Transmitter Applications Features bhge.com Two-wire, loop-powered 4 to 20 ma transmitter An oxygen transmitter for use in:
oxy.iq Panametrics Oxygen Transmitter Applications An oxygen transmitter for use in: Glove box purge and leak detection Natural gas Semiconductor wafer machines Coating process machines Membrane air separators
More informationMicro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc
ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters
Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14
More informationWireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual
Wireless Interface RAD-ISM-900-SET-BD-BUS Two-way (point-to-point) Monitoring and Control with Expandable I/O Options User Manual ) ) ) ) ) ) ) ) ) ) ) ) Notice: These devices must be wired in accordance
More informationINSTRUCTION & SAFETY MANUAL
D1044S - D1044D INSTRUCTION & SAFETY MANUAL - Digital Relay Output Loop / Bus Powered DIN-Rail Models D1044S, D1044D D1044 - - Digital Relay Output ISM000-10 General Description: The single and dual channel
More informationTÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.
GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationCertificate of Compliance
Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed
More informationHumidity Sensor/Transmitter Assembly
Humidity Sensor/Transmitter Assembly Wall/Duct Space Outside Air (OSA) Overview Minco humidity and humidity/temperature transmitters are designed using an advanced microprocessor. Digital signal processing
More informationFisher LCP100 Local Control Panel
Instruction Manual Local Control Panel Fisher Local Control Panel Contents Introduction... Scope of Manual... Description... Specifications... Educational Services... Installation... 5 Hazardous Area Classifications
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:
More informationControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD
Product Information Package PIP-CW ISProx Jul., 007 ControlWave ISProx Board ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD For ControlWave EFM/GFC/GFC Correctors Remote Automation Solutions
More informationSafety Instructions Micropilot NMR81, NMR84
XA0436G-A/00/EN/0.6 733528 Products Solutions Services Safety Instructions NMR8, NMR84 CA: XP / I / / B,C,D / Tx Ta* IS / I / / A,B,C,D / Tx Ta* I / / Ex db IIC Tx Gb Ta* I / 0 / Ex ia IIC Tx Ga Ta* I
More informationUser's Manual Model SE14 Magnetic Flow Converter
User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the
More informationRosemount 5400 Series Radar Level Transmitter
Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights
More informationKotron Model 82 CE RF Level Transmitter
Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationAmerican Power Design, Inc.
, Inc. FEATURES 4 Customer Selects Output Voltage 4 Ultra Wide Input Ranges (936Vdc, 2060Vdc) 4 Efficiency 89% (typ.) 4 Independently Isolated Outputs 4 SixSided Shielded Case 4 Remote On/Off Control 4
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationProcessMaster, HygienicMaster FEX300, FEX500
SM/FEX300/FEX500/FM/CSA-EN ProcessMaster, HygienicMaster FEX300, FEX500 FM / cfm Div. 1, Div. 2 Safety information for electrical equipment for potentially explosive areas in accordance with Factory Mutual
More information