1 FETURES The monostable spool valves have TÜV certified IE 60 Functional Safety data and can be used up to SIL 4 ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) an be externally piloted (external air pilot supply) to convert valve to zero minimum operation by flipping a gasket The solenoid valves satisfy all relevant E Directives GENERL Differential pressure Flow (Qv at 6 bar) SOLENOID VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) brass body, /4 2-0 bar [ bar =00 kpa] 60 l/min (NR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - 40 to + 60 VMQ (silicone) + PUR (polyurethane) /2 Series MTERILS IN ONTT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified ody, end covers rass Spool valve internal parts rass, stainless steel, POM ore tube Stainless steel ore and plugnut Stainless steel ore spring Stainless steel Seals & discs NR Top disc P Disc holder POM artridge (low power) Welded, packless ISI 40 Seat rass Seat insert POM Shading coil opper Rider ring (low power) PTFE P RP-MP LP UP Not vailable 0,4W - 2W Not vailable 0,W -,2W Ultra Low power Low power Reduced and Medium power asic power POWER LEVELS - cold electrical holding values (watt) SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) optional solenoids power max. (PS) level NEM TEX / IEEx min. (2) basic catalogue number IP6 air ( ) 7 & Ex d Ex emb Ex mb Ex ia EEx n ( ) (mm) (m /h) (l/min) ~ = ~/= EF LPKF NF EM PV LI IS ZN S Solenoid air pilot operated - spring return (monostable) /4 6 0,7 2, 0 / P () /4 6 0,7 2, 0 / P G4 () /4 6 0,7 2, 0 / LP - m - m m m m () /4 6 0,7 2, 0 / LP m G () Solenoid air pilot operated and return (bistable) /4 6 0,7 2, 0 / P /4 6 0,7 2, 0 / P G420 /4 6 0,7 2, 0 / LP - m - m m m m 20 /4 6 0,7 2, 0 / LP m G20 Select for NPT NSI.20. or select G for ISO G (22/) vailable feature vailable feature in D only. () ertified IE 60 Functional Safety data, use suffix "SL" (Not to use with LPKF suffix). (2) Zero minimum is only achieved if external pressure is applied. ll leaflets are available on: PI---G 20/R0

2 SERIES PREFIX TLE power level description LP RP MP P S D U Dustproof (EN 02--)* E F Explosionproof - NEM 7, - Zinc plated steel conduit m - - E V Explosionproof - NEM 7, - 6 SS conduit m - - E M Waterproof IP67 - Metal enclosure (EN/IE , 624-)* - - E T Threaded conduit/hole (M20 x,) - - I S S Intrinsically safe with S coil (EN/IE , 624-)* m L P K F Flameproof - luminium (EN/IE 6007-, 624-)* N F Flameproof - luminium (EN/IE 6007-, 624-)* - - P V Encapsulated epoxy moulded (EN/IE 6007-, 624-)* m - - S Solenoid with spade plug connector (EN/IE 6070) - - W P Waterproof IP67 - Metal enclosure - - W P D U Waterproof IP67 - Metal enclosure, Dustproof (EN 02--)* L I I.S. with luminium IP67 enclosure (EN/IE / 624-)* m W P I S I.S. with Metal IP67 enclosure (EN/IE , 624-)* m W S Waterproof IP67-6 SS enclosure - - W S D U Waterproof IP67-6 SS enclosure, Dustproof (EN 02--)* W S L P K F Flameproof - 6 SS (EN/IE 6007-, 624-)* W S E M Waterproof IP67-6 SS enclosure (EN/IE , 624-)* - - W S L I I.S. with 6L SS IP67 enclosure (EN/IE 6007-, 624-)* m W S I S I.S. with 6 SS IP67 enclosure (EN/IE , 624-)* m W S N F Flameproof - 6 SS (EN/IE 6007-, 624-)* - - Z N Moulded enclosure (EN 002, 02--)* m - - T Threaded conduit (/2" NPT) - - H T lass H - High temperature, +0 ambient temp X Other special constructions - - SUFFIX TLE suffix power level description LP RP MP P M O Push type manual operator / - - S L ertified IE 60 Functional Safety data (2) / - - PRODUT SELETION GUIDE STEP Select the fluid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications table above. Example : G4 STEP 2 Select (combination). Select the appropriate operator from the specifications table on page and the table on page 2. Select for this operator in the electrical characteristics table on page : the power level (LP, P), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : EM STEP Select suffix (combination) if required. Example : MO STEP 4 Select voltage. Refer to standard voltages on page. Example : 20V / 0Hz OPTIONS & ESSORIES series pipe exhaust protector (stainless steel) G / () NPT / () G / () NPT / () M () vailable feature m vailable feature in D only - Not available * TEX solenoids are also approved according to EN 46- (non electrical valves) () Provided with "SL" suffix (2) Not to use with MO suffix ORDERING EXMPLES: () pipe thread basic number () STEP Final catalogue / ordering number. Example : EM G4MO 20 V / 0 Hz S G 0V / 0 Hz S G 4 SL 20V / 0 Hz S G 420 MO 20V / 0 Hz SHT 420 MO 20V / 0 Hz ISS G 420 MO 24V / D WSLPKF G MO 24V / D LPKF G MO 24V / D LI G 24V / D WSLI G 20 MO 24V / D WPIS G 24V / D EM 4 MO 20V / 0 Hz EF G G 4 MO 240V / 60 Hz voltage suffix () Prefixes EF and EV should always be used with the letter G in the basic number. ll leaflets are available on: /R0

3 EXPLNTION OF TEMPERTURE RNGES OF SOLENOID VLVES SERIES Valve temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) Operator ambient temperature range The operator ambient temperature range is determined by the selected power level and the safety code Total temperature range The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELETRIL HRTERISTIS oil insulation class F Electrical safety IE Standard voltages D (=) 24V - 4V (~) 24V - 4V - V - 20V () /0Hz; other voltages and 60Hz are available on request power ratings operator electrical ambient replacement coil / kit inrush holding hot/cold temperature enclosure safety code type option range (TS) protection (2) ~ ~ = ~ = (V) (V) (W) (W) ( ) () (EN 602) 20 V/0 Hz 24V/D asic power (P) S 2 0, /,2-40 to +7 EN 6070 IP6 moulded SDU 2 0, /,2-40 to +7 IID IP6 T 200 (~)/ (=) IP6 moulded - (4) - (4) 0 WP/WS 2 0, /,2-40 to +7 EN 6070 IP67 steel/ss WPDU/WSDU 2 0, /,2-40 to +7 IID IP67 T 200 IP67 steel/ss - (4) - (4) 04 NF/WSNF 2 0, - (-60) (7) -40 to +2/40/60 II2G Ex d II T6/T/T4, II2D Ex td IP67 alum./ss NF/WSNF /,2 (-60) (7) -40 to +40/60/7 II2G Ex d II T6/T/T4, II2D Ex td IP67 alum./ss EM/WSEM 2 0, /,2-40 to +40 II2G Ex e mb II T, II2D Ex td IP67 steel/ss PV 2 0, /,2-40 to +6 II2G Ex mb II T(~)/T4(=),II2D Ex md 2 IP67 moulded - (4) - (4) 0 EF/EV 2 0, /,2-40 to +4/40 NEM type 7 and NEM 4X ZN 2 0, /,2-20 to +0 IIGD EEx n II T IP6 moulded - (4) - (4) 0 Low power (LP) S,,,,7/,7-40 to +60 EN 6070 IP6 moulded WP/WS,,,,7/,7-40 to +60 EN 6070 IP67 steel/ss LPKF/WSLPKF () 2,,,4 0,/0, () -40 to +0/60 II2G Ex d II+H2 Gb T4/T6, II2D Ex t Db IP67 alum./ss - (4) - (4) NF/WSNF - -, - /, (-60) (7) -40 to +7/0 II2G Ex d II T6/T, II2D Ex td IP67 alum./ss - (4) () - (4) 0 EM/WSEM,,,,7/,7-40 to +40/ II2G Ex e mb II T6/T, II2D Ex td IP67 steel/ss - (4) - (4) 0 PV - - -,7/,7-40 to +6 II2G Ex mb II T6 / II2D Ex md 2 IP67 moulded - - (4) 0 EF/EV - - -,7/,7-40 to +60 NEM type 7 and NEM 4X - - (4) ISS () ,4/04-40 to +60 IIG Ex ia II T6, II2D Ex iad 2 IP6 moulded LI () ,/0, -40 to +60 II2G Ex ib II Gb T6, II2D Ex t III Db IP67 alum. - - (4) 4 WSLI () ,/0, -40 to +60 IIG Ex ia II Ga T6, II2D Ex t III Db IP67 SS - - (4) 4 WPIS/WSIS () ,4/04-40 to +60 IIG Ex ia II T6, II2D Ex iad 2 IP67 steel ZN - - -,7/,7-20 to +0 IIGD EEx n II T IP6 moulded - - (4) 07 option safety parameters U I = (D) I I P I L I I (V) (m) (W) (H) (µf) Low power (LP) ISS 2 00, 0 0 WPIS/WSIS 2 00, 0 0 LI/WSLI 2 00, 0 0 ELETRIL ONNETIONS S, SDU, ZN, ISS WP, WS, EM, WSEM, WPDU, WSDU, WPIS, WSIS NF, WSNF, LPKF, WSLPKF PV LI, WSLI EF, EV DDITIONL OPTIONS () Temperature range can be limited by sealings (2) Refer to the dimensional drawings on pages: 4 to 7 () ISS/WPIS/WSIS/LI/WSLI: heck the electrical characteristics in the corresponding catalogue pages (4) Multiple coil kits are available under TEX/IEEx, contact us () (WS)NF: Low Power, 20 V does not exist. Maximum voltage in is V (6) LI/WSLI: Low Power, 24 V D only (7) The certified minimum temperature of this operator () LPKF/WSLPKF: 24 V D, max. ambient temp. +0, contact us (4 V D = 2, W) - Not available connection Spade plug connector with cable gland EN70-0 (ISO 4400) for cables with an outer diameter from 6 to 0 mm M20 cable gland for cables with an outer diameter from 7 to 2 mm. With an internal and external facility for an earthing or bonding conductor /2" NPT threaded cable entry. Enclosures are supplied without cable gland Moulded-in cable, standard length 2 m /2 cable gland for cables with an outer diameter from 6 to 2 mm. With an internal and external facility for an earthing or bonding conductor /2" NPT conduits, standard length cm Valves configured for external pilot air supply, TPL 2047 Other pipe threads are available on request Ex mb/md ( "PV") solenoid can be supplied with various cable lengths ompliance with "UL", "S" and other local approvals available on request /2" NPT ( "T") and M20 x. ( "ET") conduits (aluminium or 6 SS) available for steel solenoid housing INSTLLTION Multi language installation/maintenance instructions are included with each valve The solenoid valves can be mounted in any position without affecting operation Do not connect the pressure supply to the exhaust port. The environmentally-protected construction is not adapted for a distributing function or use in NO function. ontact us for functions available in specific versions IE 60 Functional Safety (suffix SL), allowable temperature range: -40 to +60. For probability of failure, contact us It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: = NPT (NSI.20.); G = G (ISO 22/) Prefix "NF/WSNF" enclosure is provided with a /2" NPT threaded entry hole, M20 x, ( "ET") is optional. oth are supplied without cable gland ll leaflets are available on: /R0

4 SERIES DIMENSIONS (mm), WEIGHT (kg) ll types 4, / 6, x /4 27, = 22 = , 2 mounting holes. mm dia.; Spotfacing: mm dia., depth mm TYPE 0: Prefixes S: IP6, ZN: II G/D, IP6, EEx n II, SDU: II D, IP6, T00 to 200 asic power Epoxy moulded IE / ISO 4400 TYPE 02: Ex d II NF / WSNF luminium; epoxy coated / ISI 6 SS EN/IE and EN/IE / / G / /2 NPT 2 D E / 420 TYPE 04: WP / WS EM / WSEM WPDU / WSDU Steel; epoxy coated / ISI 6 SS IE / EN / and EN 624- / ll leaflets are available on: /R0

5 SERIES DIMENSIONS (mm), WEIGHT (kg) TYPE 0: PV Epoxy encapsulated EN/IE and EN/IE 624- TYPE 06: EF and EV: NEM type 7 and Epoxy encapsulated IS-6 NSI NOTE: applicable to solenoid only 4 / 420 G4 / G420 / / D 46 E D 2 E / 20 TYPE 07: S and ZN Epoxy moulded IE / ISO 4400 EN 002 / 20 TYPE 0: NF / WSNF luminium; epoxy coated / ISI 6 SS EN/IE and EN/IE / NPT /2 NPT 2 D E / 20 TYPE 0: WP / WS EM / WSEM WPIS / WSIS Steel; epoxy coated / ISI 6 SS IE / EN ///26 and EN 624-/ / 20 TYPE 0: PV Epoxy encapsulated EN/IE and EN/IE 624- / NPT 4 / NPT D 46 E ll leaflets are available on: /R0

6 SERIES DIMENSIONS (mm), WEIGHT (kg) H / G20 TYPE : Prefixes EF/EV: IS-6 NSI / NEM EF and EV: NEM type 7 and Epoxy encapsulated IS-6 NSI NOTE: applicable to solenoid only / / 20 TYPE 2: ISS Polypropylene moulded Epoxy moulded IE / EN 6007-/26 and EN/IE 624- / NPT D 2 E D 67 E TYPE : LPKF / WSLPKF luminium, cataphorese black painting / ISI 6L SS EN/IE and EN/IE 624- TYPE 4: LI: II 2G Ex ia II Gb T6, II 2D Ex t III IP67 Db WSLI: II G Ex ia II Ga T6, II 2D Ex t III IP67 Db luminium, cataphorese black painting, ISI 6L SS IE and EN: 6007-, 624- / 20 / 20 M 2 M /2NPT 0 /2 NPT ll leaflets are available on: /R0

7 SERIES DIMENSIONS (mm), WEIGHT (kg) type option power level D E weight () monostable bistable 0 S / SDU / ZN basic power ,7 22, 6,,2 2,2 02 NF basic power , - - 2,6 4,4 02 WSNF basic power , - -,,7 04 WP/WPDU/WS/WSDU/EM/WSEM basic power ,70 2,4 0 PV basic power , 67,, 2, 06 EF / EV basic power 44,, 22, 74,,40 2,2 07 S / ZN low power 44, 0, 22, 7,,67 2,7 0 NF low power , - - 2, 4, 0 WSNF low power , - -,, 0 WP / WS / EM / WSEM / WPIS / WSIS low power ,2 - -,7 2,72 0 PV low power , 22, 67,,7 2,6 EF / EV low power 44, 00, 22, 74,, 2,2 2 ISS low power , 22,,,0 2,4 LPKF low power ,66 2,6 WSLPKF low power ,27,76 4 LI low power ,67 2,7 4 WSLI low power ,2,77 () Incl. coil(s) and connector(s) 2 Ex d certified cable gland (on request) Three-core cable, length 2 m 4 able gland for unarmoured cable with 7 to 2 mm dia. sheath 6 onnector rotatable by 0 increments (cable ø 6-0 mm) Push type or screw type manual operator, suffix MO External pilot air supply, / pipe 0 able gland for unarmoured cable with 6 to 2 mm dia. sheath onnectable pilot exhaust port Non-connectable pilot exhaust port ESSORIES ø4 / NPT ø4 /4 NPT / NPT 20 pilot exhaust protector part number pilot top exhaust low power (SO solenoid interface) Ø Ø M / /4 4, 0 exhaust protector (stainless steel) ll leaflets are available on: /R0

8 SERIES ll leaflets are available on: /R0

9 SPOOL VLVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, / /2 Series FETURES The monostable spool valves have TÜV certified IE 60 Functional Safety data and can be used up to SIL 4 ll the exhaust ports of this spool valve are connectable, providing better environmental protection, particularly recommended for sensitive areas such as clean rooms, and applications in the pharmaceutical and food processing sectors The valve offers environmental protection against the ingress of liquids, dusts or any other foreign matter (environmentally-protected construction) The solenoid valves satisfy all relevant E Directives GENERL Differential pressure Flow (Qv at 6 bar) 2-0 bar [ bar =00 kpa] 60 l/min (NR) fluids ( ) temperature range (TS) seal materials ( ) air, inert gas, filtered - 40 to + 60 (2) VMQ (silicone) + PUR (polyurethane) (2) -40 for air operated versions. MTERILS IN ONTT WITH FLUID ( ) Ensure that the compatibility of the fluids in contact with the materials is verified ir operated NOMO solenoid (pilot) interface ody, end covers rass, ISI 6L rass, ISI 6L Spool valve internal parts rass, stainless steel, POM rass, stainless steel, POM Seals NR NR Pilot internal parts - Size (E N), refer to catalogue pages: 02 pilot (FS/FVT/FSIS) and 60 piezotronic pilot (PIS/PISIS) 2 4 IR OPERTED SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) optional basic catalogue number max. (PS) min. air ( ) ( ) (mm) (m /h) (l/min) ~ = Pilot air operated - spring return (monostable) /4 6 0,7 2, () Pilot air operated and return (bistable) /4 6 0,7 2, UP LP 0,00W-0,2W 0,W -,W Ultra Low power Low power RP-MP Not vailable Reduced and Medium power P Not vailable asic power POWER LEVELS - cold electrical holding values (watt) NOMO SOLENOID (PILOT) INTERFE SPEIFITIONS pipe orifice flow coefficient kv operating pressure differential (bar) power level optional solenoids basic catalogue number max. (PS) TEX / IEEx IP6 min. air ( ) Ex ia ( ) (mm) (m /h) (l/min) ~ = ~/= FSIS PISIS FS FVT PIS NOMO Solenoid air pilot operated - spring return (monostable) /4 6 0,7 2, LP () /4 6 0,7 2, 2 - LP m () /4 6 0,7 2, 2 UP - m - - () Solenoid air pilot operated and return (bistable) /4 6 0,7 2, LP /4 6 0,7 2, 2 - LP m /4 6 0,7 2, 2 UP - m Select for NPT NSI.20. or select G for ISO G (22/) vailable feature vailable feature in D only. () ertified IE 60 Functional Safety data, use suffix "SL". ll leaflets are available on: /R0

10 PREFIX TLE power level description UP LP RP P F S Solenoid + spade plug DIN 460,,4 mm, industry standard (EN 6070) F V T Solenoid with connection M2, LED + protection (EN 6070) - m - - F S I S Intrinsically safe,,4 mm, pilot 02; TEX (EN 6007 / 624) * - m - - P I S Solenoid, spade plug DIN 460,,4 mm, industry stand., TEX (EN 6070) P I S I S Intrinsically safe, piezotronic 60 pilot, TEX (EN 6007/624) * m SUFFIX TLE suffix power level description UP LP RP P G D Non-electrical, GD c, construction safety, gas/dust (EN 46-) M S Screw type manual operator () - / - - M O Push type manual operator / / - - S L ertified IE 60 Functional Safety data () / / - - OPTIONS & ESSORIES series exhaust pipe protector (stainless steel) G / (2) NPT / (2) M (2) vailable feature m vailable feature in D only - Not available * TEX solenoids are also approved according to EN 46- (non electrical valves) () Not to use with "SL" suffix (2) Provided with "SL" suffix ORDERING EXMPLES: SERIES PRODUT SELETION GUIDE STEP Select the fluid temperature range and seal material from the general table on page. Select basic catalogue number, including pipe thread identification letter. Refer to the specifications tables on page. Example: G STEP 2 Select (combination). Select the appropriate operator from the tables on pages and 0. Select for this operator in the electrical characteristics table on page : the power level (UP, LP), the type of electrical enclosure protection and the desired temperature class. Warning: The ambient temperature range of your application may not exceed the temperature range of your operator. Example : FS STEP Select suffix. Suffix MO mandatory for the pilot 02 (FSIS). Refer to the suffix table on page 0, respect the indicated power level. Example : MO STEP 4 Selection of TPL, on page, is mandatory for the 60 pilot (PISIS), 2 HV D (2 mw) and 24 HV D (2 mw). dd "X" between the "PISIS" and the basic catalogue number. STEP Select voltage. Refer to standard voltages on page. Example : 20V / 0Hz STEP 6 Final catalogue / ordering number. Example : FS GMO 20 V / 0 Hz FS G 20V / 0 Hz FS G SL 20V / 0 Hz FVT 20 MO 20V / 0 Hz PISIS G MO 6V / D PISIS G SLMO 6V / D PISIS X G 20 MS TPL HV / D G G GD G GDSL G 20 pipe thread basic number voltage TPL suffix ll leaflets are available on: /R0

11 EXPLNTION OF TEMPERTURE RNGES OF SOLENOID VLVES Valve temperature range Operator ambient temperature range Total temperature range The valve temperature range (TS) is determined by the selected seal material, the temperature range for proper operation of the valve and sometimes by the fluid (e.g. steam) The operator ambient temperature range is determined by the selected power level and the safety code The temperature range of the complete solenoid valve is determined by the limitations of both temperature ranges above ELETRIL HRTERISTIS oil insulation class F Electrical safety IE Standard voltages D (=) FS/ FVT: 24V FSIS: 2V - 24V ; PIS: 24V à 70V ; PISIS: 6V, V, 2V, 24V (~) FS: 24V - V - 20V/0Hz - Other voltages are available on request PIS: 24V to 70V power ratings operator electrical ambient replacement coil inrush holding hot/cold temperature enclosure safety code option range (TS) protection type ~ ~ = ~ = () (V) (V) (W) (W) ( ) (EN 602) - - Low power (LP) FS,4,2, /,2-2 to +60 EN 6070 moulded IP FS 2, (6),6 (6), (6) - -2 to +60 EN 6070 moulded IP FVT () - - -,/, -2 to +60 EN 6070 moulded IP67/IP FSIS ()(4) , -0 to +40/60 II G Ex ia II T6/T4, II D Ex iad 20 moulded IP Ultra low power (UP) PIS ,007-0 to moulded IP PISIS (2)() 6V ,00-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP PISIS (2)() V , to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP PISIS (2)() 2LV ,02-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP PISIS (2)() 2HV ,02-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP PISIS (2)() 2LV , to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP PISIS (2)() 2HV ,2-20 to +0 II G Ex ia II T6, II D Ex iad 20 moulded IP Not available () Refer to the dimensional drawings on pages 2 and. (2) Piezotronic standards voltages: Prefix PISIS: 6 V D / mw V D / 22 mw 2L V D / 2 mw 2H V D / 2 mw 24L V D / 46 mw 24H V D / 2 mw Turn ON voltage U ON 6.. V 7,2.. 2 V 0,.. 6 V 0,.. 6 V 2,6.. 2 V 2,6.. 2 V Turn OFF voltage U OFF V,2 V, V, V V V Peak current 6 m 0 m 6, m, m 0 m 4 m Holding current 0, m 2, m m 2,7 m, m,2 m able + max. barrier resistances (R S + R ) 200 Ω max. 00 Ω max. 200 Ω max. 470 Ω max. 200 Ω max. 470 Ω max. safety parameters () Intrinsically safe pilots: heck the electrical characteristics in the corresponding catalogue pages (FSIS: option U I I I P I L I I = (D) (V) (m) (W) (H) (µf) Low power (LP) FSIS 2 00,6 0 0 Ultra low power (UP) PISIS , pilot / PISIS: 60 pilot). (4) FSIS (02 pilot): 2 V : I (ON) min., with LED = m; U (ON) min.=, V; U (max.) recommended = 2 V; U (OFF) =, V; I (OFF) = 0 m 24 V : I (ON) min., with LED = 2 m; U (ON) min.= 6,4 V; U (max.) recommended = 2 V; U (OFF) =,7 V; I (OFF) = 7 m () Values for LED + protection. (6) : 20 V - Not available ELETRIL ONNETIONS connection Spade plug connector with cable gland DIN 460,,4 mm, industry standard, for cables with an outer diameter FS, FSIS, PIS, PISIS from 4 to 6 mm FVT M2 connection for M2 connector DDITIONL OPTIONS TPL numbers: TPL 2066: Piezotronic, PISIS, 2 HV (2 mw) TPL 20666: Piezotronic, PISIS, 24 HV (2 mw) TPL numbers: TPL 20674: LED and protection, FS - dd 0, W (D) and 0,4 W/V () Only available in 24 V /D and V Mounting on aluminium supply rail, /4 or /2 Other pipe threads are available on request INSTLLTION SERIES Installation/maintenance instructions are included with each valve The solenoid valves and air operated valves can be mounted in any position without affecting operation IE 60 Functional Safety (Suffix SL), allowable temperature range: -40 to +60. Probability of failure on demand, contact us It is necessary to connect pipes or fittings to the exhaust ports to protect the internal parts of the spool valve and its pneumatic operator if used outside or in harsh environments (dusts, liquids etc.) Threaded pipe connection identifier is: = NPT (NSI.20.); G = G (ISO 22/) Valves with suffix "SL" are provided with a specific exhaust protector ll leaflets are available on: /R0

12 SERIES DIMENSIONS (mm), WEIGHT (kg) Type 0..06: NOMO (E N) Type 07: ir operated 6,6 72, , 4 2 4, , 7, x G/4 2 mounting holes. mm dia.; Spotfacing: mm dia., depth mm G/ 2 2, x G/4 27, 4 TYPE 0: FS 02 pilot Polyarylamide IE / DIN 460 TYPE 02: FVT 02 pilot Polyarylamide IE / connection M2 + LED and protection / 20 MS / 20MS / MO / 20MO 2 / 20 MS / 20MS / MO / 20MO 2 20 M ,, 74,6 6 M , 27,,6 MO / 20MO TYPE 04: FSIS 02 pilot Polyarylamide IE / DIN 460 EN/IE 6007-/26 and EN/IE 624- MO / 20MO TYPE 06: PIS / PISIS Piezotronic pilot Polyamide IE / DIN 460 EN 6007-/26 and EN M ll leaflets are available on: 27, M /R0 --2

13 SERIES DIMENSIONS (mm), WEIGHT (kg) TYPE 07: ir operated version No Use "SL", "GD" or "GDSL" suffix IP6 / II GD c / 20 onnector rotatable by 0 increments (cable 4-6 mm) type option power level weight () monostable bistable 0 FS low power 0,66,7 02 FVT low power 0,66,7 04 FSIS low power 0,7, 06 PIS / PISIS ultra low power 0,, ,4,07 () Incl. connector(s), except FVT. ESSORIES 7, 2 onnector rotatable by 0 increments (cable 6-7 mm) Manual operator location onnectable pilot exhaust port Ø Ø M - /4 4, - exhaust protector (stainless steel) ll leaflets are available on: 20/R0 --

14 SERIES ll leaflets are available on: PI-0-00-G -- vailability, design and specifications are subject to change without notice. ll rights reserved. 20/R0

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NMUR style, / - / 0 / / Series - FETURES The monostable spool valves in conformity with IE 608 Standard

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 - / FETURES The monostable spool valves in conformity with IE 508 Standard (00 route H version)

More information

SOLENOID VALVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLENOI VLVES solenoid air pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, / - / FETURES The monostable spool valves in conformity with IE 608 Standard (00 route

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NAMUR style, 1/4-1/2 SOLENOI VLVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, NMUR style, / - / 0 / / Series - FETURES The monostable spool valves in conformity with IE 08 Standard

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, /4 - / N 0 / Series 55 55 FTURS The monostable spool valves in conformity with I 650 Standard

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function, W/W) stainless steel body, /4 - /2 4 4 2 2 4 4 2 4 4 2 2 4 4 2 2 2 /2 / Series - FTURS The monostable spool valves

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) aluminium body, /4 - / FTURS The monostable spool valves in conformity with I 650 Standard (00 route H version) have

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 FTURS The monostable spool valves have TÜV-XID certified I 60 Functional Safety data and can be used up to SIL 4 (/TÜV)-SIL (/XID) The / and / solenoid operated spool valves have threaded port connections

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function, W/W) aluminium body, /4 - /2 4 4 2 2 4 4 2 4 4 2 2 4 4 2 2 2 /2 / Series - FTURS The monostable spool valves in conformity

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) stainless steel body, 1/4-1/2 FTURS The monostable spool valves in conformity with I 60 Standard (200 route 2 H version) have TÜV ( series) and XID (- series) certified with integraty levels: SIL 2 for HFT = 0 / SIL for HFT = The /2

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4 to 1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function, W1/W3) aluminium body, 1/4 to 1/2 FTURS The monostable spool valves have TÜV-XID certified I 60 Functional Safety data and can be used up to SIL 4 (/TÜV)-SIL (2-/XID) The spool valves /2 and / have threaded port connections ll the exhaust

More information

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2

SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4-1/2 SOLNOID VLVS pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, /4 - / 4 4 / Series FTURS Series monostable spool valves /4 have TÜV certifi ed I 60 Functional

More information

GENERAL AIR OPERATED SPECIFICATIONS PILOT OPERATED SPECIFICATIONS. Series /8 = 3000 l/min 1/2 = 3800 l/min

GENERAL AIR OPERATED SPECIFICATIONS PILOT OPERATED SPECIFICATIONS. Series /8 = 3000 l/min 1/2 = 3800 l/min SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, /4 to / 0 / 0 Series 55 55-55 FTURS The monostable spool valves, series 55, have

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, 1/4 to 1/2 SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid or air (mono/bistable function) aluminium body, /4 to / 0 0 / Series 55 55-55 TURS SCO/JOUCOMTIC solenoid valves satisfy all relevant

More information

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid aluminium body, 1/4 to 1/2

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid aluminium body, 1/4 to 1/2 FTURS SPOOL VLVS pilot operated or air operated, spool type single/dual solenoid aluminium body, / to / SCO/JOUCOMTIC solenoid valves satisfy all relevant C irectives The monostable spool valves, series,

More information

SOLENOIDS, COILS & ACCESSORIES Product Index

SOLENOIDS, COILS & ACCESSORIES Product Index SOLENOIDS, COILS & ACCESSORIES Product Index Description Series Page Coil identification Catalogue numbers of replacement coils SOLENOID OPERATORS Solenoid s, description and dimensions V1100-2/3 V1100-4..6

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

24000, 3/2 Direct solenoid actuated direct poppet valves

24000, 3/2 Direct solenoid actuated direct poppet valves > > Port size: G/4... G / > > Working from 0 bar up > > Suitable for vacuum range down to, 0 - mbar l/s > > 65, Ex em, Ex d (TEX approved, see solenoid operators) > > Suited for outdoor installation Technical

More information

2/2-Way Solenoid Control Valve

2/2-Way Solenoid Control Valve 2/2-Way Solenoid Control Valve Excellent range (1:200) Very good response Compact valve design Orifice sizes 0.8... 4 mm Port connection 1/8, 1/4 or sub-base Type 2873 can be combined with Type 8605 Digital

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

2-way pilot operated solenoid valves for water, hot water and steam

2-way pilot operated solenoid valves for water, hot water and steam 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8658/GB NEW Also available with ATEX Explosion-proof electrical parts Technical specifications General description Applications

More information

Resistance Thermometers Model Series TR7X0, Sheathed Design

Resistance Thermometers Model Series TR7X0, Sheathed Design Electrical Temperature Measurement Resistance Thermometers Model Series TR7X0, Sheathed Design WIKA Data Sheet TE 60.40 Applications T Suitable for all industrial and laboratory applications Special Features

More information

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5. General data Mounting On linear actuators On quarter turn actuators ARCA-integrated or to VDI/VDE 3847-1 or IEC 534-6 (NAMUR) Range of stroke: 3... 130 mm Integrated to VDI/VDE 3847-2 or VDI/VDE 3845 Angle

More information

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm

T11 - T12 - T13. Electrical contacts stainless steel thermometers. Specifications (20 C) Ø Ø Ø 160 mm Electrical contacts stainless steel thermometers T11 - T12 - T13 Ø - Ø 1 - Ø 160 mm Derived from the TX thermometers of nominal diameter, 1 and 160, of which they possess all the characteristics, the T11,

More information

DPharp Differential Pressure and Pressure Transmitters

DPharp Differential Pressure and Pressure Transmitters User s Manual DPharp Differential Pressure and Pressure s Manual Change No. 12-021-2 For the products of EJX and EJA-E series with any of the following option codes, please refer to this manual change

More information

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE

TLR wire System Level Radar. MICROWAVE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Level Radar TLR3000 MICROWAVE level meter GENERAL The TLR3000 is a non-contact type continuous level meter using microwaves. It detects a level by measuring a reciprocating time of a microwave

More information

Products catalogue (I-P Edition)

Products catalogue (I-P Edition) Products catalogue (I-P Edition) Products catalogue (I-P Edition) FROM QUALITY OUR NATURAL DEVELOPMENT Active in the industry of Refrigeration and Air Conditioning for fifty-five years, Castel is well-established

More information

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator ANSI version Application Control valves designed for mechanical and plant engineering. Suitable for liquids, gases and steam

More information

IP26 Series Current to Pneumatic Converter

IP26 Series Current to Pneumatic Converter Product Specifications 06.2016 PSS EVE0403 A-(en) IP26 Series Current to Pneumatic Converter The IP26 (current to pressure) transducer converts a 4 20mA electrical current signal to a proportional linear

More information

FAS 10 mm PICOSOL Direct acting solenoid valve

FAS 10 mm PICOSOL Direct acting solenoid valve FS 0 mm PICOSOL > > /, /; Manifold mounting > > Long life 00 million cycles > > Compact Design > > Low power consumption Technical features Medium: ir, oxygen, neutral gases (0 %... 9 % humidity, non condensing),

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.*

Cable Glands, Metal, for shielded EMC Cables CG.EM.*.*.* Features Assembly Cable gland series for shielded EMC cables Brass nickel-plated or stainless steel AISI 316 Suitable for operation in Zones 1, 2, 21 and 22 Certified Ex d, Ex e and Ex tb Metric and NPT

More information

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Data Sheet MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400 Submersible Hydrostatic s Rugged and versatile We reserve the right to continuously improve our products and make any change in

More information

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Data sheet Intrinsically safe pressure transmitter MBS 420, MBS 425, MBS 470 and MBS 475 The intrinsically safe pressure transmitter program is designed for use in hazardous environments and offers a reliable

More information

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE

TGR wire System Guided Radar Gauge. MICRO-PULSE level meter GENERAL FEATURES OPERATION PRINCIPLE 2-wire System Guided Radar Gauge TGR3000 MICRO-PULSE level meter GENERAL TGR3000 series is the 2-wire system Guided Radar Gauge which can continuously measure the level using micro-pulse. The micropulse

More information

Design and applications

Design and applications Design and applications The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is calibrated

More information

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request

Euromas Polymas. Colour: Silver grey, similar to RAL 7001; special colours on request Euromas Polymas Detailed product information can be found on www.bopla.de - 5 sizes - Versions with or without screwing systems - Quick-release fastener versions - Transparent lids on request - Terminals

More information

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas Mimablad: 176GB/1999-10-25 Ersätter: MG-1000-EEx USAGE MG-1000-EEx is suitable for use in measurement

More information

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - # Solenoid coil MKY/18x60 For explosion-hazard zones Protection class IP65/66/67 Optional with integrated amplifier electronics Ex db IIC T6 / T4 Gb Ex tb IIIC IP65 T80 C/T130 C Db Ex db I Mb II 2 G Ex db

More information

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg.

3 & 4 Wire Self Compensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. & 4 Wire Self ompensating Ultrasonic Transmitters - Standard Mtg.& Sanitary Ferrule Mtg. FETURES S.S. 1L Face Material c/w Tri-lamp Mtg. Base Simple push-button calibration (ccurate) Output 4-20 m / 20-4

More information

Resistance thermometers for process technology

Resistance thermometers for process technology Data Sheet 90.2820 Page 1/8 Resistance thermometers for process technology for temperatures from -200 to +600 C with protection tubes in stainless steel, titanium, tantalum, Iconel and Hastelloy available

More information

Rod probe With coaxial tube reference probe

Rod probe With coaxial tube reference probe Capacitive level transmitters GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y RA 9 /6.98 -Way Proportional Logic Cartridge Valve Model FE.. (Series X and X) Size 6... 6... 6 PSI (5 bar)... 75 GPM (8 L/min) RA 9 /6.98 Replaces: 5.9 Characteristics: Single land throttle valve (main

More information

Directional valves Electrically operated Series 563, 565, 567. Brochure

Directional valves Electrically operated Series 563, 565, 567. Brochure Directional valves Electrically operated Brochure 2 Directional valves Electrically operated 3/2-directional valve, Series 563 Qn = 1350 l/min plate connection Electr. connection: Plug, Form B, industry

More information

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet Specification Sheet 600T Series Transmitters Model 65L Electronic temperature transmitter (PC programmable for RTD and resistance) High flexibility and wide rangeability Primary element and calibration

More information

SALES SERVICE +358 (0)

SALES SERVICE +358 (0) SALES SERVICE +358 (0)17 262 3555 info@econosto.fi ADCATROL ELECTRO-PNEUMATIC POSITIONERS PE 986 (ATEX) DESCRIPTION The ADCATROL PE986 positioner requires an input signal of 4 20 ma for proportional control

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023137 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

Precision Junction Boxes

Precision Junction Boxes Precision Junction Boxes Accuracy and Stability All components are designed for high accuracy and long term stability. Precision SMT resistors and gold plated switches guarantee trouble free operation.

More information

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc

F780HD, 3, 3-Way Butterfly Valve Resilient Seat, 304 Stainless Steel Disc F80HD, 3, 3-Way utterfly Valve Resilient Seat, 304 Stainless Steel Disc pplication Valve is designed for use in NSI flanged piping systems to meet the needs of bi-directional high flow HV hydronic applications

More information

VITO LT. Global Experience. Locally Applied. A dependable choice.

VITO LT. Global Experience. Locally Applied. A dependable choice. VITO LT A dependable choice. your accuracy requirements for tank inventory. Global Experience. Locally Applied. The VITO LT probe belongs to the VITO family for temperature and water bottom measurement.

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC300 5/271. Overview. Configuration Siemens G 200 Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D

EN 1092 PN 10 EN 1092 PN 16 JIS B K ANSI B16.5 Class 150 ANSI B16.47 Class 150 BS 10 Table D HG EN 1092 PN 10 EN 1092 PN 16 JIS 2238 10K ANSI 16.5 Class 150 ANSI 16.47 Class 150 S 10 Table D Stafsjö s knife gate valve HG is a bi-directional valve, particularly well suited for severe operating

More information

4CONTROL VALVES CONTROL VALVES ULTRAFLO BUTTERFLY VALVES 522 SERIES NEW! H2X E2X KMSC-0 SPECIFICATIONS

4CONTROL VALVES CONTROL VALVES ULTRAFLO BUTTERFLY VALVES 522 SERIES NEW! H2X E2X KMSC-0 SPECIFICATIONS SERIES DESRIPTION The Series resilient seated butterfly valves are available in "-0" sizes. Economical and designed to meet todayʼs HV and industrial process requirements, they come standard with full

More information

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem

B350L, 3-Way, Diverting Ball Valve Chrome Plated Brass Ball and Nickel Plated Brass Stem B350L, 3-Way, Diverting Ball Valve hrome Plated Brass Ball and Nickel Plated Brass Stem pplication This valve is typically used in air handling units on heating or cooling coils, and fan coil unit heating

More information

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F

Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F, IS-21-F Replacement product: Model IS-3 Electronic Pressure Measurement Intrinsically Safe Pressure Transmitter for applications in hazardous environments and shipbuilding industry Model IS-20-S, IS-21-S, IS-20-F,

More information

PAD - Heavy Duty Differential Pressure Trasmitter

PAD - Heavy Duty Differential Pressure Trasmitter Benefits and Features Span: 0.3" W.C. 6" W.C. to 60 6000 PSIG Static Pressure: Max. 4500 PSIG t max : 248 F Process Connection: ½" NPT, ¼" NPT, or Various Diaphragm Seals Available upon Request Material:

More information

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING Technical leaflet 2 RD.5G.H4.02 Danfoss A/S (IC-MC/mr), 09-2004 Introduction AKS 32 and AKS 33 are pressure transmitters that

More information

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With Field-mounted Two-wire Signal Conditioners B6-UNIT 8: TIIS flameproof (CE not available) Confirm selectable combinations of approval and wiring conduit types in the table. 2-WIRE UNIVERSAL TEMPERATURE

More information

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm Electronic pressure measurement Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm WIKA data sheet PE 86.05 Applications Process technology Machine building and plant

More information

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description

BAR-ANT-N-N-EX. Antenna barrier for the hazardous area. Data sheet. 1 Description BAR--N-N-EX Antenna barrier for the hazardous area Data sheet 060_en_00 PHOENIX CONTACT 05-06-0 Description Using an antenna barrier, you can execute HF outputs of wireless modules with intrinsic safety.

More information

Field indicator for current loops with HART communication Models DIH50, DIH52

Field indicator for current loops with HART communication Models DIH50, DIH52 Accessories Field indicator for current loops with HART communication Models DIH50, DIH52 WIKA data sheet AC 80.10 for further approvals see page 6 Applications Process engineering Plant construction General

More information

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS

SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS SOLENOID TYPE, CERTIFICATION & PROTECTION CONCEPTS Highlights in this presentation. 1. Have received BIS Approval for 62, 66, 67, 67L, 71 & 71L. 2. CCOE for the same is under process. 3. UL 1203 Approval

More information

ED701 General Industry Pressure Transmitter

ED701 General Industry Pressure Transmitter ED701 General Industry Pressure Transmitter Standard industrial process connections Complete range of electrical connections 4... 20 ma and Voltage outputs Accuracy: 0.1%, 0.2% and 0.4% FS Quick response

More information

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 060R9345 Instructions Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751 Content Page 1 Description/application 2 Identification 3 Specifications 4 Safety instructions 5 Installation/dimensions

More information

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd

Level Measurement. Continuous level measurement Capacitance transmitters SITRANS LC300. icenta Controls Ltd Overview onfiguration Installation uild up of material in active shield area does not affect switch operation. Mounting on a bypass is an inverse frequency shift capacitance continuous level transmitter

More information

NEW. 7321B 7322B Series. 2-way pilot operated solenoid valves for water, hot water and steam

NEW. 7321B 7322B Series. 2-way pilot operated solenoid valves for water, hot water and steam 7321B 7322B Series 2-way pilot operated solenoid valves for water, hot water and steam Catalogue 8659/GB NEW Also available with ATEX G & D Explosion-proof electrical parts Technical specifications General

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable) Specification Sheet 600T Series Transmitters Model 65T Electronic temperature transmitter (PC programmable) High flexibility and wide rangeability Single transmitter accepts RTD/THC/mV/ohm Galvanically

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted Electrical temperature measurement Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted WIKA data sheet TE 60.34 Applications Machine building, plant and vessel construction

More information

OPTIWAVE 7300 C Supplementary instructions

OPTIWAVE 7300 C Supplementary instructions OPTIWAVE 7300 C Supplementary instructions Radar (FMCW) Level Transmitter for agitated liquids in process applications Supplementary Instructions for ATEX applications KROHNE CONTENTS OPTIWAVE 7300 C General

More information

Power supply. Calibration. Surface finishing. Seal. Process connection

Power supply. Calibration. Surface finishing. Seal. Process connection Page 1 of 6 Description The measuring system is designed for flow measurement. Gas flow through the sensing section passes two PT 100 RTD transducers; one is used as a temperature sensing device whilst

More information

Process Protection Acoustic sensors for pump monitoring

Process Protection Acoustic sensors for pump monitoring coustic sensors for pump monitoring acoustic diagnostic unit Overview The acoustic diagnostic unit acoustically measures the structure-borne noise In the version for pump monitoring; on oscillating displacement

More information

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted Electrical temperature measurement OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted WIKA data sheet TE 60.31 further approvals see page 10 Applications Machine building, plant

More information

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output. GENERAL INFORMATION T6000 SERIES TRANSDUCER Electro-Pneumatic (I/P, E/P) APPLICATIONS The T6000 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional

More information

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available)

MODEL: 27HU-B 27-UNIT. [3] LED INDICATOR 0: Without 1: With (SIL not available) MODEL: 7HU- Head-mounted Two-wire Signal Conditioners 7-UNIT -WIRE UNIVERSL TEMPERTURE TRNSMITTER (HRT communication, outdoor enclosure, explosion-proof) Functions & Features Universal input: DC mv, T/C,

More information

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters ll 2G EEx ia llc T6 As our products are continuously improved, we reserve the right to make any change in the stated specifications

More information

CombiTemp TCR6 Standard RTD temperature sensor

CombiTemp TCR6 Standard RTD temperature sensor Main features Sensor and connection in stainless steel, ISI 6 DIN form B housing Robust design pplications Industrial applications with industrial process connection Pipe systems Heating systems Water

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Pressure measurement PBMR Fully welded pressure transmitter for railway applications

Pressure measurement PBMR Fully welded pressure transmitter for railway applications Fully welded pressure transmitter for railway Product highlights Ecellent accuracy and long term stability up to % FS Active temperature compensation over the entire operating temperature range Sensor

More information

General Specifications

General Specifications General Specifications YTA110 Temperature Transmitter [Style: S] The YTA110 is the high performance temperature transmitter that accepts Thermocouple, RTD, ohms or DC milivolts inputs and converts it to

More information

Resistance thermometer Model TR30, compact design

Resistance thermometer Model TR30, compact design Electrical temperature measurement Resistance thermometer Model TR30, compact design WIKA data sheet TE 60.30 Applications Machine building, plant and vessel construction Propulsion technology, hydraulics

More information

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations. EATON 2.4.1

CEAG Products Main Catalogue Part 2: Chapter Ex-Control units and control stations.  EATON 2.4.1 CEAG Products Main Catalogue Part : Chapter... Ex-Control units and control stations www.crouse-hinds.de EATON.. .. EATON www.crouse-hinds.de Ex-Control units and control stations Table of contents. GHG

More information

INSTRUCTION MANUAL (ATEX / IECEx)

INSTRUCTION MANUAL (ATEX / IECEx) INSTRUCTION MANUAL (ATEX / IECEx) STExS1 & STExS2 Sounder For use in Flammable Gas and Dust Atmospheres 1) Warnings DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT POTENTIAL ELECTROSTATIC CHARGING

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013

4-Way Servo Valve Model 4 WS. 2 E , (Series 2X) with Mounting Pattern to DIN or CETOP RP 115 H PSI (315 bar) H/A 3012 H/A 3013 4-Way Servo Valve Model 4 WS. 2 E. 16..., (Series 2X) with Mounting attern to DIN 24 3 or CETO R 11 H Size 16... 40 SI (31 bar)... 3 GM (0 L/min) R 29 91/06.98 R 29 91/06.98 Replaces: 0.94 2 stage servo

More information

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004 Single-Channel Safety Barriers with Electronic Current Limitation > Broad product range for all standard applications in the world of automation > Flexible and space saving > Time saving installation due

More information

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12 EB-20023139 Revision: AA Number of Pages: 13 Comments: Originator: RCS 10/05/12 Approved: RCS 10/05/12 Rev ECN Description Approval Date AA 1049085 Release to Approvals RCS 10/9/12 Micro Motion, Inc. Page

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

SATRON VB Pressure Transmitter

SATRON VB Pressure Transmitter SATRON VB pressure transmitter belongs to the series V transmitters. SATRON VB is userfriendly, through the ball valve mounted transmitter which is used for 04 kpa... 03 MPa ranges. The transmitter communicates

More information