technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks
|
|
- Jesse Logan Walters
- 6 years ago
- Views:
Transcription
1 technical datasheet technical datasheet Megablock Series passive hubs for fieldbus networks Megablocks are DIN-rail mounted passive hubs for FOUNDATION fieldbus networks. They connect several field devices to the network trunk cable and provide short circuit protection to the segment. Megablocks minimize hand wiring and allow individual devices to be added to and removed from the segment without disrupting network communication. A green power LED on each unit indicates whether at least 9V dc is present. Megablocks are available in two, four, eight, ten and twelve drop versions. Multiple Megablocks are easily wired to one another to allow larger segments to be constructed. The Megablock Terminator is easily wired to any Megablock to prevent signal reflection on the fieldbus segment. The Megablock Terminator is clearly marked for easy identification by field personnel. Megablocks are also available with an integral terminator making them ideal for a star or chickenfoot topology where several devices are connected at a single field junction box. Each Megablock has two dedicated connections for the fieldbus home run or trunk cable. Trunk connections are easily identified by their black connectors. Separate numbered connections are provided for each spur drop. Connections to the Megablock are made using pluggable screw terminal type connectors. This allows wire terminations to be made to the individual connectors which are then plugged into the Megablock. Devices can then be easily connected and disconnected during commissioning. After commissioning, retaining screws are tightened to secure each connector to the Megablock. SpurGuard is a device-port, short circuit protection technique that minimizes susceptibility to single points of failure, The Megablocks are available with built-in SpurGuard protectors that prevent a short circuit in any of the individual transmitters or spur cable runs from bringing the entire fieldbus segment down. A red LED near each spur connection indicates that a spur is shorted and is in overcurrent mode. Megablock hazardous area approvals permit installation in a variety of configurations in Zone or and Division or. Within Zone or Division Megablocks may be installed as part of non-sparking (non-arcing) or energy-limited (non-incendive) circuits. Additionally, SpurGuard versions have energy-limited spur connections even if the trunk is classified as 'non-sparking', when fed for example from an Fxx or FPS-I fieldbus power supply. Within Zone and Division Megablocks are designed for installation in intrinsically safe applications, and are compatible with or Entity-approved field instruments. An energy-limited or intrinsically safe fieldbus allows live connection/disconnection of the fieldbus without the need for a gas clearance certificate, which assists in commissioning, maintenance and system expansions. Alternatively, for applications using flameproof certified devices, the Megablocks are designed to meet the requirements for increased safety for installation in an Ex e junction box in Zone. To select the Megablock for your application see the Ordering Information section of this document. EPS MEG Rev enquiry@mtl-inst.com
2 INSTALLATION Megablocks can be mounted vertically or horizontally using 5 mm DIN rail within a suitable enclosure, such as a field junction box. Megablocks are removed from the DIN rail using a flat blade screwdriver to release the mounting platform. Use of DIN rail end stops is recommended to prevent sliding in vertical installations. Four, eight and ten port Megablocks have labeling areas so that segments can be easily identified according to plant standards. MTL have a wide range of standard junction box designs for use with Megablocks. See the data sheet for the range of Process JBs. Shown above is an example of a common Fieldbus segment topology. Eight field devices are connected to an eight-drop Megablock, which is mounted in a field junction box. One trunk connector on the Megablock is wired to a Megablock Terminator and the other to the segment trunk cable that leads to the control room or marshalling panel where the power supply and second terminator are located. The Megablock Terminator in the field has a normally open connection to earth ground that closes when surge conditions are detected. GROUNDING To prevent ground loops, a fieldbus segment should only be grounded at one point. This is usually done by grounding the cable shield at the control room end of the segment. If a permanent segment ground connection in the field is desired, this can be achieved by wiring the shield terminal on one of the Megablock trunk connectors to a suitable earth ground instead of wiring it to the shield terminal on the Megablock Terminator. Fieldbus Connection System (FCS) wiring blocks are protected by U.S. Patents 6,66,, 6,69,99 and 6,59,5. SPECIFICATIONS Mounting Requirements: 5mm DIN rail Wire Capacity: 0. to.5mm Case material: Lexan Polycarbonate Temperature Range: 5º to +0ºC Voltage Required to activate LED: 9.V dc minimum FCS-MBX MEGABLOCK Consumption:.mA maximum Maximum Current Delivered to Spur: Not Limited Trunk to Spur Voltage Drop: 0V FCS-MBX-SG, F & F5 MEGABLOCK WITH SPURGUARD Consumption: No SpurGuards tripped:.5ma per SpurGuard tripped: 60mA Maximum Current Delivered to Spur: 5.mA ±.ma Trunk to Spur Voltage Drop (SpurGuard not tripped): DC Impedance: Ω Typical: 0.V dc (ma device current draw) Trunk to Trunk Voltage Drop: 0V F - F INTRINSICALLY SAFE MEGABLOCK WITH SPURGUARD Consumption: with no SpurGuards tripped: ma (F,F5), ma (F5,F59).5mA (F) per SpurGuard tripped: ma Maximum Current Delivered to Spur: 0.9mA ±.0mA Trunk to Spur Voltage Drop (SpurGuard not tripped): Typical: 0.V dc (ma device current draw) DC Impedance: 5Ω Trunk to Trunk Voltage Drop: 0V F5-XE - F-XE INCREASED SAFETY (EX EM) MEGABLOCK WITH SPURGUARD Consumption: with no SpurGuards tripped:.9ma per SpurGuard tripped: ma Maximum Current Delivered to Spur: 0.9mA ±.0mA Trunk to Spur Voltage Drop SpurGuard not tripped: 0.V maximum Trunk to Trunk Voltage Drop: 0V FCS-MBT & F00 MEGABLOCK TERMINATOR Operating Temperature Range: 5º to +0ºC Common Mode Voltage Limit: 9V Transient Mode Voltage Limit: 5V PHYSICAL NETWORK IEC 65- Foundation fieldbus H Profibus PA EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
3 ORDERING INFORMATION No SpurGuard With SpurGuard short circuit protection General Purpose Zone/Division and Intrinsically Safe General Purpose and Zone/Division Zone/Division Intrinsically Safe Zone Ex em Megablocks way FCS-MB FCS-MB-SG F - way FCS-MB FCS-MB-SG F5 F5-XE way with internal Terminator - FCS-MB-SG-T F F-XE way FCS-MB FCS-MB-SG F5 F5-XE way with internal Terminator - FCS-MB-SG-T F5 F5-XE 0 way - FCS-MB0-SG way with internal Terminator FCS-MB0-T FCS-MB0-SG-T F59 F59-XE 0 way with switched Terminator - F F6 - way - FCS-MB-SG - - way with internal terminator - FCS-MB-SG-T F F-XE way with switched Terminator - F5 - - Terminators F00* FBT-IS F00 FBT-IS FCS-MBT FBT-IS FCS-MBT-XE * Use FCS-MBT for intrinsically safe applications See Terminators datasheet for full details ACCESSORIES Description Heavy Duty DIN rail end stop 5mm DIN Rail, metre lengthw Process JB stainless steel, painted Process JB carbon loaded GRP Process JB stainless steel Part Number ETL000 THR000 FCS-5XX FCS-5XX FCS-95XX See Process JB data sheets for further details EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
4 CASE DIMENSIONS -WAY MEGABLOCK." 56. mm -WAY MEGABLOCK.66" 6.6 mm FCS-MB-SG FCS-MB-SG (50)5-560Made in USA.6" 5.9 mm (50) Made in USA.6" 0. mm.9".9" -WAY MEGABLOCK 0-WAY MEGABLOCK.66" 6.6 mm." 56. mm FCS-MB-SG FCS-MB0-SG-T 5 (50) Made in USA 6 5.6". mm.9" T (50) Made in USA " 56.5 mm Note: Different Megablock versions have minor variations in labelling..9" EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
5 CASE DIMENSIONS (cont) -WAY MEGABLOCKS FCS-MB-SG-T F5, F, F-XE." 56. mm." 56. mm FCS-MB-SG-T F Trunk 5 6 Relcom T 9 0.6".9 mm 5 6 Relcom T 9 0.6".9 mm.9".9" EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
6 APPROVALS - for full certification information visit MODELS - F00, FCS-MBT, FCS-MB, FCS-MB, FCS-MB, FCS-MB0-T Country Europe USA Canada Canada Europe Authority ATEX (Category ) FM CSA CSA LCIE Standard EN : 006 EN : 005 E II G Ex na[l] IIC T 6 C. No. - M9 CAN/CSA - E T Ex na IIC T C. No. 5-9 CAN/CSA - E9--95 Ex ia IIC T EN : 006* EN6009- : 00* E II G Ex ia IIC T Certificate no. RELC0ATEX00X LCIE0ATEX6X Cable (Spur) Energy limited Ui=V Ii=.5A Non-arcing Non-arcing Vmax, Ui=V Imax, Ii=50mA Pi=.W Vmax, Ui=.5V Imax, Ii=0mA Pi=5.W Vmax, Ui=V Imax, Ii=50mA Pi=.W Note Non-arcing Non-arcing As trunk As trunk Uo = V Io = 50mA Co = 6nF Lo = 56μH Po =.W Note Vmax, Ui=.5V Imax, Ii=0mA Pi=5.W Uo =.5V Io = 0mA Co = 6nF Lo = 6μH Po = 5.W Note * the original LCIE Certificate used EN 500:99 + Amendments & and EN 5000:99. We have determined that there are no technical differences (affecting the products) between these standards and the currently harmonized EN standards listed above. Note : Spur is Energy-limited only if trunk is installed as Energy-limited, in which case spur field wiring are as source of supply to trunk, and limited to V and.5a max. Note : The figures quoted apply to IIC gas group. See certificate for parameter relating to groups IIB and IIA MODELS - F, F5, FCS-MB-SG-[T], FCS-MB-SG-[T], FCS-MB-SG-[T], FCS-MB0-SG-[T], FCS-MB-SG-[T] Country Europe USA USA Canada Canada Authority ATEX (Category ) FM FM CSA CSA Standard EN : 006 EN : 005 E II G Ex na[l] IIC T 6 6 C. No. - M9 CAN/CSA - E IEC T T Ex na [nl] IIC T C. No. - M9 CAN/CSA - E Ex na IIC T Certificate no. RELC0ATEX00X Cable (Spur) Energy limited Ui=V Ii=.5A Energy limited Uo=V Io=60mA Co=0nF Lo=.6mH Note Non-arcing Non-arcing Non-arcing Non-arcing Non-arcing Non-incendive Voc=V Isc=60mA Ca=0nF La=.6mH Non-incendive Voc=V Isc=60mA Ca=0nF La=.6mH Note : Trunk may be installed as Energy-limited or Non-sparking circuit; Spur is Energy-limited in either case. Non-arcing EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
7 APPROVALS - for full certification information visit MODELS - F, F5, F, F5, F5, F59, F6, F Country Europe USA USA & Canada International Authority KEMA FM CSA IECEx Standard EN : 006* EN : 00* E II G Ex ia IIC T IS/I//ABCD/T Ta=0ºC I/0/AEx ia IIC T Ta=0ºC 60 C. No. 0 - M9CAN/ C. No. 5-9 CAN/CSA - E CAN/CSA - E9--95 FM600, FM60 Ex ia IIC T IEC : 000 IEC6009- : 999 Ex ia IIC T Certificate no. KEMA0ATEX555X 005 IECExCSA06.000X Ui V Ii 50mA Pi.W Ui.5V Ii 0mA Pi 5.W Vmax = V Imax = 50mA Pi =.W Vmax =.5V lmax = 0mA Pi = 5.W Vmax, Ui = V Imax, Ii = 50mA Pi =.W Vmax, Ui =.5V lmax, Ii = 0mA Pi = 5.W Ui = V Imax, Ii = 50mA Pi =.W Ui =.5V lmax, Ii = 0mA Pi = 5.W * the original KEMA Certificate used EN 500:99 and EN 5000:00. We have determined that there are no technical differences (affecting the products) between these standards and the currently harmonized EN standards listed above. Model F currently has only KEMA approval to the standards indicated. MODELS - F5-XE, F-XE, F5-XE, F5-XE, F59-XE, F-XE, FCS-MBT-XE Country Europe Authority KEMA Standard EN : 00 EN : 00 EN : 00 Certificate no. Trunk wiring E II G Ex em IIC T KEMA05ATEX006 Rated voltage 0V DC Rated current.5a MODEL - FBT-IS Country Europe US Authority BASEEFA FM Standard EN500(99) +A & A EN5000 (00) II G EEx ia IIC T (-0ºC Ta +0ºC) 60 Entity IS/I//ABCD/T Ta=0ºC I/0/AEx ia IIC T Ta=0ºC Certificate no. Baseefa 0ATEX00 06 Ui = 0V Ii = 50mA Pi =.W Ui =.5V Ii = 0mA Pi = 5.W Vmax = 0V Imax = 50mA Pi =.W Vmax =.5V lmax = 0mA Pi = 5.W EUROPE (EMEA): + (0)5 6 THE AMERICAS: ASIA-PACIFIC: +65 6
megablock series passive hubs for fieldbus networks
passive hubs for fieldbus networks Relcom megablock series Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They connect several field devices to the network trunk cable and
More informationF2xx & F2xx-XE Megablock Series
technical datasheet technical datasheet Fxx & Fxx-XE Megablock Series passive hubs for Zone & Division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation fieldbus networks. They
More informationF2xx & F2xx-XE megablock range
Technical data MTL fieldbus networks September 0 EPS Fxx rev Fxx & Fxx-XE megablock range Passive hubs for zone & division fieldbus networks Megablocks are DIN-rail mounted passive hubs for Foundation
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 0202 USA T: 781 72 400 F: 781-72-975 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL EQUIPMENT
More informationIP26 Series Current to Pneumatic Converter
Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 3/06 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature
More informationSTT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C
STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C 6/07 PRODUCT SPECIFICATION SHEET OVERVIEW The Honeywell STT170 series of programmable temperature transmitters
More informationDPharp Differential Pressure and Pressure Transmitters
User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change
More informationAnalog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/
> 4 channels for 2-wire HART transmitters and 4 channels for 4-wire HART transmitters > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationWhite Paper. Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment. March 24, 2005
White Paper Requirements for fieldbus equipment installed in a Zone 2 and Division 2 hazardous area environment March 24, 2005 up Königsberger Allee 87 68307 Mannheim Germany Tel. + 49 621 776-0 Fax +49
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationDigital Input Module 24 V Ex n Inputs, 16 Channels Series 9471
> 16 channels for active 0 / 24 V signals > Zone 2 / Division 2 version for connection of circuits acc. to Ex nl, Ex na, Nonincendive and Non-Ex > Galvanic separation between inputs and system > Two channels
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More informationFieldbus Solutions & Network Topologies. ISA Exhibition Toronto May 12, 2004
Fieldbus Solutions & Network Topologies ISA Exhibition Toronto May 12, 2004 Fieldbus Solutions During this presentation we will talk about different network topologies and Fieldbus solutions for different
More informationPower supply. Calibration. Surface finishing. Seal. Process connection
Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst
More informationAnalog Universal Module HART for Zone 2 Series 9468/33
> 8 channels can be adjusted individually as analog inputs or outputs > Intrinsically safe inputs/outputs Ex ia > For 0/4 20 ma + HART signals > Line fault monitoring per channel > Diagnostics based on
More informationIECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRev ECN Description Approval Date AA Release to Approvals RCS 10/9/12
EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page
More information2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER
SAFE INSTALLATION MANUAL (FM APPROVAL) -WIRE UNIVERSAL TEMPERATURE TRANSMITTER (HART communication, intrinsically safe/explosion-proof) MODEL B6U/B6U-B BEFORE USE... SAFETY PRECAUTIONS This manual describes
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General
More informationBinary Output without Power Supply Series 9176
Binary Output without Power Supply Series 9176 > For intrinsically safe operation of Ex i solenoid valves, indicators and horns > Power supply by control circuit, loop powered > Intrinsically safe output
More informationTemperature Input Module for Zone 1 Series 9482/32
www.stahl.de > 8 channels for temperature sensors > Intrinsically safe inputs Ex ia > For Pt-, Ni- and Cu-resistance temperature detectors according to DIN, IEC and GOST in 2-, 3- and 4-wire circuits >
More informationATEX Installation Drawings and Instructions
Installation Instructions P/N 20004414, Rev. C September 2008 ATEX Installation Drawings and Instructions For ATEX-approved transmitter installations Note: For hazardous installations in Europe, refer
More informationHead mounted Temperature Transmitter TF02/TF02-Ex
Data Sheet Head mounted Temperature Transmitter TF0/TF0-Ex FOUNDATION Fieldbus H, Pt 00 (RTD), thermocouples, or independent channels Input Resistance thermometer (-, -, -wire circuit) Thermocouples Resistance
More informationControlNet Ex Tap Terminator Installation Instructions
Installation Instructions Tap Terminator Installation Instructions (Cat No 1797-TCAP) Use this document as a guide when you install a ControlNet TM Ex tap terminator This document will be packaged with
More informationDigital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22
www.stahl.de > 16 channels for contacts and NAMUR proximity switches (EN 60947-5-6) > Intrinsically safe inputs Ex ia IIC > Galvanic separation between inputs and system > Open-circuit and short-circuit
More informationD1061S INSTRUCTION MANUAL. RS422/RS485 Fieldbus Isolating Repeater Din-Rail Model D1061S. D RS422 / RS485 Fieldbus Isolating Repeater
DS INSTRUCTI MANUAL RS/RS Fieldbus Isolating Repeater Din-Rail Model DS D - RS / RS Fieldbus Isolating Repeater ISM00- Characteristics General Description: The single channel DIN Rail RS / RS Fieldbus
More informationGeneral Specifications
General Specifications Model YTA110 Temperature Transmitter GS 01C0B01-00E [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs
More informationCOMMUNICATION NETWORKS
Zone Applications (PROFIBU PA) MB eptember 2008 COMMUNICATION NETWORK FOR ZONE APPLICATION (PROFIBU PA) Michael Bean - 8 eptember 2008 INTRODUCTION: In recent years it has become increasingly popular to
More informationGeneral Specifications
General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to
More informationTF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels
TF 0 / TF 0-Ex Head mounted temperature transmitters, FOUNDATION Fieldbus (H), Pt 00 (RTD), thermocouples, or independent channels 0/-8.5 EN Input Resistance thermometer (,, wire circuit) Thermocouples
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Provides an installation-ready solution for temperature monitoring applications using Complete Point Solutions (CPS) Increases measurement
More informationSTT 3000 Smart Temperature Transmitter Series STT170 Specifications
STT 3000 Smart Temperature Transmitter Series STT170 Specifications Model STT171, STT173, STT17H, STT17F, STT17C 34-TT-03-07 November 2010 Overview STT17H Features The Honeywell STT170 series of programmable
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers
Instruction Manual Supplement DVC6005 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers Hazardous Area Approvals and Special Instructions
More informationFM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationSpecifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift
Appendix A Specifications 1797-IE8 and -IE8NF Input Modules Specifications Number of Inputs IS Input Type IS Module Type Resolution Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift Functional
More informationR88000 T (including ATEX)
INSTRUCTION MANUAL R88000 T88000 (including ATEX) Factory set transmitters are ready to use. Connect according the labels. Otherwise follow the calibration instructions. Input signals ṮC RTD CONTENTS:
More informationModel 264IB. ABB 2600T Series Engineered solutions for all applications
Data Sheet DS/264IB-EN Rev. B ABB 2600T Series Engineered solutions for all applications FOUNDATION Fieldbus field indicator up to 8 H1 variables one selectable host variable FOUNDATION Fieldbus blocks
More informationCSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers
Instruction Manual Supplement DVC6200 Digital Valve Controllers CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers SIS Hazardous Area Approvals and Special Instructions
More informationRemote I/O. 74 Remote I/O. Remote I/O System
System Overview of the System Components IS1+ 76 General Information IS1+ 77 CPU & Power Modules CPU & Power Modules for Zone 1 / Div. 1 IS1+ 9440/22 78 Sockets for CPU & Power Module IS1+ 9490 78 CPU
More informationDigital I/O Coupler (4-wire) Series 9413/21
Digital /O Coupler (4wire) > The digital /O coupler is used to connect 8 intrinsically safe contacts or proximity initiators and 4 intrinsically safe solenoid valves to a FOUNDATON TM fieldbus H1. > Galvanic
More informationIsolators A3/1. Vibration Transducer Supply Unit Series
> For vibration, acceleration and speed sensors in 2- and 3-wire design > Space-saving dual-channel version > Signal frequencies up to 50 khz > Easy setting by means of front-side rotary switch > Galvanic
More informationTitle: INTRINSIC SAFETY MADE EASY
Title: INTRINSIC SAFETY MADE EASY By: TH Kuan KL Automation Engineering Sdn. Bhd. ICA 2006 Date: 19.02.2006 Profile of Kuan Teik Hua Mr. Kuan is a Director for KL Automation Engineering Sdn Bhd. He has
More informationGeneral Specifications
General Specifications EJX Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by Fieldbus
More informationGeneral Specifications
General Specifications FN310 Field Wireless Multi-Protocol Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Protocol Module. Combined with Field Wireless
More informationDATASHEET F090 - GENERAL PURPOSE INDICATOR
GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual
More informationIsolators A3/1.
> Compact limit value switch with 2 configurable limiting values and 4... 20 ma output > Suitable for 2-, 3-wire transmitters, 2-wire HART transmitters and ma sources > Intrinsically safe input [Ex ia]
More informationPressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751
060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions
More informationSINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator
SINEAX TI 807 without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically
More informationSINEAX TI 807 Passive DC signal isolator
without power supply, Ex- and non-ex version, in housing N17 or S17 for rail and wall mounting 0102 II (1) G resp. II (2) G Application The signal isolator SINEAX TI 807 serves to electrically insulate
More informationField indicator for current loops with HART communication Models DIH50, DIH52
Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 7 Applications Process engineering Plant construction General
More informationIsolators A3/1. Ex i Power Supply Field Circuit Ex i Series
> Intrinsically safe output [Ex ib] IIC/IIB > Stable output voltage > Galvanic isolation between output and power supply > Power supply or 85... 230 V AC > Compact design www.stahl.de 07673E00 Basic function:
More informationDigital Input Output Module for Zone 2 Series 9470/33
www.stahl.de > 16 channels can be adjusted in pairs as digital input or output > Intrinsically safe inputs/outputs Ex ia > For contacts, NAMUR proximity switches and low-power solenoid valves > Up to 8
More informationGENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR
GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR Features Universal loop powered indicator. Very large 26mm (1 ) high digits. Displays the actual
More informationGeneral Specifications
General Specifications YTA60 Temperature Transmitter The YTA60 is the highly accurate temperature transmitter that accepts Thermocouple, RTD, ohms or DC millivolts inputs and converts it to a to 0 ma DC
More informationRosemount 848L Logic Transmitter with FOUNDATION Fieldbus
Logic Transmitter with FOUNDATION Fieldbus Integrates Discrete I/O on a FOUNDATION Fieldbus H1 Segment Reduces Installation and Maintenance Costs with a Single Network for Analog and Discrete devices Easily
More informationSolexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:
OVERVIEW The Solexy RX series explosion proof and intrinsically safe antenna coupler is an integrated protection device that facilitates non-ex certified radio antenna installation in hazardous areas.
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Basic temperature transmitter offers a cost-effective solution for temperature monitoring points transmitter design provides flexible
More informationOperating Manual. isolate501
Operating Manual isolate501 Document Number 413569 (See Last Page for Revision Details). Copyright Extronics Ltd, 2015 Page 2 of 21 Contents 1 Introduction... 4 2 Safety Information and Notes... 5 2.1
More informationYTA610 and YTA710 Temperature Transmitter (Hardware)
User s Manual YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition 1 YTA610 and YTA710 Temperature Transmitter (Hardware) 2nd Edition CONTENTS 1. Preface... 1-1 Notes on the User s Manual...1-1
More informationLoop Powered Indicator
Instruction Manual Model PD686 Loop Powered Indicator M397 January 3, 2019 JOWA USA, Inc. 59 Porter Road Littleton, MA 01460-1431 USA Tel: 978-486-9800 Fax: 978-486-0170 PD686 I.S. and N.I. NEMA 4X, IP67
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F
Series 9160 Rev. F > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de
More informationVTM Local Display Unit with Frequency and Analogue Output
Küppers Elektromechanik GmbH Flow Meters Liebigstr. 2 D-85757 Karlsfeld Phone +49 81 31/59 39 10 Fax + 49 81 31/9 26 04 VTM Local Display Unit with Frequency and Analogue Output The VTM is a programmable
More informationInstallation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model 3500 Transmitters
Installation Instructions P/N MMI-20011707, Rev. AA July 2009 ATEX Installation Instructions for Micro Motion Model 3500 Transmitters Note: For hazardous installations in Europe, refer to standard EN 60079-14
More informationFLEX Ex System Certification
FLEX Ex System Certification 1797 Series Reference Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines
More informationIsolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series
Transmitter Supply Unit Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring and messaging for input
More informationtechnical datasheet technical datasheet MTL7700 Series DIN-rail mounting safety barriers
technical datasheet technical datasheet MTL7700 Series DIN-rail mounting safety barriers Removable terminals feed to other modules Relay and solid state switch modules Dual channel variants.mm per channel
More informationProduct manual wire programmable RTD transmitter
Product manual 5332 2-wire programmable RTD transmitter PERFORMANCE MADE SMARTER TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY No. 5332V100-UK From serial no: 181903001
More informationD1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater
D1035S INSTRUCTION MANUAL FrequencyPulse Isolating Repeater DIN Rail Model D1035S D1035 FrequencyPulse Isolating Repeater ISM007910 Characteristics General Description: The single channel DIN Rail FrequencyPulse
More informationSingle-Channel Safety Barriers with Electronic Current Limitation Series 9004
Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More informationINSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q
DQ DQ DQ D3Q INSTRUCTION MANUAL SIL 3 SIL Digital Output Loop/Bus Powered DINRail Models DQ, DQ, DQ, D3Q, D* SIL 3 SIL Digital Output Loop / Bus Powered ISM SIL Applications For Safety Related System and
More information09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i
Temperature Transmitter Series 9182 www.stahl.de > One unit for nearly all temperature sensors indivdually configurable > Intrinsically safe input [Ex ia] IIC > Signal duplication possible > Galvanic isolation
More informationBinary Output Series 9175
Binary Output > Intrinsically safe output [Ex ia] IIC / [Ex ib] IIC > Galvanic isolation between input, output and power supply > Open-circuit and short-circuit monitoring (can be switched off) > For use
More informationModel 144H NEW. PC-Programmable Temperature Transmitter. Product Data Sheet
Product Data Sheet 00813-0101-4796 Model 144H PC-Programmable Temperature Transmitter FEATURES Configurable using the Model 144C Configuration Interface hardware and software Programmable via standard
More information2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004
2 Safety Barriers Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Broad product range for all standard applications in the world of automation Flexible and space saving Time
More informationSEM210 SERIES. Programmable In-head Universal Temperature Transmitter INDEX SECTION CONTENTS PAGE NO.
INDEX SECTION CONTENTS PAGE NO. SEM210 SERIES 1.0 DESCRIPTION 1 2.0 SPECIFICATION 15 3.0 INSTALLATION 67 Programmable Inhead Universal Temperature Transmitter Status Instruments Ltd, Green Lane Business
More informationDigital Input Output Module 24 V for Ex n Zone 2 Series 9472/35
www.stahl.de > 16 channels can be adjusted in pairs as digital inputs or outputs > Suitable for NAMUR proximity switches, 3-wire PNP proximity switches, contacts and solenoid valves (24 V / 0.5 A). > Up
More informationInstallation guide 971 SmartRadar LTi
Installation guide 971 SmartRadar LTi March 2009 Part no. 4416.715 Revision 3 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywellenraf.nl
More informationOperator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique
Operator Manual Transmitters Series KAT-... Analog transmitters in 2-wire technique Important Safety Notes! In the case of non-observance of the installation and safety notes or improper use of the transmitter
More information... for hydraulic and general applications in hazardous areas
ATEX Approved Inductive... for hydraulic and general applications in hazardous areas Inductive Namur sensors Explosion protected Ignition class "intrinsically safe" when used together a suitable certified
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and
More informationprotim-r Module
200200 protim-r Module Description The 200200 dual-input protim-r (DIN Rail mount) provides two channels of measurement. All acceleration-to-velocity (A-V) channels condition the signal from an accelerometer
More informationBAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description
BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.
More informationGeneral Specifications
General Specifications FN510 Field Wireless Multi-Function Module GENERAL This General Specification (GS) describes the specifications for Field Wireless Multi-Function Module. Combined with Field Wireless
More informationAnalogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting
Electrical Temperature Measurement Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting WIKA Data Sheet TE 24.01 Applications T Machinery, plant construction T Process industry
More informationInstallation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN
Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement
More informationRosemount 148 Temperature Transmitter
Product Data Sheet Rosemount 148 Rosemount 148 Temperature Transmitter Ready-to-install solution for temperature monitoring applications Increased measurement accuracy and reliability Accepts 2-, 3-, and
More informationFisher 646 Electro Pneumatic Transducer
Product Bulletin D101374X012 646 Transducer Fisher 646 Electro Pneumatic Transducer The Fisher 646 electro pneumatic transducer, shown in figure 1, uses a converter module that converts a 4 to 20 milliampere
More informationInstallation & Operating Manual. iwap202
Installation & Operating Manual iwap202 This page is intentionally left blank. Document Number 409345 (based on 407655) (See Last Page for Revision Details) For warranty information, refer to Terms and
More informationCERTIFICATE OF COMPLIANCE
FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 USA T: 781 762 4300 F: 781-762-9375 www.fmapprovals.com CERTIFICATE OF COMPLIANCE HAZARDOUS (CLASSIFIED) LOCATION ELECTRICAL
More information1 About this manual Related documents Product description Getting started Mechanical installation...
CONTENTS PAGE 1 About this manual... 1 1.1 Related documents... 1 1.2 Product description... 1 2 Getting started... 1 3 Mechanical installation... 1 3.1 Location... 1 3.2 Mounting options... 1 CONNECTIONS...
More informationDigital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version
Temperature Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version WIKA data sheet TE 15.01 for further approvals see page 10 Applications
More information06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500
Switching Repeater Series 9170 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > Open-circuit / short-circuit monitoring and messaging (can be switched
More informationThe T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.
GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional
More informationIndustrial Pressure Transducers
Industrial Pressure Transducers User s Manual T Model T Model The Swagelok T model transducer is engineered for use in industrial pressure measurement applications where intrinsically safe ratings are
More informationIECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationElectrodynamic Velocity Sensor
PR9268 Specifications Sheet July 2018 Electrodynamic Velocity Sensor Mechanical velocity sensor for absolute vibration measurement of critical turbomachinery applications such as steam, gas and hydro turbines,
More informationPRetrans Table of contents
HART TRANSPARENT REPEATER PRetrans 5106 Table of contents Warnings 16 Safety instructions 17 EC Declaration of Conformity 19 How to demount SYSTEM 5000 20 Application 21 Technical characteristics 21 Mounting
More informationTransducer transmitter BILT 4 II 2(1) G. Technical Manual
GB Transducer transmitter BILT 4 II 2(1) G Technical Manual Transducer transmitter BILT 4 Contents Introduction General... 3 Ex.safety description... 4 Technical data... 5 Installation General... 6 Mechanical
More information