1 OPERATOR S MANUAL DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER Masibus Automation & Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar , Gujarat, India Web Site:

2 Contents (1) INTRODUCTION Description 1.2 Block Diagram 1.3 Product Ordering Code (2) SPECIFICATIONS 4 (3) INSTALLATION GUIDELINES 3.1 Terminal Connections 3.2 Connection Diagram 3.3 Mounting Details (4) OPERATION GUIDELINE Calibration Procedure (5) APPLICATION Importance of Isolation 5.2 Application Area (6) SAFETY / WARNING PRECAUTIONS 6.1 Safety Precautions 6.2 Warning Precautions (7)Trouble shooting 7 Figures & Tables Figure1: Block Diagram 3 Figure2: Terminal Connection 5 Figure3: Connection for CT Input 5 Figure4: Connection for PT Input 5 Figure5: Installation details 5 Figure6: Test Set up 6 Table1: Product ordering Code 3 Table2: Specification Warning Symbol The symbol calls attention to the operating procedure, practice or the like which if not correctly performed or adhered to, could result in personal injury or damage to or destruction of part or all of the product and system. Do not proceed beyond a warning symbol until the indicated condition are fully understood and met. Class-2 Type of instrument Class-2 Instrument is using Line & Neutral for Power Supply Input. Note: Information in this manual is subject to change without prior notice or permission. Purpose of The Manual This manual should be provided to the end user. Keep an extra copy or copies of the manual in a safe place. Read this manual carefully to gain a thorough understanding of how to operate this product before starting operation. This manual describes the functions of this product. Masibus does not guarantee the application of these functions for any particular purpose. The contents of this manual are subject to change without prior notice. Note: Information in this manual is subject to change without prior notice or permission. Page 2 of 7

3 1. INTRODUCTION 1.2. block diagram 1.1. Description AC Current & AC Voltage Transducers provide a reliable & accurate analog DC output proportional to the AC input from the secondary of potential and/or current transformers in control enclosures. The output is usually linked to remote monitoring equipment such as meters, recorders, PLC s, SCADA systems etc. Available only in single phase version, externally powered. Average Sensing, Zero-Based Input An economical & accurate means of current / voltage measurement on systems where the waveform is a pure sine wave. Device can also be used for non-critical applications with distorted waveforms, where high accuracy is not required. Calibrated to the RMS value of the sine wave. The plastic case Current/Voltage transducers (DA/DV Series) offer versatility & compactness when panel space is tight & can be mounted on a DIN rail The need for Isolation Safety isolation is important for both manufacturers and consumers. Its purpose is to electrically separate hazardous circuits and transient sources from users and to protect products and their surroundings. Galvanic isolation is the most popular method. Transformers and opto isolators are examples of galvanic isolation. Transformers use separate windings to magnetically convert power from inputs to outputs. Opto isolators convert input signals into light and then convert it back for the output signals. Figure1: Block Diagram 1.3. Product Order Code ENCLOSURE ABS DIN, Rail Mount AC Current Transducer AC Voltage Transducer CONFIGURATION DA DV Single Phase 1 Three Phase 3 INPUT Current Voltage 0-5A 0-150V 0 0-1A 0-90V 1 0-2A 0-300V V 3 OUTPUT 0-1mA (0-10,000 Ohms) 0 0-3mA (0-3,300 Ohms) 1 0-5mA (0-2,000 Ohms) mA (0-1,000 Ohms) mA (0-750 Ohms) 4 0-1V (180 Ohms minimum) 6 0-5V (500 Ohms minimum) V (1000 Ohms minimum) 8 1-5V (500 Ohms minimum) 9 Special SUFFIX (If Applicable) 110 VAC Aux Power EC 230 VAC Aux Power FC DC Aux Power 24VDC K1 DC Aux Power 48VDC K2 DC Aux Power 125VDC K3 DC Aux Power 220VDC K4 Special NO. Of Outputs Single Dual X X Keep Blank D For Example: DA114K4D is the ordering code for AC current transducer in a DIN rail, with a 0-1A input, a 4-20mA dual output & 220 Vdc aux. power. Table1: Product Ordering Code Page 3 of 7

4 2. SPECIFICATION: Item Specification Input Signal Input Signal for AC Current Transducer : 0-5A, 0-1A, 0-2A Input Signal for AC Voltage Transducer: 0-90V F.S. (Nom. 69V), 0-150V F.S. (Nom. 120V), 0-300V F.S. (Nom. 240V), 0-450V F.S. Input Over Range Capability: For Current : 150% more of rated Input. For Voltage : 75% to 120% of rated Input. Input Burden: For Potential Transformer max. Input burden is 0.2VA. For Current Transformer max. Input burden is 0.6VA. Consult factory if critical. Output Signal DC Current Output Range DC Voltage Output Range (Load Resistance) (Load Resistance) 0-1mA( Ω) 0-3mA(0-3000Ω) 0-5mA(0-2000Ω) 0-10mA(0-1000Ω) 4-20mA(0-750Ω) 0-1V (180Ω min.) 0-5V (500Ω min.) 0-10V (1000Ω min.) 1-5V (500Ω min.) External Calibration Adjustment : Zero: ±5% or more With Trim pot Span: ±10% maximum. Output Ripple Peak: Less than 75mV Peak Response Time : To 90%: 200ms max,to 99%: 400ms max Environmental Operating temperature: -10 C to +55 C Temp. Coefficient : ±0.01% per ºC. Insulation Resistance : Input/Output1/Output2/Power/Case. Greater than 200MΩ. Dielectric Test : Input/Output1/Output2/Power/Case 2000Vrms for one minute. Humidity : Up to 40 to 90 % RH non-condense. Compliance Voltage 18V Class index 0.5 Nominal Accuracy For Voltage Transducer:0.25% of rated full scale output from 10% to 110% of rated input range For Current Transducer:0.25% of rated full scale output from 5% to 110% of rated input range Usage Group III (-10 C 0 C.45 C +55 C) (IEC60688) Pollution Degree I (IEC ) OverVoltage Category CAT I (IEC ) External Power Supply: AC Aux. Supply : 110V AC, ±10%, 50Hz. 230V AC, ±10%, 50Hz. DC Aux. Supply : 24V DC, 48V DC, 125V DC, 220VDC ±10%. Power Consumption: For Current / voltage Output: Less than 6.0VA For Dual Output Less than 4.0VA For Single Output Enclosure ABS DIN Rail Mount Weight Approximately Kg. Physical Circuit boards: Copper claded laminate FR-4 Grade epoxy Glass. Construction Terminals : Metal Screw can accept up to 2.5 square mm wire. Case : Bayblend FR 1439/0240 modified ABS, Light gray. (RAL 7035) with fireproofing finish VL94 VO (1.6mm). Size : 60mm Width, 70mm Height, & Depth 112mm. Mounting : DIN RAIL mounting. Connections : Power, Input & Output as shown on the front sticker of the module. Table2: Specification Page 4 of 7

5 3. INSTALLATION GUIDELINES Connection for PT Input: 3.1. Terminal Connections: Figure2: Terminal Connection 1. Terminal 1&2: Output 1 2. Terminal 3 &4: Output2 3. Terminal 9&10: Power Supply Input AC Aux. Supply: 110V AC, ±10%, 50Hz. 230V AC, ±10%, 50Hz. DC Aux. Supply: 24V DC, 48V DC, 125VDC, 220VDC,±10%. 4. Terminal 7&8: Input 5. Terminal 5, 6, 11, 12: NC 3.2 Connection Diagram: All Dual Voltage Transducers DVXXXXX Series Figure4: Connection for PT Input Note: 1. Use>250V-1Amp Cable for Power Supply. 2. If cable has two parallel wires inside than isolation between them must be 2.5 KV Connection for CT Input: 3.3 Mounting Details: Recommended way of mounting is shown below. Distance between mounting of two transducers is more than 50mm. Front View: All Dual Current Transducers DAXXXXX Series Figure3: Connection for CT Input Figure5: Installation details Page 5 of 7

6 4. OPERATION GUIDELINES 4.1 CALIBRATION PROCEDURE Turn on the equipment & allow a minimum of 15 minutes warm up time. Connect the equipment as shown in figure. CALIBRATOR OSCILLOSCOPE TRANSDUCER UNDER TEST Figure 6: Test Setup RESISTANCE LOAD PRECISION DIGITAL MULTIMETER This equipment requires an external power source, connect to an appropriate source. Zero Offsetting: Set the calibrator correspond to min. value, adjust the Zero setting pot to the min. output on precision digital multimeter, also check for the variation of ±5% of full scale. Full Scale Calibration: Set the calibrator correspond to max. value, adjust the Span setting pot to the max. output on precision digital multimeter, also check for the variation of ±10% of output. Linearity Check: Change the current input from min. to max. in step of 25% & record all readings within accuracy of 0.25% of full scale. Output Ripple Check: Using the oscilloscope at 0.5 second sweep rate & appropriate AC range, measure the amount of ripple across the specified resistance, from centre line to peak. 5. APPLICATION 5.1 Important of Isolation In most processes there are pieces of electronic measurement and control equipment from many different manufactures. The signals from these instruments are interconnected to each other and to sensors, transducers and output devices connected in the process loop. In any such measurement and control system there are several problems that are likely to occur, all of which can be solved by incorporating the appropriate isolation between signals. 5.2 APPLICATION AREA: Measurement of most electrical Parameters. Conversion to standard dc output signals. Outputs suitable for PLC s. Use in control cabinets, Process Energy Measurement. 6 SAFETY / WARNING PRECAUTIONS 6.1 Safety Precautions Dangerous voltages capable of causing death are sometimes present in this instrument. Before installation or beginning of any troubleshooting procedures the power to all equipment must be switched off and isolated. Units suspected of being faulty must be disconnected and removed first and brought to a properly equipped workshop for testing and repair. Component replacement and interval adjustments must be made by a company person only. 6.2 Warning Precautions Before wiring, verify the label for correct model no. and options. Wiring must be carried out by personnel, who have basic electrical knowledge and practical experience. It is recommended that power of these units to be protected by fuses, circuit breakers or external over current rated at the minimum value possible. All wiring must confirm to appropriate standards of good practice and local codes and regulations. Wiring must be suitable for voltage, current, and temperature rating of the system. Beware not to over-tighten the terminal screws. Unused control terminals should not be used as jumper points as they may be internally connected, causing damage to the unit. Page 6 of 7

7 Verify that the ratings of the output devices and the inputs as specified in Chapter 7 are not exceeded. Upon receipt of the shipment remove the unit from the carton and inspect the unit for shipping damage. If any damage due to transit, report and claim with the carrier. Write down the model number and serial number for future reference when corresponding with our Customer Support Division. Do not use this instrument in areas such as excessive shock, vibration, dirt, moisture, corrosive gases or rain. The ambient temperature of the areas should not exceed the maximum rating specified. Provide power from a singlephase instrument power supply. If there is a lot of noise in the power line, insert an insulating transformer into the primary side of the line and use a line filter on the secondary side. As counter measures against noise, do not place the primary and secondary power cables close to each other. 7. TROUBLE SHOOTING GENERAL PROBLEMS: UNIT NOT TURNING ON The problem can be bad connection / power of incorrect rating. First check, power on terminal of the instrument itself if it is not present then the fault is in power chord. One must take care while dealing with Power wirings because it may create electrical shock. UNSTABLE READING Check for loose connections. First verify that all conventional instrumentation norms have been followed for wiring. Try using shielded cable for sensor input. Check for ripple on power supplies of Input section and Output sections. If power supplies have ripples, input voltage may be low or there is some failure on power supply card. Please note that this is an isolator, and the Input and Output sections are electrically isolated from each other. Therefore, any power supply measurements should be done with respect to proper grounds. OUTPUT NOT MATCHING WITH THE EXPECTED VALUE It is a normal tendency to doubt the instrument performance, when the Output is not matching the expected value. Kindly make sure that the output is really incorrect with respect to input signal, before attempting any recalibration. Account for measuring instrument s inaccuracies, lead errors and calibration errors. Care must be taken when measuring Output signal. An ordinary 3½ digit multimeter is used it can show reading which deviates from what the instrument is showing as the accuracy of the multimeter may not be as good as the that of the instrument. So use calibrating instrument of accuracy better than 0.1% for purpose of calibration. If the signal is still found to be out of tolerance, calibration should be attempted as described in the next section. VAGUE READING The reason can be reverse input connections. Page 7 of 7

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5

Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section 2, Calibration Calculations... 7 Calibration Procedure... 8 Section

More information

MODEL AT-10 ANALOG TRANSMITTER

MODEL AT-10 ANALOG TRANSMITTER MODEL AT-10 ANALOG TRANSMITTER INSTALLATION & OPERATING MANUAL Industrial Weighing Systems 9 Richmond Street Picton, Ontario K0K 2T0 Phone: 613-921-0397 Fax: 613-476-5293 Web: www.iwsystems.ca info@iwsystems.ca

More information

Installation and Operating Manual

Installation and Operating Manual GB Analog Weight Transmitter PS-1000 Installation and Operating Manual LIST OF CONTENTS Section 1, General information Introduction... 3 Description... 3 Specifications... 4 Wiring connections... 5 Section

More information

AC/DC Current Oscilloscope Probe Model SL261

AC/DC Current Oscilloscope Probe Model SL261 AC/DC Current Oscilloscope Probe Model SL261 USER MANUAL I ZERO 100 mv/a 10 mv/a OFF Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated

More information

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters

User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters User's Manual: Series 450T AC Current Input (External Sensor), AC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

AMM-1022 Digital Multimeter USER`S MANUAL

AMM-1022 Digital Multimeter USER`S MANUAL Digital Multimeter USER`S MANUAL www.tmatlantic.com CONTENTS 1. SAFETY INFORMATION.3 2. DESCRIPTION..6 3. SPECIFICATIONS.8 4. OPERATING INSTRUCTION..11 4.1 Voltage measurement...11 4.2 Current measurement

More information

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters

User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters User's Manual: Series 350T AC Current Input (External Sensor), DC-Powered Transmitters Table of Contents Page Introduction 1 Description 1 Specifications 2 Installation 3 Calibration 4 General Maintenance

More information

BC145 SIGNAL ISOLATOR BOARD

BC145 SIGNAL ISOLATOR BOARD BC145 SIGNAL ISOLATOR BOARD 4/17 Installation & Operating Manual MN1373 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com to download

More information

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH AC/DC LOW CURRENT CLAMP-ON METER CM605 ENGLISH User Manual Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

High Frequency SineWave Guardian TM Filter

High Frequency SineWave Guardian TM Filter High Frequency SineWave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference

More information

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions

SIMEAS-T. Operating Instructions Transducer without auxiliary power. 7KG6111 and 7KG6101. Operating Instructions Operating Instructions SIMEAS-T s Operating Instructions Transducer without auxiliary power for alternating current for alternating voltage for alternating voltage with expanded end range 7KG6111 and 7KG6101

More information

OPTITEMP TT 20 Technical Datasheet

OPTITEMP TT 20 Technical Datasheet OPTITEMP TT 20 Technical Datasheet Analog PC-programmable two-wire transmitters for Pt100 Efficient PC-configuration without recalibration Very stable output Very fast response time The documentation is

More information

High Frequency Sinewave Guardian TM Filter

High Frequency Sinewave Guardian TM Filter High Frequency Sinewave Guardian TM Filter 380V 480V TECHNICAL REFERENCE MANUAL FORM: SHF-TRM-E REL. April 2015 REV. 001 2015 MTE Corporation Caution Prior to start up; confirm the drive operation mode

More information

1 INTRODUCTION ORDER CODE / INFORMATION

1 INTRODUCTION ORDER CODE / INFORMATION INTRODUCTION ORDER CODE / INFORMATION 269/269Plus * * * * * * 269/269Plus SV D/O.4 ORDER CODE / INFORMATION Motor management relay Standard version Drawout version Phase CT Ground CT (required for D/O

More information

User s Manual Current Probe. IM E 2nd Edition IM E

User s Manual Current Probe. IM E 2nd Edition IM E User s Manual 700937 Current Probe 2nd Edition Introduction Thank you for purchasing the 700937 Current Probe. This Instruction Manual contains useful information about the instrument s functions and operating

More information

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual

Installation Manual DOC R1 Date: 05/27/99. Plug-in Meter Installation Manual Installation Manual DOC-4004-5015-R1 Date: 05/27/99 Plug-in Meter Installation Manual Document Number: Doc-4004-5015-R1 Document Release Date: 5/99 Copyright 1999 TeCom Inc. All rights reserved. No part

More information

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10 CONTENTS 1. SAFETY INFORMATION.1 2. DESCRIPTION..4 3. SPECIFICATIONS.6 4. OPERATING INSTRUCTION..9 4.1 Voltage measurement...10 4.2 Current measurement 10 4.3 Resistance measurement...12 4.4 Diode test.12

More information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information

D7F. Detects Changes in Machine. Vibration. Vibration Sensor with Linear Output or Manual Setting. Ordering Information with Linear Output or Manual Setting Detects Changes in Machine ON/OFF output can be set and checked quickly and easily from the vibration level meter. waveforms can be checked using the AC monitor output.

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS AC/DC high-voltage isolators for true rms measurement Input currents ranging from Iin = 100 ma AC to Iin = 5 A AC The Task In electrical systems, alternating currents from 100 ma to 5 A need to be recorded,

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 1st Edition. Yokogawa Electric Corporation User s Manual 701932 Current Probe Yokogawa Electric Corporation 1st Edition Foreword Revisions Thank you for purchasing the 701932 Current Probe. This user's manual contains useful information about the

More information

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009 User s Guide Publication number 34134-90001 April 2009 For Safety information, Warranties, Regulatory information, and publishing information, see the pages at the back of this book. Copyright Agilent

More information

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication:

RISH EM 3490 SS Kilowatt Hour Energy Meter With Rs485 RISH EM 3490 SS. Application : Product Features: Indication: Pulse Indication: Application : RISH Master 3490 SS is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy having auto-resetting 8 digit seven segment LED counter. The unit

More information

Keysight 1147B 50 MHz Current Probe. User s Guide

Keysight 1147B 50 MHz Current Probe. User s Guide Keysight 1147B 50 MHz Current Probe User s Guide Notices Keysight Technologies, Inc. 2000-2016 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval

More information

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM104 SERIES. SEM104P Pt100 Temperature Transmitter. SEM104TC Thermocouple Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM104 SERIES SEM104P Pt100 Temperature Transmitter SEM104TC Thermocouple Temperature Transmitter SEM104P 1 1.0 DESCRIPTION 2 2.0 SPECIFICATION 2 3.0 INSTALLATION 24 4.0

More information

MODEL: M2DYS SEN TRONIC AG

MODEL: M2DYS SEN TRONIC AG Super-mini Signal Conditioners Mini-M Series CURRENT LOOP SUPPLY Functions & Features Powers a 20 ma DC current loop Short circuit protection Applicable to smart transmitters CE marking UL approval Typical

More information

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE

Digital Panel Meter K3TE. Model Number Structure. Model Number Legend. Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input K3TE Digital Panel Meter K3TE Easy-to-use, Low-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display with

More information

Technical Data Sheet. x1000. kwh R Y B

Technical Data Sheet. x1000. kwh R Y B Technical Data Sheet x1000 Von kwh IRev 3600 imp /kwh R Y B is a compact multifunction instrument which is a 96mm x 96mm panel mounted kilowatt hour meter it measures active energy with class 1.0 accuracy

More information

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A. 3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2 (Code 7 71 071 to 7 71 083) INSTRUCTION MANUAL ( M 981 200 / 00 A ) (c) CIRCUTOR S.A. ----- MKT- MKT2 - ELECTRONIC METERS -------- M-981 200 --- Page Nº 2 3

More information

Theta 20A / 20V. Technical Data Sheet. Special Features

Theta 20A / 20V. Technical Data Sheet. Special Features Technical Data Sheet Theta 20A / 20V Theta 20A / 20V is used to measure and convert AC Voltage or Current input into a load independent DC current or voltage output signal. Special Features Available in

More information

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series

MODEL: W2DYS SEN TRONIC AG. Mini-MW Series MODEL: WDYS Space-saving Dual Output Signal Conditioners Mini-MW Series CURRENT LOOP SUPPLY Functions & Features Powers a 0 ma DC current loop Short circuit protection Applicable to smart transmitters

More information

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017

I P. /dt. di p V S Applications. Standards 1) IEC : 2007; IEC : ) IEC : 2016; IEC : 2017 Ref: ART-B22-D70, ART-B22-D125, ART-B22-D175, ART-B22-D300 Flexible clip-around Rogowski coil for the electronic measurement of AC current with galvanic separation between the primary circuit (power) and

More information

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W ADC5000 SERIES AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications 60W, 125W and 250 W Input voltage 230/115 VAC voltages 12, 24, 36 or 48 VDC Statistical MTBF >3 000

More information

DM-45 Digital Multimeter

DM-45 Digital Multimeter INSTRUCTION MANUAL DM-45 Digital Multimeter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Description The Greenlee DM-45 Digital

More information

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D T8211D 1 1. SAFETY INFORMATION BE EXTREMELY CAREFUL IN THE USE OF THIS METER. Improper use of this device can result in electric shock or destroy of

More information

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L High Performance Current Transducer IT 200-S ULTRASTAB For the electronic measurement of currents: DC, AC, pulsed..., with galvanic isolation between the primary circuit and the secondary circuit. I PM

More information

DVM1190 DIGITAL MULTIMETER

DVM1190 DIGITAL MULTIMETER DIGITAL MULTIMETER 1. Introduction Thank you for buying the. This digital multimeter has a large LCD, a data-hold function and a backlight. The device uses a very practical safety mechanism that keeps

More information

DIGIT & POINTER MULTIMETER

DIGIT & POINTER MULTIMETER CONTENTS DIGIT & POINTER MULTIMETER OPERATOR S MANUAL 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 1 1.2 DURING USE 2 1.3 SYMBOLS 3 1.4 MAINTENANCE 3 2. DESCRIPTION 4 2.1 NAMES OF COMPONENTS 4 2.2 FUNCTION

More information

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 50 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P TRMS High-Voltage Isolation Amplifiers / Shunt Isolators AC/DC high-voltage isolators for true rms measurement Input voltages up to Vin = 3600 V AC The Task In electrical systems, alternating voltages from

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-S ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

MACX MCR-UI-UI-UP(-SP)(-NC)

MACX MCR-UI-UI-UP(-SP)(-NC) Configurable 3-way isolating amplifier with safe isolation and wide-range power supply Data sheet 04247_en_02 PHOENIX CONTACT 203-04-0 Description MACX MCR-UI-UI 3-way isolating amplifiers are used to

More information

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES AS440 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A043Y697 (Issue 2) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...

More information

I Pr I P I OUT R L. Applications. Standards

I Pr I P I OUT R L. Applications. Standards Ref: ATO-XXX-B225-D10 I Pr = 10, 15, 16, 20, 30, 32, 50, 60, 63, 75 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between

More information

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired)

USER MANUAL. WBP314P71 active power transducer. (3-phase 4-wired) 2 WBP314P1 Active power transducer Safety claim The information in the safety claim of the equipment documentation is intended to ensure that equipment is properly installed in order to maintain it in

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 5502E Getting Started Supplement Issue: 3 Part Number: 4155211 Issue Date: 9/18 Print Date: November 2012 Page Count: 12 Revision/Date: This supplement contains information necessary to ensure

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 200-S ULTRASTAB I PM = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Closed loop (compensated)

More information

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter

INSTALLATION & OPERATING MANUAL. AT 08 Analog Transmitter INSTALLATION & OPERATING MANUAL AT 08 Analog Transmitter 2 SECTION I GENERAL INFORMATION The Model AT08 Analog Transmitters are ideal for use on systems having a full scale range of 10 mv, 20 mv, or 30

More information

MHz FUNCTION GENERATOR INSTRUCTION MANUAL

MHz FUNCTION GENERATOR INSTRUCTION MANUAL 72-6859 20MHz FUNCTION GENERATOR INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 EMC 5 Safety 4 Installation 5 Operation 7 Maintenance 8 www.tenma.com 1 Introduction This instrument

More information

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation

User s Manual Current Probe. IM E 2nd Edition. Yokogawa Electric Corporation User s Manual 701930 Current Probe Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the Current Probe (Model 701930). This instruction manual contains useful information

More information

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer 110 Toledo Street Farmingdale, NY 11735 USA http://www.netech.org 510-USER-Manual Rev3 10/29/2007 Dear User, We appreciate your purchase of the LKG

More information

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide

Agilent U1253B True RMS OLED Multimeter. Quick Start Guide Agilent U1253B True RMS OLED Multimeter Quick Start Guide The following items are included with your multimeter: Silicone test leads 4 mm probes Alligator clips Printed Quick Start Guide Rechargeable 8.4

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-340 MODEL: 61-342 Multimeter Service Information The Service Information provides the following information: Precautions and safety information Specifications

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 700-SB ULTRASTAB I PM = 700 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features ± 10 V voltage output

More information

SPECIFICATION, CONTROLS AND ACCESSORIES

SPECIFICATION, CONTROLS AND ACCESSORIES AS540 Automatic Voltage Regulator (AVR) SPECIFICATION, CONTROLS AND ACCESSORIES English Original Instructions A054N491 (Issue 1) Table of Contents 1. DESCRIPTION... 1 2. SPECIFICATION... 3 3. CONTROLS...

More information

DRG-SC Series Signal Conditioners

DRG-SC Series Signal Conditioners DRG-SC Series Signal Conditioners DRG-SC Series 245 Basic unit Models Available for Thermocouples, RTDs, DC Voltage and Current, Frequency, Strain Gage Bridge, AC Voltage and Current Field Configurable

More information

User Manual Digital Multimeter

User Manual Digital Multimeter User Manual Digital Multimeter model no.: MSR-R500 Questions or Concerns? support@etekcity.com visit etekcity.com for more products Safe and Proper Usage Thank you for purchasing the Etekcity MSR-R500

More information

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V)

n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) Tranducers for alternating current/voltage n True RMS measurement n Fully onsite programmable input voltage range (for CIP-V) and input current range (for CIP-I) n Available in single or dual output type

More information

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features:

RISH EM 3490 DS Dual Source Energy Meter (With All Display Parameters) RISH EM 3490 DS. Application : Product Features: (With All Display Parameters) Application : RISH EM 3490 DS measures important electrical parameters of Utility (in normal mode) & Generators (in Power back up) in three phase and single phase Network

More information

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

MODEL: M2SES SEN TRONIC AG [3] OUTPUT Super-mini Signal Conditioners Mini-M Series HIGH/LOW SELECTOR Functions & Features Monitors two DC input signals and transmits an output signal proportional to the higher or lower input CE marking UL

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MEMFLO MFT2 2-WIRE FLOW TRANSMITTER (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 DESCRIPTION Please read carefully! No liability can

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 605-S ULTRASTAB I PN = 600 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418

Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 Measuring Transducer MT4xx series Programmable AC Current Transducer MT418 o RMS AC current or frequency measurements o Current auto range measurements up to 12 A o Frequency measurement range 16 400 Hz

More information

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use True RMS Digital Multimeter DVM98 1 Safety information This multimeter has been designed according to IEC - 1010 concerning electronic measuring instruments with an overvoltage category (CAT II) and pollution

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV. MS8250A/B DIGITAL MULTIMETER OPERATION MANUAL AUTO DC AC REL hfe PCLINK % C F kmωkz nµmfav MS8250A DIGITAL MULTIMETER Auto Power Off RANGE REL HOLD FUNC NCV A ma OFF 10A A ma 10A FUSED 600V CAT IV COM

More information

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 (ENG) DECEMBER 2017 USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2 ISOLATOR - SIGNAL CONVERTER TYPE SP 11 CURRENT

More information

Model DIGITAL MULTIMETER

Model DIGITAL MULTIMETER Model 57070 DIGITAL MULTIMETER INSTRUCTION MANUAL SAFETY INFORMATION To ensure safe operation, and in order to exploit to the full the functionality of the meter, please follow the directions in this section

More information

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications. Current Transducer IT 205-S ULTRASTAB I PN = 200 A For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Features Wide operating temperature

More information

WATT TRANSDUCER. Instruction Manual

WATT TRANSDUCER. Instruction Manual WT 9200 WATT TRANSDUCER Instruction Manual IM-2 September 2003 USA: 6428 Ridglea Drive, Watauga, Texas 76148 Tel/Fax 1-817-427-2060/2067 E-mail: wes@westecinstruments.com SPECIFICATIONS Power Supply Input

More information

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8

I P I OUT R L. Applications. Standards. N 52.D ; Page 1/8 Ref: ATO-10-B225-D10/SP3 r = 10 A ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the

More information

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com Model ST-9933 True RMS Autoranging Digital Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-8 Technical...4-5 Accuracy...5-8 Display Description...

More information

CLAMP-ON METER 670. User Manual

CLAMP-ON METER 670. User Manual CLAMP-ON METER 670 675 E N G L I S H User Manual Certificate of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments

More information

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484

Converter. Specifications/Instructions. General. Features. Specifications. Dimensions AB-6484 AB6484 Specifications/Instructions Converter General Model RYY792X series of s offer compact, spacesaving, easy installation with its plugin structure. Each model is modularized for a particular function.

More information

Agilent 1147A 50 MHz Current Probe

Agilent 1147A 50 MHz Current Probe Agilent 1147A 50 MHz Current Probe User s Guide Publication number 01147-92006 January 2008 For Safety information, Regulatory information, and publishing information, see the pages at the end of this

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-920 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration

More information

SEPARATOR P20G TYPE USER S MANUAL

SEPARATOR P20G TYPE USER S MANUAL SEPARATOR P20G TYPE USER S MANUAL 1 2 Contents 1. APPLICATION... 5 2. SEPARATOR SET... 5 3. OPERATIONAL SAFETY... 6 4. FITTING... 7 4.1. Fixing Way... 7 4.2. External Connection Diagrams... 8 5. SERVICE...

More information

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL

HI 2204LT Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Loop Powered Level Weight Transmitter OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com

More information

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL Table of Contents TITLE PAGE 1. GENERAL INSTRUCTIONS 1 1.1 Precaution safety measures 1 1.1.1 Preliminary 1 1.1.2 During use 2 1.1.3 Symbols

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com #61-732 #61-736 400 AAC Clamp Meter Instruction Manual AC HOLD APO DC KMΩ mva WARNING Read First: Safety Information Understand

More information

AD-8100 & AD-8200 Servo Amplifiers

AD-8100 & AD-8200 Servo Amplifiers Instruction Manual IM-0607 AD-8100 & AD-8200 Servo Amplifiers Table of Contents General Information... 2 Basic Models... 3 Specifications... 3 Installation Wiring... 3 Setup & Calibration... 4-6 Troubleshooting

More information

User's Guide. AC Circuit Load Tester. Model CT70

User's Guide. AC Circuit Load Tester. Model CT70 User's Guide AC Circuit Load Tester Model CT70 Introduction Congratulations on your purchase of the CT70 AC Circuit Load Tester. This device can detect circuit and wiring problems such as: Poor ground

More information

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49 TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument True RMS measurement User-friendly programing Four different types for optimal specification RS485 interface For 3- or 4-wire connection Compact

More information

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual. Manual Title: 550A Getting Started Supplement Issue: Part Number: 415509 Issue Date: 9/18 Print Date: November 01 Page Count: 19 Revision/Date: This supplement contains information necessary to ensure

More information

MINI MCR-SL-UI-I-LP-NC

MINI MCR-SL-UI-I-LP-NC 2-way isolation amplifier Data sheet 105263_en_02 PHOENIX CONTACT 2013-12-13 1 Description The configurable 2-way isolation amplifiers are used to electrically isolate, convert and filter standard signals.

More information

CEC VIBRATION TRANSMITTER

CEC VIBRATION TRANSMITTER CEC 1-808 VIBRATION TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com E-mail:

More information

Phase-sequence Phase-loss Relay

Phase-sequence Phase-loss Relay Phase-sequence Phase-loss Relay K8AB-PH Three-phase Phase-sequence Phase-loss Relay Using Voltage Detection Method Prevents reverse motor rotation due to incorrect wiring. Distinguishes between positive

More information

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active Technical manual BA 0318 Signal converter Isolation amplifier active for galvanic isolation, conversion and adjustment of electrical standard signals Evaluable input signals Direct voltage 0...10V / 0...1V

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4. An American Control Electronics Brand PCM4 SERIES PCM4 USER MANUAL www.minarikdrives.com Dear Valued Consumer: Congratulations on your purchase of the PCM4 Series isolation card. This User Manual was created

More information

WATTNODE Pulse Output Installation and Operation Manual

WATTNODE Pulse Output Installation and Operation Manual WATTNODE Pulse Output Installation and Operation Manual Continental Control Systems http://www.ccontrolsys.com Rev 1.20dUL Information in this document is subject to change without notice. No part of this

More information

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES)

ALPHA 20 MULTIFUNCTION METER (ALPHA SERIES) Alpha Series www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters Shunts ALPHA

More information

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B

PEAKTRONICS AMC-103 ADDITIONAL FEATURES. AC Motor Controller, 2A AMC-103 AMC-103A AMC-103B PEAKTRONICS The Peaktronics AC Motor Controller is a compact module that is intended for controlling small AC actuator motors of up to 2A. The is very well suited for applications where space constraints

More information

MODEL 421 Over/Under Motor Load Monitor

MODEL 421 Over/Under Motor Load Monitor MODEL 421 Over/Under Motor Load Monitor Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or, Single-phase or 3-phase Built-in Trip and Restart

More information

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C.

VariTrans P Compact automation solutions can be implemented thanks to the 17.5 mm modular housing and operation at temperatures up to 70 C. ProLine Interface Technology Transducers for High Voltage / Shunt Applications Compact high voltage transducers with VariPower broad-range power supply and genuine calibrated range selection. The Task

More information

Integra 1560 and 1580 Digital Transducer Systems

Integra 1560 and 1580 Digital Transducer Systems Integra 1560 and 1580 multi function transducers provide high accuracy

More information

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK 2 TABLE OF CONTENTS PAGE 1. INTRODUCTION AND SPECIFICATIONS. 1.1 Introduction... 4 1.1.1 Working principle....4 1.2 Warranty...5 2. RECEIVING AND UNPACKING. 2.1 Receiving the goods....6 2.2 Instructions

More information

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS CONTENTS MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS 1. SAFETY INFORMATION 1 1.1 PRELIMINARY 2 1.2 DURING USE 3 1.3 SYMBOLS 5 1.4 MAINTENANCE 6 2. DESCRIPTION 8 2.1 NAMES OF COMPONENTS 9

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information