1 The NZ Handbook 2011 Edition

2 Safety Warning Cables are insulated and sheathed with stable materials which may contain certain toxic substances including lead. Insulation and sheathing materials should not be chewed or ingested. When XLPE coloured cores are exposed to sunlight or outdoors the UV rays will break down the XLPE. Therefore they should be made safe from the effects of the UV by adding some form of UV protection. Installation Cables must be installed in accordance with the requirements of the latest issue of AS/NZS 3000 or the appropriate ruling standard in the country of installation. Cables must also be connected by a licensed electrician, as ruled in the state or country of installation. Olex New Zealand Limited has taken every precaution to ensure that the information contained in the booklet is in line with the requirements of the appropriate New Zealand Standards and correct electrical practice. However, we accept no liability of any kind with respect to the information presented here. Note Current carrying capacity tables stated in this handbook are based on AS/NZS , Electrical Installations Selection of Cables. Part 1.2: Cables for alternating voltages up to and including 0.6/1 kv Typical New Zealand Installation conditions. All information is subject to change without notice.

3 Supplier Declaration of Conformity (SDoC) In accordance with ISO/IEC :2004 SDoC identification Number Issuer details Name 2 (of New Zealand manufacturer or importer) Olex New Zealand Limited New Zealand Company Number (if applicable) AK/ Contact Address Paraite Road, Bell Block New Plymouth Telephone Fax address dgriffiths@olex.co.nz Medium Risk Article Details 3 (Product name, type, rating, brand, model, batch numbers, and serial numbers, as applicable) Conduit Wires, Cantol, Cempex, Neutral-Screen, Armoured Mains, Vintols & L.V URD The medium risk article listed above, fully complies with the standard(s), as listed:- Standard number & issue year:-as/nzs : 2005, AS/NZS 4026 : 2008 Section 4&5, AS/NZS 4961 : 2003 Section 2. Standard Title:-Electric cables Polymeric insulated Part 1: For working voltages up to and including 0.6/1 (1.2) kv. -Electric cables For underground residential distribution systems. -Electric cables Polymeric insulated-for distribution and service applications. Edition / Amendment status:- Or complies with the Conformity Cooperation Agreement - No Names and addresses of any testing organisation or body Name(s) Olex New Zealand Test Safe Australia Address(es) Paraite Road, Bell Block, New Plymouth 919 Londonderry Road, Londonderry, NSW 2753 Australia Reference to relevant test reports/certification, and issue date of the reports/certification, that show how compliance is achieved:- Report/Certification N (s) Issue date(s) Olex NZ Quality doc # QTR Test Report for L. 06/03/2009, Issue 1.0 V. Cable to AS/NZS Olex NZ Quality doc # QTR Test Report for L. 28/04/2010, Issue 1.0 V. Cable to AS/NZS 4026 Reference to any management systems involved:- Additional 4 information Declaration I hereby declare that the above specified fittings or electrical appliances comply with the requirements of Regulation 83 of the Electricity (Safety) Regulations 2010 Issuer Identification: (as affixed to the article) OLEX (NZ) CANTOL Signed for and on behalf of: Olex New Zealand Name 5 & position, as authorized by the issuer David Griffiths, Technical Manager Signature Date 12/08/ Every declaration of conformity should be uniquely identified. 2 The responsible issuer must be unequivocally specified. 3 The Article must be unequivocally described so that the declaration of conformity may be related to the article in question. For mass-produced products, it is not necessary to give individual serial numbers. Where variants of an article are to be covered, these must be detailed. 4 Text should appear here only if any limitation on the validity of the declaration of conformity and/or any additional information are given. 5 Full name and function of the signing person(s) authorised by the issuer's management to sign on its behalf should be given. The number of signatures, or equivalent, included will be the minimum determined by the legal form of the issuer s organization.

4 Supplier Declaration of Conformity (SDoC) In accordance with ISO/IEC :2004 SDoC identification Number Issuer details Name 2 (of New Zealand manufacturer or importer) Olex New Zealand Limited New Zealand Company Number (if applicable) AK/ Contact Address Paraite Road, Bell Block New Plymouth Telephone Fax address dgriffiths@olex.co.nz Medium Risk Article Details 3 (Product name, type, rating, brand, model, batch numbers, and serial numbers, as applicable) TPS & REMOLEX The medium risk article listed above, fully complies with the standard(s), as listed:- Standard number & issue year:-as/nzs : 2006 Standard Title:-Electric cables Polymeric insulated Part 2: For working voltages up to and including 450/750V. Edition / Amendment status:- Or complies with the Conformity Cooperation Agreement - No Names and addresses of any testing organisation or body Name(s) Olex New Zealand Test Safe Australia Address(es) Paraite Road, Bell Block, New Plymouth 919 Londonderry Road, Londonderry, NSW 2753 Australia Reference to relevant test reports/certification, and issue date of the reports/certification, that show how compliance is achieved:- Report/Certification N (s) Issue date(s) Olex NZ Quality doc # QTR Test Report for L. 11/03/2009, Issue 2.0 V. Cable to AS/NZS Reference to any management systems involved:- Additional 4 information Declaration I hereby declare that the above specified fittings or electrical appliances comply with the requirements of Regulation 83 of the Electricity (Safety) Regulations 2010 Signed for and on behalf of: Olex New Zealand Name 5 & position, as authorized by the issuer David Griffiths, Technical Manager Issuer Identification: Signature Date OLEX (NZ) (as affixed to the article) Cu Remolex 20/05/ Every declaration of conformity should be uniquely identified. 2 The responsible issuer must be unequivocally specified. 3 The Article must be unequivocally described so that the declaration of conformity may be related to the article in question. For mass-produced products, it is not necessary to give individual serial numbers. Where variants of an article are to be covered, these must be detailed. 4 Text should appear here only if any limitation on the validity of the declaration of conformity and/or any additional information are given. 5 Full name and function of the signing person(s) authorised by the issuer's management to sign on its behalf should be given. The number of signatures, or equivalent, included will be the minimum determined by the legal form of the issuer s organization.

5 Contents Low Voltage Alsecure Envirolex Cables... 6 Conduit Wires... 8 Cu Strand Soft Drawn TPS Cables Alsecure Envirolex TPS Cables Remolex Cables Cempex Cables Cu Distribution Cables Al Neutral-Screened Cables..18 PVC Neutral-Screened Cables XLPE Neutral-Screened Cables Cu Cantols Cu Vintols Al Cantols Al Vintols Single Core Aluminium Cables Al URD Cables PVC Armoured Mains Cables XLPE Armoured Mains Cables Control Cables...30 Armoured Control Cables Irrigation Cable Single Core Industrial Flexible Power Cable Selection Criteria Powerlex TM PVC Appliance Wires Powerlex TM PVC Flexible Cords PVC Flexible Trurip Versolex HD Single Core Versolex Multi Cords & Cables Versolex Braided Cords & Cables Titanex Multicore (H07RN-F) Buflex X Prem Reeling Cable Varolex Variable Speed Drive Cables PVC Flexible Control PVC-EMC Flexible Control Silicone Single Core Silicone Multicore Instrolex Instrumentation Cable PVC Flat Crane Cable Notes Page 3

6 Contents Data & Counication Security Cable Audiolex Figure 8 Speaker Trurip Coaxial Cable Composite Coaxial & Control Core LAN Optical Fibre Telephone Internal Telephone External Garden Lighting Fire Alarm Cable Data Cables Fire Rated Alsecure Premium Ceramifiable Single Core Alsecure Premium Ceramifiable Multi Core Alsecure Premium FRP Ceramifiable Alsecure Premium Flex Ceramifiable Aerial AAC Aerial Conductors AAAC Aerial Conductors ACSR Aerial Conductors Al Aerial Bundled Cables (ABC) Al Binder Wire Cu Aerial - Hard Drawn Cu Aerial - Trurip Cu Aerial Neutral Screens Cu Binder Wire...86 Notes Glands & Accessories A2 Industrial Glands A2F Dual Certified EEx d & EEx e Glands VSD Glands...89 A4 Industrial Glands CW Industrial Glands E1FW Dual Certified EEx d & EEx e Glands CX/Z Industrial Glands PX2K Flameproof EEx d Glands Gland Accessories PVC Shrouds Notes...94 Page 4

7 Contents General Technical Information Installation Information Minimum Spacings in Air to Avoid Derating Single Core Cables in Parallel Bending Radii Duct Sizes Pulling Tension Copper Conductor Dimensions Aluminium Conductor Dimensions Cable Selection Four Main Factors Procedures Current Ratings Simple Cable Selection Chart Low Voltage (0.6/1 kv) Rating Factors Current Ratings Single Conductor PVC (Single Phase) Single Conductor XLPE (Single Phase) Two Conductor PVC (Single Phase) Two Conductor XLPE (Single Phase) Single Conductor PVC (Three Phase) Single Conductor XLPE (Three Phase) Single Conductor Ceramifiable (Three Phase) Three & Four Conductor PVC (Three Phase) Three & Four Conductor XLPE (Three Phase) PVC Flexible Cords Versolex Single Core Flexible Cables (Single Phase) Versolex Single Core Flexible Cables (Three Phase) Versolex Two Core Flexible Cables (Single Phase) Versolex Three & Four Core Flexible Cables (Three Phase) AAC Aerial Conductors AAAC Aerial Conductors ACSR Aerial Conductors Al Aerial Bundled Cables (ABC) Cu Aerial Hard Drawn General Data Useful 3 Phase Formulae Wire & Cable Size Comparison Motor Current Table (Amperes approx) Abbreviations Copper Earthing Conductors Page 5

8 Alsecure Envirolex Cables Alsecure Envirolex cables are an extensive range of enhanced performance cables for the construction industry engineered to dramatically reduce environmental impact, particularly under fire conditions, while retaining the excellent mechanical and electrical properties designed into Olex cables. Olex uses a variety of inorganically filled polyolefin based materials to engineer the cables in the Alsecure Envirolex range to meet a wide variety of end uses and performance requirements. Advantages of Alsecure Envirolex cables Cable types from building wires to SWA, to multicore control 90ºC rated superior thermal performance Improved performance under fire conditions: - Flame retardant/self-extinguishing - Reduced acid, gas and smoke generation - Non-corrosive in fire situations - Reduced toxicity of fumes during fire Halogen free (i.e. no chlorine, bromine etc) Lead free No special termination or installation requirements Made in accordance with Australian and New Zealand Standards Alsecure Envirolex cables have been tested according to and comply with the requirements of the single flame tests specified in AS1660. Alsecure Envirolex products include readily strippable cables for general construction purposes as well as the tougher products coonly found in cables with higher fire performance capability. Information on the Alsecure Envirolex range of 2 core plus earth and 3 core flat cables can be found on page 14 of this handbook. Alsecure Envirolex materials can also be used as alternatives to all other low voltage power and control cables. Cables are available on request, subject to minimum production run. Page 6

9 Page 7

10 Conduit Wires Cu conductor, PVC insulation. 0.6/1 kv. Made to AS/NZS Area ² Colour Nom Dia Approx Mass V90HT Insulation BAAP01AD001AABK BK V90 Insulation BAAP02C1001AABK BK BAAP02C1001AABE BU BAAP02C1001AAGN GN BAAP02C1001AARD RD BAAP02C1001AAWT WH BAAP05C1001AABK BK BAAP05C1001AABE BU BAAP05C1001AAHN GNYE BAAP05C1001AARD RD BAAP05C1001AAWT WH BAAP07C1001AABK BK BAAP07C1001AABE BU BAAP07C1001AAHN GNYE BAAP07C1001AARD RD BAAP07C1001AAWT WH BAAP09A1001AABK BK BAAP09C1001AABE BU BAAP09C1001AAHN GNYE BAAP09C1001AARD RD BAAP09C1001AAWT WH V75 Insulation BAAP11A1001AABK BK BAAP11A1001AABE BU BAAP11A1001AAHN GNYE BAAP11A1001AARD RD BAAP11A1001AAWT WH Note: Conductors 1.5 ² and above are circular stranded. continued Page 8

11 Conduit Wires Cu conductor, PVC insulation. 0.6/1 kv. Made to AS/NZS Area ² Colour Nom Dia Approx Mass V75 Insulation BAAP13A1001AABK BK BAAP13A1001AABE BU BAAP13A1001AAHN GNYE BAAP13A1001AARD RD BAAP13A1001AAWT WH BAAP15AA001AABK BK BAAP15AA001AABE BU BAAP15AA001AAHN GNYE BAAP15AA001AARD RD BAAP15AA001AAWT WH BAAP16AA001AACX BK BAAP16AA001AABF BU BAAP16AA001AAHT GNYE BAAP16AA001AAJB RD BAAP16AA001AAWV WH BAAP18AA001AACX BK BAAP18AA001AABF BU BAAP18AA001AAHT GNYE BAAP18AA001AAJB RD BAAP18AA001AAWV WH BAAP19AA001AAHT GNYE BAAP19AA001AAJB RD BAAP20AA001AAHT GNYE BAAP21AA001AAHT GNYE BAAP23AA001AAHT GNYE Note: Conductors 1.5 ² and above are circular stranded. Page 9

12 Cu Strand Soft Drawn Cu conductor. Made to AS/NZS Area ² Nom Dia Approx Mass ACUP15AA001AAAA ACUP17AA001AAAA ACUP18AA001AAAA ACUP19AA001AAAA ACUP20AA001AAAA ACUP21AA001AAAA ACUP23AA001AAAA Page 10

13 TPS Cables Cu conductor, PVC insulation, PVC sheath. 450/750 V. Made to AS/NZS Area ² Colour Nom Dia Gland Approx Size Mass A2 or A2F Single Core AABP02A1001WVBK * BK WH S/ AABP02A1001WVRD * RD WH S/ AABQ05A1001WVBK BK WH S/ AABQ05A1001WVRD RD WH S/ AABP07A1001WVBK BK WH S/ AABP07A1001WVRD RD WH S/ AABP09A1001WVBK BK WH S/ AABP09A1001WVRD RD WH S/ AABP11A1001WVBK BK WH S/ AABP11A1001WVRD RD WH S/ AABP13A1001WVBK BK WH S/ AABP13A1001WVRD RD, WH S/ AABP15A1001WVBK BK WH S 0.22 AABP15A1001WVRD RD WH S 0.22 Note: Conductors 1.5 ² and above are circular stranded. * Solid conductor Page 11

14 TPS Cables Cu conductors, PVC insulation, PVC sheath. 450/750 V. Made to AS/NZS Cores x Area ² Sheath Nom Dim Approx Mass Two Core CACP02A1002JBHF x 1.0 * RD 4.0 x CACP02A1002WVHF x 1.0 * WH 4.0 x CACP02AA002ASWV x 1.0 * WH (R+R) 4.0 x CACQ05A1002JBHF x 1.5 RD 4.7 x CACQ05A1002WVHF x 1.5 WH 4.7 x CACP05AA002ASWV x 1.5 WH (R+R) 4.7 x CACP07A1002JBHF x 2.5 RD 5.3 x CACP07A1002WVHF x 2.5 WH 5.3 x CACP07A1002WVAB x 2.5 WH (R+W) 5.3 x CACP09A1002WVHF x 4 WH 6.3 x CACP11A1002WVHF x 6 WH 7.0 x CACP15AA002CXHF x 16 BK 10.0 x Two Core Plus Pilot QCPP15AA002CXHF x P BK 9.9 x QCQP16AA002CXHF x P BK 11.8 x Two Core Plus Earth CNZP02A1002WVHF x E* WH 4.0 x CNZQ05A1002WVHF x E WH 4.7 x CNZP07A1002WVHF x E WH 5.3 x CNZP09A1002WVHF x E WH 6.4 x CNZP11AA002WVHF x E WH 6.9 x CNZP13EC002WVHF x E WH 8.5 x CNZP15AA002CXHF x E BK 9.9 x Note: Conductors 1.5 ² and above are circular stranded. * Solid conductor continued Page 12

15 TPS Cables Cu conductors, PVC insulation, PVC sheath. 450/750 V. Made to AS/NZS Cores x Area ² Sheath Nom Dim Approx Mass Three Core EACP02A1003YXRJ x 1.0 * YE 4.0 x EACQ05A1003YXRJ x 1.5 YE 4.6 x EACP07A1003WVHF x 2.5 WH 5.3 x Three Core Plus Earth ENZP02A1003WVRJ x E* WH 4.0 x ENZQ05A1003WVRJ x E WH 4.7 x ENZP07A1003WVRJ x E WH 5.3 x ENZP09A1004WVPF x E WH 6.5 x ENZP11AA003WVRJ x E WH 7.2 x Four Core GACP07A1004WVEM x 2.5 WH 5.3 x GACP09A1004WVEM x 4 WH 6.5 x Note: Conductors 1.5 ² and above are circular stranded. * Solid conductor Page 13

16 Alsecure Envirolex TPS Cables Cu conductors, X-HF-90 insulation, Green HFS-90-TP sheath. 450/750V. Made to AS/NZS Cores x Area ² Nom Dim Approx Mass Two Core Plus Earth CTCP05JA x E 4.6 x CTCP07JA x E 5.3 x CTCP09JA x E 6.2 x CTCP11JA x E 6.8 x Three Core EECP05J1003GGRJ x x Note: Alsecure Envirolex cables are lead and halogen free and are suitable for green building installations. Page 14

17 Remolex Cables Cu conductors, PVC insulation, Laid up, Black PVC sheath. 450/750 V. Made to AS/NZS Circular multicore with integral earth. Cores x Area ² Nom Dia Gland Size A2 or A2F Approx Mass Two Core Plus Earth CNHQ05AA002CXHF x E S 0.12 CNHP07AA002CXHF x E S 0.17 CNHP09AA002CXHF x E CNHP11AA002CXHF x E CNHP15AA002CXHF x E Three Core Plus Earth ENHQ05AA003CXRJ x E S 0.15 ENHP07AA003CXRJ x E S 0.21 ENHP09AA003CXRJ x E ENHP11AA003CXRJ x E ENHP13AA003CXRJ x E ENHP15AA003CXRJ x E Four Core Plus Earth GNHQ05AA004CXEM x E GNHP07AA004CXEM x E GNHP09AA004CXEN x E Core Colours No. Cores Colour 3 RD, BK, GNYE 4 RD, WH, BU, GNYE 5 RD, WH, BU, BK, GNYE Note: Conductors 1.5 ² and above are circular stranded. Page 15

18 Cempex Cables Cu conductors, XLPE insulation, Laid up, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Circular multicore with integral earth. Cores x Area ² Nom Dia Gland Size A2 or A2F Approx Mass Three Core Plus Earth FTHC17AA003CXRJ x 25 ^ + 6 E FTHC38AA003CXRJ x 35 ^ + 10 E FTHC19AA003CXRJ x 50 ^ + 16 ^ E x 70 ^ + 25 ^ E Four Core Plus Earth HTHP11AA004CXEM x E HTHP13AA004CXEM x E HTHP15AA004CXEM x 16 ^ + 6 E HTHC17AA004CXEM x 25 ^ + 6 E HTHC18AA004CXEM x 35 ^ + 10 E HTHC19AA004CXEM x 50 ^ + 16 ^ E HTHC20AA004CXEM x 70 ^ + 25 ^ E S 3.20 HTHC21AA004CXEM x 95 ^ + 25 ^ E Core Colours No. Cores Colour 4 RD, WH, BU, GNYE 5 RD, WH, BU, BK, GNYE Note: ^ Conductors 16 ² and above are compact circular stranded. Conductors 10 ² and below are circular stranded. Page 16

19 Cu Distribution Cables Cu conductors, XLPE insulation, Black PVC sheath. Vector specification. Cores x Area ² Nom Dia Approx Mass Conductor Size 16 ² DEVP15VT002CXHF x HEVP15VT004CXEM x Conductor Size 25 ² DEVC16VT002CXHF x HEVC16VT004CXEM x Conductor Size 35 ² DEVC38VT002CXHF x Core Colours No. Cores Colour 2 RD, BK 4 RD, WH, BU, BK Note: Conductors are circular stranded. Page 17

20 Al Neutral-Screened Cables Al conductors, XLPE insulation, Laid up, Cu neutral screen, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Approx Mass Single Core BDGH20PX001CXRD x 70 ^ BDGH21PX001CXRD x 95 ^ BDGH43PX001CXRD x 120 ^ BDGH25PX001CXRD x 185 ^ Single Core Plus Pilot QDQH20PX001CXRD x 70 ^ + 4 P 29.2 x Three Core FEGH38PX003CXRJ x FEGH39PX003CXRJ x FEGG20PX003CXRJ x FEGG21PX003CXRJ x Three Core Plus Pilot QDZG23PX003CXRJ x P QDZG25PX003CXRJ x P QDZG27PX003CXRJ x P Core Colours No. Cores Colour 3 RD, WH, BU 3 (Plus Pilot) RD, WH, BU, OG 4 RD, WH, BU, BK Note: Single Core - ^ Conductors are compact circular stranded. Three Core - Conductors are shaped stranded. 3.2 sheath, unless indicated by * which is 1.8 sheath Page 18

21 PVC Neutral-Screened Cables Cu conductors, PVC insulation, Cu wire neutral screen, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dim Gland Size CX/Z A2 Approx Mass Single Core BAGP07AA001CXRD x 2.5 * S/16 20S 0.13 BAGP09PX001CXRD x S BAGP11PX001CXRD x S BAGP13PX001CXRD x S BAGP15PX001CXRD x BAGP16PX001CXRD x BAGP18PX001CXRD x BAGP19PX001CXRD x Single Core Plus Pilot QDBP15PX001CXRD x P 15.5 x QDBP16PX001CXRD x P 17.6 x Two Core DAEP07AA002CXAB x 2.5 * 8.6 x DAEP07PX002CXAB x x DAEP09AA002CXAB x 4 * 9.6 x DAEP11AA002CXAB x 6 * 10.1 x DAEP11PX002CXAB x x DAEP13PX002CXAB x x DAEP15PX002CXAB x x DAEP17PX002CXAB x x DAEP18PX002CXAB x x Note: Conductors are circular stranded. 3.2 sheath, unless indicated by * which is 1.8 sheath continued Page 19

22 PVC Neutral-Screened Cables Cu conductors, PVC insulation, Cu wire neutral screen, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Gland Size CX/Z A2 Approx Mass Two Core Plus Pilot QDIP15PX002CXAB x P Three Core FAGP07AA003CXRJ x 2.5 * S FAGP09AA003CXRJ x 4 * S FAGP11AA003CXRJ x 6 * FAGP13PX003CXRJ x Four Core HAGP07AA004CXEM x 2.5 * S HAGP09AA004CXEM x 4 * HAGP11AA004CXEM x 6 * HAGP13PX004CXEM x Core Colours No. Cores Colour 1 RD 1 (Plus Pilot) RD, OG 2 RD, WH 2 (Plus Pilot) RD, WH, OG 3 RD, WH, BU 4 RD, WH, BU, BK Note: Conductors are circular stranded. 3.2 sheath, unless indicated by * which is 1.8 sheath Page 20

23 XLPE Neutral-Screened Cables Cu conductors, XLPE insulation, Laid up, Cu wire neutral screen, 3.2 Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Gland Size CX/Z A2 Approx Mass Three Core FEGP15PX003CXRJ x 16 * FEGC16PX003CXRJ x 25 ^ FEGV18PX003CXRJ x FEGV19PX003CXRJ x FEGV20PX003CXRJ x S 3.12 FEGV21PX003CXRJ x S 4.18 Three Core Plus Pilot QDXP15AA003CXRJ x P Four Core HEGP15PX004CXEM x 16 * HEGC17PX004CXEM x 25 ^ HEGV35PX004CXEM x HEGV36PX004CXEM x S 2.78 HEGV20PX004CXEM x S x S HEGV23PX004CXEM x S 6.55 Core Colours No. Cores Colour 3 RD, WH, BU 3 (Plus Pilot) RD, WH, BU, OG 4 RD, WH, BU, BK Note: Conductors 35 ² and above are shaped stranded. * Circular stranded ^ Compact circular stranded Page 21

24 Cu Cantols Cu conductor, XLPE insulation, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Area ² Nom Dia Gland Size A2 or A2F Approx Mass BDBP15AA001CXNA ^ S 0.21 BDBC17AA001CXNA ^ S 0.31 BDBC18AA001CXNA ^ BDBC19AA001CXNA ^ BDBC20AA001CXNA ^ BDBC21AA001CXNA ^ BDBC23AA001CXNA ^ BDBC44AA001CXNA ^ BDBC25AA001CXNA ^ BDBC26AA001CXNA ^ BDBC47AA001CXNA ^ BDBC28AA001CXNA ^ S 3.96 BDBC30AA001CXNA ^ S 4.98 BDBC32AA001CXNA ^ Note: ^ Conductors are compact circular stranded. Page 22

25 Cu Vintols Cu conductor, PVC insulation, PVC sheath. Made to AS/NZS Area ² Sheath Nom Dia Gland Approx Size Mass A2 or A2F BABP09AA001OMNA OG S/ BABP15AA001CXNA BK BABP15AA001BFNA BU BABP15AA001JBNA RD BABP15AA001WVNA WH BABP16AA001CXNA BK BABP16AA001BFNA BU BABP16AA001JBNA RD BABP16AA001WVNA WH BABP18AA001CXNA BK BABP18AA001BFNA BU BABP18AA001JBNA RD BABP18AA001WVNA WH BABP20AA001CXNA BK BABP20AA001BFNA BU BABP20AA001JBNA RD BABP20AA001WVNA WH Note: Conductors are circular stranded. Page 23

26 Al Cantols Al conductor, XLPE insulation, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Area ² Nom Dia Gland Size A2 or A2F Approx Mass Stranded Al Conductor BDBH20AA001CXNA ^ BDBH21AA001CXNA ^ BDBH43AA001CXNA ^ BDBH44AA001CXNA ^ BDBH25AA001CXNA ^ BDBH26AA001CXNA ^ BDBH27AA001CXNA ^ BDBH28AA001CXNA ^ BDBH30AA001CXNA ^ S 1.87 BDBH32AA001CXNA ^ BDBH33AA001CXNA ^ S 3.01 Note: ^ Conductors are compact circular stranded. Page 24

27 Al Vintols Al conductor, PVC insulation, PVC sheath. 0.6/1 kv. Made to AS/NZS Area ² Sheath Nom Dia Gland Approx Size Mass A2 or A2F BABA20AA001CXNA BK BABA20AA001BFNA BU BABA20AA001JBNA RD BABA20AA001WVNA WH BABA21AA001CXNA BK BABA21AA001BFNA BU BABA21AA001JBNA RD BABA21AA001WVNA WH BABA23AA001CXNA BK BABA23AA001BFNA BU BABA23AA001JBNA RD BABA23AA001WVNA WH BABA25AA001CXNA BK BABA25AA001BFNA BU BABA25AA001JBNA RD BABA25AA001WVNA WH BABH26AA001CXNA ^ BK BABH26AA001BFNA ^ BU BABH26AA001JBNA ^ RD BABH26AA001WVNA ^ WH Note: Conductors are circular stranded. ^ Compact circular stranded Page 25

28 Single Core Aluminium Cables Al conductor, PVC insulation, PVC sheath. 0.6/1 kv. Made to AS/NZS Conductor Name Area ² Sheath Nom Dia Approx Mass BABA42AA001CXNA 5998 Namu 24 BK BABA42AA001JBNA 4358 Namu 24 RD BABA42AA001PPNA 7436 Namu 24 VT BABA44AA001CXNA 4762 Kutu 49 BK BABA44AA001BFNA 2739 Kutu 49 BU BABA44AA001JBNA 3369 Kutu 49 RD BABA44AA001WVNA 5771 Kutu 49 WH BABA46AA001CXNA 1994 Beetle 106 BK BABA46AA001BFNA 4369 Beetle 106 BU BABA46AA001JBNA 3177 Beetle 106 RD BABA46AA001WVNA 4847 Beetle 106 WH BABA47AA001CXBK 5622 Weta 167 BK BK BABA47AA001CXRD 3863 Weta 167 RD BK Note: Conductors are circular stranded. Page 26

29 Al URD Cables Al conductors, XLPE insulation, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Approx Mass XDDH39AA004CXAA x 50 ^ XDDG20AA004CXAA x XDDG21AA004CXAA x XDDG23AA004CXAA x XDDG25AA004CXAA x XDDG26AA004CXAA x XDDG27AA004CXAA x Note: Conductors are shaped stranded. ^ Compact circular stranded Page 27

30 PVC Armoured Mains Cables Cu conductors, PVC insulation, Laid up, Extruded bedding, GSW armour, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Gland Size CW or E1FW Approx Mass Two Core Plus Earth DNMP07AA002CXHF x E DNMP09AA002CXHF x E Three Core FAMP07AA003CXRJ x FAMP09AA003CXRJ x FAMP11AA003CXRJ x FAMP13AA003CXRJ x FAMP15AA003CXRJ x FAMV16AA003CXRJ x Three Core Plus Earth FNMP07AA003CXRJ x E Four Core HAMP07AA004CXEM x HAMP09AA004CXEM x HAMP11AA004CXEM x Four Core Plus Earth HNMP09AA004CXEM x E Core Colours No. Cores Colour 2 RD, BK 2 (Plus Earth) RD, BK, GNYE 3 RD, WH, BU 3 (Plus Earth) RD, WH, BU, GNYE 4 RD, WH, BU, BK 4 (Plus Earth) RD, WH, BU, BK, GNYE Note: Conductors are circular stranded. Conductors 25 ² and above are shaped stranded. Page 28

31 XLPE Armoured Mains Cables Cu conductors, XLPE insulation, Laid up, Extruded bedding, GSW armour, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² Nom Dia Gland Size CW or E1FW Approx Mass Four Core HEMP15AA004CXEM x 16 * HEMC16AA004CXEM x HEMV35AA004CXEM x HEMV36AA004CXEM x HEMV20AA004CXEM x HEMV24AA004CXEM x S 8.85 HEMV25AA004CXEM x S Core Colours No. Cores Colour 4 RD, WH, BU, BK Note: Conductors 25 ² and above are shaped stranded. * Circular stranded Page 29

32 Control Cables Cu conductors, PVC insulation (numbered cores), Laid up, Black PVC sheath. 450/750 V. Made to AS/NZS Cores x Area ² Nom Dia Gland Size A2 or A2F Approx Mass Conductor Size 1.5 ² CAHQ05AA002CXWW x S 0.11 EAHQ05AA003CXWW x S 0.12 GAHQ05AA004CXWW x S 0.15 APAQ05AA007CXWW x APAQ05AA012CXWW x APAQ05AA019CXWW x APAQ05AA027CXWW x APAQ05AA037CXWW x Conductor Size 2.5 ² CAHP07AA002CXWW x S 0.14 EAHP07AA003CXWW x S 0.17 GAHP07AA004CXWW x APAP07AA007CXWW x APAP07AA012CXWW x APAP07AA019CXWW x Page 30

33 Armoured Control Cables Cu conductors, PVC insulation (numbered cores), Laid up, Extruded bedding, GSW armour, Black PVC sheath. 0.6/1 kv. Made to BS Cores x Area ² Nom Dia Gland Size CW or E1FW Approx Mass Conductor Size 1.5 ² DAMQ05NG002CXWW x S 0.32 FAMQ05NG003CXWW x S 0.33 HAMQ05NG004CXWW x S 0.38 BPCQ05NG007CXWW x BPCQ05NG012CXWW x BPCQ05NG019CXWW x BPCQ05NG027CXWW x Conductor Size 2.5 ² FAMP07NG003CXWW x S 0.41 HAMP07NG004CXWW x S 0.47 BPCP07NG007CXWW x BPCP07NG012CXWW x BPCP07NG019CXWW x BPCP07NG027CXWW x BPCP07NG037CXWW x Page 31

34 Irrigation Cable Single Core Annealed Cu wire, Polypropylene insulation. 0.6/1 kv. Area ² Sheath Nom Dia Max DC 20ºC Ohm/km Approx Mass Conductor Size 1.5 ² QADP05AA001AAJB RD QADP05AA001AACX BK QADP05AA001AAYF YE QADP05AA001AABF BU Conductor Size 2.5 ² QADP07AA001AAJB RD QADP07AA001AACX BK QADP07AA001AAYF YE QADP07AA001AAWT WH Page 32

35 Page 33

36 Flexible Power Cable Selection Criteria Flexibility Operating Temperature Water Iersion Physical Toughness Oils/fuels/ Solvents Acids/ Bases Heat Environment Environmental Exposure Electromagnetic Compatibility Lead Free Pb Does not kink Fixed -40ºC to +90ºC Submersible to 500m Durable and resistant to crush and abrasion Resistant to coon oils and solvents Resistant to coon acid and alkaline chemicals Flame retardant. Tested to IEC and AS/NZS Resistant to ozone and UV Screened range designed for applications with EMC requirements Lead Free Note: Selection criteria graphs are a guide only. For further data, please contact the Olex Technical Support on 0800 OLEX NZ. Page 34

37 Powerlex PVC Appliance Wires Flexible tinned Cu conductor, PVC insulation. 0.6/1 kv. Made to AS/NZS Area ² Colour Nom Dia Approx Mass Conductor Size 0.5 ² BAAR51D1001AABK BK BAAR51D1001AABN BN BAAR51D1001AABE BU BAAR51D1001AAHN GNYE BAAR51D1001AAGY GY BAAR51D1001AAOG OG BAAR51D1001AARD RD BAAR51D1001AAWT WH Conductor Size 0.75 ² BAAR52D1001AABK BK BAAR52D1001AABN BN BAAR52D1001AABE BU BAAR52D1001AAHN GNYE BAAR52D1001AAGY GY BAAR52D1001AAOG OG BAAR52D1001AAPK PK BAAR52D1001AARD RD BAAR52D1001AAVL VT BAAR52D1001AAWT WH Conductor Size 1.0 ² BAAR53D1001AABK BK BAAR53D1001AABN BN BAAR53D1001AABE BU BAAR53D1001AAHN GNYE BAAR53D1001AAGY GY BAAR53D1001AAOG OG BAAR53D1001AAPK PK BAAR53D1001AARD RD BAAR53D1001AAVL VT BAAR53D1001AAWT WH continued Page 35

38 Powerlex PVC Appliance Wires Flexible tinned Cu conductor, PVC insulation. 0.6/1 kv. Made to AS/NZS Area ² Colour Nom Dia Approx Mass Conductor Size 1.5 ² BAAR54D1001AABK BK BAAR54D1001AABN BN BAAR54D1001AABE BU BAAR54D1001AAHN GNYE BAAR54D1001AAGY GY BAAR54D1001AAOG OG BAAR54D1001AARD RD BAAR54D1001AAVL VT BAAR54D1001AAWT WH Conductor Size 2.5 ² BAAR55D1001AABK BK BAAR55D1001AABE BU BAAR55D1001AAHN GNYE BAAR55D1001AAGY GY BAAR55D1001AAOG OG BAAR55D1001AARD RD BAAR55D1001AAWT WH Conductor Size 4 ² BAAR56D1001AABK BK BAAR56D1001AABE BU BAAR56D1001AAHN GNYE BAAR56D1001AARD RD BAAR56D1001AAWT WH Conductor Size 6 ² BAAR57D1001AABK BK BAAR57D1001AABE BU BAAR57D1001AAHN GNYE BAAR57D1001AARD RD BAAR57D1001AAWT WH Page 36

39 Powerlex PVC Flexible Cords Flexible Cu conductors, PVC insulation, Laid up, PVC sheath. 250/440V. Made to AS/NZS Cores x Area ² Sheath Nom Dia Gland Size A2 Approx Mass Two Core CAHR01A1002BKAA x 0.5 BK S/ CAHR01A1002WTAA x 0.5 WH S/ CAHR02A9002BKAA x 0.75 BK S/ CAHR02A1002KKAA x 0.75 WH S/ CAHR03A1002BKAA x 1.0 BK S/ CAHR03A1002KKAA x 1.0 WH S/ CAHR04A1002BKAA x 1.5 BK S 0.09 CAHR04A1002WTAA x 1.5 WH S 0.09 Two Core Plus Earth EAHR01A1003BKAA x E BK S/ EAHR01A1003WTAA x E WH S/ EAHR02A1003BKAA x E BK S/ EAHR02A1003KKAA x E WH S/ EAHR03A1003BKAA x E BK S/ EAHR03A1003KKAA x E WH S/ EAHR04A1003BKAA x E BK S 0.11 EAHR04A1003KKAA x E WH S 0.11 EAHR05A1003BKAA x E BK EAHR05A1003WTAA x E WH Three Core Plus Earth GAHR02A1004BKAA x E BK S/ GAHR02A1004WTAA x E WH S/ GAHR03A1004BKDV x E BK S 0.10 GAHR03A1004WTAA x E WH S 0.10 GAHR04A1004BKDV x E BK S 0.14 GAHR04A1004WTAA x E WH S 0.14 GAHR05A1004BKDV x E BK Four Core Plus Earth GNHR03A1005BKAA x E GY GNHR05A1005BKAA x E GY Core Colours No. Cores Colour No. Cores Colour 2 BN, BU 3 (Plus Earth) BN, WH, BU, GNYE 2 (Plus Earth) BN, BU, GNYE 4 (Plus Earth) BN, WH, BU, BK, GNYE Page 37

40 PVC Flexible Trurip Figure 8 construction, Flexible Cu conductors, PVC insulation. 250/250V. Made to AS/NZS Cores x Area ² Colour Nom Dim Approx Mass Conductor Size 0.75 ² JSF.75BK x 0.75 BK 3.1 x JSF.75WT x 0.75 WH 3.1 x Page 38

41 Versolex HD Single Core Cu conductors, Flexible XLPE insulation, TPE sheath. 0.6/1 kv. Designed to AS/NZS and AS/NZS Cut to length. Area ² Sheath Nom Dia Gland Approx Size Mass A2 or A2F Single Core BDSR07AA001OMNA * OG S/ BDSR07AA001CXNA * BK S/ BDSX01AA001OMNA OG S 0.14 BDSX01AA001CXNA BK S 0.14 BDSX01AA001HTNA GNYE S 0.14 BDSX01AA001JBNA RD S 0.14 BDSX02AA001OMNA OG S 0.20 BDSX02AA001CXNA BK S 0.20 BDSX02AA001HTNA GNYE S 0.20 BDSX02AA001JBNA RD S 0.20 BDSX03AA001OMNA OG BDSX03AA001CXNA BK BDSX03AA001HTNA GNYE BDSX03AA001JBNA RD BDSX04AA001OMNA OG BDSX04AA001CXNA BK BDSX04AA001HTNA GNYE BDSX04AA001JBNA RD BDSX05AA001OMNA OG BDSX05AA001CXNA BK BDSX05AA001HTNA GNYE BDSX05AA001JBNA RD * Complies only to AS/NZS continued Page 39

42 Versolex HD Single Core Cu conductors, Flexible XLPE insulation, TPE sheath. 0.6/1 kv. Designed to AS/NZS and AS/NZS Cut to length. Area ² Sheath Nom Dia Gland Approx Size Mass A2 or A2F Single Core BDSX06AA001OMNA OG BDSX06AA001CXNA BK BDSX06AA001HTNA GNYE BDSX06AA001JBNA RD BDSX07AA001OMNA OG BDSX07AA001CXNA BK BDSX07AA001HTNA GNYE BDSX07AA001JBNA RD BDSE87AA001OMNA OG BDSE87AA001CXNA BK BDSE87AA001HTNA GNYE BDSE88AA001OMNA OG BDSE88AA001CXNA BK BDSE89AA001OMNA OG BDSE89AA001HTNA GNYE BDSE90AA001OMNA OG BDSE91AA001OMNA * OG BDSE91AA001CXNA * BK BDSE92AA001OMNA * OG S 3.91 BDSE92AA001CXNA * BK S 3.91 BDSE93AA001OMNA * OG BDSE94AA001OMNA * OG S 6.33 BDSE94AA001CXNA * BK S 6.33 * Complies only to AS/NZS Page 40

43 Versolex Multicore Cords & Cables Cu conductors, Flexible XLPE insulation, TPE sheath. 0.6/1 kv. Designed to AS/NZS 3191 (Cords), AS/NZS (Cables). Cut to length. Cores x Area ² Sheath Nom Dia Gland Size A2 or A2F Approx Mass Two Core CFGR03AA002CXJJ x 1.0 BK S 0.07 CFGR04AA002CXJJ x 1.5 BK S 0.09 CFGR05AA002CXJJ x 2.5 BK S 0.13 Two Core Plus Earth EFGR03AA003CXKA x E BK S 0.09 EFGR03AA003OMKA x E OG S 0.09 EFGR04AA003CXKA x E BK S 0.12 EFGR04AA003OMKA x E OG S 0.12 EFGR05AA003CXKA x E BK EFGR05AA003OMKA x E OG EFGR06AA003CXKA x E BK EFGR06AA003OMKA x E OG FEHR07AA003CXTD x E BK FEHR07AA003OMTD x E OG Three Core Plus Earth or Three Core Plus Three Earths GFGR03AA004CXSA x E BK S 0.11 GFGR03AA004OMSA x E OG S 0.11 GFGR04AA004CXSA x E BK S 0.14 GFGR04AA004OMSA x E OG S 0.14 GFGR05AA004CXSA x E BK GFGR05AA004OMSA x E OG GFGR06AA004CXSA x E BK GFGR06AA004OMSA x E OG FTAR07AA003CXRW x SE* BK FTAR07AA003OMPF x SE* OG Core Colours No. Cores Colour 2 BN, Lt BU 3 ( 4²) BN, Lt BU, GNYE 3 ( 6²) RD, BK, GNYE 4 ( 4²) BN, WH, Lt BU, GNYE 4 ( 6²) RD, NAT, BU, GNYE * Combined Earth Size continued Page 41

44 Versolex Multicore Cords & Cables Cu conductors, Flexible XLPE insulation, Black TPE sheath. 0.6/1 kv. Designed to AS/NZS 3191 (Cords), AS/NZS (Cables). Cut to length. Cores x Area ² Nom Dia Gland Size A2 or A2F Approx Mass Three Core Plus Earth or Three Core Plus Three Earths FTAX01AA003CXRW x SE* FTAX02AA003CXRW x SE* FTAX03AA003CXRW x SE* FTAX04AA003CXRW x SE* FTAX05AA003CXRW x SE* FTAX06AA003CXRW x SE* S 2.79 FTAX07AA003CXRW x SE* Four Core Plus Earth BWBR03AA005CXSB x E BWBR04AA005CXSB x E BWBR05AA005CXSB x E BWBR06AA005CXSB x E BWBR07AA005CXLR x E BWBX01AA005CXLR x E BWBX02AA005CXLR x E BWBX03AA005CXLR x E BWBX04AA005CXLR x E BWBX05AA005CXLR x E S 2.85 Core Colours No. Cores Colour 4 ( 4²) BN, WH, Lt BU, GNYE 4 ( 6²) RD, NAT, BU, GNYE 5 ( 4²) BN, OG, WH, Lt BU, GNYE 5 ( 6²) RD, NAT, BU, BK, GNYE * Combined Earth Size Page 42

45 Versolex Braided Cords & Cables Cu conductors, Flexible XLPE insulation, TPE bedded, Cu wire braid screen, TPE sheath. 0.6/1 kv. Designed to AS/NZS 3191 (Cords), AS/NZS (Cables). Cut to length. Cores x Area ² Sheath Nom Dia Gland Size CX/Z Approx Mass Two Core Plus Earth EATR04AA003BKKA x E BK S 0.21 EATR04AA003OGAA x E OG S 0.21 Three Core Plus Earth or Three Core Plus Three Earths GETR04AA004CXSA x E BK S 0.24 GETR04AA004OGSA x E OG S 0.24 GETR05AA004CXSA x E BK S 0.31 GETR06AA004CXSA x E BK FTTR07AA003CXPF x SE* BK FTTX01AA003CXPF x SE* BK FTTX02AA003CXPF x SE* BK FTTX03AA003CXPF x SE* BK FTTX04AA003CXPF x SE* BK FTTX05AA003CXPF x SE* BK FTTX06AA003CXPF x SE* BK S 3.25 FTTX07AA003CXPF x SE* BK S 4.26 Four Core Plus Earth BWTR06AA005CXLR x E BK BWTR07AA005CXLR x E BK BWTX01AA005 CXLR x E BK Core Colours No. Cores Colour 3 ( 4²) BN, Lt BU, GNYE 3 ( 6²) RD, BK, GNYE 4 ( 4²) BN, WH, Lt BU, GNYE 4 ( 6²) RD, NAT, BU, GNYE 5 ( 4²) BN, OG, WH, Lt BU, GNYE 5 ( 6²) RD, NAT, BU, BK, GNYE * Combined Earth Size Page 43

46 Titanex Multicore (H07RN-F) Cu conductors to DIN VDE 0295 Class 5, Cross-linked synthetic EPR rubber insulation and sheath (black), Lead free. 450/750V. Core identification to HD 308 S2. Pb Cores x Area ² Nom Dia Approx Mass Two Core HAR2X x Two Core Plus Earth HAR3G x E HAR3G x E HAR3G x E HAR3G x 4 + E HAR3G x 6 + E HAR3G x 10 + E HAR3G x 16 + E Three Core Plus Earth HAR4G x E HAR4G x E HAR4G x 4 + E HAR4G x 6 + E HAR4G x 10 + E HAR4G x 16 + E HAR4G x 25 + E HAR4G x 35 + E HAR4G x 70 + E Core Colours No. Cores Colour 2 BN, BU 3 BN, BU, GNYE 4 BN, BK, GY, GNYE continued Page 44

47 Titanex Multicore (H07RN-F) Cu conductors to DIN VDE 0295 Class 5, Cross-linked synthetic EPR rubber insulation and sheath (black), Lead free. 450/750V. Core identification to HD 308 S2. Pb Cores x Area ² Nom Dia Approx Mass Four Core Plus Earth HAR5G x E HAR5G x E HAR5G x 4 + E HAR5G x 6 + E HAR5G x 10 + E HAR5G x 16 + E HAR5G x 25 + E HAR5G x 35 + E Six Core Plus Earth HAR7G x E HAR7G x E Eleven Core Plus Earth HAR12G x E HAR12G x E Seventeen Core Plus Earth HAR18G x E Core Colours No. Cores Colour 5 BN, BK, GY, BU, GNYE 6 & above GNYE, BK with white numbering Page 45

48 Buflex X Prem Reeling Cable Cu conductors to IEC Class 5, XLPE insulation, Double layer anti-twisting reinforced polyurethane sheath. 0.6/1 kv. Includes central strength member. Pb Power Outer Max Approx Cores x Area Diameter Tensile Mass ² Min Max Load (N) Three Core Plus Earth BXP4G2.5 3 x E BXP4G4 3 x 4 + E BXP4G6 3 x 6 + E BXP4G10 3 x 10 + E BXP4G16 3 x 16 + E BXP3 x 25.3G6 3 x SE BXP3 x 35.3G6 3 x SE BXP3 x 50.3G10 3 x SE BXP3 x 70.3G16 ( 9376) 3 x SE BXP3 x 95.3G16 3 x SE BXP3 x 120.3G25 3 x SE BXP3 x 150.3G25 3 x SE BXP3 x 185.3G35 3 x SE BXP3 x 240.3G50 3 x SE BXP3 x 300.3G50 3 x SE Four Core Plus Earth BXP5G2.5 4 x E BXP5G4 4 x 4 + E BXP5G6 4 x 6 + E BXP5G10 4 x 10 + E BXP5G16 4 x 16 + E BXP5G25 4 x 25 + E BXP5G35 4 x 35 + E Core Colours No. Cores Colour 4 BN, BK, GY, GNYE 5 BN, BK, GY, BU, GNYE continued Page 46

49 Buflex X Prem Reeling Cable Cu conductors to IEC Class 5, XLPE insulation, Double layer anti-twisting reinforced polyurethane sheath. 0.6/1 kv. Includes central strength member. Control Cores x Area ² Outer Diameter Min Max Max Tensile Load (N) Approx Mass Conductor Size 1.5 ² BXP7 x x BXP12 x x BXP18 x x BXP24 x x BXP36 x x Conductor Size 2.5 ² BXP7 x x BXP12 x x BXP18 x x BXP24 x x BXP36 x x BXP42 x x Core Colours No. Cores Colour 7 & above WH with black numbering Page 47

50 Varolex Variable Speed Drive Cables Fixed Cu conductors, XLPE insulation, Laid up with three earths disposed in the interstices of the power cores, PVC bedding, Collective Cu tape screen, Black PVC sheath. 0.6/1 kv. Made to AS/NZS Cores x Area ² (combined earth size) Nom Dia Gland Size (Gland Type) Approx Mass FTDP07AA003CXRJ x E * (VSD) 0.32 FTDP09AA003CXRJ x SE (VSD) 0.44 FTDP11AA003CXRJ x SE (A4) 0.51 FTDP13AA003CXRJ x SE (A4) 0.62 FTDP15AA003CXRJ x SE (A4) 0.86 FTDC17AA003CXRJ x SE (A4) 1.21 FTDC18AA003CXRJ x SE (A4) 1.60 FTDC19AA003CXRJ x SE (A4) 2.11 FTDC20AA003CXRJ x SE S (A4) 2.77 FTDC21AA003CXRJ x SE (A4) 3.90 FTDC43AA003CXRJ x SE (A4) 4.67 FTDP24AA003CXRJ x SE S (A4) 5.85 FTDP25AA003CXRJ x SE (A4) 7.11 FTDC46AA003CXRJ x SE S (A4) 9.18 Core Colours No. Cores Colour 4 RD, WH, BU, GNYE Note: Conductors are circular stranded, sizes 16 ² and above are compact circular stranded. * Single Earth Page 48

51 PVC Flexible Control Flexible PVC insulation, Grey PVC sheath to DIN VDE 0281 part 1 and HD PVC self extinguishing and flame retardant. 300/500V. Cu conductors. Flexing -5ºC to 80ºC, fixed -40ºC to 80ºC. Min. bending radius 7.5 x cable o.d. Cores x Area ² Nom Dia Approx Mass Conductor Size 0.5 ² CC4G x E CC5G x E CC7G x E CC8G x E CC12G x E CC18G x E CC25G x E Conductor Size 0.75 ² CC3G x E CC4G x E CC5G x E CC7G x E CC12G x E CC18G x E CC42G x E Conductor Size 1.0 ² CC3G x E CC4G x E CC5G x E CC7G x E CC12G x E CC18G x E CC25G x E Note: Black cores with continuous white numbering according to DIN VDE 0293, plus green/yellow earth. Not suitable for open air applications. continued Page 49

52 PVC Flexible Control Flexible PVC insulation, Grey PVC sheath to DIN VDE 0281 part 1 and HD PVC self extinguishing and flame retardant. 300/500V. Cu conductors. Flexing -5ºC to 80ºC, fixed -40ºC to 80ºC. Min. bending radius 7.5 x cable o.d. Cores x Area ² Nom Dia Approx Mass Conductor Size 1.5 ² CC3G x E CC4G x E CC5G x E CC7G x E CC12G x E CC14G x E CC18G x E CC25G x E Conductor Size 2.5 ² CC3G x E CC5G x E CC7G x E CC12G x E Conductor Size 6 ² CC4G x 6 + E Note: Black cores with continuous white numbering according to DIN VDE 0293, plus green/yellow earth. Not suitable for open air applications. Page 50

53 PVC-EMC Flexible Control Flexible PVC insulation, Tinned Cu braid, Transparent PVC sheath. 300/500V. Cu conductors to DIN VDE 0295 class 5 and IEC class 5. Flexing -5ºC to 80ºC, fixed -40ºC to 80ºC. Min. bending radius 10 x cable o.d. Cores x Area ² Nom Dia Approx Mass Conductor Size 0.5 ² CY3G x E CY4G x E CY5G x E Conductor Size 0.75 ² CY3G x E CY4G x E CY5G x E CY12G x E Conductor Size 1.0 ² CY4G x E CY5G x E CY12G x E Conductor Size 1.5 ² CY3G x E CY4G x E CY7G x E Conductor Size 2.5 ² CY3G x E CY4G x E CY7G x E Conductor Size 4 ² CY5G x E Note: Black cores with continuous white numbering according to DIN VDE 0293, plus green/yellow earth. Not suitable for open air applications Page 51

54 Silicone Single Core Flexible tinned Cu conductors, Silicone insulation, Halogen free to IEC V. Fixed -60ºC to 180ºC. Min. bending radius 15 x cable o.d. Cores x Area ² Colour Nom Dia Approx Mass SIF23501A x 1.0 BK SIF23502A x 1.0 RD SIF2361.5BK x 1.5 BK SIF2361.5RDA x 1.5 RD SIF23701A x 2.5 BK SIF2372.5RD x 2.5 RD SIF2384BKA x 4 BK SIF2384RDA x 4 RD SIF2396BKA x 6 BK SIF2396RDA x 6 RD Page 52

55 Silicone Multicore Tinned Cu conductors, Silicone insulation, Brown Silicone sheath, Halogen free to IEC /500V. Fixed -60ºC to 180ºC (peak 220ºC). Min. bending radius 7.5 x cable o.d. Cores x Area ² Nom Dia Approx Mass Conductor Size 1.0 ² SF2X x SF3G x E SF4G x E SF7G x E SF12G x E Conductor Size 1.5 ² SF2X x SF3G x E SF4G x E SF5G x E SF12G x E Conductor Size 2.5 ² SF3G x E SF4G x E SF5G x E Conductor Size 6 ² SF4G x E Conductor Size 10 ² SF4G x 10 + E Core Colours No. Cores Colour 2 BN, BU 3 BN, BU, GNYE 4 BN, BU, BK, GNYE 5 BN, BU, BK, GY, GNYE 6 & above BK with white numbering Page 53

56 Instrolex Instrumentation Cable Plain annealed Cu conductors, V-90 RP PVC insulation, Twisted pairs, Al/Polyester screen, Stranded tinned annealed Cu drain wire, Rip cord, 5V-90 RP Black PVC sheath. Overall Screen (CS) Area ² No. Pairs Nom Dia Gland Size A2 or A2F Approx Mass Conductor Size 0.5 ² IEB183AA001CXAA S/ IEC183AA002CXAA S 0.06 * IEC183AA004CXAA S 0.09 * IEC183AA006CXAA S 0.13 IEC183AA008CXAA IEC183AA010CXAA IEC183AA012CXAA IEC183AA016CXAA IEC183AA020CXAA IEC183AA024CXAA * IEC183AA036CXAA * Conductor Size 1.5 ² IEB184AA001CXAA S/ * IEC184AA002CXAA * IEC184AA004CXAA IEC184AA006CXAA * IEC184AA008CXAA IEC184AA010CXAA * IEC184AA012CXAA IEC184AA036CXAA IGB184AA001CXAA Triple S/ * 0.5 ² is equalivalent to 7/0.30 and 20 AWG 1.5 ² is equalivalent to 7/0.50 and 16 AWG * Also available as intrinsically safe blue sheathed Instrolex Page 54

57 Instrolex Instrumentation Cable Plain annealed Cu conductors, V-90 RP PVC insulation, Twisted pairs, Al/Polyester screen, Stranded tinned annealed Cu drain wire, Rip cord, 5V-90 RP Black PVC sheath. Individual and Overall Screen (ESCS) Area ² No. Pairs Nom Dia Gland Size A2 or A2F Approx Mass Conductor Size 0.5 ² IED183AA002CXAA S 0.07 * IED183AA004CXAA IED183AA006CXAA IED183AA008CXAA IED183AA010CXAA IED183AA012CXAA IED183AA016CXAA IED183AA024CXAA Conductor Size 1.5 ² IED184AA002CXAA IED184AA004CXAA IED184AA012CXAA IED184AA016CXAA ² is equalivalent to 7/0.30 and 20 AWG 1.5 ² is equalivalent to 7/0.50 and 16 AWG * Also available as intrinsically safe blue sheathed Instrolex Page 55

58 Instrolex Instrumentation Cable Plain annealed Cu conductors, V-90 RP PVC insulation, Twisted pairs, Al/Polyester screen, Stranded tinned annealed Cu drain wire, Rip cord, PVC bedding, Steel wire armour, 5V-90 RP Black PVC sheath. Overall Screen, Steel Wire Armour (CS SWA) Nom Area No. Dia ² Pairs Gland Size CW or E1FW Approx Mass Conductor Size 0.5 ² IEG183AA002CXAA S 0.25 * IEG183AA004CXAA S 0.28 IEG183AA006CXAA S 0.36 IEG183AA008CXAA S 0.42 IEG183AA010CXAA IEG183AA012CXAA * IEG183AA016CXAA IEG183AA024CXAA Conductor Size 1.5 ² IEF184AA001CXAA S/ * IEG184AA002CXAA S 0.34 IEG184AA006CXAA IGF184AA001CXAA Triple S/ * Individual and Overall Screen, Steel Wire Armour (ESCS SWA) Nom Area No. Gland Approx Dia ² Pairs Size Mass CW or E1FW Conductor Size 0.5 ² IEH183AA002CXAA S 0.26 * IEH183AA004CXAA S 0.35 IEH183AA006CXAA IEH183AA008CXAA IEH183AA010CXAA IEH183AA012CXAA * IEH183AA024CXAA * IGH183AA012CXAA Triple ² is equalivalent to 7/0.30 and 20 AWG 1.5 ² is equalivalent to 7/0.50 and 16 AWG * Also available as intrinsically safe blue sheathed Instrolex Page 56

59 PVC Flat Crane Cable PVC insulation, Black PVC sheath. 450/750V. Cores x Area ² Outer Dim Approx Mass Power FC4G4-3 x 4 + E 6.5 x FC4G6-3 x 6 + E 7.0 x FC4G10-3 x 10 + E 9.0 x FC4G16-3 x 16 + E 11.0 x FC4G25-3 x 25 + E 13.5 x FC4G35-3 x 35 + E 14.8 x FC5G x 6 + E 7.0 x FC7G x 4 + E 6.5 x Control FC4G x E 5.0 x FC4G2.5-3 x E 6.0 x FC5G1.5-4 x E 5.0 x FC5G2.5-4 x E 6.0 x FC8G1.5-7 x E 5.0 x FC8G x E 6.0 x FC12G x E 5.0 x FC12G x E 6.0 x FC16G x E 5.0 x FC18G x E 4.5 x FC24G x E 4.3 x Page 57

60 Notes Page 58

61 Page 59

62 Security Cable Unscreened Stranded Cu conductor, PVC insulation, Cores laid up, White PVC sheath. No. Cores Nom Dia Max DC 20ºC Ohms/km Pack Size * Approx Mass Conductor Size 0.22 ² (7/0.20) JSC.2WT4C m 0.01 JSC.2WT6C m 0.03 Conductor Size 0.44 ² (14/0.20) JSC.5WT4C m 0.03 JSC.5WT6C* A, B 0.05 JSC.5WT8C* A, D 0.06 Screened Stranded Cu conductor, PVC insulation, Cores laid up, Aluminium foil overall tape, Stranded tinned annealed Cu drain wire, Grey PVC sheath. No. Cores Nom Dia Max DC 20ºC Ohms/km Pack Size Approx Mass Conductor Size 0.44 ² (14/0.20) JSS.5GY7C m 0.07 Core Colours No. Cores Colour 4 RD, BU, WH, BK 6 RD, BU, WH, BK, YW, GN 7 RD, BU, WH, BK, OG, YW, GN 8 RD, BU, WH, BK, VT, YW, GN, BN * Pack Size Reference Size A 100m Spool 1 B 250m Spool 250 D 500m Spool 5 E 200m Box B20 F 300m Box B30 Page 60

63 Audiolex High Definition (HD) Vision RG59 coaxial cable with braid (95% coverage). 3 and 6 core includes 4 x 0.2² PVC control cores, White PVC sheath. No. Cores Control Coaxial Core Nom Dia Nom Dia Nom Dia Pack Size Approx Mass JPLAS3PREMA m 0.16 JPLAS6PREMA m 0.29 Oxygen Free Copper (OFC) Audio Stranded Cu conductor, PVC insulation, Violet PVC sheath. Cores x Area ² Stranding No./ Nom Dia Nom Con. 20ºC Ohm/km Pack Size * Approx Mass Two Core JTS1.2VT2CA x / m 5.8 JTS2.5VT2C* x / A, C 10.0 JTS4VT2CA x / m 16.0 Four Core JTS1.2VT4CA x / m 8.6 JTS2.5VT4CA x / m 17.0 JTS4VT4CA x / m 27.0 * Pack Size Reference Size A 100m Spool A1 C 300m Spool A3 Page 61

64 Figure 8 Speaker Trurip Flexible Cu conductors, PVC insulation. Standard Cores x Area ² Colour Nom Dim Max DC 20ºC Ohms/km Approx Pack Mass Size * Conductor Size 0.50 ² (14/0.20) JSF.5WTBK x 0.5 BK/WH 1.8 x m 0.02 JSF.5GYBK* x 0.5 GY/BK 1.8 x A, D 0.02 Conductor Size 0.75 ² (24/0.20) JSF.75BKWT* x 0.75 BK/WH 2.9 x B, D 0.03 JSF.75BEWT x 0.75 BU/WH 2.9 x m 0.03 JSF.75RDBK* x 0.75 RD/BK 2.9 x A, B, D 0.03 JSF.75CL x 0.75 Clear 2.9 x m 0.03 JSF.75BK x 0.75 BK 2.9 x m 0.03 JSF.75WT x 0.75 WH 2.9 x m 0.03 Oxygen Free Copper Cores x Area ² Colour Nom Dim Max DC 20ºC Ohms/km Pack Size Approx Mass JSF1.0CL x 1.0 Clear 2.6 x m 0.03 JSF2.0CL* x 2.0 Clear 3.4 x A, D 0.05 JSF2.6CL x 2.6 Clear/RD 4.5 x m 0.08 Stranding No./ JSF1.0CL 91/0.12 JSF2.0CL* 64/0.20 JSF2.6CL1 84/0.20 * Pack Size Reference Size A 100m Spool 1 B 250m Spool 250 D 500m Spool 5 Page 62

65 Coaxial Cable Tinned or plain Cu conductor, solid PE insulation, tinned Cu wire braid, Black PVC sheath. Coaxial 50 0hm Type Stranding No./ Nom Dia Pack Size Approx Mass JBCRG58CUMIL RG58 19/0.18 T/C m 0.04 JBCRG213MIL RG213 7/0.7 B/C m 0.16 Electrical Characteristics Shielding Dielectric Max DC 20ºC Ohm/km Nom Cap pf/m Nom Velocity Prop % JBCRG58CUMIL1 95% T/C Solid PE JBCRG213MIL1 97% B/C Solid PE continued Page 63

66 Coaxial Cable Plain annealed Cu conductor, PE insulation, Cu wire braid (either 85% or 95% coverage), Black PVC sheath. Coaxial 75 0hm Type Stranding No./ Nom Dia Pack Size * Approx Mass RG59 Closed Circuit Television (CCTV) JBCRG59BUCCTV* 3179 RG59 1/ A, B, D 0.05 JBCRG59PREMA RG59 1/ m 0.06 RG6 TV Antenna / TV Lead-in JBCRG6QUAD* 5921 RG6 1/ A, F 0.05 Electrical Characteristics Shielding Dielectric Max DC Nom Resist. Nom Cap 20ºC pf/m Ohm/km Prop % JBCRG59BUCCTV 86% B/C Braid Solid PE JBCRG59PREMA1 95% B/C Braid Solid PE Quad Shield JBCRG6QUAD Al Foil, 60% Braid Foamed PE Al Foil, 40% Braid * Pack Size Reference Size A 100m Spool 1 B 250m Spool 25 D 500m Spool 5 F 300m Box B30 Page 64

67 Composite Coaxial & Control Core RG59 coaxial with braid (85% coverage) with two 24/0.20 power cores, PVC insulation positioned either side of coaxial, Black PVC sheath. 250V/250V. Nom Dim Nom Ins Thickness Max DC 20ºC Ohms/km Pack Size * Approx Mass JCOMP85* x A, B, D 0.12 * Pack Size Reference Size A 100m Spool A1 B 250m Spool BA25 D 500m Spool BA5 Page 65

68 LAN Cu conductor, Polyolefin insulation, Twisted pairs, PVC sheath. Compatible with RJ type connector. No. Pairs Area ² Sheath Nom Dia Pack Size Approx Mass Category 5E (Solid) CAT5E04RDB RD m Box 0.03 CAT5E04YWB YE m Box 0.03 Category 5E (Underground) JCAT5EFPA BK m Spool 0.03 Category 5E (Screened) JCAT5ESCRB GY m Box 0.05 Category 6 JCAT604GYB GY m Box 0.04 Description Stranding No./ Max DC 20ºC Ohm/km Nom Imped. Ohms Mutual Cap pf/m Category 5E (Solid) 1/ Category 5E (Underground) 1/ Category 5E (Screened) 1/ Category 6 1/ Page 66

69 Optical Fibre Nylon Underground Des. No. Fibres Nom Dia Max Pulling Tension kn Min Bending Radius During Installation Installed Single Mode (OS1) FIB06SMJN /125 µm SM FIB12SMJN /125 µm SM FIB24SMJN /125 µm SM Multi Mode (OM1) FIB06MMJN /125 µm MM FIB08MMJN /125 µm MM FIB12MMJN /125 µm MM FIB24MMJN /125 µm MM Page 67

70 Telephone Internal Solid Cu conductor, PVC insulation, Cream PVC sheath. No. Pairs Wire Size Nom Dia Pack Size Approx Mass TINT002AA m 0.01 TINT025A Bulk 0.18 TINT002B Quad m Box TBC Pair Colours Pair No. Wire 1 Wire 2 Pair No. Wire 1 Wire 2 1 WH BU 14 BK BN 2 WH OG 15 BK GY 3 WH GN 16 YE BU 4 WH BN 17 YE OG 5 WH GY 18 YE GN 6 RD BU 19 YE BN 7 RD OG 20 YE GY 8 RD GN 21 PU BU 9 RD BN 22 PU OG 10 RD GY 23 PU GN 11 BK BU 24 PU BN 12 BK OG 25 PU GY 13 BK GN Note: TINT002 colour sequence is WH/BU, RD/BK. Page 68

71 Telephone External Aerial Solid Cu conductor, Polyethylene insulation, Twisted unit pair, Black polyethylene sheath incorporating a galvanised solid high tensile steel bearer wire in figure 8 construction. 10 Pair has aluminium foil screen and stranded drain wire for high interference areas. Wire Nom Max DC Approx No. Resist. Pack Size Dim Mass 20ºC Size Ohm/km TEXT64IB002A x m 0.05 Underground Solid Cu conductor, Polyethylene insulation, Twisted unit pair jelly filled, Paper tape wrap, Black polyethylene sheath. No. Pairs Wire Size Nom Dia Max DC 20ºC Ohm/km Pack Size * Approx Mass TEXT64FP002* A, D, G 0.03 TEXT64FP Bulk 0.06 TEXT64FP Bulk 0.13 Pair Colours Pair No. Wire 1 Wire 2 Pair No. Wire 1 Wire 2 1 WH BU 6 RD BU 2 WH OG 7 RD OG 3 WH GN 8 RD GN 4 WH BN 9 RD BN 5 WH GY 10 RD GY * Pack Size Reference Size A 100m Spool A1 D 500m Spool A5 G Bulk Page 69

72 Garden Lighting Figure 8, Stranded Cu conductors, Black PVC insulation (parallel web), Water resistant. Cores x Area Standing Nom Dim Pack ² No./ Size JSF1.3GLBK x / x m JSF4GLBK x 4 84/ x m JSF6GLBK x 6 81/ x m JSF10GLBK x / x m Approx Mass Max DC 20ºC Ohm/km Voltage Drop Single 45ºC mv/a.m JSF1.3GLBK JSF4GLBK JSF6GLBK JSF10GLBK Page 70

73 Fire Alarm Cable Analogue Stranded Cu conductor, PVC insulation, Twisted Pair, PVC sheath. 450/750V. Cores x Area Standing Pack ² No./ Size QACR50A2002GXJB x 1.25 (RD) 16/ m QACR50A2002GXHF x 1.25 (GY) 16/ m Nom Dia Max DC 20ºC Ohm/km Approx Mass QACR50A2002GXJB QACR50A2002GXHF Halogen Free Fire Alarm System Telecounication Cable Solid Cu conductor, Silicone insulation, Glass fibre tape, Laminated aluminium tape screen, Solid tinned Cu drain wire, Halogen free flame retardant sheath. No. Nom Dim Pack Approx Mass Pairs Size OLX x 0.8 Bulk 0.07 Page 71

74 Data Cables RS422 Screened Data (Pair) Stranded tinned Cu conductors, HDP insulation, Aluminium foil overall tape screened with a stranded drain wire, Cream PVC sheath. Material No. No. of Pairs Stranding No./ Nom Dia Max DC 20ºC Ohms/km Nom. Pair Cap. pf/m Approx Mass JD1PS / JD2PS / JD3PS / JD4PS / Pair Colours Pair No. Wire 1 Wire 2 Pair No. Wire 1 Wire 2 1 WH BU 4 WH BN 2 WH OG 5 WH GY 3 WH GN 6 RD BU RS232 Screened Data (Cores) Stranded tinned Cu conductors, PVC insulation, Cores laid up, Aluminium foil overall tape screened with a stranded drain wire, Grey PVC sheath. No. of Cores Stranding No./ Nom Dia Max DC 20ºC Ohms/km Pack Size Approx Mass Conductor Size 0.22 ² JD6CSAAA / m 0.04 Conductor Size 0.5 ² SD2CSA / m Box 0.02 SD3CSA / m Box 0.02 Core Colours No. Cores Colour No. Cores Colour 1 RD 5 WH 2 BU 6 BK 3 GN 7 BN 4 YE 8 VT Page 72

75 The cables New Zealanders trust to stay safe and secure have a new name Alsecure. Alsecure is now the name to specify for the cables you ve always relied on for safety and security to maintain circuit integrity for lighting, alarms, pumps and other essential services, even under fire. Page 73

76 Alsecure Premium Ceramifiable Single Core Cu conductor, Ceramifiable insulation, Black HFS-110-TP sheath to AS/NZS ºC. 0.6/1 kv. WS52W fire rate to AS/NZS 3013:2005 Area ² Nom Ins Thick Nom Sheath Thick Nom Dia Approx Mass PEKP15AA001CXAA PEKP17AA001CXAA PEKP18AA001CXAA PEKP19AA001CXAA PEKP20AA001CXAA PEKP22AA001CXAA PEKP23AA001CXAA PEKP24AA001CXAA PEKP25AA001CXAA PEKP26AA001CXAA PEKP28AA001CXAA PEKP30AA001CXAA PEKP32AA001CXAA Page 74

77 Alsecure Premium Ceramifiable Multicore Cu conductor, Ceramifiable insulation, Orange HFS-110-TP sheath to AS/NZS ºC. 0.6/1 kv. WS52W fire rated to AS/NZS 3013:2005. Cores x Area ² Nom Dia Approx Mass Two Core PEKP07AA002OMAA x Two Core Plus Earth PDKP05AA002OMAA x E PDKP07AA002OMAA x E PDKP09AA002OMAA x 4 + E PDKP11AA002OMAA x 6 + E PDKP13AA002OMAA x 10 + E Three Core Plus Earth PDKP05AA003OMAA x E PDKP07AA003OMAA x E PDKP09AA003OMAA x 4 + E PDKP11AA003OMAA x 6 + E PDKP13AA003OMAA x 10 + E PDKP15AA003OMAA x 16 + E Four Core Plus Earth PDKP05AA004OMAA x E PDKP07AA004OMAA x E PDKP09AA004OMAA x 4 + E PDKP11AA004OMAA x 6 + E PDKP13AA004OMAA x 10 + E PDKP15AA004OMAA x 16 + E PDKP17AA004OMAA x 25 + E PDKP18AA004OMAA x 35 + E PDKP19AA004OMAA x 50 + E Page 75

78 Alsecure Premium FRP Ceramifiable Stranded Plain Annealed Copper conductor, HFI-90-TP Ceramifiable Insulated, twisted pairs black and white numbered, overall screened with aluminium polyester laminate tape plus Stranded Tinned Annealed Copper drain wire, Red HFS-90-TP Sheathed Alsecure FRP Cable, 90ºC, WS51W Fire rated to AS/NZS 3013:2005. Number of Pairs Nom. overall cable dia () Approx Mass Conductor 0.75² PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA PBKP03AA Conductor 1.5² PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA PBK184AA Page 76

79 Alsecure Premium Flex Ceramifiable Cu conductor, flexible X-HF-110 XLPE insulation, Black HFS-110-TP sheath to AS/NZS ºC. 0.6/1 kv. WS52W fire rated to AS/NZS 3013:2005. Area Nom Dia Approx Mass ² PEKX01AA PEKX02AA PEKX03AA PEKX04AA PEKX05AA PEKX06AA PEKX07AA PEKX08AA PEKX09AA PEKX10AA PEKX11AA PEKX68AA PEKX69AA PEKX70AA PEKX71AA Page 77

80 Page 78

81 AAC Aerial Conductors Bare Aluminium conductor. Made to AS Cross Sec. Area ² Stranding No./ Nom Dia Approx Mass Namu / Poko / Ladybird / Kutu / Fly / Rango / Grasshopper / Wasp / Beetle / Weke / Bee / Cricket / Weta / Mata / Cockroach / Butterfly / Centipede / Cicada / Covered Aluminium conductor, PVC covered. Made to AS/NZS Name Cross Sec. Area ² Stranding No./ Nom Dia Approx Mass BAAB53AA001CXAA 4373 Namu CVD / Ladybird CVD / BAAB32AA001CXAA 3416 Kutu CVD / BAAB57AA001CXAA 4421 Fly CVD / BAAB59AA001CXAA 9751 Rango CVD / BAAB61AA001CXAA 5605 Wasp CVD 106 7/ BAAB66AA001CXAA 5912 Beetle CVD / BAAB36AA001CXAA 5032 Weke CVD 122 7/ BAAB67AA001CXAA 2395 Weta CVD / Page 79

82 AAAC Aerial Conductors Bare 1120 Aluminium alloy conductor. Made to AS Cross Sec. Area ² Stranding No./ Nom Dia Approx Mass Chlorine / Chlorine GC / Flurone / Flurone GC / Helium / Helium GC / Hydrogen / Hydrogen GC / Iodine / Iodine GC / Krypton / Krypton GC / Neon / Neon GC / Nitrogen GC / GC = Greased core Covered 1120 Aluminium alloy conductor, PVC covered. Made to AS/NZS Name Cross Sec. Area ² Stranding No./ Nom Dia Approx Mass BAAJ80AA001CXAA 8169 Fluorine CVD / BAAJ60AA001CXAA 8662 Hydrogen CVD 111 7/ BAAJ85AA001CXAA 8585 Krypton CVD / Page 80

83 ACSR Aerial Conductors Bare Aluminium conductor, galvanised steel reinforced. Made to AS Equ Alu Cross Sec Area Stranding No./ Nom Dia Approx Mass ² Ali Steel Magpie /2.11 4/ Squirrel /2.11 1/ Gopher /2.36 1/ Ferret /3.00 1/ Mink /3.66 1/ Raccoon /4.09 1/ Dog /4.72 7/ Dingo /3.35 1/ Wolf /2.59 7/ Jaguar /3.86 1/ Goat /3.71 7/ Covered Aluminium conductor, galvanised steel reinforced, PVC covered. Made to AS/NZS Name Equ Al Cross Sec Area Stranding No./ Nom Dia Approx Mass ² Ali Steel BAAM39AA001CXAA 8620 Squirrel CVD /2.11 1/ BAAM01AA001CXAA 5504 Ferret CVD /3.00 1/ Page 81

84 Al Aerial Bundled Cables (ABC) Aluminium conductor, XLPE insulation. Made to AS/NZS Cores x Area ² Cond. Dia Ins. Thick. Nom Dia of Bundle Approx Mass Two Core XDAB17AA002AALL x XDAB18AA002AALL x XDAB19AA002AALL x XDAB22AA002AALL x Three Core XDAB18AA003AALM x Four Core XDAB17AA004AALP x XDAB18AA004AALP x XDAB19AA004AALP x XDAB20AA004AALP x XDAB22AA004AALP x Four Core Plus Pilot XDAB18AAP04AALP x P XDAB20AAP04AALP x P XDAD22AAP04AALP x P XDAB22AAL04AALP x P (x2) Page 82

85 Al Binder Wire Bare Solid aluminium wire. Made to OS 19:2001 (Olex Standard). Wire Dia Approx Mass ACBL47AA001AAAA ACBL36AA001AAAA ACBL39AA001AAAA ACBL42AA001AAAA Covered Solid aluminium wire, PVC covered. Made to OS 18:2001 (Olex Standard). Wire Dia Approx Mass ACCL47AA001BKAA ACCL36AA001BKAA Page 83

86 Cu Aerial - Hard Drawn Bare Cu conductor. Made to AS Area ² Stranding No./ Nom Dia Approx Mass ACUT11AA001AAAA / ACUT75AA001AAAA / ACUT13AA001AAAA / ACUT15AA001AAAA / ACUT17AA001AAAA / ACUT18AA001AAAA / ACUT70AA001AAAA / ACUT19AA001AAAA / ACUT20AA001AAAA / ACUT22AA001AAAA / Covered Cu conductor, PVC cover. Made to AS/NZS Area ² Stranding No./ Nom Cover Thick Nom Dia Approx Mass BAAT11AA001AABK / BAAT13AA001AABK / BAAT15AA001AABK / BAAT16AA001AABK / BAAT18AA001AABK / BAAT70AA001AABK / BAAT19AA001AABK / BAAT20AA001AABK / BAAT22AA001AABK / Page 84

87 Cu Aerial - Trurip Cu conductor, PVC insulation. Made to AS/NZS Cores x Area ² Nom Dia Approx Mass DAAT15AA002AABK x FAAT15AA003AABK x Cu Aerial - Neutral Screens Cu conductor, PVC insulation, Cu neutral screen, PVC sheath. Made to AS/NZS Cores x Area ² Nom Dia Approx Mass Single Core BAGT11AA001CXRD x BAGT15AA001CXRD x Two Core QDAT15AA001CXRD x P DAET15AA002CXAB x Three Core QDHT15AA002CXRD x P FAGT11AA003CXRJ x FAGT13AA003CXRJ x FAGT15AA003CXRJ x Four Core QDHT15AA003CXRJ x P (x 2) Page 85

88 Cu Binder Wire Bare Solid Cu wire. Made to OS 19:2001 (Olex Standard). Wire Dia Approx Mass ACUL03A2001AAAA ACUL04A2001AAAA ACUL08A1001AAAA Covered Solid Cu wire, PVC covered. Made to OS 18:2001 (Olex Standard). Wire Dia Approx Mass ACCL03A1001AABK ACCL04A1001AABK ACCL08A1001AABK ACCL0A19001AABK Page 86

89 Notes Page 87

90 Page 88

91 Glands A2 Industrial Glands - Sets Indoor/outdoor gland for all types of unarmoured cable providing a seal on the outer sheath. Gland Sets include a locknut and sealing washer. Gland Cable Dia () Shroud Size min A max Ref GLAND674 A2 20S/16 (SET) GLAND979 A2 20S (SET) GLAND005 A2 20 (SET) GLAND333 A2 25 (SET) GLAND224 A2 32 (SET) GLAND431 A2 40 (SET) GLAND615 A2 50S (SET) GLAND701 A2 50 (SET) /230 GLAND860 A2 63S (SET) GLAND442 A2 63 (SET) A2F Dual Certified EEx d & EEx e Glands Indoor and outdoor cable gland for use in Zone 1, 2, 21 and 22 Hazardous Areas with all types of unarmoured cable, providing a flameproof seal on the cable outer sheath. Gland Cable Dia () Shroud Size min A max Ref GLAND919 A2F 20S/ TBC GLAND028 A2F 20S GLAND918 A2F GLAND676 A2F GLAND671 A2F GLAND511 A2F GLAND100 A2F /230 GLAND277 A2F 63S VSD Glands For use with Varolex cables. Gland Cable Dia () Shroud Size min max Ref GLAND020 VSD Page 89

92 Glands A4 Industrial Glands For use with Varolex cables. Indoor and outdoor cable gland for all types of steel tape armour (STA) cable providing a seal on the cable outer sheath and a continuity seal on the tape armour. Gland Cable Dia () Cable Dia () Shroud Size min A max min B max Ref GLAND247 A GLAND530 A GLAND823 A GLAND610 A4 50S GLAND135 A GLAND437 A4 63S GLAND531 A CW Industrial Glands - Sets Indoor and outdoor gland for all types of SWA cable, providing environmental seal on the cable outer sheath. The gland also provides mechanical cable retention and electrical continuity via armour wire termination. Gland Sets include a locknut and sealing washer. Cable Cable Dia Wire Armour Gland Shroud Dia () () () Size Ref A max min B max min max GLAND830 CW 20S/16 (SET) GLAND572 CW 20S (SET) GLAND780 CW 20 (SET) GLAND428 CW 25 (SET) GLAND210 CW 32 (SET) GLAND561 CW 40 (SET) GLAND332 CW 50S (SET) GLAND731 CW 50 (SET) GLAND976 CW 63 (SET) GLAND865 CW 75S (SET) GLAND703 CW 75 (SET) Page 90

93 Glands E1FW Dual Certified EEx d & EEx e Glands Indoor and outdoor cable gland for use in Zone 1, 2, 21 and 22 Hazardous Areas with all types of SWA cable providing a flameproof seal on the cable inner sheath and an environmental seal on the cable outer sheath. Cable Dia Cable Dia Wire Armour Gland Shroud () () () Size Ref min A max min B max min max GLAND978 E1FW 20S/ GLAND770 E1FW 20S GLAND766 E1FW GLAND008 E1FW GLAND999 E1FW GLAND658 E1FW GLAND982 E1FW 50S GLAND436 E1FW GLAND018 E1FW 63S CX/Z Industrial Glands Indoor and outdoor cable gland for all types of braided or steel tape armour (STA) cables providing environmental seal on the cable outer sheath. The gland also provides mechanical cable retention and electrical continuity via wire braid or tape armour termination. Gland Size Cable Dia () A max Cable Dia () min B max Armour Range Grooved Max () Shroud Ref GLAND742 CX/Z 20S/ GLAND174 CX/Z 20S GLAND651 CX/Z GLAND125 CX/Z GLAND862 CX/Z GLAND221 CX/Z GLAND533 CX/Z 50S GLAND231 CX/Z Page 91

94 Glands PX2K Flameproof EEx d Glands For all types of armoured cables providing an inner Flameproof compound compound barrier seal around the individual cable cores and an environmental seal on the cable outer sheath. Also equipped with an integral Deluge Protection seal to prevent premature armour corrosion and an armour clamping facility suitable for SWA, Braided or Steel Type cables. The cable gland also provides electrical continuity via armour termination. Suitable for use in Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Areas. Gland Size Cable Dia () A max Cable Dia () min B max Wire Armour () min max GLAND260 PX2K 20S GLAND190 PX2K GLAND162 PX2K 25S GLAND120 PX2K GLAND089 PX2K GLAND051 PX2K GLAND338 PX2K 50S GLAND460 PX2K Gland Accessories Entry Thread Entry Thread Locknuts Earth Tags Size Seals 20 GLAND433 GLAND666 GLAND GLAND102 GLAND209 GLAND GLAND568 GLAND082 GLAND GLAND110 GLAND226 GLAND GLAND308 GLAND319 GLAND GLAND863 GLAND523 GLAND GLAND099 GLAND186 GLAND180 Page 92

95 Glands PVC Shrouds Shroud Ref 02 GLAND GLAND GLAND GLAND GLAND GLAND GLAND GLAND GLAND GLAND192 17/230 GLAND GLAND GLAND GLAND GLAND GLAND GLAND458 Page 93

96 Notes Page 94

97 Page 95

98 General Technical Information Installation Information General All cables must be installed to comply with the latest New Zealand Wiring Regulations. Moisture Olex cables are manufactured in conditions that exclude moisture, as it is difficult to remove from a finished cable. It is important that precautions are taken during installation to ensure that moisture is not permitted to enter the cable. Cut ends or opened areas must be protected from moisture at all times, including during pulling in. Cables, after cutting, must be re-sealed for storage, by an effective method such as a heat shrinkable cable cap. Single Core Cables The following points relating to single core cables should be noted: 1. Single core cables carrying the phase currents of a single circuit must be installed as closely as possible together, to minimise inductive reactance and voltage drop. The preferred formation for three phase conductors is a "trefoil" or cloverleaf pattern although flat touching formation is also acceptable. Sheaths should be in contact with one another in either case. 2. A single core cable generates an alternating magnetic field around itself which can cause large increases in voltage drop and power loss due to "transformer effect" when ferrous metal (iron and steel) is allowed to encircle the cable. Steel racking or ladder will not induce this effect, but the following must be observed: a. Cable cleats may be of wood, plastic, or non-ferrous metal but steel saddles should not be used on single cores. b. Where three single phase cables pass through a steel bulkhead, they must all pass through the same hole. Where glanding is required, it is usual to cut out a panel and replace this with a non-ferrous (metal or plastic) plate in which the three or four glands are mounted. Cable Support Under fault conditions, single core cables used as phase conductors in a multi-phase system may be subjected to large electromechanical forces which tend to drive them apart. Generally, properly designed cleats spaced at 1500 intervals will provide adequate support to the cable under normal operating conditions. However special consideration may be required if fault currents in excess of 15 ka are anticipated. continued Page 96

99 General Technical Information Installation Information (continued) Green Goo Also known as Green Slime, this phenomenon is characterised by the appearance of a sticky green exudate leaking out of PVC-insulated wiring at locations such as switches, hot points and light fittings. It is a coon occurrence in both Australia and New Zealand. The green goo problem is predominantly associated with older (25+ years) TPS-type cables operating in a warm environment. The exudate comprises a plasticiser that has migrated out of the PVC insulation, coloured due to reaction with the copper conductor, and that has subsequently travelled - by capillary action and/or gravity along the conductor to emerge at a termination point. Due to its stickiness and unsightly colour, the goo has a high nuisance value, however it poses no significant health hazard. It may be cleaned from surfaces by wiping with a rag soaked in a petroleum- or alcohol-based solvent (such as meths). The long-term consequence of the exudate is that it represents a de-plasticising of the insulation, meaning that as the process continues, the PVC will eventually become brittle, and crack. TPS Cables in Polystyrene Thermal Insulation With the increasing use of polystyrene block insulation in houses and caravans, it is important to explain the potential problem that arises when PVC sheathed and insulated cables come into direct contact with this material. The plasticiser that is added to PVC to make it flexible has a tendency to migrate out of the PVC and into materials with which it is in contact, particularly where those materials such as polystyrene and polyurethane - have a great affinity for the plasticiser. This will lead to the PVC s becoming progressively harder and more brittle, while in contrast the polystyrene will appear to melt as it absorbs the plasticiser. The rate of migration is dependent upon the relative thickness of the materials, the temperature, and the amount of surface area in direct contact. Accordingly, the rate of deterioration of the PVC cable can vary considerably under different circumstances. To mitigate the problem it is recoended that the amount of direct contact between the cable and the polystyrene be reduced as much as possible. Effective ways of achieving this include positioning the cable with an air gap between the sheath and the polystyrene, or installing the cable within a rigid PVC or PE conduit. continued Page 97

100 General Technical Information Installation Information (continued) UV Resistance Many polymers, due to their molecular structure, are prone to attack by UV radiation, and because of this will degrade upon continued exposure to sunlight, eventually cracking and splitting. The polyolefin family of materials, such as PE (including XLPE or X-90) and PP is particularly susceptible to deterioration in this manner. PVC is also at risk but noticeably less so, partly because of its structure but also due to the mitigating effects of the fillers, plasticisers and stabilisers that are compounded with it. A simple, effective and cheap material that can be added to plastic compounds to absorb UV radiation is carbon black. However, while this approach is appropriate for sheathing materials, it is not necessarily so for insulating materials as the carbon masks the core colour. Olex New Zealand Limited recoends that the insulation of its cables be protected (covered) from solar radiation at all times, except in those instances where the material has been deliberately modified to guard against the effects of UV, eg, Aerial Bundled Cables (ABC). This covering may simply be the sheath of the cable. Lugs and Links Stranded compacted conductors, either round or sector shaped, must have lugs and links fitted that are manufactured for the same nominal cross-sectional area as the conductor. For example, a 150 ² conductor must have a 150 ² lug or link fitted, and the correct dies, as stated by the manufacturer, used to compress it. Although the lug or link will appear to be loose on the conductor, this is simply because the initial compression of the joint has already taken place during the manufacture of the conductor; the final compression of the joint will be correct. If, for example, a 120 ² lug or link was fitted to a 150 ² conductor, the joint would be over-compressed and likely to fail in service. In addition, the smaller lug in itself would be unable to carry the same maximum current as the larger conductor, particularly with respect to fault currents. Olex New Zealand Limited manufactures conductors to be compatible with lugs and links normally available in New Zealand. Page 98

101 General Technical Information Minimum Spacings in Air to Avoid Derating Table 1A - Minimum Spacings in Air to Avoid Derating Method of Installation Horizontal Spacings Vertical Spacings Single Core Cables Cables spaced away from surfaces and supported on ladders, racks, etc. or suspended from a catenary wire, such that impedance to air flow around the cables is not greater than 10%. Cables spaced away from surfaces and supported on perforated or unperforated trays such that air flow around the cables is partially restricted. D D 2D 2D D 4D 4D 4D Cables fixed directly to a wall, floor, ceiling or similar surface such that air circulation is restricted. 2D 2D 6D 6D continued Page 99

102 General Technical Information Minimum Spacings in Air to Avoid Derating (continued) Table 1B - Minimum Spacings in Air to Avoid Derating Method of Installation Horizontal Spacings Vertical Spacings Multicore Cables Cables spaced away from surfaces and supported on ladders, racks, etc. or suspended from a catenary wire, such that impedance to air flow around the cables is not greater than 10%. Cables spaced away from surfaces and supported on perforated or unperforated trays such that air flow around the cables is partially restricted. Cables fixed directly to a wall, floor, ceiling or similar surface such that air circulation is restricted. D 0.5D 2D 2D 2D 6D 4D 4D 4D Page 100

103 General Technical Information Single Core Cables in Parallel The following are the recoended arrangements of single core cables in parallel. Nonsyetrical arrangements result in different impedances and hence unequal current sharing between parallel legs of the same phase. This should be avoided as it could lead to overheating of some cables. Neutral conductors of Three phase circuits should be located so as not to disturb the syetry of the groups. Table 2 Arrangements for Equal Current Sharing of Single Core Cables in Parallel Single Phase Two Conductors per Phase Three Phase or or Three Conductors per Phase Not Recoended Four Conductors per Phase or or Page 101

104 General Technical Information Bending Radii The safe bending radius for an electric cable is limited by the flexibility of its insulation and sheathing material. When a cable is being installed it may be pulled around several curves in different directions and subjected to dynamic stresses which could cause damage. Consequently the bending radius around which a cable may be pulled is greater than that into which it can be set in its final position. The following recoended minimum bending radii are expressed as a function of the cable diameter and refer to the inside of the curve. In all cases, bending radii should be as large as practicable. Cable Type (choose the highest value of all relevant construction features) During Installation Factor (F) Installed All Cable Types Nylon Covered MV XLPE Cables LV (0.6/1kV) Cables HDPE Sheath Helical Copper or Brass Taped Steel Wire Armoured Solid Aluminium Conductors 12 8 Compacted or Shaped Stranded Conductors Single Core and Multicore Cables PVC/XLPE Insulation 9 6 R = F x D where: R = Minimum Internal Bending Radius ) D = Cable Diameter () F = Factor from above table Page 102

105 General Technical Information Duct Sizes Ducts are another important consideration affecting the pulling operation. Selection of the appropriate duct should be based on internal duct diameter to suit a cable size and wall thickness to prevent deformation during duct installation. The internal finish of the installed ducting should be smooth to prevent cable sheath damage during installation. During cable installation the use of graphite or other coercially available pulling lubricants can also prevent sheath damage and reduce pulling tensions. The following duct sizes are recoended: Heavy Duty Rigid PVC Conduit Nominal Size () Single Cable () Three Cables () Four Cables () 50 Up to to to 47 Up to 24 Up to to to to to to to to to to to to to Above 142 Above 73 Above 63 Page 103

106 General Technical Information Pulling Tension Where a cable is to be pulled in using a winch and steel wire rope, the rope may be secured to the cable by any of the following: A cable stocking of steel wire braid A pulling eye attached to the cable conductor A pulling eye over the complete cable end A pulling eye formed from the armour wires The maximum tension which may be used is limited by the tensile strength of the conductors or armour wires, or by the gripping capability of the cable stocking, depending on the method used. Material Maximum Safe Tensile Stress (S) kn/² Stranded Copper Conductor 0.07 Stranded Aluminium Conductor 0.05 Solid Aluminium Conductor 0.03 Galvanised Mild Steel Armour 0.13 Aluminium Wire Armour 0.04 Method of Calculation Using values of S from table above: a) Limited by Conductor T c = N * A c * S where: T c = Maximum Pulling Tension (kn) N = No. of Conductors A c = Cross-sectional Area of one Conductor (²) S = Maximum Safe Tensile Stress for Conductor (kn/²) continued Page 104

107 General Technical Information Pulling Tension (continued) b) Limited by Armour T a = 2.47 * d a * (D a + d a ) * S where: T a = Maximum Pulling Tension (kn) S = Maximum Safe Tensile Stress for Armour (kn/²) d a = Nominal Diameter of Armour Wire () D a = Nominal Diameter under Armour (). c) Limited by Stocking T s = * D where: T s = Maximum Pulling Tension (kn) D = Overall Diameter of the Cable () Overall Limiting Tension Cable OD () Maximum Pulling Tension (kn) 0 to to to and over 20 The safe pulling tension is the smallest of the calculated values. Page 105

108 General Technical Information Copper Conductor Dimensions Nominal Cross Sec. Area ² Note Circular Nominal Diameter Compacted Minimum Diameter Three Core, 120 Sectored Nominal Max Depth Width Four Core, 90 Sectored Nominal Max Depth Width Lugs and links must always be selected to match the nominal cross sectional area of the conductor. A lug or link for a circular conductor may fit on a compacted conductor but may not be rated to carry the load current associated with the larger conductor size; nor will it compress correctly if it is of the compression type. Page 106

109 General Technical Information Aluminium Conductor Dimensions Nominal Cross Sec. Area ² Note Circular Nominal Diameter Compacted Minimum Diameter Three Core, 120 Sectored Nominal Max Depth Width Four Core, 90 Sectored Nominal Max Depth Width Lugs and links must always be selected to match the nominal cross sectional area of the conductor. A lug or link for a circular conductor may fit on a compacted conductor but may not be rated to carry the load current associated with the larger conductor size; nor will it compress correctly if it is of the compression type. Page 107

110 Cable Selection Four Main Factors In accordance with AS/NZS and AS/NZS 3000, the four main factors which affect the minimum size of cable required for a particular installation are: 1. The cable current-carrying capacity, which is influenced by the cable materials and construction, the conditions of the cable environment and the method of installation due to their effects on the dissipation of heat from the conductors. 2. The voltage drop in the cable circuit, which is a function of load current, load power factor, and length of the cable run. 3. The temperature rise under short-circuit conditions, which is a function of both the magnitude and duration of the short-circuit current and is limited by the cable materials. 4. The maximum fault loop impedance which will still allow the protective device to trip within the specified time. Page 108

111 Cable Selection Procedures To select the cable size required based on the above considerations, follow the steps listed: Current-Carrying Capacity 1 Determine the minimum current for which the cable is to be rated, taking account of the maximum demand of the circuit and the type and rating of the overcurrent protection device. 2 Ascertain how the cables are to be installed, and the conditions in the cable environment. From the tables of rating factors, select any rating factor(s) which are applicable. 3 Divide the rating from step 1 by the appropriate factor(s). 4 From the current rating tables, select a cable which, for the appropriate method of installation, has a tabulated rating not less than the value obtained from 3. Voltage Drop 1 Determine the Load Current I (A) to be carried by the cable, and the Route Length L (m) of the circuit. 2 Establish the maximum voltage drop V d (V) permitted in the circuit (taking account of any other voltage drops in series). 3 Evaluate the equation Vc = 1000 * Vd ( mv/a.m). This value is the maximum mv/a.m I * L figure which will give the required voltage drop. 4 From the voltage drop tables, select a cable for the appropriate method of installation which has a tabulated mv/a.m figure not greater than this value. continued Page 109

112 Cable Selection Procedures (continued) Short Circuit Temperature 1 Determine the Maximum Duration t (s) and Magnitude I sc (A) of the prospective Short Circuit Current. 2 Evaluate the equation I 1 = I sc * t (A). This is the required short circuit rating converted to a one second basis. 3 From the conductor short-circuit ratings tables, select a cable with a rating not less than the value obtained from 2. Fault Loop Impedance 1 Determine the maximum fault loop impedance which will still allow the protective device to trip within the specified time. 2 From the above calculate the maximum length of cable run to comply with the maximum fault loop impedance. Refer to AS/NZS 3000:2007, Clause and Appendix B. General For any circuit, the cable size selected should not be less than the largest of the sizes calculated to meet the above limitations (this is the smallest size which will meet all of the requirements). In practice, the current-carrying capacity will be found to prevail in short-run/high-current circuits while voltage drop considerations will usually prevail in long-run/low-current circuits. It is unusual for short-circuit temperature requirements to determine the conductor size required for 0.6/1 kv cable circuits. Page 110

113 Cable Selection Current Ratings The current carrying capacity of a cable is determined by the following factors: 1. Current flowing in a conductor generates heat and causes the conductor temperature to rise above the ambient temperature. 2. Different methods of installation or the presence of external heat sources such as adjacent cables vary the rate of heat dissipation. 3. The insulation material determines the maximum conductor temperature which can be sustained continuously over the expected life of the cable. The continuous current ratings for Low Voltage (LV) 0.6/1 kv cables given in this handbook have been obtained from AS/NZS In all cases, the ratings given are the single circuit ratings, corresponding to continuous loading at the maximum conductor temperature appropriate to the insulation material. Environmental Conditions The current ratings are based on the following operational conditions: Ambient Air Temperature 30ºC Soil Temperature 15ºC Soil Thermal Resistivity 1.2 K.m/W Depth of Burial 0.5 m Where conditions vary from those on which the ratings are based, appropriate rating factors from Tables 3 to 6 (page 116), need to be applied. Methods of Installation Earthing conductors and lightly loaded neutral conductors of three phase circuits are ignored for current rating purposes and are generally not shown in the graphical representations of the cable and installation methods. Thus, where two single core cables or a two core cable is shown the current rating applies to single phase operation; where three single core cables or a three core cable is shown the current rating applies to two or three phase operation. continued Page 111

114 Cable Selection Current Ratings (continued) Groups of Circuits For groups of circuits unenclosed in air, the spacings and arrangements which need to be maintained to prevent derating are given on Tables 1A & 1B (page 99 & 100). Where underground circuits are spaced by more than 2m from adjacent circuits, no derating applies. Also, if adjacent circuits are operated at less than 35% of their current carrying capacity they may be excluded from considerations as their contribution to mutual heating will be small. Where a number of circuits are installed in close proximity in such a way that they are not thermally independent, the appropriate rating factors from Tables 7 and 8 (page 117) need to be applied. Cables in Parallel For cables operated in parallel, each parallel leg is regarded as a separated circuit for current rating purposes and the appropriate rating factors for grouping are applicable. Refer also to Table 2 (page 101) for the arrangements of single core cables so as to ensure equal current sharing between parallel legs of the same phase. Solar Radiation For cables exposes to direct sunlight, the effect of solar radiation is to increase the surface temperature of the cable and hence limit the temperature rise due to the load in the conductors. Where possible, cables should be shielded from the direct rays of the sun without restricting ventilation. Otherwise, the effect of solar radiation should be taken into account, either by calculation in accordance with IEC 60287, or as an approximation by adding 20ºC to the ambient air temperature and applying the appropriate rating factor. Page 112

115 Cable Selection Simple Cable Selection Chart The tables below and on the next page are based on data obtained from AS/NZS and assume the following conditions: Single core, XLPE insulated cables, installed in flat configuration, directly buried in ground; 1-phase 230 V supply, or 3-phase 400 V supply, as applicable; Maximum volt drop limited to 2.5% of supply voltage. For longer runs, different cable configurations or other more specific conditions, please contact our nearest Olex NZ representative. Cable Size ² 30 amps per phase Maximum Run length (meters) Aluminium Copper 1-Phase 3-Phase 1-Phase 3-Phase 16 n/a n/a n/a n/a continued Page 113

116 Cable Selection Simple Cable Selection Chart (continued) 63 amps per phase Maximum Run length (meters) Cable Size Aluminium Copper ² 1-Phase 3-Phase 1-Phase 3-Phase 16 n/a n/a n/a n/a Cable Size ² continued 100 amps per phase Maximum Run length (meters) Aluminium 1-Phase 3-Phase Copper 1-Phase 3-Phase 25 n/a n/a Page 114

117 Cable Selection Simple Cable Selection Chart (continued) Cable Size ² 150 amps per phase Maximum Run length (meters) Aluminium 1-Phase 3-Phase Copper 1-Phase 3-Phase Cable Size ² 200 amps per phase Maximum Run length (meters) Aluminium 1-Phase 3-Phase Copper 1-Phase 3-Phase Page 115

118 Cable Selection Low Voltage (0.6/1 kv) Rating Factors Table 3 - Ambient Air Temperature Variation Insulation Air Temperature ( C) Type PVC XLPE Table 4 - Soil Temperature Variation Insulation Soil Temperature ( C) Type PVC XLPE Table 5 - Depth of Burial Variation Laid Direct In Underground Ducts Depth of Burial Up to Above 50² Above Single Multicore 50² Up to 300² 300² Core (or deeper) Table 6 - Soil Thermal Resistivity Variation Soil Thermal Resistivity (K.m/W) continued Page 116

119 Cable Selection Low Voltage (0.6/1 kv) Rating Factors (continued) Table 7 - Groups of Circuits Laid Direct in Ground Single Core Cables Multicore Cables No. of Circuits spacing spacing spacing Touching Spacing (m) Spacing (m) Trefoil Flat Touching Table 8 - Groups of Circuits In Underground Ducts Single Core Cables in Single-way Single Core Cables in Multiway Ducts or Ducts Multicore Cables in Single-way Ducts No. of Circuits spacing spacing spacing Touching Spacing (m) Spacing (m) Touching Page 117

120 Current Ratings Single Conductor PVC (Single Phase) PVC insulation Unarmoured Sheathed or unsheathed For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Single core TPS Vintol Page 118

121 Current Ratings Single Conductor XLPE (Single Phase) XLPE insulation Unarmoured Sheathed or unsheathed For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Cantol Page 119

122 Current Ratings Two Conductor PVC (Single Phase) PVC insulation Armoured or unarmoured For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range TPS Remolex PVC Armoured Mains PVC Neutral Screen Page 120

123 Current Ratings Two Conductor XLPE (Single Phase) XLPE insulation Armoured or unarmoured For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Cempex XLPE Armoured Mains XLPE Neutral Screen Page 121

124 Current Ratings Single Conductor PVC (Three Phase) PVC insulation Unarmoured Sheathed or unsheathed For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Three Phase Voltage Drop mv/a.m Trefoil Flat Three Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Single core TPS Vintol Page 122

125 Current Ratings Single Conductor XLPE (Three Phase) XLPE insulation Unarmoured Sheathed or unsheathed For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Three Phase Voltage Drop mv/a.m Trefoil Flat Three Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Cantol Page 123

126 Current Ratings Single Conductor Ceramifiable (Three Phase) Copper conductor R-E-110/HFS-110-TP 110ºC For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Three Phase Voltage Drop mv/a.m Trefoil Flat Three Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Alsecure Premium Ceramifiable Single Core Page 124

127 Current Ratings Three & Four Conductor PVC (Three Phase) PVC insulation Armoured or unarmoured For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Three Phase Voltage Drop mv/a.m Three Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Remolex PVC Armoured Mains PVC Neutral Screen Page 125

128 Current Ratings Three & Four Conductor XLPE (Three Phase) XLPE insulation Armoured or unarmoured For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Unenclosed Spaced from Touching Surface Enclosed Conduit in Air Buried Direct Underground Ducts Three Phase Voltage Drop mv/a.m Three Phase Cu Al Cu Al Cu Al Cu Al Cu Al Cu Al The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Example Product Range Cempex XLPE Armoured Mains XLPE Neutral Screen Aluminium URD Cables Page 126

129 Current Ratings PVC Flexible Cords Copper conductors PVC insulation and sheath Max DC Resist. Voltage Drop Conductor 20ºC Ohm/km mv/a.m Size Rating ² amps Single Three PACW TACW Phase Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 25 C Page 127

130 Current Ratings Versolex Single Core Flexible Cables (Single Phase) Installed as fixed wiring Flexible copper conductor Flexible XLPE insulation For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Spaced from Surface Unenclosed Touching Exposed to Sun Enclosed Conduit in Air Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Page 128

131 Current Ratings Versolex Single Core Flexible Cables (Three Phase) Installed as fixed wiring Flexible copper conductor Flexible XLPE insulation For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Spaced from Surface Unenclosed Touching Exposed to Sun Enclosed Conduit in Air Underground Ducts Three Phase Voltage Drop mv/a.m Trefoil Flat Three Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Page 129

132 Current Ratings Versolex Two Core Flexible Cables (Single Phase) Installed as fixed wiring Flexible copper conductor Flexible XLPE insulation For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Spaced from Surface Unenclosed Touching Exposed to Sun Enclosed Conduit in Air Underground Ducts Single Phase Voltage Drop mv/a.m Single Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Page 130

133 Current Ratings Versolex Three & Four Core Flexible Cables (Three Phase) Installed as fixed wiring Flexible copper conductor Flexible XLPE insulation For cables up to and including 0.6/1 50 Hz AC. Conductor Size 2 Spaced from Surface Unenclosed Touching Exposed to Sun Enclosed Conduit in Air Underground Ducts Three Phase Voltage Drop mv/a.m Three Phase The values in this table have been obtained from AS/NZS for typical New Zealand installation conditions: Ambient Air Temperature: 30 C Soil Temperature: 15 C Soil Thermal Resistivity: 1.2 K.m/W Depth of Burial: 0.5 m Page 131

134 Current Ratings AAC Aerial Conductors Aluminium conductor Bare and PVC covered Name Area ² Calculated DC 20ºC Ohm/km Reactance at 50Hz with 300 Spacing Ohm/km Still Air (amps) Current Rating 1.0 m/s wind (amps) Bare Namu Poko Ladybird Kutu Fly Rango Grasshopper Wasp Beetle Weke Bee Cricket Weta Mata Cockroach Butterfly Cicada Covered Namu Ladybird Kutu Fly Rango Wasp Beetle Weke Weta Note 1 Coefficient of linear expansion 23.0 x 10-6 /ºC. 2 Modulus of elasticity 65 GPa except for Cicada which is 64 GPa. 3 Current ratings are based on an ambient temperature of 30ºC, a maximum conductor temperature of 75ºC, rural weathered, suer noon and intensity of solar radiation 1000 W/m². Page 132

135 Current Ratings AAAC Aerial Conductors 1120 Aluminium alloy conductor Name Area ² Calculated DC 20ºC Ohm/km Reactance at 50Hz with 300 Spacing Ohm/km Current Rating Still Air (amps) 1.0 m/s wind (amps) Bare Chlorine Fluorine Helium Hydrogen Iodine Krypton Neon Nitrogen Note 1 Coefficient of linear expansion 23.0 x 10-6 /ºC. 2 Modulus of elasticity 65 GPa except for Nitrogen which is 64 GPa. 3 Current ratings are based on an ambient temperature of 30ºC, a maximum conductor temperature of 75ºC, rural weathered, suer noon and intensity of solar radiation 1000 W/m². Page 133

136 Current Ratings ACSR Aerial Conductors Aluminium conductor Galvanised steel reinforced Name Equ Alu. Area ² Calculated DC 20ºC Ohm/km Reactance at 50Hz with 300 Spacing Ohm/km Current Rating Still Air (amps) 1.0 m/s wind (amps) Bare Magpie Squirrel Gopher Ferret Mink Raccoon Dog Dingo Wolf Jaguar Goat Note Current ratings are based on an ambient temperature of 30ºC, a maximum conductor temperature of 75ºC, rural weathered, suer noon and intensity of solar radiation 1000 W/m². Page 134

137 Current Ratings Al Aerial Bundled Cables (ABC) Aluminium conductor XLPE insulated Area ² Calculated DC 20ºC Ohm/km Max AC 80ºC Ohm/km Positive Sequence Reactance at 50Hz Ohm/km Current Rating amps Two Core Three Core Four Core Note 1 Coefficient of linear expansion 23.0 x 10-6 /ºC. 2 Modulus of elasticity 59 GPa up to and including 50 ² and 56 GPa for conductors above 50 ². 3 Current ratings are based on an ambient temperature of 30ºC, a maximum conductor temperature of 80ºC, wind speed of 1 m/s and intensity of solar radiation 1000 W/m². Page 135

138 Current Ratings Cu Aerial Hard Drawn Hard Drawn copper conductor Bare and PVC covered Area ² Calculated DC 20ºC Ohm/km Reactance at 50Hz with 300 Spacing Ohm/km Still Air (amps) Current Rating 1.0 m/s wind (amps) Bare Made to AS 1746: Covered Made to AS/NZS Note 1 Coefficient of linear expansion 17.0 x 10-6 /ºC. 2 Modulus of elasticity for bare conductors: 119 GPa for 6, 10, 16 & 25 ² 118 GPa for 35, 50 & 70 ² 117 GPa for 95 ² Modulus of elasticity for covered conductors: 112 GPa for 6, 10 & 16 ² 110 GPa for 25, 35, 50 & 70 ² 108 GPa for 95 ² 3 Current ratings are based on an ambient temperature of 30ºC, a maximum conductor temperature of 75ºC, rural weathered, suer noon and intensity of solar radiation 1000 W/m². Page 136

139 General Data Useful 3 Phase Formulae kw = kva x pf kw = kw = kva = kva = kva = Line Amps = Line Amps = Line Amps = hp * * Eff Line Amps * Line Volts * * pf 1000 kw pf hp * 746 a 1000 * Eff * pf Lines Amps * Line Volts * kw * 1000 a Line Volts * x pf kva * 1000 a Line Volts * hp *746 a Line Volts * * Eff * pf Horsepower (hp) = kw * 1000 * Eff 746 hp = hp = kva * 1000 * Eff * pf 746 Line Amps * Line Volts * * Eff * pf 746 Page 137

140 General Data Wire & Cable Size Comparison AWG kcmil ² inch² / / / / Page 138

141 General Data Motor Current Table (Amperes approx) Power kw hp Single Phase 230V Three Phase 400V Single Phase 240V Three Phase 415V Page 139

142 General Data Abbreviations Abv. Description Abv. Description A.m. Ampere metre kv Kilovolt AC Alternating current kva Kilovoltamp Al Aluminium kw Kilowatt AS Australian Standard L.D. Light Duty AS/NZS Australian and New Zealand Standard Millimetre C Core nf/km Nanofarad/kilometre ºC Degrees Celsius NZS New Zealand Standard CPE Chlorinated Polyethylene OD Outside diameter CSA Cross-sectional Area O.D. Ordinary Duty CSP Chlorosulphinated Polyethylene PACW plain annaled copper wire Cu Copper PE Polyethylene db Decibel pf Power factor DC Direct Current pf/m Picofarad/metre E Earth PILC Paper insulated lead covered EA Ethylene Acrylic PVC Polyvinyl Chloride Eff Efficiency R-CPE- Rubber Chlorinated 90 Polyethylene - 90ºC ELV Extra Low Voltage R-EP-90 Rubber Ethylene Propylene - 90ºC EPR Ethylene Propylene Rubber - Halogen Free R-HF-110 Rubber 110ºC HD Hard Drawn SWA Steel Wire Armoured H.D. Heavy Duty TACW Tinned Annealed Cooper Wire HFS-90-TP Halogen Free Sheath 90ºC Thermoplastic TPW Thermoplastic welding HF-110-R Halogen Free 110ºC Rubber UTP Unshielded twisted pair hp Horse power V Volt HR Heat Resistant V75 75ºC rated PVC HRC High Rupture Capacity V90 90ºC rated PVC (for restricted periods) ISDN Integrated Services Digital 90ºC rated PVC 105ºC V90HT Network (for restricted periods) kg Kilogram X-HF-90 XLPE halogen free - 90ºC kn Kilonewton XLPE Cross linked Polyethylene Page 140

143 General Data Copper Earthing Conductors Minimum size of Copper earthing conductors. Nominal area active conductors ² For Copper active conductors ² For Aluminium active conductors ² * * * Refer Wiring Rules AS/NZS 3000 regarding 1.0 and 1.5 earthing conductors. Page 141

144 The Olex Range Low Voltage Power and Control Cables Building Wires Flats PVC/PVC SDIs XLPE/PVC Single Cores PVC/PVC Circulars XLPE/PVC Multicores Armoured PVC/PVC Circulars Armoured XLPE/PVC Multicores Multicore Control Armoured Multicore Control Neutral Screened Aerial Varolex Screened VSD/EMC Fire Performance Cables Alsecure Premium Ceramifiable Fire Rated (FR) - single core ES110 - multicore ES90 - flex - FRP Fire Safe (FS) Power Rolling Stock Locomotive Alsecure Envirolex Instrolex Instrumentation Cables Overall screened Overall screened armoured Individual & overall screened Individual & overall screened armoured Thermocouple extension wire Flexible Power & Control Cables Versolex - XLPE/TPE - Power - Welding - EMC/VSD - Submersible Flexolex EPR/CPE Power Titanex PVC/PVC Power PVC/PVC Control Data & Counications Cables Datolex - Security - Figure 8 - Category 5E LAN - Category 6 LAN - Coaxial Gardolex Garden Lighting Audiolex - Speaker - Coaxial Fibre - Multi Mode - Single Mode Telephone - Internal - External Data Page 142

145 The Olex Range Mining Cables (flexible) to 33kV Reeling and Trailing Cables to AS/NZS 1802 and 2802 Feeder Cables Machine Cables Specialised Industrial Cables Airport Lighting Cables - Primary & Secondary cables Automation Cables Offshore Oil & Gas Cables Defence Cables - AO 14,000 - VG cables - Milspec cables Rolling Stock Cables Materials Handling Cables Marine Cables Wind Turbine Cables HV Transmission Cables Extra High Voltage U/G XLPE to 330kV (joints, terminations, engineering services, condition monitoring) Bare Overhead Conductors All Aluminium All Aluminium Alloy 1120 ACSR Steel Earth Wire and Stay Wire (galvanised or aluminium clad) HV Distribution Cables U/G XLPE to 33kV Paper Insulated Lead Covered to 33kV Aerial Bundled Cable XLPE to 33kV (metallic and non-metallic screened) Covered Conductor Single Point Suspension HV Submarine Cables 11kV to 33kV (EHV also) XLPE, EPR or PILC Insulation Radial Water Barrier - Al/HDPE, LAS, Stainless Steel Sheath Mechanical Protection - Single, Double Wire Armour, HDPE, - Hessian-Served Page 143

146 Olex Branch Locations Head Office Paraite Road Bell Block New Plymouth 4373 Private Bag 2021 New Plymouth 4342 Phone Facsimile Auckland 105 Hugo Johnson Drive Penrose Auckland 1061 P O Box Onehunga Auckland 1643 Phone Facsimile Christchurch 35 Phillips Street Phillipstown Christchurch 8011 P O Box Linwood Christchurch 8642 Phone Facsimile Page 144

147 Notes Page 145

148 Head Office Paraite Road, Bell Block, New Plymouth 4373 New Zealand Phone Fax Cable Sales Tel 0800 OLEX NZ ( ) For more information see

Notes 3 Explanatory Information 4-10

Notes 3 Explanatory Information 4-10 Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

P Low Voltage Catalogue Cables Australia Powering your Project

P Low Voltage Catalogue Cables Australia Powering your Project P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV

EXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated

More information

ABOUT US ABOUT US 1 CRANE CABLES

ABOUT US ABOUT US 1 CRANE CABLES ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor

HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY Exclusive Authorised UK Distributor Technical Data Trademark Type designation Specification Application HYDROFIRM(T)

More information

Railway products. Edition 2014

Railway products. Edition 2014 Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components

More information

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)

More information

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12 Mining Cables Contents Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12 Type 241 and 241SF 14 Type 245SF 16 Type

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

Flexitime! Our flexible cables save you time and money.

Flexitime! Our flexible cables save you time and money. Flexitime! Our flexible cables save you time and money. We re flexible so you won t have to be. With our improved range of flexible cables we ve brought flexibility to a completely new level. From now

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured) WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation

More information

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

TRAXLINE CABLES FOR MOTION

TRAXLINE CABLES FOR MOTION TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables

More information

Electric cables. Cranes

Electric cables. Cranes Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

Marine Cables General Catalogue

Marine Cables General Catalogue Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes

More information

MarineLine YOZp 0,6/1 kv

MarineLine YOZp 0,6/1 kv Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame

More information

Technical cable guide

Technical cable guide Technical cable guide June 2015 One stop-shop for all your cable needs New Zealand edition DISCLAIMER Cables must be installed according to the requirements of AS/NZS 3000, the Wiring Rules and any supplementary

More information

FieldLink MC at 20 x outer diameter Torsion

FieldLink MC at 20 x outer diameter Torsion Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation

More information

FLEXIBLE MULTI CORE CABLES

FLEXIBLE MULTI CORE CABLES FLEXIBLE MULTI FTM Series...22 MTSV Series...23 TW-T Series...24 PF Series...25 OD Series... 27 HD Series...28 MLG2 Multi Series...30 HO Plus Series...32 HR Series... 34 HRP Series...36 FX Series... 37

More information

Power Cables and their Application

Power Cables and their Application Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

High Temperature Flexible Control Cable

High Temperature Flexible Control Cable High Temperature Flexible Control Cable 0 High Temperature Flexible Control Cable SILFLEX UL/CSA UL/CSA/CE 0 High Temperature Silicone Control Cable with UL/CSA SILFLEX SiHF CE 0 High Temperature Silicone

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

kv: medium voltage reeling cable with fibreoptics

kv: medium voltage reeling cable with fibreoptics PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy

More information

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging

More information

CABLES AND WIRES

CABLES AND WIRES CABLES AND WIRES VOLTEX CATALOGUE 41 3 PVC GENERAL PURPOSE WIRE 1kV House Wire 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC

More information

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations

NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations Version: 3.1 Date of Issue: September 2016 Page: 1 of 21 NPS/002/016 Technical Specification for 33 kv Cable Joints and Terminations 1. Purpose The purpose of this document is to detail the technical requirements

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

WIRE & CABLE. 99 Wire Low fire hazard wire and cable Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :

Cables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By : Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg

More information

BENDING RADIUS. DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance CORE IDENTIFICATION TECHNICAL INFORMATION 8/2010

BENDING RADIUS. DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance CORE IDENTIFICATION TECHNICAL INFORMATION 8/2010 BENDING RADIUS Recommended minimum bending radius, ( R ) : Radius (R) Outer diameter (D) LKM-HF During installation R = 6x D < mm LKMM-HF During installation R = 6x D < mm LKM-FRHF During installation

More information

Armoured Instrumentation Cables to BS6883

Armoured Instrumentation Cables to BS6883 Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring

More information

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT

TPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type

More information

Welding Cables Rubber Insulated

Welding Cables Rubber Insulated Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications

More information

HOOK-UP WIRE A STYLE TO SUIT ANY NEED

HOOK-UP WIRE A STYLE TO SUIT ANY NEED A STYLE TO SUIT ANY NEED Alpha s commitment to quality and service starts at the beginning... with the manufacturing of single conductor hook-up wire, the most basic wiring component. Used extensively

More information

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable.   Features & Benefits Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a

More information

Installation Recommendations

Installation Recommendations Installation Recommendations Cable pulling recommendations The process of pulling electrical cables on board marine vessels is a relatively standard procedure. Nevertheless, NEXANS would suggest the following

More information

15 years of experience

15 years of experience Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since

More information

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID

SY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID ISSUE DATE: 05/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11:2011 Plain Annealed Flexible Copper Conductors / PVC Insulated / PVC Bedding / GSWB (Galvanised Steel Wire Braid) / PVC Sheathed.

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED

CY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned

More information

How to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)

How to order. Payment options. Delivery options. Online   acatalog. By phone + (44) By fax + (44) S P E C I A L I S T C A B L E S U P P L I E R S How to order Online / acatalog By phone + (44) 1628 850024 By fax + (44) 1628 648068 By email info@csecables.com Our hours Monday to Friday, 8am-5.30pm Payment

More information

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability

Innovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability Introduction Innovative Eldra Solar Cabling System Eldra is an innovative company of international standing. A fast growing, ambitious business offering a broad range of high quality products and with

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813

RHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813 with / without optical fibre elements 3.6/6 kv Contents: Letter code Construction details and voltage-classes Technical data 1 with / without optical fibre elements Letter code Flexible cables acc. to

More information

MULTIMEDIA & DATA TRANSMISSION

MULTIMEDIA & DATA TRANSMISSION NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling

More information

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water

HYDROFIRM (T) Cables. for use in Ground Water and Drinking Water HYDROFIRM (T) Cables for use in Ground Water and Drinking Water Finely stranded copper conductor EPR insulation Special synthetic rubber sheath Until now, the renowned HYDROFIRM TGK cables were available

More information

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Low Voltage AIRGUARD. A proven, rugged product for harsh environments Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

Chapter 6. WIRING SYSTEMS Safe Electrical Design

Chapter 6. WIRING SYSTEMS Safe Electrical Design Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

Technical Specification. for 1.1 KV Copper Control Cable

Technical Specification. for 1.1 KV Copper Control Cable WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD INTERNATIONAL STANDARD IEC 61156-1 Third edition 2007-06 Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification Commission Electrotechnique Internationale International

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

Table of contents. Phone: Fax:

Table of contents. Phone: Fax: HELUKABEL GmbH Dieselstrasse 7 Hemmingen GERMANY Tel. +9 (0)750 9090 Fax.+9.(0)750.7 www.helukabel.de info@helukabel.de Created at 03/3/0 by Phone: Fax: EMail: Table of contents Page : Page 5 from. CABLES,

More information

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017

MEDIUM VOLTAGE TERMINATIONS CATALOGUE 2017 MEDIUM VOLTAGE TERMINATIONS CATALOGUE 01 NEXANS NETWORK SOLUTIONS DIV. EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

TYGADURE FOR EXTREME APPLICATIONS

TYGADURE FOR EXTREME APPLICATIONS TYGADURE FOR EXTREME APPLICATIONS CONTENTS ABOUT US 2 TYGADURE 3 PTFE (Polytetrafluoroethylene) 4 FEP (Flourinated Ethylene Propylene) 5 SILICONE RUBBER 6 TYGASIL CLASS H 7 ETFE (Ethylene Tetraflouroethylene)

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

EDS LV WAVEFORM MAINS CABLE RATINGS

EDS LV WAVEFORM MAINS CABLE RATINGS Document Number: EDS 02-0033 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 02-0033 LV WAVEFORM MAINS CABLE RATINGS EPN, LPN, SPN This standard details the technical and practical information required

More information

SUBMERSIBLE PUMP CABLES

SUBMERSIBLE PUMP CABLES 12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum

More information

Product information. Marine, Oil & Gas.

Product information. Marine, Oil & Gas. Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded

More information

a Nexans company Catalogue 2009

a Nexans company Catalogue 2009 a Nexans company Catalogue 009 EUROMOLD COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable accessories for medium voltage

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE LIFT & CRANE CABLE Reference Quick Select Chart 132 Crane Cable Installation Instructions 133 Lift Cable Installation Instructions 134 ÖLFLEX ÖLFLEX CRANE NSHTÖU 135 Reelable Cable for Low to Medium Mechanical

More information

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc. ()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical

More information

a Nexans company Catalogue 2012

a Nexans company Catalogue 2012 a Nexans company Catalogue 0 Nexans Network Solutions Div. Euromold COMPANY PRESENTATION EUROMOLD Euromold is the leading European specialised designer, manufacturer and distributor of prefabricated cable

More information

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable 05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD(RTS)

More information

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C

EXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C Page 1 of 24 ETRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C ESCC Detail Specification Issue 4 March 2013 Document

More information

Paramount Communications Ltd., part of the Paramount Cables Group. started up as a small- scale cable unit more than 60 years ago and

Paramount Communications Ltd., part of the Paramount Cables Group. started up as a small- scale cable unit more than 60 years ago and INDUSTRIAL CABLES Paramount Communications Ltd., part of the Paramount Cables Group started up as a small- scale cable unit more than 60 years ago and became one of the nation s leading cables manufacturing

More information

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT:

SLEEVING (CONVOLUTED) SLEEVING (SPLIT CONVOLUTED) SLEEVING (PVC) 56 AUTO MARINE PRODUCT CATALOGUE 2018/19 VISIT: SLEEVING (CONVOLUTED) Halogen-free nylon convoluted sleeving suitable for bundling of wires and protection against abrasion. Continuous operating temperature -40ºC to 5ºC with short excursions up to 150ºC.

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD

More information

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of

More information

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES

MGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested

More information

Servo Cable Selection

Servo Cable Selection Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)

More information

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc 10 South Ridge Dr Charlotte, NC 282 Phone 0-0-0222 Fax 0-0-022 Toll free 1-800--21 www.lutze.com info@lutze.com Lutze Flexible Control

More information

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)

TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +

More information