CABLES AND WIRES
|
|
- Martha Wilkins
- 5 years ago
- Views:
Transcription
1 CABLES AND WIRES VOLTEX CATALOGUE 41 3
2 PVC GENERAL PURPOSE WIRE 1kV House Wire 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with PVC and skin coloured in plain colours to SANS 1411 Part 2. Cable is manufactured to SANS 1507 Part 3. Installation Information For the wiring of Industrial Buildings, Housing, Control Panels and Light Fittings. Technical Data Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Core Identification : Complete range of colours Packaging : 100m shrink-wrapped /500m reels Nominal Stranding No. x Diameter Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 600/1000 V 1 7/0,42 3, ,1 43 1,7 1,5 7/0,53 3, ,1 29 2,2 2,5 7/0,66 3,6 27 7, ,2 4 7/0,86 4,5 36 4, ,2 6 7/1,04 5,0 45 3,08 7,4 7,0 10 7/1,35 6,0 61 1,83 4,4 11,1 16 7/1,67 6,9 78 1,15 2,8 16, /1,38 8, ,73 1,7 25, /1,62 9, ,52 1,3 34, /1,88 11, ,39 0,93 47, /2,28 12, ,27 0,65 66, /2,50 15, ,19 0,48 97, /2,03 17, ,15 0,38 120, /2,28 19, ,12 0,32 147, /2,50 22, ,10 0,26 182,2 Rating calculated for 1kV cable. Rating based on two touching cables installed in a duct. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Compacted Conductors. Code Table Colours (mm 2 ) Black Blue Brown Green Yellow Grey Mustard Orange Pink Purple Red White Yellow 1 F232 F233 F234 F235 F236 - F237 F238 F239 F240 F241 F242 1,5 F245 F246 F247 F249 F250 F251 F252 F253 F254 F256 F258 F259 2,5 F262 F263 F264 F266 F267 - F268 F269 F270 F272 F274 F275 4 F278 F279 F280 F F283 F284 F285 F287 F289 F290 6 F293 F294 - F F298 F F303 F304 - F F308 F F313 F314 - F316 - F F318 F320 F F323 F324 - F F327 F F330 F331 - F F335 F F340 F341 - F F344 F F349 F350 - F F354 F F356 F F F359 F F F F F F F F For items marked with a dash (-) please enquire at branch or reference website VOLTEX CATALOGUE
3 SURFIX CABLE 300/500V Cable Description Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare tinned copper earth wire in contact with a longitudinal aluminium/polyethylene laminate, UV stable PVC sheathed to SANS 1411 Part 2. Installation Information Complies with SANS Code of Practice for wiring of Premises Section 6: Surface wiring Under plaster wiring Wiring in hollow walls Wiring in roof spaces The cable shall not be buried direct in concrete or in screed. Joints in the wiring should be in boxes only. Technical Data Properties UV Stable Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 300/500V Sheath Identification : White or Black Core Identification : 2 Core - Red & Black, 3 Core - Red, Yellow, Blue, 4 Core - Red, Yellow, Blue, Black Packaging : 100m shrink-wrapped coils : Available on 500 and 1000m wooden drums on request (depending on size) Phase Earth Phase Earth Electrical Properties Conductor Resistance (dc at 20ºC) Current Rating Volt Drop 1 Sec Short Circuit Rating Overall Diameter Physical Properties Cable Mass (mm 2 ) (Ω/km) (A) (mv/a/m) (ka) (mm) (kg/100m) 2 Core 1,5 1 12,1 18, ,14 7,8 10,6 2,5 1,5 7,41 12, ,24 8,8 14,4 4 1,5 4,61 12, ,38 10,1 20,8 6 2,5 3,08 7, ,3 0,58 11,3 25,7 3 Core 1,5 1 12,1 18, ,14 8,0 10,9 2,5 1,5 7,41 12, ,24 9,3 15,7 4 1,5 4,61 12,2 27 9,5 0,38 10,8 21,0 6 2,5 3,08 7, ,4 0,58 12,0 28,7 4 Core 1,5 1 12,1 18, ,14 8,7 13,3 2,5 1,5 7,41 12, ,24 10,2 19,3 4 1,5 4,61 12,2 27 9,5 0,38 11,8 26,5 6 2,5 3,08 7, ,4 0,58 12,8 33,5 Conductors larger than 2,5mm² are usually stranded. Maximum conductor temperature 70 C, and installed as per installation Method 3 of SANS Core - Volt drop is phase to Neutral (i.e. Single-phase). 3 and 4 Core - Volt drop is phase-to-phase. (i.e. Three phase AC). Code Table Black Surfix is a trademark of Aberdare Cables, a member of the Powertech Group. Other colours available on request. Minimum quantities apply. Colours (mm 2 ) 2 Core 3 Core 4 Core 2 Core 3 Core 4 Core 1,5 F598 F603 F608 F600 F605 F609 2,5 F614 F619 F623 F616 F620 F624 4 F627 F631 F635 F628 F632 F636 6 F639 F641 F643 F640 F642 F F F For items marked with a dash (-) please enquire at branch or reference website. White VOLTEX CATALOGUE 43 3
4 FLAT TWIN AND EARTH CABLE 300/500V Cable Description Copper conductors to SANS 1411 Part 1, PVC insulated to SANS 1411 Part 2, laid up with a bare copper earth-continuity-conductor between them, UV stable PVC sheathed to SANS 1411 Part 2. Installation Information Complies with SANS 10142/2001 Code of Practice for the wiring of Premises Section 6, Clause 6.3.6: Surface wiring Under plaster wiring Roof access wiring Wiring in hollow walls Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 300/500V Sheath Identification : White or Black Core Identification : 2 Core - Red & Black, 3 Core - Red, Yellow, Blue Packaging : 100m shrink-wrapped coils The cable should not be buried direct in concrete or in screed. Joints in the wiring should be in boxes only. Technical Data Phase Earth Phase Earth Electrical Properties Conductor Resistance (dc at 20ºC) Current Rating Volt Drop 1 Sec Short Circuit Rating Conductors larger than 2,5mm² are usually stranded. Maximum conductor temperature 70 C, and installed as per installation Method 3 of SANS Core - Volt drop is phase to Neutral (i.e. Single-phase). 3 and 4 Core - Volt drop is phase-to-phase. (i.e. Three phase AC). Overall Diameter Physical Properties Cable Mass (mm 2 ) (Ω/km) (A) (mv/a/m) (ka) (mm) (kg/100m) 2 Core 1,5 1 12,1 18, ,14 8,7 x 4,7 8,7 2,5 1,5 7,4 12, ,24 10,3 x 5,5 12,8 4 1,5 4,61 12, ,38 11,9 x 6,4 17,5 6 2,5 3,08 7, ,3 0,58 13,4 x 7,0 23, ,83 4, ,4 0,96 16,5 x 8,3 36,1 3 Core (Trip) ,2 18, ,11 4,4 x 10,4 8,9 1,5 1 12,1 18, ,14 4,8 x 10,5 9,9 2,5 1,5 7,4 12, ,24 5,5 x 12,3 14,1 Code Table Black Colours (mm 2 ) 2 Core 3 Core 2 Core 3 Core 1 F663 - F665 F659 1,5 F667 - F669 F660 2,5 F671 - F672 F661 4 F674 - F F F678 - F F681 - White For items marked with a dash (-) please enquire at branch or reference website VOLTEX CATALOGUE
5 CABTYRE CABLE Flexible Wiring 300/300V and 300/500V Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated and colour coded with general purpose flexible grade PVC to SANS 1411 Part 2. Cores are twisted together and sheathed with a flexible grade PVC. Installation Information For supplying power to all types of electrical, domestic and industrial appliances and equipment such as: Power Tools Electric Lawnmowers Kitchen Appliances Technical Data Extension Leads Multi Plug Extensions Small Industrial Machinery Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Voltage Rating : Light Duty (LD) 300/300V and Normal Duty (ND) 300/500V Sheath Identification : White, Black or Grey Core Identification : 2 Core - Blue & Brown, 3 Core - Blue, Brown & Yellow/Green, 4 Core - Blue, Brown, Black & Yellow/Green, 5 Core - Blue, Black, Brown, Yellow/Green, Violet, 7 Core - Blue, Brown, Black,Yellow/ Green, Violet, Pink, Orange Packaging : 100m shrink-wrapped coils/500m and 1000m lengths available on request Number of Cores Nominal Stranding No. x diameter Overall Diameter Conductor Resistance at 20ºC Maximum Current Volt Drop Rating 1OI 3OI 1OI 3OI Cable Mass (mm 2 ) (mm) (Ω/km) (A) (mv/a/m) (kg/100m) Light Duty 300/300V 0,5 2 5,2 3 5,5 4,7 15/0, ,0 5,5 5 6,6 6,7 0, /0,2 6, ,5 0,75 1 1,5 2, ,2 Normal Duty 300/500V 3 7,0 6,7 4 23/0,2 7, ,8 5 8,2 9,9 7 8,7 12,6 2 6,6 3 7,0 7,6 4 30/0,2 8,0 19, ,8 5 8,6 11,6 7 9,3 14,8 2 7,8 3 8,3 10,8 4 44/0,2 9,3 13, ,5 5 10,0 16,2 7 10,9 20,7 2 9,6 3 10,3 16,8 4 72/0,2 11,9 7, ,8 5 12,2 24,2 7 13,2 31,3 2 11,0 3 11,4 25,0 112/0,2 4, ,5 32,0 5 14,1 33,9 3,9 5,2 6,3 8,4 13,5 19,0 Current Rating based on ambient temperature of 30ºC. Maximum Conductor temperature is 70 C. Code Table Colours Black Grey White (mm 2 ) 2 Core 3 Core 4 Core 5 Core 7 Core 2 Core 3 Core 4 Core 5 Core 7 Core 2 Core 3 Core 4 Core 5 Core 7 Core 0,5 F83 F87 F91 F F F84 F89 F92 F1519-0,75 F95 F100 F106 F108 F110 F3266 F F96 F107 F107 F109-1 F113 F119 F123 F126 F128 F114 F120 F F115 F121 F124 F1522 F1523 1,5 F131 F137 F143 F148 F153 - F138 F1525 F149 - F132 F139 F144 F150 F154 2,5 F155 F161 F166 F171 F173 - F162 F F156 F163 F168 F172 F174 4 F175 F176 F178 F181 F182 - F1530 F F1529 F177 F For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 45 3
6 AUDIO CORD CABLE (RIPCORD) Flexible Wiring Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. 2 Core insulated with general purpose flexible grade PVC to SANS 1411 Part 2. Installation Information For the wiring of all types of: Intercoms Alarm Systems Audio and Visual Equipment Packaging : 100m shrink-wrapped coils Technical Data Nominal Stranding No. x Diameter Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 0,2 7/0,2 1,6 x 3, ,95 0,4 11/0,2 2,1 x 4,2 2 48,8 98 1,6 0,5 15/0,2 2,5 x 5, ,2 0,75 23/0,2 2,7 x 5, ,8 1,00 30/0,2 2,9 x 5, ,5 46 3,6 1,5 44/0,2 3,2 x 6, ,3 32 4,3 2,5 72/0,2 3,9 x 7,9 25 7, , /0,2 4,7 x 9,4 32 4, ,9 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Code Table Colours (mm 2 ) Black Brown Clear Grey Red Black White 0,2 - F1322 F F520 0,5 F524 F525 F526 F1326 F528 F527 0,75 F530 F1327 F531 F F532 1 F533 F534 F F536 1,5 F F538 F539 2, F540 F F541 - For items marked with a dash (-) please enquire at branch or reference website VOLTEX CATALOGUE
7 SINGLE CORE FLEXIBLE CABLE Single Core Flexible Cable 300/500V and 600/1000V Cable Description High conductivity bunched plain flexible copper conductors to SANS 1411 Part 1. Insulated with general purpose flexible grade PVC in all colours to SANS 1411 Part 2. Installation Information For the wiring of all types of: Control panels Light fittings Communication panels Appliances Technical Data Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 300 / 500V and 600/1000V Core Identification : Blue, Black, Brown, Yellow/Green, Orange, Pink, Violet, Grey, White & Red Packaging : 100m shrink wrapped coils : 500m lengths available on request Nominal Stranding No. x Diameter Cable Diameter Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Rating for 2 wires only. Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/100m) 600/1000V 0,5 15/0,2 2, ,3 1,1 0,75 23/0,2 2, ,2 1,3 1 30/0,2 3, ,5 46,7 1,6 1,5 44/0,2 3, ,3 31,8 2,2 2,5 72/0,2 3,7 26 7,98 19,1 3, /0,2 4,8 35 4,95 11,8 4, /0,2 5,3 43 3,30 7,9 7, /0,2 9,1 58 1,91 4,6 11, /0,2 10,0 75 1,21 2,9 16, /0,21 12, ,78 1,9 27, /0,21 14, ,55 1,3 35,8 Code Table Colours (mm 2 ) Black Blue Brown Green Yellow Grey Orange Pink Violet Red White Yellow 0,5 F433 F434 F435 F436 F437 F440 F439 F442 F441 F443 F444 0,75 F445 F446 F447 F448 F449 F451 F450 F453 F452 F454 F455 1 F456 F457 F458 F459 F461 F463 F462 F465 F464 F466 F467 1,5 F468 F469 F470 F471 F472 F474 F473 F476 F475 F477 F478 2,5 F489 F490 F491 F492 F493 F1346 F1343 F1345 F494 F495 F496 4 F497 F498 F499 F500 F501 F F1347 F502 F503 F F504 F505 F506 F507 F F509 - F F479 F480 - F F482 F F484 F485 - F F487 F F1350 F F1349 F For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 47 3
8 POWER PANEL FLEX CABLE 300/500V and 600/1000V Cable Description Single core flexible copper conductors to SANS 1411 Part 1, Insulated with general purpose flexible grade PVC and sheathed with a flexible grade waterproof PVC/Nitrile. Installation Information A flexible power cable where flexibility is needed in equipment such as: LV transformer connections Motor control centres General wiring applications Distribution boards Technical Data Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 300/500 V and 600/1000V Core Identification : Red, Black, Blue, Yellow, Green and Grey Packaging : 100m shrink-wrapped coils : 500m lengths available on request Conductor Size Conductor Diameter Cable Diameter Impedance at 70 C Current ratings are based on cable installed in a cubicle, and may vary depending on other applications. Assumed ambient air temperature is 30 C. Maximum conductor temperature is 70 C. Derating of maximum current for other ambient temperatures - use rating factor X as given below: Ambient temperature, ºC : Rating factor, X : 1,04 1,00 0,95 0,91 0,85 Fault rating : 115A/mm² (1 Second) Volt Drop (mv/a/m) Continuous Current Rating (A) Cable Mass (mm 2 ) (mm) (Ω/km) 1OI 3OI 1OI 3OI (kg/100m) 16 5,2 10, ,8 2, , ,1 13,5 0,933 1,7 1, , ,5 15,3 0,663 1,3 1, , ,4 18,4 0,462 0,9 0, , ,6 21,2 0,326 0,7 0, , ,1 24,1 0,247 0,5 0, , ,6 25,6 0,193 0,4 0, , ,30 27,7 0,16 0,3 0, , ,00 30,8 0,14 0,3 0, ,00 Code Table Colours (mm 2 ) 16 Green F Blue F Grey F Red F Brown F Yellow F Black F Black F VOLTEX CATALOGUE
9 SILICONE CABTYRE CABLE Flexible Cable 300/500V Cable Description High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone Rubber Type RD7 and sheathed with Silicone Rubber Type RS8 to SANS 1574 Part 4 Type R7, H05SS-F. Installation Information For the wiring of all types of: Stoves Electrical Motors and Pumps Fluorescent Lights All other types of High Temperature Appliances Properties Specification : SANS Pt4 Temperature : -50 C to 150 C (Capable of current rating at 180 C if there are no limits imposed by environmental conditions) Voltage Rating : 300/500V Core Identification : 3 Core - Blue, Brown and Yellow/Green, 4 Core - Blue, Brown, Black and Yellow/Green : Insulation and sheath is halogen free and has a low smoke emission : Limiting Oxygen Index is 24% Packaging : 100m shrink - wrapped coils Technical Data Number of Cores Nominal Stranding No. x diameter Cable Diameter Conductor AC Resistance at 150 C Current Rating Cable Mass (mm 2 ) (kg/km) (mm) (Ω/km) (A) (kg/km) 0, /0,2 7,6 40, /0,2 9,9 30, ,5 2, , /0,25 20, , , /0,25 12, , , /0,3 7, ,8 345 Assumed ambient temperature is 80 C. Maximum Conductor temperature is 150 C. Derating of Current Rating for other Ambient Temperatures. Ambient Temperature, C : Rating Factor, X : 1,22 1,12 1 0,87 0,73 0,57 0,37 Code Table Colour RED (mm 2 ) Core 3 Core 4 0,75 F2261 F1270 1,00 F3342 F9416 1,50 F185 F2265 2,50 F188 F2266 4,00 F VOLTEX CATALOGUE 49 3
10 SILICONE SINGLE CORE CABLE Flexible Cable 300/500V and 600/1000V Cable Description High conductivity tinned stranded, flexible copper conductors to SANS 1411 Part 1. Insulated with Silicone Rubber Type RD7 to SABS 1574 Part 4, H05SS-F & HIS-F in various colours. Installation Information For the wiring of all types of: Control Panels Appliances Light Fittings All High Temperature Applications Technical Data Properties Specification : SANS 1574 Pt4 Temperature : -50 C to 150 C (Capable of current rating at 180 C if there are no limits imposed by environmental conditions) Voltage Rating : 300/500V (0,05mm 2-16mm 2 ) and 600/1000V (0,5mm 2-95mm 2 ) Core Identification : Red, Black, Blue, Brown, Green/Yellow and White (Other colours available on request) : Insulation is halogen free and has a low smoke emission. Limiting Oxygen Index is 24% Packaging : Shrink - wrapped - Coils 100m 0,5-35mm 2 - Reels 100m 50 mm 2 Conductor AC Current Rating Nominal Cable Diameter Resistance Single Cable Cable in Trefoil Cable Mass No. x diameter Stranding 300/500V 600/1000V 180 C 180 C 300/500V 600/1000V (mm 2 ) (mm) (Ω/km) (A) (kg/km) 0,5 16/0,2 2,2 2,6 65, ,8 10,7 0,75 24/0,2 2,4 2,8 43, ,7 13,4 1 32/0,2 2,5 3,0 32, ,3 18,1 1,5 30/0,25 3,2 3,3 22, ,4 23,9 2,5 50/0,25 3,9 3,7 13, ,7 37,4 4 56/0,3 4,7 4,8 8, ,4 54,4 6 81/0,3 5,2 5,3 5, ,2 75, /0,4 6,6 6,3 3, ,8 118, /0,4 7,6 7,2 2, ,7 180, /0,4 9,5 1, /0,4 10,9 0, /0,4 N/A 13,2 0, N/A /0,5 14,4 0, /0,5 17,3 0, Capable of continuous current rating at 180 C and 250 C if there are no limits imposed by environmental conditions. Ambient temperature is 80 C. Maximum Conductor temperature is 150 C. Derating of Current Rating for other Ambient Temperatures. Ambient Temperature, C : Rating Factor, X : 1,22 1,12 1 0,87 0,73 0,57 0,37 Code Table Colours Black Blue Brown Green Grey Orange Red Violet White (mm 2 ) 0,5 F1256 F F F F1260 0,75 F1261 F1262 F1263 F1264 F F F F2468 F2469 F1460 F1461 F F F1463 1,5 F549 F551 F552 F1110 F555 - F557 F1272 F558 2,5 F559 F561 F562 F1112 F565 F1467 F566 F1468 F F569 F570 - F916 F F572 F1483 F573 6 F574 F575 - F1491 F F576 F1493 F F578 F F1277 F F579 F1279 F F1454 F F F F F F F F F F F F F F F For items marked with a dash (-) please enquire at branch or reference website VOLTEX CATALOGUE
11 SUBMERSIBLE PUMP CABLE 3 and 4 Core 600/1000V Cable Description High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1. Cores insulated and bedded with Flexible PVC Grade. Final protection is given by a flexible PVC outer sheath. Installation Information Power supply of mobile and portable submersible pumps as used in: Quarries Farms Cleaning and Sewerage extraction plants De-watering Boreholes Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Insulation & Sheath : Flexible grade waterproof PVC Voltage Rating : 600/1000V Sheath Identification : 3 Core - Blue, 4 Core - Green Core Identification : 3 Core - Red, Yellow, Blue, 4 Core - Red, Yellow, Blue, Black Packaging : Available on 500m wooden drums Technical Data Minimum Bending Radius Cable Diameter Current Rating Conductor Resistance at 20ºC Maximum 1OI Volt Drop 3OI Cable Mass (mm 2 ) (mm) (mm) (A) (Ω/km) (mv/a/m) (kg/m) 3 Core (Blue) 1,5 x , , ,15 2,5 x ,7 20 7, ,2 4 x ,5 30 4, ,5 0,3 6 x ,1 35 3,30 7,3 6,4 0,5 10 x ,6 50 1,91 4,3 3,8 0,6 16 x ,1 65 1,21 2,8 2,4 0,8 4 Core (Green) 1,5 x , , ,2 2,5 x ,8 20 7, ,25 4 x ,6 30 4, ,5 0,35 6 x ,5 35 3,30 7,3 6,4 0,5 10 x ,2 50 1,91 4,3 3,8 0,7 16 x ,0 65 1,21 2,8 2,4 1 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. Code Table Colours Blue Green (mm 2 ) 3 Core 4 Core 1,5 x 3 F1510-1,5 x 4 F1512-2,5 x 3 F584-2,5 x 4 F586 F x 3 F588-4 x 4 F590 F x 3 F x 4 F7922 F x 3 F x 4 - F x 3 F For items marked with a dash (-) please enquire at branch or reference website. VOLTEX CATALOGUE 51 3
12 NITRILE TRAILING CABLE Flexible PVC - 4 Core 600/1000V Cable Description High conductivity bunch plain flexible copper conductors to SANS 1411 Part 1. Cores insulated and bedded with Flexible PVC. Flexible Grade PVC / Nitrile outer sheath. Installation Information Power supply of mobile and stationary industrial machinery. Applications that require medium duty abrasion and where oil and water resistance is required. Technical Data Properties Specifications : SANS 1574 Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Sheath Identification : PVC/Nitrile - Orange Core Identification : Red, Yellow, Blue, Black Packaging : Available on 500m wooden drums Overall Diameter Current Rating Conductor Resistance at 20 C Maximum 1OI Volt Drop Cable Mass (mm 2 ) (mm) (A) (Ω/km) (mv/a/m) (kg/m) 1,5 x ,3 25 0,2 F3267 2,5 x , ,3 F653 4 x ,96 9,5 0,4 F654 6 x ,30 6,4 0,5 F x ,91 3,8 0,7 F x ,21 2,4 1 F x 4 26,2 95 0,78 0,87 1,4 F658 Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C VOLTEX CATALOGUE
13 GENERAL WELDING CABLE EPM/CM or EPM/CR 100V Cable Description Single core flexible copper conductors to SANS 1411 Part 1, EPM (Ethylene-propylene monomer) insulated, CM (Chloronated Polyethylene) or CR (Polychloropene) sheathed, heavy duty welding cables. Installation Information Heavy duty welding for: Indoor and outdoor electric welding equipment. Technical Data Properties Specification : SANS 1576 Voltage Rating :100V AC or DC to earth for welding applications Core Identification : EPM/CM - Outer CM sheath is coloured : EPM/CP - EPM insulation is coloured and CR sheath is black Packaging : 100m shrink - wrapped coils Physical Properties Conductor Dimensions Colour Conductor Size Maximum Diameter of Wires Diameter Maximum Resistance of Untinned Conductor at 20 C Nominal Thickness of Insulation Overall Diameter Cable Mass (mm 2 ) (mm) (Ω/km) (mm) (kg/m) Green 16 0,31 5,2 1,210 2,0 9,2 0,25 Blue 25 0,31 7,1 0,780 2,0 11,1 0,35 Grey 35 0,31 8,5 0,554 2,0 12,5 0,45 Red 50 0,31 10,4 0,386 2,2 14,8 0,60 Brown 70 0,31 11,6 0,272 2,4 16,4 0,75 Yellow 95 0,31 14,1 0,206 2,6 19,3 1,10 Black 120 0,51 15,6 0,161 2,8 21,2 1,40 Electrical Properties Size Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 85 C. Assumed duty cycle period 5 minutes. Derating of maximum current for other ambient temperatures. use rating factor X as given below: Class of Welding Automatic Manual Very Semi-automatic Intermittent Maximum Current Rating (A) for Duty Cycles of: Ambient Temperature, C : Rating Factor, X : 1,04 1,00 0, ,85 DC Voltage Drop (mm 2 ) 100% 85% 60% 30% 20% mv/a/m , , , , , , ,3 Code Table Colours (mm 2 ) 16 Green F Blue F Grey F Red F Brown F Yellow F Black F Black F2465 VOLTEX CATALOGUE 53 3
14 HO7RN-F FLEXIBLE GENERAL PURPOSE TRAILING CABLE Cable Construction Flexible copper conductors (Class 5 Annealed Copper Conductors), EPR based rubber insulated, cores laid up and Neoprene Rubber sheathed. Application This cable is suitable for use in dry, humid or wet environments and in open air. This cable is suitable for medium mechanical stress, in workshops and general industry. It is mostly used on industrial machinery, however is also suitable for use on home tools, electric motors and portable generators. HO7RN-F cable is highly suitable as a general purpose cable for temporary power supply, but also for use when installing cable in limited space or for use with small bending radius. Neoprene (CR) provides many of the attributes of natural rubber in jacketing but it does offer significantly better heat, ozone-corona, weather, chemical, oil and flame resistance. The mechanical characteristics of Neoprene makes it highly suited to a diverse range of applications including jacketing for all types of heavy duty and extra-heavy-duty mining cables. Max continuous operating conductor temperature in normal use: +60ºC (in every case of mobile installation) +85ºC (fixed protected installation) +200ºC (in short circuit) Permissible current rating is measured for an ambient temperature of 30ºC and a maximum operating and conductor temperature of 85ºC. Single Core HO7RN-F 300/500V Size Volt Drop mv/a/m Nominal Outer Diameter Cable Weight Resistance (Untinned) Current Carrying Capacity (Air at 30º) (mm 2 ) 1OI 3OI (mm) (kg/km) Ω/km (A) Product Code 1,5 23,30 20,18 5, , ,5 14,00 12,12 6, , ,70 7,53 7, , ,90 5,11 8, , ,40 2,94 10, , ,20 1,91 11, , F ,40 1,21 13, , F ,04 0,90 15, , F ,75 0,65 17, , F ,56 0,48 20, , F ,50 0,40 22, , F ,36 0,31 24, , F ,31 0,27 26, , F ,28 0,24 28, , F ,23 0,20 32, , F ,20 0,17 36, , F ,18 0,16 42, , ,16 0,14 45, , F1513 For items marked with a dash (-) please enquire at branch or reference website VOLTEX CATALOGUE
15 HO7RN-F FLEXIBLE GENERAL PURPOSE TRAILING CABLE Multicore HO7RN-F 450/750V Size Cores Nominal Outer Diameter Mass Max Resistance at 20ºC Volt Drop (mv/a/m) Current Carrying Capacity (Air at 30ºC) (mm 2 ) (mm) (kg/km) Ω/km 3OI (A) 1,5 2, Product Code 2 9, F , , , ,18 21 F , F , F , F , , , , , , F , , , ,9500 7, , F , F , , F , ,3000 5, , F , F , , F1408 1,9100 2, , F , F , , ,2100 1, F , F , F , , F1414 0,7800 1, , F , F , F1417 0,5540 0, , F , F1420 0,3860 0, , F , ,2720 0, , F , ,2060 0, , F , ,1610 0, , F , ,1290 0, , F , ,1060 0, , F , ,0801 0, , F , ,0641 0, , For items marked with a dash (-) please enquire at branch or reference website. Additional core sizes are available on request. VOLTEX CATALOGUE 55 3
16 BARE COPPER Earth Wiring Cable Cable Description High conductivity plain soft stranded copper conductors to SANS Installation Information For the wiring of earthing circuits where general house wiring is used. 1,5mm² - Amps at 30 C = 20 2,5mm² - Amps at 30 C = 27 4,00mm² - Amps at 30 C = 37 6,00mm² - Amps at 30 C = 70 Technical Data for Typical Guideline Values Properties Specifications : SANS Temperature Range : -10 C to 70 C Sheath Identification : Copper Packaging : 1,5mm² - 6mm², 5kg & 25kg coils : 10mm² - 16mm², 25kg & 500kg wooden drums : 25mm² - 240mm² & 500kg wooden drums Conductor Size Nominal Stranding Metres (mm²) (No. x Diameter) (m/kg) 1,5 7/0,53 72,22 2,5 7/0,66 46,62 4 7/0,85 27,46 6 7/1,04 18, /1,35 11, /1,67 7, /1,38* 4, /1,62* 3, /1,88* 2, /2,28* 1, /2,50 1, /2,03 0, /2,28 0, /2,50 0, /2,98 0,450 Compacted conductors. Example Customer Enquiry: 180m of 70mm² Copper Earth Wire. 1kg of 70mm² Copper is therefore = 1,56m. So 180m divided by 1,56 = 115,38kg say 115kg. Kg Metre (mm 2 ) 1,5 F216 F4202 2,5 F217 F797 4 F218 F786 6 F219 F F220 F F221 F F222 F F223 F F224 F F225 F F226 F F227 F F228 F F229 F VOLTEX CATALOGUE
17 BELLS AND MAINS LOW VOLTAGE PVC CABLE Useful Technical Data Flamosafe Range of Fire Preformance Electric Cables Description FR (Flame Retardant) Red Stripe cables are designed to reduce the spread of fire along a cable tray or duct. However, when these cables burn, they give off large quantities of toxic gases and smoke. (FYRGARD ) (Common Type) LHFR (Low Halogen) Blue Stripe cables have specially formulated PVC that reduces the emission of hydro-chloric acid during burning of the cables. (LOHAL ) NHLSFR (Non Halogen) White Stripe cables are designed to reduce flame propagation and smoke in those instances where a fire may develop. By replacing the standard PVC with XLPE insulation and EVA bedding and outer sheath, no HCI gases will be liberated during the burning of the cables. (LOTOX ) Flamosafe, Fyrgard, Lohal and Lotox are registered trademarks of Aberdare Cables, a member of the Powertech Group. VOLTEX CATALOGUE 57 3
18 BELLS AND MAINS LOW VOLTAGE PVC CABLE PVC PVC SWA PVC (FR) 600/1000V Electrical and physical properties of 3 and 4 core PVC insulated PVC bedded *SWA PVC sheathed 600/1000V cables with aluminium or copper conductors and manufactured to SANS * Where the armouring of cable is used as the earth continuity path, it may be necessary to replace some of the steel wires with tinned copper wires (ECC) or to use a supplementary earth continuity conductor. Installation Information Residential applications, factories, office blocks and shopping centres. Technical Data D1 D2 d D1 = Diameter over bedding sheath d = Diameter of armour wire D2 = Diameter over outer sheath Copper Conductors Size Current Rating Electrical Properties Impedance Volt Drop 1 Sec Short Circuit Rating Physical Properties Nominal Diameters D1 d D2 Mass Ground Ducts Air 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core (mm²) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) 1, ,48 25,080 0,17 8,51 9,33 1,25 1,25 14,13 14, , ,87 15,363 0,28 9,61 10,56 1,25 1,25 15,23 16, ,52 9,561 0,46 11,40 12,57 1,25 1,25 17,02 18, ,69 6,391 0,69 12,58 13,90 1,25 1,25 18,40 19, ,19 3,793 1,15 14,59 16,14 1,25 1,25 20,41 21, ,38 2,390 1,84 16,55 19,18 1,25 1,25 22,37 25, ,8749 1,515 2,87 19,46 21,34 1,60 1,60 26,46 28, ,6335 1,097 4,02 20,89 23,97 1,60 1,60 27,89 31, ,4718 0,817 5,75 24,26 28,14 1,60 1,60 31,46 36, ,3325 0,576 8,05 27,07 31,29 2,00 2,00 35,47 40, ,2460 0,427 10,92 31,19 35,82 2,00 2,00 39,99 44, ,2012 0,348 13,80 33,38 38,10 2,00 2,00 42,18 47, ,1698 0,294 17,25 36,68 42,05 2,00 2,00 45,98 52, ,1445 0,250 21,27 40,82 46,75 2,50 2,50 51,12 57, ,1220 0,211 27,60 46,43 53,06 2,50 2,50 57,13 64, ,1090 0,189 34,50 51,10 58,53 2,50 2,50 62,20 70, Aluminium Conductors Size Current Rating Electrical Properties Impedance Volt Drop 1 Sec Short Circuit Rating Physical Properties Nominal Diameters D1 d D2 Mass Ground Ducts Air 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core 3 Core 4 Core (mm²) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) ,4446 2,502 1,80 17,76 20,65 1,60 1,60 24,76 27, ,0465 1,813 2,52 19,33 21,93 1,60 1,60 26,33 29, ,7749 1,342 3,61 21,87 25,05 1,60 1,60 29,07 32, ,5388 0,9333 5,05 24,76 29,27 1,60 1,60 31,96 37, ,3934 0,681 6,86 28,68 33,73 2,00 2,00 37,08 42, ,3148 0,545 8,66 31,09 35,44 2,00 2,00 39,89 44, ,2607 0,452 10,83 33,99 39,39 2,00 2,50 42,79 49, ,2133 0,369 13,35 37,80 44,51 2,00 2,50 47,10 54, ,1708 0,296 17,32 42,60 50,04 2,50 2,50 52,90 61, Under short circuit conditions a maximum conductor temperature of 160ºC is allowed for a maximum of 1 second VOLTEX CATALOGUE
19 BELLS AND MAINS LOW VOLTAGE PVC CABLE Definition of ECC Cable ECC - Earth Continuity Conductor (SANS ) When an improved conductivity in the earth continuity circuit of (SWA) steel wire armoured multicore cable is required, an appropriate number of steel armour wires may be replaced by tinned hard drawn copper wires of the same nominal diameter. The copper wires shall comply with the relevant requirements of Sans D1 D2 d PVC PVC SWA ECC PVC (mm²) 2 Core 3 Core 4 Core 1,5 F43 F45 F47 2,5 F50 F52 F54 4 F57 F59 F61 6 F64 F66 F68 10 F71 F73 F75 16 F77 F79 F81 25 F374 F376 F F381 F383 F F389 F F395 F F401 F F407 F F412 F F F F850 LHFR (Low Halogen) Blue Stripe cables have specially formulated PVC that reduces the emission of hydro-chloric acid during burning of the cables. (LOHAL ) D1 D2 d COPPER PVC PVC SWA PVC (mm²) 2 Core 3 Core 4 Core 7 Core 12 Core 19 Core 27Core 37 Core 1,5 F1793 F1794 F1795 F1814 F1815 F1816 F1818 F1819 2,5 F1797 F1798 F1799 F1801 F1832 F1833 F1835 F F1782 F1783 F1784 F1786 F1844 F1845 F1846 F F1788 F1789 F1790 F F1804 F1805 F F1820 F1821 F F1830 F F1841 F F1850 F F1852 F F F1807 F F1812 F F1823 F F1828 F F1838 F Items above with (-) in the codes column, as well as aluminium are available on special request. VOLTEX CATALOGUE 59 3
20 MULTICORE PVC CABLE Low-Voltage Armoured Cable 600/1000V Electrical and physical properties of Multicore PVC Insulated PVC Bedded SWA PVC sheathed 600/1000V cables with stranded copper conductors manufactured to SANS d D1 = Diameter over bedding sheath d = Diameter of armour wire Technical Data D1 D2 D2 = Diameter over outer sheath 1.5mm 2 Electrical Properties Physical Properties Multicore Cables Current Rating Nominal Diameters Product Impedance Capacitance Mass Ground Ducts Air (mm) Code No. of Cores (A) (Ω/km) (nf/km) D1 d D2 (kg/km) , ,1 1,25 13,8 422 F , ,6 1,25 14, , ,5 1,25 15, , ,3 1,25 15, , ,4 1,25 17, , ,4 1,25 17,0 629 F , ,6 1,25 18, , ,8 1,25 20, , ,3 1,25 21,2 901 F , ,2 1,60 22, , ,2 1,60 25, F , ,4 1,60 29, , ,9 1,60 29, F , ,7 1,60 30, , ,9 1,60 32, mm 2 Multicore Cables Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Mass Ground Ducts Air (mm) No. of Cores (A) (Ω/km) (nf/km) D1 d D2 (kg/km) , ,0 1,25 14,7 475 F , ,6 1,25 15, , ,6 1,25 16, , ,5 1,25 17, , ,7 1,25 18, , ,7 1,25 18,5 756 F , ,0 1,25 18, , ,6 1,60 22, , ,1 1,60 24, F , ,0 1,60 25, , ,4 1,60 28, F , ,1 1,60 32, , ,7 1,60 32, F , ,6 2,00 34, F , ,4 2,00 37, Product Code Items above with (-) in the codes column, as well as aluminium are available on special request VOLTEX CATALOGUE
21 MULTICORE PVC CABLE 4mm 2 Multicore Cables No. of Cores Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Ground Ducts Air (mm) (A) (Ω/km) (nf/km) D1 d D2 (kg/km) , ,2 1,25 16,3 597 F , ,9 1,25 17, , ,3 1,25 18, , ,6 1,25 19, , ,9 1,25 21, , ,9 1,25 21,0 986 F , ,1 1,25 24, , ,2 1,60 27, , ,4 1,60 28, F , ,8 1,60 29, , ,9 2,00 32, F , ,0 2,00 38, , ,2 2,00 39, , ,8 2,00 43, , ,2 2, Mass Product Code 6mm 2 Multicore Cables No. of Cores Electrical Properties Physical Properties Current Rating Nominal Diameters Impedance Capacitance Ground Ducts Air (mm) (A) (Ω/km) (nf/lm) D1 d D2 (kg/km) , ,8 1,25 17,4 684 F , ,6 1,25 18, , ,9 1,25 19, , ,3 1, , ,7 1,60 24, Mass Product Code PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature Ambient Air Temperature (Free Air Shaded) Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 70ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. VOLTEX CATALOGUE 61 3
22 TEXOPLAST FLAT CABLE - TPLF Cable Construction Conductor of copper, finely stranded to class 5/6, cores PVC insulated, laid up in parallel, certain multicores have core groups separated by a web, PVC outer sheath, black. Core Identification: Up to 4 cores : coloured 5 cores and more : black with white numbering, earth core Cable description bearing - O without earth core Cable description bearing - J with green/yellow earth core Application: TPLF cables can be used in dry, damp or wet environments as power, control and instrumentation cables. TPLFC cables qualify as TPLF but offer screened cores, pairs or bundled core assemblies (b) of up to 80% coverage. TPLFT cables qualify as TPLF but offer tension relief steel cores and fire retardant sheath. PVC flat cable is preferably used indoors, in electrification systems where it is subjected to lots of flexing in a single plane i.e. cranes, hoists, conveyor systems, machine tools, lifts etc. Technical Data Maximum operating Voltage AC up to 1,5mm² Maximum operating Voltage AC from 2,5mm² Maximum operating Voltage DC up to 1,5mm² Maximum operating Voltage DC from 2,5mm² Test Voltage AC 450V/750V 600V/1000V 675V/1125V 600V/1500V 3000V Condutor resistance to DIN/VDE 0295 Class 5 Temperature range mobile - 15 C to +70 C fixed - 40 C to + 70 C Current Capacity VDE 0100 Derating VDE 0100 Specification according to VDE 0281 Part Minimum bending radius Tensile stress Marking mobile - 10x cable thickness fixed - 4x cable thickness not to exceed 15N/mm 2 of total core cross section of Type TPLF printed or embossed Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) TPLF-J 4 x 1,5 0,26 5,5 x 15,5 0,15 4 x 2,5 0,26 5,9 x 19,0 0,22 4 x 4 0,31 7,1 x 22,0 0,31 4 x 6 0,31 7,8 x 25,0 0,42 4 x 10 0,41 9,9 x 31,5 0,67 4 x 16 0,41 11,2 x 36,5 0,95 4 x 25 0,41 13,0 x 42,5 1,42 4 x 35 0,41 17,0 x 50,0 2,00 4 x 50 0,41 20,0 x 63,0 2,96 4 x 70 0,509 23,0 x 72,0 3,96 4 x 95 0,509 25,0 x 83,0 5,32 7 x 4 0,31 7,1 x 38,0 0,54 7 x 6 0,31 7,8 x 43,0 0,74 8 x 1,5 0,26 5,2 x 30,0 0,29 8 x 2,5 0,26 5,9 x 38,0 0,42 12 x 1,5 0,26 5,2 x 41,5 0,39 12 x 2,5 0,26 5,9 x 52,0 0, VOLTEX CATALOGUE
23 TEXOPLAST FLAT CABLE - TPLF Flat Cable - TPLF Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) TPLFC - J Screened 4 x 1 0,21 5,0 x 13,9 0,13 6 x 2,5 0,26 9,9 x 36,7 0,58 8 x 1,5 0,26 6,0 x 32,4 0,38 12 x 1,5 0,26 6,0 x 52,0 0,61 TPLFCb - Screened 5 x (4 x 0,5) - O 0,21 9,2 x 35,5 0,52 7 x (4 x 0,5) - O 0,21 10,3 x 50,0 0,75 7 x (3 x 1) - J 0,21 10,3 x 50,0 0,76 14 x (4 x 0,5) - O 0,21 10,3 x 100,0 1,51 TPLFT - J 2 - Tension Relief Cores 4 x 1,5 0,26 5,5 x 20,0 20,0 4 x 16 0,41 11,2 x 51,4 51,4 12 x 1,5 0,26 6,4 x 50,2 50,2 Available on request. Lead times need to be confirmed at the time the order is placed. TEXOPLAST SPECIAL LIFT FLAT CABLES - TPLFY Special Lift Flat Cables - TPLFH (LWL) - O Cable Construction 1. Flexible PVC-insulated stranded cores, alternate left and right stranding lay, laid up in parallel. 2. Optical fibre cable (LWL). 3. Low-elastic supporting elements. 4. PVC outer sheath Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Maximum Weight Maximum Single Suspension Height (mm²) (mm) (mm) (kg/m) (m) TPLFH (LWL) - O 12 x 1 + 2LWL 0,2 + *100/140 µm 51 x 6,4 0,52 80 Special Lift Flat Cables - TPLFT (TELF) - O Cable Construction 1. 6-taped control cable groups comprising of bundled left and right hand laid assemblies of 5 flexible PVC-insulated cores laid around a manila rope centre, cores having an extra short lay, taped and laid up in parallel Telephone cable group which comprises of 4 flexible PVC insulated cores laid up around a central member in quad configuration, collectively screened and polyethylene sheathed. 3. High tensile steel carrier elements. 4. PVC outer sheath, cold resistant Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Maximum Weight Maximum Single Suspension Height (mm²) (mm) (mm) (kg/m) (m) TPLFH (telf) - O 34 x 1 0,15 76 x 11 1, Available on request. Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 63 3
24 PENDANT CABLE - PVC Cable Construction Conductor of copper, finely stranded to class 5/6 - cores PVC insulated - laid up in shorty corelay - taped - Nitrile outer sheath with integrated tension relief stainless steel ropes positioned opposite each other Core Identification: All cores are black and numbered with white print Cable description bearing - J with green/yellow earth core Application Pendant Cable can be used in dry, damp or wet enviroments as power and control cable. The usage extends to hoists, cranes, stacking systems, conveyor systems, elevators etc. Technical Data Max. operating Voltage AC Max. operating Voltage DC Test Voltage AC 600 V 900 V 3000 V Condutor resistance To DIN/VDE 0295 Class 5/6 Temperature range Mobile - 20 C to + 70 C Current Capacity VDE 0100 Derating VDE 0100 Specification According to VDE 0250 Min. bending radius tensile stress Marking Mobile 15x cable thickness Not to exceed 15N/mm 2 to VDE total core cross section Embossed Number of Cores and Rated Cross Section Maximum Diameter of Single Strand Maximum Outer Dimension Weight (mm²) (mm) (mm) (kg/m) PENDANT - J - Yellow - Class 5 27 x 1 32 x 0,20 21,7-34, 0 0,70 8 x 1,5 30 x 0,25 16,0 25,5 0,43 12 x 1,5 30 x 0,25 17,0 28,0 0,51 20 x 1,5 30 x 0,25 21,5 34,0 0,72 PENDANT - J - Black - Class 6 20 x 1,5 84 x 0,15 21,5 34,0 0,73 Available on request. Lead times need to be confirmed at the time the order is placed VOLTEX CATALOGUE
25 SINGLE CORE PVC PVC CABLE Flexible Wiring 300/500V and 600/1000V Cable Description High conductivity annealed stranded copper conductors to SANS 1411 Part 1. Insulated with general purpose grade PVC in plain colours to SANS 1411 Part 2. Installation Information For the wiring of : Industrial Buildings Control Panels Technical Data Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 600/1000V Sheath Identification : Black Packaging : 300/500m Drums D1 = Diameter over conductor D2 = Diameter over PVC sheath D1 D2 Cables A.C. or D.C. Cables in Trefoil Formation Rated Nominal Nominal Impedance Voltage Drop Voltage Drop Area Diameters Mass Product Current Rating per Amp Current Rating per Amp Code per metre per metre (mm 2 ) D1 D2 (kg/km) (Ω/km) Ground Air (mv) Ground Ducts Air (mv) 25 5,95 11, , , , ,00 12, , , , ,15 15, , , , ,79 16, , , , ,54 19, , , , ,96 20, , , , ,39 22, , , ,30 F ,10 24, , , ,20 F ,71 27, , , ,20 F ,45 30, , , ,20 F ,30 34, , , ,20 F ,51 37, , , ,20 F ,15 43, , , ,10 F1972 PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature (ºC) Ambient Air Temperature Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 70ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. Rating based on two touching cables installed in a duct. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 70 C. VOLTEX CATALOGUE 65 3
26 SINGLE CORE XLPE PVC CABLE General Purpose Wire 600/ 1000V Cable Description High conductivity annealed stranded or solid copper conductors to SANS 1411 Part 1. Insulated with XLPE plain colours to SANS 1411 Part 4. Installation Information For the wiring of : Industrial Buildings Control Panels Technical Data Properties Specifications : SANS Temperature Range : -10 C to 90 C Voltage Rating : 600/1000V Sheath Identification : Black Packaging : 300/500m Drums D1 = Diameter over conductor D2 = Diameter over PVC sheath D1 D2 Rated Area Cables A.C. or D.C. Cables in Trefoil Formation Nominal Nominal Diameters Impedance Voltage Drop Voltage Drop Mass Ground Current Rating per Amp Current Rating per Amp per metre per metre (mm 2 ) D1 D2 (kg/km) (Ω/km) Ground Air (mv) Ground Ducts Air (mv) 25 5,95 11, , , ,7-35 7,00 12, , , ,2-50 8,15 14, , , ,9-70 9,79 16, , , , ,54 17, , , , ,96 19, , , ,4 F ,39 21, , , , ,10 23, , , ,3 F ,71 26, , , ,2 F ,45 30, , , ,2 F ,30 33, , , ,2 F ,51 36, , , ,2 F ,15 42, , , ,2 F1974 Product Code PVC Current Ratings are based on the following Environmental Parameters Maximum Sustained Conductor Temperature Ground Temperature (ºC) Ambient Air Temperature Ground Thermal Resistivity Minimum Trench or Duct Depth of Laying 90ºC 25ºC 30ºC 1,2 K.m/W 500mm Items above with (-) in the codes column, as well as aluminium are available on special request. Rating based on two touching cables installed in air. Assumed ambient air temperature is 30 C. Assumed maximum conductor temperature is 90 C VOLTEX CATALOGUE
27 ARMADAC PVC PVC SWA PVC (FR) Black/Red 1.9/3.3kV d Cable Description Electrical and physical properties of 3 core PVC insulated PVC bedded SWA PVC sheathed 1.9/3.3kV cables with copper conductors and manufactured to D1 = Diameter over bedding sheath SANS d = Diameter of armour wire D1 D2 = Diameter over outer sheath D2 Installation Information The cost effectiveness of transferring power over long distances through intermediate step-up and step-down systems is desirable for the electrification of industrial and residential installations, including game lodges and agricultural industry applications. Armadac consists of 3 circular stranded plain soft copper conductors, PVC insulated, PVC bedded, Steel Wire Armoured, PVC sheathed, 1.9/3.3kV manufactured to SANS Ideally utilised for the transfer of electricity over long distances. Advantages of using an intermediate voltage cable over the conventional 400V 3-phase system offered by the increased voltage of 3,3kV include the fact that volt drop will be considerably lower and small conductor sizes (10mm², 16mm² or 25mm²) will suffice for most applications. The Armadac cable is steel wire armoured and provides a robust mechanical protection to the cable, hence it is suitable to be installed underground. Furthermore, Armadac offers additional protection against attack by rodents and other animals as provided by the steel wire armouring. The steel wire armouring can also be utilised as an earth continuity path, therefore eliminating the need for an external earth conductor. Armadac makes use of circular cores which limits electrical stress in the insulation and also incorporates a flame retardant PVC Sheath, which limits the spread of fire. Properties Specifications : SANS Temperature Range : -10 C to 70 C Voltage Rating : 1900/3300V Core Identification : Red, Yellow, Blue Packaging : Available on 500m wooden drums Technical Data Electrical Properties Physical Properties Current Rating 1 Sec Nominal Diameters Impedance Short Volt Drop Ground Ducts Air (Z) Circuit D1 d D2 Rating Approx. Mass Product Code (mm 2 ) (A) (Ω/km) (mv/a/m) (ka) (mm) (kg/km) ,19 3,793 1,4 20,7 1,6 27, F ,38 2,390 2,2 22,8 1,6 29, F ,8749 1,515 3,4 24,9 1,6 31, F2811 Recommended depth of lay 500mm. Soil thermal resistivity 1.2 km/w. Soil temperature at 25 C. In ground at 500mm depth. Armadac is a registered trademark of Aberdare Cables, a member of the Powertech Group. VOLTEX CATALOGUE 67 3
28 AIRDAC SNE CABLE House Service Connecting Cable with or without Pilot Cores Cable Description Circular stranded hard drawn copper phase conductor, XLPE insulated with concentrically arranged identified neutral and bare earth conductors. Polyethylene sheathed 600/1000V service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS Technical Data Small overall diameter - concentric construction (SNE - Seperate Neutral Earth). Lower mass - due to smaller diameter - no steel wire armour. Increased safety - reliable earthing. Improved reliability - UV stable sheath and core insulation and water blocked. Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer. Easy strip with nylon ripcord. Size Phase Conductor Resistance (Ohm/km) DC Earth Size Electrical Properties Neutral Size Phase Core Impedance Current Rating Pilot Cores (No. x OD) Solid at 20 C (mm²) (mm²) (Z) (Ohm/km) (A) (mm) 10 1,90 7,5 10 2, x 1,13 F , , x 1,13 F215 Mechanical Properties Size Phase Conductor }No. x OD{ Nominal Insulation Thickness Neutral Conductor }No. x OD{ Earth Conductor {No. x OD} Nominal Sheath Thickness Cable OD Cable Mass )mm( )mm( )mm( )mm( )mm( )mm( (kg/km) 10 7 x 1,35 1,0 7 x 1,33 3 x 1,78 1,6 12, x 1,67 1,0 7 x 1,76 3 x 2,20 1,6 14,5 485 AIRDAC II CNE CABLE House Service Connect Cable Description Circular stranded hard-drawn copper phase conductor, XLPE insulated with concentrically arranged bare earth conductors. Polyethylene sheathed 600/1000 V house service connection cable. Nylon ripcord laid under sheath. Manufactured to SANS Technical Data Small overall diameter - concentric construction. Lower mass - due to smaller diameter - no steel wire armour. Increased safety - reliable earthing. Improved reliability - UV stable sheath and core insulation. Tamper and vandal proof - unauthorised access to phase conductor inhibited by concentric layer. Easy strip with nylon ripcord. Electrical Properties Size Phase Conductor Resistance Phase Core Impedance Current Rating Symmetrical Short Circuit Rating for 1s (Ohm/km) DC at 20 C (Z) (Ohm/km) (A) ka 4 4,80 5, ,572 F ,90 2, ,431 F210 Mechanical Properties Size Phase Conductor {No. x OD} Nominal Insulation Thickness Earth Size Earth Conductor {No. x OD} Nominal Sheath Thickness Cable OD Cable Mass )mm( )mm( (mm²) )mm( )mm( )mm( )kg/km( 4 7 x 0,92 1,0 4 8 x 0,85 1,4 9, x 1,45 1, x 0,85 1,4 11,0 249 In air, with 30 C ambient with maximum conductor temperature 90 C. Airdac is a registered trademark of Aberdare Cables, a member of the Powertech Group VOLTEX CATALOGUE
29 AERIAL BUNDLE CONDUCTOR (ABC) CABLE Cable Description Supporting-core system consists of three phase cores of hard-drawn stranded compacted aluminium conductors insulated with carbon-loaded XLPE laid up around an aluminium-alloy supporting core insulated with carbon loaded XLPE to ensure UV protection. Additional sub-conductors optional in both self-supporting and supporting-core systems. Installation Information Economical Flexible Safe Vandal proof Durable Aesthetically pleasing Adaptable Supporting Core Properties Specification : SANS 1418 Part 1 and 2 Temperature Range : -10 C to 80 C Voltage Rating : 600/1000V Core Identification : Phase 1, 2 and 3 indented Non strain-bearing neutral, 2 longitudinal ribs on opposite surfaces 0,5mm x 1,00mm Strain-bearing (supporting) neutral. 1 longitudinal rib on one surface 0,5mm x 1,00mm Packaging : Available on 500m wooden drums. Technical Data Based on 3 Core Plus Insulated Neutral Current Rating Short Circuit Rating Electrical Properties Conductor Resistance at 20 C Conductor Resistance (AC) at 80 C Supporting Core Size Supporting Core System Induction Reactance at 50Hz Impendance (z) at 50Hz at 80 C (mm 2 ) (A) (ka) (Ω/km) (Ω/km) (mm 2 ) (Ω/km) (Ω/km) ,3 1,200 1,490 54,6 0,101 1, ,2 0,868 1,078 54,6 0,097 1, ,6 0,641 0,796 54,6 0,089 0, ,4 0,443 0,550 54,6 0,086 0, ,5 0,320 0,397 54,6 0,081 0, ,0 0,253 0, ,079 0, ,8 0,206 0, ,079 0,268 Mechanical Properties Conductor Core Supporting Core System Diameter Diameter Supporting Maximum Phase Cores Min Max Min Max Core Size Assembly Diameter Assembly Mass Design Load (mm 2 ) (mm) (mm 2 ) (mm) (kg/km) (kn) 25 5,6 6,5 8,4 9,6 54, ,6 7,5 9,8 11,1 54, ,7 8,6 10,9 12,3 54, ,3 10,2 12,9 14,3 54, ,0 12,0 14,6 16,2 54, ,5 13,5 16,1 17,5 70, ,9 15,0 17,5 19,2 95, Above Plus 25mm² Auxiliary Core N/A N/A N/A N/A N/A N/A Temperature C Factor 1,11 1,05 1,00 0,94 0,88 Items above with (-) in the codes column are available on special request. Also available in bare neutral, 1 core and insulated neutral, 2 core and insulated neutral and 3 core and insulated neutral configurations. For further details on our Aerial Bundle Conductor Range please see our website or your nearest branch. Continuous current ratings are given for ambient temperature of 35 C, and maximum conductor temperature of 80 C. For other ambient temperatures use adjoining rating factors. Short circuit ratings of 1 second duration, for a final conductor temperature of 130 C. Available in bare neutral configuration. VOLTEX CATALOGUE 69 3
30 OVERHEAD ALUMINIUM CONDUCTORS ACSR Aluminium Conductor Steel Reinforced Overview Aluminium conductors have achieved wide acceptance all over the world for use in overhead transmission and distribution lines. Generally a steel core is used with the aluminium to give the conductor mechanical strength. This arrangement is termed Aluminium Conductor Steel Reinforced or ACSR. Conductors comprised entirely of aluminium are known as All Aluminium Conductors or AAC. These conductors are extensively used for busbars in outdoor substations where spans are short. All Aluminium Alloy Conductors or AAAC consist of an alloying of aluminium to give a tensile strength in excess of that of AAC, allowing longer spans. These conductors are recommended for coastal areas where severe corrosion is a problem. Hard drawn aluminium in H9 temper is used in both ACSR and AAC. High strain steel wire is used in ACSR and this is sometimes protected from corrosion by an application of grease. Such measures are particularly adopted when the conductor is intended for use in aggressive environments as encountered in coastal regions. Physical and Electrical Properties for Popular ACSR Sizes Standing/ Equival. Overall Aluminium Mass Ultimate DC Current Wire Tensile Resistance Type Copper Area Diameter Area Rating Product Diameter (kg/km) Strength at 20 C Code (mm 2 ) (mm) (mm) (mm 2 ) Aluminium Steel Total (N) Ohms/km (A) Squirrel 12,90 6/1/2,11 6,33 20,98 57,70 27,50 85, , F2042 Gopher 16,30 6/1/2,36 7,08 26,25 72,20 34, , F2043 Fox 22,58 6/1/2,79 8,37 36, , , F2045 Ferret 25,81 6/1/3,00 9,00 42, , , F2046 Rabbit 32,26 6/1/3,35 10,05 52, , , F2047 Mink 38,71 6/1/3,66 10,98 63, , , F2048 Hare 64,52 6/1/4,72 14,16 104, , F3362 6/4,72 - Dog 64,52 14,15 104, , /1,57 F2052 Wolf 96,77 30/7/2,59 18,13 158, , F2057 Panther 129,00 30/7/3,00 21,00 212, , F2995 Bear 161,30 30/7/3,35 23,45 264, , F2972 Goat 193,50 30/7/3,71 25,97 324, , F2059 Items above with (-) in the codes column are available on special request. For further details on our Overhead Aluminium Conductor Range please see our website or your nearest branch. Eskom marked product available on request. Lead times need to be confirmed at the time the order is placed VOLTEX CATALOGUE
31 CABLE GLAND INDICATOR The CONTRACTING TOOL which fits in your pocket. Voltex introduces, the essential new mobile app for electrical contractors. Now there s an app that will make your life easier, no matter where you are. Our mobile app gives electrical contractors a wealth of features*: Energy Efficiency Comparison Calculator Cable Gland Indicator Motor Control Chart Voltex Branch Locator with map *Indications are for guideline purposes only and may vary for individual results. Search for Voltex on Apple istore or Google Play and download now. Any queries please info@voltex.co.za. iphone is a trademark of Apple Inc. registered in the U.S. and other countries. Google play is a trademark of Google Inc. your electrical connection For extended & complete range visit Minimum quantity orders may apply. Dimensions generally shown in mm and subject to technical change. Voltex codes and descriptions have been used above. Use Voltex K8 codes facebook.com/voltexsa andtwitter.com/voltexsa VOLTEX CATALOGUE 71 3
32 MV XLPE CABLE Medium Voltage Electric Cable 6.6kV to 33kV Properties and applications Due to the fact that Vultex XLPE insulation is resistant to high temperatures, it is obvious that higher temperatures are permissible in the cable. For XLPE, continuous conductor temperature up to 90 C are permissible, whilst for some hours a temperature of 130 C is permissible. In case of short-circuit the conductor can withstand considerably higher temperature (up to 250 C). This important specific characteristic, in contrast with those generally applicable to plastics, give XLPE insulated cables the following advantages: Suitable for a sustained conductor temperature of 90 C as a result of which a high current carrying capacity is obtained. Suitable up to 125 hours/annum, (no event being longer than 8 hours continuously) at a conductor temperature of 130 C so that emergency loads can be tolerated. No drainage problems. Clean handling. Relatively low cost per installed kva. Technical Data Electrical and Physical Properties of 3 core XLPE insulated PVC bedded, steel wire armoured, PVC sheathed 6.35/11kV cables to SANS 1339 Type A (Individually screened). Copper Conductors Standard Aluminium Conductors Current Rating (Ground) Electrical Properties Physical Properties Electrical Properties Physical Properties Impedance 1 Second Short Circuit Rating Diameter Overall Cable Mass Current Rating (Ground) Impedance 1 Second Short Circuit Rating Diameter Overall Cable Mass (mm 2 ) (A) (Ω/km) (ka) (mm) (kg/km) (A) (Ω/km) (ka) (mm) (kg/km) ,9353 3,575 47, ,6783 5,005 49, ,5067 7,150 52, ,600 52, , ,010 56, ,440 56, , ,585 60, ,740 60, , ,160 64, ,040 64, , ,450 68, ,800 68, , ,455 72, ,020 72, , ,320 79, ,080 79, , ,900 85, ,600 85, VOLTEX CATALOGUE
33 PAPER INSULATED CABLES Paper Armoured (SWA or DSTA) Cable Paper Belted (up to 11kV) Cable Paper Screened (11kV and above) Cable Paper Unarmoured Cable Overview Paper insulated cables have been in use longer than any other type of cable insulation and, due to the reputation built up over the years, are still today a great favourite with engineers. When properly selected and correctly installed this product can be relied upon to provide a satisfactory and trouble-free performance for many years. Application Paper insulated lead covered cables can be used in many electrical distribution and reticulation applications. Special constructions are also available for use in specialised applications including: Electrical distribution in the petrochemical industry. Mining - a special construction for shaft installation is available with water blocking as well as flame retardancy. Fire and explosion hazardous areas. Submarine cables. Made to SANS 97. Technical Services Quality Assurance, Quality Control and Testing As electric power cables are manufactured to provide many years of service, it is necessary that the raw materials used are of the highest quality and conform to the rigid specifications laid down by South African Bureau of Standards. This also means that the production process has to be carefully controlled, particularly in areas where heating, drying or cooling cycles can be critical to the overall characteristics and electrical properties of the cable. Chemical, physical and electrical tests are carried out at various stages of manufacture. Final tests are all in accordance with SANS 97. Quality assurance systems are in compliance with SABS ISO 9000 series. Manufacturing Range Conductor Size 16mm 2 to 1000mm 2 Conductor Material Standard Copper Standard Aluminium No. Of Cores 1 3 Voltage 3.3kV 6.6kV 11kV 22kV 33kV Belted Electric Field Control Belted Screened Bedding Jute Hessian PVC EVA MDPE HDPE Armouring Aluminium Wire Steel Tape Steel Wire Steel Wired Serving Jute Hessian PVC EVA MDPE HDPE VOLTEX CATALOGUE 73 3
34 TABLE 17: 6.35/11KV 3 CORE GENERAL PURPOSE BELTED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) A.C Resistance Impedance Copper Conductors ohms/km 0,8700 0,6272 0,4633 0,3211 0,2316 0,1839 0,1494 0,1200 0,0921 0, Aluminium Conductors ohms/km 1,4419 1,0430 0,7703 0,5325 0,3849 0,3045 0,2481 0,1979 0,1513 0, Copper Conductors ohms/km 0,8779 0,6371 0,4751 0,3365 0,2499 0,2053 0,1739 0,1481 0,1245 0, Aluminium Conductors ohms/km 1,4421 1,0492 0,7777 0,5423 0,3972 0,3183 0,2640 0,2166 0,1734 0, Maximum Sustained Current Rating Ground Copper Conductors A Aluminium Conductors A Dimensional Data Conductor Size (mm 2 ) Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 31,38 33,64 33,49 36,50 39,33 41,73 44,36 47,42 52,14 56,15 - Steel Tape Armoured Served mm 44,09 47,15 47,00 50,01 52,84 55,24 57,87 60,93 65,65 69,66 - Single Wire Armoured Served mm 44,89 48,15 48,00 51,01 53,84 56,24 60,17 63,23 67,95 74,52 - Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km TABLE 18: 11/11KV 3 CORE GENERAL PURPOSE BELTED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) A.C Resistance Impedance Maximum Sustained Current Rating Ground Copper Conductors ohms/km 0,8700 0,6272 0,4633 0,3211 0,2316 0,1839 0,1494 0,1200 0,0921 0, Aluminium Conductors ohms/km 1,4419 1,0430 0,7703 0,5325 0,3849 0,3045 0,2481 0,1979 0,1513 0, Copper Conductors ohms/km 0,8779 0,6371 0,4751 0,3365 0,2499 0,2053 0,1739 0,1481 0,1245 0, Aluminium Conductors ohms/km 1,4468 1,0492 0,7777 0,5423 0,3965 0,3183 0,2640 0,2166 0,1734 0, Copper Conductors A Aluminium Conductors A Dimensional Data Conductor Size (mm 2 ) Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 35,14 37,60 37,67 40,68 43,51 45,71 48,32 51,40 56,54 60,53 - Steel Tape Armoured Served mm 48,65 51,11 51,18 54,19 57,02 59,22 61,83 64,91 70,05 74,04 - Single Wire Armoured Served mm 49,65 52,11 52,18 55,19 59,32 61,52 64,13 67,21 74,91 78,90 - Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km Lead times need to be confirmed at the time the order is placed VOLTEX CATALOGUE
35 TABLE 19: 6.35/11KV 3 CORE GENERAL PURPOSE SCREENED CABLES Fully impregnated armoured and served to SANS 97 Electrical Data Conductor Size (mm 2 ) Product Code A.C Resistance Impedance Maximum Sustained Current Rating Ground Copper Conductors ohms/km 0,8700 0,6272 0,4634 0,3211 0,2315 0,1839 0,1494 0,1199 0,092 0, Aluminium Conductors ohms/km 1,4419 1,0430 0,7704 0,5325 0,3848 0,3045 0,2481 0,1978 0,1513 0, Copper Conductors ohms/km 0,8788 0,6382 0,4769 0,3381 0,2517 0,2073 0,1760 0,1503 0,1267 0, Aluminium Conductors ohms/km 1,4472 1,0497 0,7786 0,5429 0,3973 0,3191 0,2650 0,2176 0,1746 0, Copper Conductors A Aluminium Conductors A Dimensional Data Conductor Size (mm 2 ) Product Code Diameter Cable Mass Over Serving Copper Conductors Aluminium Conductors Over Lead Sheath mm 32,79 35,05 37,73 38,20 41,02 43,21 45,84 48,90 53,35 58,06 - Steel Tape Armoured Served mm 45,50 48,56 51,24 51,71 54,53 56,72 59,35 62,41 66,86 71,57 - Single Wire Armoured Served mm 46,30 49,56 52,24 52,71 55,53 57,72 61,65 64,71 69,16 76,43 - Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km Steel Tape Armoured Served kg/km Single Wire Armoured Served kg/km Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 75 3
36 CONTROL AND INSTRUMENTATION CABLES We supply an extensive range of instrumentation, control and telecommunication cables for the industrial market. These cables are used to provide voice and data services including measurement, sensing and control systems through the interconnection of equipment and instrumentation. Control cables are used in industrial power or control circuits for conveying electrical signals to associated equipment and instruments. These cables are suitable for installation in cable trays, conduit or trenches as well as other outdoor locations. A wide range of solid or stranded copper conductor, insulated with Polyethylene, Cross Linked Polyethylene (XLPE) or PVC in single or multi pair/multi triad and multicore industrial cables are available. These products are designed and manufactured according to specific or international standards. Cores are overall screened, whereas pairs can have screened over the laid-up pairs/triads (overall screened), or have screens around each individual pair or triad in combination with an overall screen (individually+overall screened) in order to minimise cross talk and ground loop interference. Aluminium/Polyester foil is used for screening, and Tinned Copper Braid is also available in certain constructions. Various sheathing and armouring designs are available, and include overall screening and armouring with Aluminium-Polyethylene-Laminate (APL) tape with Polyethylene as an outer sheath, or Steel Wire Armouring with PVC or Polyethylene as an outer sheath. A comprehensive range of sheathing material is available ranging from Polyethylene and PVC to Limiting Oxygen Index (LOI) materials and Low Smoke Zero Halogen (LSZH) options. For critical systems and applications a wide range of intrinsically safe industrial cable is available VOLTEX CATALOGUE
37 DEKARON (UNARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Unarmoured Cable Construction Stranded annealed copper conductor, cross-linked Polyethylene (XLPE) insulated, the laid-up cores aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black, white red and blue up to four core, thereafter white cores identified by black alphanumerical marking. Size Cores Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm²) (mm) (mm) (m) (kg) 300/500V 0,5 3 7, ss ,5 4 7, ss F1239 0,5 7 8, s , , s F3180 0, , , , , , /1000V 1,0 3 7, ss F1174 1,0 4 8, s F1175 1,0 7 10, s F1176 1, , F1177 1, , F1178 1, , , , F /1000V 1,5 3 8, s F1180 1,5 4 10, s F1181 1,5 7 11, F1182 1, , F3127 1, , F3128 1, , F3129 1, , F3130 Items above with (-) in the codes column are available on special request. The above cable is also available in alternative constructions such as low - halogenated (black outer sheath with blue stripe) and zero - halogenated (black outer sheath with white stripe) flame retardant cable. This type of cable is generally referred to as "Dekaron" unarmoured cable. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 77 3
38 DEKARON (ARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Steel Wire Armoured Cable construction Stranded annealed copper conductor, XLPE insulated, the laid-up cores aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, galvanised single wire armoured, flame retardant PVC sheathed. Core Identification: Black, white red and blue up to four core, thereafter white cores identified by black alphanumerical numbering. Voltage Rating : - 0.5mm² = 300/500V, 1.0 And 1.5mm² = 600/1000 Size Cores Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) 300/500V 0,5 3 11, s ,5 4 12, s ,5 7 14, , , , , , , , , /1000V 1,0 3 12, s ,0 4 13, s ,0 7 15, s , , F3174 1, , , , , , /1000V 1,5 3 13, s ,5 4 15, s ,5 7 16, , , , , , , , , Items above with (-) in the codes column are available on special request. The above cable is also available in alternative constructions such as low - halogenated (black outer sheath with blue stripe) and zero - halogenated (black outer sheath with white stripe) flame retardant cable. This type of cable is generally referred to as "Dekaron" unarmoured cable. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Screens can be either overall aluminium/mylar foil or individual and overall aluminium/mylar foil, and a tinned stranded copper drain wire is always included for each foil screen. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark VOLTEX CATALOGUE
39 DEKARON (APL ARMOURED) CABLE Control Cable - Overall Aluminium/Mylar Foil Screened - Cores Aluminium - Polyethylene - Laminate (APL) Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC sheathed, Aluminium-Polyethylene-Laminate (APL) armoured. Core Identification: White Cores, alphanumerically numbered. Voltage Rating : - 0.5mm² = 300/500V, 1.0 and 1.5mm² = 600/1000V Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) 300/500V 0,5 3 10, s ,5 4 11, F1222 0,5 7 13, , , , , , , or , , /1000V 1,0 3 11, F1170 1,0 4 12, F1225 1,0 7 14, F1172 1, , F1173 1, , or F2896 1, , F3082 1, , F /1000V 1,5 3 12, F3119 1,5 4 13, F3120 1,5 7 15, F3121 1, , F3122 1, , F3123 1, , F3124 1, , F3125 Items above with (-) in the codes column are available on special request. The "Dekaron" range of cable does however also include galvanised single wire armoured (SWA) and Aluminium-Polyethylene-Laminate (APL) armoured cables, which are also available in pairs and triad (trip) constructions. Screens can be either overall aluminium/mylar foil or individual and overall aluminium/mylar foil, and a tinned stranded copper drain wire is always included for each foil screen. Lead times need to be confirmed at the time the order is placed. Dekaron is a Furon trademark. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 79 3
40 PAIRS AND TRIADS OAM UNARMOURED Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs And Triads Unarmoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating : 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG A2 Gland Size Standard Drum Length Gross Drum Weight (mm²) (mm) (mm) (m) (kg) Pairs 0,5 1 5, ss F1237 0,5 2 8, s F1238 0,5 4 10, s F1239 0,5 8 13, F1240 0, , , , , , , , , , ,0 1 6, ss F1241 1,0 2 10, s F1242 1,0 4 12, F1243 1,0 8 16, F1244 1, , F1245 1, , , , ,5 1 7, ss F1246 1,5 2 12, ss F1247 1,5 4 14, or F1248 1,5 8 18, F1249 1, , , , F2812 1, , Triads 0,5 1 5, ss F1252 0,5 4 11, ,5 8 15, , , , , , , , , ,0 1 6, ss F1253 1,0 4 14, ,0 8 18, , , , , ,5 1 7, ss F1254 1,5 4 16, ,5 8 21, , , or Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark VOLTEX CATALOGUE
41 PAIRS AND TRIADS IOAM UNARMOURED Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened- Pairs And Triads - Unarmoured Cable Construction Stranded annealed copper conductor, XLPE Insulated, the laid-up pairs/triads individually and overall aluminium/ Mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 9, s F1211 0,5 4 11, s ,5 8 14, , , , , F3318 0, , , , , , ,0 2 11, F1212 1,0 4 12, F1214 1,0 8 16, F1215 1, , F1216 1, , F1217 1, , ,5 2 12, F1218 1,5 4 15, F1219 1,5 8 19, F2893 1, , , , , , Triads 0,5 4 12, ,5 8 16, , , , , F3320 0, , , , ,0 4 14, ,0 8 19, F2813 1, , , , ,5 4 16, ,5 8 22, , , Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 81 3
42 PAIRS AND TRIADS OAM SWA Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs/Triads Steel Wire Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, flame retardant PVC bedding sheathed, single wire armoured (SWA), flame retardant PVC outer sheathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 1 10, s ,5 2 13, s ,5 4 15, s ,5 8 18, , , , , , , , , , , ,0 1 11, s F1233 1,0 2 15, s F1234 1,0 4 17, ,0 8 21, , , , , , , ,5 1 12, s F1235 1,5 2 17, F1236 1,5 4 20, ,5 8 24, , , , , , , Triads 0,5 1 10, s ,5 4 16, ,5 8 21, , , , , , , , , ,0 1 11, s ,0 4 19, ,0 8 24, , , , , ,5 1 12, s ,5 4 21, ,5 8 28, , , Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark VOLTEX CATALOGUE
43 PAIRS AND TRIADS IOAM SWA Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened Pairs And Triads - Steel Wire Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/ Mylar foil screened, each foil screen with tinned stranded copper drain wire, flame retardant PVC s heathed. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 14,6 146, s F3146 0,5 4 15,9 159, s F3147 0,5 8 19,6 197, F3148 0, ,2 222, F3149 0, ,4 255, F3150 0, ,3 293, F3152 0, ,3 334, or , ,8 349, ,0 2 16,0 161, s or F1206 1,0 4 18,1 181, F1207 1,0 8 21,4 215, F1208 1, ,2 262, F1209 1, ,3 293, F3153 1, ,6 347, F3155 1,5 2 18,0 180, F1210 1,5 4 20,3 204, F3156 1,5 8 25,7 257, F2892 1, ,5 305, F2891 1, ,3 334, F3157 1, ,8 339, F3159 Triads 0,5 4 17,1 172, ,5 8 21,5 215, , ,8 259, , ,4 284, , ,7 347, , ,7 394, ,0 4 20,0 200, ,0 8 25,2 254, , ,5 306, , ,5 336, ,5 4 22,1 221, ,5 8 28,7 288, , ,6 347, Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 83 3
44 PAIRS AND TRIADS OAM APL POLY Instrument Cable - Overall Aluminium/Mylar Foil Screened - Pairs/Triads Aluminium - Polyethylene - Laminate (Apl) Armoured Cable Construction Stranded annealed copper conductor, XLPE Insulated, the laid-up pairs/triads aluminium/mylar Foil screened, tinned stranded copper drain wire, flame retardpant PVC bedding sheathed, Aluminium- Polyethylene-Laminate (APL) armoured. Core Identification: Black and white alpha numerically numbered pairs, black, white and red, alphanumerically numbered triads. Voltage Rating: 250V (Core to Core) Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 1 9,4 85,0 90,0 0-20s F1220 0,5 2 12,7 115,0 153, F1221 0,5 4 14,4 130,0 203, F1222 0,5 8 17,1 155,0 287, F3189 0, ,0 181,0 394, F3190 0, ,7 195,0 471, F3191 0, ,5 221,0 629, , ,4 265,0 772, ,0 1 10,2 92,0 111,0 0-20s 100i 186 F1223 1,0 2 14,6 132,0 205, F1224 1,0 4 16,2 146,0 265, F1225 1,0 8 20,3 183,0 428, F1226 1, ,9 206,0 557, F1227 1, ,3 228,0 706, F1228 1, ,5 258,0 949, ,5 1 11,0 100,0 128,0 0-20s F1229 1,5 2 16,2 146,0 248, F1230 1,5 4 18,4 166,0 354, F1231 1,5 8 22,8 206,0 535, F1232 1, ,3 237,0 730, , ,4 265,0 943, , ,0 297,0 1256, Triads 0,5 1 9,7 88,0 100,0 0-20s ,5 4 15,6 141,0 244, ,5 8 19,8 179,0 392, , ,0 207,0 512, , ,4 229,0 646, , ,1 280,0 919, , ,2 314,0 1217, ,0 1 10,5 95,0 126,0 0-20s F1250 1,0 4 18,4 166,0 357, ,0 8 22,5 204,0 554, , ,7 242,0 773, , ,0 270,0 990, ,5 1 11,4 103,0 148, F1251 1,5 4 20,6 186,0 442, or ,5 8 26,0 234,0 726, , ,4 283,0 1036, Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark VOLTEX CATALOGUE
45 PAIRS AND TRIADS IOAM APL POLY Instrument Cable - Individually And Overall Aluminium/Mylar Foil Screened - Pairs/Triads Aluminium - Polyethylene - Laminate (Apl) Armoured Cable Construction Stranded annealed copper conductor, XLPE insulated, the laid-up pairs/triads individually and overall aluminium/mylar foil screened, tinned stranded copper drain wire, flame retardant PVC sheathed, Aluminium-Polyethylene-Laminate (APL) armoured. Core Identification: Black and white alphanumerically numbered pairs, black, white and red, alphanumerically numbered triads. Size Pairs Nominal OD Minimum Bending Radius ± kg/km CCG BW Gland Size Standard Drum Length Gross Drum Weight (mm 2 ) (mm) (mm) (m) (kg) Pairs 0,5 2 13, F1197 0,5 4 14, F1198 0,5 8 18, F3132 0, , or F3133 0, , F3134 0, , F3136 0, , , , F3137 1,0 2 14, F1199 1,0 4 16, F1200 1,0 8 20, F1201 1, , F1202 1, , F1203 1, , F1204 1,5 2 16, F1205 1,5 4 19, F3140 1,5 8 23, F3141 1, , F3142 1, , F3143 1, , F3145 Triads 0,5 4 16, ,5 8 20, , , , , , , , , ,0 4 18, ,0 8 23, , , , , ,5 4 21, ,5 8 26, , , Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Mylar (clear polyester) is a Du Pont trademark. VOLTEX CATALOGUE 85 3
46 PAIRS OAM DEF SPEC Pvc Insulated Overall Aluminium/Mylar Foil Screened Pairs, Colour Coded To Def. Stan Cable Construction Tinned stranded annealed copper conductor, PVC insulated (150/250V), aluminium/mylar foil screened, tinned stranded copper drain wire, PVC sheathed (Grey). Size Pairs Nominal OD ± kg/km Packing Core Identification CCG A2 Gland Size Product Code (mm 2 ) (mm) (m) 0,22 2 6, DEF STAN ss F1184 0,22 3 6, DEF STAN ss F2653 0,22 4 7, DEF STAN ss F1185 0,22 6 8, DEF STAN ss or 1-20 F2654 0,22 8 9, DEF STAN s F2655 0, , DEF STAN F2656 0, , DEF STAN , , DEF STAN , , DEF STAN , , DEF STAN , , DEF STAN ,50 1 5, DEF STAN ss F1186 0,50 2 7, DEF STAN ss F1187 0,50 3 8, DEF STAN ss - 0,50 4 8, DEF STAN s F1188 0, , DEF STAN s or 1-20 F1189 0, , DEF STAN F1190 0, , DEF STAN F1191 0, , DEF STAN , , DEF STAN , , DEF STAN Pair DEF STAN COLOUR CODING 1 (Red, blue) 2 (Red, blue), (green, yellow) 4 (Red, blue), (green, yellow), (white, black), (brown, violet) 6 (Red, blue), (green, yellow), (white, black), (brown, violet), (orange, pink), (turquoise, grey), (red/blue - green/red) (Red, blue), (green, yellow), (white, black), (brown, violet), (orange, pink), (turquoise, grey), (Red/blue - green/red), (yellow/red - white/red) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue -- green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red/black - brown/black), (yellow/violet - white/violet), (red, yellow), (green, black) (Red, blue), (green, yellow), (white, black) (brown, violet), (orange, pink), (turquoise, grey), (Red/blue - green/red), (yellow/red - white/red), (yellow/blue - white/blue), (orange/blue - green/blue), (Black/blue - grey/blue), (yellow/green - white/green), (orange/green - grey/green), (Red/brown - yellow/brown), (white/brown - grey/brown), (green/black - violet/black), (Red/black - brown/black), (yellow/violet - white/violet), (red, yellow), (green, black), (White, violet), (brown, pink), (orange, grey), (turquoise, blue), (red, black) Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. Also available in individual and overall aluminium/polyester foil screened construction. Mylar (clear polyester) is a Du Pont trademark VOLTEX CATALOGUE
47 CAT 5E SOLID UNSHIELDED TWISTED PAIR (UTP) CABLE Cable Construction 24 American wire guage (AWG) (1/0.51mm) solid plain annealed copper conductor polyolefin insulated, 4 colour coded twisted pairs laid - up and PVC sheathed. Temperature Range 0 C to +50 C (installation) and -20 C to +70 C (installed). Compliance This cable is EC verified and complies with: ISO 11801, TIA/EIA 568a and EN DC Resistance Resistance Electrical Characteristics (Standards) at 20 C Mutual Capacitance Capacitance Skew Velocity of Propagation Ω/km Maximum % nf/km Maximum pf/km Maximum nsec/km Maximum (VOP) Characteristic Impedance Ω (±15%) at 1.0 to 100 Mhz 93, c 100 Electrical Characteristics (Standards) for CAT 5E Frequency Attenuation Near End Cross Talk (NEXT) Power Sum Near End Cross Talk (PSNEXT) Power Sum Equal Level Far End Cross Talk (PSELFEXT) MHz db/100m db db db 1 2,1 65,3 62,3 60,8 4 4,3 56,3 53,3 48,7 10 6,6 50,3 47,3 40,8 16 8,2 47,3 44,3 36,7 20 9,2 45,8 42,8 34, ,8 42,9 39,9 30, ,1 38,4 35,4 24, ,0 35,3 32,3 20,8 Size Pairs Nominal OD Cable Weight (mm 2 ) (mm) (kg/km) Total Weight/ 500m Drum Per 305m Box Fire Safety Compliance 0, , /10.3 IEC Standard Packing 305m easy-pull box or 500m plastic reel F1166 Available in the following coding colours: Pair 1 Pair 2 Pair 3 Pair 4 : Blue/white with blue stripe. : Orange/white with orange stripe. : Green/white with green stripe. : Please see image above. Kindly enquire about our other communication cables such as CAT 6. Lead times need to be confirmed at the time the order is placed. VOLTEX CATALOGUE 87 3
48 OUTDOOR TELEPHONE CABLE Galvanised Wire Armoured Cable Construction Solid annealed copper conductor, PVC insulated, PVC bedding sheathed, galvanised wire armoured, PVC sheathed outdoor telephone cable to Telkom specification 268/271 W/A. Size Pairs Nominal OD Cable Weight Total Weight/ 1000m Drum Maximum Conductor Loop Resistance Minimum Insulation Resistance (mm 2 ) (mm) (kg/100 m) (Ω/km) (MΩ-km) 0,6 2 9,5 21, ,4 37,5 F2670 0,6 4 11,5 28, ,4 37,5 F2671 0,6 5 12,0 31, ,4 37,5 F2672 0,6 6 12,5 34, ,4 37,5 F2673 0, ,0 41, ,4 37,5 F1596 0, ,5 51, ,4 37,5 F2674 0, ,5 58, ,4 37,5 F2675 0, ,0 67, ,4 37,5 F2677 0, ,0 85, ,4 37,5 F2678 0, ,0 124, ,4 37,5-0, ,5 160, ,4 37,5-0, ,0 206, ,4 37,5 F2681 0,9 4 13,0 36,9 450,0 55,8 37,5 F2683 0,9 5 14,0 42,0 485,0 55,8 37,5 F2684 0,9 6 14,5 46,1 543,0 55,8 37,5 F2685 0, ,0 57,9 661,0 55,8 37,5 F2686 0, ,5 74,2 453,0 55,8 37,5 F2687 0, ,5 86,4 514,0 55,8 37,5 F2688 0, ,5 136,3 805,0 55,8 37,5 F2690 0, ,5 160,2 970,0 55,8 37,5 F2691 0, ,5 192,3 1194,0 55,8 37,5-0, ,0 273,5 1597,0 55,8 37,5 - Items above with (-) in the codes column are available on special request. Lead times need to be confirmed at the time the order is placed. INDOOR TELEPHONE CABLE Cable Construction Solid Annealed Copper Conductor (plain or tinned), PVC insulated, white PVC Sheathed indoor telephone cable to Telkom spec 268/271. Size Pairs Nominal OD Cable weight Total Weight/ 1000m Drum Maximum Conductor Loop Resistance Minimum Insulation Resistance (mm) (mm) (kg/m) (Ω/km) (MΩ-km) 0,5 2 3, ,4 37,5 F1597 0,5 3 5, ,4 37,5 F2658 0,5 4 5, ,4 37,5 F2659 0,5 5 5, ,4 37,5 F2660 0,5 6 6, ,4 37,5 F2661 0,5 10 8, ,4 37,5 F1598 0,5 15 9, ,4 37,5 F2662 0, , ,4 37,5 F2663 0, , ,4 37,5 F2664 0, , ,4 37,5 F2665 0, , ,4 37,5 F2666 0, , ,4 37,5 F2667 0, , ,4 37,5 F2668 0, , ,4 37,5 F2669 Lead times need to be confirmed at the time the order is placed. Above codes refer to plain configuraiton VOLTEX CATALOGUE
Low Voltage Cable Range. Edition 4 Brochure
Low Voltage Range Edition Brochure Revised 07/ 2012 COMPANY PROFILE Aberdare s, a member of the Powertech Group, is a leading African manufacturer of cables and electrical accessories, with seven manufacturing
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More informationINTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.
INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn
More informationABOUT US ABOUT US 1 CRANE CABLES
ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its
More informationSINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V
LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable
More informationP Low Voltage Catalogue Cables Australia Powering your Project
P +61 8 9367 8978 Low Voltage Catalogue Cables Australia Powering your Project CABLES AUSTRALIA PTY LTD LOW VOLTAGE CATALOGUE ABOUT US Cables Australia is a locally owned and operated distributor of high
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationNotes 3 Explanatory Information 4-10
Low Voltage Cables Section Three SECTION THREE - LOW VOLTAGE CABLES PAGE Notes 3 Explanatory Information 4-10 Construction 4 Current Ratings 5 Rating Factors 6 Voltage Drops 8 Selection Procedures 10 Minimum
More informationÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE
LIFT & CRANE CABLE Reference Quick Select Chart 132 Crane Cable Installation Instructions 133 Lift Cable Installation Instructions 134 ÖLFLEX ÖLFLEX CRANE NSHTÖU 135 Reelable Cable for Low to Medium Mechanical
More informationENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable
ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for
More informationChapter 6. WIRING SYSTEMS Safe Electrical Design
Chapter 6 WIRING SYSTEMS Safe Electrical Design Topic 6-3 CABLE SELECTION BASED ON CURRENT CARRYING CAPACITY REQUIREMENTS INSTALLATION CONDITIONS Current carrying capacity (CCC) is the maximum continuous
More informationOFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS
OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationArmoured Power and Control Cables to BS7917
1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit
More information1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)
WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,
More informationArmoured Power and Control Cables Fire Resistant
Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity
More informationHow to order. Payment options. Delivery options. Online acatalog. By phone + (44) By fax + (44)
S P E C I A L I S T C A B L E S U P P L I E R S How to order Online / acatalog By phone + (44) 1628 850024 By fax + (44) 1628 648068 By email info@csecables.com Our hours Monday to Friday, 8am-5.30pm Payment
More informationCores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.
()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More informationINSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES
THE SAFE APPLICATIO OF CABLES The cables manufactured by S are only appropriate for the transmission of electric energy for supply and signalling purposes. First of all the valid construction and installation
More informationTechnical Specification. for 1.1 KV Copper Control Cable
WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,
More informationSUBMERSIBLE PUMP CABLES
12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum
More informationElectric cables. Cranes
Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions
More informationArmoured Power and Control Cables to BS6883
Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in
More informationRHEYFIRM (RS)-FLAT R-(N)TSFLCGCWOEUS with / without optical fibre elements 3.6/6 kv up to 8.7/15 kv in line with DIN VDE 0250 part 813
with / without optical fibre elements 3.6/6 kv Contents: Letter code Construction details and voltage-classes Technical data 1 with / without optical fibre elements Letter code Flexible cables acc. to
More informationWelding Cables Rubber Insulated
Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications
More informationFLEXIBLE MULTI CORE CABLES
FLEXIBLE MULTI FTM Series...22 MTSV Series...23 TW-T Series...24 PF Series...25 OD Series... 27 HD Series...28 MLG2 Multi Series...30 HO Plus Series...32 HR Series... 34 HRP Series...36 FX Series... 37
More informationWire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits
Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a
More informationSelection table for flat & ribbon cables
Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationkv: medium voltage reeling cable with fibreoptics
PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy
More informationHigh Temperature Flexible Control Cable
High Temperature Flexible Control Cable 0 High Temperature Flexible Control Cable SILFLEX UL/CSA UL/CSA/CE 0 High Temperature Silicone Control Cable with UL/CSA SILFLEX SiHF CE 0 High Temperature Silicone
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More information6419X Conduit Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10
6419X Conduit Cable Application: Industrial and commercial wiring, these cables are intended for installation in trunking and conduit. They may also be used inside fixed, protected installations such as
More informationH07RN-F BS EN Flexible Rubber Cable
H07RN-F BS EN 50525-2-21 Flexible Rubber Cable Eland Product Group: A6G and A5G APPLICATION These cables are designed to provide high flexibility and have the capacity to withstand weather, oil/grease,
More informationFlexitime! Our flexible cables save you time and money.
Flexitime! Our flexible cables save you time and money. We re flexible so you won t have to be. With our improved range of flexible cables we ve brought flexibility to a completely new level. From now
More informationScreened servo cable with PUR outer sheath for highly dynamic power chain application - certified
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and
More informationCABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES
CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationCY CONTROL FLEXIBLE PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED
PVC INSULATED / TINNED COPPER WIRE BRAID (TCWB) / PVC SHEATHED ISSUE DATE: 04/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11 Plain Annealed Flexible Copper Conductors / PVC Insulated / Tinned
More informationCables. Cables. Power. Fire Resistant WILSON CABLES PRIVATE LIMITED. Distributed By :
Power Cables Fire Resistant Cables Distributed By : WILSON CABLES PRIVATE LIMITED 142, Gul Circle, Jurong Industrial Estate, Singapore 629602 Tel : + 65 68617888 Fax : + 65 68617871 E-mail : exports@wilson-cables.com.sg
More informationFault location on power cables. Fault location on power cables
Fault location on power cables Fault location on power cables Contents: 1. Introduction 2. Construction of power cables 3. Cable faults 1. Introduction Fault location on communication and power cables
More informationProduct information. Marine, Oil & Gas.
Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded
More informationTPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT
TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type
More information11-SDMS-03 REV. 02 SPECIFICATIONS FOR
11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice
More informationJULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.
FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared
More informationSY CONTROL FLEXIBLE PVC INSULATED, BEDDED AND SHEATHED WITH GALVANISED STEEL BRAID
ISSUE DATE: 05/02/2016 PAGE: 1 Manufactured generally to BS EN 50525-2-11:2011 Plain Annealed Flexible Copper Conductors / PVC Insulated / PVC Bedding / GSWB (Galvanised Steel Wire Braid) / PVC Sheathed.
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationWIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable
05 63 Technical information 64 Primary Wire 66 Brake Cable & Portable Extension Cable 67 SXL & Bonded Wire WIRE & CABLE FILS ET CÂBLES 68 Trailer Cable 70 Battery Cable 71 Welding Cable 72 Booster Cable
More informationStandard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables
Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240
More informationContent HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...
Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control
More informationSPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET
INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION
More informationGeneral Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables
Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office
More informationMarine Cables General Catalogue
Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes
More informationContents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12
Mining Cables Contents Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12 Type 241 and 241SF 14 Type 245SF 16 Type
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More informationMGVCL/MM/ /2082/11KV AB CABLE TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES
TECHNICAL SPECIFICATION FOR 11KV AERIAL BUNCHED CABLES FOR OVERHEAD LINES 1. Qualifying Requirement of AB Cable Manufacture/Supplier The manufacturer should have manufactured, successfully type tested
More informationHigh Temperature Flexible Control Cable OLFLEX
High Temperature Flexible Control Cable 6 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-60-Main Office: (60) 88-900-Outside Local Area: (800) 8-900-www.stevenengineering.com
More informationXLPE CABLE (33KV) September Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED
XLPE CABLE (33KV) September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN: U40101WB2007SGC113474;
More informationMEDIUM VOLTAGE
WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent
More informationA NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES
A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker
More informationArmoured Instrumentation Cables to BS6883
Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring
More informationTECHNICAL SPECIFICATION FOR 11KV, 3C x95mm mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED)
TECHNICAL SPECIFICATION FOR 11KV, 3C x95mm 2 + 80mm 2 AERIAL BUNCHED CABLES FOR OVERHEAD LINES (CROSSED LINKED POLYTHENE DRY GAS CURED) 1. SCOPE This specification covers requirements of, 3C x95mm 2 +
More informationHYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor
HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY Exclusive Authorised UK Distributor Technical Data Trademark Type designation Specification Application HYDROFIRM(T)
More informationTRAXLINE CABLES FOR MOTION
TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables
More informationRAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø
RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)
More information2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties
2. CONDUCTORS 2.1 Strand Types 2.1.1 Concentric Strand 7 2.1.2 Bunch Strand 7 2.1.3 Rope Strand 8 2.1.4 Sector Conductor 8 2.1.5 Segmental Conductor 8 2.1.6 Annular Conductor 8 2.1.7 Compact Strand 8 2.1.8
More informationInstallation Recommendations
Installation Recommendations Cable pulling recommendations The process of pulling electrical cables on board marine vessels is a relatively standard procedure. Nevertheless, NEXANS would suggest the following
More informationCOMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD
PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is
More informationVOLUME - 4 (GENERAL TECHNICAL SPECIFICATIONS)
TENDER DOCUMENT NIT No. DLI/C&E/WI-665/535R FOR Tender for Supply of 3CX185 mm2, 11 KV (UE) grade, Power Cable for Augmentation of Raw Material Handling Receipt and Handling Facilities with new OHP Part
More informationTri-Rated Flexible PVC Equipment Wire
Application: High temperature, flame retardant wire designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier
More informationSpec wire. Performance Wire and Cable
Spec 44.55.99wire Performance Wire and Cable 44 Wire Dual Wall 150ºC rated, XL-PVDF SPEC 44 wire has a dual wall construction which combines the outstanding physical and electrical characteristics of radiation
More informationTIGER BRAND MINING CABLES
TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation
More informationEXTRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C
Page 1 of 24 ETRUDED, CROSS-LINKED FLUOROPOLYMER INSULATED WIRES AND CABLES ON SILVER-PLATED COPPER CONDUCTOR, LOW FREQUENCY, 600V, -100 TO +200 C ESCC Detail Specification Issue 4 March 2013 Document
More informationTHE WORLD OF LAPP. Cables for power chains
THE WORLD OF LAPP Cables for power chains Tested to breaking (or making) point The new generation of premium cables for highly dynamic applications in power chains is growing ÖLFLEX SERVO FD/CHAIN New
More informationDLO Flexible Power Cable
Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C
More informationHYDROFIRM (T) Cables. for use in Ground Water and Drinking Water
HYDROFIRM (T) Cables for use in Ground Water and Drinking Water Finely stranded copper conductor EPR insulation Special synthetic rubber sheath Until now, the renowned HYDROFIRM TGK cables were available
More informationEDS LV WAVEFORM MAINS CABLE RATINGS
Document Number: EDS 02-0033 Network(s): Summary: ENGINEERING DESIGN STANDARD EDS 02-0033 LV WAVEFORM MAINS CABLE RATINGS EPN, LPN, SPN This standard details the technical and practical information required
More informationTo keep your family safe and protected V-Guard Wires & Cables
The Suraksha Chakra To keep your family safe and protected V-Guard Wires & Cables Efficient Performance For over four decades V-Guard lived up to the reputation of making reliable products that were designed
More informationAirport Cables & Connectors
Airport Cables & Connectors Aircraft Cable & Connector Products Descrip on 0 Hz Single Jacket No Contact Sec on 0 Hz Single Jacket With Replaceable Durable Hard Nose Contact Sec on 0 Hz Single Jacket -
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of
More informationMedium Voltage YOUR ENERGY, OUR SYSTEMS, ANYWHERE
Medium Voltage YOUR ENERGY, OUR SYSTEMS, NYWHERE Contents Introduction 3 Cable Components 4 Cable Handling 7 Product Codes 8 Health, Safety and Environment 9 Exploded Cable View 11 Copper 1.9/3.3kV 12
More informationSECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.
SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The
More informationT E C H N I C A L D A T A for
Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU
More informationWire and Cable. 55 Wire Single or Dual Wall 200ºC rated, XLETFE High performance wire and cable. Features & Benefits
55 wire is insulated with modified radiation crosslinked ETFE polymer and combines the easy handling of a flexible thin wall wire, with excellent scrape abrasion and cut-through characteristics. The single
More informationREPORT OF PERFORMANCE TIC
REPORT OF PERFORMANCE TIC 1580-13 OBJECT TYPE Three-core power cable 18/30(36) kv, 3x500 mm2, 2XWY(P)-FR XLPE Rated voltage, U 0/U (U m) 18/30 (36) kv Conductor material Cu Conductor cross-section 3x500
More informationPOLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL. ESCC Detail Specification No.
Page 1 of 23 POLYIMIDE INSULATED WIRES AND CABLES, LOW FREQUENCY, 600V, -200 TO +200 C BASED ON TYPE SPL ESCC Detail Specification Issue 3 May 2013 Document Custodian: European Space Agency see https://escies.org
More informationParamount Communications Ltd., part of the Paramount Cables Group. started up as a small- scale cable unit more than 60 years ago and
INDUSTRIAL CABLES Paramount Communications Ltd., part of the Paramount Cables Group started up as a small- scale cable unit more than 60 years ago and became one of the nation s leading cables manufacturing
More informationRHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814
HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD(RTS)
More informationGUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.
GUXW Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection 05--0 v5.0 Ordering Information Belden Part Numbers Fibre Description / count
More informationEDS KV TRIPLEX CABLE RATING
Document Number: EDS 02-0027 Network(s): Summary: EPN, LPN, SPN ENGINEERING DESIGN STANDARD EDS 02-0027 11KV TRIPLEX CABLE RATING This engineering design standard provides the cable ratings and important
More informationRHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814
HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD
More informationList Price w.e.f. 02nd January, 2018
w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables
More informationRailway products. Edition 2014
Railway products Edition 2014 Bridging our technologies Interdisciplinary knowledge The HUBER+SUHNER Group is a leading international manufacturer of electrical and optical interconnectivity components
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More informationCoax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3
Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging
More informationInnovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability
Introduction Innovative Eldra Solar Cabling System Eldra is an innovative company of international standing. A fast growing, ambitious business offering a broad range of high quality products and with
More informationSTANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4
Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked
More information