A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters

Size: px
Start display at page:

Download "A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters"

Transcription

1 THIS DRAWING IS PROPERTY OF AND PROPRIETARY TO EMERSON. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED NOR DISCLOSED TO ANYONE EXCEPT THOSE REQUIRING ITS USE FOR EMERSON AUTHORIZED PURPOSES. THIS DOCUMENT SHALL BE DESTROYED OR RETURNED TO EMERSON WHEN NO LONGER REQUIRED FOR THOSE PURPOSES. A9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters REV ECO NO. 0 Initial Release 6-Oct-07 E76 -DEC-07 Entity Parameters Connection Power In Power Out Sensor Out* Sensor In Terminals Power and Ground Bottom Plug S+ & S- / S+ & S- SIG / SIG & COM Marking Parameters Ui = 8 V Ui = 8 V Uo = 7.65 V Uo = 7.65 V Uo = 5. V Uo = 5. V Uo = 7. V Uo = 7. V Ii = 0 ma Ii = 70 ma Io = 06 ma Io = 06 ma Io = 7 ma Io = 7 ma Io = 9. ma Io = 9. ma Pi = 0.8 W Pi =.9 W Po = 8 mw Po = 8 mw Po = 0.8 W Po = 0.8 W Po = 55 mw Po = 55 mw Ci = 0 nf Ci = 0 nf Co = 9.8 µf Co = 85 µf Co = 75 nf Co = 58 nf Co =. µf Co = 00 µf Li = 80 µh Li = 80 µh Lo =. mh Lo = 7. mh Lo =. mh Lo = 5 mh Lo =. mh Lo = 9.5 mh * Entity parameters for sensor out S+ / S- & S+ / S- reflect total combined limitations for both channels. An appropriate shall be used to power the Emerson Transmitter. Conditions of Safe Use A9000Px shall be installed inside of an enclosure with a minimum IP rating of IP6. Field wiring using multiconductor cable shall either have each conductor enclosed in grounded metal shield or each conductor have a minimum of 0.5mm (0.0") insulation thickness. If an earth connection is made inside the transmitter housing, it should be made through the same enclosure entry as the external sensors. Model A9000PA: CSA-c/us 7CA7006 Class I, Div., Groups A, B, C & D, T; Class II, Div., Groups E, F & G; Class I, Zone 0, A/ SIRA/ATEX 7ATEXX 058 II G IECEx CSA 7.008X Model A9000PS: CSA-c/us 7CA7006 Class I, Div., Groups C & D, T; Class I, Div., Groups A, B, C & D T; Class I, Zone 0, A/; Class I, Zone, A/ SIRA/ATEX 7ATEXX 058 II G SIRA/ATEX 7ATEX75X II G IECEx CSA 7.008X Ta: -0 C to +85 C Emerson 85 Innovation Drive Knoxville, TN 79 USA Agency approved drawing. No changes without prior agency approval. MATERIAL: FINISH: ARTWORK FILENAME/: UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES TOLERANCES DECIMALS:.X ±.00.XX ±.00.XXX ±.00 FRACTIONS: ± / ANGULAR: FINISH: ± 0-0' DO NOT THIS DRAWING DESIGNED BY: DRAWN BY: For Reference Only LAST REVISED BY: RESP. ENGINEER MANUFACTURING ENG. DOCUMENT CONTROL J. Clemons 0-AUG-07 J. Clemons 0-AUG-07 J. Clemons -DEC-07 J. Baldwin 0-Aug-07 TITLE FIRST USED MODEL NO. A9000X A9000Px Installation Drawing OF 5

2 A9000Px Power/Signal Adapter for Accel Input to the AMS 90 Low Power Accel (5 mv/g) Sensor Sensors Sensor with Temperature Terminal = Both Red Wires Terminal = Red Wire Terminal = Red Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = White Wire Terminal = Green Wire Terminal = Both Black Wires Terminal = Both Black Wires Terminal = Black Wire = Both Cable s = Both Cable s = Cable 5 mv/g 5 mv/g Sensors are mounted to equipment being monitored. A9000PA or A9000PS-A S+ will be tied to Earth ground if Barrier is Sig Sig S- S- S+ 0 OF 5

3 Sensor S+ = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) A9000PS-A Power/Signal Adapter for Accel Input to the AMS 90 Powered ICP Accel (00 mv/g) Sensors S + = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) From A9000Px to AMS 90 Sig to Term Block Terminal = Gray Wire Sig to Term Block Terminal = Blue Wire to Term Block Terminal = Black Wire S+ Sig Sig S- S- S+ will be tied to Earth ground if Barrier is 00 mv/g 00 mv/g Sensors are mounted to equipment being monitored. 0 OF 5

4 A9000PS-V Power/Signal Adapter for Volts Input External Device with equivalent Entity Parameters Sensor S+ = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) Sensors S + = Red Wire (Power) S - = Blue Wire (Signal) = Green Wire (Chassis Ground) From A9000 to AMS 90 Sig to Term Block Terminal = Gray Wire Sig to Term Block Terminal = Blue Wire to Term Block Terminal = Black Wire S+ Sig Sig S- S- S+ Volt Input Volt Input will be tied to Earth ground if Barrier is External Device VOLTS input must maintain the entity parameters listed on Page. 0 OF 5

5 A9000Px Power Adapter for Emerson Transmitters Sensors are internal to the transmitter A9000PA or A9000PS-A S+ S- S- S+ Sig Sig will be tied to Earth ground if Barrier is 0 5 OF 5

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT

More information

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes

More information

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744

More information

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461 October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14

More information

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation

More information

ATEX Installation Drawings and Instructions

ATEX Installation Drawings and Instructions Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer

More information

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter Description RotaMass 3 Series Coriolis Mass Flow Meter; - Integral Transmitter, Model RCCx; - Remote Converter, Model RCCF31; - Remote Converter, Model RCCR31; - Remote Detector Model RCCS3xxxx The Coriolis

More information

Certificate of Conformity

Certificate of Conformity Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:

More information

Certificate of Conformity

Certificate of Conformity Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated;

More information

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Emerson (Appleton Group ATX)

Emerson (Appleton Group ATX) These assemblies are available in AC-powered and DC-powered versions. They have space to land 48 or 96 CHARM I/O depending on the model chosen. The field I/O can be specified as either IS or NON-IS I/O.

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing A5E00455287 system in total "No revision to drawing without prior Approval by FM Approvals!" PLC PC Non hazardous area PROFIBUS DP RS 485-IS Coupler PROFIBUS RS 485-IS

More information

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional

More information

Product manual wire programmable RTD transmitter

Product manual wire programmable RTD transmitter Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001

More information

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer

More information

Product Manual wire HART transmitter

Product Manual wire HART transmitter Product Manual 6335 2wire HART transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 6335V111UK From serial no.: 150951186 6 Product

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70163240 (166720) Issued to: WIKA Alexander Wiegand SE & Co. KG Alexander-Wiegand-Str 30 Klingenberg, Bayern 63911 GERMANY Attention: Harald Gollas The products listed

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions

More information

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...

Introduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information... Technical Information FLXA202 2-Wire Analyzer Selection Guide for Intrinsic Safety-type Associated Apparatus TM Contents Introduction...2 1. Intrinsic safe system...3 2. How to select sensors...5 3. How

More information

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters

More information

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions

More information

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Installation Instructions P/N MMI-20011709, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters Note: For hazardous installations in Europe, refer to standard EN

More information

General Specifications

General Specifications General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless

More information

General Specifications

General Specifications General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

INTRINSICALLY SAFE DUPLEXER

INTRINSICALLY SAFE DUPLEXER INTRINSICALLY SAFE DUPLEXER MADE IN THE U.S.A. DESCRIPTION The Intrinsically Safe Duplexer, ISD, is a low cost SCADA ready intrinsically safe pump controller designed to perform level control for duplex

More information

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class:

Thie. Automation Products Rev. Chang Date Name Supersedes Dwg. : Part Class: Page: 1 of 3 - - 2003 Date Name Name 27.03.03 Thiem. Title FM/CSA-Control-Document Appr. / 5 08.07.11 Thie. Std. 4 07.10.09 Lasa. 3 26.06.06 Thie. Drwg.-No. (Part-No.) 2 22.05.06 Thie. 901265 1 27.03.

More information

IECEx Certificate of Conformity Annexe

IECEx Certificate of Conformity Annexe for Certificate No.: IECEx TSA 13.0023X Issue No.: 0 Description: The Measuring Gauge of type series SMALL * / / / / / / / / / / * / * is an intrinsically safe supplied apparatus providing different electronic

More information

Product Manual wire HART transmitter

Product Manual wire HART transmitter Product Manual 6337 2wire HART transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 6337V103UK From serial no.: 150950564 6 Product

More information

R88000 T (including ATEX)

R88000 T (including ATEX) INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:

More information

1-830 SERIES DISPLACEMENT TRANSMITTER

1-830 SERIES DISPLACEMENT TRANSMITTER 1-830 SERIES DISPLACEMENT TRANSMITTER Operation & Maintenance Manual 746 Arrow Grand Circle Covina, CA 91722 United States of America Tel: (626) 938-0200 Fax: (626) 938-0202 Internet: http://www.cecvp.com

More information

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol

MCR-FL-TS-LP-I-EX SIL IEC Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol SIL IEC 6 508 Programmable Intrinsically Safe Loop-Powered Temperature Measuring Transducer With HART Protocol Data Sheet 0068_en_03 PHOENIX CONTACT 0-07-09 Description Temperature FL ϑ Universal PC programmable

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse

More information

Level Lance Model 5100

Level Lance Model 5100 Sales Manual Section 100 Product Specification Model 5100 Level Lance Model 5100 GENERAL DESCRIPTION The Robertshaw Model 5100 Level-Lance is a microprocessor based, advanced technology On-Off level detection

More information

SET Installation and Operating Instructions. Level switch for two sensors

SET Installation and Operating Instructions. Level switch for two sensors Labkotec Oy Myllyhaantie 6 FI-33960 PIRKKALA FINLAND Tel: + 358 29 006 260 Fax: + 358 29 006 1260 20.2.2013 Internet: www.labkotec.fi 1/14 SET-2000 Level switch for two sensors Copyright 2013 Labkotec

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5. GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater

D1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Model Number Matrix: Model 150Ex 250Ex Power Distribution Cabinet 1 (combined) 1 (combined) Control Cabinet 500Ex 1 1 750Ex 1 1 1000Ex 1 1 1250Ex 1 1 1500Ex 1 1 The system model number reflects the total

More information

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks

technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks Megablocks are DIN-rail mounted passive hubs for FOUNDATION fieldbus networks. They connect several field devices

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and

More information

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD

ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD Product Information Package PIP-CW ISProx Jul., 007 ControlWave ISProx Board ControlWave INTRINSICALLY SAFE PROXIMITY SENSOR INTF. BOARD For ControlWave EFM/GFC/GFC Correctors Remote Automation Solutions

More information

Single-Channel Safety Barriers Series 9001

Single-Channel Safety Barriers Series 9001 Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving

More information

STT 3000 Smart Temperature Transmitter Series STT170 Specifications

STT 3000 Smart Temperature Transmitter Series STT170 Specifications STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable

More information

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier

ATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer

More information

megablock series passive hubs for fieldbus networks

megablock series passive hubs for fieldbus networks passive hubs for fieldbus networks Relcom megablock series Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and

More information

Product manual wire HART 7 temperature transmitter

Product manual wire HART 7 temperature transmitter Product manual 7 2-wire HART 7 temperature transmitter PERFORMANCE MADE SMARTER PENDING PENDING PENDING TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 7V101-UK

More information

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents KENCO ENGINEERING COMPANY P.O. BOX 470426, TULSA, OK 74147-0426 PHONE: (918) 663-4406 FAX: (918) 663-4480 http://www.kenco-eng.com e-mail: info@kenco-eng.com KENCO Loop Powered Magnetostrictive Transmitter

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

protim-r Module

protim-r Module 200200 protim-r Module Bently Nevada* Asset Condition Monitoring Description The 200200 dual-input protim-r (DIN rail mount) provides 2 channels of measurement. All acceleration-to-velocity (A-V) channels

More information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval

More information

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams

Instruction. MI October I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams Instruction MI 019-175 October 2000 I/A Series Models 83.-D and -T Vortex Flowmeter Intrinsic Safety Connection Diagrams MI 019-175 October 2000 Intrinsically Safe Connection Diagrams If your Model 83.-D/-T

More information

Cyclops User s Manual

Cyclops User s Manual Cyclops User s Manual Revision 5.x.x March 14, 2017 Contents Background... 1 Interface... 1 Normal Operation... 1 Controller Input Type... 1 Communication... 2 Sensitivity... 3 Operating Modes... 3 Normal...

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL

More information

Rosemount 3101, 3102, and 3105

Rosemount 3101, 3102, and 3105 Product Data Sheet February 2013 00813-0100-4840, Rev DA Rosemount 3101, 3102, and 3105 Ultrasonic Liquid Level Transmitters Non-contacting measurement with no moving parts Integral LCD and buttons as

More information

This document outlines how to install the IP20 protection cover on a GE Universal Relay (UR) device to yield an IP20 safety rating.

This document outlines how to install the IP20 protection cover on a GE Universal Relay (UR) device to yield an IP20 safety rating. GE Grid Solutions UR Family IP20 Cover Installation Instructions GE Publication Number: GEK-119546C GE Part Number: 1601-9216-A4 Copyright 2016 GE Multilin Inc. This document outlines how to install the

More information

Electrodynamic Velocity Sensor

Electrodynamic Velocity Sensor PR9268 Specifications Sheet July 2018 Electrodynamic Velocity Sensor Mechanical velocity sensor for absolute vibration measurement of critical turbomachinery applications such as steam, gas and hydro turbines,

More information

Loop Powered Indicator

Loop Powered Indicator Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

2-wire level transmitter

2-wire level transmitter Badger Meter Europa GmbH 2-wire level transmitter Model L2xx INSTALLATION AND OPERATION MANUAL July 2002 Version UF-L2xx-07/02-e Contents Contents Page 1. Installation 1 1.1 Mounting the instrument 1 1.2

More information

Fisher LCP100 Local Control Panel

Fisher LCP100 Local Control Panel Instruction Manual Local Control Panel Fisher Local Control Panel Contents Introduction... Scope of Manual... Description... Specifications... Educational Services... Installation... 5 Hazardous Area Classifications

More information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/ > 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

protim-r Module

protim-r Module 200200 protim-r Module Description The 200200 dual-input protim-r (DIN Rail mount) provides two channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer

More information

JM Enclosure Dimensions (in mm)

JM Enclosure Dimensions (in mm) ub #0revB process networking solutions Junction Module (JM ) Enclosure with: FOUNDATION Fieldbus Input/Output Module (JMM9 ) These I/O Modules are designed to function as FOUNDATION Fieldbus nodes with

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere

More information

Universal Intelligent 2-wire DIN Rail Transmitters

Universal Intelligent 2-wire DIN Rail Transmitters Universal Intelligent 2-wire DIN Rail Transmitters IPAQ-L is a universal and intelligent 2-wire DIN rail transmitter for temperature and other measurement applications. IPAQ-LX is the Intrinsic Safe version

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

SELECTION GUIDE. Interfaces galvanic insulation.

SELECTION GUIDE. Interfaces galvanic insulation. SELECTION GUIDE Interfaces galvanic insulation 1. and notions of intrinsic safety 1. 4 2. Notions of intrinsic safety 7 2. 1. Mechanical properties 12 2. Certifications 12 3. Dimensions 12 3. Selection

More information

Temperature Input Module for Zone 1 Series 9482/32

Temperature Input Module for Zone 1 Series 9482/32 www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >

More information

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO

QN5O, QXBO, QNBO, QX7O, QN7O, QXCO, QNCO QUARTZ with -0 ma Position Transmitter or Potentiometer (QXO, QNO, QXBO, QNBO, QXO, QNO, QXO, QNO ) SERIES Thru-Bolt Mounting Pub # 00rev Installation & Adjusting Instructions. Attach mounting plate to

More information

Rosemount 148 Temperature Transmitter

Rosemount 148 Temperature Transmitter Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement

More information

Ultra Resolution ER RS-485 Transmitter (Model MS2801E) Operator s Manual

Ultra Resolution ER RS-485 Transmitter (Model MS2801E) Operator s Manual Ultra Resolution ER RS-485 Transmitter (Model MS2801E) Operator s Manual Metal Samples A Division of Alabama Specialty Products, Inc. 152 Metal Samples Rd., Munford, AL 36268 Phone: (256) 358-4202 Fax:

More information

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter

More information

Certificate of Conformity

Certificate of Conformity Applicant: Trolex Limited Newby Road, Hazel Grove Stockport SK7 5DY UK Electrical Apparatus: Programmable Sensor Controller Type TX9042 Type of Protection: Ex ia Marking Code: Trolex Ltd TX9042 Programmable

More information

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22 www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit

More information

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.

SEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO. INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3

More information

1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input

1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input 1701/25 FieldMonitor Seismic Input Monitor for Velocity and Acceleration Input Bently Nevada Asset Condition Monitoring Description The 1701/25 FieldMonitor Seismic Input Monitor is a 2-channel device

More information

SCS-400. Sealed Parcel Delivery System. Installation Manual

SCS-400. Sealed Parcel Delivery System. Installation Manual Sealed Parcel Delivery System Contents 1. Introduction... 1 2. Pre Installation... 1 2.1. General... 1 2.2. Exd... 2 2.3. Intrinsic Safe... 3 2.4. SCS-400... 4 2.5. API-400 Sensor... 4 2.6. BVS-100 Sensor...

More information

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology

Level Plus. Magnetostrictive Liquid-Level Transmitters with Temposonics Technology Level Plus Magnetostrictive Liquid-Level Transmitters with Temposonics Technology BRIEF OPERATION MANUAL FOR SAFE USE M-Series Model MG Digital Transmitter UNITED STATES GENERAL: Tel: +1-919-677-0100

More information

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD User manual Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD Contents Precautions Intended use General 1 Specification 3

More information

Positioner with HART Communication Type 3780

Positioner with HART Communication Type 3780 Positioner with HART Communication Type 780 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Supplied with an electric input signal from to 20 ma Travels

More information

Binary Output without Power Supply Series 9176

Binary Output without Power Supply Series 9176 Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output

More information

FRYCORDER Power Cord Burn-in Generator

FRYCORDER Power Cord Burn-in Generator FRYCORDER Power Cord Burn-in Generator Made in USA FRYCORDER Power Cord Burn-in Generator Copyrights & Trademarks Copyright Hagerman Audio Labs 0. All rights reserved. No part of this document may be photocopied,

More information

ESSENTIAL INSTRUCTIONS Read this page before proceeding!

ESSENTIAL INSTRUCTIONS Read this page before proceeding! Instruction Sheet LIQ_MAN_ABR_/Rev.G January 2015 Remote Controlled HART SMART Two-Wire Conductivity Transmitter ESSENTIAL INSTRUCTIONS Read this page before proceeding! Your purchase from Rosemount Analytical,

More information

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation

More information

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System

More information

General Specifications

General Specifications General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus

More information