IECEx Certificate of Conformity
|
|
- Corey Cook
- 6 years ago
- Views:
Transcription
1 Model Number Matrix: Model 150Ex 250Ex Power Distribution Cabinet 1 (combined) 1 (combined) Control Cabinet 500Ex Ex Ex Ex Ex 1 1 The system model number reflects the total amount of water treated in cubic meters per hour. Page 1 of 11
2 Manufacturers Documents: Title: No.: Rev. Level: Date: Ex CERT CONTROL MANUAL DOC G A CC ASSY, MRX 500/750 Ex SCHED EXTERIOR CABINET ASSEMBLY (5 pages) PDC ASSY, MRX 500/750 Ex SCHED EXTERNAL LAYOUT (4 pages) CPC ASSY, MRX 150/250 Ex SCHED EXTERNAL LAYOUT (5 pages) WD, MRX CPC 150/250 Ex SCHED INCOMMING POWER (10 pages) WD, MRX CC 500/750 SCHED Ex INCOMMING POWER (8 pages) WD, MRX PDC 500/750 SCHED EX INCOMMING POWER (5 pages) C C C C B A LABEL, LAMICOID Ex G A WD, OVERVIEW 150/250 Ex SCHED (3 pages) WD, MRX PDC Ex SCHED INCOMING POWER (7 pages) PDC ASSY, MRX Ex SCHE EXTERNAL LAYOUT (4 pages) WD,MRC CC Ex SCHED INCOMMING POWER (11 pages) CC ASSY, MRX Ex SCHE EXTERIOR CABINET ASSEMBLY CONTROL, DRAWING 150/250 CPC (2 pages) G A B B B B A CONTROL, DRAWING 500/750 PDC A CONTROL, DRAWING 500/750 CC (2 pages) CONTROL, DRAWING PDC (2 pages) CONTROL, DRAWING CC (2 pages) LABEL, COMPONENT UNIVERSAL (Page 5) A A A G M Page 2 of 11
3 Major components/devices used within the Trojan Marinex Power Distribution and Control Cabinets / Item / Item / Item 98 IS Barrier PWR Rail 3a Item 98 IS Barrier Item 3) 3b Item 98 IS Barrier Item 3) P+F KFD2-EB2 TÜV 00 ATEX 1618X Supplement 1 BAS00ATEX7240 Issue 9 GM International D1020D IECEx BVS X II 3G Ex na nc IIC T4 Used wholly within the power/control cabinets in the unclassified area. This does not drive any devices in the hazardous area. Universal Power Rail P+F UPR-03 NA NA Provides power to IS barriers in cabinets in unclassified location. IS Barrier P+F KFD2-CD2-Ex2 IECEx BAS [Zone 0] [Ex ia] IIC [Ex ia] I [Ex iad] -20 C Ta +60 C DMT 01 ATEX E 042 X Supplement 10 MTL MTL5549 IECEx ITA X issue No.:1 Baseefa07ATEX0215/3 Ex na [ia Ga] IIC T4 Gc II 3 (1) G Ex na [ia Ga] IIC T4 Gc -20 C Ta +60 C Page 3 of 11
4 3d Item 98 IS Barrier Item 3) / Item 96 4a Item 96 IS Barrier Item 4) 4b Item 96 IS Barrier Item 4) 4c Item 96 IS Barrier Item 4) R.Stahl 9165/ s IECEx BVS X issue No.:2 DMT 03 ATEX E 012 X IS Barrier P+F KFD2-STC4-Ex2 IECEx BAS BAS99ATEX7025/10 GM International D1014D IECEx BVS X DMT 01 ATEX E 042 X Supplement 10 MTL 5544S IECEx BAS issue No.:5 Baseefa09ATEX0156/5 R. Stahl 9160/ s IECEx BVS Issue 2 DMT 03 ATEX E 010 X II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc Um = 253 V Uo = 25.6V Io = 96 ma Po = 605 mw Co = 103 nf (IIC) Lo = 1.9 mh (IIC) Ci = negligible Li = negligible II (1)GD [Ex ia] IIC Ex na [ia Ga] IIC T4 Gc II 3 (1) G Ex na [ia Ga] IIC T4 Gc Ex na [ia Ga] IIC T4 Gc Page 4 of 11
5 / Item 95, 84 IS Barrier (Switch Amplifier) P+F KFD2-SRA-Ex4 IECEx TUN issue No.:2 ZELM 99 ATEX 0009 Supplement 4 Um = 40V Uo = 10V Io = 14mA Po = 35mW 5a Item 95, 84 IS Barrier Item 5) GM International D1032Q IECEx BVS X DMT 01 ATEX E 042 X Supplement 10 Co = 3 uf (IIC) Lo = 180 mh (IIC) Uo/Voc = 9.6 Io/Isc = 10 ma Po/Po = 24 mw 4 Ch, Switch/Proximity Detector Repeater. 5b Item 95, 84 IS Barrier Item 5) MTL MTL5510 IECEx ITA X issue No.:1 Baseefa07ATEX0215/3 Co/Ca = uf (IIC) Lo/La = 379 mh (IIC) Lo/Ro = 1530 uh/ohm (IIC) -20 C Ta +60 C Uo=10.5V Io=14mA Po=37mW Um = 253V rms or dc Page 5 of 11
6 5c Item 95, 84 IS Barrier Item 5) /Item 94 R.Stahl 9170/ s IECEx BVS X issue No.:2 DMT 02 ATEX E 195 X supplement 4 IS Barrier GM International D1061S DNV 04 ATEX 0199 Rev 1 II 3 (1) G Ex nac ncc [ia] IIC T4 (Single channels) Um = 253 V Uo=9.6V Io=10mA Po=24mW Co = 3.6 uf max Lo = 350 mh max Ci = 2.42 nf Li = negligable II (I) G [Ex ia Ga) IIC Input: Um = 250V Ui = 30VDC Ii = 282 ma Output: Uo = 3.7V Io = 225 ma Po = 206 mw Lo = 0.7 mh (IIC) Co = 100 uf (IIC) Lo/Ro = 173 uh/ohm (IIC) RS-485 repeater Page 6 of 11
7 7 Item 85, 97 IS Barrier R.Stahl 9175/ IECEx BVS X issue No. 1 II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc 7a Item 85, 97 IS Barrier Item 7) DMT 03 ATEX E 043 X Issue 3 MTL Instruments MTL5521 IECEx BAS issue No.:6 Baseefa07ATEX0212 supplement 5 Uo = 27.6V Io = 50mA (ib) Po = 760 mw Ci = 1.1 nf Li = negligible Lo = 1.2 mh Co = 85 nf Um = 253V Uo = 25V Io = 147mA Po = 920 mw Ci = 0 Li = 0 Co = 0.11uF (IIC) Lo = 1.4mH (IIC) l/r = 40 uh/ohm (IIC) Page 7 of 11
8 7b Item 85, 97 IS Barrier Item 7) GM International D1042Q IECEx BVS X DMT 01 ATEX E 042 X Supplement 10 Terminals 13-14, 15-16, 9-10, (single chanel) Uo = 23.6V Io = 88.2 ma Po = 519mW Quad channel DIN Rail Digital Output Modules/ Bus Powered 7c / Item 85, 97 IS Barrier P+F KFD2-SL2-Ex2 IECEx TUN issue No.:1 ZELM 00ATEX0024 Issue 3 Co = 0.13 uf (IIC) Lo = 4.5 mh (IIC) Lo/Ro = 68.6 uh/ω (IIC) Um = 60V Uo = 28V Io = 110mA Po = 770 mw Ci = negligible Li = negligible / 37, 23, 38 Terminal Block Phoenix PTTB 2,5 BU ECEx PTB U issue No.:2 PTB 09ATEX1111U Co = 83nF (IIC) Lo = 3mH (IIC) II 2 G Ex eb IIC Blue DIN rail mounted terminal block, mm2 wire, 20.5 amps, 440 V. Page 8 of 11
9 / 30, 24 Terminal Block (Earth) Phoenix Phoenix PTTB 2,5-PE ECEx PTB U issue No.:2 PTB 09ATEX1111U Ex eb IIC Green terminal block, mm2 wire. Special Conditions of Safe Use/Schedule of Limitations applicable to this equipment: Device Special Condition of Safe Use 3b, 5b MTL5549 Input: Terminals 8,9,11,12,13 & 14: The circuit connected to the non-hazardous area terminals are designed to e supplied from a DC supply voltage up to 35 volts. Output: Each channel must be considered a separate intrinsically safe circuit. MTL5510 Input: Terminals 7 to 14: The circuit connected to the non-hazardous area terminals are designed to e supplied from a DC supply voltage up to 35 volts. Output: Each channel must be considered a separate intrinsically safe circuit. 3d Barriers are powered by a 24 volt power supply. Each channel was individually evaluated as an intrinsically safe circuit. The barrier is used in a cabinet in an unclassified location. 4 The Annex of the certificate has a table of special conditions of safe use for various models covered by the certificate. There are no SCoSU for model MTL Page 9 of 11
10 Device 5a, 7b GM International barrier Special Condition of Safe Use 5c The barriers are DIN rail mounted in an enclosure in a non-hazardous area. Spacings meet the minimums 3mm and 50 mm spacing requirements from IEC The barrier is used in a cabinet in an unclassified location. 7 For use in Zone 2 the binary output type 9175 has to be mounted inside an enclosure which is in accordance with IEC The barrier is used in a cabinet in an unclassified location. Page 10 of 11
11 Device 20, 21 Special Condition of Safe Use The terminal blocks were evaluated as part of the overall equipment. Page 11 of 11
INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationINSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D
D034S D034D INSTRUCTION MANUAL SIL 3 Switch/Proximity Detector Interface DINRail Models D034S, D034D D034 SIL 3 Switch / Proximity Detector Interface ISM0053 SIL Applications For Safety Related System
More informationDescription. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461
October 13, 2017 Annexe to: IECEx CML 15.0063X Issue 1 Applicant: Apparatus: Braun GmbH Isolating Amplifier D461 Description The Isolating Amplifier D461 is an intrinsic safety associated apparatus
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationD1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater
D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationD1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:
Characteristics: Front Panel and Features: Ordering Information: Model: D7 D7 General Description: The single and dual channel DIN Rail Temperature Signal Converter D7S and D7D accepts a low level dc signal
More informationINSTRUCTION & SAFETY MANUAL
D1044S - D1044D INSTRUCTION & SAFETY MANUAL - Digital Relay Output Loop / Bus Powered DIN-Rail Models D1044S, D1044D D1044 - - Digital Relay Output ISM000-10 General Description: The single and dual channel
More informationEmerson (Appleton Group ATX)
These assemblies are available in AC-powered and DC-powered versions. They have space to land 48 or 96 CHARM I/O depending on the model chosen. The field I/O can be specified as either IS or NON-IS I/O.
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationINTRINSIC SAFETY BARRIERS - ATEX
NTRNSC SAFETY BARRERS ATEX Characteristics: D General Description: The single and dual channel DN Rail Repeater Power Supply, DS and DD, provides a fully floating dc supply for energizing conventional
More informationD5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:
Characteristics: Front Panel and Features: 5 6 3 1 SIL 11 1 Ordering Information: Model: 1 channel channels D50 D50 SIL according to IEC 6150 for Tproof 5 years ( % of total SIF). Input from Zone 0 (Zone
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationMicro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc
IECEx Installation Instructions EB-20025744 Rev. AC December 2015 Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc 5700 IECEx Installation Instructions EB-20025744
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationSingle-Channel Safety Barriers Series 9001
Single-Channel Safety Barriers Series 9001 > Broad product range for all standard applications in the world of automation > Flexible and space saving single and dual channel versions available > Time saving
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationINSTRUCTION & SAFETY MANUAL
D0D D0Q INSTRUCTI & SAFETY MANUAL SIL Switch/Proximity Detector Repeater Transistor DINRail ls D0D, D0Q D0 SIL Switch / Proximity Detector Repeater Transistor ISM0009 Characteristics General Description:
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive acc. to EN 60947-5-6) Line fault transparency
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationD5072. SIL 2 Temperature Signal Converter, Multifunction, DIN-Rail and Termination Board, Models D5072S, D5072D. Characteristics: Technical Data:
Characteristics: Front Panel and Features: 5 6 3 1 SIL 11 1 Ordering Information: Model: 1 channel channels D50 SIL according to IEC61511 for Tproof3/yrs ( % / > % of total SIF), SFF.% PFDavg (1 year)
More informationIsolating Repeater Input Series 9163
> For 4-wire HART transmitters and voltage sources > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2 (IEC 61508) > High accuracy www.stahl.de
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationMicro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc
ATEX Installation Instructions EB-20025742 Rev. AC December 2015 Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc 5700 ATEX Installation
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationFieldbus Isolating Repeater Series 9185/11
www.stahl.de > For operation of the intrinsically safe Profibus DP (RS-485 IS to PNO standard) > Intrinsically safe fieldbus RS-422, RS-485 [Ex ib] IIC > Galvanic isolation between RS-422 / RS-485, RS-232,
More informationINSTRUCTION & SAFETY MANUAL
D0D D0Q INSTRUCTI & SAFETY MANUAL SIL /Proximity Detector Repeater Relay DINRail Models D0D, D0Q D0 SIL / Proximity Detector Repeater Relay ISM00 General Description: The /Proximity Detector Repeater type
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160
Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationAssembly. Front view. Switch Power Rail
Switch Amplifier Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) Dry contact or NAMUR input 2 passive transistor outputs (resistive) Application-specific outputs Line fault transparency
More informationIECEx Certificate of Conformity Annexe
for Certificate No.: IECEx TSA 13.0023X Issue No.: 0 Description: The Measuring Gauge of type series SMALL * / / / / / / / / / / * / * is an intrinsically safe supplied apparatus providing different electronic
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More information3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.
Ex i Isolators Temperature Transmitter without Output 0/4... 20 ma, with Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationAnnex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter
Description RotaMass 3 Series Coriolis Mass Flow Meter; - Integral Transmitter, Model RCCx; - Remote Converter, Model RCCF31; - Remote Converter, Model RCCR31; - Remote Detector Model RCCS3xxxx The Coriolis
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More information3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.
Ex i Isolators Temperature Transmitter with Output 0/4... 20 ma, without Limit Value Contact Field Circuit Ex i) One unit for nearly all temperature sensors indivdually configurable Intrinsically safe
More informationINSTRUCTION & SAFETY MANUAL
D0D D0Q INSTRUCTI & SAFETY MANUAL SIL /Proximity Detector Repeater Transistor DINRail Models D0D, D0Q D0 SIL / Proximity Detector Repeater Transistor ISM00 Characteristics General Description: The /Proximity
More informationCertificate of Conformity
Certificate Holder: ABB Automation Products GmbH Schillerstrasse 72 D-32425 Minden GERMANY Electrical Apparatus: Type of Protection: 2600T Pressure Transmitter Models 265../267../269.. Communication protocol:
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters
Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationAssembly. Front view. HiC2441. SL2 1b. Termination Board
SMART Universal Barrier HiC Features Assembly channel isolated barrier V DC supply (bus powered) Analog input, digital input, analog output, digital output No configuration required, device is selfadapting
More informationProduct manual wire programmable RTD transmitter
Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001
More informationD1072S - D1072D INSTRUCTION MANUAL. D SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor. Din-Rail Models D1072S, D1072D
D7S D7D INSTRUCTION MANUAL SIL Temperature Signal Converter, Duplicator, Adder/Subtractor DinRail Models D7S, D7D D7 SIL Temperature Signal Converter, Duplicator, Adder/Subtractor ISM0018 SIL Applications
More informationData Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)
Data Sheet KFD-UFC-EX1.D Supplied by.com Call us on +44 (0)118 916 940 Email info@47able.com Frequency Converter with Trip Values Features Assembly 1-channel isolated barrier 4 V DC supply (Power Rail)
More information3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/
3 Ex i Isolators Switching Repeater with Power Relay Intrinsically safe input [Ex ia] IIC Galvanic isolation between input, output and power supply Open-circuit / short-circuit monitoring and messaging
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationCertificate of Conformity
Applicant: Moore Industries International Inc. 16650 Schoenborn Street North Hills CA 91343-6196 U.S.A Electrical Apparatus: Fully Encapsulated PC-Programmable Temperature Transmitters (TRX: nonisolated;
More informationTwo-channel safety barriers Series 9002
Two-channel safety s Series 00 > Wide product range for all standard applications of the automation > Flexible and space-saving available in single and double channel versions > Time-saving installation
More informationmegablock series passive hubs for fieldbus networks
passive hubs for fieldbus networks Relcom megablock series Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and
More informationMODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT
Space-saving Two-wire Signal Conditioners B3-UNIT 2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe) Functions & Features Universal input: mv, V, T/C, RTD, resistance, potentiometer
More informationtechnical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks
technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks Megablocks are DIN-rail mounted passive hubs for FOUNDATION fieldbus networks. They connect several field devices
More informationAssembly. Front view. Power Rail
Thermometer Resistance Repeater Features Assembly 1-channel isolated barrier 24 V DC supply (Power Rail) RTD/resistance input Resistance output Accuracy 0.1 % Front view Removable terminals blue Function
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationAssembly. Front view. LED yellow: Relay output. LED red: LB/SC
Switch Amplifier Features Assembly -channel isolated barrier 30 V AC supply Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL acc. to IEC
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationSCS-400. Sealed Parcel Delivery System. Installation Manual
Sealed Parcel Delivery System Contents 1. Introduction... 1 2. Pre Installation... 1 2.1. General... 1 2.2. Exd... 2 2.3. Intrinsic Safe... 3 2.4. SCS-400... 4 2.5. API-400 Sensor... 4 2.6. BVS-100 Sensor...
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationIsolators A3/1.
Temperature Transmitter Series 9182 > One unit for nearly all temperature sensors indivdually configurable > Signal duplication possible > Galvanic isolation between input, output, power supply and configuration
More informationIsolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No
9165/16-11-10s 207909 Compact one- and two-channel Ex i output isolating repeater wire-breakage and short-circuit monitoring system, which can be disconnected and features a signalling contact can be used
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationMODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With
Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE
More informationINSTRUCTION & SAFETY MANUAL
D509S NSTRUCT & SAFETY MANUAL SL 3 Digital Output Driver, NE Loads, Bus Powered DN Rail and Termination Board, Model D509S D509 SL 3 Digital Output Driver, NE Loads, Bus Powered G.M. nternational SM0200
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationonlinecomponents.com
Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common
More informationCertification of EXPLOSION PROTECTED ELECTRICAL EQUIPMENT
Certificate of Conformity Certificate No: ANZEx 11.2009 Issue: 0 16 December 2011 Original Issue Applicant: Pepperl+Fuchs GmbH Lilienthalstrasse 200 68307 Mannheim GERMANY Electrical Equipment: Isolation
More informationR88000 T (including ATEX)
INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:
More informationTÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.
GmbH & Co. KG Page 1 of 5 Electrical data: Base devices for 6DR50**-*****-**** Motherboard L250 Power supply / control current 4-20 ma... series connection (terminals 6+ and 7/8) 2-wire circuit with Hart
More informationGeneral Specifications
General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationDigital Input Output Module for Zone 1 Series 9470/32
www.stahl.de > 16 can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8 can be used
More informationIntroduction Intrinsic safe system How to select sensors How to select safety barriers...6 Revision Information...
Technical Information FLXA202 2-Wire Analyzer Selection Guide for Intrinsic Safety-type Associated Apparatus TM Contents Introduction...2 1. Intrinsic safe system...3 2. How to select sensors...5 3. How
More informationISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES
ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES RoHS Compliant Registration No.: 1327-01 For all transactions, the newest version of the General Conditions of Sale and Delivery for Products and Services
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationA9000Px Power/Signal Adapter Installation Drawing for Emerson Transmitters
THIS DRAWING IS PROPERTY OF AND PROPRIETARY TO EMERSON. THIS DRAWING AND THE INFORMATION CONTAINED HEREIN SHALL NOT BE REPRODUCED NOR DISCLOSED TO ANYONE EXCEPT THOSE REQUIRING ITS USE FOR EMERSON AUTHORIZED
More informationSTT 3000 Smart Temperature Transmitter Series STT170 Specifications
STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable
More informationATEX Installation Instructions for Micro Motion CMF400 Sensors with Booster Amplifier
Installation Instructions P/N MMI-20010152, Rev. A June 2007 for Micro Motion CMF400 Sensors with Booster Amplifier For ATEX-approved sensor installations Note: For hazardous installations in Europe, refer
More informationUser Manual mantracourt.com
ALA5 2-Wire 4-20mA ATEX Load Cell Amplifier ICA5ATEX Strain Gauge or Load Cell Analogue Amplifier Mounted Inside an In-Line Stainless Steel Enclosure (ILEATEX) User Manual mantracourt.com Contents Chapter
More informationMACX MCR-EX-SL-RPSSI-I
Extract from the online catalog MACX MCR-EX-SL-RPSSI-I Order No.: 2865340 Ex-i repeater power supply and input isolation amplifier, HART. Sends fed or active 0/4-20 ma signals from the Ex area to a load
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: Certificate history: Issue No.
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationSOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS
SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval
More informationIntrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i
Intrinsically Safe Compact Controller CTR 210i Intrinsically Safe Bargraph Indicator BGI 210i DMT 02 ATEX E 148 2. Supplement also grahics display Revision 4 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.:
More information