1 CAP ANALOG 410 INSTALLATION & OPERATION MANUAL An L&J Technologies Co Butterfield Road Hillside, IL Phone: Fax:
2 was started in 1976 to offer new and innovative electronic designs in tank gauging. L&J s new products always used the latest electronics and therefore the company quickly grew. Ten years later L&J bought GPE. Along with GPE, L&J bought, a GPE affiliate that manufactures fittings and valves for the same type of tanks that used the gauging equipment. A short time later, all 3 companies were reorganized under one corporate entity called. In 1994, a brand new, state-of-the-art manufacturing facility was built to bring all of the L&J Technologies manufacturing efforts under one roof. In 1996, L&J bought, a manufacturer of liquid level controls and Hi/Low level switches for the boiler, process, and liquid storage industries. On February 28, 2000, L&J purchased Durlam Associates, (now Durlam Inc.). is located in Houston, Texas and is the leading manufacturer of fiberglass reinforced plastic (FRP) Derakane 470 conservation vents and fittings. On March 31, 2000, L&J purchased Delavan Process Instrumentation in Naugatuck, CT. is a well-established name in ultrasonic, capacitance and microwave point level and continuous level measurement for liquids and solids. Delavan was relocated to L&J Technologies corporate headquarters in Hillside, Illinois. Today, the L&J family of companies is the world s largest manufacturer specializing in the monitoring, management, and control of bulk liquids. L&J provides quality products for the Petroleum, Petrochemical, Chemical, Food, Pharmaceutical, Pipeline, Steel, Water Treatment and Biogas ( ) Industries. Visit L&J Technologies on the internet at 2
3 TABLE OF CONTENTS 1.0 Introduction Description Principle of Operation Specifications Installation Unpacking Mechanical Installation Non-Metallic Tank Electrical Installation Operation General Controls for Analog Output Controls for Relay Adjustment Indicators for Analog or Relay Adjustment Procedure Analog Preparation for Relay Adjustment Relay Adjustment Procedure -- Single Relay Relay #2 Adjustment Procedure Maintenance & Service Product Warranty
4 1.0 INTRODUCTION 1.1 Description The CAP-ANALOG/410 system consists of an electronic transmitter mounted in a Cast Aluminum Explosion Proof Housing. This housing normally is integrally mounted on the rear of the sensor probe. Probes are manufactured in a variety of insulating materials and metals. The active length of the probe will vary subject to the specific application of that system. The probe usually is mounted in a vertical position. Normally the probe is threaded into the process with a ¾ or 1" NPT connection. 1.2 Principle of Operation The CAP-ANALOG/410 along with its probe sensor operates as a capacitance sensitive system that converts changes in level to changes in capacitance. After calibration any change in level is recognized and converted to an analog output signal (4-20 ma or 0-10 VDC). The CAP-ANALOG.410 is supplied with two 20 turn, ZERO and SPAN adjust potentiometers. These controls are independent and non-interacting. In addition, two DIP Switches are provided to extend the range of the ZERO and SPAN potentiometers. 1.3 Specifications Supply Voltage: Nominal Absolute Limits 115 VAC VAC or 230 VAC VAC or VDC Frequency, AC Power 50-60Hz 45 Hz Min. Less than 3volts amps Output 4-20mA.300 Ohms D.C. Max VDC Housing Temperature Integral Explosion Proof & Weather Tight -40 to +160ºF (-40ºC to 71ºC) Span Low Range High Range Min Max Min Max Standard Range 50pfd 1000pfd 800pfd 10,000pfd High Gain Range 10pfd 200pfd - - Zero 10pfd 500pfd 10pfd 2000pfd Stability -/+.5 pf/30of (At minimum sensitivity) 2.0 INSTALLATION 2.1 Unpacking Normally the transmitter and the sensing probe are packed in separated cartons. Remove the contents of the shipping carton and check each item against the packing list before destroying any packing material. 2.2 Mechanical Installation Depending on the size and type of probe selected for use with this device, it may be preferable to mount the transmitter before installing the probe in the process vessel Unscrew and remove the Dome Cover Loosen the two captive flat head screws that secure the mounting bracket to the enclosure Remove the control unit from the enclosure Apply anti-seize type pipe sealant to the upper thread of the probe Thread the probe into the enclosure by hand To AVOID damage, screw a two-foot length of 1" threaded pipe to the side hub of the enclosure to grip while making up this connection. IMPORTANT: FOR HAZARDOUS AREA SERVICE, THE THREAD ENGAGEMENT OF THE PROBE MUST BE A MINIMUM OF FIVE (5) FULL THREADS. CONFIRM THE ENGAGEMENT IS ADEQUATE Insert the RED Banana Plug from the transmitter into the FEMALE Connection on the top of the probe Replace the transmitter in the enclosure and tighten the two (2) captive screws. 2.3 Non-Metallic Tanks When a non-metallic tank is used, a ground return should be installed to provide greater stability. This may be a metal rod installed in the tank or a ground strap fastened to the exterior of the tank. This ground should be fastened to the same earth ground as the instrument. 4
5 2.4 Electrical Installation Wire unit to power and control conduits in accordance with applicable electrical codes and power supply voltages Terminal Designations 1) Chassis Ground 2) Line Neutral For 115 VAC, connect power to terminals 2 & 3. 3) Line 115 VAC For 230 VAC, connect power to terminal 2 & 4. 4) Line 230 VAC (power off) 5) Spare 6) Low Voltage Input (-) Negative VDC 7) Low Voltage Input (+) Positive VDC 8) Signal Ground 9) 4-20 ma DC (-) 10) 0-10 V Out 11) 4-20 ma DC (+) 12) +12 V Out TERMINAL DESIGNATIONS/CALIBRATION ADJUSTMENTS GND. NEUT. 115 VAC 230 VAC SPARE LOW VOLT INPUT SIGNAL GROUND 4-20 IN 0-10 OUT OUT +12V OUT WARNING IF SYSTEM IS LOCATED IN HAZARDOUS AREA, BE SURE AREA IS "SAFE" BEFORE REMOVING COVER WITH UNIT ENERGIZED. INDICATOR CIRUIT ONLY. POWER MUST BE SUPPLIED TO AMPLIFIER AS SHOWN IN ITEM 2.4 TERMINAL CONNECTIONS OUTPUT SIGNALS DELAVANS BOARD Connections for 4-20 ma Grounded Out put. When the current loop can be grounded and the power for the 4-20mA signal is supplied by the CAP-ANALOG/ 410 connect as shown below: SIGNAL GROUND IN (-) V OUT OUT (+) V OUT mA DC JUMPER When the current loop is above ground and power is supplied by others the 4-20 ma signal should be connected as shown below. Total loop resistance should not be greater than 600 ohms. SIGNAL GROUND IN (-) V OUT OUT (+) V OUT TO 24 VDC 4-20 ma DC For 0 to 10 VDC output connect as shown below: NOTE: THAT EIGHT IS GROUNDED CUSTOMERS CONNECTIONS ZERO POT OPEN 1 2 SPAN RANGE ZERO RANGE SIGNAL GROUND IN VDC + SPAN POT 0-10 V OUT 10 ASSEMBLY NO SCHEMATIC NO INST. MANUAL NO SERIAL NO. INSPECTION 4-20 OUT V OUT OPERATIONS 3.1 General This section contains the calibration and operation information for the. DELAVAN 5
6 3.2 Controls The location of the adjustable controls are shown in Fig. #1. Their description and function are as follows: ZERO Adjustment This 20-turn potentiometer matches the ZERO point of the instrument to the desired process ZERO level SPAN Adjustment This 20-turn potentiometer matches the Full Scale SPAN (upper limit) to the desired upper limit of the process level RANGE Switches ZERO Range - Switch (2) This switch matches the instrument to the specific process Rotate SPAN and ZERO potentiometers fully counter-clockwise 20 turns Adjust SPAN Adjust potentiometer to near center position. Adjust ZERO potentiometer 4 full turns clockwise Connect a voltmeter capable of reading 10 volts DC to terminals 8 and 10. Negative to 8 and Positive to 10. NOTE: (If current meter is to be used, connect as shown on page (6) sketch 1 or 2 as applicable) Turn power ON If reading is greater than 5 volts (greater than 12mA), set ZERO Switch "S2" to its OPEN position. When reading is less than 5 volts (less than 12 ma) leave S2 in closed position. Adjust ZERO potentiometer until voltmeter reads about one volt, then CCW until it just reads zero volts (4mA). Be careful not to have a NEGATIVE reading. Range Dip Switch Position Low Closed High Open Span Range - Switch (1) Range Dip Switch Position Low Closed High Open Raise the level to the desired highest level Set SPAN Switch "SW #1" to its OPEN position. If reading is less than 5 volts (less than 12mA) return SW #1 to its CLOSED position. If reading is greater than 5 volts (more than 12mA), leave SW #1 in the OPEN position Adjust the SPAN Adjust potentiometer clockwise or counter-clockwise as required until voltage reading is 10 volts or current is 20 ma. 3.3 Indicators The CAP-ANALOG/410 without a voltmeter or current meter is a "BLIND" device. An analog or digital indicator may be connected as shown in section Adjustment Proceduress INFORMATION COMMON TO ALL CONITIONS -Zero Adjust and SPAN Adjust are 20 turn potentiometers with slip clutches at both ends Process material must be a minimum of 1" up from probe tip for proper zero setting Set SPAN Switch "SW #1" and ZERO Switch "SW #2" to CLOSED position. SYSTEM IS NOW CALIBRATED. 4.0 MAINTENANCE & SERVICE 4.1 One-Year Product Warranty DELAVAN PROCESS INSTRUMENTAION, control products will be replaced, put in good operating condition, or the purchase price refunded, at the option of DELAVAN, free of charges except transportation, if defective in their manufacture, labeling, packaging, or shipping, and if notice of said defect is received by DELAVAN within one year from the date of shipment. The cost of such replacement, repair or refund of purchase price shall be the exclusive remedy for any breach of any warranty, and DELAVAN shall not be liable to any person for consequential damages for injury or commercial loss resulting from any breach of any warranty. DELAVAN make no warranty of fitness for a particular purpose, and makes no other warranty, express or implied, including implied warranty arising from course of dealing or usage of trade. 6
7 7
8 REACHING NEW LEVELS IN PROCESS MEASUREMENT 5911 Butterfield Rd. Hillside, IL PH: (708) FAX: (708)
R.F. Capacitance Dual-Point Level Control INSTALLATION & OPERATION MANAUL
CAPTROL MODELS 510 R.F. Capacitance Dual-Point Level Control INSTALLATION & OPERATION MANAUL An L&J Technologies Co. 5911 Butterfield Road Hillside, IL 60162 Phone: 708-236-6000 Fax: 708-236-6006 1 was
More information670K9 SORtrax Level Transmitter
SORtrax is a 4-20 ma continuous level transmitter. It produces a 4-20mA current superimposed on the 12-55 VDC loop supply lines. The 4-20mA current is proportional to the level sensed by the instrument.
More informationSeries 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806
Series 500 Analog Transmitters by Data Industrial Data Industrial Owner s Manual Data Industrial 2/95 PN 72806 Table of Contents Introduction... 1 4-20 ma Loop Supply Requirements... 2 Installation...
More informationKotron Series 82 CE. Level. Transmitter. Installation and Operating Manual
Kotron Series 82 CE Installation and Operating Manual RF Level Transmitter Read this Manual Before Installing This manual provides information on the Kotron Series 82 CE RF Level Transmitter. It is important
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading edge microprocessor-based circuitry has nonvolatile memory. The display
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationKotron Sentinel Model 804 RF Level Transmitter
Kotron Sentinel Model 804 RF Level Transmitter D E S C R I P T I O N The Sentinel is a unique, powerful level transmitter. The leading-edge microprocessor-based circuitry has nonvolatile memory. The display
More informationKotron Model 82 CE RF Level Transmitter
Kotron Model 82 CE RF Level Transmitter DESCRIPTION The Kotron Model 82 RF Capacitance transmitter is one of the most cost effective level transmitters available today. Compact in size, it employs state-of-the-art
More informationFlow Detection MDS Integral or Remote Housing. Installation and Operating Instructions
Flow Detection MDS Integral or Remote Housing Solids - Chute and Conveyor 10.525 GHz Sender Receiver Installation and Operating Instructions Measurement Systems INTRODUCTION CONTENTS PROPRIETARY NOTICE
More informationDigital Lighting Systems, Inc.
PD408-AN0-277 ANALOG 0-0 V 0-0V analog control 4 Channel x 2250 W Dimmer & Switch Packs 220/240/277 Volts operation PD408-AN0-277 4 circuit Analog -0V 4 x 8 A. Dimmer pack Serial Number Digital Lighting
More informationBC145 SIGNAL ISOLATOR BOARD
BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download
More informationRicochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual
Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 500 Humbolt Street Los Alamitos, CA 9. If for
More informationOPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE
OPERATION & SERVICE MANUAL FOR FC 100 SERIES AC POWER SOURCE FC 110 AC POWER SOURCE VERSION 1.3, April 2001. copyright reserved. DWG No. FC00001 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 1 1.1 GENERAL...
More informationEchotel Model 910 Ultrasonic Level Switch
Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit
More informationKotron Sentinel Models 822, 832 and 842 RF Point Level Switches
Kotron Sentinel Models 8, 8 and 84 RF Point Level Switches D E S C R I P T I O N The Sentinel is a powerful multi-point level switch. The microprocessor-based circuitry has non-volatile memory, to protect
More informationRF-CAPACITANCE (Coat-Shield)Level Limit Switch
RF-CAPACITANCE (Coat-Shield)Level Limit Switch Levtester SLsC M series User Manual * Technical Specification * Safety information * Introduction * Measuring Principle * Measuring system * System description
More informationMODEL AT-10 ANALOG TRANSMITTER
MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca
More informationAn American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.
An American Control Electronics Brand PCM4 SERIES PCM4 USER MANUAL www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the PCM4 Series isolation card. This User Manual was created
More informationEchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure
EchoSonic II Ultrasonic Level Transmitter LU27 Series Quick Start NEMA 4X Enclosure QS300116 Rev C 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA 90720 USA Tel:
More informationAD-8100 & AD-8200 Servo Amplifiers
Instruction Manual IM-0607 AD-8100 & AD-8200 Servo Amplifiers Table of Contents General Information... 2 Basic Models... 3 Specifications... 3 Installation Wiring... 3 Setup & Calibration... 4-6 Troubleshooting
More informationRK Hydrogen Transmitter Operator s Manual
65-2451RK Hydrogen Transmitter Operator s Manual Part Number: 71-0133RK Revision: C Released: 5/17/11 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual before
More informationAMP-12 OPERATOR S MANUAL
AMP-12 OPERATOR S MANUAL Version 1.0 Copyright 2002 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationSawStop. Contractor Fence Assembly OWNER S MANUAL. Model CNS-SFA
Contractor Fence Assembly OWNER S MANUAL Model CNS-SFA Warranty warrants to the original retail purchaser of the Contractor Fence Assembly accompanying this manual that the fence assembly will be free
More informationKING-GAGE ES2. Installation and Operation Instructions Manual. Electronic Liquid Level Transmitter. ESR Serial No. Versions and Slimline Versions
Effective: November 2009 (replaces August 2009) KING-GAGE ES2 Electronic Liquid Level Transmitter Installation and Operation Instructions Manual ESR Serial No. Versions and Slimline Versions 2009 King
More informationSL300 Snow Depth Sensor USL300 SNOW DEPTH SENSOR. Revision User Manual
USL300 SNOW DEPTH SENSOR Revision 1.1.2 User Manual 1 Table of Contents 1. Introduction... 3 2. Operation... 3 2.1. Electrostatic Transducer... 4 2.2. SL300 Analog Board... 4 2.3. SL300 Digital Circuit
More informationRicochet Alphasonic Level Transmitter Model LA15 Owner s Manual
Warranty, Service & Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: Flowline Inc. 10500 Humbolt Street Los Alamitos, CA 90720. If
More information99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand
More informationAnalog Voltage Detector 0-40kV Operating Instructions VDA040CTM
Analog Voltage Detector 0-40kV Operating Instructions VDA040CTM CONTENTS Limitation of Warranty and Liability 2 Product Safety Information 3 Design and Function 4 Voltage Detection in the C Position 5-6
More informationRHS SERIES RH Set Point Controller/Probe
RHS SERIES RH Set Point Controller/Probe Publication Date: April 2005 Document Number: RHS-1-900-01 Rev B This owner s manual was as current as possible when this product was manufactured. However, products
More informationEffective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937
Effective: June, 2000 LevelPRO Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937 The information contained in this manual was accurate at the time of release. Specifications
More informationInstallation, Operation and Maintenance Manual
NIAGARA M513 Rev. B Model 1005 Pulse to DC Converter Installation, Operation and Maintenance Manual Table of Contents General... 1 Specifications... 1 Installation... 1 Theory of Operation... 2 Setup...
More informationTable of Contents. Safety Notices
IM0081 2018-01 Table of Contents Product Overview... 3 Principle of Operation... 3 Closed-Loop Servo Control with the FC-24 Controller... 4 Adjustments... 5 LED Status Indicators... 6 Installation...7
More informationModel 4800 O P E R AT I O N M A N U A L L O A D C E L L S U M M I N G T R A N S M I T T E R
O P E R AT I O N M A N U A L Model 4800 L O A D C E L L S U M M I N G T R A N S M I T T E R CALEX Manufacturing Company, Inc. Concord, California 94520 Ph: 925/687-4411 800/542-3355 Fax: 925/687-3333 http://www.calex.com
More informationInstruction Manual Model M Switch, DPDT, Manual Select
Instruction Manual Model 1582-70M Switch, DPDT, Manual Select November 2018 Rev 0 STATUS MODEL 1582 CROSS TECHNOLOGIES INC. MANUAL SELECT POWER Data, drawings, and other material contained herein are proprietary
More informationMODEL TI196 Current Loop Meter Installation and Operation Instructions
MODEL TI196 Current Loop Meter Installation and Operation Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description The Minco TI196 is a two-wire, loop-powered digital meter that accepts
More informationSealed Interface Control: EC20300
ISO 9001:2000 WITH DESIGN Certificate #02.002.1 Sealed Interface Control: EC20300 FEATURES: Weather tight control package Pulse Width Modulated output Waterproof altitude pressure and vapor release vent
More informationAMP-13 OPERATOR S MANUAL
AMP-13 OPERATOR S MANUAL Version 2.0 Copyright 2008 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24068 Phone: (540) 961-3576 Fax: (540) 953-3010 WARNING: Read instructions carefully
More informationAT Advanced Wire Tracer. Users Manual
AT-1000 Advanced Wire Tracer Users Manual AT-1000 Advanced Wire Tracer English Users Manual AT1000_Rev001 2008 Amprobe Test Tools. All rights reserved. Limited Warranty and Limitation of Liability Your
More informationRosemount 5408 and 5408:SIS Level Transmitters
Quick Start Guide 00825-0100-4408, Rev AD March 2018 Rosemount 5408 and 5408:SIS Level Transmitters Cone Antenna Quick Start Guide March 2018 1 About this guide This Quick Start Guide provides basic guidelines
More informationModel 1791 VHF Radio User's Manual
Model 79 VHF Radio User's Manual ALL WEATHER INC 65 NATIONAL DRIVE SACRAMENTO, CA 95834 WWW.ALWEATHERINC.COM 79 VHF RADIO USER'S MANUAL CONTENTS INTRODUCTION... Description... Transmitter Module... Power
More informationSignal Isolation Module. Instruction Manual SIM
Signal Isolation Module Instruction Manual SIM200-000 Table of Contents 1. General Description... 3 2. Specifications... 3 2.1 Electrical... 3 2.2 Physical... 4 3. Installation... 4 3.1 Wiring Guidelines...
More informationARBE-III Instruction Manual
ARBE-III Instruction Manual Introduction ARBE-III is a solid state, fully regulated, universal power supply designed specifically for use of pre 1930 s battery operated radios. Three electronically isolated
More informationINSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer
INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG
More informationUSER'S MANUAL DMR-6700
USER'S MANUAL Multimeter True RMS DMR-6700 CIRCUIT-TEST ELECTRONICS www.circuittest.com Introduction This meter measures AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency (electrical & electronic),
More informationUser's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters
User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationNEXUS NX50-1, -2 Servo Motor Installation. Fireye DESCRIPTION SAFETY INFORMATION
NEX-050 APRIL 8, 0 Fireye NEXUS NX50 -, - Servo Motor Installation DESCRIPTION This Manual describes the installation and operating instructions for the NX50 50Nm / 7 lb.-ft. servo motor. Other servo motor
More informationHydrogen Sulfide Transmitter Operator s Manual
65-2331-04 Hydrogen Sulfide Transmitter Operator s Manual Part Number: 71-0440 Revision: P1 Released: 9/15/17 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationMiniMe 2-Wire Ultrasonic Level Transmitter Model LU12/LU13/LU14 Owner s Manual
Warranty, Service & Repair To register your product with the manufacturer, go to the Flowline website for on-line registration. The website address is as follows: www.flowline.com. On-line Warranty Registration
More informationNemalux INSTALLATION INSTRUCTIONS APPLICATION 1-4
I N D U S T R I A L rev. A- INSTALLATION INSTRUCTIONS *PENDING* E77827 E77827 APPLICATION MR3 & MR6 Luminaires are suitable for use in the following areas as defined by the National Electrical Code (NEC)
More informationEchotel Trident 91S/92S Ultrasonic Level Switches
Echotel Trident 91S/92S Ultrasonic Level Switches D E S C R I P T I O N The Trident 91S/92S detects single or dual point level in a wide variety of liquid applications. It is available with either an ma
More informationE7000, E7500, and E ma Analog Transmitters
E7000, E7500, and E8000 4-20 ma Analog Transmitters Installation, Operation and Maintenance Manual 24512-00 Rev. 1.8 6/8/16 3255 W. STETSON AVENUE HEMET, CA 92545-7799 Tel (951) 652-6811 Fax (951) 652-3078
More informationEchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure
EchoSonic II Ultrasonic Level Transmitter LU23, LU28 & LU29 Series Quick Start NEMA 4X Enclosure QS300480 Rev B 2013 Flowline, Inc. All Rights Reserved Made in USA 10500 Humbolt Street, Los Alamitos, CA
More information34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009
User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent
More informationUser's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters
User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance
More informationK-FACTOR SCALER B & B
K-FACTOR SCALER B220-880 & B220-881 INSTALLATION & INSTRUCTION MANUAL 8635 Washington Ave. Racine, Wisconsin 53406 Technical Toll-Free: 877.722.4631 Sales Toll-Free: 800.235.1638 Phone: 262.639.6770 Fax:
More informationMODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT
MODEL UBP-10 UNIVERSAL IN-LINE TRANSDUCER AMPLIFIER BI-POLAR SUPPLY, 0-10 VOLT OUTPUT 2080 Arlingate Lane, Columbus, Ohio 43228 (614) 850-5000 Sensotec, Inc. 2080 Arlingate Lane Columbus, Ohio 43228 Copyright
More informationAC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español
Owner's Manual AC/DC Clamp Meter Model No. 82369 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationModel 9305 Fast Preamplifier Operating and Service Manual
Model 9305 Fast Preamplifier Operating and Service Manual This manual applies to instruments marked Rev 03" on rear panel. Printed in U.S.A. ORTEC Part No.605540 1202 Manual Revision B Advanced Measurement
More informationExplosion Proof Page/Talk Paging Amplifier
Industrial Communications Worldwide Explosion Proof Page/Talk Paging Amplifier Installation & Operation 7552-10 th Street. N.E. Calgary Alberta, Canada T2E W1 Ph: 403.25.3100 \ email:info@guardiantelecom.com
More informationInstallation, Operation and Maintenance Manual
TM M723 Rev. C Model 1050 Strain Gage Transmitter Installation, Operation and Maintenance Manual Table of Contents General... 1 Installation... 1 Specifications... 1 Wiring... 2 Setup and Operation...
More informationUSER MANUAL. Maxwell Technologies BOOSTCAP Energy Storage Modules. User Manual for 15V Modules: 20 F, 23 F, 53 F, 58 F 15 Volts DC
USER MANUAL Maxwell Technologies BOOSTCAP Energy Storage Modules User Manual for 15V Modules: 20 F, 23 F, 53 F, 58 F 15 Volts DC BPAK0020 P015 B1 BPAK0023 E015 B1 BPAK0052 P015 B1 BPAK0052 P015 B2 BPAK0058
More information200Amp AC Clamp Meter + NCV Model MA250
User's Guide 200Amp AC Clamp Meter + NCV Model MA250 Introduction Congratulations on your purchase of this Extech MA250 Clamp Meter. This meter measures AC Current, AC/DC Voltage, Resistance, Capacitance,
More informationKENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents
KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter
More informationInstruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)
Instruction Manual Model MLA & MLD Loop Powered Process Indicators Model MLD (Digital) Model MLA (Analog) 1. PREFACE The Model MLA and MLD field mounted indicators receive DC voltage or current signals
More informationInstallation & Operation Manual SAGA1-K Series Industrial Radio Remote Control
Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control Gain Electronic Co. Ltd. Table Of Contents Safety Considerations ------------------------------------------------------------2
More informationDUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER
OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Web Site: www..com
More informationSC-FI Series Frequency to Current Signal Conditioner
SC-FI Series Frequency to Current Signal Conditioner 99829 08/27/01 INDEX DESCRIPTION... 1 SPECIFICATIONS... 1 TYPICAL WIRING HOOKUP... 1 INPUT & OUTPUT SETTINGS... 2 "L" OPTION SPECIFICATIONS... 3 "L"
More informationUser's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330
User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330 Introduction Congratulations on your purchase of the Extech EX330 Meter. The EX330 offers AC/DC Voltage, AC/DC Current,
More informationUser s Guide HX94B SERIES. Temperature/Relative Humidity Transmitter. Shop online at omega.com SM
User s Guide Shop online at omega.com SM e-mail: info@omega.com For latest product manuals: www.omegamanual.info HX94B SERIES Temperature/Relative Humidity Transmitter omega.com info@omega.com Servicing
More informationPOWER SERIES Plus. Volt / Amp / Hertz. Digital Switchboard Meter. User s Manual IM2493VAF-3
POWER SERIES Plus Volt / Amp / Hertz Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology. Careful
More informationTMP-100 Turbine Meter Pulse Divider Circuit
NUFLO TM TMP-100 Turbine Meter Pulse Divider Circuit User Manual Manual No. 9A-100080245, Rev. 01 2008 Cameron International Corporation ( Cameron). All information contained in this publication is confidential
More informationOwner s Manual LSP38 38 Lawn Sweeper
Owner s Manual LSP38 38 Lawn Sweeper Manual Contents Safety Instructions Assembly Operation Maintenance Parts Warranty 2 4-13 2 11 14-15 16 Your Lawn Sweeper Congratulations on your purchase of a new Precision
More informationAC-TX Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker AC-TX128
70 Volt/100 Volt Transformer Panel for VR61 and VR62 Loudspeakers and the CLA37 Column Loudspeaker 70 Volt/100 Volt Transformer Panel for VR21 and VR51 Loudspeakers INSTRUCTION MANUAL 1. SAFETY INSTRUCTIONS
More informationUser s Guide HX93B SERIES. Temperature/Relative Humidity Transmitters. Shop online at omega.com
User s Guide HX93BD WALL MOUNT EASY M12 CONNECTION HX93BD(*)-D DUCT MOUNT Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info TH-RP remote probe with 3 m (10')
More informationDigital Voltage Detector 0-999kV Operating Instructions VD1000PTM
Digital Voltage Detector 0-999kV Operating Instructions VD1000PTM CONTENTS Limitation of Warranty and Liability 2 Product Safety Information 3 Design and Function Battery Replacement 4 Voltage Detection
More informationGlass Electrode Meter
Glass Electrode Meter INSTRUCTION MANUAL FOR Glass Electrode R/C Meter MODEL 2700 Serial # Date PO Box 850 Carlsborg, WA 98324 U.S.A. 360-683-8300 800-426-1306 FAX: 360-683-3525 http://www.a-msystems.com
More informationDANFYSIK A/S - DK-4040 JYLLINGE - DENMARK
2 TABLE OF CONTENTS PAGE 1. INTRODUCTION AND SPECIFICATIONS. 1.1 Introduction... 4 1.1.1 Working principle....4 1.2 Warranty...5 2. RECEIVING AND UNPACKING. 2.1 Receiving the goods....6 2.2 Instructions
More informationLPU-2127 User Manual
LPU-2127 User Manual Doc #9004169 Rev A1, 04/15 Table of Contents Introduction... iii Warranty and Warranty Restrictions... iv Chapter 1: Specifications and Options... 1 Dimensions...1 Specifications...
More informationMaster Reference Unit
Master Reference Unit Instruction Manual Model D10096-000 Driven by Excellence D.C. DRIVES, A.C. INVERTERS, SOLID STATE STARTERS, SYSTEM INTERFACE CIRCUITS AND ENGINEERED SYSTEMS Driven by Excellence D.C.
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationSignature Choral Riser Side Rail
Assembly/Owner s Manual Signature Choral Riser Side Rail Signature Choral 3-Step Riser with Optional Side Rail Signature Choral 4-Step Riser with Optional Side Rail CONTENTS Visit the Signature Choral
More informationFisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation
Instruction Manual 1052 Size 20 Actuator (H) Fisher 1052 Size 20 Diaphragm Rotary Actuator with H Mounting Adaptation Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications...
More informationUser s Guide. 400A AC/DC Clamp Meter. Model MA220
User s Guide 400A AC/DC Clamp Meter Model MA220 Introduction Thank you for selecting the Extech MA200 AC/DC Clamp Meter. This meter measures AC/DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
More informationBFS / BFSM SERIES Installation & Maintenance Manual
Introduction: The BFS / BFSM series electric actuators have battery backup modules for fail safe operation. The BFS series is for two position control and the BFSM series is for proportional control, both
More informationPRINCO MODELS L2610 & L2610R
Instrumentation designed with the user in mind INSTRUCTION MANUAL PRINCO MODELS L2610 & L2610R CONTINUOUS LEVEL TRANSMITTERS with NULL-KOTE PRINCO INSTRUMENTS INC. 1020 INDUSTRIAL BLVD. SOUTHAMPTON, PA
More informationOPERATORS MANUAL WEEKENDER STEEL LADDER RACK
OPERATORS MANUAL WEEKENDER STEEL LADDER RACK WWW.WEATHERGUARD.COM MODELS 1450 & 1475 1475 Shown INSTALLATION TIME Approximate installation time: 60 minutes (depending on truck equipment installation experience
More informationUser s Guide TX94A. Ultra-Miniature Temperature Transmitters. Shop online at omega.com
TM User s Guide Shop online at omega.com e-mail: info@omega.com For latest product manuals: www.omegamanual.info TX94A Ultra-Miniature Temperature Transmitters omega.com info@omega.com U.S.A. Headquarters:
More informationINSTRUCTIONS PS2500 POWER SUPPLY
INSTRUCTIONS PS2500 POWER SUPPLY The Hoefer PS 2500 Power Supply will furnished power to Constant Voltage or Constant Power modes of operation. It will accurately supply 0-2500 volts, 0-300 ma or 0-375
More informationAnalog Voltage Detector 1-450kV Operating Instructions VDAO450TM. Patent No. 6,275,022
Analog Voltage Detector 1-450kV Operating Instructions VDAO450TM Patent No. 6,275,022 CONTENTS Limitation of Warranty and Liability 2 Product Safety Information 3 Design and Function 4 Operating Procedure
More informationRK-CH4-4 Methane Transmitter Operator s Manual
65-2395RK-CH4-4 Methane Transmitter Operator s Manual Part Number: 71-0468 Revision: P1 Released: 10/17/18 RKI Instruments, Inc. www.rkiinstruments.com WARNING Read and understand this instruction manual
More informationC5000 & C5000NF PULSE INITIATOR. Introduction
C142-05, Page 1 952-361-3026, INC. (Fax) 952-368-4129 327 LAKE HAZELTINE DRIVE, CHASKA, MN 55318 800-328-0738 C5000 & C5000NF PULSE INITIATOR Introduction The MAXIGARD C5000 and C5000NF are designed to
More informationPotentiometer Control EC20200
Engineering & Manufacturing Solutions Potentiometer Control EC20200 APPLICATION: Proportionally control the speed of hydraulic motors and cylinders. ISO 9001:2008 WITH DESIGN Certificate #02.002.1 Features
More information200B Clipper Module User Manual
Trig-Tek 200B Clipper Module User Manual Publication No. 980954 Rev. A Astronics Test Systems Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 atsinfo@astronics.com
More informationKING-GAGE KING. ES2 Liquid Level Transmitter. Installation and Operation Instructions ma Liquid Level Transmitter EX-1834
Effective: April 2007 (Replaces January 2007) KING-GAGE 4-20 ma Liquid Level Transmitter ES2 Liquid Level Transmitter Installation and Operation Instructions Since 1937 KING E N G I N E E R I N G C O R
More informationTT881 Explosion-Proof Temperature Assembly Installation and Operating Instructions
TT881 Explosion-Proof Temperature Assembly Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Installation Thermowell, Head, and Sensor 1. Unscrew the connection
More information41P Portable Calibrator User Manual
Trig-Tek 41P Portable Calibrator User Manual Publication No. 980961 Rev. A Astronics Test Systems Inc. 4 Goodyear, Irvine, CA 92618 Tel: (800) 722-2528, (949) 859-8999; Fax: (949) 859-7139 atsinfo@astronics.com
More informationMINCO PRODUCTS, INC Commerce Lane, Minneapolis, Minnesota U.S.A. Telephone: (763) FAX: (763)
MINCO TT190 and TT230 2-wire Temperature Transmitters Installation and Operating Instructions INTRINSICALLY SAFE NON-INCENDIVE TT230 TT190 MINCO PRODUCTS, INC. 7300 Commerce Lane, Minneapolis, Minnesota
More informationHT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions
HT2 Humidity Transmitter HT2 Humidity and Temperature Transmitter Installation and Operating Instructions Tel: 763. 571.3121 Fax: 763. 571.0927 www.minco.com Description Model HT2 is a 2-wire temperature
More information1-830 SERIES DISPLACEMENT TRANSMITTER
1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com
More informationINSTRUCTION MANUAL (ATEX / IECEx)
INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING
More information