... for hydraulic and general applications in hazardous areas
|
|
- Terence Hicks
- 5 years ago
- Views:
Transcription
1 ATEX Approved Inductive... for hydraulic and general applications in hazardous areas
2 Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified isolation amplifier Inductive Namur sensors consist essentially of an oscillator an oscillator coil which can be damped an a demodulator. These sensors can be used in potentially explosive systems or areas based on their ATEX designation (when used a suitable isolation amplifier). Note! Before construction, installation and startup please familiar yourself the user's guide to be found at You must also follow the instructions contained in the EU Type Examination Certificate of the BVS and PTB. Housing size Mounting Rated operating distance s n Assured operating distance s a Namur Rated operational voltage U e Rated insulation voltage Ui Current draw: open (target detected) conducting (target t detected) Rated series resistance RV Polarity reversal protected Type of protection "intrinsically safe" Ambient temperature range T a Frequency of operating cycles f Function indicator Housing material Material of sensing face No. of wires cross-section Recommended Ex-Zone Conformity EC Type Examination Certificate Designation Maximum internal capacitance Maximum internal inductance to approved intrinsically safe circuits the highest values * Power limited through use of an approved intrinsically safe switching amplifier Wi diagrams BES G06.../M08... BES M12.../M18.../M
3 NAMUR Inductive DC 2-wire, 6.5 mm, M8, M12, M18, M30 s n 1 mm, 4 mm, 8 mm, 15 mm 6.5 mm 1 mm mm M8 1 1 mm mm 4 mm mm M mm mm M mm mm BES G06MD-GNX10B-EV02-EEX BES M08MD-GNX10B-EV02-EEX BES M12ME-GNX40B-S04G-EEX BES M18ME1-GNX80B-S04G-EEX BES M30ME1-GNX15B-S04G-EEX current change ( trigger function) * current change ( trigger function) * current change ( trigger function) * current change ( trigger function) * current change ( trigger function) * 700 Hz 400 Hz 100 Hz 2 m cable PVC mm² 2 m cable PVC mm² BKS-S 10-3/BKS-S 8-3 BKS-S 10-3/BKS-S 8-3 BKS-S 10-3/BKS-S 8-3 BVS 05 ATEX E 163 PTB 05 ATEX nf 0.07 mh BVS 05 ATEX E 163 PTB 05 ATEX nf 0.07 mh 210 nf mh 200 nf 0.19 mh 230 nf 0.21 mh 3
4 Type of protection "intrinsically safe" Inductive DC 2-wire Block style housings s n 20 mm, 35 mm Housing size Mounting Rated operating distance s n Assured operating distance s a NAMUR mm Unicompact 20 mm mm mm Unicompact n- 35 mm mm Wi diagram Namur BES Q40KFU-GNX20B-S92G-EEX BES Q40KFU-GNX35F-S92G-EEX Shield 1 to Namur safety switching amplifier 2 to Namur safety switching amplifier 5 Potential compensation, body Rated operational voltage U e Rated insulation voltage Ui Current draw: open (target detected) conducting (target t detected) Rated series resistance RV Polarity reversal protected current change ( trigger function) * current change ( trigger function) * Ambient temperature range T a Frequency of operating cycles f Function indicator Housing material Material of sensing face 200 Hz PPE/PPS PPE 100 Hz PPE/PPS PPE Recommended Ex-Zone Conformity EC Type Examination Certificate BKS-S BKS-S Designation Maximum internal capacitance Maximum internal inductance to approved intrinsically safe circuits the highest values * Power limited through use of an approved intrinsically safe switching amplifier Ex II 2G EEx ia IIB T6 250 nf 0.45 mh Ex II 2G EEx ia IIB T6 220 nf 0.71 mh Permissible installation types Rated operating distance sn 20 mm 35 mm permitted 4
5 NAMUR high pressure rated Type of protection "intrinsically safe" Inductive Housing size Mounting Rated operating distance s n Assured operating distance s a DC 2-wire M12 s n Ignition class "intrinsically safe" when used together a suitable certified isolation amplifier Inductive Namur sensors consist essentially of an oscillator an oscillator coil which can be damped an a demodulator. This high-pressure rated sensor is used among other things for end-of-stroke monito on hydraulic cylinders or position sensing on valves. It may be used in explosionrisk equipment or Zone 1 and Zone 2 areas (in conjunction a suitable isolating amplifier). Note! Before construction, installation and startup please familiar yourself the user's guide to be found at You must also follow the instructions contained in the EU Type Examination Certificate of the PTB. Namur Rated operational voltage U e Rated insulation voltage Ui Rated series resistance RV Permissible series resistance R V Output signal: open (target fully detected) conducting (target fully undetected) Polarity reversal protected < 9 V Repeat accuracy R Ambient temperature range Ta Frequency of operating cycles f Function indicator Housing material Material of sensing face Recommended /spare part number Support /spare part number Pressure rated (for hydraulics) up to BES S 266-S Ω current change ( trigger function) 4 ma C 1000 Hz POM BKS-S 10-3/BKS-S / / Ex-Zone Conformity EC Type Examination Certificate Designation Effective internal capacitance Effective internal inductance maximum input power Pi :1994 PTB 01 ATEX 2207 X Ex II 2 G EEx ia IIC T6 30 nf 0.5 mh 200 mw Protected against reversal of plus and minus to U B = 9 V. For additional data see EC Type Examination Certificate. Wi diagram 5
6 Inductive Type of protection "n" Pressure rated sensors Explosion protected Note! Housing size Mounting Rated operating distance s n Assured operating distance s a Devices in this category are for use in areas where an explosive atmosphere cant be formed under rmal conditions. If it does occur, then it must be only seldom and for a short period of time. Before construction, installation and startup please familiar yourself the user's guide to be found at These sensors are rated Class II Category 3G. PNP NO Rated operational voltage U e Voltage drop Ud at Ie Rated insulation voltage Ui Rated operational current I e No-load supply current I 0 max. Off-state current Ir Polarity reversal protected Short circuit protected Permissible load capacitance Type of protection "n" Repeat accuracy R Ambient temperature range Ta Frequency of operating cycles f Utilization category Function indicator Housing material Material of sensing face Recommended /spare part number Support /spare part number Pressure rated (for hydraulics) up to Ex-Zone Conformity Designation Wi diagram 6
7 high pressure rated Inductive M18 1 DC 3-wire M12, M18 s n BES S 135-NEX-S4-D BES S 249-NEX-S4-D BES S 262-NEX-S4-D BES S 308-NEX-S4-D 24 V DC 1.5 V 200 ma 10 ma 10 µa 0.5 µf 24 V DC 2 V 200 ma 8 ma 10 µa 1 µf 24 V DC 2 V 200 ma 8 ma 10 µa 1 µf 24 V DC 2 V 200 ma 8 ma 10 µa 1 µf C 1000 Hz DC C DC C DC C DC 13 EP EP EP EP BKS-S 19-1/BKS-S / / BKS-S 19-1/BKS-S / / BKS-S 19-1/BKS-S / / BKS-S 19-1/BKS-S / / DIN EN 50014:2000 DIN EN Ex II 3G EEx na II T4 X DIN EN 50014:2000 DIN EN Ex II 3G EEx na II T4 X DIN EN 50014:2000 DIN EN Ex II 3G EEx na II T4 X DIN EN 50014:2000 DIN EN Ex II 3G EEx na II T4 X 7
8 Inductive Connectors Connector Type Application BKS-S 10 straight female tubular plug-in s S 4 (max. 4-pin) BKS-S 8 angle female tubular plug-in s S 4 (max. 4-pin) BKS-S straight female plug-in sensors BES Q EEX No LED BKS-S 10-3 BKS-S 8-3 BKS-S Manufacturer Cable No. of wires cross-section Cable diameter min. Ambient temperature range Ta Binder V DC for user assembly 4 max mm² mm screw terminals C Binder V DC for user assembly 4 max mm² mm screw terminals C Binder V DC for user assembly 5 max mm² mm screw terminals C Connector Type Application BKS-S 19 straight female tubular plug-in sensors NEX-S 4 BKS-S 20 angle female tubular plug-in sensors NEX-S 4 8 No LED, NO Manufacturer Supply voltage U B Cable Cable color No. of wires cross-section Ambient temperature range T a Cable length 10 m on request. BKS-S 19-1-PU-03 Lumberg 3 m molded-in black mm² C BKS-S 20-1-PU-03 Lumberg 3 m molded-in black mm² C Balluff GmbH Schurwaldstrasse Neuhausen a.d.f. Germany Phone Fax balluff@balluff.de No E. Edition 0609; Subject to modification. Replaces edition 0604.
Distance Sensors BOD 26K.... with optional Master-Slave-Mode
Distance... with optional Master-Slave-Mode Laser Distance The Balluff distance sensor not only detects the presence of objects, but can also indicate their precise position or location. This means the
More informationInductive sensor slot-type SI2-K08-AP7
SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type
More informationVTM Local Display Unit with Frequency and Analogue Output
Küppers Elektromechanik GmbH Flow Meters Liebigstr. 2 D-85757 Karlsfeld Phone +49 81 31/59 39 10 Fax + 49 81 31/9 26 04 VTM Local Display Unit with Frequency and Analogue Output The VTM is a programmable
More informationMiniature resistance thermometer Explosion-protected version Model TR34, thread-mounted
Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction
More informationIndicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN
Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm
More informationKSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays
KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit
More informationSALES SERVICE +358 (0)
SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationDMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)
DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationGlass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.
General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle
More informationDS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor
GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent
More informationOperating Instructions
Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationLimit switch attachments DAPZ
Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationIntrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications
More informationTR 104, TR 104-Ex Rail mounted Temperature Transmitters
Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationResistance thermometer Model TR30, compact design
Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationIntrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751
Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable
More informationPositioner with HART Communication Type 3780
Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels
More informationConnection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition
solated switch amplifier Output: relay Connection Control circuit EEx ia C 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short-circuit LK and interruption LB) with LED indicator
More informationOperator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique
Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationFieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex
Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationKFS. Flap-type flow meter. Design and range of application
Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is
More informationMagnetoinductive SMARTSENS BIL. Magneto-inductive. Position Sensors Contents
SMARTSENS Contents Magneto-inductive magneto-inductive position sensors are compact distance sensors for detecting positions up to 160 mm. The magneto-inductive analog position sensor measures without
More informationSINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationLevel and Pressure. Product Information. Vibrating level switches
Level and Pressure Product Information Vibrating level switches Contents Contents 1 Product description 1.1 VEGAVIB... 3 1.2 VEGASWING... 3 2 Function and application 2.1 Functional principle... 5 2.2
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationSINEAX / EURAX 2I1 Passive DC signal isolator
SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages
More informationLF Conductivity Measuring Probe
LF Conductivity Measuring Probe Contents 1 General 1.1 Introduction 1.2 Application range 2 Safety 2.1 Warnings and symbols 3 Transport and storage 4 Application 5 Measuring principle 6 Assembly 7 Construction
More informationConnection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition
Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω
More informationProcess transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm
Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant
More informationED701 General Industry Pressure Transmitter
ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationDesign and applications
Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated
More informationLevel Limit Switch nivotester FTL 370, FTL 372
Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationOEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted
Temperature OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 11 Applications Machine building, plant and vessel construction
More informationCATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX
CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX Registration No.: 1327-1 Testing laboratory accredited according to DIN EN 451 Reg.-No. DAT-P-48/95- For all transactions, the newest version
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More informationISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES
ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services
More informationAssembly. Front view. HiC2441. SL2 1b. Termination Board
SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting
More informationATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier
Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer
More informationRail mounted Temperature Transmitter TH102/TH102-Ex
Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples
More informationCertified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver
Certified according to DIN EN ISO 9001 Technical Datasheet FOP 0 and OPTV Fibre-Optic Amplifier and Receiver Description... 3 Technical Data... 3 Electrical Connections... 7 Ordering Information... 8 Marking...
More informationR88000 T (including ATEX)
INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:
More informationPage Type Resolution (mm) min. max. Output
Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationTÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.
GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More informationSITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009
Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter
More informationResistance Thermometers Model Series TR7X0, Sheathed Design
Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features
More informationUser manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD
User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3
More informationExpert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters
Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications
More informationTemperature Transmitters TMT 136, TMT 137
Technical Information TI 066R/09/en Part No. 51000855 Temperature Transmitters TMT 136, TMT 137 For Pt100 Resistance Thermometers 2-wire head transmitter Standard- and instrinsically safe versions Head
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationFOR RELIABLY MEASURING +
in(f)a22 ina05-09 ina14 PROXIMITY SWITCHES FOR RELIABLY MEASURING + EVALUATING MOVEMENTS T H E PROXIMITY SWITCHES O F T I E F E N B A C H C O N T R O L S Y S T E M S >>> HAVE BEEN ESPECIALLY DEVELOPED
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationTrimod Besta Level Switch type I 8 / IE9 8
Besta AG, CH8610 Uster / Switzerland Issue : November 2008 Page 1/8 Trimod Besta Level Switch type I 8 / IE9 8 for use in intrinsically safe installation acc. to directive 94/9/EC (ATEX) Contents 1. Safety
More informationCertified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier
Certified according to DIN EN ISO 9001 Technical Datasheet EWS Intrinsically Safe Supply and Separation Amplifier Description... 3 Technical Data... 3 Options... 7 Notes... 7 Connections... 8 Ordering
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationIntrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic pressure measurement Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA data sheet PE
More informationOEM radar transmitter, for aggressive media level measurement
OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type
More informationLevel Measurement silometer FMX 570
Technical Information TI 01F/00/en Level Measurement silometer FMX 570 Measurement of liquids and bulk solids Suitable for explosion hazardous areas For use with capacitance and hydrostatic probes The
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationResistance thermometer Model TR30, compact design
Temperature Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 for further approvals see page 8 Applications Machine building, plant and vessel construction Propulsion technology,
More informationIntrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F
Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,
More informationSINEAX B 811 Power Pack with additional Functions
SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationD1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater
D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More information