T E C H N I C A L D A T A for

Size: px
Start display at page:

Download "T E C H N I C A L D A T A for"

Transcription

1

2 Page 2 of 33 T E C H N I C A L D A T A for Electrical, Instrumentation and Communication Offshore LIST OF CONTENT: RFXU 0,6/1KV, BLACK SHEATH, UNARMOURED...4 CONSTRUCTION...4 RANGE AND DIMENSIONS RFXU 0,6/1kV...5 ELECTRICAL DATA...5 INSTALLATION DATA...5 RFOU 0,6/1KV, BLACK, ARMOURED, FLAME RETARDANT...6 CONSTRUCTION...6 RANGE AND DIMENSIONS RFOU 0,6/1kV...7 ELECTRICAL DATA...7 INSTALLATION DATA...8 BFOU 0,6/1KV, BLACK, ARMOURED, FIRE RESISTANT...9 CONSTRUCTION...9 RANGE AND DIMENSIONS BFOU 0,6/1 kv...10 ELECTRICAL DATA...10 INSTALLATION DATA...11 UX 600V, YELLOW/GREEN, TYPE G...12 CONSTRUCTION...12 RANGE AND DIMENSIONS UX 600V...13 ELECTRICAL DATA...13 INSTALLATION DATA...13

3 Page 3 of 33 BFOU (I+C) 250V, GREY (NIS), BLUE (IS), ARMOURED...14 CONSTRUCTION...14 RANGE AND DIMENSIONS BFOU (i+c) 250V, Grey (NIS)...15 RANGE AND DIMENSIONS BFOU (i+c) 250V, Blue (IS)...15 ELECTRICAL CHARACTERISTICS...16 INSTALLATION DATA...16 BFXU (I+C) 250V, GREY (NIS), BLUE (IS), UNARMOURED...17 CONSTRUCTION...17 RANGE AND DIMENSIONS BFXU (i+c) 250V, Grey (NIS)...18 RANGE AND DIMENSIONS BFXU (i+c) 250V, Blue (IS)...18 ELECTRICAL CHARACTERISTICS...18 INSTALLATION DATA...19 QFCI OPTICAL FIBER CABLE, ORANGE SHEATH, ITEM BOSTRIG MHV SINGLE CONDUCTOR CABLE, ITEM 40, 41, BOSTRIG MHV THREE CONDUCTOR CABLE, ITEM CONDUCTOR BUILT-UP AND RESISTANCE, IEC TESTS METHODS FOR ALL CABLE COMPONENTS IN THE RFOU, RFXU, BFOU AND BFXU CABLES...25 INSTALLATION RECOMMENDATIONS...26 STANDARD WOODEN DRUM...27 STANDARD WOODEN DRUM...27 STANDARD WOODEN DRUM, PACKED, WITH LAGGING...28 PREPARATION FOR SHIPMENT...29 UNPACKING PROCEDURE...29 SHIPPING AND STORAGE RECOMMENDATIONS...29 HANDLING OF CABLE DRUMS...30 Tightening...30 Rolling of drums...30 Lifting...30 Stacking...31 Inner Cable End...31 Temperature...31 Direction of spooling...32 Cutting...32 Transport - road/rail...32 CODE DESIGNATION...33

4 Page 4 of 33 RFXU 0,6/1kV, Black sheath, Unarmoured Flame retardant cables RFXU 0,6/1kV Halogen-free Maximum operating Conductor temperature Operating voltage Uo/U : 85 O C : 0,6/1kV Application Fixed installation for power, control and lighting in safe areas, general purposes. Standards applied IEC: IEC: /A IEC: ,2 IEC: ,2 IEEE:45/383 -Design guidelines -Flame retardance -Halogen-free properties - Low smoke properties - Flame retardance CONSTRUCTION CODE LETTER Conductor Tinned, annealed, stranded copper. (1) Insulation R EP-rubber. (2) Bedding F Flame retardant halogen-free thermoset compound. (3) No armour X No armour Impregnated glass-tape and rubberrized nylontape (4) Outer sheath U Flame retardant halogen-free thermoset compound. (5) Marking Colour E.g; meter year of manufacture Draka Norsk Kabel RFXU 0,6/1kV 1 400mm² IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Black. meter is for reference lenght only. Additional tapes may be applied. Core identification: One core Black

5 Page 5 of 33 RANGE AND DIMENSIONS RFXU 0,6/1kV Item number No. of cores and cond. area mm² Cond. Diam. Appr. Insulation mm Diameter over bedding Diameter overall Weight of cable approx. kg/km 47 1 X ,2 2,4 29,0±1,5 33,0±2, X ,6 2,6 32,0±2,0 36,0±2, X ,6 2,9 36,0±2,0 40,5±2, X ,0 3,1 39,5±2,0 44,5±2, ELECTRICAL DATA No. of cores x cross section Conductor resistance [Ω/km] Reactance [Ω/km] Impedance [Ω/km] at 85 C Continous current rating Ampere Short circuit [Ampere] [mm2] at 20 C at 85 C at 60 Hz at 60 Hz at 25 C 1 sec 0,3 sec 1x 240 0,0762 0,0957 0,107 *) 0, x 300 0,0607 0,0762 0,106 *) 0, x 400 0, ,0596 0,104 *) 0, x 500 0,0369 0,0463 0,103 *) 0, *) Reactance for 1-conductor cables given at three-foil formation Correction factors for different ambient temperatures: Ambient temperature C Rating factors 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 INSTALLATION DATA TYPE [mm 2 ] Overall Diameter [] Minimum bending radius During Fixed installation installed (mm) (mm) Maximum pulling tension [N] 1x ,0±2, x ,0±2, x ,5±2, x ,5±2, Minimum installation temperature: - 20 C

6 Page 6 of 33 RFOU 0,6/1kV, Black, Armoured, Flame retardant Flame retardant cables RFOU 0,6/1kV Halogen-free Maximum operating Conductor temperature Operating voltage Uo/U : 85 O C : 0,6/1kV Application Fixed installation for power, control and lighting in both EXand safe areas, general purposes. Standards applied IEC: IEC: /A IEC: ,2 IEC: ,2 IEEE:45/383 - Design guidelines - Flame retardance - Halogen-free properties - Low smoke properties - Flame retardance CONSTRUCTION CODE LETTER Conductor Tinned, annealed, stranded copper. (1) Insulation R EP-rubber. (2) Bedding F Flame retardant halogen-free thermoset compound. (3) PETP-tape (4) Armour O Tinned copper wire braid. (5) PETP-tape and rubberized nylon-tape. (6) Outer sheath U Flame retardant halogen-free thermoset compound. (7) Marking (example) Colour meter is for reference length only. meter year of manufacture DRAKA NORSK KABEL RFOU 0,6/1kV 3 4mm² FLEX-FLAME IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Black. Core identification: One core Black Two cores Black - Offwhite Three cores Black - Red Blue Four cores Black - Red Blue - Offwhite Five cores and above Black number on Offwhite base Neutral Offwhite

7 Page 7 of 33 RANGE AND DIMENSIONS RFOU 0,6/1kV Item number No. of cores and cond. area mm² Cond. Diam. Appr. Insulation mm Diameter over bedding Diameter overall Weight of cable approx. kg/km 64 2 X 4/6 2,6 1,1 12,0±1,0 16,0±1, X 2,5/6 2,0 1,0 11,5±1,0 15,0±1, X 4/6 2,6 1,1 13,0±1,0 17,0±1, X 6/6 3,2 1,1 14,5±1,0 18,5±1, X 10/10 4,1 1,2 17,0±1,0 21,0±1, X 16/16 5,2 1,3 20,0±1,5 24,5±1, X 25/16 6,6 1,4 23,0±1,5 28,0±1, X 50/25 9,1 1,6 30,0±2,0 36,0±2, X 70/35 10,7 1,7 35,0±2,0 41,0±2, X 95/50 12,6 1,9 39,5±2,0 46,5±2, , 52 3 X 120/60 14,2 2,0 44,0±2,5 51,0±3, x 150/70 * 15,9 2,1 48,0±2,5 57,5±3, X 185 ** 48 3 X 300 *** 62 4 X 4/6 2,6 1,1 14,5±1,0 18,5±1, X 50/25 9,1 1,6 33,0±2,0 39,0±2, X 95/50 12,6 1,9 44,0±2,5 51,0±3, *) This cable has a double braid (two layers of copper braids) **) Instead of the 3 core 185 mm² we offer a parallell connection with 2 cables 3 core 70/35 mm² (as item 55) **) Instead of the 3 core 300 mm² we offer a parallell connection with 2 cables 3 core 95/50 mm² (as item 54) ELECTRICAL DATA No. of cores x cross section Conductor resistance [Ω/km] Reactance [Ω/km] Impedance [Ω/km] at 85 C Continous current rating Ampere Short circuit [Ampere] [mm2] at 20 C at 85 C at 60 Hz at 60 Hz at 25 C 1 sec 0,3 sec 2x 4/6 4,70 5,90 0,118 5, x 2,5/6 7,56 9,49 0,123 9, x 4/6 4,70 5,90 0,118 5, x 6/6 3,11 3,91 0,111 3, x 10/10 1,84 2,31 0,106 2, x 16/16 1,16 1,46 0,102 1, x 25/16 0,734 0,921 0,098 0, x 50/25 0,391 0,491 0,094 0, x 70/35 0,270 0,339 0,092 0, x 95/50 0,195 0,245 0,091 0, x 120/60 0,154 0,193 0,090 0, x 150/70 0,126 0,158 0,089 0, x 4/6 4,70 5,90 0,118 5, x 50/25 0,391 0,491 0,094 0, x 95/50 0,195 0,245 0,091 0,

8 Page 8 of 33 Correction factors for different ambient temperatures: Ambient temperature C Rating factors 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 INSTALLATION DATA TYPE [mm 2 ] Overall Diameter [] Minimum bending radius During Fixed installation installed (mm) (mm) Maximum pulling tension [N] 2x 4/6 16,0±1, x 2,5/6 15,0±1, x 4/6 17,0±1, x 6/6 18,5±1, x 10/10 21,0±1, x 16/16 24,5±1, x 25/16 28,0±1, x 50/25 36,0±2, x 70/35 41,0±2, x 95/50 46,5±2, x 120/60 51,0±3, x 150/70 57,5±3, x 4/6 18,5±1, x 50/25 39,0±2, x 95/50 51,0±3, Minimum installation temperature: - 20 C

9 Page 9 of 33 BFOU 0,6/1kV, Black, Armoured, Fire resistant Fire resistant cables BFOU 0,6/1kV Halogen free Maximum operating Conductor temperature Operating voltage Uo/U : 85 O C : 0,6/1kV Application Fixed installation for power,control and lighting in both EXand safe areas, emergency and critical systems. Standards applied IEC: IEC: /A IEC: ,2 IEC: ,2 IEC:60331 IEEE:45/383 - Design guidelines - Flame retardance - Halogen-free properties - Lowskome properties - Fire resistance - Flame retardance CONSTRUCTION CODE LETTER Conductor Tinned, annealed, stranded copper. (1) Insulation B Mica-tape (2) / EP-rubber. (3) Bedding F Flame retardant halogen-free thermoplastic compound. (4) PETP-tape (5) Armour O Tinned copper wire braid. (6) PETP-tape and rubberized nylon-tape (7) Outer sheath U Flame retardant halogen-free thermoset compound. (8) Marking (example) Colour E.g; meter year of manufacture DRAKA NORSK KABEL BFOU 0,6/1kV 3 2,5/6mm² IEC IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Black. meter is for reference length only. Core identification: Three cores Black Red Blue Four cores Black Red Blue - Offwhite 5 cores and above Black numbers on Offwhite base Neutral Offwhite

10 Page 10 of 33 RANGE AND DIMENSIONS BFOU 0,6/1 kv Item number No. of cores and cond. area mm² Cond. Diam. Appr. Insulation mm Diameter over bedding Diameter overall Weight of cable approx. kg/km Copper content approx. kg/km 70 3 X 4/6 2,6 1,1 14,0±1,0 17,5±1, X 6/6 3,2 1,1 15,0±1,0 19,0±1, X 10/10 4,1 1,2 17,5±1,0 22,0±1, X 16/16 5,2 1,3 20,5±1,5 25,5±1, X 25/16 6,6 1,4 24,0±1,5 28,5±1, X 2,5/4 2,0 1,0 11,5±1,0 15,0±1, X 2,5/6 2,0 1,0 13,0±1,0 17,0±1, X 2,5/6 2,0 1,0 18,0±1,0 22,0±1, X 2,5/10 2,0 1,0 21,0±1,5 25,5±1, X 2,5/16 2,0 1,0 29,5±1,5 34,5±2, X 2,5/25 2,0 1,0 42,5±2,5 49,0±2, * We offer 12 core 2,5 mm² instead of 8 core 2,5 mm² ELECTRICAL DATA No. of cores x cross section Conductor resistance [Ω/km] Reactance [Ω/km] Impedance [Ω/km] at 85 C Continous current rating Ampere Short circuit [Ampere] [mm2] at 20 C at 85 C at 60 Hz at 60 Hz at 25 C 1 sec 0,3 sec 3x 4/6 4,70 5,90 0,123 5, X 6/6 3,11 3,90 0,115 3, X 10/10 1,84 2,31 0,110 2, X 16/16 1,16 1,46 0,105 1, X 25/16 0,734 0,921 0,098 0, X 2,5/4 7,56 9,49 0,107 9, X 2,5/6 7,56 9,49 0,107 9, X 2,5/6 7,56 9,49 0,107 9, X 2,5/10 7,56 9,49 0,107 9,492 14, X 2,5/16 7,56 9,49 0,107 9, X 2,5/25 7,56 9,49 0,107 9,492 8, Correction factors for different ambient temperatures: Ambient temperature C Rating factors 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79

11 Page 11 of 33 M inimum bending radius During Fixed stallation in installed (mm) (mm) Maximum pulling tension [N] 3x 4/6 17,5±1, X 6/6 19,0±1, X 10/10 22,0±1, X 16/16 25,5±1, X 25/16 28,5±1, X 2,5/4 15,0±1, X 2,5/6 17,0±1, X 2,5/6 22,0±1, X 2,5/10 25,5±1, X 2,5/16 34,5±2, X 2,5/25 49,0±2, Minimum installation temperature: - 20 C

12 Page 12 of 33 UX 600V, Yellow/Green, Type G Flame retardant conductors UX 600V Halogen-free Maximum operating conductor temperature Operating voltage Uo/U : 85 O C : 600V Application Insulated conductor for earthing and bonding services. Standards applied IEC: IEC: IEC: /A IEC: ,2 IEC: ,2 IEEE: 45/383 - Design guidelines - Flame retardance - Flame retardance - Halogen-free properties - Low smoke properties - Flame retardance CONSTRUCTION CODE LETTER Conductor Tinned, annealed, stranded copper. (1) Rubberized nylon-tape (2) Insulation U Flame retardant halogen-free thermoset compound. (3) Unsheathed X Marking Example meter year of manufacture DRAKA NORSK KABEL UX 600V 1 x 70 mm² FLEX-FLAME IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Colour Yellow/Green meter is for reference length only.

13 Page 13 of 33 RANGE AND DIMENSIONS UX 600V Item number No. of cores and cond. area mm² Cond. Diam. Appr. Insulation mm Diameter overall Weight of cable approx. kg/km Copper content approx. kg/km 77 1 x 6 3,2 1,1 6,0±0, x 16 5,2 1,3 8,5±0, x 35 7,7 1,5 11,5±1, x 70 10,9 1,7 15,0±1, ELECTRICAL DATA No. of cores x cross section Conductor resistance [Ω/km] Reactance [Ω/km] Impedance [Ω/km] at 85 C Continous current rating Short circuit [Ampere] [mm2] at 20 C at 85 C at 60 Hz at 60 Hz at 25 C 1 sec 0,3 sec 1 x 6 3,11 3,91 N/A N/A x 16 1,16 1,46 N/A N/A x 35 0,529 0,664 N/A N/A x 70 0,270 0,339 N/A N/A N/A = not applicable Correction factors for different ambient temperatures: Ambient temperature C Rating factors 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 INSTALLATION DATA TYPE [mm 2 ] Overall Diameter [] Minimum bending radius During Fixed installation installed (mm) (mm) Maximum pulling tension [N] 1 x 6 6,0±0, x 16 8,5±0, x 35 11,5±1, x 70 15,0±1, Minimum installation temperature: - 20 C

14 Page 14 of 33 BFOU (I+C) 250V, Grey (NIS), Blue (IS), Armoured Fire resistant cable Individual pair screen and overall screen BFOU(i+c) 250V Halogen-free Maximum operating conductor temperature Operating voltage : 85 O C : 250V Application Standards applied Fixed installation for instrumentation, communication, control, alarm, emergency and critical systems in both EXand safe areas. CONSTRUCTION IEC: IEC: /A IEC: ,2 IEC:60331 IEC: ,2 IEEE: 45/383 - Design guidelines - Flame retardance - Halogen-free properties - Fire resistance - Low smoke properties - Flame retardance CODE LETTER Conductor Tinned annealed, stranded copper (1) Insulation B Mica-tape (2) /EP-rubber. (3) Twinning Colour coded, cores twisted together and wrapped with polyester tape. Pairs / triples are laid up and individual screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pair / triples are identified by numbered tape. PETP-tape (4) Overall Laminated Cu/PETP-tape with tinned flexible copper drain wire. (5) Bedding F Flame retardant halogen-free thermoplastic compound. (6) Armour O PETP-tape (7) Tinned copper wire braid. (8) PETP-tape and rubberized nylon-tape. (9) Sheath U Flame retardant halogen-free thermoset compound. (10) Marking (example) Colour meter is for reference length only E.g; meter year of manufacture DRAKA NORSK KABEL BFOU(I+C) 250V 8 PAIR 1,5 mm² IEC IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Grey or Blue Pair/trippel identification: Pair Black Offwhite Triple Black - Offwhite Red Additional tapes may be applied.

15 Page 15 of 33 RANGE AND DIMENSIONS BFOU (i+c) 250V, Grey (NIS) Item number No. of pairs and conductor area mm² Cond. Diam. approx Insulation Bedding mm Diameter over bedding Armour wire Outer sheath mm Diameter overall Weight of cable Approx kg/km Copper content approx kg/km 2 4 pair 0,75 1,1 0,8 1,2 14,5±1,0 0,25 1,4 19,0±1, pair 1,0 1,3 0,8 1,1 9,0±0,8 0,20 1,1 12,5±1, pair 1,0 1,3 0,8 1,2 16,0±1,0 0,25 1,5 20,5±1, pair 1,5 1,6 0,8 1,1 9,5±0,8 0,20 1,2 13,0±1, pair 1,5 1,6 0,8 1,2 15,0±1,0 0,25 1,4 19,0±1, pair 1,5 1,6 0,8 1,3 17,5±1,0 0,25 1,5 22,0±1, pair 1,5 1,6 0,8 1,5 28,0±1,5 0,30 1,9 33,0±2, pair 1,5 1,6 0,8 1,7 38,5±2,0 0,40 2,3 44,5±2, pair 2,5 2,0 0,8 1,1 10,5±1,0 0,20 1,2 14,0±1, triple 1,5 1,6 0,8 1,1 10,5±1,0 0,20 1,2 14,0±1, triple 1,5 1,6 0,8 1,2 16,5±1,0 0,25 1,5 20,5±1, triple 1,5 1,6 0,8 1,4 23,0±1,5 0,30 1,8 28,0±1, triple 1,5 1,6 0,8 1,5 31,0±2,0 0,30 2,0 36,0±2, The coverage density of the braided armour are minimum 90% in acc. with IEC RANGE AND DIMENSIONS BFOU (i+c) 250V, Blue (IS) Item number No. of pairs and conductor area mm² Cond. Diam. approx Insulation Bedding Mm Diameter over bedding Armour wire Outer sheath mm Diameter overall Weight of cable Approx kg/km Copper content approx kg/km 1 4 pair 0,75 1,1 0,8 1,2 14,5±1,0 0,25 1,4 19,0±1, pair 1,0 1,3 0,8 1,1 9,0±0,8 0,20 1,1 12,5±1, pair 1,0 1,3 0,8 1,2 16,0±1,0 0,25 1,5 20,5±1, pair 1,5 1,6 0,8 1,1 9,5±0,8 0,20 1,2 13,0±1, pair 1,5 1,6 0,8 1,2 15,0±1,0 0,25 1,4 19,0±1, pair 1,5 1,6 0,8 1,3 17,5±1,0 0,25 1,5 22,0±1, pair 1,5 1,6 0,8 1,5 28,0±1,5 0,30 1,9 33,0±2, pair 1,5 1,6 0,8 1,7 38,5±2,0 0,40 2,3 44,5±2, pair 2,5 2,0 0,8 1,1 10,5±1,0 0,20 1,2 14,0±1, triple 1,5 1,6 0,8 1,1 10,5±1,0 0,20 1,2 14,0±1, triple 1,5 1,6 0,8 1,2 16,5±1,0 0,25 1,5 20,5±1, triple 1,5 1,6 0,8 1,4 23,0±1,5 0,30 1,8 28,0±1, triple 1,5 1,6 0,8 1,5 31,0±2,0 0,30 2,0 36,0±2, The coverage density of the braided armour are minimum 90% in acc. with IEC

16 Page 16 of 33 ELECTRICAL CHARACTERISTICS Type Capacitance approx. nf/km Inductance approx. mh/km Resistance at 20 C max. Ohm/km L/R ratio H/ohm Single pair 0, ,75 24,8 15,12 Single pair/triple 1, ,68 12,2 27,87 Single pair 2, ,70 7,56 46,3 Each individually shielded pair/triple has these characteristics INSTALLATION DATA TYPE [mm 2 ] Overall Diameter [] Minimum bending radius During Fixed installation installed (mm) (mm) Maximum pulling tension [N] 4 pair 0,75 19,0±1, pair 1,0 12,5±1, pair 1,0 20,5±1, pair 1,5 13,0±1, pair 1,5 19,0±1, pair 1,5 22,0±1, pair 1,5 33,0±2, pair 1,5 44,5±2, pair 2,5 14,0±1, triple 1,5 14,0±1, triple 1,5 20,5±1, triple 1,5 28,0±1, triple 1,5 36,0±2, Minimum installation temperature: - 20 C

17 Page 17 of 33 BFXU (I+C) 250V, Grey (NIS), Blue (IS), Unarmoured Fire resistant cable Individual pair screen and overall screen BFXU(i+c) 250V Halogen-free Application Maximum operating conductor temperature Operating voltage Standards applied : 85 O C : 250V Fixed installation for instrumentation, communication, control, alarm, emergency and critical systems in both EXand safe areas. CONSTRUCTION IEC: IEC: /A IEC: ,2 IEC:60331 IEC: ,2 IEEE: 45/383 - Design guidelines - Flame retardance - Halogen-free properties - Fire resistance - Low smoke properties - Flame retardance CODE LETTER Conductor Tinned annealed, stranded copper (1) Insulation B Mica-tape (2) /EP-rubber. (3) Twinning Colour coded, cores twisted together and wrapped with polyester tape. Pairs / triples are laid up and individual screened by copper backed polyester tape with tinned copper drain wire. Each pair/triple is wrapped with polyester tape to prevent electrical contact with adjacent pairs/triples. Pair / triples are identified by numbered tape. PETP-tape (4) Overall Laminated Cu/PETP-tape with tinned flexible copper drain wire. (5) Bedding F Flame retardant halogen-free thermoplastic compound. (6) No Armour X Impregnated glass-tape and rubberized nylon-tape. (7) Sheath U Flame retardant halogen-free thermoset compound. (9) Marking (example) Colour meter is for reference length only E.g; meter year of manufacture DRAKA NORSK KABEL BFXU(I+C) 250V 8 PAIR 1,5 mm² IEC IEC /A Cold bend(-40 deg. C) / Cold impact(-35 deg. C) CE Grey or Blue Additional tapes may be applied. Pair/trippel identification: Pair Black Offwhite Trippel Black - Offwhite Red

18 Page 18 of 33 RANGE AND DIMENSIONS BFXU (i+c) 250V, Grey (NIS) Item number No. of pairs and conductor area mm² Cond. Diam. approx Insulation Bedding mm Diameter over bedding Outer sheath mm Diameter overall Weight of cable Approx kg/km Copper content approx kg/km 29 1 pair 1,5 1,6 0,8 1,1 9,5±0,8 1,1 12,5±1, pair 1,5 1,6 0,8 1,2 15,0±1,0 1,4 18,0±1, pair 1,5 1,6 0,8 1,5 28,0±1,5 1,8 32,0±2, triple 1,5 1,6 0,8 1,1 10,5±1,0 1,1 13,0±1, triple 1,5 1,6 0,8 1,2 16,5±1,0 1,4 19,5±1, triple 1,5 1,6 0,8 1,4 23,0±1,5 1,7 27,0±1, The coverage density of the braided armour are minimum 90% in acc. with IEC RANGE AND DIMENSIONS BFXU (i+c) 250V, Blue (IS) Item number No. of pairs and conductor area mm² Cond. Diam. approx Insulation Bedding Mm Diameter over bedding Outer sheath mm Diameter overall Weight of cable Approx kg/km Copper content approx kg/km 28 1 pair 1,5 1,6 0,8 1,1 9,5±0,8 1,1 12,5±1, pair 1,5 1,6 0,8 1,2 15,0±1,0 1,4 18,0±1, pair 1,5 1,6 0,8 1,5 28,0±1,5 1,8 32,0±2, triple 1,5 1,6 0,8 1,1 10,5±1,0 1,1 13,0±1, triple 1,5 1,6 0,8 1,2 16,5±1,0 1,4 19,5±1, triple 1,5 1,6 0,8 1,4 23,0±1,5 1,7 27,0±1, The coverage density of the braided armour are minimum 90% in acc. with IEC ELECTRICAL CHARACTERISTICS Type Capacitance approx. nf/km Inductance approx. mh/km Resistance at 20 C max. Ohm/km L/R ratio H/ohm Single pair/triple 1, ,68 12,2 27,87 Each individually shielded pair/triple has these characteristics

19 Page 19 of 33 INSTALLATION DATA TYPE [mm 2 ] Overall Diameter [] Minimum bending radius During Fixed installation installed (mm) (mm) Maximum pulling tension [N] 1 pair 1,5 12,5±1, pair 1,5 18,0±1, pair 1,5 32,0±2, triple 1,5 13,0±1, triple 1,5 19,5±1, triple 1,5 27,0±1, Minimum installation temperature: - 20 C

20 Page 20 of 33 QFCI optical fiber cable, Orange sheath, item 27 Optical cable for indoor and outdoor use in vital communication and emergency systems that need to be operational during fire. The cable has a patented design that ensures operation for more than 3 hours in fires up to 1000ºC. The cable is halogen free and flame retardant to protect against secondary damage to electronic equipment during and after fire. Outer sheath is made from black UV-stabilized and weather resistant material and may be exposed for shorter periods to fluids such as diesel, petrol, glycol, etanol, white spirite and ASTM oil 2. The resistance to these fluids is according to DOD-STD-1678, method 8030.The cable is reinforced with a steel wire braiding. The fibres are protected in jelly filled loose tubes stranded around a central strength member to ensure optimum performance and long life. Each fibre and loose tube is colour coded for easy identification during splicing and termination. The outer sheath is marked to show fibre type and cable type. Fire resistant cable QFCI Indoor and outdoor Fire resistant Flame retardant and halogen free Loose tube Fibres in mica wrapped loose tube Steel strength element Wrapping Inner sheath Filler Steel wire braiding Wrapping Outer sheath Weight and dimensions Number of fibres Number of fibres in each tube Number of tubes + fillers Loose tube diameter (mm) Outer diameter (mm) Weight (kg/km) Heat release (MJ/km) Other fibre counts are available on request. Cable properties Tensile strength (IEC E1) Max tensile load during installation Max tensile load during operation 1500 N 500 N Temperature window Operation Installation Storage -30 C to +60 C -10 C to +60 C -40 C to +70 C Crush (IEC E3) 3000 N/10cm Fire and smoke classifications Impact (IEC E4) 20 impacts, 5J IEC (750 C, 3 hours) <1 db excess loss Torsion (IEC E7) Cable bending Minimum bending diameter Cable bend (IEC E11) ±1 turn/1m 250 mm <0.1dB/ ±5 turn Upgraded IEC (1000 C, 3 hours) BP-236 IEC IEC cat. A and C IEC IEC <1.5 db excess loss

21 Page 21 of 33 Optical fibres Fibre type 62.5/125 FDDI Core diameter 62.5 ± 3.0 µm Mode field diameter Cladding diameter 125 ± 2.0 µm Primary coating 250 µm diameter (nominal) Attenuation 850 nm 3.2 db/km 1300 nm 0.9 db/km 1310 nm 1550 nm Bandwidth 850 nm 1300 nm >200 MHz km >500 MHz km Dispersion nm 1550 nm Numerical aperture ± Minimum permanent bending diameter 50 mm

22 Page 22 of 33 Bostrig MHV Single conductor cable, item 40, 41,42 Bostrig MHV-15(LS)BS : Single Conductor Power (Type L Jacket & Sheath) 15kV (IEC 8.7/15 kv) Shielded 100% Level Armored and Sheathed Application: Bostrig MHV-15(LS)BS single conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODU s and platforms where flame retardant cables having excellent physical and electrical properties are required. These cables have excellent resistance to oils, abrasion, petrochemical fluids, moisture and sunlight. Conductor: Soft annealed tinned copper. Stranding shown in the data table in pdf file embedded below. Conductor Shield: Semi-comnducting tape with extruded thermosetting semi-conducting EPR. Insultation: Extruded thermosetting EPR, 90 C-Type E. Thicknesses shown in the data table in the pdf file embedded below. Insulation Shield: Extruded thermosetting semi-conducting XLPO. Metallic Braid Shield: Tinned copper braided shield, 85% coverage. Jacket and Sheath: Both the inner jacket applied over the metallic braid and the outer sheath over the armor is flame retardant, Low Smoke Zero Halogen chemically crosslinked polyolefin (XLPO). Thicknesses shown in the data table in the pdf file embedded below. Armor: Braided Bronze. Tests: Meets applicable test requirements in IEC 60502, IEC , IEEE & 1993 (draft), ICEA S , UL 1072, J-120 and flame test in IEC 332-2, cat A, A/F. Rating: Listed by a Nationally Recognized Testing Laboratory, (NRTL) in conformance to IEC 60502, IEC , UL 1072 and ICEA S Cable meets the performance requirements of IEEE % 1993 (draft). Type approved by DNV, ABS and LRS. Bostrig MHV-15(LS)BS data sheet: Double Click to Open: MHV 15kVLS(IEC8,7 15kV).pdf

23 Page 23 of 33 Bostrig MHV Three conductor cable, item 43 Bostrig MHV3-15BS(LS) : Three Conductor Power (Type L Jacket & Sheath) 15kV (IEC 8.7/15 kv) Shielded 100% Level Armored and Sheathed Application: Bostrig MHV3-15(LS)BS single conductor 15,000 volt shielded cables are suitable for use in commercial marine applications, MODU s and platforms where flame retardant cables having excellent physical and electrical properties are required. These cables have excellent resistance to oils, abrasion, petrochemical fluids, moisture and sunlight. are also available with either a fully insulated grounding conductor or an un-insulated grounding conductor evenly distributed in the interstices of the cable. Conductor: Soft annealed tinned copper. Stranding shown in the data table in pdf file embedded below. Conductor Shield: Semi-comnducting tape with extruded thermosetting semi-conducting EPR. Insultation: Extruded thermosetting EPR, 90 C-Type E. Thicknesses shown in the data table in the pdf file embedded below. Insulation Shield: Extruded thermosetting semi-conducting XLPO. Metallic Braid Shield: Tinned copper braided shield, 85% coverage. Jacket and Sheath: Both the inner jacket applied over the metallic braid and the outer sheath over the armor is flame retardant, Low Smoke Zero Halogen chemically crosslinked polyolefin (XLPO). Thicknesses shown in the data table in the pdf file embedded below. Armor: Braided Bronze. Tests: Meets applicable test requirements in IEC 60502, IEC , IEEE & 1993 (draft), ICEA S , UL 1072, J-128 and flame test in IEC 332-2, cat A, A/F. Rating: Listed by a Nationally Recognized Testing Laboratory, (NRTL) in conformance to IEC 60502, IEC , UL 1072 and ICEA S Cable meets the performance requirements of IEEE % 1993 (draft). Type approved by DNV, ABS and LRS. Bostrig MHV3-15(LS)BS data sheet: Double Click to Open: MHV3 15kVLS(IEC8,7 15kV).pdf

24 Page 24 of 33 CONDUCTOR BUILT-UP and RESISTANCE, IEC Conductor resistance, tinned copper 250V and 0,6/1kV. In accordance with IEC 60228, class 2. Tinned stranded copper conductors for single core and multicore cables 250V and 0,6/1kV Nom. cond. area mm² No. of wires and diameter of wires mm Approx. diam. Max. resistance pr km 20 C 85 C ohm ohm 0,5 7x 0,30 0,9 36,7 46,1 0,75 7x 0,37 1,1 24,8 31,1 1 7x 0,43 1,3 18,2 22,8 1,5 7x 0,53 1,6 12,2 15,3 2,5 7x 0,67 2,0 7,56 9,49 4 7x 0,85 2,6 4,70 5,90 6 7x 1,05 3,2 3,11 3, x 1,35 4,1 1,84 2, x 1,71 5,2 1,16 1, x 2,13 6,6 0,734 0, x 1,53 7,7 0,529 0, x 1,80 9,1 0,391 0, x 2,17 10,9 0,270 0, x 1,80 12,6 0,195 0, x 2,03 14,2 0,154 0, x 2,27 15,9 0,126 0, x 2,52 17,7 0,100 0, x 2,24 20,2 0,0762 0, x 2,52 22,6 0,0607 0,0762

25 Page 25 of 33 Tests methods for all Cable Components in the RFOU, RFXU, BFOU and BFXU cables 1. Acid Gas Emission tested according to MIL-C paragraph Halogen Content tested according to IEC Smoke Index tested according to NES Toxicity Index tested according to NES 713 Table of Test results (representing project not to exceed values) 1) % HCl 2) Halogen Content 3) Smoke Index Notes 1 & 2 4) Toxicity Index Insulation 0.5 % 0.5 % approx Fillers 0.5 % 0.5 % Bedding 0.5 % 0.5 % Sheath (Halogenfree) 0.5 % 0.5 % < Notes 1. The smoke index value of the insulation is higher due to the compound components used to impart flame retardant properties to the material. 2. The smoke index values of the fillers, bedding and sheathing materials are higher than specified in MIL-C due to the low-temperature requirements for White Rose (-40 C cold bend, -35 C cold impact, CSA C22.2 No.38-95).

26 Page 26 of 33 INSTALLATION RECOMMENDATIONS Minimum cable bending radius, RFXU,RFOU, BFXU and BFOU, 250V and 0,6/1kV cables. The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than: 6 times the external diameter of cable when fixed installed 8 times the external diameter of cables during installation Installations temperature, RFXU,RFOU, BFXU and BFOU, 250V and 0,6/1kV cables.. Minimum recommendated temperature of installations: - 20 C for RFXU, RFOU, BFXU and BFOU cables C for QFCI optical fiber cable Storage conditions, RFXU,RFOU, BFXU and BFOU, 250V and 0,6/1kV cables.. Extended storage conditions on the site can be estimated to at least two years. The cable-ends always have to be sealed to stop ingress of moisture. Note: One turn of the cable have to be scrapped if the cable end not have been sealed. Minimum cable bending radius, Bostrig MHV(LS) cables. The internal radius of cable bends which are not subjected to movements by expansion, is not to be less than: 6 times the external diameter of cable for unarmoured and sheathed cables 8 times the external diameter of armoured and sheathed cables Installations temperature, Bostrig MHV(LS) cables. Minimum recommendated temperature of installations: - 40 C for MHV cables. Storage conditions, Bostrig MHV(LS) cables. Extended storage conditions on the site can be estimated to at least two years. The cable-ends always have to be sealed to stop ingress of moisture. Note: One turn of the cable have to be scrapped if the cable end not have been sealed.

27 STANDARD WOODEN DRUM Page 27 of 33 Flanges, 2-ply (spruce) Center hole Barrel Bolts for reinforcing Material Flanges Barrel Center hole : spruce : 2-ply, 90 cross grain : reinforced with through-going bolts : each drum has a center hole (spindle)

28 Page 28 of 33 STANDARD WOODEN DRUM, PACKED, WITH LAGGING Sealed cable end Lagging Hoop-iron 1. Lagging is nailed to the drum or 3 hoop-irons are applied over the lagging to ensure the tightness to the drum. 3. The sealed inner cableend is coming out through the flange, which makes it possible to test the cable on the drum. 4. The drum may be lifted by forklift truck, or through the center hole.

29 Page 29 of 33 PREPARATION FOR SHIPMENT 1. After inspection and testing withnessed by COMPANY's representative the cable ends are sealed. The cable is packed on our standard wooden drums and lagged. 2. The cable drums are marked in accordance with instructions given in the Purchase Order documents. 3. Both cable ends are free, (the inner end comes out through the drum flange) and the cable can thus be tested while still on drum. UNPACKING PROCEDURE 1. Remove the hoop-irons, they are not nailed to the lagging. 2. Remove the lagging, which is nailed to the drum flanges. 3. The cable is now ready to be pulled. SHIPPING AND STORAGE RECOMMENDATIONS The drums may be lifted by forklift truck or through the center hole. The drums must be stored in the upright position, small drums may be stored in two layers, use stoppers at the end of the bottom row. The drums may be sent by rail, ship or air. During shipment the drums are prevented from starting rolling by placing (wooden) stoppers underneath by the flanges, like this:

30 Page 30 of 33 HANDLING OF CABLE DRUMS Although genereally tough, cables can be damaged by impact, pinching or abrasion. Payoff spooling shall be an easy operation. Through faulty handling cables may slide or "crawl". This can result in pinching or locking and cause damage. Tightening Due to changing weather conditions or transport, wooden drums may slightly shrink or loosen which necessitates retightening of the flange nuts. Rolling of drums To prevent cable "crawl", drums must be rolled in the same direction as the cable has been laid up on the drum from the factory. This is especially when the wooden lagging has been removed. Care must be taken when drums are rolled against each other, specially when cardboard protection is used, or if wooden lagging has been removed. Lifting When using wires or ropes for lifting, they must be parallell to the flanges to prevent inward pressure. (Use spreader.) When using a fork lift truck the forks must be applied across the flanges and have sufficient reach. Drums must be lowered gently, not dropped.

31 Page 31 of 33 Stacking Drums MUST be stacked or stored STANDING on the flanges, not lying flat. Wood chocks should be placed onder the flanges to prevent accidental rolling. When stacking it is essential to have the flanges meet, particulaly with heavy drums. When cardboard protection is used, stacking should be avoided. Inner Cable End Normally the inner end protrudes through one of the flanges. It is well protected on leaving the factory, but may protrude somewhat because of its stiffness. Special care must therefor be taken to prevent damage by lifting tackle, drums or other objects, and to prevent the protruding end from causing damages to its surroundings. Temperature Handling and spooling of cables must only take place within the specified temperature range (as specified in contracts, sales documents, manuals etc.) The cable needs time to adjust to changes in temperature. It is estimated that a full cable drum needs about 24 hours to adjust to a temperature change of 20 C.

32 Page 32 of 33 Direction of spooling The cable must be drawn off the drum AGAINST the direction the cable has been laid up on the drum. Cutting When cut, the exposed cable ends must be taped or otherwise sealed off to keep out moisture. Transport - road/rail The drums must be secured by suitable wooden wedges pressed under the flanges and nailed to the floor.

33 CODE DESIGNATION Page 33 of 33 This code designation covers the norwegian cables RFXU, RFOU, BFXU, BFOU and QFCI and it does not cover the Bostrig MHV cables. EPR = EPDM - ethylene propylene rubber MICA HF/FR SHF1 SHF2 - Mica Glass Tape - Halogenfree thermoplastic or thermoset compound (filling compound) - Flame retardant halogen-free thermoplastic compound According to IEC , type SHF1 - Flame retardant halogen-free thermoset compound According to IEC , type SHF2 Materials Mica/EPR EPR Optical fibre in loose tube HF/FR (filling Compound) (BF- and RF-cables) Armour, Galvanized Steel Wire Braid Armour, Tinned Copper Wire Braid No armour SHF1 sheath SHF2 sheath ( up to and including 36kV) 1.Letter: 2.Letter: 3.Letter: 4.Letter: Insulation Bedding/ Braid/ Outher Sheath Armour Sheath B R Q F C O X I U Additional abbreviation for instrumentation cables: Collective screen cable... (c) Individual pair/triple sceened cable... (i)

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS OFFSHORE CABLES GENERAL CATALOGUE Offshore Cables technergy INTEGRATED CABLING SOLUTIONS TM 1 TEOF Offshore Cables INTEGRATED CABLING SOLUTIONS TM technergy Introduction Every offshore platform requires

More information

CIR (Crush & Impact Resistant) VFD Power Cable

CIR (Crush & Impact Resistant) VFD Power Cable 37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per

More information

Armoured Power and Control Cables to BS7917

Armoured Power and Control Cables to BS7917 1 Armoured Power and Control Cables to BS Fire Resistant, TAC. MGT. EPR. ZH. GSWB. SW, 00/00 V. Low Smoke Zero Halogen Application Armoured cables for fixed wiring in ships and offshore units where circuit

More information

GEXOL WORLD CLASS OIL & GAS CABLES

GEXOL WORLD CLASS OIL & GAS CABLES GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant

More information

Armoured Power and Control Cables Fire Resistant

Armoured Power and Control Cables Fire Resistant Armoured Power and Control Cables Fire Resistant Low Smoke Zero Halogen TAC. MGT. EPR. ZH. GSWB. SW, 00/00V Application Armoured cables for fixed wiring in ships and offshore units where circuit integrity

More information

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...

More information

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant

More information

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc. ()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical

More information

Product information. Marine, Oil & Gas.

Product information. Marine, Oil & Gas. Product information Marine, Oil & Gas www.drakamog.com DRAKA Product information MOG 2010 Draka ShipLine range; the choice for reliability and flexibility For more than 100 years, Draka has met and exceeded

More information

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic

More information

Armoured Instrumentation Cables to BS6883

Armoured Instrumentation Cables to BS6883 Armoured Instrumentation Cables to BS Low Smoke Zero Halogen Pairs/Triples - Collectively Screened. TAC, EPR, SCRN, SW, GSWB, SW 0/0V Application Armoured control and instrumentation cables for fixed wiring

More information

kv: medium voltage reeling cable with fibreoptics

kv: medium voltage reeling cable with fibreoptics PROTOLO(SMK)-LWL ()TSKCGEWOEU 3,6/6 kv: medium voltage reeling cable with fibre-optics Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy

More information

Armoured Power and Control Cables to BS6883

Armoured Power and Control Cables to BS6883 Armoured Power and Control Cables to BS Low Smoke Zero Halogen Single-Core - T.A.C EPR, SW, TPBWB. SW 00/00 V Multicore - T.A.C EPR, SW, GSWB, SW 00/00 V Application Armoured cables for fixed wiring in

More information

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4

Ship Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4 Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T

More information

COPPER + LWL RAW CABLES

COPPER + LWL RAW CABLES COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation

More information

Kerman & Kavian Cable Industries ( KCI )

Kerman & Kavian Cable Industries ( KCI ) KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman

More information

ABOUT US ABOUT US 1 CRANE CABLES

ABOUT US ABOUT US 1 CRANE CABLES ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its

More information

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C

More information

Ship and Offhsore. Approved cables for ship- and offshoreindustry

Ship and Offhsore. Approved cables for ship- and offshoreindustry Ship and Offhsore Approved cables for ship- and offshoreindustry NEK Kabel AS - Norway. (NEK Sealine Marine products) tel. +47 67 91 21 80 - Firmapost@nek-kabel.no 1 OVER 100 YEARS OF EXPERIENCE 1913-2013

More information

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum

More information

SUPERIOR MARINE CABLE SOLUTIONS

SUPERIOR MARINE CABLE SOLUTIONS SUPERIOR MARINE CABLE SOLUTIONS FLEXIBLE FINE STRANDED Horizon Maximus II Company Profile Through over 35 years of history and experience, we have built a renowned reputation for supplying superior cables

More information

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5.

GUXW. Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection v5. GUXW Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor, Steel Wire Armor (SWA) A/I-VQ(ZN)HBH Full Rodent Protection 05--0 v5.0 Ordering Information Belden Part Numbers Fibre Description / count

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2

Data sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2 Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded

More information

Ø 1250 * 688 mm 93 kg ± 105m

Ø 1250 * 688 mm 93 kg ± 105m GCDE Multi Loose Tube Cables Universal Indoor / Outdoor - Corrugated Steel Tape Armor (CST) A/I-DQ(ZN)H(SR)H Full Rodent Protection 05-05-5 v7.0 Ordering Information Belden Part Numbers Fibre Description

More information

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft

Data sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology

More information

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

DLO Flexible Power Cable

DLO Flexible Power Cable Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable...................................... 2-3 n Type W Cables Type W 1/C Motor Lead Cable.................................... 4-5 Type W 2/C

More information

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker

More information

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation

More information

K20 & L120 LSZH Armoured F/FTP Cat6 Cables

K20 & L120 LSZH Armoured F/FTP Cat6 Cables K20 & L120 LSZH Armoured F/FTP Cat6 Cables The cables are designed for high speed data transmissions, and are suitable for installations in cable trays or on hooks. RATP CAT6-K20 (for K20 cable) FRANCE

More information

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft

Data sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic

More information

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications. Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001 Industrial Ethernet Petrol Forecourt Cable (Solid) 3014P24S1001-10 Industrial Ethernet OPT cable manufactured for Petrol Forecourt Applications.

More information

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum.

JULY Standards are finally approved by the Standards High Council of Iranian Ministry of Petroleum. FOREWORD This Standard is intended to be used within and for Iranian Ministry of Petroleum (N.I.O.C, N.I.G.C, N.P.C., N.I.O.R.D.C. and other affiliate organizations and companies) and has been prepared

More information

Electric cables. Cranes

Electric cables. Cranes Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions

More information

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable

ENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for

More information

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...

Content HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications... Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control

More information

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like

More information

MEDIUM VOLTAGE

MEDIUM VOLTAGE WWW.GENERGYCABLE.COM 800-308-1330 TM MEDIUM VOLTAGE MEDIUM VOLTAGE ASSEMBLIES Type SH Medium Voltage Power Cable Assemblies are designed for heavy-duty MV applications that require temporary or permanent

More information

Installation Recommendations

Installation Recommendations Installation Recommendations Cable pulling recommendations The process of pulling electrical cables on board marine vessels is a relatively standard procedure. Nevertheless, NEXANS would suggest the following

More information

Marine Cables General Catalogue

Marine Cables General Catalogue Marine Cables General Catalogue Marine Cables Special cables for civil and defence ship applications General catalogue Linking the Future As the worldwide leader in the cable industry, Prysmian Group believes

More information

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D

Optical Fiber Jelly. PBT loose tube. PE shealth. Aramid Yarn SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D SINGLE MODE OPTICAL FIBER ITU-T REC. G.652D Product Model: GYFXTY 2~12C Our Ref: No.TS-FT201107-03-64-V1.0 GENERAL 1.1 These optical cables have excellent protection, optical transmission and mechanical

More information

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

11-SDMS-03 REV. 02 SPECIFICATIONS FOR 11-SDMS-03 REV. 02 SPECIFICATIONS FOR XLPE INSULATED POWER CABLES FOR RATED VOLTAGES FROM 15 KV UP TO 36 KV (U m ) This specification is property of SEC and subject to change or modification without notice

More information

Ø560*336mm 4.25 kg 2100 ± 105m

Ø560*336mm 4.25 kg 2100 ± 105m GUMT Mini-Breakout Cables (Distribution) Universal Indoor/ Outdoor A/I-VQ(ZN)H Standard Rodent Protection 05-0-0 v3.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM

More information

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø

RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)

More information

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables

Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES. 11 kv XLPE-Insulated Three-Core Underground Cables Standard Technical Specifications for Electrical Works CABLES AND ACCESSORIES ( Data Sheets ) 11 kv XLPE-Insulated Three-Core Underground Cables (3x240 mm 2 ) ADWEA/ADDC/AADC STANDARD : D-AAA-CAB-11-3Cx240

More information

Information technology. Generic cabling systems, General requirements

Information technology. Generic cabling systems, General requirements KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.

More information

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS

Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION BUILDING MANAGEMENT SYSTEMS Multimedia Specials DATA CABLES FOR INDUSTRIAL, BUILDING & BROADCAST APPLICATIONS INDUSTRIAL COMMUNICATION SOLUTIONS COAXIAL CABLES BUILDING MANAGEMENT SYSTEMS BROADCASTING & STUDIO Prysmian Group Linking

More information

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY. INTRODUCTION Nuhas Oman LLC, an integral part of The Al Bahja Group of Companies, is a Quality producer of: HV, MV and LV Cables Enamelled Copper Wires Oxygen Free Continuous Cast Copper Wire Rods Drawn

More information

Outdoor, CCTV or CCTV, Fig 8 Armored.

Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor, CCTV or CCTV, Fig 8 Armored. Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet,

More information

Mongoose PT Platform Shale Shaker

Mongoose PT Platform Shale Shaker Mongoose PT Platform Shale Shaker (UL VERSION) Revision: A By: MT Mongoose Platform Page 1 of 10 NOTE: Mongoose PT Platform Shale Shaker The attached is a reference to M-I SWACO s STANDARD Mongoose Platform

More information

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Direct Burial Application (SM 12 Fibers) Product: Single Mode Optical Fiber Cable Customer: Date: Write by: Kevin Zhou / technical engineer International

More information

NETWORK CONNECTIVITY SYSTEMS

NETWORK CONNECTIVITY SYSTEMS NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation

More information

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits

GAAG. Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)2Y(T) v4.0. Ordering Information. Applications. Features & Benefits GAAG Multi Loose Tube Cables Outdoor - ADSS A-DQ(ZN)Y(T) 05-04-9 v4.0 Ordering Information Belden Part Numbers Fibre Description / count 4 8 8 4 30 36 6.5/5-OM GAAG04 GAAG08 GAAG GAAG8 GAAG4 GAAG30 GAAG36

More information

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE LIFT & CRANE CABLE Reference Quick Select Chart 132 Crane Cable Installation Instructions 133 Lift Cable Installation Instructions 134 ÖLFLEX ÖLFLEX CRANE NSHTÖU 135 Reelable Cable for Low to Medium Mechanical

More information

TIGER BRAND MINING CABLES

TIGER BRAND MINING CABLES TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation

More information

Selection table for flat & ribbon cables

Selection table for flat & ribbon cables Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON

More information

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516

More information

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES

CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective

More information

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4

STANDARD SPECIFICATION FOR INSTRUMENT CABLES AND RELATED ACCESSORIES DOCUMENT NO : 44-LK /J.02/0014-A4 Page 1 of 12 STANDARD SPECIFICATION FOR INSTRUMENT CABLES DOCUMENT NO : 44-LK-5100-00/J.02/0014-A4 Rev No. Issue Date Pages Rev Description Prepared A 12-08-08 12 Issued for Comments / Approval By Checked

More information

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram

OpDAT Universalkabel 1x4 OM4 - biegeunempfindlich, Klasse. Principle diagram Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification installation cable U-DQ(ZN)BH universal fiber optic cable for indoors/outdoors with central or

More information

Outdoor, Fig 8 Armored, Multi Tube

Outdoor, Fig 8 Armored, Multi Tube Outdoor, Fig 8 Armored, Multi Tube Outdoor stranded Fig 8 Armored, Fiber optic cable for aerial installation. It support application such as IEEE802.3, 10G Ethernet, Gigabit Ethernet, Fast Ethernet, Ethernet,

More information

Welding Cables Rubber Insulated

Welding Cables Rubber Insulated Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications

More information

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET INDEPENDENT POWER TRANSMISSION OPERATOR S.A. TNPRD/ SUBSTATION SPECIFICATION & EQUIPMENT SECTION December 2016 SPECIFICATION 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION

More information

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3

Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging

More information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information

GORN. Central Loose Tube Cables Outdoor A-DQ(ZN)B2Y Improved Rodent Protection, 1000N Permanent Load v6.0. Ordering Information GORN Central Loose Tube Cables Outdoor A-DQ(ZN)BY Improved Rodent Protection, 000N Permanent Load 05--0 v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 6 4 6.5/5-OM GORN0

More information

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09) KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications

More information

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application

TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application TECHNICAL DATA SHEET FOR Single Mode Optical Fibre Cable Duct Application (SM 24, 36, 48, 64, 96 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM L TD. / Bulgaira Date: August 1, 2012 Write

More information

Instrumentation Cables

Instrumentation Cables around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards

More information

Complete, innovative cables range for shipbuilding industry

Complete, innovative cables range for shipbuilding industry Complete, innovative cables range for shipbuilding industry Symbols Temperature Admissible ambient temperature for continuous duty operation Weather Resistance to severe weather conditions Fire Performances

More information

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş.

HES HACILAR ELEKTRİK SANAYİ VE TİC.A.Ş. Technical Specification Revision/Date:01/02.15 By S.Erol Date : 27 February 2015 Cable Type HES Cable Product Number :, Outdoor F/O Cable :FOZZXXXSLT41DYY (ZZ: fiber type G652=SD, G657 A1 = A1, G657 A2

More information

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE 177 2012 Specification for Braided 75 Ω, Mini-Series Quad Shield Coaxial Cable for CMTS and SDI cables NOTICE

More information

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments ife? No S n K P r o ble m! No? aw a proven, rugged product for harsh environments No LV AIRGUARD LV AIRGUARD Low Voltage Cables for Harsh Environments FEATURES - No Knife? No Saw? No Problem! installation

More information

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured)

1.1_KV PVC insulated PVC sheathed multicore Aluminium Cable (armoured & unarmoured) WEST BENGAL STATE ELECTRICITY DISTRIBUTION COMPANY LIMITED (A Govt. of West Bengal Enterprise) Office of the Chief Engineer, Procurement & Contracts Department Vidyut Bhavan, 4 th. floor, Bidhannagar,

More information

14 AWG 2 AWG: 600 Volt

14 AWG 2 AWG: 600 Volt INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap

More information

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded

More information

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

WIRE & CABLE. 99 Wire Low fire hazard wire and cable Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard

More information

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. SECTION 26 05 19 PART 1 - GENERAL 1.1 THE REQUIREMENT A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents. 1.2 CONTRACTOR SUBMITTALS A. The

More information

Underground System Design TADP 547

Underground System Design TADP 547 Underground System Design TADP 547 Industry Standards, Specifications and Guides Presentation 6.4 Instructor: Frank Frentzas Industry Organizations Several professional organizations develop standards

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD(RTS)

More information

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814

RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 HEAVY DUTY REELING CABLE 0.6/1 kv RHEYCORD (RTS) (N)SHTOEU-J in line with DIN VDE 0250 part 814 Contents: Letter code Construction details Cross-section and nominal voltages Technical data 2017 RHEYCORD

More information

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables

General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables Islamic Republic of Iran Vice Presidency for Strategic Planning and Supervision General Technical Specification and Execution Procedures for Transmission and Subtransmission Networks Cables NO: 452-1 Office

More information

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s

EC 200 CHARACTERISTICS D A T A S H E E T. Kabelwerk EUPEN AG cable. M e c h a n i c a l c h a r a c t e r i s t i c s EC 200 EC200 - Rev. 3-23.06.11 Characteristic impedance 50 ± 2 Material copper wire Nominal capacity (pf/m) 80.5 Construction - Relative propagation velocity (%) 83 Diameter (mm) 1.05 Inductance (µh/m)

More information

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers)

TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED. (SM 2~24 Fibers) TECHNICAL DATA SHEET FOR Uni-tube Single Mode Optical Fibre Cable ARMORED (SM 2~24 Fibers) Product: Single Mode Optical Fiber Cable Producer: XCOM LTD. / Bulgaira Date: August 1, 2012 Write by: Petar Georgiev

More information

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive

Data sheet OpDAT breakout cable 24x1 OM4 - bend insensitive Page 1/9 Illustrations Principle diagram See enlarged drawings at the end of document Product specification connection cable I-V(ZN)HH breakout cable for direct connector termination for indoors and outdoors

More information

Medium Voltage Power Cables

Medium Voltage Power Cables N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium

More information

MULTIMEDIA CABLE H6091ZHB

MULTIMEDIA CABLE H6091ZHB CAVEL News MULTIMEDIA CABLE H6091ZHB MULTIMEDIA CABLE H6091ZHB Multimedia is a must in the modern way of life. Growing communication needs in any environment whether at home or the office the connection

More information

Instrumentation Cable PLTC/ITC and TC Types

Instrumentation Cable PLTC/ITC and TC Types Instrumentation Cable PLTC/ITC and TC Types The Quality Connection 2 The Quality Connection Product range Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for

More information

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

Low Voltage AIRGUARD. A proven, rugged product for harsh environments Low Voltage AIRGUARD A proven, rugged product for harsh environments Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable

More information

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V

SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V LEDBURN CABLES IS AN INDEPENDENTLY OWNED CABLE DISTRIBUTOR. SINGLE CORE CABLE-2491X PVC H05V-K CABLE 300/500V Internal equipment wire. Also used in instrumentation panels of power switchgear. Suitable

More information

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES

INSTRUCTIONS FOR THE SAFE APPLICATION OF CABLES THE SAFE APPLICATIO OF CABLES The cables manufactured by S are only appropriate for the transmission of electric energy for supply and signalling purposes. First of all the valid construction and installation

More information

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010 (0,25mm) XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance

More information

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations CCW Continuously Corrugated Welded Cable Armored Cable for Hazardous Locations CCW Servicing Industrial and Specialty Applications This catalog contains in-depth information on the most comprehensive line

More information

Copyright June Nexans

Copyright June Nexans Nexans is the worldwide leader in the cable industry, with an industrial presence in 29 countries and commercial activities in 65 countries. Nexans brings an extensive range of advanced copper and optical

More information

List Price w.e.f. 02nd January, 2018

List Price w.e.f. 02nd January, 2018 w.e.f. 02nd January, 2018 HRFR/FR-LSH/HFFR/ PVC Insulated Industrial Cables Multicore Round PVC Cables Flat Three Core Industrial Cable for Sumersible use Telecom & Co-axial Cables LAN Cables CCTV Cables

More information

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:

Addison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction: Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.

More information

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and

More information

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits

Wire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable.   Features & Benefits Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a

More information

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.

For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y

More information

Electronically published by ABS Piraeus. Reference T , dated 30-AUG-2018.

Electronically published by ABS Piraeus. Reference T , dated 30-AUG-2018. UNTEL KABLOLARI SAYI VE TICARET ANONIM SIRKETI MAKINE OSB, 6.CAD. NO: 4 41455 DILOVASI-GEBZE KOCAELI Turkey Telephone: + 90 262 722 93 30 Fax: + 90 262 722 94 92 Email: info@untel.com.tr Web: www.untel.com.tr

More information