Product information. Marine, Oil & Gas.
|
|
- Gabriella Byrd
- 5 years ago
- Views:
Transcription
1 Product information Marine, Oil & Gas
2 DRAKA Product information MOG 2010
3 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded challenging marine and offshore demands for electrical and data solutions. As a leading provider of cabling solutions, we are backed by quality manufacturing and local inventory in every key marine and offshore market. By focusing on customer needs, Draka employees deliver trusted, timely and dependable service for ships, oil rigs, subsea and offshore wind farms. We take pleasure in presenting this catalog with our Shipboard cables. The ShipLine Plus range is our standard range suitable for all ships including dredging vessels, marine vessels and FPSO s. The cables have an innersheet and circular non-compacted s for increased flexibility and ease of installation. For applications in less harsh environment like yachts and cruise vessels, we have the ShipLine range. This range is lighter and more compact. In addition to these ranges we supply an extensive range of data cables, medium voltage cables, offshore cables and special cables. You will find members of the Draka team working all around the globe, with strong presence in your home market. They represent literally hundreds of years of experience with product development, quality management and on-time project delivery. This unique expertise and understanding of the market enables Draka to provide you with the services you need to meet your toughest marine and offshore challenge. Please visit to learn more about what Draka can do to help you and for more the most recent information about our products. Yours sincerely, Draka For use in emergency systems where Fire Resistant cables (IEC 60331) is needed, we have our ShipLine FR cables available from stock. ShipLine Plus halogen-free international standards circular s easy to install ShipLine halogen-free international standards light-weight cost-saving ShipLine Fire Resistant halogen-free international standards fire resistant DRAKA Product information MOG
4 Sheath colours Power Instrument/signal Fire resistant black grey green Core identification 1 core black 2 cores blue brown 3 cores brown black grey 4 cores blue - brown black grey 5 cores blue - brown black grey black 6 cores and above white with black numbers Earth core yellow/ green (optional) Standards applied IEC IEC IEC IEC IEC IEC IEC IEC IEC IEC A IEC ,2 IEC ,2 Electrical installations in ships Construction, testing and installation Low voltage shipboard power cables Insulating materials for shipboard power cables Single and multicore cables with extruded solid insulation for rated voltages 0.6/ 1 kv Sheating materials for shipboard power and telecommunication cables Shipboard telecommunication cables and radio frequency cables General instrumentation, control and communication cables Shipboard multicore cables for control circuits Tests for electric cables under fire conditions Circuit integrity Tests on electric cables under fire conditions Single vertical insulated wire or cable Tests on electric cables under fire conditions Vertical flame spread of vertically mounted bunched wires and cables, category A Tests on gases evolved during combustion of materials from cables Determination of the amount of halogen acid gas Determination of degree of acidity by measuring Ph and conductivity Measurement of smoke density of cables burning under defined conditions Test apparatus, test procedures and requirements Approvals American Bureau of Shipping Bureau Veritas Det Norske Veritas Germanischer Lloyd Lloyd s Register of Shipping Certification by other classification bureaus at request. 4 DRAKA Product information MOG 2010
5 Index ShipLine Plus Page TFXI 0.6/1 kv (HUSK) Power cable, unarmoured 6 TIOI 0.6/1 kv (HUSO) Power cable, armoured 8 TIOI (c) 250 V (HUCOM) Instrumentation cable, screened 11 ShipLine TI 0.6/1 kv Power cable, unarmoured 12 TXOI 0.6/1 kv Power cable, armoured 14 TXOI 250 V Instrumentation cable, screened 16 ShipLine Fire Resistant BI FR 0.6/1 kv Power cable, Fire Resistant, unarmoured 17 BXOI FR 0.6/1 kv Power cable, Fire Resistant, armoured 18 BXOI FR 250 V Instrumentation cable, Fire resistant, screened 19 Data cables Overview Data, FR, Video/Audio, CATV 20 Electrical characteristics of cables 21 Also available on request Offshore cables RFOU (NEK606) LV, MV, instrumentation (Mud resistant) BFOU (NEK606) LV, MV, instrumentation (Fire/Mud resistant) RFCU (UKOOA) LV, MV, instrumentation (Mud resistant) BFCU (UKOOA) LV, MV, instrumentation (Fire/Mud resistant) Type P (IEEE45) LV, MV, instrumentation (Mud resistant) HXXM (IEEE45/IEC) LV, MV, instrumentation (Fire resistant) Special cables Flexible EMC Dredging cable 0,6/1 kv and 1,8/3,6 kv NEK606 HCF 1100C NEK606 Artic Grade (Cold bend/cold impact) TFOI 6/10 kv (also other Voltage rates on request) Down hole Pump cable VFD cables Hulto EMC ShipLine Plus Fire Resistant BFXI 0.6/1 kv (HUSK FR) Power cable, Fire Resistant, not braided BIOI 0.6/1 kv (HUSO FR) Power cable, Fire Resistant, braided BIOI 250 V (HUCOM FR) Instrumentation cable, Fire resistant, braided For more information about these cables please visit DRAKA Product information MOG
6 ShipLine Plus TFXI 0.6/1 kv (HUSK) Halogen free shipboard and offshore cable Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Design stadard: IEC Max. temp.: 90 C * Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green: Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey > 4 cores + earth Yellow/green - White with black numbers * Temporary overload permissible up to 130 C Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Bedding F Halogen free material Armour/screen X No armouring Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and crosssection (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) x x x x x x x x x x x x x x x x x G G x x x working capacitance (nf/km) 3 6 DRAKA Product information MOG 2010
7 ShipLine Plus TFXI 0.6/1 kv (HUSK) Halogen free shipboard and offshore cable product number no. of cores and crosssection (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) x x x x x x x x x x G G G x x x x x x G G x x x x G x x x x x x working capacitance (nf/km) 3 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. 1 G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. DRAKA Product information MOG
8 ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Design standard: IEC Max. temp.: 90 C * Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey * Temporary overload permissible up to 130 C Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1 Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x x x x x x x x x x x x x x x x x x x G DRAKA Product information MOG 2010
9 ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self induc tance (mh/km) working capacitance (nf/km) G x x x x x x x x x x x x x G G x x x x x x x x x x x G G x x x x x x x x x x x x DRAKA Product information MOG
10 ShipLine Plus TIOI 0.6/1 kv (HUSO) Armoured halogen free shipboard and offshore cable Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. 1 G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. 10 DRAKA Product information MOG 2010
11 ShipLine Plus TIOI (c) 250 V (HUCOM) Armoured halogen free shipboard and offshore cable Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.A) Design standard: IEC Core identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc. 1x3 cores (triple) is identified with no. 1, 2 and 3 1x4 cores (quad): Pair no.1 core no. 1 and 2 Pair no.2 core no. 3 and 4 Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Lay up Numbered cores twisted to pair/triple/quad and wrapped with polyester tape. Pairs/triple/quad are laid up and collectively screened by aluminium polyester tape with tinned copper drain wire 0,5 mm 2. Inner sheath I Flame retardant halogen free thermoplastic compound, SHF1 Armour/screen O Tinned copper wire braid. PETP-tape. Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Grey product number no. of cores and cross-section (n x mm 2 ) core outer x2x x4x x2x x2x x2x x2x x2x x2x approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single pair/triple Single quad Multi pair Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature DRAKA Product information MOG
12 ShipLine TI 0.6/1 kv Halogen free shipboard and offshore cable Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.A) Design standard: IEC Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Four cores + earth (5G) Yellow/green - Blue - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded copper, 3-core cables 50 mm 2 sector shaped, other types circular Insulation T Crosslinked polyethylene, XLPE Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x x x x x G G G G x x x x x x x x x50 SS 6.8/ / x70 SS 8.2/ / x95 SS 10.9/ / x120 SS 12.2/ / G G G DRAKA Product information MOG 2010
13 ShipLine TI 0.6/1 kv Halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) G G G G x x x x x x x G G x x Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request. For single core and multi core (>5 cores) versions of TI-types, please refer to our TFXI-range (page 6). 1 SS = sector-shaped G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page Working capacitance for one-phase asymmetrical or three-phase symmetrical system. DRAKA Product information MOG
14 ShipLine TXOI 0.6/1 kv Armoured halogen free shipboard and offshore cable Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Design standard: IEC Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Single core Black Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers With yellow/green. Two cores + earth (3G) Yellow/green - Blue - Brown Three cores + earth (4G) Yellow/green - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded copper, 3-core cables 50 mm 2 sector shaped, other types circular Insulation T Crosslinked polyethylene, XLPE Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Black product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x x x x x x x x x x x x G G x x x x x x x DRAKA Product information MOG 2010
15 ShipLine TXOI 0.6/1 kv Armoured halogen free shipboard and offshore cable product number no. of cores and cross-section (n x mm 2 ) 1 crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 2 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x50 SS / / x70 SS / / x95 SS / / x120 SS / / x150 SS / / G G x x x x x x x x x x x x x x x x x Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 SS = sector-shaped G = including green/yellow 2 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: I. For singel core cables, Method G: 3 cores spaced in free air II. For multi-core cables, Method E: Multi-core cables in free air - For 3G core cables, the values for 2 loaded cores are given. - For 4 en 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page 2 3 Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected. DRAKA Product information MOG
16 ShipLine TXOI (c) 250 V Armoured halogen free shipboard and offshore cable Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.A) Design standard: IEC Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Pair identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc. 1x3 cores (triple) is identified with no. 1, 2 and 3 1x4 cores (quad): Pair no.1 core no. 1 and 2 Pair no.2 core no. 3 and 4 Construction CODE LETTER Conductor Annealed stranded circular copper Insulation T Crosslinked polyethylene, XLPE Lay up Numbered white cores twisted in pairs. (Two pair version stranded into a star quad). The pairs are twisted with different lay lengths to reduce mutual interference. Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Grey product number no. of cores and cross-section (n x mm 2 ) core outer x2x x4x x2x x4x x2x x2x x2x x2x x2x x2x approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single-pair Multi-pair Single-pair Multi-pair Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature 16 DRAKA Product information MOG 2010
17 ShipLine Fire Resistant BI FR 0.6/1 kv Halogen free shipboard and offshore cable, fire resistant Application Unarmoured power and control cable for fixed installations on ships and offshore units where cable protection is not required. For instrumentation, communication, control, alarm, emergency and critical systems. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Fire resistant - According to IEC Design standard: IEC Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Core identification Two cores Blue - Brown Three cores Brown - Black - Grey Four cores Blue - Brown - Black - Grey Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 1 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x x x x x x Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: Method E: Multi-core cables in free air - For 4 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures and cables laid in bundles are given on page Working capacitance for one-phase asymmetrical or three-phase symmetrical system. DRAKA Product information MOG
18 ShipLine Fire Resistant BXOI FR 0.6/1 kv Armoured halogen free shipboard and offshore cable, fire resistant Application Armoured power-, control- and lighting cable for fixed installations on ships and offshore units where cable protection is required. For instrumentation, communication, control, alarm, emergency and critical systems in both EX- and safe areas. Suitable for both indoor and outdoor installations. Design standard: IEC Max. temp.: 90 C (temporary overload permissible up to 130 C) Nominal voltage: 0.6/1 kv Test voltage: 3.5 kv AC Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Fire resistant - According to IEC Pair identification Two cores Blue - Brown Three cores Brown - Black - Grey Five cores Blue - Brown - Black - Grey - Black > 5 cores White with black numbers Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Inner sheath X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) crosssectional area of the earth lead (mm 2 ) core outer approximate weight (kg/km) maximum current rating (A) 1 resistance at 20 C DC resistance at 90 C, 60 Hz self inductance (mh/km) working capacitance (nf/km) x x x x x x x x x > x >165 Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature Other cross-sections and numbers of cores are available on request 1 The current rating is based on an ambient temperature of 45 C and a maximum operating temperature of 90 C, according to IEC Table A.4: Method E: Multi-core cables in free air - For 5 core cables, the values for 3 loaded cores are given. Correction factors for different ambient temperatures are given on page Working capacitance for one-phase asymmetrical or three-phase symmetrical system. The working capacitance of multicore types n>5 depends on the way the wires are connected 18 DRAKA Product information MOG 2010
19 ShipLine Fire Resistant BXOI FR 250 V Armoured halogen free shipboard and offshore cable, fire resistant Application Armoured instrumentation and communication cable for fixed installations on ships and offshore units where cable protection is required. For instrumentation, communication, control, alarm, emergency and critical systems in both EX- and safe areas. Suitable for both indoor and outdoor installations. Properties regarding fire performance Halogen Free - According to IEC ,2 Low smoke - According to IEC ,2 Flame retardant - According to IEC (cat.a) Fire resistant - According to IEC Design standard: IEC Max. temp.: 90 C Nominal voltage: 250V Test voltage: 1.5 kv AC Core identification The pairs have the following number identification: Pair no. 1 core no. 1 and 2 Pair no. 2 core no. 3 and 4 Pair no. 3 core no. 5 and 6 Pair no. 4 etc Construction CODE LETTER Conductor Annealed stranded circular copper Insulation B Mica-tape/crosslinked polyethylene, XLPE Lay up Colour coded cores twisted together and wrapped with polyester tape. The pairs are twisted with different lay length to reduce mutual interference. Pairs are identified by numbered tape. Bedding X No bedding (Additional tapes may be applied) Armour/screen O Tinned copper wire braiding Outer sheath I Flame retardant halogen free thermoplastic compound, SHF1 Outer sheath colour Green product number no. of cores and cross-section (n x mm 2 ) core outer x2x x2x x2x x2x x2x x2x approximate weight (kg/km) Electrical characteristics Type Capacitance approx. (nf/km) Loop inductance approx. (mh/km) Resistance at 20 C max. Single/multi-pair Single-pair Installation recommendations fixed installed Maximum tensile load 8 x D 6 x D 50 N * total cross section s -20 C Minimum installation temperature DRAKA Product information MOG
20 Data cables Overview Data cables RF cables Data cables of the Universal Cable series UC are always in use wherever it is a question of high-speed data transmission in local networks (LAN). Whether Cat5e (Class D), Cat6 (Class E), Cat6a (Class Ea), Cat7 (Class Fa), Class7+ or multimedia - all data cables are in accordance with ISO/IEC 11801, EN and EIA/TIA 568A. On ships, data cables of the UC series are used for standarized and manufacturer-independent networks - Token Ring, Ethernet, ISDN, TPDDI, Fast-Ethernet 100BaseTX, ATM, Gigabit-Ethernet 1000Base T or 10 GbE. The radio-frequency cables are used in transmitter and receiver installations in radio communication as well as in the entire field of commercial radio-frequency technology and electronics. RG cables of the American standard according to MIL-C-17G have become the global standard. They are always applied where high quality is required. On ships, they serve as cables for transmitters and receivers in the radio technology and as connection cables in the navigation technology. Video and Audio cables CATV cables Audio cables are a perfect basis for digital and analogue transmission of audio signals. The digital audio cables are in accordance with the AES/EBU standard. Video cables are used as coaxial cables with a charcteristic impendence of 75Ω for the connection of recording and intermediate amplifiers as well as monitors and cameras. The specified frequency range up to 5000 MHz permits the application of the video cables for serial digital transmission, HDTV and future transmission technology. CATV cables are used in private and commercial trunk lines and TV signal distribution networks. They can be applied from the headend. Drop cables are used in private and commercial TV signal distribution networks and as antenna cables for terrestric and satellite broadcast systems. On ships, CATV cables are applied for example for the transmission of TV channels which are received via satellite TV or terrestric antennas and transmitted to the cabins. In the ship s own television studio for example, audio and video cables are applied in order to enable the transmission from the studio to the cabin. 20 DRAKA Product information MOG 2010
21 Data cables Electrical characteristics of cables Conductor resistance Maximum resistance of copper s according to IEC Class 2 mm 2 Minimum number of strands Circular Conductor Sector-shaped Conductor Ω/km (7) (19) 19 (6) (19) 37 (12) (19) 37 (15) (37) 37 (18) (37) 37 (18) Influence of temperature on the Table 1 resistance Table 2 Temp. C Correction factor Current ratings for continuous load Correction factors for ambient temperatures other than 45 C, according to IEC Table 3 Ambient temp. C Rating factor Short circuit current The maximum permissible short circuit current for different cables is given in the figure aside. This figure is based on the formula: lk = 143 S/ t 100,0 Permissible short circuit current lk = the maximum permissible short circuit current S = the cross-section of the in mm 2 t = the duration of the short circuit in seconds Tk start = 90 C Tk end = 250 C The formula is applicable for an increase in temperature from 90 C at the start to 250 C at the end of the short circuit, when the duration of the short circuit is less than 5 seconds. Short circuit current in ka 10,0 1, Cross-section of the in mm 2 4 0,1 2,5 1,5 0,0 0,1 1,0 10,0 Duration of the short circuit in seconds DRAKA Product information MOG
22 Data cables Electrical characteristics of cables Capacitance of Draka marine cables Working capacitance The actual value of the working capacitance of cables depends on the cable type, the electrical circuit in which the cable functions and, for unscreened and unarmoured cables, the method of installation. The working capacitance of a cable can be calculated by substitution of the partial capacitances in the formulas of table 4 by the value of table 5 and 6. As the theoretical calculation of the working capacitance of multicore cables, 1.5 or 2.5 mm 2, is very complex, no partial capacitances have been indicated. Generally, the value of the working capacitance will, in the case, be less than 100 nf/km. The calculation of the working capacitance Number of cores Cable type Voltage type Working capacitance Table 4 2 unscreened AC C12 screened AC symmetrical AC asymmetrical, screen grounded C12 + ½.C11 C12 + C11 3 unscreened 3 phase AC symmetrical 2 phase AC symmetrical, one core grounded 3.C12 1½.C12 screened 3 phase AC symmetrical 2 phase AC symmetrical, one core grounded 3.C12 + C11 1½.C12 + ½.C11 4 unscreened 3 phase AC, one core grounded CS = 3.C12 + C13 CR,T = 2½.C C13 screened 3 phase AC, one core and screen grounded CS = C C12 + C13 CR,T = C11 + 2½.C C13 CS = working capacitance of phase S CR,T = working capacitance of phases R and T The partial capacitance are defined as follows: C C 12 C C C 23 C 12 C 34 C 13 C 14 C C 11 C 12 C C 22 2 C 12 C C 13 C 11 C 33 C 22 C C 23 C 12 C 34 C 13 C C 14 C 11 C 44 screen screen screen 22 DRAKA Product information MOG 2010
23 Data cables Electrical characteristics of cables Partial capacitances in nf/km TI and TXOI TI in nf/km C12 C13 Number of cores mm Table 5 TXOI in nf/km C11 C12 C13 Number of cores mm Partial capacitances in nf/km TFXI and TIOI TFXI in nf/km C12 C13 Number of cores mm Table 6 TIOI in nf/km C11 C12 C13 Number of cores mm Remark: Measurements in practice have shown that the scatter of partial capacitances of XLPE-insulated cables can amount to 40% DRAKA Product information MOG
24 Draka Kabel B.V. Hamerstraat JV Amsterdam Postbus BA Amsterdam T F
OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
More informationA NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES
A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationCopyright June Nexans
Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical
More informationMultimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS
Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking
More informationMarine Cables General Catalogue
Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes
More informationShip and Offhsore. Approved cables for ship- and offshoreindustry
Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationT E C H N I C A L D A T A for
Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU
More informationCables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :
Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg
More informationArmoured Power and Control Cables to BS7917
1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2
Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded
More informationArmoured Power and Control Cables Fire Resistant
Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity
More informationArmoured Instrumentation Cables to BS6883
Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationInstallation Recommendations
Installation Recommendations Cable pulling recommendations The process of pulling electrical cables on board marine vessels is a relatively standard procedure. Nevertheless, NEXANS would suggest the following
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationDNVGL-CP-0400 Edition December 2015
CLASS PROGRAMME Type approval DNVGL-CP-0400 Edition December 2015 The electronic pdf version of this document, available free of charge from http://www.dnvgl.com, is the officially binding version. FOREWORD
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationMarineLine YOZp 0,6/1 kv
Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame
More informationArmoured Power and Control Cables to BS6883
Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in
More informationData sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft
Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft
Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationList Price w.e.f. 02nd January, 2018
w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable
ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationData sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations
Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded
More informationComplete, innovative cables range for shipbuilding industry
Complete, innovative cables range for shipbuilding industry Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to severe weather conditions Fire Performances
More information15 years of experience
Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationP Low Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high
More informationFLEXIBLE MULTI CORE CABLES
FLEXIBLE MULTI FTM Series...22 MTSV Series...23 TW-T Series...24 PF Series...25 OD Series... 27 HD Series...28 MLG2 Multi Series...30 HO Plus Series...32 HR Series... 34 HRP Series...36 FX Series... 37
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More informationSTANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4
Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked
More informationCables for data transmission in industrial automation
Cables for data transmission in industrial automation The Quality Connection The LEONI Group Cable expertise for the most various industrial markets. LEONI is a leading supplier of cable systems and related
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD IEC 61156-1 Third edition 2007-06 Multicore and symmetrical pair/quad cables for digital communications Part 1: Generic specification Commission Electrotechnique Internationale International
More informationStandard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables
Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240
More informationCABLES AND WIRES
CABLES AND WIRES VOLTEX CATALOGUE 41 3 PVC GENERAL PURPOSE WIRE 1kV House Wire 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC
More informationSUBMERSIBLE PUMP CABLES
12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum
More informationSUPERIOR MARINE CABLE SOLUTIONS
SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables
More informationINTERNATIONAL STANDARD
INTENATIONAL STANDAD IEC 60092-376 Second edition 2003-05 Electrical installations in ships Part 376: Cables for control and instrumentation circuits 150/250 V (300 V) Installations électriques à bord
More informationContent HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...
Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control
More informationRailway products. Edition 2014
Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components
More informationFLAME RETARDANT INSTRUMENTATION CABLE. Application Standard
FLAME RETARDANT INSTRUMENTATION CABLE Designation 150/250V TTY, FA-TTY, 150/250V TTYC, FA-TTYC, 150/250V TTYCY, FA-TTYCY 250V TTYC - Design guide : JIS C 3410(2010) - Flameretardant : IEC 60332-1 : IEC
More informationUNIRAIL D RS485 and BUS cables
UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7
More informationCoaxial Cables Coax Serie. HF Steckverbinder für Mobilfunk-Anwendungen. in Bulk Rings or on Cable Drums
4.3-10 Coax Serie Coaxial Cables HF Steckverbinder für Mobilfunk-Anwendungen in Bulk Rings or on Cable Drums Coaxial Cables In addition to the wide range of coaxial connectors, Telegärtner offers suitable
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More informationSHIPLINK TM to support your performance: cable solutions and services for safety and reliability
SHIPLINK TM to support your performance: cable solutions and services for safety and reliability Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to
More informationREPORT OF PERFORMANCE TIC
REPORT OF PERFORMANCE TIC 1580-13 OBJECT TYPE Three-core power cable 18/30(36) kv, 3x500 mm2, 2XWY(P)-FR XLPE Rated voltage, U 0/U (U m) 18/30 (36) kv Conductor material Cu Conductor cross-section 3x500
More informationCCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations
CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line
More informationEC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s
EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)
More information1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)
WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,
More informationIEC Standard Caledonian Offshore & Marine Cables
Power Copper s According to IEC 60228 Tinned conductors Cross section cl.2 cl.5 Cross section cl.2 cl.5 mm² Ohm/km Ohm/km mm² Ohm/km Ohm/km 1.0 18.2 20 70 0.270 0.277 1.5 12.2 13.7 95 0.195 0.210 2.5 7.56
More informationK20 & L120 LSZH Armoured F/FTP Cat6 Cables
K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE
More informationNotes 3 Explanatory Information 4-10
Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum
More informationData sheet OpDAT breakout cable 24x1 OM4 - bend insensitive
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More informationCores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.
()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationMULTIMEDIA CABLE H6091ZHB
CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationCY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED
PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned
More informationSINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V
LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable
More informationINDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS
INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C
More informationABOUT US ABOUT US 1 CRANE CABLES
ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its
More informationThe Quality Connection. Cable and Systems for Rolling Stock Business Unit Rolling Stock
The Quality Connection Cable and Systems for Rolling Stock Business Unit Rolling Stock Consulting and Sales Cable solutions Phone +41 (0)62-288-8356 Fax +41 (0)62-288-8383 System solutions Phone +49 (0)9172-6844-11
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More informationMULTIMEDIA & DATA TRANSMISSION
NEXANS, every c a b l e t h a t m a k e s a t r a i n r o l l Whoever you are, rolling stock OEM, subsystem supplier or operator, Nexans provides everything from energy & telecom cable to integrated cabling
More information11-SDMS-03 REV. 02 SPECIFICATIONS FOR
11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice
More informationCAT 5e UTP Cable: NETSET BOX [305m], indoor
Code: E08_05 CAT 5e UTP Cable: NETSET BOX [05m], indoor NETSET BOX UTP 5e Ethernet cable far exceeds the requirements for Category 5e twisted pair cables. View of the cable box - inside 05m of the cable.
More informationWire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits
Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a
More informationHow to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)
S P E C I A L I S T C A B L E S U P P L I E R S How to order Online / acatalog By phone + (44) 1628 850024 By fax + (44) 1628 648068 By email info@csecables.com Our hours Monday to Friday, 8am-5.30pm Payment
More informationkv: medium voltage reeling cable with fibreoptics
PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy
More informationThe Quality Connection. ICON Product Guide
The Quality Connection ICON Product Guide 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for special applications Instrumentation-
More informationDLO Flexible Power Cable
Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C
More informationScreened servo cable with PUR outer sheath for highly dynamic power chain application - certified
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and
More informationSelection table for flat & ribbon cables
Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON
More informationCables for Data Transmission in Industrial Automation. Fieldbus Cables Copper Cables Fibre Optic Cables
Cables for Data Transmission in Industrial Automation Fieldbus Cables Copper Cables Fibre Optic Cables 2 KERPEN GmbH & Co. KG 2005 2.2006 Printing errors excepted. Subject to alteration. Contents Seite
More informationBENDING RADIUS. DIAMETER TOLERANCE Cable outer diameter, mm. Tolerance CORE IDENTIFICATION TECHNICAL INFORMATION 8/2010
BENDING RADIUS Recommended minimum bending radius, ( R ) : Radius (R) Outer diameter (D) LKM-HF During installation R = 6x D < mm LKMM-HF During installation R = 6x D < mm LKM-FRHF During installation
More informationCaledonian. VG Series. Caledonian Navy Cables.
Caledonian Caledonian Navy Cables www.addison-cables.com Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationServo Cable Selection
Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)
More informationSPEC 44. Wire and cable
SPEC 44 Wire and cable Applications SPEC 44 wire has a dual wall construction which combines the outstanding physical and electrical characteristics of radiation crosslinked polyalkene with the excellent
More informationIndustrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.
More informationH155A02. Product Description. Product Specifications. Technical Specifications. Application. Bend Radius. CCB-Sub-Crush Resistance.
H155A02 Part Number: H155A02 COAX RF H155 FRNC Product Description COAX RF H155 FRNC Product Specifications Application Application 1: Application 2: 50 Ohm low loss coaxial transmission cable designed
More informationDetailed Specifications & Technical Data
RFP Specification #17-11125-C, Exhibit 2 Programmable Light Poles for BART Plaza ENGLISH MEASUREMENT VERSION 1502SB Multi-Conductor - Multimedia Control Cable For more Information please call 1-800-Belden1
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationCategory 6 A F/FTP Euroclass C ca Cables
Category 6 A F/FTP Euroclass C ca s Datasheet: GD103266v2 APPLICATION The Brand-Rex AC6F/FTP C ca cables are compliant with the European Construction Products Regulation, achieving Euroclass level C ca
More informationSY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID
ISSUE DATE: 05/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11:2011 Plain Annealed Flexible Copper Conductors / PVC Insulated / PVC Bedding / GSWB (Galvanised Steel Wire Braid) / PVC Sheathed.
More informationOpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram
Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or
More informationInstrumentation Cable PLTC/ITC and TC Types
Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More information