The transducer component converts the measured signal and displays the actual value.

Size: px
Start display at page:

Download "The transducer component converts the measured signal and displays the actual value."

Transcription

1 Digital inductive conductivity transmitter System Integration Provides low Total Cost of Ownership PEEK/PPA version for CIP applications TEACH IN and SIMULATION Function Approval PVDF Version PEEK Version This conductivity transmitter compactly combines a conductivity sensor and a transmitter with a display in a splash-proof plastic NEMA 4 enclosure. The sensor component consists of a pair of magnetic coils in a PVDF or PEEK enclosure. In order to measure conductivity, an AC voltage source is connected to the primary magnetic coil. The magnetic field induced generates a current in the secondary magnetic coil. The intensity of the induced current is a direct function of the conductivity of the solution. The temperature sensor for automatic compensation is a standard feature in the sensor housing. The transducer component converts the measured signal and displays the actual value. The transducer Type 8226 functions in a 3 wire circuit and requires a power supply of VDC. A 4 20mA standard signal is available as output signal, proportional to the conductivity or the temperature of the fluid. The setpoint values of the relays are freely adjustable. A wide range of stainless steel, brass and plastic fittings available (see corresponding ordering data). A remote mount version is available upon request. Technical data Conductivity measurements Conductivity measurements Waste engineering Contaminated liquids Liquids with particles Liquids with coating and sealing build up Clean in place (CIP) usa.com Page /11

2 The easy conductivity control system ON / OFF Process Control Description: ON / OFF Valve Relays 8226 Transmitter Applications: Neutralization Dosing Waste Water Processing Relays Continuous Process Control Description: Continuous Control Valve 4 20 ma 8226 Transmitter Applications: Water Monitoring Continuous Chemical Dosing Waste Water Treatment Design This conductivity measuring system is available as a compact version Type The cell constant is an average value over the whole measuring range. It can be readjusted depending on application. The temperature sensor for automatic compensation is a standard feature in the conductivity sensor housing. The 8226 inductive conductivity transmitter output signal is a standard 4 20 ma signal. Optional with two freely adjustable relay outputs. Principle of operation The conductivity is defined as the ability of a solution to conduct electrical current. The load carriers are ions (e.g. dissolved salts or acids). In order to measure conductivity, an AC voltage source is connected to the primary magnetic coil. The magnetic field induced generates a current in the secondary magnetic coil. The intensity of this induced current is a direct function of the conductivity of the solution. The transmitter comes without relays or with 2 relays functions in a 3 wire circuit. Limit values are freely adjustable. Page /11

3 Installation The inductive conductivity transmitter Type 8226 is mounted in vertical position (max. ±90 ) into a horizontal pipe. 90ϒ The inductive conductivity transmitter 8226 can be easily installed into pipes using our specially designed fitting system: 1. The fitting must be installed into the pipe according to the installation specifications. 2. Insert plastic nut into fitting and let plastic ring snap into guide bush. 3. Carefully insert transmitter 8226 into fitting. If installed properly, the transmitter cannot be rotated. 4. Tighten transmitter housing to fitting with plastic nut. The device must be protected against constant heat radiation and other environmental influences, such as magnetic fields or direct exposure to sunlight. Important! When mounted, the transmitter has to be turned by 90 The device can be mounted in following positions: Horizontal or vertical Mounting in tank without mixer Mounting in tank with mixer Pressure Temperature Diagram (plastic fittings): Fluid pressure (PSI) PVDF PVC + PP Application range for complete device (fitting + transmitter) PVC PVDF 14.5 PP Fluid temperature ( F) Pressure Temperature Diagram (metal fittings): Fluid pressure (PSI) Application range for complete device (fitting + transmitter) stainless steel / brass Fluid temperature ( F) Page /11

4 Operation / commissioning The operation of the conductivity transmitter is classified in the following 3 different menus: Main menu Conductivity Temperature Output current HOLD function Calibration menu Language Engineering units Cell constant Temperature compensation Measuring range 4 20 ma Relay function Filter selection Test menu Offset Span Conductivity non compensated Simulation of conductivity Display type digits alphanumeric Description of buttons Acceptance of chosen parameter or adjusted value LED relay 2 (contact closed) LED relay 1 (contact closed) Direction downwards in menu or sidewards for digit selection Display selection and increasing key (numeric values) impulses or automatic Page 4/11

5 Installation Technical data Pipe size Measuring range Conductivity Resistivity 1 1/4" 4" (DN32 DN100) 100 µs/cm... 2 S/cm 0.5 Ω cm kω cm Measuring error ±2% of measured value Repeatability < 0.4% of measured value Temperature compensation Automatic with standardized integrated temperature sensor with reference temperature 77 F (25 C) Fluid temperature 32 F to 248 F (0 C to 120 C) (depending on fitting, see Pressure Temperature Diagram) Ambient temperature 32 F to 140 F (0 C to 60 C) Storage temperature 32 F to 140 F (0 C to 60 C) Fluid pressure (depending on temperature, see Pressure Temperature Diagram) Pressure class 87 PSI Enclosure NEMA 4 (IP 65) Relative humidity max. 80% Electronic housing PC (for PVDF housing) reinforced with 20% glass fiber PPA (for PEEK housing) reinforced with 33% glass fiber Sensor housing PVDF or PEEK O rings FKM or EPDM Voltage supply V/DC Consumption 12 V/DC 24 V/DC Analog output signal Load Relay output (optional) Max. 70 ma (without relais) Max. 150 ma (with relais) Max. 70 ma (without relais) Max. 150 ma (with relais) 4 20 ma programmable, proportional to the conductivity or temperature <1000 Ω at 30 V < 800 Ω at 24 V < 450 Ω at 15 V < 330 Ω at 12 V 2 relays, 3 A / 230 V; freely adjustable Dimensions [inch (mm)] Conductivity Transmitter Type 8226 Compact 4.96 (126) 4.06 (103) PVDF: 7.40 (188) PEEK: 7.48 (190) 4.17 (106) NPT 1/ (88) PVDF: 7.40 (188) PEEK: 7.48 (190) 4.17 (106) NPT 1/ ENTER 0 9 REL 1 REL ENTER 0 9 REL 1 REL (88) 3.46 (88) 3.46 (88) Page /11

6 Dimensions [mm] fitting S020, 1 1/4" 2" (DN 32 50) for transmitter 8226 Variable Dimensions [mm] Port (DN) H 1 1/4 (32) /2 (40) (50) H Applicable for all fitting materials 1 1/4" to 2" (DN 32 50) process connections. True Union PVC, PP, PVDF øc øa B L1 L3 L Compact Version Dimensions [mm] True Union Port (DN) B A L C L1 L3 DIN ASTM DIN ASTM 1/14" (32) /2" (40) " (50) Page 6/11

7 Dimensions [mm] fittings S020, 1 1/4" 2" (DN 32 50) Female Threaded Port - Stainless Steel / Brass M K N H G1 L1 C Material Stainless Steel: DIN ; BS 316L Flange - Stainless Steel* Tri-Clamp** (European Standard) Connection acc. ISO 2852 J Material: B.S. 316 L I E Material: B.S. 316 L D DIN 3202-F1 * Flange: ANSI B , length according to DIN 3201 F1 ** U.S. Tri Clamp available upon request Compact Version Dimensions [mm] Port (DN) Length Dimensions Thread Tri Clamp Flange Dimensions C D E G1 L1 H Norm* I J K M N 1/14" (32) NPT 1 1/ ANSI X /2" (40) NPT 1 1/ ANSI X " (50) NPT ANSI X Page 7/11

8 Dimensions [mm] fitting S020, 2 1/2" 4" (DN ) Weld o Let Fittings with Radius Stainless Steel Material: 316L (B.S.) Variable Dimensions [mm] Pipe (DN) A R 2 1/2 (65) " (80) " (100) Weld o Let Fittings PE, PP, PVDF* Variable Dimensions [mm] (DN) A PE PP PVDF B C B C B C B C *For metric pipe only. Weld o Let Fittings for Side Wall Mounting Page 8/11

9 Ordering chart for inductive conductivity transmitter 8226 PVD versions Conductivity transmitter compact 4 20mA output; without relays Description Gasket Electrical connection Voltage Item No. FKM FKM Conduit plug NPT 1/2 2x Conduit Entry NPT 1/ VDC VAC P R Conductivity transmitter compact 4 20mA output; with 2 relays Description Gasket Electrical connection Voltage Item No. FKM FKM 2x Conduit entry NPT 1/2 2x Conduit entry NPT 1/ VDC VAC K V PEEK versions Conductivity transmitter compact 4 20mA output; without relays Description Gasket Electrical connection Voltage Item No. EPDM EPDM Conduit plug NPT 1/2 2x Conduit entry NPT 1/ VDC VAC G W Conductivity transmitter compact 4 20mA output; with 2 relays Description Gasket Electrical connection Voltage Item No. EPDM EPDM 2x Conduit entry NPT 1/2 2x Conduit entry NPT 1/ VDC VAC X Y Accessories Conductivity buffer solutions traceable to NIST Description Conductivity buffer solution 5 µs/cm ; 300 ml Conductivity buffer solution 15 µs/cm ; 300 ml Conductivity buffer solution 100 µs/cm ; 300 ml Conductivity buffer solution 706 µs/cm ; 300 ml Conductivity buffer solution 1413 µs/cm ; 300 ml Conductivity buffer solution 100 ms/cm ; 300 ml Item No Z S T C D A Page 9/11

10 Ordering data for plastic fittings Type S020 Diameters Materials Item No. PP True Union with Metric Weld Ends DN 32 PP, FKM U DN 40 PP, FKM V DN 50 PP, FKM W PP Weld o Let DN PP L PVDF True Union with Weld Ends DN 15 PVDF, FKM S DN 40 PVDF, FKM H DN 50 PVDF, FKM A PVDF Weld-o-Let DN PVDF Q Diameters Materials Item No. PVC True Union ASTM 1 1/4" PVC, FKM W 1 1/2" PVC, FKM X 2" PVC, FKM Y PE Weld o Let DN PE G Ordering data for stainless steel fittings S020 Ordering data for brass fittings Type S020 Diameters Materials Item No. SS Female NPT Threaded Ports 1 1/4" SS, FKM H 1 1/2" SS, FKM A 2" SS, FKM B SS European Tri Clamp (ISO 2852) DN 32 SS, FKM R DN 40 SS, FKM N DN 50 SS, FKM B SS ANSI Flanges (ANSI B ) 1 1/4" SS, FKM W 1 1/2" SS, FKM X 2" SS, FKM Y SS Weld-o-Let 2 1/2" SS M 3" SS N 4" SS P Diameters Materials Item No. Brass Female NPT Threaded Ports 1 1/4" Brass, FKM Z 1 1/2" Brass, FKM S 2" Brass, FKM T SS Weld-o-Let for Side Wall Mounting SS R Page 10/11

11 Technical data ON/OFF Control -50% ON/OFF Control -50% Continuous Control -60% In case of special application conditions, We reserve the right to make technical 0703/2_US-en_ please consult for advice. changes without notice. Page 11/11

Digital inductive conductivity transmitter

Digital inductive conductivity transmitter Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Digital conductivity transmitter

Digital conductivity transmitter Digital conductivity transmitter Compact version with integrated conductivity electrodes Remote version with seperated transmitter for short (15 ft.) or long (1500 ft.) distance Commissioning is easy due

More information

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output Digital Inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections

More information

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display, DN 15 - DN 50; PN Advantages / Benefits Easy System integration by Easy LINK provides low cost of ownership Easy commissioning due to multi-language, menu-guided operation TEACH-IN: automatic calibration

More information

Electromagnetic Flow Transmitter

Electromagnetic Flow Transmitter Electromagnetic Flow Transmitter Sensor in solid state technology Working as a transmitter and/or as an On/Off controller Automatic-calibration of full scale: Teach-In Clean in place (CIP) Type can be

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement ELEMENT Transmitter Digital flow ELEMENT transmitter for continuous flow measurement Type can be combined with... PN10, DN15 to DN400 fluidic process connection Programmable outputs : one or two transistor

More information

Digital flow transmitter for continuous flow measurement

Digital flow transmitter for continuous flow measurement Digital flow transmitter for continuous flow measurement Compact or remote version for DN 06 to 400, PN10 Shows both flow rate and volume (with two totalizers) Automatic-calibration: TEACH-IN Simulation:

More information

INSERTION paddle wheel flowmeter for continuous flow measurement

INSERTION paddle wheel flowmeter for continuous flow measurement INSERTION paddle wheel flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both

More information

Valve Island with Electronic I/O

Valve Island with Electronic I/O Screw in Temperature /Switch with display for ON/OFF Control Indication, monitoring, transmission and ON/OFF control in one device Extra large display Menu guided parametrisation Complete communication

More information

Conductivity Transmitter

Conductivity Transmitter Conductivity Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

ph or ORP Transmitter

ph or ORP Transmitter ph or ORP Transmitter Programmable outputs: two transistor and single or dual analog 4-20 ma (Process + Temp) Removable backlighted display Universal process connection Compatible with 120 mm ph/ ORP probes

More information

Digital flow ELEMENT transmitter for continuous flow measurement

Digital flow ELEMENT transmitter for continuous flow measurement Digital flow ELEMENT transmitter for continuous flow measurement Type 8036 can be combined with... DN06 to DN65 fluidic process connection Programmable outputs : one or two transistor output(s) and single

More information

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module / - ; 0 PSI Advantages / Benefits Wireless easy mounting and dismounting of sensor head by a Turn & Lock technique 3-wire Hall version to interface directly with PLC's (both NPN and PNP) Easy to connect:

More information

Ultrasonic level transmitter, non-contact

Ultrasonic level transmitter, non-contact Ultrasonic level transmitter, non-contact Type 8175 can be combined with... Compact, remote versions for level measurement up to 10 m Multi language menu control Interference echo filter Automatic calibration:

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Paddle wheel flow controller for On/Off control

Paddle wheel flow controller for On/Off control addle wheel flow controller for On/Off control Type 8032 compact Type 8032 can be combined with... Type 8032 remote Indication, monitoring, transmitting and On/Off control in one device. rogrammable outputs

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

INLINE flowmeter for continuous flow measurement

INLINE flowmeter for continuous flow measurement INLINE flowmeter for continuous flow measurement Economic integration in pipe systems without any additional piping 3-wire frequency pulse version to directly interface with PLC s (both PNP and NPN) Connection

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/01.12 71195835 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application The compact measuring

More information

Insertion Flow sensor for continuous flow measurement

Insertion Flow sensor for continuous flow measurement Insertion Flow sensor for continuous flow measurement Economic integration into pipe systems 2 wire frequency coil (sinusoidal) version 3 wire frequency Hall effect (pulse) version to directly interface

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/02.14 71264779 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement 8025 Flowmeter INSERTION Digital flowmeter for continuous flow measurement Compact or remote version for DN06 to DN400, PN10 Displays both flow rate and volume (with two totalizers) On site calibration

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Indumax CLS50/CLS50D. Technical Information

Indumax CLS50/CLS50D. Technical Information Technical Information Indumax CLS50/CLS50D Inductive conductivity sensor for standard, hazardous and high-temperature applications, analog or digital with Memosens protocol Application Indumax CLS50/CLS50D

More information

Conductivity sensor for hygienic applications

Conductivity sensor for hygienic applications Conductivity sensor for hygienic applications 2- or 4-electrode technology Extended measuring range 0.05 S/cm... 500 ms/cm Process connections, materials, surface finish designed for use in hygienic applications

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Digital batch controller

Digital batch controller INSERTION Digital batch controller Type 8025 can be combined with... Compact or remote version for DN06 to DN400, PN10 Dosing On site calibration by Teach-In Check of input/output signals Total and daily

More information

Conductivity measurement SmarTec S CLD 132

Conductivity measurement SmarTec S CLD 132 Technical Information TI 207C/24/ae Conductivity measurement SmarTec S CLD 132 Transmitter for measurement of conductivity and concentration with inductive sensor Areas of application Alkali/acid concentration

More information

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0. Technical Information Condumax W CLS9 Conductivity sensors Two-electrode sensors with cell constants k = 0.0 cm or k = 0. cm Application Measurement in pure and ultrapure water: Monitoring ion exchangers

More information

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement Technical Information / Operating Instructions TI 281C/07/en/08.02 No. 51506567 SmarTec M Conductivity Measurement Compact conductivity transmitter with inductive sensor and integrated temperature compensation

More information

Technical Information Smartec CLD18

Technical Information Smartec CLD18 TI01080C/07/EN/03.16 71314717 Products Solutions Services Technical Information Smartec CLD18 Compact inductive conductivity measurement for the food and beverage industry Application Compact measuring

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Level gauges Series LT Level indicator, switch and transmitter for liquids

Level gauges Series LT Level indicator, switch and transmitter for liquids Level gauges Series LT Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Excellent chemical resistance

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview Siemens AG 2009 Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration

More information

Inductive conductivity transmitter JUMO CTI-Junior

Inductive conductivity transmitter JUMO CTI-Junior M. K. JUCHHEIM GmbH & Co Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 (0) 661 60 03-7 25 Fax: +49 (0) 661 60 03-6 81 E-Mail: mail@jumo.net

More information

Condumax CLS15 and CLS15D

Condumax CLS15 and CLS15D Technical Information Condumax CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview Siemens AG 2010 Flow Measurement Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical

More information

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Magnetic-inductive flow meter Technical Datasheet PITe / UMF2 Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up Subject to change without notice 1 Function An electrically

More information

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version Inductive Conductivity/ Concentration and Temperature Transmitter measuring monitoring analysing LCI or separate version Activation of up to four measuring ranges (up to 2000 ms/cm) Concentration measurement

More information

Technical Information Condumax CLS15D/CLS15

Technical Information Condumax CLS15D/CLS15 TI0009C/07/EN/4.4 7268306 Products Solutions Services Technical Information Condumax CLS5D/CLS5 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 0.0 cm or k = 0. cm Application

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

Signet ph/orp Electrodes

Signet ph/orp Electrodes Signet 2724-2726 ph/orp Electrodes Compatible with ALL Signet ph/orp Instruments Features Flat Protected Bulb Patented reference design for exceptional performance* Mounts in Signet standard fittings from

More information

Technical Information Indumax CLS50D/CLS50

Technical Information Indumax CLS50D/CLS50 TI00182C/07/EN/16.15 71280313 Products Solutions Services Technical Information Indumax CLS50D/CLS50 Inductive conductivity sensor for standard, Ex and high-temperature applications Digital sensor with

More information

Signet ph/orp Electrodes General Purpose

Signet ph/orp Electrodes General Purpose Signet 2724-2726 ph/orp Electrodes General Purpose Compatible with ALL Signet ph/orp instruments and SmartPro transmitters Features Patented reference design for exceptional performance and prolonged life

More information

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9 Overview MAGFLO family MAGFLO electromagnetic are designed for measuring the flow of electrically conductive mediums. The patented MAGFLO Verificator guarantees accurate measurement and simple verification.

More information

Inductive Conductivity Meter ILM

Inductive Conductivity Meter ILM 1 Product Information ILM-2 ILM-3 Inductive Conductivity Meter ILM f o o d Application / Specified Usage Authorizations Inductive measurement of the specific conductivity of liquid media in the range of

More information

FLOMID FX Electromagnetic Flowmeter

FLOMID FX Electromagnetic Flowmeter FLOMID FX Electromagnetic Flowmeter Working pressure manufacturing according to PED 97/23/CE (Lloyd s Register Certificate Nº 031) Introduction Modular design in two versions: Compact, sensor and electronics

More information

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016 J Series induq VMM J Series induq VMI J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS J DB_Magnetic_Inductive_Flow_Sensors 5/216 67 Magnetic inductive flow sensors Principle of operation The smart flow

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview Mode of operation The flow measuring principle is based on Faraday s law of electromagnetic induction according to which the sensor converts the flow into an electrical voltage proportional to

More information

Indumax CLS54D. Technical Information

Indumax CLS54D. Technical Information Technical Information Indumax CLS54D Inductive conductivity sensor with hygienic design for applications in the food, beverage and pharmaceutical industries and in biotechnology Application The CLS54D

More information

prosonic T FMU230, FMU231

prosonic T FMU230, FMU231 Technical Information prosonic T FMU230, FMU231 Ultrasonic Level Measurement Compact transmitters for non-contact level measurement of fluids and coarse bulk materials Application The compact transmitters

More information

OEM radar transmitter, for aggressive media level measurement

OEM radar transmitter, for aggressive media level measurement OEM radar transmitter, for aggressive media level measurement C ompact for level measurement up to 20 m 4... 20 ma/hart - 2 wires Adjustable with P C ATEX approvals Type 8136 can be combined with... Type

More information

Condumax W CLS15 and CLS15D

Condumax W CLS15 and CLS15D Technical Information Condumax W CLS15 and CLS15D Conductivity sensors, analog or digital with Memosens technology, Cell constant k = 0.01 cm -1 or k = 0.1 cm -1 Application Measurement in pure and ultrapure

More information

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions... Flow meter Content F2-UN Description... 3 Technical data... 4 Dimension drawings... Operation... 8 Mounting instructions... 9 Order code... 10 F1-FP Description... 11 Technical Data... 12 Dimension drawings...

More information

Technical Information Condumax CLS21D/CLS21

Technical Information Condumax CLS21D/CLS21 TI00085C/07/EN/14.14 71268310 Products Solutions Services Technical Information Condumax CLS21D/CLS21 Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1.0 cm 1 Application

More information

Target disk flowmeter for liquids and gases

Target disk flowmeter for liquids and gases Target disk flowmeter for liquids and gases Metallic, simple and robust construction Available for all flow directions Suitable for extreme pressure and temperature conditions Low pressure drop Straight

More information

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA Mobrey Ultrasonic Product Data Sheet February 215 IP245, Rev EA MSP422, MSP4RH, and MSP9GH Level Transmitters Non-contacting measurement with no moving parts Integral LCD and push-buttons as standard for

More information

Model Sono-Trak Transit Time

Model Sono-Trak Transit Time Model Sono-Trak Transit Time Ultrasonic Flow Meter Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive, bi-directional measurement with advanced ultrasonic

More information

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution P R o D u c T I n F o R m at I o n TDR Level Sensor The clean solution Level sensors The clean solution Product description The is a hygienic level sensor for liquids using TDR technology a process for

More information

Technical Information Memosens CLS82D

Technical Information Memosens CLS82D TI01188C/07/EN/03.16 71318348 Products Solutions Services Technical Information Memosens CLS82D Hygienic conductivity sensors, digital with Memosens technology, cell constant k = 0.57 cm -1 Application

More information

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box Applications Food and beverage industry Pharmaceutical industry Biotechnology industry Cosmetic industry Special Features Meets

More information

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER

MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER MIK COMPACT MAGNETO-INDUCTIVE FLOWMETER Flow Pressure Level Temperature Measurement Monitoring Control Flow Ranges from 0.18-7.8 GPH through 9-180 GPM For Use with a Wide Variety of Conductive Liquids,

More information

Echotel Model 910 Ultrasonic Level Switch

Echotel Model 910 Ultrasonic Level Switch Echotel Model 910 Ultrasonic Level Switch D E S C R I P T I O N Echotel Model 910 Level Switches utilize ultrasonic contact technology for measuring level in clean liquid applications. The dual conduit

More information

Princo MagneLevel Model LML

Princo MagneLevel Model LML Instrumentation designed with the user in mind Instruction Manual Princo MagneLevel Model LML Two-Wire Magnetic Coupled Level Transmitter 11 Nov 05 PRINCO INSTRUMENTS INC., 1020 INDUSTRIAL BLVD., SOUTHAMPTON,

More information

LST400 Ultrasonic level / open channel flow transmitter

LST400 Ultrasonic level / open channel flow transmitter Data sheet DS/LST400 EN Rev.C LST400 Ultrasonic level / open channel flow transmitter Measurement made easy Reduced installation cost Easy access terminations Integrated echo display makes for easy troubleshooting

More information

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI Function All are based on Faraday s law of induction: U M = B v d k U M = Measured voltage induced in the medium perpendicular to the magnetic field and the flow direction. The voltage is tapped at two

More information

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids

NUS-4. Ultrasonic Level Transmitter. for Liquids and Solids Ultrasonic Level Transmitter for Liquids and Solids measuring monitoring analyzing 4 Measuring Ranges: Liquids: Up to 25 meters (80 feet) Solids: Up to 10 meters (32 feet) Accuracy: ± 0.2 % of Reading

More information

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive flow Meter fmi 1 Product information fmi-c, fmi-r f o o d P H A R M A Magnetic-Inductive flow Meter fmi Application/Specified usage Magnetic-inductive flowmeter for the measurement of flow rate and volume in food and

More information

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display Electromagnetic Wafer Flowmeters with S300 display for corrosive chemicals/acids & slurries (sizes: 2.5mm to 100mm) 0BFEATURES: For aggressive chemicals, slurries, oxides, grouts & dosing applications

More information

KFS. Flap-type flow meter. Design and range of application

KFS. Flap-type flow meter. Design and range of application Design and range of application The measuring device operates largely independent of viscosity and is suitable for indicating the flow rate of water, acids, alkaline solutions and gases. Every device is

More information

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description. Page 1/17 JUMO CTI-500 Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts Type 202755 Brief description The instrument is used for the measurement/control of conductivity

More information

mass flowmeter for compressed air

mass flowmeter for compressed air mass flowmeter for compressed air VARIOMASS MF High End electronic for air measurement & analyse - 1 - The VARIOMASS flow meter for compressed air is a comfortable system for air mass flow measurement,

More information

Plug & Play. No Calibration Required

Plug & Play. No Calibration Required No Calibration Required Plug & Play No K-actor Programming Read the User's Manual Carefully before Starting to Use the Unit. All TK Series low Meters are actory Calibrated. Manufacturer reserves the right

More information

Electromagnetic flowmeter in all metal design Model MIM

Electromagnetic flowmeter in all metal design Model MIM Electromagnetic Flowmeter all metal design measuring monitoring analysing MIM O O For measuring and monitoring of conductive liquids OAccuracy: O < ± (0.8% of reading + 0.5% of full scale) O O Flow and

More information

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16 Technical Information TI 7C//ae Conductivity Measuring Cells for High-Temperature Applications Two-electrode measuring sensors with fixed cable or connector version with integrated temperature sensor Cell

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic OC Measuring and Controlling Unit Multronic OC One channel measuring and controlling unit for ph / conductivity / Chlorine measuring Automatic temperature compensation Measuring and control behaviour simultaneously

More information

Metal tube variable area flowmeters for gases, liquids and steam

Metal tube variable area flowmeters for gases, liquids and steam Metal tube variable area flowmeters for gases, liquids and steam Metallic with a robust construction, optional in plastic Indication by means of magnetic coupling Linear scales, calibrated in l/h, m3/h,

More information

High-quality pressure transmitter For general industrial applications Model S-10

High-quality pressure transmitter For general industrial applications Model S-10 Electronic pressure measurement High-quality pressure transmitter For general industrial applications Model S-10 WIKA data sheet PE 81.01 for further approvals see page 4 Applications Machine building

More information

Conductivity / Temperature Transmitter LMIT 09

Conductivity / Temperature Transmitter LMIT 09 Conductivity / Temperature Transmitter ONE unit for CIP applications, concentration monitoring and make-up Measurement value logging covering five decades of measurement ranges from 0-200 µs/cm to 0-2

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/4 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/4" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Flow rate can also be regulated by a range of electrical inputs (sensors,

More information

Pressure transmitter for general industrial applications Model A-10

Pressure transmitter for general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter for general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Machine tools Measurement and control technology

More information

Pressure transmitter For general industrial applications Model A-10

Pressure transmitter For general industrial applications Model A-10 Electronic pressure measurement Pressure transmitter For general industrial applications Model A-10 WIKA data sheet PE 81.60 Applications Machine building Ship building Measurement and control technology

More information

Signet 9950 Dual Channel Transmitter

Signet 9950 Dual Channel Transmitter Signet 9950 Dual Channel Transmitter Member of the SmartPro Family of Instruments Features One instrument for multiple sensor types Multiple language support for (Gen 2a) or later in Simplified Chinese,

More information

Electromagnetic flowmeters and switches DWM 1000/2000

Electromagnetic flowmeters and switches DWM 1000/2000 KROHNE 10/2000 D 20 DW10 02 E GR Electromagnetic flowmeters and switches DWM 1000/2000 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass

More information

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE: Unit 1 / 14 Biscayne Way Jandakot WA 6104 P.O. Box 3232, Success WA 6964 Tel: (08) 9414 7666 Fax: (08) 9414 7677 Email: dg@dginstruments.com.au Website: www.dginstruments.com.au A.B.N: 59 113 005 959 DATE:

More information

Condumax CLS21 and CLS21D

Condumax CLS21 and CLS21D Technical Information Condumax CLS21 and CLS21D Conductivity sensors, analog or digital with Memosens technology Cell constant k = 1 cm -1 Application Measurements in media of medium and high conductivities:

More information

OPTIFLUX 5000 Technical Datasheet

OPTIFLUX 5000 Technical Datasheet OPTIFLUX 5000 Technical Datasheet Electromagnetic flowmeter in flanged version Exceptional long-term stability and accuracy For highly aggressive and abrasive fluids Fully vacuum-resistant with high-tech

More information

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8" to 1/2" NPT. Proportional Valves. Features.

Posiflow Proportional Solenoid Valves % ^ ) 2/2. Brass or Stainless Steel Bodies 1/8 to 1/2 NPT. Proportional Valves. Features. 4 Posiflow Solenoid Brass or Stainless Steel Bodies 1/8" to 1/2" NPT 2/2 Features Flow rates adjustable between 0% and 100% of rating Control achieved by applying straight voltage between 0 and 24 VDC

More information

Ultrasonic level indicator type INOWAFE

Ultrasonic level indicator type INOWAFE General description KFG s two decades of experience with ultrasonic level metering is an asset we gladly share with our customers. A specialised team of experts is working day by day to convert this experience

More information

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits RHE12 Hazardous Area Coriolis Mass Flow Transmitter Features Field mounting Compact, pressure safe housing ATEX and CSA approvals for installation in hazardous areas 24 VDC power supply Configurable analog

More information

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES.

Temperature Sensor. Temperature Transmitter MPU-LCD with Display Product Information TSM and TSB FOOD SENSORS FOR FOOD AND LIFE SCIENCES. SENSORS FOR FOOD AND LIFE SCIENCES. Product Information TSM and TSB FOOD Temperature Sensor Application/Specified usage Temperature Measurement in vessels and pipes Authorizations Application examples

More information

RCM DIRECT READING FLOWMETER

RCM DIRECT READING FLOWMETER RCM DIRECT READING FLOWMETER Flow Pressure Level Temperature measurement monitoring control Special Features Compact Design Easy to Install For Horizontal or Vertical Pipes Rugged Construction Accuracy:

More information

TIDALFLUX 2300 F Technical Datasheet

TIDALFLUX 2300 F Technical Datasheet Technical Datasheet Electromagnetic flow sensor for partially filled pipes Measurement in partially filled pipes up to DN1600 / 64" Patented, non-contact level measurement Measurement possible down to

More information

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B

USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER. Rev USER MANUAL DEI MODEL USFT-B Rev012008 USER MANUAL DEI MODEL USFT-B USER MANUAL MODEL USFT-B ULTRASONIC FLOW TRANSMITTER The Model USFT-B is an ultrasonic transit time flow meter designed to accurately and reliably report the flow

More information

Measuring and Controlling Unit Multronic

Measuring and Controlling Unit Multronic Measuring and Controlling Unit Multronic Modular system Up to 3 measurement variables with control functions in one housing Free combination of the measurement variables ph / Redox / temperature / conductivity

More information

2/2 way Proportional Valve (motordriven)

2/2 way Proportional Valve (motordriven) 2/2 way Proportional (motordriven) Actuator isolated from fl ow path Excellent range and fast response times Low power consumption Orifi ce sizes 8 to 25 mm Versions: Standard, positioner, process controller

More information

Non-Submersible Industrial Pressure Transducer

Non-Submersible Industrial Pressure Transducer Non-Submersible Industrial Pressure Transducer KPSI Transducers Series 27, 28, 30 FEATURES Custom Pressure Ranges up to 2000 (13,790 kpa) Accuracy to ±0.10% FS Analog Outputs of 4-20 ma or VDC Welded 316

More information