CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

Size: px
Start display at page:

Download "CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX"

Transcription

1 CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ATEX

2 Registration No.: Testing laboratory accredited according to DIN EN 451 Reg.-No. DAT-P-48/95- For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI shall apply, along with the supplementary conditions extended reservation of proprietary rights, together with the supplements listed on our order confirmations and/or invoices. All specifications are subject to change without notice. Reprint, even in part, only with our consent. RECHNER Germany 11/24G - Printed in EU, all rights reserved. Edition November 24 With publication of this catalogue all former printed catalogues about RECHNER isolating switching amplifiers and power supplies are invalid. All specifications are subject to change without notice. (11/24) 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

3 CATALOGUE ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES Isolating switching Amplifier / ATEX General information SERIES N-131/ Data sheet:... N-131/ V AC N-131/ V AC N-131/ V DC N-131/ V AC N-131/ V AC N-131/ V DC N-131/2-E V DC N-13/4...2-IL Power supplies EG General information SERIES EG Data sheet:... EGI /23 V AC EGII /23 V AC EGI-13-TD 115/23 V AC EGI-13-MM 115/23 V AC EGIII-13 24/48 V AC 115/23 V AC selection... in article number order and type description order All specifications are subject to change without notice. (5/24) RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 3

4 SERIES N The Series N isolating switching amplifiers transmit switching operations from an intrinsically safe control circuit to a non-intrinsically safe active current circuit. The control units are designed according to NAMUR-DIN or EN intrinsically safe and according to EN 514 and EN 52 [EExia] II C. The conformity is certified in Germany by TÜV-NORD. Power pack, switching amplifier, electronic evaluation unit and output relay are all integrated in the 22 mm sized housing. The units are EMV-approved according to IEC 81-2 to 5. Quick mounting is possible on profile according to DIN LED displays are integrated in the front plate for stand-by (green), state of output (yellow) and wire-break/shortcircuit of the sensor cable (red). The isolating switching amplifiers can be actuated by NAMUR sensors, e.g. our series IAS-3... and KAS- 4..., or by mechanical contacts. All specifications are subject to change without notice. (8/24) 4 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

5 6N5 N-131/1-1 Isolating Switching Amplifier N-131/ V AC II(1) G D [EEx ia] IIC N-131/1-1 Certificate: TÜV 2 ATEX 1869 N5 To connect one NAMUR-Sensor or potential-free mechanical contact. NAMUR sensors have to be connected to terminal 5 (+) with the brown wire and 7 (-) with the blue wire. Mechanical contacts also have to be connected to 5 and 7. A wirebridge has to be connected between 5 and 6, for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS Technical data voltageg (U ) 23 V AC + 1% Hz rating each relay AC max. rating each relay DC max. 1 x change-over contact potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/1-1 N5 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green All specifications are subject to change without notice. (8/24) housing: IP 3 : IP 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 5

6 6N6 N-131/1-2 Isolating Switching Amplifier N-131/ V AC II(1) G D [EEx ia] IIC N-131/1-2 Certificate: TÜV 2 ATEX 1869 N6 To connect one NAMUR-Sensor or potential-free mechanical contact. NAMUR sensors have to be connected to terminal 5 (+) with the brown wire and 7 (-) with the blue wire. Mechanical contacts also have to be connected to 5 and 7. A wirebridge has to be connected between 5 and 6, for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS Technical data voltage (U ) 115 V AC + 1% Hz rating each relay AC max. rating each relay DC max. 1 x change-over contact potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/1-2 N6 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1,5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green housing: IP 3 : IP 2 All specifications are subject to change without notice. (8/24) 6 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

7 6N7 N-131/1-1 Isolating Switching Amplifier N-131/ V DC II(1) G D [EEx ia] IIC N-131/1-1 Certificate: TÜV 2 ATEX 1869 N7 To connect one NAMUR-Sensor or potential-free mechanical contact. NAMUR sensors have to be connected to terminal 5 (+) with the brown wire and 7 (-) with the blue wire. Mechanical contacts also have to be connected to 5 and 7. A wirebridge has to be connected between 5 and 6, for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS Technical data voltage (U ) V DC rating each relay AC max. rating each relay DC max. 1 x change-over contact potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/1-1 N7 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green All specifications are subject to change without notice. (8/24) housing: IP 3 : IP 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 7

8 6N1 N-131/2-1 Isolating Switching Amplifier N-131/ V AC II(1) G D [EEx ia] IIC Certificate TÜV 2 ATEX 1869 Technical data N-131/2-1 N1 To connect two NAMUR-Sensors or potential-free mechanical contacts. NAMUR sensors have to be connected to 1 or 5 (+) with the brown wire and 3 or 7 (-) with the blue wire. Mechanical contacts also have to be connected to 1, 3 (channel 2) or 5, 7 (Channel 1). A wire-bridge has to be connected between 1, 2 (channel 2) or 5, 6 (channel 1), for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS voltage (U ) 23 V AC + 1% Hz rating each relay AC max. rating each relay DC max. 2 x change-over contacts potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/2-1 N1 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green housing: IP 3 : IP 2 All specifications are subject to change without notice. (8/24) 8 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

9 6N2 N-131/2-2 Isolating Switching Amplifier N-131/ V AC II(1) G D [EEx ia] IIC N-131/2-2 Certificate: TÜV 2 ATEX 1869 Technical data N2 To connect two NAMUR-Sensors or potential-free mechanical contacts. NAMUR sensors have to be connected to 1 or 5 (+) with the brown wire and 3 or 7 (-) with the blue wire. Mechanical contacts also have to be connected to 1, 3 (channel 2) or 5, 7 (channel 1). A wire-bridge has to be connected between 1, 2 (channel 2) or 5, 6 (channel 1), for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS voltage (U ) 115 V AC + 1% Hz rating each relay AC max. rating each relay DC max. 2 x change-over contacts potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/2-2 N2 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green All specifications are subject to change without notice. (8/24) housing: IP 3 : IP 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 9

10 6N3 N-131/2-1 Isolating Switching Amplifier N-131/ V DC II(1) G D [EEx ia] IIC N-131/2-1 Certificate: TÜV 2 ATEX 1869 Technical data N3 To connect two NAMUR-Sensors or potential-free mechanical contacts. NAMUR sensors have to be connected to 1 or 5 (+) with the brown wire and 3 or 7 (-) with the blue wire. Mechanical contacts also have to be connected to 1, 3 (channel 2) or 5, 7 (channel 1). A wire-bridge has to be connected between 1, 2 (channel 2) or 5, 6 (channel 1), for switching off the wire-break/shortcircuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS voltage (U ) V DC rating each relay AC max. rating each relay DC max. 2 x change-over contacts potential-fre e 25 V AC/ 5 A/ 1 VA 24 V DC/ 8 A/ 5 W N-131/2-1 N3 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN C red/yellow and green housing: IP 3 : IP 2 All specifications are subject to change without notice. (8/24) 1 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

11 6N4 N-131/2-E-1 Isolating Switching Amplifier PNP N-131/2-E V DC II(1) G D [EEx ia] IIC Certificate: TÜV 2 ATEX 1869 Technical data To connect two NAMUR-Sensors or potential-free mechanical contacts. NAMUR sensors have to be connected to 1 or 5 (+) with the brown wire and 3 or 7 (-) with the blue wire. Mechanical contacts also have to be connected to 1, 3 (channel 2) or 5, 7 Channel 1). A wire-bridge has to be connected between 1, 2 (channel 2) or 5, 6 (channel 1), for switching off the wire-break/short-circuit control or a resistor connection has to be made (in series to the contact 2,7 kω and parallel to the contact 1 kω). The active electrical outputs are connected to terminal 9 (channel 1) and 11 (channel 2). The 14 and 16 are internally bridged to terminal 13 (+24V), The NO/NC-programming of the output relay is possible by means of coding switches in the front plate: Switch position I = NO (factory set), Switch position II = NC if a KAS is connected The s are reversed with connection of an IAS ecause of the PNP output, suitable for switching frequency up to 1 khz. voltage (U ) 2-3 V DC voltage max. current max. Switching capacitiy max. 2 x transistor output pnp 35 V DC 1 ma 3,5 W N-131/2-E-1 N4 diagram No. current (I ) typ. 15 ma voltage max. (U ) 1.5 V DC Short-circuit current max. (I ) 26 ma K inductance max. (L ) [EExia] IIC 45 mh/ II 16 mh capacitance max. (C ) [EExia] IIC 2.41 µf/ II 16.8 µ F NAMUR DIN or EN N-131/2-E-1 N C red/yellow and green All specifications are subject to change without notice. (8/24) housing: IP 3 : IP 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 11

12 51378 N-13/4-2-IL Transmitter Power Supply N-13/4-2-IL - Analogue ma II (1) G [EEx ia] IIC For connection of ATEX certified 2-wire analogue sensors e. g. our KAS-4...IL with ma output N-13/4-2-IL Certificate: TÜV 99 ATEX 1435 Safe galvanic separation between input/output and auxiliary energy (power) At the panel socket Test it is possible to loop in an ammeter Technical data Maximum input voltage U = 28 V Maximum input (power) I = 93 ma ( P = 65 mw) 1 N-13/4-2-IL diagram No. 1 Power supply Power consumption range V AC/ 2-3 V DC 3.1 VA/ 2.2 W /4...2 ma Load 1 Ω Test socket: max. R of the measuring instrumen t R i i = 15 Ω O utput ripple <.5 % N on-linearity <.1 % Temperature coefficient <.1 %/ 1 K S tep response 2.2 ms (1-9 %) Digital bandwidth - 12 A djustability: Zero and Span +/- 5 % Permissible operating temperature Mounting category to IEC 654 Climatic category to DIN 4 4 Galvanic isolation input khz -2 C...+6 C x HSF input-output (output)-power Power on grüne LED Test supply Hilfsenergie (Power) 24 V AC (24 V DC) All specifications are subject to change without notice. (8/24) 12 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

13 POWER SUPPLIES - SERIES EG The EG series control units contain a DC-side short-circuit protected power pack, voltage stabiliser and output relay. The 22 mm small housing is designed for quick mounting on DIN profiles (housing size 7 mm for EG III-...). LED displays are integrated in the front panel for standby and state of output. When a sensor is connected to the unit, it automatically recognises whether the sensor is PNP or NPN output. These control units can be actuated by all 2, 3 and 4-wire sensors with PNP, NPN, NO, NC or antivalent, i. e. our series IAS-1..., IAS-2..., IAS-6..., KAS-7..., KAS-8..., KAS-9..., IS and SW-6. The model EG III-13 can also be connected to one of our KXA-.../ KFA-... or KFX-... sensor systems Details of the parameters to be considered when connecting these systems, are available on request. All specifications are subject to change without notice. (11/24) RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 13

14 522 EGI-13 Power Supply EG I-13 Series 13 - Relay To connect one 2, 3 or 4-wire sensor with NPN or PNP transistor output. When connecting an antivalent sensor (4-wire) the NO or NC output can be connected. With one output relay (1 x changeover) EGI Certificate: Technical Data voltage (U ) 115/23 V AC + 15% Hz current (I ) typ. 2mA rating each relay max.. 1 x potential-free change-over contact 25 V AC/ 6 A EGI drawing voltage (U ) 24 V DC + 2% s current max. (I ) 6 ma s R esidual ripple acc. to DIN max. 2 % pnp or npn C LED green and yello w housing: IP 3 connections: IP 2 All specifications are subject to change without notice. (11/24) 14 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

15 5223 EGII-13 Power Supply EG II-13 Series 13 - Relay Certificate: EGII To connect two 2, 3 or 4-wire sensors with NPN or PNP transistor output (not from our series SW-6). When connecting one antivalent sensor (4-wire) both outputs, NO and NC, can be connected. When connecting two antivalent sensors only one output of each can be connected. With two output relays (1 x changeover and 1 x normally open) Technical Data voltage (U ) 115/23 V AC + 15% Hz current (I ) typ. 4mA rating each relay max.. 1 x potential-free change-over contact / 1 x potenfial-free NO 25 V AC/ 6 A EGII drawing voltage (U ) 24 V DC + 2% s current max. (I ) 6 ma s R esidual ripple acc. to DIN max. 2 % pnp or npn C LED green and yello w All specifications are subject to change without notice. (11/24) housing: IP 3 connections: IP 2 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 15

16 5221 EGI-13-TD Power Supply EG I-13-TD Series 13 - Relay With Time Delay To connect one 2, 3 or 4-wire sensor with NPN or PNP transistor output. When connecting an antivalent sensor (4-wire) the NO or NC output can be connected. With one output relay (1 x changeover) Certificate: EGI-13-TD 5221 This control unit provides an energising or de-energising delay, which is programmable by a switch: A = energising delay, = de-energising delay. Technical Data voltage (U ) 115/23 V AC + 15% Hz current (I ) typ. 2mA rating each relay max.. 1 x potential-free change-over contact 25 V AC/ 6 A EGI-13-TD drawing voltage (U ) 24 V DC + 2% s current max. (I ) 6 ma s R esidual ripple acc. to DIN max. 2 % pnp or npn Version adjustable for C LED green and yello w energising and de-energising delay time t 1 =,1...5 s/ t = 2...6s 2 housing: IP 3 connections: IP 2 All specifications are subject to change without notice. (11/24) 16 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

17 5222 EGI-13-MM Power Supply EG I-13-MM Series 13 - Relay - MIN/MAX-Control To connect two 2 or 3-wire sensors in NO- with NPN or PNP transistor output. When connecting antivalent sensors the NO-output can be connected. Integrated MIN/MAX-Control EGI-13-MM 5222 With one output relay (1 x changeover) Certificate: Technical Data voltage (U ) 115/23 V AC + 15% Hz current (I ) typ. 2mA rating each relay max.. 1 x potential-free change-over contact 25 V AC/ 6 A EGI-13-MM drawing voltage (U ) 24 V DC + 2% s current max. (I ) 6 ma s R esidual ripple acc. to DIN max. 2 % pnp or npn C LED geen or yello w Version min./max. -Contro l housing: IP 3 connections: IP 2 All specifications are subject to change without notice. (11/24) 1 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 17

18 6NA 3 6NA 2 EGIII-13 24/48 VAC EGIII /23 VAC Power Supply EG III Series 13 - Relay To connect three 2, 3 or 4-wire sensors with NPN or PNP transistor output. When connecting an antivalent sensor (4-wire) the NO or NC output can be connected With three output relays EGIII-13 24/48 VAC NA 3 EGIII /23 VAC NA 2 Certificate: Technical Data voltage (U ) 24/48 V AC + 15% Hz 115/23 V AC + 15% Hz current (I ) typ. 4mA rating each relay max.. EGIII-13 24/48 VAC 3 x potential-free change-over contact s 25 V AC/ 6 A EGIII /23 VAC NA 3 NA 2 drawing voltage (U ) 24 V DC + 2% s current max. (I ) 1 ma s R esidual ripple acc. to DIN max. 2 % pnp or npn C LED green and yello w housing: IP 3 connections: IP 2 L1 23V/48V L1 115V/24V All specifications are subject to change without notice. (11/24) 18 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de

19 TYPE SELECTION IN ARTICLE NUMER ORDER Description Page N-13/4-2-IL EGI EGI-13-TD EGI-13-MM EGII N1 N-131/2-1 8 N2 N-131/2-2 9 N3 N-131/2-1 1 N4 N-131/2-E-1 11 N5 N-131/1-1 5 N6 N-131/1-2 6 N7 N-131/1-1 7 NA 2 EGIII /23 VAC 18 NA 3 EGIII-13 24/48 VAC 18 TYPE SELECTION IN TYPE DESCRIPTION ORDER All specifications are subject to change without notice. (11/24) Description Page EGI EGI-13-MM EGI-13-TD EGII EGIII /23 VAC NA 2 18 EGIII-13 24/48 VAC NA 3 18 N-13/4-2-IL N-131/1-1 N5 5 N-131/1-2 N6 6 N-131/1-1 N7 7 N-131/2-1 N1 8 N-131/2-2 N2 9 N-131/2-1 N3 1 N-131/2-E-1 N4 11 RECHNER Industrie-Elektronik GmbH Gaußstraße 8-1 D Lampertheim Tel. +49 () Fax +49 () info@rechner-sensors.de 19

20 SENSORS FOR INDUSTRIAL AUTOMATION CAPACITIVE INDUCTIVE MAGNETORESISTIVE CALORIMETRIC ASK for further catalogues: CAPACITIVE SENSORS KAS CAPACITIVE SENSORS KXS INDUCTIVE SENSORS MAGNETORESISTIVE SENSORS CAPACITIVE LEVEL MEASURING SYSTEMS FLOW SENSORS ATEX CERTIFIED PRODUCTS Your Representative INDUSTRIE-ELEKTRONIK GmbH Gaußstraße Lampertheim Germany Tel. +49 () Fax Intl. +49 () info@rechner-sensors.de

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services

More information

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid.

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid. SHORTFORM CATALOGUE Registration No.: 1327-01 Testing laboratory accredited according to DIN EN 001 Reg.-No. DAT-P-08/9-00 For all transactions, the newest version of the General Conditions of Sale and

More information

www.rechner-sensors.com CATALOGUE SerieS 26 - Model range 700/800 Capacitive level sensors for liquids or pastes, for example: Water Oil Ketchup 2 Registration No.: 1327-01 For all transactions, the newest

More information

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to

SHORTFORM CATALOGUE. DIN EN Reg.-No. DAT-P-048/ Testing laboratory accredited according to SHORTFORM CATALOGUE Registration No.: 1327-01 Testing laboratory accredited according to DIN EN 45001 Reg.-No. DAT-P-048/95-00 For all transactions, the newest version of the General Conditions of Sale

More information

www.rechner-sensors.com CATALOGUE CAPACITIVE LEVEL MEASURING SYSTEMS 2 Registration-No: 1327-01 Testing laboratory accredited according to DIN EN ISO / IEC 17025 Reg.-No. DGA-PL-048/95-03 For all transactions

More information

www.rechner-sensors.com Catalogue MAGNETO- RESISTIVE SENSORS Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services

More information

Operating Instructions

Operating Instructions Operating Instructions FLUDEX-EOC system A. Friedr. Flender AG 46393 Bocholt Tel. 02871/92-0 Telefax 02871/92-2596 www.flender.com Contents 1. Application 3 2. Operation 3 3. Fitting 4 3.1 Fitting transmitter

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

Assembly. Front view. Power Rail

Assembly. Front view. Power Rail Thermometer Resistance Repeater Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) RTD/resistance input Resistance output Accuracy 0.1 % Front view Removable terminals blue Function

More information

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier

Certified according to DIN EN ISO Technical Datasheet EWS. Intrinsically Safe Supply and Separation Amplifier Certified according to DIN EN ISO 9001 Technical Datasheet EWS Intrinsically Safe Supply and Separation Amplifier Description... 3 Technical Data... 3 Options... 7 Notes... 7 Connections... 8 Ordering

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC

More information

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition solated switch amplifier Output: relay Connection Control circuit EEx ia C 24 V DC nominal supply voltage Reversible mode of operation Lead monitoring (short-circuit LK and interruption LB) with LED indicator

More information

Magneto-resistive sensors

Magneto-resistive sensors Magneto-resistive sensors 2018 RoHS Compliant For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services of the Electrical Industry ZVEI shall apply,

More information

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0) Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)

More information

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194 DIN Rail Devices Description DIN rail devices serve as low cost signal conditioning modules between the field device and the control system. The new enclosures mounted on the 35 mm standard rail are equipped

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

Temperature Transmitter itemp RTD DIN rail TMT 127

Temperature Transmitter itemp RTD DIN rail TMT 127 Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed

More information

Temperature Measuring Amplifier IM34-11Ex-Ci IM34-12Ex-CRi 1-channel

Temperature Measuring Amplifier IM34-11Ex-Ci IM34-12Ex-CRi 1-channel Error Power Switching status 10 11 12 7 8 9 1 10 11 12 7 8 9 Temperature Measuring mplifier IM4-11Ex-Ci IM4-12Ex-CRi 1-channel PC-Connect PC-Connect IM4-12Ex-CRi IM4-11Ex-Ci 4 5 6 1 2 4 5 6 1 2 1-channel

More information

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Assembly. Front view. HiC2441. SL2 1b. Termination Board SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

Temperature Measuring Amplifier IM34-11Ex-i IM34-12Ex-Ri 1-channel

Temperature Measuring Amplifier IM34-11Ex-i IM34-12Ex-Ri 1-channel Error Power Switching status 10 11 12 7 8 9 1 10 11 12 7 8 9 Temperature Measuring mplifier IM4-11Ex-i IM4-12Ex-Ri 1-channel IM4-12Ex-Ri IM4-11Ex-i 4 5 6 1 2 4 5 6 1 2 1-channel temperature measuring amplifier

More information

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

TR 104, TR 104-Ex Rail mounted Temperature Transmitters Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net

More information

RMA42. Technical Information

RMA42. Technical Information Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically

More information

SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC) Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

SINEAX B 811 Power Pack with additional Functions

SINEAX B 811 Power Pack with additional Functions SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers

More information

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter) JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

PR product range - links to order details and block diagrams

PR product range - links to order details and block diagrams PR product range links to order details and block diagrams 2202 2204 2220 2222 2223 2224 2229 2231 2237 2238 2240 2241 2255 2261 2271 2273 2279 2281 2284 2285 2286 2288 2289 2914 3532 4114 4116 4131 5102

More information

Operating Instructions

Operating Instructions Level and Pressure Operating Instructions VEGATOR 620, 621, 622 max. 0 10 min. 0 10 on VEGATOR 622! 6 7 8 9 10 11 12 13 14 in out Contents Contents Safety information... 2 Note Ex area... 2 1 Product description

More information

Rail mounted Temperature Transmitter TH102/TH102-Ex

Rail mounted Temperature Transmitter TH102/TH102-Ex Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input

More information

Electrical Alarm Contacts

Electrical Alarm Contacts Accessories Electrical Alarm Contacts T Model 821, Magnetic Snap-Action Contacts T Model 831, Inductive Alarm Sensors T Model 830 E, Electronic Contacts WIKA Data Sheet AC 08.01 Applications T Control

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Temperature head transmitter itemp PCP TMT 181

Temperature head transmitter itemp PCP TMT 181 Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Temperature Transmitters TMT 136, TMT 137

Temperature Transmitters TMT 136, TMT 137 Technical Information TI 066R/09/en Part No. 51000855 Temperature Transmitters TMT 136, TMT 137 For Pt100 Resistance Thermometers 2-wire head transmitter Standard- and instrinsically safe versions Head

More information

Temperature transmitter itemp RTD DIN rail TMT 127

Temperature transmitter itemp RTD DIN rail TMT 127 Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 5 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC 6508/EC

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 WIKA data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Assembly. Front view. Switch Power Rail

Assembly. Front view. Switch Power Rail Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency

More information

Level Limit Switch nivotester FTL 370, FTL 372

Level Limit Switch nivotester FTL 370, FTL 372 Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational

More information

PRetrans Table of contents

PRetrans Table of contents HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting

More information

Temperature head transmitter itemp TC TMT 188

Temperature head transmitter itemp TC TMT 188 Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC

More information

Level Limit Switch nivotester FTL 325 P

Level Limit Switch nivotester FTL 325 P Technical Information TI 350F/24/ae Level Limit Switch nivotester FTL 325 P With intrinsically safe signal circuit for connection to the Liquiphant and Soliphant measuring sensor Application Level limit

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Technical Information RMA42

Technical Information RMA42 TI00150R/09/EN/05.16 71315973 Products Solutions Services Technical Information RMA42 Process transmitter with control unit Digital process transmitter for monitoring and visualizing analog measured values

More information

Trip amplifier, 1 channel

Trip amplifier, 1 channel Trip amplifier, channel Features I II III + + P I out I U out 4 Relay overrange Relay overrange Relay overrange ç 4...0 ma IM4-4-SRi: è 0...0 ma IV + + + > 50 kw 5 6 7 8 9»8 V < 5 ma 50 W Pwr GN/RD 4 5

More information

Electrical Alarm Contacts

Electrical Alarm Contacts Accessories Electrical Alarm Contacts Model 82, Magnetic Snap-Action Contact Model 83, Inductive Alarm Contact Model 830 E, Electronic Contact WIKA Data Sheet AC 08.0 Applications Control and regulation

More information

Isolators A3/1.

Isolators A3/1. > Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN

Electronic alarm signalling unit TES 20. for temperature and standard signals ENA EN Electronic alarm signalling unit TES 20 ENA117.01 EN for temperature and standard signals Universal alarm signalling unit (constructional width 4 T) for Temperature (temperature monitor) with Pt 100 IEC

More information

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages

More information

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461 October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

Rotational speed controller

Rotational speed controller Model number Features Rotational speed monitoring up to khz pre-select value with relay output and LED indicator Multi-range power pack -, -, -wire and NAMUR sensors as well as rotary encoder connectable

More information

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1

Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 Force Load pin With thin-film technology up to 70 kn Models F5301, F53C1, F53S1 WIKA data sheet FO 51.18 Applications Crane systems and hoists Industrial weighing technology Machine building and plant

More information

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail

Assembly. Front view. DIP switch. LED yellow: Relay output I. LED yellow: Relay output II. Potentiometer Hysteresis relay I Power Rail Current/Voltage Trip Value Features Assembly 1-channel signal conditioner 24 V DC supply (Power Rail) Current and voltage input 2 relay outputs Programmable high/low alarm Configurable via DIP switches

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

Safety Instructions Nivotester FTC625, FTC325

Safety Instructions Nivotester FTC625, FTC325 XA01351F-A/00/EN/01.14 71273077 Products Solutions Services Safety Instructions FTC625, FTC325 [Ex ia Ga] IIC/IIB TÜV 13.0903 X Segurança TÜV INMETRO OCP 0004 Document: XA01351F-A Safety instructions for

More information

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference

More information

0 2 1 â Ó. itemp HART TMT182. Technical Information

0 2 1 â Ó. itemp HART TMT182. Technical Information Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for

More information

itemp PA TMT184 Technical information

itemp PA TMT184 Technical information Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and

More information

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1

Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Force Shear beam With thin-film technology from 2 kn Models F3301, F33C1, F33S1 Rated force From 0...2 kn Applications Industrial weighing technology Machine building and plant construction, manufacturing

More information

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.

More information

Electronic Thermostat TE-1 Version according to EN

Electronic Thermostat TE-1 Version according to EN JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 3639 Fulda, Germany Postal address: 3635 Fulda, Germany Phone: +49 661 63- Fax: +49 661 63-67 e-mail: mail@jumo.net Internet: www.jumo.net JUMO

More information

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier

Photo-electric Amplifier ISG-A123 1-channel automatic amplifier Photo-electric Amplifier -channel automatic amplifier Amplifier with modulated infrared light Range up to 25 m (82 ft) Automatic Level Control (ALC) according to assembly distance and direction Test function

More information

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en

electronics Data Sheet Industrial Amplifier Special features Dimensions (in mm; 1 mm= inches) B en C l i p electronics Industrial Amplifier Data Sheet Special features Amplifier and additional units for strain gauge full bridges and inductive half and full bridges Modules for mounting onto support rails

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier Technical Information Nivotester FTR325 1-channel switch amplifier for the Soliwave M microwave barrier Area of application The Nivotester FTR325 is suitable as a 1-channel switch amplifier for the Soliwave

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information