SUPERIOR MARINE CABLE SOLUTIONS
|
|
- Dwayne Burke
- 6 years ago
- Views:
Transcription
1 SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED
2 Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables and electrical components to the marine industry. With headquarters located in Taiwan and service branches in China and Canada, our sterling reputation has permeated throughout Asia. In addition to offering products of the highest quality, safety is paramount to us. All of our cables conform to major international standards; including IEC & IEEE, which carry approval from ABS, BV, DNV, GL. LR, USCG, and TC NAVSEA. Our cables are used globally within specialized markets: including, the Marine, Auto and Industrial industries. More specifically, these include Navy and Defense, Mega Yachts, Fast Ferries, Offshore Rigs and Platforms, Switchboard/Control Panels, Fire Protection and Submersible Pumps. In addition to our wide selection of cables, we also offer premium electrical accessories. These comply and meet the ABYC standard and USCG regulations guaranteeing the safety of the products. What makes us unique is that in addition to providing the highest quality products, we offer a professional working team to provide knowledge, service, and engineering as added value to our customers. Our company mission is to provide professionalism, customer satisfaction, and innovation. Pursuing quality, safety, and stability in all of our products is central to our mission. Additionally, we strive to continue to serve and to demonstrate our commitment to build meaningful and reliable relationships with all of our business associates.
3 Table of Content Table of Content 4 LSZH Shipboard Cable 5 Difference between LSZH & non LSZH cables AWG mm / / / / McM mm Coastal Craft 300 Open Switchboard Wire 6 UP series Power and Control 7-9 BV series DV series Instrumentation RC series RS series EW series EG series RR series BH series ES series FJ series 28 DF series Fire Resistant Power and Control Variable Frequency Drive UL 1426 Boat Cable BC 5W Primary Wire (16 AWG ~ 10 AWG) 31 Marine Battery Cable (8 AWG ~ 4/0 AWG) 32 Duplex Flat 32 Triplex Flat Marine Quality Electrical Accessories Terminal & Connector Heavy Duty Lugs/Power Distribution Post/ Fuse Holder/Insulator Wire/Cable Management 3
4 LSZH Shipboard Cable LSZH simply translates to Low Smoke Zero Halogen and refers to the behavior of chemical compounds when combusted specifically the quantity of smoke generated and the toxicity of the emissions. Halogens What are they? > Halogens are a group of five elements comprising; Fluorine, Chlorine, Bromine, Iodine and Astatine. Halogens The effect of combustion? > In their basic form, Halogens are very toxic, strong oxidizers and very chemically reactive. In the event of combustion, LSZH and non LSZH cables behave in very different ways, as indicated below. Vertex LSZH Cables Non LSZH Cables No Halogens Low Smoke Halogen Emissions Dense Smoke 4 No Acids Corrosive Acids
5 What is the difference between LSZH and non LSZH cables? LSZH cables have a zero halogen content, emit no toxic fumes, generate very little smoke and produce no corrosive or caustic acids. LSZH cables are therefore ideally suited for all marine applications where personnel safety and protection of valuable equipment are of paramount importance. Non LSZH cables, or Halogenated Cables, are typically manufactured from thermoplastic compounds, such as PVC. On combustion, these compounds generate highly toxic fumes that cause severe irritation to the eyes, nose, mouth, throat and lungs. Increased concentrations are considered fatal to humans. They also generate large volumes of dense black smoke that blocks visibility and severely disrupts evacuation procedures. The smoke and fumes can also lead to suffocation from smoke inhalation. A one meter length of burning cable that contains 0.85kg of PVC will completely obscure a room of 100m 3 with black toxic smoke in less than five minutes. When combusted, Halogens combine with moisture to form Hydrochloric Acid. This extremely corrosive acid is potentially deadly to humans and always causes extensive property damage. Acid of this nature aggressively attack electrical switchboards, motors, fixtures, furnishings, floor coverings, paint surfaces etc. In many cases the effects of acid corrosion after a fire are much more severe than the actual fire damage itself. Vertex LSFLEX Insulation & Jacket Materials: > Are halogen free > Emit low smoke > Do not form corrosive acids > Have an extremely low fuel element 5
6 Flexible Shipboard Switchboard/Panel Wire UP series APPLICATION Flexible shipboard cable suitable for all shipboard and marine applications CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water, ozone and UV Color To customer specification OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS LR, DNV, ABS, BV, USCG Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil mm 2 Min Max (inches) (amps) IEEE (amps) IEC (kg/km) 6 1c 16 AWG 1C c 14 AWG 1C c 12 AWG 1C c 10 AWG 1C c 8 AWG 1C c 6 AWG 1C c 4 AWG 1C c 2 AWG 1C c 1 AWG 1C c 2/0 AWG 1C c 3/0 AWG 1C c 236McM 1C c 296 McM 1C c 365 McM 1C c 473 McM 1C c 592 McM 1C c 789 McM 1C
7 Flexible Shipboard Power & Control BV series APPLICATION Flexible shipboard cable suitable for all shipboard and marine applications CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen Assembly Conductors cabled with filler as required and overall binder tape or Aluminum/Polyester Shield + drain wire Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke Zero halogen (TPO/TPPO to IEEE-1580, SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS LR, DNV, ABS, BV, USCG Number of Number of Overall Diameter Minimum Max Approx Conductors x Conductors x (inches) Bending Radius Current Weight AWG/kcmil Cross Section Min Max (inches) (amps) IEEE (kg/km) Area (mm2) 1c 10 AWG 1C c 8 AWG 1C c 6 AWG 1C c 4 AWG 1C c 2 AWG 1C c 1 AWG 1C c 2/0 AWG 1C c 3/0 AWG 1C c 236McM 1C c 296 McM 1C c 365 McM 1C c 473 McM 1C c 592 McM 1C c 789 McM 1C c 986 McM 1c c 1243 McM 1c
8 Flexible Shipboard Power & Control BV series Number of Number of Overall Diameter Minimum Max Approx Conductors x Conductors x (inches) Bending Radius Current Weight AWG/kcmil Cross Section Min Max (inches) (amps) IEEE (kg/km) Area (mm2) 2c 16 AWG 2c c 14 AWG 2c c 12 AWG 2c c 10 AWG 2c c 8 AWG 2c c 6 AWG 2c c 4 AWG 2c c 2 AWG 2c c 16 AWG 3c c 14 AWG 3c c 12 AWG 3c c 10 AWG 3c c 8 AWG 3c c 6 AWG 3c c 4 AWG 3c c 2 AWG 3c c 1 AWG 3c c 2/0 AWG 3c c 3/0 AWG 3c c 236 McM 3c c 296 McM 3c c 365 McM 3c c 473 McM 3c c 592 McM 3c c 16 AWG 4c c 14 AWG 4c c 12 AWG 4c c 10 AWG 4c c 8 AWG 4c c 6 AWG 4c c 4 AWG 4c
9 Flexible Shipboard Power & Control BV series Number of Number of Overall Diameter Minimum Max Approx Conductors x Conductors x (inches) Bending Radius Current Weight AWG/kcmil Cross Section Min Max (inches) (amps) IEEE (kg/km) Area (mm2) 4c 2 AWG 4c c 1 AWG 4c c 2/0 AWG 4c c 3/0 AWG 4c c 236 McM 4c c 296 McM 4c c 365 McM 4c c 16 AWG 5c c 14 AWG 5c c 12 AWG 5c c 10 AWG 5c c 8 AWG 5c c 6 AWG 5c c 4 AWG 5c c 2 AWG 5c c 1 AWG 5c c 16 AWG 7c c 16 AWG 12c c 16 AWG 19c c 16 AWG 24c c 16 AWG 27c c 16 AWG 33c c 16 AWG 37c c 14 AWG 7c c 14 AWG 12c c 14 AWG 19c c 14 AWG 24c c 14 AWG 27c c 14 AWG 33c c 14 AWG 37c
10 Flexible Shipboard Power & Control DV series APPLICATION Flexible shipboard cable suitable for all shipboard and marine applications CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen Assembly Conductors cabled with filler as required and overall binder tape Bedding Tape Polypropylene Braid/Armor Options: Galvanized Steel Wire Braid (90%) Tinned Copper Wire Braid (90%) Overall Tape Polypropylene Jacket: LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke Zero halogen (TPO/TPPO to IEEE-1580, SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze. OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS ABS, BV, DNV, LR, USCG, Transport Canada Marine Safety. Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil Number of Area Min Max (inches) (amps) IEEE (amps) IEC (kg/km) (mm2) 10 1c 10 AWG 1C c 8 AWG 1C c 6 AWG 1C c 4 AWG 1C c 2 AWG 1C c 1 AWG 1C c 2/0 AWG 1C c 3/0 AWG 1C c 236McM 1C c 296 McM 1C c 365 McM 1C c 473 McM 1C c 592 McM 1C c 789 McM 1C c 986 McM 1c c 1243 McM 1c
11 Flexible Shipboard Power & Control DV series Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil Number of Area Min Max (inches) (amps) IEEE (amps) IEC (kg/km) (mm2) 2c 16 AWG 2c c 14 AWG 2c c 12 AWG 2c c 10 AWG 2c c 8 AWG 2c c 6 AWG 2c c 4 AWG 2c c 2 AWG 2c c 16 AWG 3c c 14 AWG 3c c 12 AWG 3c c 10 AWG 3c c 8 AWG 3c c 6 AWG 3c c 4 AWG 3c c 2 AWG 3c c 1 AWG 3c c 2/0 AWG 3c c 3/0 AWG 3c c 236 McM 3c c 296 McM 3c c 365 McM 3c c 473 McM 3c c 592 McM 3c c 16 AWG 4c c 14 AWG 4c c 12 AWG 4c c 10 AWG 4c c 8 AWG 4c c 6 AWG 4c c 4 AWG 4c c 2 AWG 4c c 1 AWG 4c c 2/0 AWG 4c c 3/0 AWG 4c c 236 McM 4c c 296 McM 4c c 365 McM 4c c 16 AWG 5c c 14 AWG 5c c 12 AWG 5c c 10 AWG 5c c 8 AWG 5c c 6 AWG 5c c 4 AWG 5c c 2 AWG 5c c 1 AWG 5c c 16 AWG 7c c 16 AWG 12c c 16 AWG 19c c 16 AWG 24c c 16 AWG 27c c 16 AWG 33c c 16 AWG 37c c 14 AWG 7c c 14 AWG 12c c 14 AWG 19c c 14 AWG 24c c 14 AWG 27c c 14 AWG 33c c 14 AWG 37c
12 Flexible Shipboard Collective Screened Instrumentation RC series APPLICATION Flexible shipboard cable suitable for all marine applications CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen. Splash resistant to oil, skydro, gasoline, acid, sea water. Resists ozone and UV. Isolation Tape Polyester Drain Wire Tinned annealed copper Screen Aluminum/laminate Tape Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke Zero Halogen (TPO/TPPO to IEEE-1580, SHF-1 to IEC ). Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists to ozone and UV OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS LR, DNV, ABS, BV, GL, USCG, Transport Canada Marine Safety (Cold Bend and impact performance test) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 2p 18 (quad) 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p18 24p p18 27p p 18 36p
13 Flexible Shipboard Collective Screened Instrumentation RC series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 (quad) 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p Number of Number of Overall Diameter Minimum Max Approx Triads (t) x Triads (t) (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
14 Flexible Shipboard Collective Screened Braided/Armored Instrumentation RS series APPLICATION Flexible shipboard cable suitable for all marine applications CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Assembly Components cabled with filler as required and overall binder tape Screen Aluminum/Laminate Tape Drain Wire Tinned annealed copper Binder Tape polypropylene Braid/Armor Options Galvanized Steel Wire Braid (90%), Tinned Copper Wire Braid (90%) Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke Zero Halogen (TPO/TPPO to IEEE-1580, SHF-1 to IEC ). Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS LR, DNV, ABS, USCG, Transport Canada Marine Safety. Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 14 1p 18 1p p 18 (quad) 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p18 24p p18 27p p 18 36p
15 Flexible Shipboard Collective Screened Braided/Armored Instrumentation RS series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 (quad) 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 (quad) 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p Number of Number of Overall Diameter Minimum Max Approx Triads (t) x Triads (t) (inches) Bending Radius Current Weight (mm 2 ) Min Max (inches) 1t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
16 Flexible Shipboard Individual & Collective Screened Instrumentation EW series APPLICATION Flexible Instrumentation cables suitable for all marine applications CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Screen Individual and Collective Drain Wire Tinned annealed copper Assembly Components cabled with filler as required and overall binder tape Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 16 1p 18 1p p 18 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p18 24p p18 27p p 18 36p
17 Flexible Shipboard Individual & Collective Screened Instrumentation EW series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
18 Flexible Shipboard Individual & Collective Screened Braided/Armored Instrumentation EG series APPLICATION Flexible Instrumentation cables suitable for all marine applications where mechanical or EMC protection is required CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Screen Individual and Collective Aluminum/Laminate Tape Drain Wire Tinned annealed copper Isolation Tape Polyester Assembly Components cabled with filler as required and overall binder tape Bedding Tape Polypropylene Braid/Armor Options Galvanized Steel Wire Braid (90%), Tinned Copper Wire Braid (90%) Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (TOP/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 18 1p 18 1p p 18 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p18 24p p18 27p p 18 36p
19 Flexible Shipboard Individual & Collective Screened Braided/Armored Instrumentation EG series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
20 Flexible Shipboard Fire Resistant Power & Control RR Series APPLICATION Flexible shipboard cable is suitable for all marine applications where circuit integrity is required under fire conditions CONSTRUCTION Conductor Finely stranded annealed tinned copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 (available in plain or tinned) Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen. Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke Zero halogen (TPO/TPPO to IEEE-1580, SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Flame Barrier Fire Resistant, Halogen Free, Glass Mica Tape Assembly Conductors cabled with filler as required and overall binder tape or Aluminum/Polyester Shield + drain wire Ripcord High strength ripcord under jacket Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze. OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts STANDARDS ASTM B3-01 ASTMB33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC IEC IEC IEC (A) IEC &2 IEC & 2 APPROVALS LR, DNV, ABS, USCG, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil mm 2 Min Max (inches) (amps) IEEE (amps) IEC (kg/km) 20 1c 10 AWG 1C c 8 AWG 1C c 6 AWG 1C c 4 AWG 1C c 2 AWG 1C c 1 AWG 1C c 2/0 AWG 1C c 3/0 AWG 1C c 236McM 1C c 296 McM 1C c 365 McM 1C c 473 McM 1C c 592 McM 1C c 789 McM 1C c 986 McM 1c c 1243 McM 1c
21 Flexible Shipboard Fire Resistant Power & Control RR Series Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil mm 2 Min Max (inches) (amps) IEEE (amps) IEC (kg/km) 2c 16 AWG 2c c 14 AWG 2c c 12 AWG 2c c 10 AWG 2c c 8 AWG 2c c 6 AWG 2c c 4 AWG 2c c 2 AWG 2c c 16 AWG 3c c 14 AWG 3c c 12 AWG 3c c 10 AWG 3c c 8 AWG 3c c 6 AWG 3c c 4 AWG 3c c 2 AWG 3c c 1 AWG 3c c 2/0 AWG 3c c 3/0 AWG 3c c 236 McM 3c c 296 McM 3c c 365 McM 3c c 473 McM 3c c 592 McM 3c c 16 AWG 4c c 14 AWG 4c c 12 AWG 4c c 10 AWG 4c c 8 AWG 4c c 6 AWG 4c c 4 AWG 4c c 2 AWG 4c c 1 AWG 4c c 2/0 AWG 4c c 3/0 AWG 4c c 236 McM 4c c 296 McM 4c c 365 McM 4c c 16 AWG 5c c 14 AWG 5c c 12 AWG 5c c 10 AWG 5c c 8 AWG 5c c 6 AWG 5c c 4 AWG 5c c 2 AWG 5c c 1 AWG 5c c 16 AWG 7c c 16 AWG 12c c 16 AWG 19c c 16 AWG 24c c 16 AWG 27c c 16 AWG 33c c 16 AWG 37c c 14 AWG 7c c 14 AWG 12c c 14 AWG 19c c 14 AWG 24c c 14 AWG 27c c 14 AWG 33c c 14 AWG 37c
22 Flexible Shipboard Fire Resistant Braided/ Armored Power & Control BH series APPLICATION Flexible shipboard cables suitable for all marine applications where circuit integrity is required under fire conditions and mechanical or EMC protection is also required CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Flame Barrier Fire Resistant, Halogen Free, Glass Mica Tape Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Assembly Conductors cabled with filler as required and overall binder tape. Bedding Tape Polypropylene Braid/Armor Options Galvanized Steel Wire Braid (90%), Tinned Copper Wire Braid (90%) (also available with drain wire under braid) Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, low Smoke, Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil mm 2 Min Max (inches) (amps) IEEE (amps) IEC (kg/km) 22 1c 10 AWG 1C c 8 AWG 1C c 6 AWG 1C c 4 AWG 1C c 2 AWG 1C c 1 AWG 1C c 2/0 AWG 1C c 3/0 AWG 1C c 236McM 1C c 296 McM 1C c 365 McM 1C c 473 McM 1C c 592 McM 1C c 789 McM 1C c 986 McM 1c c 1243 McM 1c
23 Flexible Shipboard Fire Resistant Braided/ Armored Power & Control BH series Number of Number of Overall Diameter Minimum Max Max Approx Conductors x Conductors x (inches) Bending Radius Current Current Weight AWG/kcmil mm 2 Min Max (inches) (amps) IEEE (amps) IEC (kg/km) 2c 16 AWG 2c c 14 AWG 2c c 12 AWG 2c c 10 AWG 2c c 8 AWG 2c c 6 AWG 2c c 4 AWG 2c c 2 AWG 2c c 16 AWG 3c c 14 AWG 3c c 12 AWG 3c c 10 AWG 3c c 8 AWG 3c c 6 AWG 3c c 4 AWG 3c c 2 AWG 3c c 1 AWG 3c c 2/0 AWG 3c c 3/0 AWG 3c c 236 McM 3c c 296 McM 3c c 365 McM 3c c 473 McM 3c c 592 McM 3c c 16 AWG 4c c 14 AWG 4c c 12 AWG 4c c 10 AWG 4c c 8 AWG 4c c 6 AWG 4c c 4 AWG 4c c 2 AWG 4c c 1 AWG 4c c 2/0 AWG 4c c 3/0 AWG 4c c 236 McM 4c c 296 McM 4c c 365 McM 4c c 16 AWG 5c c 14 AWG 5c c 12 AWG 5c c 10 AWG 5c c 8 AWG 5c c 6 AWG 5c c 4 AWG 5c c 2 AWG 5c c 1 AWG 5c c 16 AWG 7c c 16 AWG 12c c 16 AWG 19c c 16 AWG 24c c 16 AWG 27c c 16 AWG 33c c 16 AWG 37c c 14 AWG 7c c 14 AWG 12c c 14 AWG 19c c 14 AWG 24c c 14 AWG 27c c 14 AWG 33c c 14 AWG 37c
24 Flexible Shipboard Fire Resistant Collective Screened Instrumentation ES series APPLICATION Flexible Instrumentation cables suitable for all marine applications where circuit integrity is required under fire conditions CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11. Flame Barrier Fire Resistant, Halogen Free, Glass Mica Tape Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Assembly Components cabled with filler as required and overall binder tape Screen Aluminum/Laminate Tape Drain Wire Tinned annealed copper Binder Tape Polyester Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 24 1p 18 1p p 18 (quad) 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p18 24p p18 27p p 18 36p
25 Flexible Shipboard Fire Resistant Collective Screened Instrumentation ES series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 (quad) 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 (quad) 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
26 Flexible Shipboard Collective Screened Braided/ Armored Instrumentation FJ series APPLICATION Flexible Instrumentation cables suitable for all marine applications where circuit integrity is required under fire conditions and mechanical or EMC protection is also required CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 Flame Barrier Fire Resistant, Halogen Free, Glass Mica Tape Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSX to IEEE- 1580) (HF-90 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Assembly Components cabled with filler as required and overall binder tape Screen Aluminum/Laminate Tape Drain Wire Tinned annealed copper Binder Tape Polyester Bedding Tape Polypropylene Braid/Armor Options Galvanized Steel Wire Braid (90%), Tinned Copper Wire Braid (90%) Ripcord High strength ripcord under jacket Jacket LSFLEX S-50, Polyolefinic, Flame Retardant, Low Smoke, Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Armor (Optional) All constructions are available with Overbraid Armor of either Aluminum or Bronze OPERATING TEMP -40 C to 90 C VOLTAGE RATING 250 Volts STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No.245 for Cold Bend (-40 C) and Cold Impact (-35 C) Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 26 1p 18 1p p 18 (quad) 2p p 18 4p p 18 8p p 18 10p p 18 12p p 18 16p p 18 20p p 18 24p p 18 27p p 18 36p
27 Flexible Shipboard Fire Resistant Collective Screened Braided/Armored Instrumentation FJ series Number of Number of Overall Diameter Minimum Max Approx Pairs (p) x Pairs (p) x (inches) Bending Radius Current Weight AWG (mm 2 ) Min Max (inches) (amps) IEEE (kg/km) 1p 16 1p p 16 (quad) 2p p 16 4p p 16 8p p 16 10p p 16 12p p 16 16p p 16 20p p 16 24p p 16 27p p 16 36p p 14 1p p 14 (quad) 2p p 14 4p p 14 8p p 14 10p p 14 12p p 14 16p p 14 20p p 14 24p p 14 27p p 14 36p t 18 1t t 18 3t t 18 4t t 18 7t t 16 1t t 16 3t t 16 4t t 16 7t t 14 1t t 14 3t t 14 4t t 14 7t
28 Flexible Shipboard Braided Variable Frequency Drive Cable DF series APPLICATION Flexible Variable Frequency Drive Cables suitable for all marine applications where mechanical or EMC protection is required CONSTRUCTION Conductor Finely stranded annealed copper to ASTM B3-01, ASTM B33-00 and IEC Significantly exceeds IEEE-1580 Table 11 (Available in plain or tinned) Insulation LSFLEX R-30, Cross-linked, Polyolefinic, Thermoset, Flame Retardant, Low Smoke, Zero Halogen (LSF to IEEE-1580) (HF-90 to IEC ) Includes ripcord on 10mm2 and larger Assembly Three Circuit Conductors and Three Ground Wires cabled with filler as required Bedding Tape Polypropylene or Polyester Braid Tinned Copper Wire Braid (90%) with Aluminum/ Polyester Tape (100%) Ripcord: High strength ripcord under jacket Jacket LSFLEX S-50, Flame Retardant, Low Smoke, Zero Halogen (TPO/TPPO to IEEE-1580) (SHF-1 to IEC ) Splash resistant to oil, skydrol, gasoline, acid, sea water. Resists ozone and UV. Pressure extruded (without fillers) OPERATING TEMP -40 C to 90 C VOLTAGE RATING 600/1000 Volts CORE IDENTIFICATION PF = BK WH RE + 3GN Grounds STANDARDS ASTM B3-01 ASTM B33-00 IEEE-45 IEEE-1580 IEEE-1202 IEC IEC IEC IEC IEC (A) IEC &2 IEC &2 APPROVALS USCG, ABS, LR, DNV, BV, Transport Canada Marine Safety Cable constructions, Jackets, and Inner components to UL 1309 CSA C22.2 No. 245 for Cold Bend (-40 C) and Cold Impact (-35 C) Reference in ABS Certification for Part Series TW003. Number of Ground Size Diameter Overall Minimum Approx Ampacity Conductors ( c ) mm 2 Over Shield Diameter Bending Radius Weight at 90C x mm 2 (inches) Nom. (inches) (inches) (kg/km) (amps) 28 3c c c c c c c c c c c
29 UL 1426 Boat Cable BC 5W2 Primary Wire APPLICATION Flexible UL Standard boat cable suitable for all marine applications CONSTRUCTION Conductor Finely stranded Type III Tinned Copper Insulation Ultra Flexible Polyvinyl Chloride. Resists Acids, Abrasion, Alkali, Flame, Gasoline, Moisture, and Oil Color To Customer Specification OPERATING TEMP -20 C to 105 C, BC-5W2 (105 C Dry, 75 C Wet) VOLTAGE RATING 600 Volts STANDARDS UL Standard 1426 BC-5W2 (Electric Cable for Boat) ABYC E-11, NMMA, USCG 33 CFR Part , , SAE J378, 1127, AWG Item # Color Length (Ft) Lt. Blue Black Dk. Blue Brown Green Grey Item # Color Length (Ft) Orange Pink Purple Red White Yellow
30 UL 1426 Boat Cable BC 5W2 Primary Wire 14 AWG 12 AWG 10 AWG Item # Color Length (Ft) Black Dk. Blue Brown Green Grey Orange Pink Purple Red White Yellow Item # Color Length (Ft) Black Dk. Blue Brown Green Red White Yellow Item # Color Length (Ft) Black Dk. Blue Brown Green Red White Yellow
31 UL 1426 Boat Cable BC 5W2 Battery Cable 8 AWG 6 AWG 4 AWG Item # Color Length (Ft) Black Brown Green Red White Yellow Item # Color Length (Ft) Black Green Red White Item # Color Length (Ft) Black Green Red White Yellow AWG 1/0 AWG 2/0 AWG Item # Color Length (Ft) Black Red Yellow Item # Color Length (Ft) Black Red Yellow Item #t Color Length (Ft) Black Red Yellow AWG 3/0 AWG 4/0 AWG Item # Color Length (Ft) Black Red Yellow Item # Color Length (Ft) Black Red Yellow Item # Color Length (Ft) Black Red Yellow
32 UL 1426 Boat Cable BC 5W2 Duplex & Triplex Item # Cable Size Length (Ft) Color Duplex Flat Item # Cable Size Length (Ft) Color C 18 AWG 100 Red/Black C 16 AWG 100 Red/Black C 14 AWG 100 Red/Black C 12 AWG 100 Red/Black C 10 AWG 100 Red/Black C 8 AWG 100 Red/Black C 18 AWG 100 Red/Yellow C 16 AWG 100 Red/Yellow C 14 AWG 100 Red/Yellow C 12 AWG 100 Red/Yellow C 10 AWG 100 Red/Yellow C 8 AWG 100 Red/Yellow Item # Cable Size Length (Ft) Color 32 Triplex Flat Item # Cable Size Length (Ft) Color C 16 AWG 100 Bk/Wh/G C 14 AWG 100 Bk/Wh/G C 12 AWG 100 Bk/Wh/G C 10 AWG 100 Bk/Wh/G C 8 AWG 100 Bk/Wh/G C 6 AWG 100 Bk/Wh/G
33 ELECTRICAL ACCESSORIES 33
34 TERMINAL & CONNECTOR Nylon Insulated Ring Terminal - Double Crimp Vinyl Insulated Ring Terminal - Single Crimp 34 Item # Wire Size Stud Size Qty/Pkg AWG # AWG 1/ AWG # AWG 1/ AWG 5/ AWG # AWG 1/ AWG 5/ AWG 3/ Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG 1/ AWG 5/ AWG # AWG # AWG 1/ AWG 5/ AWG # AWG # AWG 1/ AWG 5/ AWG 3/ AWG 1/
35 TERMINAL & CONNECTOR Heat Shrink Ring Terminal Vinyl Insulated Spade (Fork) Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG 1/ AWG # AWG # AWG 1/ AWG 5/ AWG # AWG # AWG 1/ AWG 5/ AWG 3/ Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG 1/ AWG # AWG # AWG 1/ AWG # AWG # AWG 1/ AWG 5/
36 TERMINAL & CONNECTOR Nylon Flanged Spade Heat Shrink Flanged Spade Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG # AWG # AWG # AWG # Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG # AWG # AWG # AWG # Heat Shrink Locking Spade TERMINAL & CONNECTOR Item # Wire Size Stud Size Qty/Pkg AWG # AWG # AWG # AWG #
37 TERMINAL & CONNECTOR Vinyl Insulated Butt Splice Connector Nylon Insulated Butt Splice Connector Item # Wire Size Qty/Pkg AWG AWG AWG Item # Wire Size Qty/Pkg AWG AWG AWG TERMINAL & CONNECTOR Heat Shrink Butt Splice Connector Heat Shrink Step Down Butt Splice Item # Wire Size Qty/Pkg AWG AWG AWG Item # Wire Size Qty/Pkg AWG to AWG AWG to AWG AWG to 8 AWG
38 TERMINAL & CONNECTOR Nylon Fully Insulated Disconnect - Double Crimp Heat Shrink Fully Insulated Disconnect Item # Specification Wire Size Qty/Pkg Male Disconnect AWG Male Disconnect AWG Male Disconnect AWG Female Disconnect AWG Female Disconnect AWG Female Disconnect AWG Item # Specification Wire Size Qty/Pkg Male Disconnect AWG Male Disconnect AWG Male Disconnect AWG Female Disconnect AWG Female Disconnect AWG Female Disconnect AWG Heat Shrink Bullet Plug & Receptacles TERMINAL & CONNECTOR Item # Specification Diameter Wire Size Qty/Pkg Heat Shrink Bullet Plugs AWG Heat Shrink Bullet Receptacles AWG Heat Shrink Bullet Plugs AWG Heat Shrink Bullet Receptacles AWG Heat Shrink Bullet Plugs AWG Heat Shrink Bullet Receptacles AWG
39 HEAVY DUTY LUGS Material: Feature: Tinned Copper Flared barrel entry for ease of wire insertion UL/CUL listed Item # Wire Size Stud Size Qty/Pkg AWG 5/ AWG 3/ AWG 5/ AWG 3/ AWG 5/ AWG 3/ /0 AWG 5/ /0 AWG 3/ /0 AWG 5/ /0 AWG 3/ /0 AWG 5/ /0 AWG 3/
40 POWER DISTRIBUTION POST Single Point with Insulator 8 Point with Insulator Feature Material Used to connect two or more voltage lines Available with large or small base Max Voltage is 48 vdc Base Material: Glass-Filled Nylon Connection Post: Stainless Steel Connection Nuts: Stainless Steel Flat Washer: Stainless Steel Spring washer: Stainless Steel Feature Material Create reliable, trouble-free circuit paths to control systems Hook up negative return lines to single cable Connecction plate made from nickel-plated copper which gives 40% better conductivity than tin-plating Max voltage - 48 vdc Available Base Material: Glass-Filled Nylon Connection Post: Stainless steel Connection Nuts: Zinc-plated copper Connection Screws: Stainless Steel Item # Base Size Mounting Thread Size Colour Center (inch) (post) Item # Post Size Connecting Mounting Colour Screws Center (inch) Large 2.5 5/16 Black Large 2.5 3/8 Black Large 2.5 3/8 Red /16 # Black /8 # Black /8 # Red ANL FUSE HOLDER Feature Material Max Amperage: 300 amps at 12 vdc Max Voltage: 48 vdc Glass-Filled Nylon Item # Max Fuse Max Continuous Max Rating DC Volts Duty Amperage Amerpage 1 minute
41 INSULATOR CAP Feature Protect terminal connections from accidental shorts comply with ABYC & USCG Item # Specification Wire Size Color Qty/Pkg Lug & Ring Type 8-4 AWG Black Red Yellow Black Red Yellow Black/Red 1/ Yellow/Red 1/ /0 AWG Black Red Yellow Black Red Yellow Black/Red 1/ Yellow/Red 1/ /0-4/0 AWG Black Red Yellow Black Red Yellow Black/Red 1/ Yellow/Red 1/ Swivel Top Type Up to 4/0 AWG Black Red Yellow Black Red Yellow Black/Red 1/ Yellow/Red 1/ Marine Wing Nut Type Up to 4/0 AWG Black Red Yellow Black Red Yellow Black/Red 1/ Yellow/Red 1/1 41
42 NYLON CABLE TIE Approval CUL, DNV, VDE, GL, Lloyd s Register, CE, ABS, RoHS Material Nylon 66 Operating Temp Capacity up to 85C Item # Cable Tie Cable Tie Maximum Tensile Color Qty/Pkg Length Width Bundle Strength (inch) (mm) Diameter (mm) lb/8kg Black lb/8kg Black lb/8kg Natural lb/8kg Natural lb/18KG Black lb/18KG Black lb/18KG Natural lb/18KG Natural lb/18KG Black lb/18KG Black lb/18KG Natural lb/18KG Natural lb/18KG Black lb/18KG Black lb/18KG Natural lb/18KG Natural lb/18KG Black lb/18KG Black lb/18KG Natural lb/18KG Natural lb/22KG Black lb/22KG Black lb/22KG Natural lb/22KG Natural lb/22KG Black lb/22KG Black lb/22KG Natural lb/22KG Natural lb/22KG Black lb/22KG Black lb/22KG Natural lb/22KG Natural lb/55KG Black lb/55KG Black lb/55KG Natural lb/55KG Natural 100
43 CABLE TIE MOUNT Saddle Type Nylon Cable Clamp Material UL approved Nylon 66, 94V-2 Feature Designed to provide maximum stability to wire bundles. Item # Screw Maximum color Qty/pkg Mount # cable tie width (mm) #10 9 Black #10 9 Black #10 9 Black #10 9 Black #10 9 Natural #10 9 Natural #10 9 Natural #10 9 Natural 100 CABLE TIE MOUNT Material UL approved Nylon 66, 94V-2 Feature Adhesive Type Designed to support light weight wire bundles when properly applied on any clean, smooth, grease-free surface. For heavy support, mounting hole is provided for screws. Item # Screw Maximum color Qty/pkg Mount # cable tie width (mm) x 1 #10 Black x 1 #10 Black x 1 #10 Black x 1 #10 Black x 1 #10 Natural x 1 #10 Natural x 1 #10 Natural x 1 #10 Natural 100 Material UL approved Nylon 66, 94V-2 Feature Interiror edges are radiused to protect cable insulation Item # Nominal Color Qty/Pkg Diameter (inches) /4 Natural /4 Natural /4 Natural /4 Black /4 Black /4 Black /16 Natural /16 Natural /16 Natural /16 Black /16 Black /16 Black /8 Natural /8 Natural /8 Natural /8 Black /8 Black /8 Black /2 Natural /2 Natural /2 Natural /2 Black /2 Black /2 Black /8 Natural /8 Natural /8 Natural /8 Black /8 Black /8 Black /4 Natural /4 Natural /4 Natural /4 Black /4 Black /4 Black Natural Natural Natural Black Black Black /4 Natural /4 Natural /4 Natural /4 Black /4 Black /4 Black /2 Natural /2 Natural /2 Natural /2 Black /2 Black /2 Black
44 Stainless Steel Cushion Clamp Thick Adhesive Lined Shrink Tube Materal Feature Stainless Steel with rubber Flammibility UL 94V-2 Absorbs shocks and vibration Prevents corrosion Item # Nominal Diameter (inch) Qty/Pkg / / / / / / / / / / / / / / / / / / / / Material Co-extrusion of polyolefin and hot-melt adhesive Feature Provide both insulation and sealing Protect bundles of wires and metal tubes against water and moisture Flexible and thick adhesive lined to bond with plastics, rubber and metals Temperature Operating Temp: -45 C ~125 C Shrinking Temp: starts at 70 C, and shrunk totally at 125 C Shrink Ratio 3:1 Item # Diameter Color Length (inch) Qty/Pkg /8 Black Red Black Red /16 Black Red Black Red /4 Black Red Black Red /8 Black Red Black Red /2 Black Red Black Red /4 Black Red Black Red Black Red Black Red
45 Horizon V74 Horizon RP97 Horizon E88
46 Horseshoe Way, Richmond, BC V7A 4S5 Canada T F
CIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationINDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS
INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C
More informationDLO Flexible Power Cable
Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C
More informationOver 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships
Tray Cable Our Commitment Our commitment to our customers is simple - we deliver even when others can t. As one of Canada s largest wire, cable and data communication distributors for over 35 years, Texcan
More informationFor tough, seaworthy wire
Dearborn Marine The Premier Choice for Marine Applications For tough, seaworthy wire and cable, Alpha Wire s Dearborn brand of products delivers performance in the most challenging environments for electrical
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationOFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
More informationLV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments
ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationMongoose PT Platform Shale Shaker
Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of
More informationA NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES
A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationCABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES
CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective
More informationLow Voltage AIRGUARD. A proven, rugged product for harsh environments
Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature LAPP products are available from MARYLAND METRICS P.O. Box 61 Owings Mills, MD 1117 USA ph:(10)8-10 (800)68-180 fx:(10)8-1 (800)87-99 web: http://mdmetric.com
More informationShip and Offhsore. Approved cables for ship- and offshoreindustry
Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More informationFLAME RETARDANT INSTRUMENTATION CABLE. Application Standard
FLAME RETARDANT INSTRUMENTATION CABLE Designation 150/250V TTY, FA-TTY, 150/250V TTYC, FA-TTYC, 150/250V TTYCY, FA-TTYCY 250V TTYC - Design guide : JIS C 3410(2010) - Flameretardant : IEC 60332-1 : IEC
More information600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength thermosetting EPR-based insulation, Type XHHW-2, cabled with bare copper grounding conductors and fillers,
More information600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables
Applications Multiconductor cable with stranded copper conductors, extruded high dielectric strength cross-linked polyethylene (XLPE) insulation, Type XHHW-2, cabled with bare copper grounding conductors
More informationServo Cable Selection
Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationWIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable
05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationArmoured Instrumentation Cables to BS6883
Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationHigh Temperature Flexible Control Cable OLFLEX
High Temperature Flexible Control Cable 6 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-60-Main Office: (60) 88-900-Outside Local Area: (800) 8-900-www.stevenengineering.com
More informationCommunication, Control, and Industrial Cable
Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad
More informationExtremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488
ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:
More informationRAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø
RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)
More informationArmoured Power and Control Cables to BS7917
1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit
More informationArmoured Power and Control Cables Fire Resistant
Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity
More informationÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary
TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable
More informationCopyright June Nexans
Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical
More informationArmoured Power and Control Cables to BS6883
Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in
More informationScreened servo cable with PUR outer sheath for highly dynamic power chain application - certified
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and
More informationTRAXLINE CABLES FOR MOTION
TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables
More information02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser
TECHNICAL INFORMATION INFORMATION TECHNIQUE INFORMACIÓN TÉCNICA WIRE/CABLE DISPLAYS PRÉSENTOIRS POUR FILS/CÂBLES EXHIBIDORES DE CABLES For all vehicle wiring maintenance and repairs, Grote offers a wide
More informationShielded Fire Alarm Cables
PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum
More informationTIGER BRAND MINING CABLES
TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation
More informationENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE
ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE
More informationCreating. There is one basic question every customer needs to address when creating custom
Wire and cable have a very deep history in industry, and remain indispensable for a wide variety of applications today. In our current digitized and online landscape, getting the best wire and cable is
More informationOLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from
LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray
More informationCCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations
CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line
More informationHigh Temperature Flexible Control Cable
High Temperature Flexible Control Cable 0 High Temperature Flexible Control Cable SILFLEX UL/CSA UL/CSA/CE 0 High Temperature Silicone Control Cable with UL/CSA SILFLEX SiHF CE 0 High Temperature Silicone
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationSection 4. Multi-Conductor
Section 4. 63 Table of Contents ÖLFLEX...66 ÖLFLEX CLASSIC 100 Flexible Power and Control Cable...67 ÖLFLEX CLASSIC 110 Flexible Control Cable Number Coded...68 ÖLFLEX CLASSIC 110 Black 1000V UV Resistant
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationT E C H N I C A L D A T A for
Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU
More informationData sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC
More informationDNVGL-CP-0400 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0400 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationAddison Medium Voltage Cables
Addison Medium Voltage Cables www.addison-cables.com www.addison-tech.com 1 Caledonian Medium Voltage Cables(ICEA) Company Profile Caledonian. established in 1978.offers one of the most complete lines
More informationDetailed Specifications & Technical Data
RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1
More information15 years of experience
Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since
More informationSERV-RITE Wire. Thermocouple and Extension Wire. Thermal Devices, Inc. Mount Airy, Maryland USA
Manufactured to Exact Specifications Since 1914, SERV-RITE thermocouple wire and thermocouple extension wire have been recognized for premium performance and reliability. All stock and custom wire is manufactured
More informationWire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3
Wire Gauge Chart Amp Capacity Total Length of Wire in Circuit from Power Supply to Accessory 12 Volt 6 Volt 10-ft 20-ft 30-ft 40-ft 50-ft 60-ft 70-ft 80-ft 90-ft 100-ft 1.0 0.5 18 ga 18 ga 18 ga 18 ga
More informationGround Clamps Cable Tray
commercial and industrial fittings: ing Fittings and Solderless Connectors Clamps Cable Tray Terminates ground wire to cable tray. For aluminum or copper conductors. 1 4 hex wrench tightens both tray and
More information3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)
Design Parameters Description Three conductor cable with stranded copper conductors, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX
More informationWELCOME On-Line Catalog Features
High-Endurance Cabling > THE EXCEPTIONAL CHOICE FOR PEACE OF MIND WELCOME On-Line Catalog Features Join the Wire Wizard for a quick, informative tour showing the interactive features of our catalogs View
More informationElectronically published by ABS Piraeus. Reference T , dated 30-AUG-2018.
UNTEL KABLOLARI SAYI VE TICARET ANONIM SIRKETI MAKINE OSB, 6.CAD. NO: 4 41455 DILOVASI-GEBZE KOCAELI Turkey Telephone: + 90 262 722 93 30 Fax: + 90 262 722 94 92 Email: info@untel.com.tr Web: www.untel.com.tr
More informationFieldLink MC at 20 x outer diameter Torsion
Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC 60228 Cl.5 and Cl. 6, insulation
More informationMULTIMEDIA & DATA TRANSMISSION
NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling
More informationFLEXIBLE MULTI CORE CABLES
FLEXIBLE MULTI FTM Series...22 MTSV Series...23 TW-T Series...24 PF Series...25 OD Series... 27 HD Series...28 MLG2 Multi Series...30 HO Plus Series...32 HR Series... 34 HRP Series...36 FX Series... 37
More informationSINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V
LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded
More informationK20 & L120 LSZH Armoured F/FTP Cat6 Cables
K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationABOUT US ABOUT US 1 CRANE CABLES
ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its
More informationInstall & Go Cat.8 S/FTP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationMulti-Paired Cable Product Finder
Multi-Paired Cable Product Finder Technical Information NO. STRAND TYPE C00 U......................, 0 0 C000 F........................ C0 FB....................... C FB....................... C0 F.......................
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true engineering
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More information3-10. General Quick Selection Introduction 3-Cordsets PannelConnect Safety. Connection. Network Media
16 AWG, STOOW PVC Heavy duty STOOW-A 16 AWG cable PVC jacket offers good oil and chemical 2-, 3-, 4-, 5-, and 6-pin configurations Contact Material Gold-plated palladium/nickel Cable Type Oil-resistant
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationMarineLine YOZp 0,6/1 kv
Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame
More informationSPEC 44. Wire and cable
SPEC 44 Wire and cable Applications SPEC 44 wire has a dual wall construction which combines the outstanding physical and electrical characteristics of radiation crosslinked polyalkene with the excellent
More informationCoaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums
4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable
More informationEXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)
XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance
More informationWIRE AND CABLE SECTION M WIRE AND CABLE. TEW / TEWN and TR-64 Wire. SPT1 / SPT2 / SEW1 AND SEW2 Wire. SVT / SJT / SO AND SOOW Cords
SECTION M TEW / TEWN and TR-64 Wire SPT / SPT2 / SEW AND SEW2 Wire SVT / SJT / SO AND SOOW Cords Clear Braided Multi Conductor Cable M2 M3 M4 M5 M2 TEW / TEWN AND TR-64 WIRE TEW and TEWN - Single Conductor
More informationADVANCED FLAT CABLE SOLUTIONS
ADVANCED FLAT CABLE SOLUTIONS ONTENTS Contents F Flat Ribbon Cable Overview 03 Microzip Summary Sheet 04 Microzip TPO Solid & Stranded 0.025 inch (0.635 mm) 05 Microzip PVC Solid & Stranded 0.025 inch
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,
More informationDETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG
INCH-POUND MIL-DTL-49285/22B 27 March 2018 SUPERSEDING MIL DTL 49285/22A 1 March 2010 DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG Inactive
More informationHigh Performance Wire and Cable
SPEC 55 Product Facts Resistant to electrical arc tracking in wet or dry conditions Single or dual wall constructions Small size, ultra light weight Exceptional chemical resistance -65 C to 200 C [-85
More informationSTANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4
Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked
More informationC400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector
More informationAirport Cables & Connectors
Airport Cables & Connectors Aircraft Cable & Connector Products Descrip on 0 Hz Single Jacket No Contact Sec on 0 Hz Single Jacket With Replaceable Durable Hard Nose Contact Sec on 0 Hz Single Jacket -
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More information