SINEAX B 811 Power Pack with additional Functions

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "SINEAX B 811 Power Pack with additional Functions"

Transcription

1 SINEA B 8 for intelligent and conventional s, in housing S7 for rail and wall mounting 002 II () G Application The power supply unit SINEA B 8 (Figure ) provides the DC power supply for s and transfers the measured variable unchanged to the electrically insulated output. Conversion to a different signal range such as 0 to 5 ma or to 5 V (signal converter) is also possible. Some versions of the SINEA B 8 are designed for communication. They are used in conjunction with intelligent s which are capable of dialogue and operation according to the principle and the HART or user-specific protocol. The series also includes intrinsically safe versions [EEx ia] IIC with an intrinsically safe measurement/supply circuit. These operate in conjunction with intrinsically safe s located in explosion hazard areas. Provision is made for monitoring the measurement/supply circuit to detect short and open-circuits. Either of these faults is signalled by the fault signalling relay and the red LED. The output signals A and A2 can be set on the DIP switches to have a linear increasing or decreasing response. The instrument fulfils all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 6 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 900. Production QA is also certified according to guideline 94/9/EG. Fig.. SINEA B 8 in housing S7. Output can be switched between 0 to 20 ma and 4 to 20 ma / Universal matching to suit downstream device Green power on LED Compact and narrow Technical data Features / Benefits Designed for communication, hand-held terminal connected to separate terminals. This facilitates operation in conjunction with an intelligent designed for and with a HART or user-specific protocol Electrically insulated between input circuit, output and power supply / Fulfils IEC 00 resp. EN 6 00 part 2 AC/DC power supply / Universal Intrinsically safe version [EEx ia] IIC available (see Table 5 Explosion protection data ) Measurement/supply circuit monitored for open and short-circuits / Faults signalled by red LED, signalling relay and/or device failure signal (MSK) Signal range I E Supply voltage (at I E = 20 ma) 4 to 20 ma DC 24 V ± 7% with standard (non-ex) version, not designed for communications protocol 24 V ± 7% with standard (non-ex) version, designed for communication > 6.9 V with Ex versions not designed for communications protocol > 6.4 V with Ex versions designed for communication = Frequency Shift Keying Camille Bauer Data sheet B8- Le 07.07

2 SINEA B8 Current limiter Max. line resistance Electronic At I E > 30 ma, is switched to 0 V for approx. s. is then automatically readjusted to its set-point The maximum line resistance R Line permissible between the and the supply unit depends on the voltage difference U M R Line max. = U M 20 ma = Supply voltage for U M = Min. operating voltage of the If the load of the burden across output A already exceeds 250 Ω, the resistor can be disconnected by changing the position of a jumper. The full burden voltage of 5 V is then available at output A instead of 0 V. External resistance I A R ext max. [kω] = Burden voltage I A2 5 V (0 V) I AN [ma] I AN = Output circuit full-scale value < 0.3 V (field indicator) External resistance I A2 R ext max. [kω] = Residual ripple Response time (IEC 770) Output characteristic 0.3 V I AN [ma] < % p.p., DC to 0 khz Approx. 200 ms Linear Measuring output Output signals A and A2 (see section Electrical connections ) The output signals A and A2 can be load-independent DC voltages U A or currents I A. A and A2 are not electrically insulated; the same value is available at both outputs. DC voltage signals U A Standard ranges for U A Non-standard ranges Short-circuit current Load-capacity U A /U A2 Load impedance U A /U A2 Residual ripple DC current signals I A Standard ranges for I A Non-standard ranges Open-circuit voltage Burden voltage I A 0 to 5, to 5, 0 to 0 or 2 to 0 V 0 to > 5 to 0 to 5 V resp. live-zero > ( to 5) to 3 to 5 V 40 ma 20 ma R ext A // R ext A2 [kω] < % p.p., DC to 0 khz 0 to 20 ma or 4 to 20 ma selected by jumpers 0 to to 0 to < 20 ma resp. live-zero 0.2 to to < (4 to 20) ma Approx. 7 to 22 V U A [V] 20 ma 5 V without communication 0 V (5 V) with communication* *When a hand-held terminal is connected to the field output A2, the voltage across the burden at output A reduces to 0 V. Digital communication requires a minimum burden at output A of 250 Ω. A 250 Ω resistor is therefore connected across the output circuit. Power supply H AC/DC power pack (DC and 45 to 400 Hz) Table Nominal voltages and tolerances Nominal voltage Tolerance U N 24 to 60 V DC / AC DC 5 to 33% 85 to 230 V AC ± 5% DC / AC 24 to 60 V DC / AC 85 to 230 V AC 85 to 0 V DC DC 5 to 33% AC ± 5% ± 0% 5 to 0% Standard (non-ex) Instrument version Type of protection Intrinsically safe [EEx ia] IIC For power supplies > 25 V, the auxiliary circuit should include an external fuse with a rating 20 A DC. Power input Communication Approx. 2.5 W resp. 4.5 VA Bi-directional communication of digital signals with an intelligent designed for and a HART or companyspecific protocol. Frequency range monitor Pick-up level 500 Hz to 35 khz Open-circuit Input current < 3.6 ma, adjustable in the works between and 4 ma Short-circuit Input current > 2 ma adjustable in the works between 20 and 23 ma 2 Data sheet B8- Le Camille Bauer

3 SINEA B8 Signalling modes Output signals A and A2 Frontplate signals Output contact Table 2 Type of output contact Symbol Material Gold flashed silver alloy Relay approved by UL, CSA, TÜV, SEV Direction of action Accuracy data (acc. to DIN/IEC 770) Output signal linear response For an open-circuit output 0 ma (with 4 to 20 ma) 5 ma (with 0 to 20 ma) For a short-circuit output approx. 26 ma Increasing output signal Output approx. 5% of fullscale value, e.g. 23 ma for output 0/4 to 20 ma or.5 V for output 0/2 to 0 V Decreasing output signal (only possible for live zero) Output approx. 0% of full-scale value, e.g. 2 ma for output 4 to 20 ma or V for output 2 to 0 V Failure signalled by red LED relay, potentially-free changeover contact (see Table 2) Contact rating AC 2 A / 250 V (500 VA) DC A / V (30 W) Adjustable by switch Relay energized or de-energized in the case of a failure Basic accuracy Limit erreur ± 0.2% Including linearity and reproducibility errors Burden influence Long-time drift Switch-on drift < ± 0.2% Common and transverse mode influence < ± 0.2% Output or connected to ground < ± 0.2% Regulations Electromagnetic compatibility < ± 0.% with current output < 0.2% with voltage output, if R ext > 2 R ext min. < ± 0.3% / 2 months The standards DIN EN and DIN EN are observed Intrinsically safe Acc. to DIN EN Electrical standards Acc. to IEC 00 resp. EN 6 00 Protection (acc. to IEC 529 resp. EN ) Housing IP 40 Terminals IP 20 Operating voltages Contamination level 2 Overvoltage category acc. to IEC 664 Double insulation Test voltage <300 V between all insulated circuits III for power supply II for measuring input, measuring output and output contact Power supply versus all other circuits, Measuring input versus measuring output and output contact Measuring output versus output contact Power supply versus measuring input, measuring output and output contact 3.7 kv, 50 Hz, min. Measuring input versus measuring output 2.3 kv, 50 Hz, min. Measuring output versus output contact 2.3 kv, 50 Hz, min. Reference conditions Ambient temperature Power supply Output burden Influencing factors Temperature 23 C, ± 2 K 24 V DC ± 0% and 230 V AC ± 0% Current 0.5 R ext max. Voltage 2 R ext min. < ± 0.% per 0 K Environmental conditions Commissioning temperature 0 to 55 C Operating temperature 25 to 55 C, Ex 20 to 55 C Storage temperature 40 to 70 C Annual mean relative humidity Vibration (IEC 68 T2/6) 75% standard climatic rating 95% enhanced climatic rating 2 g / 5 to 50 to 5 Hz; octave/min., 2 h Camille Bauer Data sheet B8- Le

4 SINEA B8 Shock (IEC 68 T2/27) Altitude Indoor use statement! Installation data Housing Material of housing 30 g / ms 2000 m max. Housing S7 See section Dimensional drawings for dimensions Lexan 940 (polycarbonate) flammability class V-0 acc. to UL 94, self-extinguishing, nondripping, free of halogen Mounting Position of use For snapping onto top-hat rail (35 x 5 mm or 35 x 7,5 mm) acc. to EN or directly onto a wall or panel using the pull-out screw hole brackets Any Terminals DIN/VDE 0609 Screw terminals with wire guards, for light PVC wiring and max. 2 x 0.75 mm 2 or x 2.5 mm 2 Weight Approx. 0.2 kg Standard version When ordering, it is only necessary to quote the Order No. Table 3 Instrument in version [EEx ia] IIC, (input circuit intrinsically safe) Version Order Code Order No. Supply voltage 6.9 V DC at 20 ma Power supply 85 to 0 V DC / 230 V AC Outputs A and A2* 4 to 20 ma, R ext 750 Ω (field communications protocol) Not designed for communications protocol fault detection Open-circuit < 3.6 ma, short-circuit > 2 ma Response to an input circuit Output signal linear response Response of the output contact for a measurement/supply circuit fault Without relay, without output contact Climatic rating Standard climatic rating 8-4B The complete order code according to Table 4 Specification and ordering information should be stated for other versions. * 2nd output signal A2 for field indicator only Table 4 Specification and ordering information (see also Table 3 Standard versions ) Description *Blocking code No-go with blocking code Article No./ Feature SINEA B8- Order Code 8-xxxx xxxx 8 Features, Selection. Mechanical design Housing S7 2. Version / Power supply H (nominal voltage U N ) Standard / 24 to 60 V DC/AC Standard / 85 to 230 V DC/AC 2 [EEx ia] IIC MSK intrinsically safe / 24 to 60 V DC/AC 3 [EEx ia] IIC MSK intrinsically safe / 85 to 0 V DC, 85 to 230 V AC 4 Lines 3 and 4 Instrument [EEx ia] IIC, input circuit (MSK) EEx ia IIC 4 Data sheet B8- Le Camille Bauer

5 SINEA B8 Description *Blocking code No-go with blocking code Article No./ Feature SINEA B8- Order Code 8-xxxx xxxx 8 Features, Selection 3. Output signals / measuring outputs A and A2** 0 to 5 V, R ext 250 Ω CD to 5 V, R ext 250 Ω C 2 0 to 0 V, R ext 500 Ω CD 3 2 to 0 V, R ext 500 Ω C 4 Non-standard [V] 0 to > 5 to 0 to 5 [V] CD 8 Live zero [V] > ( to 5) bis 3 to 5 [V] C 9 0 to 20 ma, R ext 750 Ω (500 Ω)*** DE A 4 to 20 ma, R ext 750 Ω (500 Ω)*** B Non-standard [ma] 0 to to 0 to < 20 [ma] CD Y Live zero [ma] 0.2 to to < (4 to 20) [ma] C Z 4. (field communications protocol) Not designed for communications protocol 0 Designed for communication, at field output A2 C ( 0 to 20 / 4 to 20 ma) Designed for communication, at measuring output A CE 2 ( 4 to 20 ma only) 5. fault detection Open / short-circuit detection Open-circuit < 3.6 ma; short-circuit > 2 ma 0 Open-circuit; short-circuit [ma] Open-circuit Values from to 4 ma Short-circuit Values from 20 to 23 ma e.g. [ma] 2;22 6. Response to an input circuit Output signal linear response 0 Increasing output signal >>> (Output approx. 5% of full-scale) Decreasing output signal <<< D 2 (Output approx. 0% of full-scale, with live zero signal only) 7. Response of the output contact for a measurement/supply circuit fault Without output contact 0 Output contact relay energized Output contact relay de-energized 2 8. Climatic rating Standard climatic rating 0 Improved climatic rating * Lines with letter(s) under No-go with blocking code cannot be combined with preceding lines having the same letter under Blocking code. ** A2 according to instrument version for connection with a field indicator or hand-held terminal only *** External resistance dependent on the position of jumper J 204 / J 205, see section technical data Measuring output Camille Bauer Data sheet B8- Le

6 SINEA B8 Table 5 Explosion protection data II () G Order code Type of protection [EEx ia] IIC Measuring circuit input U o = 2 V I o = 75 ma P o = 660 mw Trapezium characteristic IIC IIB L o 6.7 mh 25 mh C o 78 nf.26 µf Output, Power supply relays contacts U m = 253 V AC resp. 25 V DC Certificates PTB 97 ATE 2083 Mounting location Outside the hazardous area Electrical connections MSK Front GOSSEN METRAWATT SINEA B8 Space e.g. for MSK designation ON ON Green power on LED Red LED open and short-circuit monitor of input circuit MSK 4 9 A 3 8 A Without transparent cover HHT With transparent cover Relay b a c N/O contact N/C contact a c b c 5 0 H MSK A A2 HHT H = (terminal allocation according to type, see Table 6 ) = Measuring output = 2nd measuring output (field indicator) voltage drop across field indicator or milliammeter 300 mv, resp. connection for handheld terminal = Output contact for monitoring the input circuit (fault signalling output) Refer to the figure relay for details = Hand-held terminal = Power supply 6 Data sheet B8- Le Camille Bauer

7 SINEA B8 Configuration. Switching output signals A and A2 between the signal ranges 0 to 20 ma or 4 to 20 ma The range of the outputs can be switched from 0 to 20 ma to 4 to 20 ma or vice versa depending on the positions of jumpers J 202 and J 203 (Fig. 2). Output signals A / A2 Position of jumpers J 202 J to 20 ma 0 to 20 ma Communication connector Connect the communication connector to output A or A2 (Figures 5 to 8). Signals are then transferred in both directions between the hand-held terminal and the via the SINEA B 8. When using the field output A2, the 250 Ω burden connected across output A2 in the power supply unit can be switched in and out of circuit with the aid of jumpers J 204 and J 205 (Fig. 2). Communication connected to Field output A2* Integrated 250 Ω resistor in circuit The burden at measuring output A is reduced 250 Ω Choice of A output signal range 0/4 to 20 ma Voltage across A burden 0 V Field output A2* Integrated 250 Ω resistor not in circuit The burden at measuring output A is not reduced. A output signal range 4 to 20 ma only Voltage across A burden 5 V Measuring output A Output signal range 4 to 20 ma Voltage across A burden 5 V Position of jumpers J 204 J *See Measuring output in the Technical data section Fault Break Shortcircuit Output linear behaviour 0 ma ( 4 to 20 ma) 5 ma ( 0 to 20 ma) Approx. 26 ma 0/4 to 20 ma Output driving upscale Approx. 5% of full scale end value e.g. 23 ma 0/4 to 20 ma or.5 V 0/2 to 0 V Output driving downscale (with live-zero only) Approx. 0% of full scale end value e.g. 2 ma 4 to 20 ma or V 2 to 0 V 4. Response of the output contact for a fault in the measurement/supply circuit The response of the fault signalling relay can be set with the aid of switches 3 and 4 on the DIP switch S 20 (Fig. 2). Operating sense of the DIP switch S 20 fault signalling relay in the event of a fault Switch 3 Switch 4 Relay energised ON OFF Relay de-energised OFF ON ON OFF S J202 3 J203 3 J205 J Response of the output signals A and A2 for a fault in the measurement/supply circuit The response of the output signals A and A2 can be set with the aid of switches and 2 on the DIP switch S 20 (Fig. 2). Response of output signals A and A2 for a short or open-circuit of the measurement/supply circuit Dip switch S 20 Switch Switch 2 Linear output signal ON OFF Increasing output signal OFF OFF Decreasing output signal (only with live zero signal) OFF ON Fig. 2. Positions of the DIP switches S 20 and jumpers J 202 to J 205. Camille Bauer Data sheet B8- Le

8 SINEA B8 Table 6 Terminal allocation Hazardous area Connection of an HHT (terminals 2 and 7 connected directly to terminals and 6) Connection of an HHT (terminals 2 and 7 connected directly to terminals and 6) A A2 HHT A A2 *HHT Ex H ~ () ~ () H ~ () ~ () * Note data given in the conformity certificate. Fig. 3. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, not designed for. Fig. 4. SINEA Type , Intrinsically safe input circuit, supply voltage 6.9 V DC, not designed for. Hazardous area H ~ () ~ () A 0/ A2 HHT H ~ () ~ () A 0/ A2 HHT Fig. 5. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, designed for. Hand held terminal connected to field output A2. Fig. 6. SINEA Type , Intrinsically safe input circuit, supply voltage 6.4 V DC, designed for. Hand held terminal connected to field output A2. HHT = Hand-Held-Terminal Continuation of Table 6 Terminal allocation see on next page! 8 Data sheet B8- Le Camille Bauer

9 SINEA B8 Continuation Table 6 Terminal allocation Hazardous area A PLS/ SPS A PLS/ SPS A2 A2 H ~ () ~ () H ~ () ~ () Fig. 7. SINEA Type , Non-Ex input and output circuits, supply voltage 24 V DC, designed for. Processor connected to output A. Fig. 8. SINEA Type , Intrinsically safe input circuit, supply voltage 6.4 V DC, designed for. Processor connected to output A. Dimensional drawings 20 Standard accessories Operating Instructions in three languages German, French, English 2 Withdrawing handle (for opening the housing) 2 Labels (under transparent cover) Type examination certificate (only for Intrinsically safe explosion-proof devices) Fig. 9. SINEA B 8 in housing S7 clipped onto a top-hat rail (35 5 mm or mm, acc. to EN ) Ø4.5 Rely on us , Fig. 0. SINEA B 8 in housing S7 screw hole mounting brackets pulled out. Camille Bauer AG Aargauerstrasse 7 CH-560 Wohlen / Switzerland Phone Fax Subject to change without notice Edition Data sheet B8- Le

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar For electrically insulating, amplifying and converting DC signals 0102 II (1) G Application The purpose of the isolating amplifi er SINEAX TV 808 (Fig. 1 and 2) is to electrically insulate input and output

More information

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX TV809, 1 channel Programmable Isolating Amplifier For electrically insulating, ampliflying and converting DC signals 0102 II (1) Ga II (1) Da Application The purpose of the isolating amplifi er SINEAX TV809 (Fig. 1) is to electrically insulate input and

More information

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar for electrically insulating, amplifying and converting DC signals 0102 II (1) G pplication The purpose of the isolating amplifi er SIRX T 808 (Fig. 1) is to electrically insulate input and output signals,

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits SINEAX VC 603, Programmable for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Figs. 1 and 2) converts the input variable a

More information

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX SR 719 Programmable Transmitter for Position Feedback Position transmitter with NAMUR valve fitting Application The position feedback transmitter KINAX SR 719 (Figs. 1 and 2) is used to measure and transmit linear displacement (stroke) on various types of

More information

SINEAX V 604s Programmable multifunctional transmitter

SINEAX V 604s Programmable multifunctional transmitter SINEAX V 60s f direct currents, direct voltages, temperature senss, teletransmitters potentiometers 00 SINEAX V60s is a multifunctional transmitter f top-hat rail assembly with the following main characteristics:

More information

SINEAX VC 603, Programmable combined transmitter/alarm unit

SINEAX VC 603, Programmable combined transmitter/alarm unit for DC currents or voltages, temperature sensors, remote sensors or potentiometers 0102 II (1) G Application The SINEAX VC 603 (Fig. 1) converts the input variable a DC current or voltage, or a signal

More information

Isolators A3/1. Vibration Transducer Supply Unit Series

Isolators A3/1. Vibration Transducer Supply Unit Series > For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic

More information

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolators A3/1.  Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de

More information

KINAX 3W2 Transmitter for angular position

KINAX 3W2 Transmitter for angular position KINX 3W2 For installation KINX 3W2 is a compact transmitter for angular position for installation in devices and apparatus. Due to its unique capacitive measuring principle, it acquires the angular position

More information

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time

More information

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits

for DC currents or voltages, temperature sensors, remote sensors or potentiometers Application Principle of operation (Fig. 3) Features / Benefits for s or voltages, temperature sensors, remote sensors or potentiometers pplication The universal transmitter RISH Ducer V 604 (Figures 1 and 2) convert the input variable a or voltage, or a signal from

More information

Isolating Repeater Input Series 9163

Isolating Repeater Input Series 9163 > For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de

More information

Binary Output Series 9175

Binary Output Series 9175 Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN

Contrans T TEU 471, TEU 471-Ex. Intelligent four-wire temperature transmitters EN Contrans T TEU 471, TEU 471-Ex Intelligent four-wire temperature transmitters Input/sensor connection: Resistance thermometers (2-, 3-, 4-wire circuit) Thermocouples (without, with internal/external reference

More information

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications

More information

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3. TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex Transmitter for temperature and direct current variables in four-wire circuit Transmitters TEU 315 and TEU 325 are designed for direct and alternating voltage measurement

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

Temperature transmitter itemp PCP DIN rail TMT 121

Temperature transmitter itemp PCP DIN rail TMT 121 Technical information TI 087R/09/en 510 03671 Temperature transmitter itemp PCP DIN rail TMT 121 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage

More information

Temperature Measurement

Temperature Measurement Overview Application transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection head type B (DIN 4729) or larger. The following sensors/signal

More information

Remote Switching Unit nivotester FTL 320

Remote Switching Unit nivotester FTL 320 Technical Information TI 203F/24/ae Remote Switching Unit nivotester For connection to intrinsically safe Liquiphant level limit switches Applications Limit detection of fluids and bulk solids in tanks

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33 www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8

More information

LINAX 4000L Continuous-line recorder

LINAX 4000L Continuous-line recorder -48-852-0 4/2.99 1 to 4 line channels Format 144 mm x 144 mm, mounting depth 250 mm Combined recording table for roll chart (2 m) or fanfold chart (16 m) Measuring channels electrically isolated Rugged

More information

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

TR 104, TR 104-Ex Rail mounted Temperature Transmitters Data Sheet 10/-8.48-EN Rev. A TR 104, TR 104-Ex Rail mounted Temperature Transmitters Analog, Pt 100 (RTD), fixed measuring ranges Input Resistance thermometer (two-wire and three-wire circuit) Optionally

More information

Level Limit Switch nivotester FTL 370, FTL 372

Level Limit Switch nivotester FTL 370, FTL 372 Technical Information TI 98F/00/en Limit Switch nivotester FTL 370, FTL 37 With intrinsically-safe signal circuits for connection to sensors Liquiphant, Nivopuls, Soliphant. Features at a Glance High operational

More information

MINI-PS AC/24DC/1.3

MINI-PS AC/24DC/1.3 Power supply unit INTERFACE Data sheet 102894_en_03 1 Description PHOENIX CONTACT 2015-11-17 Features MINI POWER power supplies for MCR technology In measurement and control technology (MCR), modular electronics

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

itemp HART DIN rail TMT112

itemp HART DIN rail TMT112 Temperature transmitter itemp HART DIN rail TMT112 Universal temperature transmitter for resistance thermometers (RTD), thermocouples, resistance and voltage transmitters, incorporating HART protocol Application

More information

DEIF A/S. Insulation monitor. Type SIM-Q

DEIF A/S. Insulation monitor. Type SIM-Q Insulation monitor 4921232C Monitoring of insulation resistance on ungrounded AC networks (IT network) Working voltage up to 69V AC, withstands up to V DC Measuring range 1...Mohm or 1...Mohm Alarm on

More information

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35 www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up

More information

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No 9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used

More information

Preset counters, electronic

Preset counters, electronic The Codix 716 / 717 can be used universally. These preset pulse, tachometers or preset timers with up to 2 presets can solve a wide variety of control and monitoring tasks in every application. With their

More information

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet 1SVR 430 103 F0200 CT-ERS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: 49 661 60030 Fax: 49 661 6003607 Email: mail@jumo.net Internet: www.jumo.net JUMO

More information

Overcurrent Protection / 7SJ45

Overcurrent Protection / 7SJ45 Overcurrent Protection / SJ SIPROTEC easy SJ numerical overcurrent protection relay powered by CTs Fig. / Description SIPROTEC easy SJ numerical overcurrent protection relay powered by current transformers

More information

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002 Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation

More information

02/11/2015

02/11/2015 17.5 mm - 1 Relay 5A EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

For non-electrical quantities

For non-electrical quantities Controlgear 3UG3 monitoring relays 3RS17 interface converters N nsb0346h nsb0348h nsb0775h For electrical quantities For non-electrical quantities 3RS17 interface converter Selection and ordering data

More information

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems LIETRAXX -A etwork and system protection (S protection) for monitoring the power feed-in of power generation systems -A_D00001_01_D_XXE/09.2015 LIETRAXX -A etwork and system protection (S protection) for

More information

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages For the monitoring of voltages in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.: Extract from the online catalog MACX MCR-EX-T-UI-UP Order No.: 2865654 Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer

More information

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC Characteristics off-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Main Range of product Product or component type Discrete output type Width Device short name Time delay type Time delay range Nominal

More information

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet 2CDC 251 121 F0004 1 5 2 4 3 6 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the pulse time Remote potentiometer connection

More information

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/ 5. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/ 5 Order No.: 2866310 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 5 A Commercial data EAN 4046356046640 Pack 1 pcs. Customs

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 Overview SITANS TH00 two-wire system, universal, HAT Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relays CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS.81 The three-phase monitoring relay CM-PVS.81 monitors the phase parameters phase sequence, phase failure as well as over- and undervoltage. The device is

More information

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks. 2CDC 251 048 F0t08 CM-MPS.11 2CDC 251 049 F0t08 CM-MPS.21 2CDC 251 050 F0t08 CM-MPS.31 2CDC 251 051 F0t08 CM-MPS.41 R/T: yellow LED - relay status, timing F1: red LED - fault message F2: red LED - fault

More information

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 Data sheet Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81 The three-phase monitoring relays CM-PVS.x1 monitor the phase parameters phase sequence, phase failure as well as over-

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS

Related Products SDP Series SFL Series SCP Series SCL Series SDU UPS 4 Power Supplies SDN-P DIN Rail Series The SDN DIN Rail power supplies provide industry leading performance. Sag Immunity, transient suppression and noise tolerant, the SDN series ensures compatibility

More information

Temperature Measurement Transmitters for mounting in sensor head

Temperature Measurement Transmitters for mounting in sensor head Siemens AG 015 SITANS TH00 two-wire system, universal Overview Application SITANS TH00 transmitters can be used in all industrial sectors. Due to their compact size they can be installed in the connection

More information

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01

1-Phase True RMS AC/DC Over and Under Current Types DIC01, PIC01 Monitoring Relays -Phase True RMS AC/DC Over and Under Current Types DIC0, PIC0 DIC0 PIC0 TRMS AC/DC over + under, over+over, under+under current and voltage monitoring relays DC process signal plus/minus

More information

02/11/2015

02/11/2015 Modem communication plug and play solutions GSM Part number 88970119 For remote control of your application Automatic notification of alarms via SMS (GSM Modem) / email or on a PC with M3 ALARM software.

More information

CP-T range Product group picture

CP-T range Product group picture Product group picture /1 ABB Catalog Electronic Products and Relays 1/1 2CDC 110 00 C09 Table of contents CP-T range Product group picture /1 Table of contents /2 Benefits and advantages / Ordering details

More information

24/07/2012

24/07/2012 17.5 mm DIN rail mounting MURc3 Part number 88826503 Relay or solid state output Multi-function or mono-function Multi-range Multi-voltage Screw or spring terminals LED status indicator (relay version)

More information

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SL acc. to EC

More information

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max.

TMT Series, 10 to 50 Watt. Order Code Output Power Output 1 PCB-Mount Chassis Mount max. TMT Series, 10 to 50 Watt Features Ultra compact, fully encapsulated plastic case Single-, dual- and triple output models 2 package styles: - with screw terminal block for chassis mount - with solder pins

More information

RU Series Universal Relays

RU Series Universal Relays Full featured universal miniature relays Designed with environment taken into consideration Two terminal styles: plug-in and PCB mount Non-polarized LED indicator available on plug-in relays No internal

More information

05/09/2014

05/09/2014 48 x 48 Digital LCD Timer 814 Part number 88857005 Relay output digital timers LCD or LED (815E) Multi-range Multi-voltage 1 or 2 relay outputs Reset function on panel (Timers 815, 815E) Data saved in

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V 20 AMP POWER RELAY HG RELAYS a 3 1.4 5 RoHS Directive compatibility information http://www.nais-e.com/ a.0 50.0 1.99 8.0 2. FEATURES Large capacity 20 A 250 V AC resistive and 1.5 kw 3 phase 220 V AC motor

More information

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A

Circuit diagram. Applications. Function. Function (Continued) Page 23 SNO 4062K /K-A /KM /KM-A SNO 4062K Basic unit for emergency stop and guard door applications Basic unit as per DIN EN 60204-1 and EN ISO 13849-1 for single or twin channel emergency stop monitoring. PL e and category 4 as per

More information

XP2-R Power and Reverse Power Relay

XP2-R Power and Reverse Power Relay XP2-R Power and Reverse Power Relay Manual XP2-R (Revision C) Woodward Manual XP2-RE Woodward reserves the right to update any portion of this publication at any time. Information provided by Woodward

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

Analog signal converters CC range

Analog signal converters CC range Analog signal converters CC range Benefits and advantages 2CDC 28 Fb Product range for analog signal processing CC-U range 8 different standard signal outputs on one device Input and output side universally

More information

PHOENIX CONTACT - 09/2009

PHOENIX CONTACT - 09/2009 Electronic miniature circuit-breaker CLIPLINE Data sheet 03906_en_0 PHOENIX CONTACT - 09/2009 Description The EC-E... electronic miniature circuit-breaker selectively protects all 24 V DC load circuits

More information

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys

TSX Series. Modicon Manuals. Presented by: Modicon PLC. Schneider Electric Quantum Modicon Gould Gettys TSX Series Modicon Manuals Presented by: Modicon PLC Schneider Electric Quantum Modicon Gould Gettys For Product Needs: Email: sales@modiconplc.com Call: 1-800-691-8511 Fax: 919-415-1614 ModiconPLC.com

More information

Weighing Instruments

Weighing Instruments GHM Messtechnik GmbH Sales Center International Schloßstraße 6 88453 Erolzheim Germany Fon +49-7354-937233-0 Fax -88 www.ghm-messtechnik.de info@ghm-messtechnik.de Weighing Instruments System Evaluation

More information

Installation guide 877 FDI Field Display & Interface

Installation guide 877 FDI Field Display & Interface Installation guide 877 FDI Field Display & Interface November 2008 Part no. 4416.264 Rev. 5 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com

More information

Model Number Structure

Model Number Structure General-purpose Relay MK-I/-S Electromechanical Relays Exceptionally Reliable General-purpose Relay Features Mechanical Indicator/Push Button Breaks relatively large load currents despite small size. Long

More information

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Current / residual current and voltage transformers. Current / residual current and voltage transformers Current / residual current and voltage transformers Current / residual current and voltage transformers 1 Overview Current transformer overview DIN rail current transformer with fuse Current transformer...

More information

QUINT-PS/ 3AC/24DC/40

QUINT-PS/ 3AC/24DC/40 Primary-switched power supply unit with SFB technology, 3 AC, output current 40 A INTERFACE Data sheet 103133_en_00 1 Description PHOENIX CONTACT - 07/2009 Features QUINT POWER power supply units Maximum

More information

Fieldbus Isolating Repeater Series 9185/11

Fieldbus Isolating Repeater Series 9185/11 www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,

More information

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Weighing System Evaluation Mounting DMS strain gauges (load cells), DMS amplifier

More information

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact Data sheet Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact The CT-EBE is an electronic time relay with the function flasher starting with OFF. It is from the CT-E range. The CT-E

More information

CP-T range Benefits and advantages

CP-T range Benefits and advantages Benefits and advantages Characteristics Rated output voltages V, V DC Output voltage adjustable via front-face rotary potentiometer OUTPUT Adjust Rated output currents 5 A, 10 A, A, A Rated output powers

More information

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New)

XP2-R Power and reverse power relay. (January 2006) Manual XP2-R (Revision New) XP2-R Power and reverse power relay (January 2006) Manual XP2-R (Revision New) Woodward Manual XP2-R GB Woodward Governor Company reserves the right to update any portion of this publication at any time.

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

02/11/2015

02/11/2015 DIN Rail Mount 17.5 mm MURc3 Part number 88826503 DIN Rail Mount 17.5 mm MURc3 Part number 88826503 Just one digit differentiates the new range part number from the old range's Previous part number : 88

More information

Installation guide 873 SmartRadar Control Unit & Antenna Unit

Installation guide 873 SmartRadar Control Unit & Antenna Unit Installation guide 873 SmartRadar Control Unit & Antenna Unit Rev. 7 January 2006 Part no. 4416.569 Enraf BV PO Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : info@enraf.nl

More information

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC Data sheet Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 AC The CM-IWS.2 serves to monitor insulation resistance in accordance with IEC 61557-8 in unearthed IT AC systems

More information

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans

LCL Series. SIngle Output Industrial Supplies. High Efficiency. Low Cost. 150 W Convection Cooled. 300 W & 500 W with Internal Fans LCL Series SIngle Output Industrial Supplies High Efficiency Low Cost 150 W Convection Cooled 300 W & 500 W with Internal Fans Outputs form 12 V to 48 V 3 Year Warranty The LCL series is a low cost chassis

More information

02/11/2015

02/11/2015 Smart "Compact" range with display CD20 Smart Part number 88974053 Highly visible blue LCD with 4 lines of 18 characters and configurable backlighting Allow the use of the entire library of specific functions

More information

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description Photoelectrics, Background suppression reflective - PointSpot Main features Miniature sensor range The visible red PointSpot light makes alignment very easy Range: 250 mm Sensitivity adjustment by potentiometer

More information

PCB relay for DC voltage, polarized, monostable or bistable

PCB relay for DC voltage, polarized, monostable or bistable V23042 PCB relay for DC voltage, polarized, monostable or bistable Features Universally applicable in the most varied circuit functions in the field of telecommunications and small signal technology Versatile

More information

Electronic Step Controller

Electronic Step Controller 4 915 Electronic Step Controller, Adjustable switch-on delay (typically used to prevent current surges on startup and after a power failure) Adjustable switch-on points Adjustable switching differential

More information

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity

Technical data. Functional safety related parameters MTTF d. Transfer characteristics. Time delay before availability. Standard conformity KFU8-DW-.D Release date: 2-2- 2:8 Date of issue: 26-8- 4_eng.xml Model Number KFU8-DW-.D Rotation Speed Monitor Features Speed monitoring up to 4 khz pre-select value with relay output and LED indicator

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions

DT1100 xx xx xx PS. Isolators, Isolator / Power Supplies. Operating Instructions Isolators, Isolator / Power Supplies Operating Instructions EN Contents 1. About this document...4 1.1. Function... 4 1.2. Target group... 4 1.3. Symbolism used... 4 2. For your safety...5 2.1. Authorized

More information

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O

RE22R2MMU Multifunction Timer Relay - 24VDC/ V AC - 2 C/O Product data sheet Characteristics RE22R2MMU Multifunction Timer Relay - 24VDC/24..240 V AC - 2 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output

More information

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply with SFB technology, 1 AC, output current 20 A INTERFACE Data Sheet 103383_en_00 1 Description PHOENIX CONTACT - 06/2008 Features QUINT POWER power supply units highest system

More information