FieldLink MC at 20 x outer diameter Torsion
|
|
- Tabitha Lewis
- 5 years ago
- Views:
Transcription
1 Power cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC Cl.5 and Cl. 6, insulation optional of Polyolefine and PVC, wire identification V/L2, U/L1/C/L+, W/L3/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Polyvinylchloride (PVC) orange acc. to RAL / 1 kv (DIN VDE), 1000 V (UL / CSA) 4 kv 50Hz AC (wires) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to F) single, + 0 C to + 60 C (+ 32 F to F) repeated, Order number Dimensions Outer diameter LEC x (0.31) LEC x (0.38) LEC x (0.43) LEC x (0.52) LEC x (0.77) LEC x (0.93) LEC x (1.06) LEC x (1.20) LEC x (1.44) 52 LEONI
2 Power cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD S1 halogen free acc. to IEC Conductor Stranded bare copper wire acc. to IEC Cl. 6, insulation of TPE and PP, wire identification V/L2, U/L1/C/L+, W/L3/D/L-, GNYE Four wires twisted in layers with fillers in gaps Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL / 1 kv (DIN VDE), 1000 V (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min ( ft/min) at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to F) single, 20 C to + 60 C ( 4 F to F) repeated, Order number Dimensions Outer diameter LEC x (0.39) LEC x (0.46) LEC x (0.50) LEC x (0.59) LEC x (0.73) LEC x (0.87) LEC x (1.00) LEC x (1.16) LEC x (1.32) LEONI 53
3 Hybrid cable for permanent installation and flexible applications with low mechanical stress DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC Cl.5 and Cl. 6, insulation optional of Polyolefine, TPE and PVC, wire identification power: V/L2, U/L1/C/L+, W/L3/L-, GNYE, signal: black, white Signal wires: twisted to a pair, tape-wrapped foil, spinning of copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to F) single, + 0 C to + 60 C (+ 32 F to F) repeated, 54 LEONI
4 Order number Dimensions Outer diameter LEHC x (2 x 0.50) 9.6 (0.38) LEHC x (2 x 0.75) 10.0 (0.39) LEC x (2 x 1.00) 10.2 (0.40) LEHC x (2 x 1.50) 10.5 (0.41) LEHC x (2 x 0.50) 10.0 (0.39) LEHC x (2 x 0.75) 10.3 (0.41) LEHC x (2 x 1.00) 10.4 (0.41) LEHC x (2 x 1.50) 10.5 (0.41) LEHC x (2 x 0.50) 11.5 (0,45) LEHC x (2 x 0.75) 11.8 (0.46) LEHC x (2 x 1.00) 12.0 (0.47) LEHC x (2 x 1.50) 12.0 (0.47) LEHC x (2 x 1.00) 13.4 (0.53) LEHC x (2 x 1.00) 15.3 (0.60) LEHC x (2 x 1.00) 20.8 (0.82) LEHC x (2 x 1.00) 24.0 (0.94) LEHC x (2 x 1.50) 13.5 (0.53) LEHC x (2 x 1.50) 15.6 (0.61) LEHC x (2 x 1.50) 21.0 (0.83) LEHC x (2 x 1.50) 24.1 (0.95) LEHC x (2 x 1.50) 28.5 (1.12) LEHC x (2 x 1.50) 31.5 (1.24) LEHC x (2 x 1.50) 36.5 (1.44) LEONI 55
5 Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 / HD S1 halogen free acc. to IEC Conductor Stranded bare copper wire acc. to IEC Cl. 6, insulation of TPE and PP, wire identification power: V/L2, U/L1/C/L+, W/L3/D/L-, GNYE, signal: black, white Signal wire: twisted to pair, tape-wrapped foil, spinning of tinned copper wires (covering 85 %); pair and four wires twisted in layer with fillers in gaps and central filler Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min ( ft/min) at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C (-58 F to +176 F) single, 20 C to + 60 C (+ 68 F to F) repeated, 56 LEONI
6 Order number Dimensions Outer diameter LEHC x (2 x 0.50) 9.9 (0.39) LEHC x (2 x 0.50) 10.1 (0.40) LEHC x (2 x 1.00) 10.8 (0.43) LEHC x (2 x 0.50) 11.5 (0.45) LEHC x (2 x 0.75) 11.8 (0.46) LEHC x (2 x 1.00) 12.1 (0.48) LEHC x (2 x 1.50) 12.5 (0.49) LEHC x (2 x 0.50) 13.0 (0.51) LEHC x (2 x 0.75) 13.3 (0.52) LEHC x (2 x 1.00) 13.5 (0.53) LEHC x (2 x 1.50) 13.8 (0.54) LEHC x (2 x 1.00) 14.7 (0.58) LEHC x (2 x 1.00) 16.5 (0.65) LEHC x (2 x 1.00) 19.5 (0.77) LEHC x (2 x 1.00) 23.2 (0.91) LEHC x (2 x 1.50) 15.0 (0.59) LEHC x (2 x 1.50) 16.7 (0.66) LEHC x (2 x 1.50) 19.5 (0.77) LEHC x (2 x 1.50) 23.2 (0.91) LEHC x (2 x 1.00) 27.0 (1.06) LEHC x (2 x 1.50) 27.0 (1.06) LEHC x (2 x 1.00) 31.0 (1.22) LEHC x (2 x 1.50) 31.0 (1.22) LEHC x (2 x 1.50) 35.0 (1.38) LEONI 57
7 diese Zeichnungen habe ich nicht gefunden FieldLink MC Hybrid cable for permanent installation and flexible applications with low mechanical stress oil resistant acc. to DIN VDE 0281 Part 1 / HD21.1S3 Conductor Stranded bare copper wire acc. to IEC Cl.5 and Cl. 6, insulation optional of Polyolefine or PVC, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair, 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler Jacket Polyvinylchloride (PVC) orange acc. to RAL / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 5 x outer diameter (single), 20 x outer diameter (repeated) 2 m/s² (6.56 ft/s²) 30 m/min (98.43 ft/min) at 20 x outer diameter ± 30 /m ( ± 9.15 /ft) 20 C to + 80 C ( 4 F to F) single, + 0 C to + 60 C (+ 32 F to F) repeated, Order number Dimensions Outer diameter LEHC x x (2 x 0.34) 10.6 (0.42) LEHC x x (2 x 0.75) 12.0 (0.47) LEHC x x (2 x 0.75) 12.3 (0.48) LEHC x x (2 x 0.75) 13.8 (0.54) LEHC x x (2 x 1.00) 14.2 (0.56) LEHC x (2 x 1.00) + (2 x 1.50) 15.7 (0.62) LEHC x (2 x 1.00) + (2 x 1.50) 17.7 (0.70) LEHC x (2 x 1.00) + (2 x 1.50) 22.8 (0.90) LEHC x x (2 x 1.50) 23.0 (0.91) LEHC x x (2 x 1.50) 26.8 (1.06) LEHC x x (2 x 1.50) 29.5 (1.16) 58 LEONI
8 Hybrid cable for flexible installation with high mechanical stress high endurance trailing applicable DIN VDE 0282 Part 10 and VDE Part B halogen free acc. to IEC Conductor Stranded bare copper wire acc. to IEC Cl. 5 and Cl. 6, insulation of TPE and PP, wire identification power: black, white with numbers 1, 2, 3, GNYE, signal: 1st pair 5, 6, 2nd pair 7, 8 Signal wires: twisted to pairs, tape-wrapped foils, braidings of tinned copper wires (covering 85 %); pairs and four wires twisted in layer with fillers in gaps and central filler, fleece foil overlapped Jacket Thermoplastic Polyurethane (TPU) orange acc. to RAL / 1 kv for power and 24 V for signal (DIN VDE), 1000 V for power and signal (UL / CSA) Minimum bending radius allowed 6 x outer diameter (single), 12 x outer diameter (repeated) 5 m/s² (16.40 ft/s²) 180 m/min ( ft/min) at 12 x outer diameter ± 30 /m ( ± 9.15 /ft) 50 C to + 80 C ( 58 F to F) single, 20 C to + 60 C ( 4 F to F) repeated, Order number Dimensions Outer diameter LEHC x x (2 x 0.34) 10.8 (0.43) LEHC x x (2 x 0.75) 12.0 (0.47) LEHC x x (2 x 0.75) 12.4 (0.49) LEHC x x (2 x 0.75) 13.8 (0.54) LEHC x x (2 x 1.00) 15.2 (0.60) LEHC x (2 x 1.00) + (2 x 1.50) 16.7 (0.66) LEHC x (2 x 1.00) + (2 x 1.50) 18.6 (0.73) LEHC x (2 x 1.00) + (2 x 1.50) 22.5 (0.89) LEHC x x (2 x 1.50) 23.0 (0.91) LEHC x x (2 x 1.50) 25.5 (1.00) LEHC x x (2 x 1.50) 28.5 (1.12) LEONI 59
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified
Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified - Screened servo cable for high dynamic power chain application in harsh conditions with UL/CSA AWM and
More informationContinuous Flex Data Cable
1,! gti',',n Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 080--Main Office: () 88-00-Outside Local Area: (800) 8-00-www.stevenengineering.com Continuous Flex Data Cable UNITRONIC
More informationSUBMERSIBLE PUMP CABLES
12 SUBMERSIBLE PUMP CABLES 1-450 / 750 V Termoplastic rubber, round orflat flexibe cable ACCORDING TO NF C -102 HD 22.4 S2 Water absorption tests: IEC 811.1.3 VDE 0472 Teil 2 NF C -026 HD 505-1-3 s1 Maximum
More informationContent HYBRID AND SPECIAL CABLES G 1. for the application on marine engines... page. : especially for use in rail vehicles. ❿! Applications...
Content page ❿! Applications... /2 ❿! Construction examples of special cables... /3-6 ❿! S 670 PUR hybrid field bus control cable, suitable for cable tracks UL/CSA... /7 ❿! S 671 PVC hybrid field bus control
More informationDB EN valid from: Application SERVO LK SMS FX8PLUS SIGNAL
Application LAPP servo cables according to Siemens * (see footnote) Standard FX8008 PLUS SIGNAL are a new generation of very highly flexible screened signal (encoder and resolver)- cables (P/Ns 00277101
More informationLutze Inc. Flexible Control Cables USA Selection Guide V. 2.6
Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6 Lutze Inc 10 South Ridge Dr Charlotte, NC 282 Phone 0-0-0222 Fax 0-0-022 Toll free 1-800--21 www.lutze.com info@lutze.com Lutze Flexible Control
More informationBUS cable. BUS cable. Cables for use in automation- and communication technique.
Cables for use in automation- and communication technique. Industrystandards like INTERBUS-S, CAN, PROFIBUS, SINEC L2, DEVICENET and PROFINET defi ne these cables. There are also halogen free cables for
More informationServo Cable Selection
Servo Cables Servo Cable Selection Chainflex cable Jacket Shield Class Bending radius moving (factor x d) Temperature moving from/to F ( C) Oil-resistant V max. ft/s (m/s) unsupported V max. ft/s (m/s)
More informationTHE WORLD OF LAPP. Cables for power chains
THE WORLD OF LAPP Cables for power chains Tested to breaking (or making) point The new generation of premium cables for highly dynamic applications in power chains is growing ÖLFLEX SERVO FD/CHAIN New
More informationTPE-INSULATED CABLES TPE-INSULATED CABLES. Products. TPE - Cables HEW-KABEL/CDT
TPE-INSULATED CABLES Products TPE - Cables TPE-INSULATED CABLES 105 C O N T E N T S C O N T E N T S Page TPE single cores according to DIN 72551, type A 107 TPE single cores according to DIN 72551, type
More informationCoax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3
Overview Coax element HF75-0,3/1,6 RG179 HF50-0,9/2,95 RG58 HF50-0,3/0,84 RG178 Part. No. CFKoax1 CFKoax2 CFKoax3 Example drawing (see the chapter belonging to the cable for details) (see the chapter belonging
More informationCIR (Crush & Impact Resistant) VFD Power Cable
37-2 CIRVFD CIR (Crush & Impact Resistant) VFD Power Cable Gexol Insulated Three Conductor 2kV Rated 90 C UL Listed as Type TC-ER Power Conductors (x3) Soft annealed flexible stranded tinned copper per
More informationCUSTOM DESIGN COAXIAL CABLES BY SICAB
CUSTOM DESIGN COAXIAL CABLES BY SICAB. COAX RG 58 C/U Application: Coaxial Cable 50 Ohm For indoor installation as well as in industrial areas in conduits and cable ducts, for transmission of high frequency
More informationHO7RN-F 450/750V BS EN Highly Flexible Rubber Cable
Rubber Insulation and Rubber Sheathed Application Range Heavy duty flexible cables for medium mechanical stress For dry and wet applications Can be used for domestic electric tools According to HD 516
More informationCaledonian. Profibus L2 Indoor BUS CABLE. Application: Construction:
Caledonian www.caledonian-cables.co.uk www.caledonian-cables.net Profibus L2 Indoor Application: This system cable is used to interconnect L2-BUS components. This cable is an economical solution for the
More informationHigh Temperature Flexible Control Cable
High Temperature Flexible Control Cable 0 High Temperature Flexible Control Cable SILFLEX UL/CSA UL/CSA/CE 0 High Temperature Silicone Control Cable with UL/CSA SILFLEX SiHF CE 0 High Temperature Silicone
More informationINTRODUCTION PRODUCT LINES GREEN ENERGY. In drive technology, the trend is towards ever more complex
INTRODUCTION In drive technology, the trend is towards ever more complex cable systems. The quantity of data and speed of transmission are simultaneously rising rapidly. Interference-proof, fixed and dynamic
More informationSelection table for flat & ribbon cables
Just click on the products in the selection table. Click on the HELUKABEL logo at the end of the page to go back. Cables & Wires Selection table for flat & ribbon cables www.helukabel.com FLAT & RIBBON
More informationAddison. Profibus SK Indoor + Outdoor BUS CABLE. Application: Construction:
Addison www.addison-tech.com www.addison-cables.com Profibus SK Indoor + Outdoor Application: The application of these Profibus SK cables are in the cell and field area, just as for conventional types.
More informationHigh Temperature Flexible Control Cable OLFLEX
High Temperature Flexible Control Cable 6 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-60-Main Office: (60) 88-900-Outside Local Area: (800) 8-900-www.stevenengineering.com
More informationVSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)
KSXCY Series... 72 MDXCY Series... 73 HDXCY Series... 74 FDXCY Series... 76 P: (09) 264 1000 www.firstflex.co.nz KSXCY High Performance Fixed Copper Tape VSD Cable Flexible Conductors for Fixed Applications
More informationCABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES
CABLES FOR MOTION CONTINUOUS-BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS PRE-ASSEMBLED CABLES STRAIN RELIEF DEVICES FOR CABLE CARRIERS EDITION 09-2012 Durable, reliable, cost-effective
More informationABOUT US ABOUT US 1 CRANE CABLES
ABOUT US ABOUT US ÜNTEL KABLO, one of the leading cable manufacturers of Europe was established in 1972, Turkey. With almost 45 years of experience, it has been continuously developing and optimizing its
More informationExtremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488
ÖLFLEX TRAY II/TRAY II CY Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded ÖLFLEX TRAY II ÖLFLEX TRAY II CY Unshielded Construction : Finely stranded bare copper Jacket:
More informationShip Hybrid Cable DL 58 5 x UC1500 SS22 2x SM BendBright XS G.657.A2 6x MM MaxCap-BB-OM4
Wiking Ship Hybrid Cable Application Hybrid cable for shipboard applications DATA ELEMENT Primary (Campus), Secondary (Riser), Tertiary (Horizontal) IEEE 802.3: 10Base-T; 100Base-T; 1000Base-T; 10GBase-T
More informationEXTREMELY LOW MAGNETIC FIELD (ELMF) XLPE INSULATED CABLES, TYPE N2XY/FR1 0.6/1 KV
CABLE DESCRIPTION Single- or multi-phase electric cable for creating a weak external magnetic field,so as to obtain a cable wherein at last one of the conductors is assembled from two or more insulated
More informationEXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)
XTRA GUARD 1 MULTICONDUCTOR, SUPRASHIELD EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE UL TYPE CM, AWM 2464 CSA CMG FT4 300 VOLT 34 CHOOSE XTRA GUARD 1FOR: Unsurpassed Flame and Moisture Resistance
More informationHARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02
Contents Page Technical characteristics circular connector with rapid termination 50.02 Circular connector M8/M12 with rapid termination... 50.05 Han M12 panel feed-through... 50.08 Han M12 pcb adapter...
More informationRAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø
RAXLINE TPE TOP FLEXDESIGN TPE CABLES UP TO 10 MILLION MOTION CYCLES UP TO 1000 M TRAVEL LENGTH DOWN TO 5 Ø Automated Stacking Cranes (ASC) Ship To Shore Container Cranes (STS) Rubber Tyre Gantry (RTG)
More informationBUS 1010F ssa (INTERBUS Remote Bus, 2-wire) xed installation
BUS 00F (INTERBUS Remote Bus, -wire) xed installation UNIKA BUS 00F c us AWM style 79 80 C 000V FT- Conduttore Conductor Isolamento ed cazione anime Insulation and core cation Rame rosso secondo CEI EN
More informationMarineLine YOZp 0,6/1 kv
Properties Application: Light, armoured, reduced low voltage power cables for power and lighting applications in all ship areas. Characteristics: Class 2 s Light, reduced Halogen free and low smoke, flame
More informationTable of contents. Phone: Fax:
HELUKABEL GmbH Dieselstrasse 7 Hemmingen GERMANY Tel. +9 (0)750 9090 Fax.+9.(0)750.7 www.helukabel.de info@helukabel.de Created at 03/3/0 by Phone: Fax: EMail: Table of contents Page : Page 5 from. CABLES,
More informationMotor, Servo & Feedback Cables
Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature ÖLFLEX Reliable performance no matter how extreme the temperature. Choosing the best cable for applications involving extreme temperatures is one of
More informationInstrumentation Cables
around a world of cables UL INSTRUMENTATION CABLES UL THHN CABLES UL THWN CABLES Instrumentation Cables INDEX Introduction Specialty Cables 300V & 00V Instrumentation Cable Types Certificates and Standards
More information14 AWG 2 AWG: 600 Volt
INDUSTRIAL AUTOMATION & PROCESS CONTROL CABLES 18.70 600V Type MC Metal Clad and Teck-Style Cables Overview Metal Clad Interlocked PVC Outer Jacket Teck-Style PVC Outer Jacket Introduction Polyester Wrap
More informationPhoto: HELUKABEL. Motor, Servo & Feedback Cables D 1
Photo: HELUKABEL Motor, Servo & Feedback Cables D Motor, Servo & Feedback Cables A multitude of applications requires the construction of many special cables. Corresponding to the customers requirements,
More informationElectrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.
734A COAXIAL CABLE Application Intended for interconnection of transmission and switching systems equipment. Features UL listed as NEC Type CMR and CSA certified as Type CMR. NORDX/CDT 734A coaxial was
More informationSAC-5P- 1,5-PUR/M12FS SH
Extract from the online catalog SAC-5P- 1,5-PUR/M12FS SH Order No.: 1682935 Sensor/Actuator cable, 5-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end M12, on Socket, straight
More informationData sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations
Page 1/7 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12 Ethernet connection cable drag chain suitable Cat.6A, 8 pole, X-coded
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. Tougher. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. Tougher. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true
More informationElectric cables. Cranes
Electric cables. Cranes Electric cables for mobile connections. Aristoncavi spa reserve the right to modify the data in this catalogue without notice. 01/2012 Copyright Drawings and technical descriptions
More informationEcoCable and EcoFlex Cable. Smaller. Lighter. 100% Recyclable.
EcoCable and EcoFlex Cable Smaller. Lighter. 100% Recyclable. Total Performance, Completely Recyclable EcoCable and EcoFlex cable are Alpha Wire s newest innovations in control cabling. A true engineering
More informationInstallation Solutions. Cable assembly according to Siemens 6FX standard
Installation Solutions Cable assembly Siemens 6FX standard Reaching new heights in automation Contents: 1. PUR servo cable assemblies 6FX8002 without brake cores for use in cable carriers Page 4 2. PUR
More informationChallenges to automation
MOTIONLINE Challenges to automation Worldwide, there are well over a million industrial robots in operation, with over 100,000 new robots installed every year, representing some $19 billion annually, if
More informationData sheet Connection line M12 jack straight - RJ45 plug straight 4-pole, D-coded 2.0 m
Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification shielded M12-jack to RJ45-plug Ethernet connection line Cat.5, 4-pole, D-coded (IEC
More informationCores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.
()TSCGEWOEU TEAX TTS-LWL 3,6/6 kv: Application Flexible medium voltage reeling cable with integrated fibre-optics for the combined transmission of energy and data, for application under high mechanical
More informationGEXOL WORLD CLASS OIL & GAS CABLES
GEXOL WORLD CLASS OIL & GAS CABLES Severe Cold Durability Exceeds CSA Cold Bend / Cold Impact (-0 C/-35 C) Drilling Mud Resistant Flame Retardant Certified to IEC 9-3 (33-3A) and IEEE 580 Oil Resistant
More informationInstall & Go Cat.8 S/FTP Trunk Cable Assembly Description
Description Cat 8 Filler Cat.8.2 S/FTP Horizontal cables (x6) Fan-Out Cables Cat 8 STP Keystones TRUNK CABLE SECTION VIEW Assembly Isometric Front View RiT s Copper Install & Go System provides a pre-terminated
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 4P LSHF-FR, class Dca s2 d2
Page 1/7 Illustrations Principle diagram See enlarged drawings at the end of document Product specification 10 GBit installation cable, simplex installation cable Cat.7A AWG 22 S/FTP with wires shielded
More informationENERGY CORDAFLEX (SMK) (N)SHTOEU Low Voltage Reeling Cable
ENERGY (N)SHTOEU Low Voltage Reeling Cable Technical Data Type Type designation Approvals/standards Application (N)SHTOEU-J/-O DIN VDE 0250, Part 814; VDE-Reg.-Nr. 7519; GOST R Flexible reeling cable for
More informationInnovative Eldra Solar Cabling System SOLINQ total system for solar cabling Sustainability
Introduction Innovative Eldra Solar Cabling System Eldra is an innovative company of international standing. A fast growing, ambitious business offering a broad range of high quality products and with
More informationSAC-3P- 5,0-PUR/M12FR SH
Extract from the online catalog SAC-3P- 5,0-PUR/M12FR SH Order No.: 1682838 Sensor/Actuator cable, 3-position, PUR, halogen-free, Black-gray RAL 7021, shielded, Free conductor end, on Socket, angled M12,
More informationCORFLEX VFD CORFLEX VFD Part Number: Drive Cable
Part Number: Drive Cable Armored Variable Frequency Drive Cable UL Type MC HL, 600V, 90 C rated - LEAD FREE Description 3 conductor with 3 ground wires, continuous corrugated and welded, impervious aluminum
More informationTIGER BRAND MINING CABLES
TIGER BRAND MINING CABLES 5-kV TYPE SHD-GC & MP-GC -55 TYPE SHD-GC /C MOLD-CURED CPE JACKET 0 VOLTS 00% INSULATION LEVEL s Flexible tinned copper Flexible tinned copper with yellow polypropylene insulation
More informationÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary
TRAY-RATED CABLE Quick Select Chart 48 TC 600/TC 600 S 50 Flexible Tray Cable with TC-ER for Easier Installations; Unshielded & Shielded TRAY II/TRAY II CY 52 Extremely Oil-Resistant & Flexible Tray Cable
More informationInstallation Solutions. Cable assemblies according to SIEMENS 6FX standard
Installation Solutions Cable assemblies according to SIEMENS 6FX standard From products to solutions! Installation Cabinet Automation OEM Transportation Contents: 1. PUR Servo Cable Assemblies without
More informationFor information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation.
Telecommunication and fire alarm cables For information transmission at dry and moist production sites, in and under plaster, outdoors for fixed installation. J-YY Bd 14 J-YY BMK 15 J-Y(St)Y Lg 16 J-Y(St)Y
More informationData sheet MC GC1000 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft
Page 1/6 MC GC0 pro23 Cat.7 S/FTP 4P LSHF-FR 1640 ft 18427034141 Illustrations Principle diagram Product specification 10 GBit installation cable, simplex installation cable Cat.7 AWG 23 S/FTP with wires
More informationÖLFLEX HEAT. Cable Solutions for Extreme Temperature
ÖLFLEX HEAT Cable Solutions for Extreme Temperature LAPP products are available from MARYLAND METRICS P.O. Box 61 Owings Mills, MD 1117 USA ph:(10)8-10 (800)68-180 fx:(10)8-1 (800)87-99 web: http://mdmetric.com
More informationWIRE & CABLE. 99 Wire Low fire hazard wire and cable
Applications 99 wire has a dual wall construction of radiation cross-linked modified polyester. This combines excellent mechanical performance and chemical resistance with a range of enhanced fire hazard
More informationTRAXLINE CABLES FOR MOTION
TRAXLINE CABLES FOR MOTION CONTINUOUS BENDING HI-FLEX ELECTRICAL CABLES TOTALTRAX TURN-KEY SYSTEMS TRAXLINE PRE-ASSEMBLED CABLES FOR CABLE CARRIERS EDITION 5-2016 Cost-effective, reliable, durable cables
More informationIndustrial Data Solutions Industrial Ethernet Cables Category 5e DataTuff Twisted Pair Cables Heavy Duty Sunlight- and Oil-Resistant Jackets
I N D U S T R I A L C A B L E S 18.7 Cat 5e 24 AWG Bonded-Pair Solid 0.5 Bare Copper Polyethylene Insulation Industrial Grade Sunlight- and Oil-Resistant FRNC /LSNH Jacket (Black and Grey) Diaeter Noinal
More informationContents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES
Contents S / Page Technical characteristics S............................. 04.10 Technical characteristics.............................. 04.11 3 S.............................................. 04.12 3...............................................
More informationIncandescent Lampholders: Edison Screw and Bayonet Cap
: Edison Screw and Bayonet Cap Table of Contents E14 22.223 22.230 E12 22.228 22.231 [08]..10 E17 E27 22.317 [08] 12 22.318 [08] 12, 13 2010-2012 This page is only valid in connection with the general
More informationData sheet MC GC1200 pro22 Cat.7A S/FTP 2x4P LSHF-FR 1640 ft
Page 1/7 Illustrations Principle diagram Product specification 10 GBit installation cable, duplex installation cable Cat.7A AWG 22 S/FTP with wires shielded in pairs 2x4 pairs (PiMF) pair shield: plastic
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Installation Cable KS-STP Category 7 Installation Cable Certificates 10GBaseT FTP Category 6 Installation Cable UTP Category 6 Installation Cable UTP Category 5E Installation
More informationWire and Cable. 99 Wire Dual Wall 120ºC rated, Modified Polyester Low fire hazard wire and cable. Features & Benefits
Dual Wall 20ºC rated, Modified Polyester 99 wire has a dual wall construction of radiation crosslinked modified polyester. This combines excellent mechanical performance and chemical resistance with a
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 General Description: PTZ (CCTV+Control+Power) Cable, Rated-CM, 1-RG59 20 AWG solid bare copper with foam polyolefin, 95% bare copper braid, 1-22 AWG stranded
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES El Dorado, Arkansas Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology
More informationConductix-Wampfler Cables for Festoon Systems, Energy Guiding Chains & Others
Conductix-Wampfler Cables for Festoon Systems, Energy Guiding Chains & Others Cables for systems in motion selected from experts Advantage 1 Secure choice of cables Comprehension of our customers applications
More informationTwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm
name: TKF article number: 10305 description Nr.: POE- PS- 10305 PT F F F 800 B C 1 2 3 4 5 6 7 Assembly: 1. Primary tube 5 mm 2. CAT 5 E FTP cable 3. CAT 5 E FTP cable 4. Bus cable 5. Coax 9 cable 6. Separation
More informationDOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES
DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES DOWNSTREAM FACILITY CABLES Made in America CIR (Crush & Impact Resistant) CIR is a next-generation cable designed to replace older-technology cables like
More informationWelding Cables Rubber Insulated
Welding Cables Rubber Insulated C 0 V Application Primary use is for the secondary (high current) connection to automatic or hand-held metal arc welding electrodes. May also be used for non-welding applications
More informationÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE
LIFT & CRANE CABLE Reference Quick Select Chart 132 Crane Cable Installation Instructions 133 Lift Cable Installation Instructions 134 ÖLFLEX ÖLFLEX CRANE NSHTÖU 135 Reelable Cable for Low to Medium Mechanical
More informationCables and connectors for demanding connectivity solutions. LOW LOSS RF COAX CABLES single screen 75 Ω double screen 75 Ω
Cables and connectors for demanding connectivity solutions LOW LOSS RF COAX CABLES single screen 50 Ω double screen 50 Ω single screen 75 Ω double screen 75 Ω Low loss RF coax cables single screen 50 Impedance
More informationMedium Voltage Power Cables
N2XSY 6/0, /20, /30 NA2XSY 6/0, /20, /30 N2XS2Y 6/0, /20, /30 NA2XS2Y 6/0, /20, /30 N2XS(F)2Y 6/0, /20, /30 NA2XS(F)2Y 6/0, /20, /30 N2XSEY 3 x 6/0 Medium Voltage Power Cables Photo: HELUKABEL Q 47 Medium
More informationCaledonian. VG Series. Caledonian Navy Cables.
Caledonian Caledonian Navy Cables www.addison-cables.com Caledonian, established in 1978, offers one of the most complete lines of fiber and copper cabling system solutions with over hundreds of different
More informationCOPPER + LWL RAW CABLES
COPPER + LWL RAW Twisted Pair Cables... 112 TV/SAT Cables... 116 Fiber Optic Raw Cables... 120 DIGITUS CAT 7 twisted pair installation cable 4x2xAWG23 S-FTP CAT 7 1000 MHz LSZH installation cable For installation
More informationn 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible
n 0% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible Nexans AmerCable VFD CABLES CABLES Index VFD Cables Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable...
More informationVFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS
VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS INDUSTRIAL VFD CABLES Index n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable............... 2-3 Crush & Impact Resistant
More informationKerman & Kavian Cable Industries ( KCI )
KCI Kerman & Kavian Cable Industries ( KCI ) KCI Cables for control and instrumentation circuits 150/250 V (300 V) According to of IEC 60092-376 (2003) Electrical installations in ships - Part 376: Kerman
More informationVFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE
VFD CABLES 0% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE Nexans AmerCable VFD CABLES Index Standard VFD Power Cable... 2-3 Low Smoke Halogen-Free VFD Power Cable.... - 5 CIR VFD Power Cable... - 7 CIR Arctic
More informationOLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from
LAPP products are available from MARYLAND METRICS P.O. Box 261 Owings Mills, MD 21117 USA ph:(10)358-3130 (800)638-1830 fx:(10)358-312 (800)872-9329 RFQ form: http://mdmetric.com/rfq.htm Flexible Tray
More informationSection 4. Multi-Conductor
Section 4. 63 Table of Contents ÖLFLEX...66 ÖLFLEX CLASSIC 100 Flexible Power and Control Cable...67 ÖLFLEX CLASSIC 110 Flexible Control Cable Number Coded...68 ÖLFLEX CLASSIC 110 Black 1000V UV Resistant
More informationMHR-2 Two Conductor Mini High Resolution S-Video Cable
MHR- Two Conductor Mini High Resolution S-Video Cable Plenum rated Version Available MHR- Cable Two Color-Coded 6 AWG Stranded Coax Conductors Maintains signal quality and allows for easy identification
More informationDetailed Specifications & Technical Data
Description: Series 11, 14 AWG solid.064" bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond IV quad shield (60% and 40% coverage), PVC jacket Physical Characteristics
More informationY-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking
Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking A Technical data Special PVC control cables, adapted to DINVDE0 part3 Temperature range flexing -5 C ) to +0 C fixed installation
More informationDetailed Specifications & Technical Data
For more Information please call 1-800-Belden1 Description: Coax (2-1505A Type) 20 AWG BC, GIFPE isulation, Duofoil plus TC braid (95% cv.), PVC inner jackets. Pairs (4-9451 Type): 22 AWG TC, PP insul.,
More informationCommunication, Control, and Industrial Cable
Communication, Control, and Industrial Cable Specifications subject to change. For complete specifications and availability, visit www.alphawire.com. 291 Get control of demanding applications T he broad
More informationC400-UMUM-100. Jumper Assembly Sample Label. Product Classification. General Specifications. Return Loss/VSWR
C400-UMUM-100 Product Classification Brand Product Series Product Type CNT Jumper with interface types UHF Male and UHF Male, 30.48 m CNT Braided cable assembly General Specifications Body Style, Connector
More informationUNIRAIL D RS485 and BUS cables
UNIRAIL D RS485 and BUS cables Type: 1x2x22 AWG/7 + 1x22 AWG/7 (1x2x0,35 + 1x0,35) Code: RW103A stranded tinned copper wire 22 AWG/7 (0,35 mm²) white blue POWER ELEMENTS: stranded bare copper wire 22 AWG/7
More informationInformation technology. Generic cabling systems, General requirements
KRAMER WELL CONNECTED WITH KRAMER BCLS-33OR-5 Al-Mylar Conductor CAT6A F/UTP LSZH Cable Drain Wire Kramer s BCLS-33OR is a high performance CAT6A F/UTP cable designed for IT, LAN and Ethernet installations.
More information15 years of experience
Wires and Cables 15 years of experience APS supplies standard and special copper and fiber optic cables based on its 15 years of experience in the sector, 8 of which in designing and manufacturing. Since
More informationPower Cables and their Application
Power Cables and their Application Parti Materials Construction Criteria for Selection Project Planning Laying and Installation Accessories Measuring and Testing Editor: Lothar Heinhold 3rd revised edition,
More informationShielded Fire Alarm Cables
PLENUM Low-Smoke PVC JACKET UL TYPE FPLP/CMP/CL3P C(UL) CMP 300 VOLT Shielded Fire Alarm Cables Fire Alarm, Signal Monitor/Detection Audio or Control Circuits Description: Chart F, Page 41 Shielded Plenum
More informationHYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY. Exclusive Authorised UK Distributor
HYDROFIRM(T) EMV-FC S1BC4BF KTW/W270 Drinking Water Application, shielded version ENERGY Exclusive Authorised UK Distributor Technical Data Trademark Type designation Specification Application HYDROFIRM(T)
More informationMulti-Paired Cable Product Finder
Multi-Paired Cable Product Finder Technical Information NO. STRAND TYPE C00 U......................, 0 0 C000 F........................ C0 FB....................... C FB....................... C0 F.......................
More informationA NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES
A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES 2 TABLE OF CONTENTS SHIPBOARD CABLES 2 TELE-FONIKA KABLE 3 PRODUCTION POTENCIAL 5 SHIPBOARD POWER CABLES FlameBlocker KONS 0,6/1 kv 8 FlameBlocker
More information