FOR RELIABLY MEASURING +

Size: px
Start display at page:

Download "FOR RELIABLY MEASURING +"

Transcription

1 in(f)a22 ina05-09 ina14 PROXIMITY SWITCHES FOR RELIABLY MEASURING + EVALUATING MOVEMENTS

2 T H E PROXIMITY SWITCHES O F T I E F E N B A C H C O N T R O L S Y S T E M S >>> HAVE BEEN ESPECIALLY DEVELOPED FOR THE RELIABLE, WEAR-FREE AND MAINTENANCE-FREE MEASUREMENT AND EVALUATION OF MOVEMENTS AS INSTRUMENT FOR MONITORING CONVEYOR AND CRANE SYSTEMS, TRANSFER LINES, BELT TRACK; AND MACHINE CONTROLS. The almost inertia-free lnamur-type proximity switches are two-wire sensors and provide an electrically processible signal when actuated. The non-contact position measurement is effected by means of magnets or metallic targets which cause an attenuation of the oscillator when approaching the active sensing surface. Thanks to the use of corrosion-resistant materials the proximity switches are largely unaffected by external influences. They can be installed in any desired position. All proximity switches are certified according to Directive 94/9/EC (ATEX). >>> TIEFENBACH CONTROL SYSTEMS OFFERS OPTIMUM SOLUTIONS FOR THE MOST VARIED MEASUREMENT + EVALUATION OF MOVEMENT APPLICATIONS

3 P R O X I M I T Y S W I T C H in(f)a22 non-contact signal transmitter acc. to EN (NAMUR) Nominal switching distance 10 mm Operation by means of a metal target (variant ina22) Operation by means of a magnet (version infa22) Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 54 according to EN 60529/IEC 529; EEx ia I intrinsically safe according to Directive 94/9/EC (ATEX) P R O X I M I T Y S W I T C H ina05-09 non-contact signal transmitter acc. to EN (NAMUR) Small in size Nominal switching distance 1 mm (ina05) and 2 mm (ina09) Operation by means of a metal target Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 65 according to EN 60529/IEC 529; EEx ia I intrinsically safe according to Directive 94/9/EC (ATEX) P R O X I M I T Y S W I T C H ina14 non-contact signal transmitter acc. to EN (NAMUR) Nominal switching distance 5 mm Operation by means of a metal target Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 65 according to EN 60529/IEC 529; EEx ia I intrinsically safe according to Directive 94/9/EC (ATEX)

4 Tiefenbach Control Systems GmbH Rombacher Hütte 18a Bochum Telephone +49 (0) Fax +49 (0)

5 Proximity switch ina05 ina09 non-contact signal transmitter acc. to EN (NAMUR) Small in size Nominal switching distance 1 mm (ina05) and 2 mm (ina09) Operation by means of a metal target Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 65 according to EN 60529/IEC 529 Ex-approval: I M2 EEx ia I intrinsically safe acc. to Directive 94/9/EC (ATEX) Switching current window Speed sensing with proximity switches acc. to NAMUR

6 ina05/09 ina05 ina09 L L D 4 4 d1 Ø12 Ø15 d2 M8x1 M12x1 SW variant with collar variant without collar active sensing surface

7 ina05/09 FUNCTION AND DESIGN NAMUR proximity switches are two-wire sensors which detect metallic materials without contacting them. Physically, metal approaching the active sensing surface attenuates the oscillator in the proximity switches, that is it decreases the oscillating amplitude. Attenuation is effected by means of metallic targets. The nominal distance stated in the technical data refers to a target made of S235 (St 37) steel. When using other metallic materials reductions of the distance have to be taken into consideration. When the oscillator is attenuated a current change occurs which is identical with the output switching command. For triggering the switching command it is of no importance whether non-metallic materials such as e.g. glass, plastic, or rubber are located between the metallic target and the active sensing surface. Another positive feature of the oscillator is its high degree of safety against interfering pulses. Due to the response time of the proximity switch and particularly of the control device a minimum switching sector length is required which determines the duration of the attenuation. Deattenuation requires a pause sector of at least twice the length. The proximity switches can be used for controlling safety-relevant control and monitoring circuits. The respective criteria are defined in EN (NAMUR). Irrespective of the status of the control they allow to permanently monitor lines and cables for broken conductors and short circuits. The electronic components are embedded in cast resin. The solid construction with the brass housing ensures adequate safety with respect to explosion protection and mechanical damage. Application The proximity switch can be used in all applications where motions have to be detected and evaluated. It is thus used as control and monitoring organ in conveyor and crane installations, transfer lines, machine control systems, as well as for solving general automation problems. Thanks to its small size it is particularly suitable for speed sensing in gearboxes and other mechanisms with a confined space. It is possible to install the proximity switch flush in metal (shielded). This arrangement, however, already causes an attenuation of the oscillator. Therefore, the switching distance to the metal target has to be reduced. Response curve: Targetsurface Proximity switch Deactivation curve Hysteresis Determination switching target length: a = size ina05: 05 = size a= 5 mm ina09: 09 = size a= 9 mm Activation curve Sensor Active sensing surface Switching target Attenuation (pulse) = a Deattenuation (pause) = 2 a Nominal switching distance Sn: see technical data (This applies to a circumferential speed of the switching target of up to 7.5m/s. If the circumferential speed is higher a larger switching target will be required. Please contact us if that situation occurs.)

8 ina05/09 TECHNICAL DATA Nominal switching distance Sn ina05 ina09 for S235 (St 37) 1 mm 2 mm for nickell 0,85 mm 1,7 mm for messing 0,55 mm 1,1 mm for aluminium 0,50 mm 1,0 mm for copper 0,45 mm 0,9 mm Size of the target ina05 8 x 8 x 2 mm ina09 12 x 12 x 2 mm Switching frequency 5000 Hz Control signal based on EN (NAMUR) Nominal voltage up to 12 VDC NAMUR sensor Nominal operation I attenuated 1,2 ma Π (Uo = 8,2 VDC, Ri = 1 kω) I deattenuated 2,1 ma Hysteresis 1-5 % Repeat accuracy < 2 % Temperature range -20 C to 85 C Installation flush mounting in metal possible Type of protection IIP 65 acc. to EN / IEC 529 Ex-approval I M2 EEx ia I acc. to Directive 94/9/EG (ATEX) Certificate number DMT 00 ATEX E 036 X R i =1 k + 8,2 VDC Evaluation 0 V TYPE CODE AND ORDERING INFORMATION ina* * -1 * - * * * - * * Nominal switching distance in mm (not applicable for switches sensitive to magnets) Type 231 only ina05 screw-in thread M8x1 232 only ina09 screw-in thread M12x1 Type of connection: S connector L cable 1 Type NAMUR mount Coil size in mm Design acc. to ATEX Proximity switch Intrinsically safe TYPICAL EXAMPLE ina05-1l L=2 m ina09-1s L=4 m with collar ina09-1s L=4 m w/o collar W e g i v e i m p u l s e s > > > Intrinsically safe proximity switch acc. to ATEX Coil size 5 mm Type NAMUR mount Intrinsically safe proximity switch acc. to ATEX Coil size 9 mm Type NAMUR mount Intrinsically safe proximity switch acc. to ATEX Coil size 9 mm Type NAMUR mount Connection via cable 2 m long Housing with screw-in thread M8x1 Nominal switching distance 1 mm Connection via cable 4 m long Housing with screw-in thread M12x1 Nominal switching distance 2 mm Housing with stop angle Connection via cable 4 m long Housing with screw-in thread M12x1 Nominal switching distance 2 mm Housing without stop angle Subject to technical alterations Version 08/12 Tiefenbach Control Systems GmbH Rombacher Hütte 18a Bochum Telephone +49 (0) Fax +49 (0) info@tiefenbach-controlsystems.com

9 Proximity switch ina14 non-contact signal transmitter acc. to EN (NAMUR) Nominal switching distance 5 mm Operation by means of a metal target Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 65 according to EN 60529/IEC 529 Ex-approval: I M2 EEx ia I intrinsically safe according to Directive 94/9/EC (ATEX) Belt track monitoring with the proximity switch ina14

10 ina14 active sensing surface

11 ina14 FUNCTION AND DESIGN NAMUR proximity switches are two-wire sensors which detect metallic materials without contacting them. Physically, metal approaching the active sensing surface attenuates the oscillator in the proximity switches, that is it decreases the oscillating amplitude. Attenuation is effected by metallic targets. The nominal distance stated in the technical data refers to a target made of S235 (St 37) steel. When using other metallic materials reductions of the distance have to be taken into consideration. Attenuating the oscillator results in a current change which is identical with the output switching command. For triggering the switching command it is of no importance whether non-metallic materials such as e.g. glass, plastic, or rubber are located between the metallic target and the active sensing surface. Another positive feature of the oscillator is its high degree of safety against interfering pulses. Due to the response time of the proximity switch and particularly of the control device a minimum switching sector length is required which determines the duration of the attenuation. Deattenuation requires a pause sector of at least twice the length. The proximity switches can be used for controlling safety-relevant control and monitoring circuits. The respective criteria are defined in EN (NAMUR). Irrespective of the status of the control they allow to permanently monitor lines and cables for broken conductors and short circuits. The electronic components are embedded in cast resin. The solid construction with the brass housing ensures adequate safety with respect to explosion protection and mechanical damage. Application The proximity switch can be used in all applications where motions have to be detected and evaluated. It is thus used as control and monitoring organ in conveyor and crane installations, transfer lines, machine control systems, as well as for solving general automation problems. It is possible to install the proximity switch flush in metal (shielded). This arrangement, however, already causes an attenuation of the oscillator. Therefore, the switching distance to the metal target has to be reduced. Response curve: Targetsurface Proximity switch Deactivation curve Sensor Hysteresis Determination switching target length: a = size ina14: 14 = size a= 14 mm Activation curve Active sensing surface Switching target Attenuation (pulse) = a Deattenuation (pause) = 2 a Nominal switching distance Sn: see technical data (This applies to a circumferential speed of the switching target of up to 7.5m/s. If the circumferential speed is higher a larger switching target will be required. Please contact us if that situation occurs.)

12 ina14 TECHNICAL DATA Nominal switching distance Sn for S235 (St 37) 5 mm for nickel 4,25 mm for messing 2,75 mm for aluminium 2,50 mm for copper 2,25 mm Size of the target 18 x 18 x 2 mm Switching frequency 1000 Hz NAMUR sensor Control signal based on EN (NAMUR) Nominal voltage up to 12 VDC Π Nominal operation I attenuated 1,2 ma (Uo = 8,2 VDC, Ri = 1 kω) I deattenuated 2,1 ma Hysteresis 1-5 % Repeat accuracy < 2 % Temperature range -20 C to 85 C Installation flush mounting in metal possible Type of protection IP 65 acc. to EN / IEC 529 Ex-approval I M2 EEx ia I acc. to Directive 94/9/EG (ATEX) Certificate number DMT 00 ATEX E 036 X R i =1 k + 8,2 VDC Evaluation 0 V TYPE CODE AND ORDERING INFORMATION i N A * * -1 * - * * * - * * Nominal switching distance Sn in mm Type: 234 screw-in thread M18x1 Type of connection: L cable K terminal 1 electric design acc. to DIN Size in mm Design acc. to ATEX N operated to metallic switching target Intrinsic design TYPICAL EXAMPLE ina14-1l L=2 m ina22-1k Intrinsically safe proximity switch, operated to metallic switching target Connection via cable Intrinsically safe proximity switch, operated to metallic switching target Connection via terminal Screw-in thread M18 x1 Nominal switching distance 5 mm With connection cable 2 m long Screw-in thread M18 x1 Nominal switching distance 5 mm Subject to technical alterations Version 08/12 W e g i v e i m p u l s e s > > > Tiefenbach Control Systems GmbH Rombacher Hütte 18a Bochum Telephone +49 (0) Fax +49 (0) info@tiefenbach-controlsystems.com

13 Proximity switch in(f)a22 non-contact signal transmitter acc. to EN (NAMUR) Nominal switching distance 10 mm Operation by means of a metal target (variant ina22) Operation by means of a magnet (version infa22) Almost inertia-free due to an electronic oscillator circuit High safety against interfering pulses Wear-resistant and maintenance-free Type of protection: IP 54 according to EN 60529/IEC 529 Ex-approval: I M2 EEx ia I intrinsically safe according to Directive 94/9/EC (ATEX) Monitoring the closing action at the pipe piston conveyor

14 in(f)a22

15 in(f)a22 FUNCTION AND DESIGN NAMUR proximity switches are two-wire sensors which detect metallic materials without contacting them. Physically, metal approaching the active sensing surface attenuates the oscillator in the proximity switches, that is it decreases the oscillating amplitude. Attenuation can be effected by metallic targets on the inductive proximity switches ina22 magnets on the inductive proximity switches infa22 The nominal distance stated in the technical data refers to a target made of S235 (St 37) steel. When using other metallic materials reductions of the distance have to be taken into consideration. When the oscillator is attenuated a current change occurs which is identical with the output switching command. For triggering the switching command it is of no importance whether non-metallic materials such as e.g. glass, plastic, or rubber are located between the metallic target or the permanent magnet and the active sensing surface. Another positive feature of the oscillator is its high degree of safety against interfering pulses. Due to the response time of the proximity switch and particularly of the control device a minimum switching sector length is required which determines the duration of the attenuation. Deattenuation requires a pause sector of at least twice the length. Application The proximity switch can be used in all applications where motions have to be detected and evaluated. It is thus used as control and monitoring organ in conveyor and crane installations, transfer lines, machine control systems, as well as for solving general automation problems. It is possible to install the proximity switch flush in metal (shielded). This arrangement, however, already causes an attenuation of the oscillator. Therefore, the switching distance to the metal target or the magnet has to be reduced. Response curve: Targetsurface Proximity switch Deactivation curve Hysteresis Determination switching target length: Activation curve Active sensing surface The proximity switches can be used for controlling safety-relevant control and monitoring circuits. The respective criteria are defined in EN (NAMUR). Irrespective of the status of the control they allow to permanently monitor lines and cables for broken conductors and short circuits. The electronic components are embedded in cast resin. The solid construction with the brass housing ensures adequate safety with respect to explosion protection and mechanical damage. a = size in(f)a22: 22 = size a= 22 mm Sensor Switching target Attenuation (pulse) = a Deattenuation (pause) = 2 a Nominal switching distance Sn: see technical data (This applies to a circumferential speed of the switching target of up to 7.5m/s. If the circumferential speed is higher a larger switching target will be required. Please contact us if that situation occurs.)

16 in(f)a22 TECHNICAL DATA Nominal switching distance Sn for S235 (St 37) 10 mm for aluminium 5 mm for nickel 8,5 mm for copper 4,5 mm for messing 5,5 mm Size of the target 22 x 22 x 2 mm Switching frequency 400 hz Control signal based on EN (NAMUR) Nominal voltage up to 12 VDC NAMUR sensor Nominal operation I attenuated 1,2 ma Π (Uo = 8,2 VDC, Ri = 1 kω) I deattenuated 2,1 ma Hysteresis 1-5 % Repeat accuracy < 2 % Temperature range -20 C to 85 C Installation flush mounting in metal possible Type of protection IP 54 acc. to EN / IEC 529 Ex-approval I M2 EEx ia I acc. to Directive 94/9/EG (ATEX) Certificate number DMT 00 ATEX E 036 X R i =1 k + 8,2 VDC Evaluation 0 V TYPE CODE AND ORDERING INFORMATION i N * A * * -1 * - * * * - * * short/long Short or long variant Nominal switching distance Sn in mm Type: 165 screw-in thread PG diameter 28 mm 289 screw-in thread PG21 -type 90 -angle 631 screw-in thread M32x1,5 Type of connection: S connector L cable K terminal 1 electric design according to DIN Size in mm Design acc. to ATEX F magnet-operated N operated to metallic switching target Intrinsically safe TYPICAL EXAMPLE infa22-1s short L=5m ina22-1s long L=3m W e g i v e i m p u l s e s > > > Intrinsically safe proximity switch, magnet-operated Connection via connector Screw-in thread PG21 Intrinsically safe proximity switch, operated to metallic switching target Connection via connector Screw-in thread M32x1,5 Nominal switching distance 10 mm Short variant With connection cable 5 m long Nominal switching distance 10 mm Long variant With connection cable 3 m long Subject to technical alterations Version 08/12 Tiefenbach Control Systems GmbH Rombacher Hütte 18a Bochum Telephone +49 (0) Fax +49 (0) info@tiefenbach-controlsystems.com

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Inductive sensor slot-type SI2-K08-AP7

Inductive sensor slot-type SI2-K08-AP7 SI2-K08-AP7 Slot sensor, height 8 mm Plastic, polypropylene Mechanical end stop, removable, for analog pointer instruments 3-wire DC, 10 30 VDC NO contact, PNP output Cable connection Wiring diagram Type

More information

Operating Instructions

Operating Instructions Operating Instructions FLUDEX-EOC system A. Friedr. Flender AG 46393 Bocholt Tel. 02871/92-0 Telefax 02871/92-2596 www.flender.com Contents 1. Application 3 2. Operation 3 3. Fitting 4 3.1 Fitting transmitter

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Inductive Proximity Detectors Technical Guide

Inductive Proximity Detectors Technical Guide Operating principles Figure 1 illustrates the principle of an Inductive Proximity Detector (I.P.D.) M Method of measuring sensing distances: according to standard EN 50010. Lateral approach and axial approach:

More information

Certified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver

Certified according to DIN EN ISO Technical Datasheet. FOP 60 and OPTV. Fibre-Optic Amplifier and Receiver Certified according to DIN EN ISO 9001 Technical Datasheet FOP 0 and OPTV Fibre-Optic Amplifier and Receiver Description... 3 Technical Data... 3 Electrical Connections... 7 Ordering Information... 8 Marking...

More information

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

Order/Technical Support Tel: (800) / FAX: (800) /

Order/Technical Support Tel: (800) / FAX: (800) / Key-operated safety interlock switch, plastic Without key locking Switches with plastic body for use on light machinery, without inertia. For use in unstable environments where there is a risk of the guard

More information

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable

Highlights. SIMATIC PXI inductive proximity switches. Introduction. Inductive proximity switches rugged, accurate and reliable Siemens G 008 SIMTIC PXI inductive proximity switches Introduction Inductive proximity switches rugged, accurate and reliable PXI series The inductive proximity switches are organized in different product

More information

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones

Isolating Spark Gaps. Isolating spark gaps at an additional earth ring conductor. Isolating spark gaps for Ex zones Isolating Spark Gaps Isolating spark gaps at an additional earth ring conductor Isolating spark gaps for Ex zones 187 Protective Spark Gaps For use at roof supports for overhead lines For indirect connection

More information

VTM Local Display Unit with Frequency and Analogue Output

VTM Local Display Unit with Frequency and Analogue Output Küppers Elektromechanik GmbH Flow Meters Liebigstr. 2 D-85757 Karlsfeld Phone +49 81 31/59 39 10 Fax + 49 81 31/9 26 04 VTM Local Display Unit with Frequency and Analogue Output The VTM is a programmable

More information

Page Type Resolution (mm) min. max. Output

Page Type Resolution (mm) min. max. Output Data Sheet Overview -1- Page Type Resolution (mm) min. max. Output Ind. lenght Ind. lenght 2 XM/XT-800E 5 +/- 2 400 mm 3000 mm current/voltage 6 XM/XT-825E 2.5 +/- 1 200 mm 1500 mm current/voltage 10 XM/XT-800E-PVDF

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0

Specifications (in accordance with DIN 16086) Equipment family Digibar II Type 1-PE50A1/...; K-PE PE00A1/...; K-PE00... Class of accuracy 0.2 0 Digibar II: PE00, PE50 Digital pressure gage Special features Data Sheet PE00 PE50 Operated as manometer with battery operation and Operated as pressure measurement transmitter with 420 current output,

More information

... for hydraulic and general applications in hazardous areas

... for hydraulic and general applications in hazardous areas ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified

More information

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition Converter Connection 1-channel EEx ia IIC for 4-wire and 6-wire bridges Analogue output 0/4 ma... 20 ma or 4mA...-12mA Full bridge load cells and strain gauges circuit for resistance bridges up to 17 Ω

More information

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples

More information

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009

SITRANS F flowmeters. SITRANS F R Rotary-piston meters Accessory modules 4/431. Overview. Siemens AG 2009 Siemens AG 2009 SITRANS F flowmeters Rotary-piston meters Accessory modules Accessory modules For quantity measurements in conjunction with electromechanical and electronic pulse counters As transmitter

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/ 3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging

More information

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry

More information

Valves, Actuators, Accessories. N Series Solenoid Valve

Valves, Actuators, Accessories. N Series Solenoid Valve Valves, Actuators, Accessories N eries olenoid Valve Technical Data Function Manual override Design Mounting Mounting position Material specifications Media Fluid temperature Electrical parts Voltage Voltage

More information

Technical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver

Technical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver www.kem-kueppers.com info@kem-kueppers.com Technical Datasheet FOP 60 and OPTV Fibreoptical Amplifier and Lightpulse Receiver Certified according to DIN EN ISO 9001 2 FOP 60 and OPTV Fibre-Optic Amplifier

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite KFS Flap Flow Meter KFS suitable for H, acids, alkalis and gases spring-loaded horizontal or vertical flow direction low pressure loss mainly viscosity independent optional threshold value contacts optional

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

TMU. Coriolis Mass Flow Meter. for liquids and gas

TMU. Coriolis Mass Flow Meter. for liquids and gas Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TMU S5 OO Measuring range: 0-60 kg/h 0-2200 t/h water OO Accuracy: ± 0.1% of reading ±zero point stability (from liquids up to

More information

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES Non-contacting measurement system based on eddy current principle Certified for use in potentially

More information

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx.

Any installation position possible. 1K5, but C. < 2 % of the control range. < 0,2 % / 0,1 bar, type 824.P < 0,1 % / 0,1 bar. Approx. General data Mounting Enclosure material On linear actuators On quarter-turn actuators ARCA-integrated or acc. to IEC 534-6 (NAMUR) Range of stroke 10... 120 mm ARCA-integrated or acc. to VDI/VDE 3845

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

Induct. Inductive proximity sensors. Inductive sensors. Double sensing range. Triple sensing range. Single sensing range. Flush installation

Induct. Inductive proximity sensors. Inductive sensors. Double sensing range. Triple sensing range. Single sensing range. Flush installation Inductive sensors Inductive proximity sensors Single sensing range Double sensing range Triple sensing range Flush installation Cylinder housing Threaded cylinder housing Cuboid housing Non-flush installation

More information

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays KSR-Level sensor KSR-Schwimmer-Magnetschalter 1001-5 KSR Contact Protection s 1 KSR Contact Protection Type KR230-Ex and KR24-Ex General Description The contact protection relays KR230-Ex and KR24-Ex transmit

More information

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden Germany

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden   Germany Temperature sensor PR-SPA-EX-NWT 1. Manufacturer and distributor EPHY-MESS GmbH phone: +49 6122 9228-0 Berta-Cramer-Ring 1 fax: +49 6122 9228-99 65205 Wiesbaden email: info@ephy-mess.de Germany 2. Applied

More information

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner TQ 402 & TQ 412 / EA 402 / IQS 452 FEATURES Non-contacting measurement system based on eddy current principle Certified

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version Electrical temperature measurement Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 Applications Process industry Machine building

More information

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN Indicator and alarm signalling unit 10/30-2.10 EN Dimensions 36 mm x 144 mm Can either stand vertically or lie horizontally Comprehensively explosion-protected Robust moving-coil system Contactless alarm

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features:

LVDT. Inductive Position Transducer - Hydraulic Series. SM-HYD Hydraulic Series. Key-Features: LVDT Inductive Position Transducer - Hydraulic Series SM-HYD Hydraulic Series Key-Features: Content: - Screw flange M18x1,5 / M30x1,5 or plug-in flange Ø18 - Pressure up to 400 bar - Measurement range

More information

Density meter DWF. Device description. Device description DWF Page 1 of 22

Density meter DWF. Device description. Device description DWF Page 1 of 22 Density meter DWF Device description Device description DWF Page 1 of 22 Table of Contents 1. Definition of the device 4 1.1 Vendor / Manufacture 4 1.2 Product type and designation 4 1.3 Manual issue date

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information

Relative and absolute pressure transmitter type 528

Relative and absolute pressure transmitter type 528 Relative and absolute pressure transmitter type 528 The compact type 528 pressure transmitter is based upon the Huba Control developed and since over 20 years well proven ceramic technology. These transmitters

More information

Proximity Sensor Terminology

Proximity Sensor Terminology The following descriptions refer to the European standard EN 60947-5-2. of 2007. The specifications given here are intended to be minimum performance values described by the standard. Alignment must not

More information

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution Features TTL output driver for cable length up to 550 m Very high resistance to shock and vibrations Hybrid bearing for extended service life Shaft insulation up to.8 kv Large terminal box, turn by 80

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Inductive proximity switches IFL

Inductive proximity switches IFL IFL Design and voltage variants Overview Design Cylindrical design Thread design Dimensions [mm] Designation DC 3-wire DC 4-wire Ø 6.5 IFL -6.5-.. Page 18 Ø 20 IFL -200- Page 16 Ø 40 IFL -400- Page 16

More information

More Precision. mainsensor // Magneto-inductive displacement sensors

More Precision. mainsensor // Magneto-inductive displacement sensors More Precision mainsensor // Magneto-inductive displacement sensors 2 Magneto-inductive sensors for non-contact linear displacement measurement mainsensor - Selectable measuring ranges up to 55mm - Linear

More information

PROXIMITY SENSOR TERMINOLOGY

PROXIMITY SENSOR TERMINOLOGY Never use this desk reference for installation or operation of equipment. Refer to manual for installation and operation instructions. The following descriptions refer to the European standard EN 60947-5-2.

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Pulse Scaler for DIN Rail Attachment

Pulse Scaler for DIN Rail Attachment Type 651 Pulse Scaler for DIN Rail Attachment Programmable pulse scaling factor up to 2047:1 NAMUR generator input PNP transistor output Max. pulse frequency 5 khz PROGRAMMING The divisor is set in binary

More information

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0) DMP 4 Industrial Pressure Transmitter Without Media Isolation accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 0 mbar up to 0... 000 mbar Product characteristics excellent linearity

More information

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments WIKA Data Sheet PE 81.51 Applications

More information

Inductive Analog-Sensors

Inductive Analog-Sensors SENSOREN FÜR AUTOMATION Inductive Analog-Sensors Item group 260 Non-contacting measurement of distance and position -Distance -Displacement -Position -Edge guiding -Concentricity -Centering -Sorting -Counting

More information

Head mounted Temperature Transmitter TF02/TF02-Ex

Head mounted Temperature Transmitter TF02/TF02-Ex Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance

More information

Wind Transmitter First Class Advanced Classified according to IEC ( )

Wind Transmitter First Class Advanced Classified according to IEC ( ) THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021519/01/09 Wind Transmitter First Class Advanced Classified according to IEC 61400-12-1 (2005-12)

More information

KINAX WT 707 Transmitter for angular position

KINAX WT 707 Transmitter for angular position Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact

More information

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor GmbH Postal address: House address Fon (+49) 0 22 42-870-0 Postbox 26 Löhestr. 7 Fax (+49) 0 22 42-870-20 http: // www.tematec.de 5759 Hennef 577 Hennef e-mail: team@tematec.de Data Sheet Page /5 Intelligent

More information

Liquid Level Switches

Liquid Level Switches Liquid Level Switches According to the Tuning Fork Principle measuring monitoring analysing N Repeatability: ± mm pmax: 45 bar tmax: 30 C, 50 C (for CIP process) Connections: Pipe screw joints, NPT, Flange,

More information

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid.

Edition March 2011 With publication of this catalogue all former printed general catalogues about RECHNER sensors are invalid. SHORTFORM CATALOGUE Registration No.: 1327-01 Testing laboratory accredited according to DIN EN 001 Reg.-No. DAT-P-08/9-00 For all transactions, the newest version of the General Conditions of Sale and

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Direction Transmitter First Class analogue output x0.1xx THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021514/03/09 Wind Direction Transmitter First Class analogue output 4.3150.x0.1xx ADOLF THIES GmbH

More information

Rudder or propeller angular position transmitter KINAX WT720

Rudder or propeller angular position transmitter KINAX WT720 Description The is a robust, absolute angular position transmitter, which is particularly suitable for use in marine applications such as the detection of rudder or propeller positions. In contrast to

More information

Magnetic Inductive Flowmeter

Magnetic Inductive Flowmeter Magnetic Inductive Flowmeter for conductivity liquids measuring monitoring analysing Measuring range: up to 10 m/s Accuracy: ±1.5% of reading ±0.5% full scale pmax: PN40 tmax: -40 +150 C Connection: flange

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

Inductive BEROs. 5/2 Summary of ranges. 5/6 Introduction. 5/20 Operating distance 0.6 mm. 5/20 Operating distance 0.8 mm. 5/22 Operating distance 1 mm

Inductive BEROs. 5/2 Summary of ranges. 5/6 Introduction. 5/20 Operating distance 0.6 mm. 5/20 Operating distance 0.8 mm. 5/22 Operating distance 1 mm /2 Summary of ranges /6 Introduction /20 Operating distance 0.6 mm /20 Operating distance 0.8 mm /22 Operating distance 1 mm /24 Operating distance 1. mm /28 Operating distance 2 mm /34 Operating distance

More information

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis

AS-1250FE Datasheet Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis Dynamic Signal Acquisition Front-End for Rotating Machinery Monitoring and Analysis HIGH PERFORMANCE ACQUISITION The AS-1250FE is a high performance, compact and flexible data acquisition hardware platform

More information

Wind Transmitter First Class

Wind Transmitter First Class THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for Use 021310/07/06 Wind Transmitter First Class 4.3350.00.000 4.3350.10.000 ADOLF THIES GmbH & Co. KG Hauptstraße

More information

Electrical Temperature Measurement

Electrical Temperature Measurement Electrical Temperature Measurement Resistance Thermometers Model TR10-B, for Additional Thermowell Applications Machinery, plant and tank construction Energy and power plant technology Chemical industry

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

SRS SEALED ROTARY SENSORS

SRS SEALED ROTARY SENSORS SRS SEALED ROTARY SENSORS Innovation In Motion INNOVATION IN MOTION Penny+Giles SRS280 sealed rotary sensors and SRS880 submersible rotary sensors have been specially developed to provide maximum performance

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-60 kg/h 0-60 000 kg/h water Accuracy: ±0,15 of reading ±zero-point stability pmax: PN40 tmax: -40 +180 C Connection:

More information

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases

BGN. All Metal Variable Area Flowmeter and Counter. for liquids and gases All Metal Variable Area Flowmeter and Counter for liquids and gases monitoring analysing BGN Measuring range: 0.5-5.0... 13000-130000 l/h water 0.015-0.15... 240-2400 m³/h air (20 C, 1.013 bar) Accuracy

More information

Limit switch attachments DAPZ

Limit switch attachments DAPZ Type codes DAPZ SB M 250AC DR AR Type DAPZ Limit switch attachment Specification SB Sensor box Measuring principle I M Inductive Electrical, micro switch Operating voltage 25DC 30DC 250AC 8 V DC 30 V DC

More information

Coriolis Massflowmeter

Coriolis Massflowmeter Coriolis Massflowmeter for liquids and gas measuring monitoring analysing Measuring range: 0-0.8 kg / h 0-65 000 kg / h water Accuracy: ± 0.1 of reading ±zero-point stability (liquids) pmax: PN40 tmax:

More information

Relative pressure transmitter type 522 for shipbuilding

Relative pressure transmitter type 522 for shipbuilding Relative pressure transmitter type 522 for shipbuilding Pressure range 0... 2.5 1000 bar The compact type 522 pressure transmitter for shipbuilding is based upon the Huba Control developed thick film technology

More information

Mineral-insulated resistance thermometers to EN

Mineral-insulated resistance thermometers to EN Data Sheet 90.2221 Page 1/6 Mineral-insulated resistance thermometers to EN 60 751 for temperatures from -50 (-200) to +600 C flexible sheath with shock-protected sensor as single or twin resistance thermometer

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution Features Robust, compact housing Two bearings with large distance, one at each end High shaft load up to 450 N Shock resistant up to 250 g Shaft insulation up to 2.8 kv Highest operating speed 10000 rpm

More information

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15...

Measuring range: l/h water m³/h air (20 C, bar) Connection: Flange DN 15... Full Metal Variable Area Flow Meter and Counter for Liquids and Gases monitoring analysing BGN Special versions up to 600 bar O Nominal diameter up to DN 150 S2 Measuring range: 0.5-5.0... 13000-130000

More information

Differential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3

Differential-Hall-Effect based Sensors Ex ia for Detection of Speed and Direction of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1DD3 / A5S1DS3 A5S1 ifferential-hall-effect based Sensors Ex ia for etection of Speed and irection of Rotation in Hazardous Areas Zone 0 or 1 Series A5S1 Overall View A5S1 sensors the best choice for demanding applications

More information

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications.

Tension/compression force transducer. With thin film technology up to 100 kn. Models F2301, F23C1, F23S1. Force. Applications. Force Tension/compression force transducer With thin film technology up to 100 kn Models F2301, F23C1, F23S1 tecsis data sheet FO 51.17 Applications Crane systems and hoists Industrial weighing technology

More information

Differential-Hall-Effect based Sensors for Detection of Speed and Direction of Rotation with two phase-shifted speed signals Series A5S0DD4 / A5S0DS4

Differential-Hall-Effect based Sensors for Detection of Speed and Direction of Rotation with two phase-shifted speed signals Series A5S0DD4 / A5S0DS4 A5S0 ifferential-hall-effect based Sensors for etection of Speed and irection of Rotation with two phase-shifted speed signals Series A5S0 Overall View A5S0 sensors the best choice for demanding applications

More information

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched

More information

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Target disk flowmeters Series DP Metallic flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions

More information

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting Electrical Temperature Measurement Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting WIKA Data Sheet TE 12.03

More information

Float switch For industrial applications, plastic version Model RLS-2000

Float switch For industrial applications, plastic version Model RLS-2000 Level measurement Float switch For industrial applications, plastic version Model RLS-2000 WIKA data sheet LM 50.04 Applications Level measurement of liquids in machine building Control and monitoring

More information

Coriolis Mass Flow Meter Model TM

Coriolis Mass Flow Meter Model TM Coriolis Mass Flow Meter for liquids and gas measuring monitoring analysing TM S5 Measuring range: 0-0.8 kg / h 0-65000 kg / h water Accuracy: ± 0.1 of reading ± zero-point stability (liquids) p max :

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex Data Sheet 10/-8.54 EN Level 0: Information FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex HART programmable, Pt 100 (RTD), thermocouples, electrical isolation Resistance thermometer (2,

More information

ELECTRONIC Counter TYPE AG5xEZD, AG5xEZ and AG4xEZD with Reed Sensors or Wiegand Sensors EZ / EZD. Operating Instructions

ELECTRONIC Counter TYPE AG5xEZD, AG5xEZ and AG4xEZD with Reed Sensors or Wiegand Sensors EZ / EZD. Operating Instructions ELECTRONIC Counter TYPE AG5xEZD, AG5xEZ and AG4xEZD with Reed Sensors or Wiegand Sensors EZ / EZD Operating Instructions Please read and keep the operating instructions. Bopp & Reuther Messtechnik GmbH

More information

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10

Technical data Model F1301 F13C1 ATEX/IECEX 2) F13C1 (Option) Nominal load F nom 10 / 20 / 30 / 50 / 100 / 200 kn 10 / 20 / 30 / 50 / 100 / 200 kn 10 Compression force transducer with Thin-film sensor Accuracy: 1 % Output signal: 4...20 ma; 2-wire, 0...10 VDC; 3-wire Optional Optional ATEX/IECEX II 2G Ex ib IIC T4/T3 for SIL3-Applications with 2-channel

More information

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web: -

DB 12 B. Double Sheet Testing Unit. Phone: Fax: Web:  - DB 12 B Double Sheet Testing Unit GB 03-08/08 50104956 Table of contents 1 General information... 2 1.1 Explanation of symbols... 2 1.2 Declaration of conformity... 2 2 Safety notices... 3 2.1 Safety standards...

More information