1 QUARTZ with -0 ma Position Transmitter or Potentiometer (QXO, QNO, QXBO, QNBO, QXO, QNO, QXO, QNO ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to actuator using fasteners and lockwashers provided.. Loosen indicator cover set-screw. a. Rotate indicator cover to desired viewing angle and retighten set-screw. (Make sure indicator cover is pushed all the way into housing slot.). Rotate coupling spacer and indicator drum to desired position. (OPEN or LOSED appearing through indicator window). Remove spacer screw and fit torque coupling or Namur coupling onto coupling spacer. Separate spacer and indicator drum and rotate spacer to align coupling with actuator shaft. Fit coupling spacer over indicator drum drive hub. a. Secure torque coupling assembly or Namur coupling with screw of proper length. (Additional coupling spacers and longer screw may be required on some mountings.) AUTION: TO PREVENT IGNITION OF ATMOSPHERES, REPLAE OVER BEFORE ENERGIZING THE ELETRI- AL IRUITS.. Slide Thru-Bolts with washers into housing and fit retaining quad-rings over bolts to retain them. a. Top of actuator shaft should be within /" (.mm) from coupling screw head or Namur coupler. b. Torque coupler or Namur coupler must be fully engaged in slot and be centered on the shaft or block attached to the shaft.. Operate actuator to full open and full closed positions and check for proper alignment between switch and actuator. Eccentricity of shaft must be no greater than.0" (.mm) from centerline. The torque coupler or Namur coupler must be centered on the flats of the actuator shaft or block in both the full open and full closed position. Realign as necessary and final tighten Thru-Bolts.. "Fine-tune" visual indicator cover repeating # and lightly tighten set screw. KEEP OVER TIGHTLY LOSED WHEN IN OPERATION. NOTE: FOR SIL APPLIATIONS REFERENE THE QUARTZ VALVE POSITION INDIATOR SAFETY MANUAL AVAIL- ABLE AT: StoneL US Hwy Fergus Falls, MN USA Approval Agency led Document. No hanges Authorized Without Prior Agency Approval 0 StoneL Telephone:.. Toll Free: 00.. Fax:.. sales@stonel.com Website:

2 Specifications: (QXO, QNO, QXO, QNO) Output: -0 ma Voltage Range: 0 to 0 VD Recommended Voltage: VD, 0 ma Minimum Max Load: 00 VD (See Load urve) Span: Adjustable from to 0 QUARTZ with Position Transmitter Pub # 00rev Page Max Linearity Error: Standard Potentiometer + 0. High Perf. Potentiometer + 0. Temperature Range: -0 to 0 NOTE: For SIL applications reference the Quartz Valve Position Indicator Safety Manual available at Loop Resistance - + position transmitter Electrical Schematic to 00% ammeter or analog computer input + - voltage supply VD Power Supply Voltage Position Transmitter alibration. onnect the plug as shown for either clockwise or counter clockwise to open operation (as viewed from top).. Operate actuator to desired "zero" position. With power disconnected, connect an ohm meter across the terminals located on top of the potentiometer. For counter clockwise rotation, connect to the terminals with the black lead and white lead. For clockwise rotation, connect the ohm meter to the terminals with the red lead and and white lead.. Loosen bottom set screw and rotate coupling until the ohm meter reads between ohms. Retighten set screw, verify the ohm meter still reads between ohms.. Disconnect the ohm meter and connect D power to the positive (+) and negative (-) terminals (see electrical schematic).. Adjust the screw on the zero trimpot for a ma output. Operate actuator to the desired "00%" position.. Adjust the screw on the span trimpot for a 0mA output. Zero and Span adjustments are non interactive. Wiring Diagram.. Red White Black Trans. Spares + -. Trans + Trans - Spare Spare Transmitter.. NOTE Plug Must Be at One End of onnector or the Other. Spare Spare Z E R O S P A N lockwise to Open Operation Pins Visible Pins Visible Z E R O S P A N ounter lockwise to Open Operation StoneL Phone: () - Toll-free: (00) - Website:

3 Publ #00rev Page TOP NO/N BOTTOM NO/N -0mA TRANSMITTER Red (+) Black (-) lass I, II, III; Division Groups A,B,,D,E,F,G FM INSTALLATION NOTES: Entity Parameters: Vmax = 0 Vdc Imax = 00 ma i = nf Li = 0.0 mh Pi =.0 W. Voc or Vt < Vmax, Isc or It < Imax, a > i + cable, La > Li + Lcable.. Dust-tight conduit seal must be used when installed in lass II and lass III environments.. equipment connected to barrier must not use or generate more than 0 Vrms or Vdc.. Installation should be in accordance with ANSI/ISA RPA. "Installation of Systems for Hazardous (lassified) Locations" and the National Electrical ode (ANSI/NFPA 0).. The configuration of associated apparatus for each sensor wiring pair must be FMR Approved.. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground.. Switches and/or transmitter are optional based on model number. (if more than switches, follow instructions above for each switch.). onduit ing - Upon installation verify electrical continuity between conduit and ground terminal. 0. Substitution of components may impair hazardous location safety. Notes:. The QN and QN series devices are approved under the Entity oncept as for lass I, Division, Groups A, B,, & D, lass II, Division, Groups E,F, & G, and lass III, Division Hazardous (lassified) locations. Under the Entity oncept the parameters for the QN and QN devices are Vmax=0V, Imax=00mA, i=nf, Li=0.0mH. In order to have an approved loop the associated apparatus (barriers) must be FMR approved under the Entity oncept with the following parameters: Voc=0V, Isc=00mA. The control drawing for the associated apparatus will specify the allowed connected inductance and capacitance.. Installation of the solenoid and its associated barrier must be in accordance with the respective control drawings supplied by the respective manufacturers. This equipment must be approved by Factory Mutual Research orporation as for lass I, Division Hazardous (lassified) locations. WARNING:. When used in intrinsic safety applications, the aluminum enclosure shall be installed in such a manner as to prevent the. To prevent the risk of electrostatic sparking, the equipment enclosure shall be cleaned only with a damp cloth. StoneL Phone: () - Toll-free: (00) - Website:

4 Ex ia II T/T Publ #00rev Page TOP NO/N BOTTOM NO/N -0mA TRANSMITTER Red (+) Black (-) 0 INSTALLATION NOTES (Ex ia II T/T): Entity Parameters: Ui = 0 Vdc; Ii = 00 ma; i = nf; Li = 0. mh; Pi =.0 W 0. Voc or Vt < Ui, Isc or It < Ii, a > i + cable, La > Li + Lcable.. Dust-tight conduit seal must be used when installed in Zone 0, Zone, and Zone environments or where Ingress Protection of IP is required.. equipment connected to barrier must not use or generate more than 0 Vrms or Vdc.. Installation should be in accordance with appropriate local code or practice.. The configuration of associated apparatus for each sensor wiring pair or solenoid wiring pair must be approved.. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor or solenoid coil wiring must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground.. onduit ing - Upon installation verify electrical continuity between conduit and ground terminal.. Resistance between Intrinsic Safe and earth ground must be less than one ohm. 0. Substitution of components may impair hazardous location safety. Special onditions for Safe Use:. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions which might cause a build up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should be done only with a damp cloth.. When installed within a Zone 0 location, the aluminum alloy enclosure shall be installed in such a manner as to prevent the StoneL Phone: () - Toll-free: (00) - Website:

5 Specifications Standard Potentiometer (B): Output: 0-0K Ohms +/- % Linearity: +/- 0.% Power Rating: 0. 0 ycle Life: Two million shaft rotations Vibration tolerance: Acceptable Temp Range: -0 to 0 QUARTZ with Potentiometer High Performance Potentiometer (): Output: 0-0K Ohms +/- 0.% Linearity: +/- 0.0% Power Rating: 0. 0 ycle Life: 0 million shaft rotations Vibration tolerance: Outstanding Temp Range: -0 to 0 Pub # 00rev Page NOTE: FOR SIL APPLIATIONS REFERENE THE QUARTZ VALVE POSITION INDIATOR SAFETY MANUAL AVAIL- ABLE AT: Wiring Diagram Electrical Schematic POT SPARES Potentiometer alibration. Operate actuator to desired "zero" position. onnect an ohm meter across the terminals located on top, or side, of the potentiometer. For counter clockwise rotation (Ohm value to increase), connect to the terminals with the Red lead (#) and Red/Black lead (#). For clockwise rotation, connect the ohm meter to the terminals with the Red lead (#) and Red/Blue lead (#).. Loosen bottom set screw and rotate coupling until the ohm meter reads < 0 Ohms. Retighten set screw, verify the ohm meter still reads <0 Ohms.. Operate actuator to the desired "00%" position (assuming 0 degress rotation) and verify ohmmeter reads.k Ohms +/- 0%.. Remove all test equipment and place unit in service.. W Red/Black wire. # Red w/black # Red # Red w/blue Red wire POT TOP SW BTM SW SPARES NO N N NO Red/Blue wire StoneL Phone: () - Toll-free: (00) - Website:

6 Publ #00rev Page POTENTIOMETER Red/Black () Red () Red/Blue () lass I, II, III; Division Groups A,B,,D,E,F,G FM INSTALLATION NOTES: Entity Parameters: Vmax = Vdc Imax = ma i = 0.0 nf Li = 0.0 mh Pi = 0 mw. Voc or Vt < Vmax, Isc or It < Imax, a > i + cable, La > Li + Lcable.. Dust-tight conduit seal must be used when installed in lass II and lass III environments.. equipment connected to barrier must not use or generate more than 0 Vrms or Vdc.. Installation should be in accordance with ANSI/ISA RPA. "Installation of Systems for Hazardous (lassified) Locations" and the National Electrical ode (ANSI/NFPA 0).. The configuration of associated apparatus for each sensor wiring pair must be FMR Approved.. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground.. Switches and/or pontentiometer are optional based on model number. (if more than switches, follow instructions above for each switch.). onduit ing - Upon installation verify electrical continuity between conduit and ground terminal. 0. Substitution of components may impair hazardous location safety. Notes:. The QNB and QN series devices are approved under the Entity oncept as for lass I, Division, Groups A, B,, & D, lass II, Division, Groups E,F, & G, and lass III, Division Hazardous (lassified) locations. Under the Entity oncept the parameters for the QNB and QN devices are Vmax=0V, Imax=00mA, i=nf, Li=0.0mH. In order to have an approved loop the associated apparatus (barriers) must be FMR approved under the Entity oncept with the following parameters: Voc=0V, Isc=00mA. The control drawing for the associated apparatus will specify the allowed connected inductance and capacitance.. Installation of the solenoid and its associated barrier must be in accordance with the respective control drawings supplied by the respective manufacturers. This equipment must be approved by Factory Mutual Research orporation as for lass I, Division Hazardous (lassified) locations. WARNING:. When used in intrinsic safety applications, the limit switch shall be installed in such a manner as to prevent the. To prevent the risk of electrostatic sparking, the equipment enclosure shall be cleaned only with a damp cloth. StoneL Phone: () - Toll-free: (00) - Website:

7 Publ #00rev Page Ex ia II T/T Red/Black () POTENTIOMETER Red () Red/Blue () 0 INSTALLATION NOTES (Ex ia II T/T): Entity Parameters: Ui = Vdc; Ii = ma; i = 0.0 nf; Li = 0.0 mh; Pi = 0 mw 0. Voc or Vt < Ui, Isc or It < Ii, a > i + cable, La > Li + Lcable.. Dust-tight conduit seal must be used when installed in Zone 0, Zone, and Zone environments or where Ingress Protection of IP is required.. equipment connected to barrier must not use or generate more than 0 Vrms or Vdc.. Installation should be in accordance with appropriate local code or practice.. The configuration of associated apparatus for each sensor wiring pair or solenoid wiring pair must be approved.. Associated apparatus manufacturer's installation drawing must be followed when installing this equipment.. To maintain intrinsic safety, wiring associated with each sensor or solenoid coil wiring must be run in separate cables or separate shields connected to intrinsically safe (associated apparatus) ground.. onduit ing - Upon installation verify electrical continuity between conduit and ground terminal.. Resistance between Intrinsic Safe and earth ground must be less than one ohm. 0. Substitution of components may impair hazardous location safety. Special onditions for Safe Use:. Parts of the enclosure are non-conducting and may generate an ignition-capable level of electrostatic charge under certain extreme conditions. The user should ensure that the equipment is not installed in a location where it may be subjected to external conditions which might cause a build up of electrostatic charge on non-conducting surfaces. Additionally, cleaning of the equipment should be done only with a damp cloth.. When installed within a Zone 0 location, the aluminum alloy enclosure shall be installed in such a manner as to prevent the StoneL Phone: () - Toll-free: (00) - Website:

QN5, QXB, QNB, QX7, QN7, QXC, QNC

QN5, QXB, QNB, QX7, QN7, QXC, QNC QUARTZ 4-0 ma Position Transmitter or Potentiometer w/switches (QX, QN, QXB, QNB, QX, QN, QX, QN ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to

More information

EN Series Installation Manual

EN Series Installation Manual Pub # 007revG EN Series Installation Manual Approval Agency Controlled Document. No Changes Authorized Without Prior Agency Approval StoneL 7 US Highway 9 Fergus Falls, MN 7 USA Telephone: (8) 79-77 Fax:

More information

JM Enclosure Dimensions (in mm)

JM Enclosure Dimensions (in mm) ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions AH71, AH72, and AH73 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models AH71, AH72, and AH73 are

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT

More information

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions

HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions HT880 and HT885 FM Approved Humidity Transmitter Assemblies Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Models HT880 and HT885 are 2-wire temperature

More information

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class: Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Loop Powered Indicator

Loop Powered Indicator Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

Product manual wire programmable RTD transmitter

Product manual wire programmable RTD transmitter Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001

More information

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse

More information

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams Instruction MI 019-175 October 2000 I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams MI 019-175 October 2000 Intrinsically Safe Connection Diagrams If your Model 83.-D/-T

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

OPTITEMP TT 10 C/R Technical Datasheet

OPTITEMP TT 10 C/R Technical Datasheet OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The

More information

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

ESSENTIAL INSTRUCTIONS Read this page before proceeding! Instruction Sheet LIQ_MAN_ABR_/Rev.G January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical,

More information

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL CAP ANALOG 410 INSTALLATION & OPERATION MANUAL An L&J Technologies Co. 5911 Butterfield Road Hillside, IL 60162 Phone: 708-236-6000 Fax: 708-236-6006 1 was started in 1976 to offer new and innovative electronic

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

Fisher 4200 Series Electronic Position Transmitters

Fisher 4200 Series Electronic Position Transmitters Product Bulletin D200357012 4200 Series Transmitter Fisher 4200 Series Electronic Position Transmitters Fisher 4200 Series electronic position transmitters (figure 1 and 2) combine field-proven electronic

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

Certificate of Compliance

Certificate of Compliance FF01 Certificate of Compliance Certificate: 1294176 Master Contract: 209996 Project: 1294176 Issued to: Seika Mikrosystemtechnik GmbH Ellharter StraBe 10 D-87435 Kempten GERMANY The products listed below

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

FLEX Ex Power Supplies

FLEX Ex Power Supplies Installation Instructions FLEX Ex Power Supplies (Cat. Nos. 1797-PS2N, -PS2E) About the Power Supplies The power supply is an essential component in the operation of an intrinsically safe system. It must

More information

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th). User s Manual Model DY Vortex Flowmeter (Integral Type, Remote Type) Model DYA Vortex Flow Converter (Remote Type) FOUNDATION Fieldbus Communication Type Manual Change No.14-013V-E Please use the attached

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

R88000 T (including ATEX)

R88000 T (including ATEX) INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:

More information

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

FLEX Ex V ac In/Quad-Ex dc Out Power Supply Installation Instructions FLEX Ex 85 250V ac In/Quad-Ex dc Out Power Supply Catalog Number 1797-PS1N Topic Important User Information 2 About the Power Supplies 3 Understand System Planning 4 Electrostatic

More information

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR

Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR DEVAR Inc. 706 Bostwick Avenue, Bridgeport, CT 06605 203-368-6751 FAX 203-368-3747 http://www.devarinc.com e-mail: info@devarinc.com Model LD-LPIX EXPLOSION-PROOF LOOP POWERED INDICATOR R Manual No. 990649

More information

Industrial Pressure Transducers

Industrial Pressure Transducers Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are

More information

670K9 SORtrax Level Transmitter

670K9 SORtrax Level Transmitter SORtrax is a 4-20 ma continuous level transmitter. It produces a 4-20mA current superimposed on the 12-55 VDC loop supply lines. The 4-20mA current is proportional to the level sensed by the instrument.

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT

Instruction Manual T-800 Series Current Transmitter. Model T-800L Model T-800LT Model T-800TT Instruction Manual T-800 Series Current Transmitter Model T-800L Model T-800LT Model T-800TT M323 Rev G1 September 10, 2009 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Telephone: 978-486

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

User's Manual Model SE14 Magnetic Flow Converter

User's Manual Model SE14 Magnetic Flow Converter User's Manual Model SE14 Magnetic Flow Converter Manual Change No. 09-001-6E Please use attached sheets for the pages listed below in (7th). Page Page 10-2 EMC Conformity Standards Contents Changed the

More information

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital) Instruction Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

YTA610 and YTA710 Temperature Transmitter (Hardware)

YTA610 and YTA710 Temperature Transmitter (Hardware) User s Manual YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition 1 YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...1-1

More information

Rosemount 5408 and 5408:SIS Level Transmitters

Rosemount 5408 and 5408:SIS Level Transmitters Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines

More information

Page Type Resolution (mm) min. max. Output

Page Type Resolution (mm) min. max. Output Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

Installation guide 854 XTG Level Gauge

Installation guide 854 XTG Level Gauge Installation guide 854 XTG Level Gauge July 2008 Part no. 4416.276 Rev. 5 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

LIQ_MAN_ABR_5081T-HT/Rev. L January 2015

LIQ_MAN_ABR_5081T-HT/Rev. L January 2015 instruction Sheet 5081T-HT LIQ_MAN_ABR_5081T-HT/Rev. L January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase

More information

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

Transducer transmitter BILT 4 II 2(1) G. Technical Manual GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical

More information

Rosemount 5400 Series Radar Level Transmitter

Rosemount 5400 Series Radar Level Transmitter Radar Level Transmitter Start Step 1: Mount the Transmitter Step 2: Connect the Wiring Step 3: Configure Confirm Configuration End HART 00825-0100-4026I www.rosemount.com 2007 Rosemount Inc. All rights

More information

BFS / BFSM SERIES Installation & Maintenance Manual

BFS / BFSM SERIES Installation & Maintenance Manual Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both

More information

Rosemount 753R Remote Web Based Monitoring Indicator

Rosemount 753R Remote Web Based Monitoring Indicator Rosemount 753R Remote Web Based Monitoring Indicator Product Discontinued February 2010 Start Overview Rosemount 753R with Integral 3051S Pressure Transmitter Rosemount 753R with Remote Mounted HART Transmitter

More information

Installation guide 971 SmartRadar LTi

Installation guide 971 SmartRadar LTi Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl

More information

Rotary Position Technology

Rotary Position Technology Magnetic Rings LM-2 / RMT-2 High rotational speed IP High IP Shock/vibration resistant Reverse polarity protection Robust Increased ability to withstand vibrations and rough installation: Eliminates machine

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

INTRINSICALLY SAFE DUPLEXER

INTRINSICALLY SAFE DUPLEXER INTRINSICALLY SAFE DUPLEXER MADE IN THE U.S.A. DESCRIPTION The Intrinsically Safe Duplexer, ISD, is a low cost SCADA ready intrinsically safe pump controller designed to perform level control for duplex

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

Sized for Print. Primary timing chain - from 08/ L, without supercharger. Special Service tools. Camshaft Setting Tool

Sized for Print. Primary timing chain - from 08/ L, without supercharger. Special Service tools. Camshaft Setting Tool Primary timing chain - from 08/1998 4.0L, without supercharger Special Service tools Camshaft Setting Tool 303-530 Timing chain tensioning tool 303-532 Wedges, primary chain 303-533 http://alldatapro.com/alldata/pro~v376737902~c36065~r0~od~n/0/80851247/83501684/84900382/86331920/34853741/100411974/34853743/56492475/1445

More information

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL Mid-West Instrument BULLETIN NO. ELEC-IM140/11A Replaces ELEC-IM140-141/09A ELECTRICAL Gauges with switches have one or two SPST or SPDT hermetically sealed adjustable set point reed switch assemblies.

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:

More information

MODEL LP35 LP SERIES LOW PROFILE INTRINSIC SAFETY INCREMENTAL ENCODER

MODEL LP35 LP SERIES LOW PROFILE INTRINSIC SAFETY INCREMENTAL ENCODER MODEL LP35 LP SERIES LOW PROFILE INTRINSIC SAFETY INCREMENTAL ENCODER Features Certified for use in Class I & II, Div. 1 and Zone 0 and 1 hazardous areas Low profile package saves space Excellent resistance

More information

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4

Nemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4 I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)

More information

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005

White Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005 White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49

More information

COMMUNICATION AND CONTROL

COMMUNICATION AND CONTROL QURTZ QX/QN/QG SERIES VLVE OMMUNITION ND ONTROL EXPLOSIONPROOF, NONINENDIVE, I.S. & GENERL PURPOSE ON/OFF VLVE MONITOR limit switch QURTZ QX/QN/QG 7 QZ 22 EN 5/2018 METSO 7 QZ 22 EN Quartz Explosionproof

More information

F2xx & F2xx-XE megablock range

F2xx & F2xx-XE megablock range Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer

Model T7800 Series Electro-Pneumatic I/P, E/P Transducer Model T7800 Series Electro-Pneumatic I/P, E/P Transducer General Information The T7800 Series Transducers provide maximum versatility for precision applications. Field Reversible Feature provides output

More information

Optical Kit Encoder Page 1 of 11. Description. Mechanical Drawing. Features

Optical Kit Encoder Page 1 of 11. Description. Mechanical Drawing. Features Description Page 1 of 11 The E3 is a high resolution rotary encoder with a molded polycarbonate enclosure, which utilizes either a 5-pin locking or standard connector. This optical incremental encoder

More information

F2xx & F2xx-XE Megablock Series

F2xx & F2xx-XE Megablock Series technical datasheet technical datasheet Fxx & Fxx-XE Megablock Series passive hubs for Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They

More information

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters The Vaisala HUMIAP Humidity and Temperature Transmitter HMT361 wall mount transmitter, shown with six probe options, is designed specifically for hazardous and explosive environments. 10 Gill Street, Woburn,

More information

25000 Series Lo-T TM Butterfly Control Valve Instructions

25000 Series Lo-T TM Butterfly Control Valve Instructions November 2001 25000 Series Lo-T TM Butterfly Control Valve Instructions Instruction No. 25.1:IM PRELIMINARY STEPS Before installation, note the flow direction arrow on the valve body. The flow should enter

More information

LIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015

LIQ_MAN_ABR_5081P-FF-FI/Rev. D January 2015 instruction Sheet 1a-01p-ff/fi LIQ_MAN_ABR_01P-FF-FI/Rev. D January 201 FOUNDATION fieldbus Two-Wire ph/orp Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your Rosemount Analytical

More information

SAFETY INSTRUCTIONS. Wear protective clothing, including safety glasses and steel toe boots.

SAFETY INSTRUCTIONS. Wear protective clothing, including safety glasses and steel toe boots. SAFETY INSTRUCTIONS Wear protective clothing, including safety glasses and steel toe boots. DO NOT allow loose clothing or long hair near machine operations. Keep work site and machine clean. Use brush

More information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3

More information

INTRINSIC SAFETY BASIC PRINCIPLES

INTRINSIC SAFETY BASIC PRINCIPLES INTRINSIC SAFETY BASIC PRINCIPLES IGNITION TRIANGLE Ignition Energy In many industrial processes, the presence of flammable materials (gases, vapours, liquids, dusts, fibres and flyings) requires the adoption

More information

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD Product Information Package PIP-CW ISProx Jul., 007 ControlWave ISProx Board ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD For ControlWave EFM/GFC/GFC Correctors Remote Automation Solutions

More information

Armstrong Intelligent Monitoring Installation and Operation Manual

Armstrong Intelligent Monitoring Installation and Operation Manual Armstrong Intelligent Monitoring Installation and Operation Manual Models: AD5000, ST5700, TD5100 IOM-256-B Please read and save these instructions Installation and Set Up Overview Warning: Lithium Batteries

More information

QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES

QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES QUARTZ LIMIT SWITCH FOR HAZARDOUS AREAS AND GENERAL PURPOSES The Quartz is available in explosion/flame proof (QX), intrinsically safe and nonincendive (QN) and general purpose (QG) versions. The robust

More information

Product Manual wire HART transmitter

Product Manual wire HART transmitter Product Manual 6335 2wire HART transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 6335V111UK From serial no.: 150951186 6 Product

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

RPE Parallel Gripper- Electric Gripper Series

RPE Parallel Gripper- Electric Gripper Series 1.14 RPE Parallel Gripper- Electric Gripper Series Failsafe Operation: Spring closed feature allows for full grip force during power off conditions. Electrically Actuated: Requires simple 24VDC pulsed

More information

Fisher LCP100 Local Control Panel

Fisher LCP100 Local Control Panel Instruction Manual Local Control Panel Fisher Local Control Panel Contents Introduction... Scope of Manual... Description... Specifications... Educational Services... Installation... 5 Hazardous Area Classifications

More information

Quick Start Guide , Rev CA April Rosemount 4088A MultiVariable Transmitter. with Modbus Output Protocol

Quick Start Guide , Rev CA April Rosemount 4088A MultiVariable Transmitter. with Modbus Output Protocol 00825-0100-4088, Rev CA Rosemount 4088A MultiVariable Transmitter with Modbus Output Protocol Safety messages NOTICE This guide provides basic guidelines for the Rosemount 4088 MultiVariable Transmitter.

More information

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer

More information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves

Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves Mounting Instructions For 3-Piece Namur Style Mounting Bracket To 2-Way 60 Series Valves NOTE: These instructions apply only to 60 series ball valves with bodies containing external mounting nibs. External

More information