1 Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2, 3, 4 wire circuit) Thermocouples Resistance remote signalling unit ( Ω) Voltages, mv ( mv) 2 wire technique, HART signal 1 or 2 independent channels Electrical isolation (I/O) Measured error 0.1 K Customer-specific linearization 32 tie points Continuous sensor and self-monitoring Parameter saved permanently in EEPROM Monitoring of data integrety every 10 s Wire break monitoring in acc. with NAMUR NE 89 Substitution strategy in case of error (NE 43) Approvals for explosion protection Intrinsically safe II 2 (1) G EEx [ia] ib IIC T6, mount in zone 1 II 3 G EEx n A II T6, mount in zone 2 functionality (absolute, differential, average value) EMC acc. to EN and NE Parameterization Device Management Tool: SV401 (SMART VISION) Hand held terminals: 691HT, STT04, HHT275 CoMeter (HART configurator/lc display) 5 years warranty Excellent long term stability Temperature linear output signal Enhanced self diagnostics
2 10/-8.54 EN Technical data signal (temperature linear) Residual ripple (peak-to-peak) < 0.3 % Current consumption < 3.6 ma Maximum output current.6 ma Parameterizable current error signal Underranging 3.6 ma Overranging ma Default value ma Damping t 63 = s Resistance Resistance thermometer (IEC 751, JIS, SAMA) n Pt 100/Ni 100 to Pt 1000/Ni 1000; Cu (n = 0.1, 0.2, 0.5, 1, 1.2, 2, ) Min. measuring span 15 K/50 K Resistance Ω/ Ω Min. measuring span 5 Ω/50 Ω Maximum line resistance (R w ) per core 2, 3, 4 wire 7.5 Ω, 10 Ω, 50 Ω Measuring current 300 µa Sensor short-circuit < 5 Ω (for RTD) Sensor break (temperature/resistance measurement 2, 3, 4 wire) Measuring range Ω > 530 Ω Measuring range Ω > 5.3 kω Sensor wire break monitoring in accordance with NAMUR NE 89 Sensor wire break detection 3 wire resistance measurement > 35 Ω 4 wire resistance measurement > 3.7 kω filter 50/60 Hz Thermocouples Types B, E, J, K, L, N, R, S, T, U Voltages -5 mv mv -5 mv mv Minimum measuring span 2 mv/50 mv Sensor wire break monitoring in accordance with NAMUR NE 89 Pulsed with 1 µa outside of the measuring interval Monitoring disconnectible Thermocouple measurement > 5 kω Voltage measurement > 5 kω filter 50/60 Hz Internal reference junction Pt 100, via software switchable (no jumper necessary) Standard IEC DIN IEC 751; JIS; SAMA 1) 2, 3 and 4 wire DIN ) 2, 3 and 4 wire element Measuring range Min. measuring span Sensor Thermocouple type B Thermocouple type E Thermocouple type J Thermocouple type K Thermocouple type R Thermocouple type S Thermocouple type T Thermocouple type N Thermocouple type L Thermocouple type U Resistance thermometer Pt 100 Resistance thermometer Pt 1000 Resistance thermometer Ni 100 Resistance thermometer Ni C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) C ( F) Resistance Ω Ω/ Ω 5 Ω/50 Ω Voltage mv 5 mv mv 5 mv mv 2 mv 50 mv 5 C (4 F) 30 C ( 54 F) 37 C ( 67 F) 54 C ( 98 F) 171 C (308 F) 193 C (348 F) 50 C ( 90 F) 60 C (108 F) 36 C ( 65 F) 40 C ( 72 F) 15 C ( 28 F) 50 C ( 90 F) 8 C ( 15 F) 15 C ( 28 F) 1) IEC 751 a = , JIS a = , SAMA a = ) Edison Curve No. 7 2
3 10/-8.54 EN Power supply (poling protected) Supply voltage Non-Ex-application U s = V DC For Ex-Application, max. U i = V DC 2 wire methode: power supply wires = signal wires Influence of supply voltage < 0.05 %/10 V maximum residual ripple 1 % U S (< 500 Hz) Maximum load Maximum permissible load R 910 Ω Z-20160_1 (HC) R( kω ) General characteristics signal refreshment rate Pt s ( signal change < 0.25 K/s) Thermocouples 0.2 s ( signal change < 2.5 K/s) Vibration resistance Vibration in operation 2g acc. to DIN IEC 68T.2-6 Resistance to shock acc. to DIN IEC 68T.2-27 Electrical isolation (I/O) 1.5 kv AC (60 s) Long-term stability 0.1 % p.a. Environment conditions Ambient temperature range C Transport and storage temperature C Relative humidity < 100 % Condensation Permitted 8,5 ( U smax U smin ) = ,4 Operation range V DC Power supply Us 30 Mechanical construction Dimensions Confer dimensional drawing Weight 250 g Housing material Polyamid Light grey (RAL 9002) Type of protection IP 20 (DIN 40050) Class of protection 2 (IEC 348) Class of combustibility V2 to V0 acc. to UL 94 Electrical connection Terminals, pluggable 2.5 mm 2, screw terminals Characteristics at rated conditions According to IEC 770 (related to 25 C) 1) Digital measured error Pt 100 ± 0.1 K Thermocouples ± 20 µv Linear resistance 500 Ω/5000 Ω ± 40 mω/200 mω Linear voltage 0 mv/00 mv ± 20 µv/50 µv D/A measured error ± 0.05 % of measuring span Additional influence of the internal reference junction Pt 100 DIN IEC 751 Kl. B Influences Influence of ambient temperature Pt 100/resistance measurement 2) < ( 0.05 % Thermocouple/mV 3) < ( 0.05 % ME ( Ω ) % ) 10 K MS ( Ω ) ME ( mv ) MS ( mv ) 0.01 % K 100 % ) 10 K MS ( K) Percentage related to measuring span MS = ME MA MA = lower range value, ME = upper range value 1) Percentage related to set measuring span Specified values corresponds to 3 σ (Gaussian normal distribution) 2) Pt 100 ( C): Influence of ambient temperature < (0.05 % %)/10 K = %/10 K 3) Type K ( C): Influence of ambient temperature < (0.05 % % %)/10 K = %/10 K 3
4 10/-8.54 EN Explosion protection Intrinsically safe Zone 1 Marking II 2 (1) G EEx [ia] ib IIC T6 EC-Type-Examination certificate PTB 99 ATEX 29 X Temperature class T6/T5/T4 50 C/65 C/85 C Supply circuit [ib] [ia] Max. voltage U i = 29.4 V U o = 5.6 V Short-circuit current I i = 0 ma I o = 1.5 ma 4) Max. power P i = 0.8 W P o = 20 mw Internal inductance L i = 0 µh L o = 1 mh Internal capacitance C i = 15 nf C o = 1.55 µf Zone 2 Marking II 3 G EEx n A II T6 Conformity statement PTB 99 ATEX 16 X Temperature class T6/T5/T4 50 C/65 C/85 C Electromagnetic compatibility (EMC) Pt 100: measuring range C, span 100 K Type of test Degree Influence IEC Burst to signal/ 3 kv < 0.1 % data lines Static discharge Contact plate (indirect) Terminals for supply 5) Terminals for sensors 5) 8 kv 6 kv 4 kv no influence no influence no influence Radiated field MHz...1 GHz 10 V/m < 1.0 % Coupling 150 khz - 80 MHz 10 V < 1.0 % According to NAMUR NE recommendation. In case of an input signal change > 0.25 K/s for Pt100 or > 2.5 K/s for thermocouples a measured value plausibility check is performed. 5) Air discharge (at 1 mm distance) 4) See 1. supplement PTB 99 ATEX 29 X 4
5 10/-8.54 EN Communication/parameterization Hand held terminal HHT 691HT, STT04, HHT275 CoMeter Hart conigurator and LC display Device Management Tool SV401 (SMART VISION) Parameter Sensor type, error signalling, measuring range, general characteristics (i. e. TAG number), damping, signal simulation of output Software interface AMS, Cornerstone CoMeter ABB TH102-Ex PTB 99 ATEX 29 X II 2 G EEx [ia] ib IIC T6 TA<=50 C Ex Elektr. Daten siehe EG-Baumusterprüfbesch. Kanal 1: PT 100-3L C Kanal 2: PT 100-3L C Line resistance GND (250 Ω min.)* (optional) Processinterface or Isolators Controller Recorders 1) or 691HT, STT04, HHT275 FSK Modem *if necessary Z-20162e 5
6 10/-8.54 EN Connection diagram 31 + Us= 8,5...30V DC 32 - Microprocessor Channel 1 Reference- Junction + - VDCV V VDC 41 + Us= 8,5...30V DC 42 - Microprocessor Channel 2 Reference- Junction + - VDCV V VDC a) b) c) d) e) f) g) h) i) For the 1 channel version view wiring diagram of channel 1 Z a) Resistance thermometer, 2 wire circuit b) Resistance thermometer, 3 wire circuit c) Resistance thermometer, 4 wire circuit d) Double resistance thermometer, 2 wire circuit (average value or differential temperature measurement) e) Potentiometer input, 4 wire circuit f) Thermocouple g) Double thermocouple (average value or differential temperature measurement) h) Voltage measurement i) Double voltage measurement (average value or differential temperature measurement) Dimensional diagram (Dimensions in mm) 99 ABB TH102-Ex PTB 99 ATEX 29 X II 2 G EEx [ia] ib IIC T6 TA<=50 C Ex Elektr. Daten siehe EG-Baumusterprüfbesch. Kanal 1: PT 100-3L C Kanal 2: PT 100-3L C Us= 8,5...30V DC Us= 8,5...30V DC Microprocessor Channel 1 Reference- Junction Microprocessor Channel 2 Reference- Junction a) b) c) d) e) VDCV V VDC VDCV V VDC f) g) h) i) 35,5 4,5 Z
7 10/-8.54 EN Ordering information Catalog No. EUR Deliv. time TH102/TH102-Ex V517- ex stock Without Explosion protection: TH102 1-channel 1 264,60 * TH102 2-channel 3 496,70 * With Explosion protection Zone 1 TH102-Ex 1-channel ATEX: II 2 (1) G EEx [ia]ib IIC T ,90 * TH102-Ex 2-channel ATEX: II 2 (1) G EEx [ia]ib IIC T ,30 * Zone 2 / type N TH102-Ex N 1-channel ATEX: II 3 G EEx n A II T6 N 291,90 * TH102-Ex N 2-channel ATEX: II 3 G EEx n A II T6 M 552,30 * Programming 1-channel Factory standard parameter 0 - Pt 100, C, 4 wire circut, damping off, direct action characteristic overranging at sensor or device error (.5 ma) Customer-specific parameter setting, one-channel version 1,50 * 2-channel Factory standard parameter 2 - Pt 100, C, 4 wire circuit, damping off, direct action characteristic overranging at sensor or device error (.5 ma) Customer-specific parameter setting, two-channel version 3 32,20 * Calibration certificates without 0-1-channel 2 point 1 75,60 * 1-channel 9 point 2 107,10 * 2-channels 2 point A 107,10 * 2-channels 9 point B 160,70 * Accessories Catalog No. EUR Deliv. time ABB FSK modem [EEx ib] IIC (parameter setting in the installation) see Data Sheet 10/ EN Device Management Tool SV401 (SMART VISION) see Data Sheet 10/ EN TH02/-102/-202 driver for AMS software 1.4 (Rosemount) 1) ,10 * 1) already integrated in AMS software version 5.0 or higher Notice: For a lokal programming on the desk can used as Hardware the universal FSK Programming-Set (without Parasoft). (see Data Sheet 10/ EN ordering information) 7
8 The Industrial IT wordmark and all mentioned product names in the form XXXXXX IT are registered or pending trademarks of ABB. ABB has Sales & Customer Support expertise in over 100 countries worldwide. The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in the Fed. Rep. of Germany (10.02) ABB /-8.54 EN Rev. A ABB Ltd. Salterbeck Trading Estate Workington, Cumbria CA 5DS UK Tel: +44 (0) Fax: +44 (0) ABB Inc. 5 E. County Line Road Warminster, PA USA Tel: Fax: ABB Automation Products GmbH Borsigstr Alzenau Germany Tel: Fax:
Rail mounted Temperature Transmitter TH102/TH102-Ex
Data Sheet 10/-8.54 EN Rail mounted Temperature Transmitter TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Input Resistance thermometer (2, 3, 4 wire circuit) Thermocouples
More informationFieldIT Temperature Transmitter, head mounted TH02/TH02-Ex
Data Sheet 0/-8.9 EN Level 0: Information FieldIT Temperature Transmitter, head mounted TH0/TH0-Ex HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Input Resistance thermometer (,, wire
More informationFieldIT Temperature Transmitter, field mounted TH202/TH202-Ex
Data Sheet 0/-8.6 EN Level 0: Information FieldIT Temperature Transmitter, field mounted TH0/TH0-Ex HART programmable, Pt 00 (RTD), thermocouples, electrical isolation Input Resistance thermometer (,,
More informationTR 104, TR 104-Ex Rail mounted Temperature Transmitters
Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationContrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN
Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 e-mail: mail@jumo.net Internet: www.jumo.net
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET TTR200 Rail-mount temperature transmitter 2 TTR200 RAIL-MOUNT TEMPERATURE TRANSMITTER DS/TTR200-EN REV. D Measurement made easy Temperature transmitter
More informationTS05 Input Functional description Output Deviation 0.15 % Electrical isolation Programming of the measuring range via push-button
TS05 Headmounted temperature transmitter, programmable via pushbutton, thermocouples Input Thermocouples; K, J, T / R, S, B / J, F, E Output 2wire technique 4...20 ma Temperaturelinear Deviation 0.15 %
More informationJUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationTemperature Measurement
Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationDigital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting
Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03
More information0 2 1 â Ó. itemp HART TMT182. Technical Information
Technical Information itemp HART TMT182 Temperature head transmitter Head transmitter for resistance thermometers (RTD), thermocouples (TC), resistance and voltage transmitters (mv), HART -protocol, for
More informationIndicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN
Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm
More informationTTH200 Head-mount temperature transmitter
Change from one to two columns Data Sheet DS/TTH200-EN Rev. B TTH200 Head-mount temperature transmitter Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationTemperature transmitter itemp PCP DIN rail TMT 121
Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. TTF200 Field-mount temperature transmitter
ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET TTF200 Field-mount temperature transmitter 2 TTF200 FIELD-MOUNT TEMPERATURE TRANSMITTER DS/TTF200-EN REV. B Measurement made easy Temperature transmitter
More informationSITRANS T measuring instruments for temperature
SITRANS T measuring instruments for temperature /2 Product overview /6 Transmitter for mounting in sensor head /6 SITRANS TH100, two-wire system (Pt100) /9 SITRANS TH200, two-wire system universal /15
More informationJUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationC330 / C330X PC-Programmable Universal, 2-wire Transmitter
C330 / C330X PC-Programmable Universal, 2-wire Transmitter The IPAQ C330 transmitter is a universal, isolated, temperature transmitter with additional voltage and resistance input. Its robust design and
More informationC520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters
C520 / C520X /C520S / C520XS HART Compatible, Universal, Dual-input 2-wire Transmitters The 520 transmitters are universal, isolated, dual-input temperature transmitters with additional voltage and resistance
More informationSINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs
SINEAX V 6 for rail mounting in housing P/7 or P/7 St 00 II () GD Application SINEAX V 6 (Figs. and ) is designed for measuring temperature in combination with thermocouples or resistance thermometers.
More informationTemperature Measurement
Temperature Measurement SITANS T00 Overview Application SITANS T00 transmitters can be used in all industrial sectors. Their compact design enables simple mounting on standard DIN rails on-site in protective
More informationUniversal Intelligent 2-wire DIN Rail Transmitters
Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationitemp HART DIN rail TMT112
Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application
More informationContents. TS 11, TS 11-Ex. Intelligent transmitter for temperature sensor head mounting
TS 11, TS 11-Ex Intelligent transmitter for temperature sensor head mounting Contents Page Operating Manual 42/11-44 EN Rev. 2.0 Short description... 4 Installation and Commissioning Scope of delivery...
More informationOperator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique
Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter
More informationUniversal Intelligent 2-wire In-head Transmitters
Universal Intelligent 2-wire In-head Transmitters Actual size IPAQ-H is a universal and intelligent 2-wire In-head transmitter for temperature and other measurement applications. IPAQ-HX is the Intrinsic
More informationSITRANS T measuring instruments for temperature
Overview Our field devices for heavy industrial use HART, Universal 4 to 20 ma, universal Field indicator for 4 to 20 ma signals The temperature transmitter SITRANS TF works where others feel uncomfortable.
More informationAssembly. Front view. Parametrization interface. Power Bus
Temperature Converter Features Assembly 1-channel signal conditioner 24 V DC supply Thermocouple, RTD, potentiometer or mv input Input for PTC thermistor Current and voltage output Line fault (LFD) and
More informationTemperature Measurement
Siemens AG 015 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,
More informationHART Compatible Intelligent 2-wire In-head Transmitters
HART Compatible Intelligent 2-wire In-head Transmitters Actual size MESO-H is a Smart and universal 2-wire Inhead transmitter for temperature and other measurement applications. MESO-HX is the Intrinsic
More informationTemperature Transmitter itemp RTD DIN rail TMT 127
Technical Information TI 095R/09/en No. 51004790 Temperature Transmitter itemp RTD DIN rail TMT 127 Temperature Transmitter for Pt100 Resistance Thermometer Application Temperature transmitter with fixed
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationPROGRAMMABLE FIELD TEMPERATURE TRANSMITTER
Configuration Code TM01 Series 642 Programmable HART Field Temperature The Series 642 programmable HART field temperature transmitter is a 2-wire unit with analog output. It includes input for RTDs; resistance
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationTemperature Measurement Transmitters for mounting in sensor head
Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationTemperature transmitter itemp RTD DIN rail TMT 127
Technical information TI 095R/24/ae Nr. 510 06165 Temperature transmitter itemp RTD DIN rail TMT 127 Pt100 transmitter for an economical, high accuracy temperature monitoring. Fixed range measurement,
More informationDigital Indicator DS 96/48 PK
Data Sheet 10/33-2.1-EN Digital Indicator DS 9/48 P Digital Indicator DS 9/48 PK Inputs Direct current, direct voltage Thermocouple Resistance thermometer Programmable via front keys or PC software Limit
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationModel 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet
Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard
More informationTemperature Transmitters TMT 136, TMT 137
Technical Information TI 066R/09/en Part No. 51000855 Temperature Transmitters TMT 136, TMT 137 For Pt100 Resistance Thermometers 2-wire head transmitter Standard- and instrinsically safe versions Head
More informationPositioner with HART Communication Type 3780
Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels
More informationTZIF 4. Current-to-Pulse Converter 10/ EN
TZIF 4 Current-to-Pulse Converter Conversion of direct current or voltage signals into a proportional pulse frequency Integration and average value formation of analog signals for quantity counting/remote
More informationTemperature Measurement
Siemens AG 017 / Product overview Transmitters for mounting in sensor head /4 SITRANS TH100 two-wire system (Pt100) /8 SITRANS TH00 two-wire system universal /15 SITRANS TH00 two-wire system universal,
More informationMACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:
Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer
More informationitemp PA TMT184 Technical information
Technical information itemp PA TMT184 Temperature head transmitter with PROFIBUS-PA interface. Supply and digital communication using PROFIBUS-PA, for installation in a Form B sensor head. Features and
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationHART Compatible Intelligent 2-wire DIN Rail Transmitters
HART Compatible Intelligent 2-wire DIN Rail Transmitters MESO-L is a Smart and universal 2-wire DIN Rail transmitter for temperature and other measurement applications. MESO-LX is the Intrinsic Safe version
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Basic temperature transmitter offers a cost-effective solution for temperature monitoring points transmitter design provides flexible
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationDigital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version
Electrical temperature measurement Digital temperature transmitter with HART protocol Model T32.1S, head mounting version Model T32.3S, rail mounting version WIKA data sheet TE 32.04 Applications Process
More informationTemperature head transmitter itemp PCP TMT 181
Technical information TI 070R/09/en Mat.-Nr.: 510 01110 Temperature head transmitter itemp PCP TMT 181 Universal head transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More informationâ itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring
Technical information itemp Pt100 TMT127 Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring Application Temperature transmitter with fixed measuring range for converting a
More informationSITRANS T measuring instruments for temperature
SITRANS T measuring instruments for temperature /2 Product overview / SITRANS T transmitters for mounting in sensor head / SITRANS TK PA, with PROFIBUS connection /8 SITRANS TH100, two-wire system (Pt100)
More informationâ Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)
Technical information itemp TC TMT128 DIN rail mounted Temperature Transmitter for Thermocouples (TC) Application Temperature transmitter with fixed measuring ranges for converting TC input signals into
More informationTemperature measurement TMD 832 head transmitter
Technical information TI 062R/09/en Mat.-Nr. 510 00782 Temperature measurement TMD 832 head transmitter SMART head transmitter with HART protocol for RTD, Thermocouple and mv input signals Applications
More informationMultifunction Intelligent 4-wire Isolated Signal Conditioner
Multifunction Intelligent 4-wire Isolated Signal Conditioner IPAQ-4L is a fully universal and intelligent 4- wire (mains powered) transmitter for temperature measurement and signal conditioning applications.
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationTemperature Transmitters - DIN Rail Mounted
XTD Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationOPTITEMP TT 10 C/R Technical Datasheet
OPTITEMP TT 10 C/R Technical Datasheet Analogue 2-wire temperature transmitter Temperature linear 4...20 ma output Rangeable with solder pads and potentiometers Easy wiring through large center hole The
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and
More informationDigital Indicator DS 96/24
Data Sheet 10/33-2.11-EN Digital Indicator DS 96/24 This indicator is suitable for measuring direct voltage or direct current. By using potentiometers, the digital display can be assigned to any input
More informationTemperature Transmitters - Head Mounted
XTH Features - Non-programmable Models Sensor Types: Models for thermocouple Types J, K, or T Models for RTD Type Pt100 3-wire Select from a variety of pre-configured measuring ranges Internal cold junction
More informationSINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar
For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationDigital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version
Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building
More informationTemperature head transmitter itemp TC TMT 188
Technical information TI 077R/24/ae No.: 510 06145 Temperature head transmitter itemp TC TMT 188 Universal head transmitter for thermocouples for an economical, high accuracy temperature monitoring. Fixed
More informationSINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex
for electrically insulating, amplifying and converting DC signals, also designed for FSK 1 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1) is to electrically insulate
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and
More informationPRetrans Table of contents
HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting
More informationRMA42. Technical Information
Technical Information RMA42 Process transmitter with control unit Digital process transmitter for mounting on a top-hat rail for monitoring and visualizing analog measured values Application Plant and
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationSTT 3000 Smart Temperature Transmitter Series STT170 Specifications
STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable
More informationHART field temperature transmitter Models TIF50, TIF52, TIF62
Electrical temperature measurement HART field temperature transmitter Models TIF50, TIF52, TIF62 WIKA data sheet TE 62.01 Applications Plant construction Process engineering General industrial applications
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationSINEAX / EURAX 2I1 Passive DC signal isolator
SINEAX / EURAX I without power supply 0 II () G resp. II () G Application The DC signal isolator SINEAX/EURAX I (Figs. and ) serve to isolate load-independent DC current signals. It suppressed noise voltages
More information