Introducing the Agilent 7000A Triple Quadrupole GC/MS

Size: px
Start display at page:

Download "Introducing the Agilent 7000A Triple Quadrupole GC/MS"

Transcription

1 Introducing the Agilent 7000A Triple Quadrupole GC/MS Paul Zavitsanos, Joe Weitzel, Monty Benefiel and Terry Sheehan May 2008 Page 1

2 What s a Triple Quad? Page 2

3 GC/MS Triple Quad (QQQ) Collision Gas (N2 ) Ion Source Ionize Quad 1 Hexapole Collision Cell Quad 2 Detector Page 3

4 What is MRM MS/MS? Multiple Reaction Monitoring EI: many ions from the source EI-MS/MS Product 2 Q1 SIM isolate precursor before CID Product 3 Product 1 CID + Q3 filter Page 4

5 Why MS/MS? Greater Selectivity Than SIM in complex samples EI-SIM selectivity proportional to spectral resolution no selectivity against ions with same m/z interference analyte EI-MS/MS Precursor selectivity same as SIM High probability that at least one product ions will be a unique dissociation product of the precursor BUT not the interference Product 2 unit mass resolution Product 3 Product 1 interference Precursor Ion The precursor ion should NOT be used for ion ratios or quantitation since the interferences will be the same as the SIM ion Page 5

6 Why a GC/QQQ System? Allows for the selective quantitation of target compounds in high chemical background samples Better S/N in complex matrices than can be achieved by single quad approaches Newer regulations in some markets specify analytical power commensurate with GC/QQQ Page 6

7 Why a Triple? A Picture is worth a thousand words. 100 fg HCB GC/MS Single Quad SIM MS SIM MS/MS MRM GC/MS/MS QQQ MRM EI 100fg HCB in DIRTY Matrix S/N: 116:1 RMS Page 7

8 SIM vs MRM for HCB 100 fg HCB in Clean Matrix 300 fg HCB in Diesel Single MS: SIM S/N=26:1 RMS S/N=6:1 RMS MS/MS: 283.8:213.9 S/N=37:1 RMS S/N=86:1 RMS Page 8

9 Technology Agilent took the Best technologies from their industry leading 597X Series GC/MSD: Heated monolithic gold plated quartz quadrupole Proven reliable high performance source design AUTOTUNE And the Agilent 6410A LC/QQQ: Linear acceleration enhanced Collision Cell Wide Mass-Bandwidth QQQ ion optics Mass Hunter software Page 9

10 Why Proprietary Heated Quartz Gold Quads? Heated monolithic gold plated hyperbolic quartz quadrupole is the gold standard in quadrupole instruments for GC/MS High 200C temperature quadrupole operation results in greater reliability with dirty samples Virtually eliminates the need to clean quads as a maintenance issue More stable tunes and methods over a longer period of time in real world sample environments High speed MRMs (500 MRMs/sec) possible with Agilent Quad electronics AUTOTUNE Friendly!!! Page 10

11 Agilent 7000A Analyzer Page 11

12 Analyzer Details Page 12

13 High Performance Differentially Pumped Manifold N 2 (1 sccm) He (1-5 sccm) He or H 2 (1-8 sccm) CH 4 (0-2 sccm) P1 5-20E-5 Torr Source P2 8E-5 Torr Collision Cell Analyzer Rough Pump Edwards Split Flow Turbo Page 13

14 Analyzer Details Page 14

15 Analyzer Doors Open Page 15

16 Proven source performance Inert source design proven over thousands of systems in current use Stay-Clean design extends maintenance intervals with dirty samples Source tune parameters in the Autotune file Dual Filament design reduces maintenance intervals Page 16

17 EI Source Details Page 17

18 High Performance Collision Cell Design Linear acceleration design is optimized for high speed performance without ion ghosting or cross-talk MRM speed to 500 MRMs/sec allows determination of more compounds per ion group High sensitivity with wide mass bandwidth eliminates the need to tune on my your Compound for optimum sensitivity Helium seeded chemical noise reduction collision cell increases S/N. Page 18

19 Q1-Collision Cell Interface Page 19

20 Collision Cell Details (2 rods removed for clarity) Page 20

21 High performance triple off-axis detector Ultra low neutrals noise Long life and high linearity Gain calibration corrects tune file for detector age to allow repeatable long term method performance. Same design as used in the 5975 GC/MSD Page 21

22 Triple-Axis Detector hyperbolic quartz transmission quadrupole analyzer steering rod shield for secondary particles Offset Z high energy dynode Y ion beam X triple channel electron multiplier Page 22

23 Q2-Detector Interface Page 23

24 Autotune Proprietary program tunes the source, mass analyzer, and detector for (as applicable): Ion transmission Mass axis calibration Mass resolution Detector gain vs Voltage Autotune settings are saved with the method for repeatable method performance. Manual Tune override is available Page 24

25 Performance Page 25

26 Agilent 7000A 100 fg HCB Sensitivity x MRM ( > 248.9) 100fgHCB_newvial_methHCB_MRM_PW1p21p2 527N2DAC_600HeDAC_35VColE_1e7Gain_2040EMV_0Baseline_12.d Noise (RMS) = 1.99; SNR (6.387min) = :1 RMS S/N vs Spec of 100: Abundance vs. Acquisition Time (min) 1pg HCB Benchmark comparison Agilent GC/QQQ Competitor 1 >1000:1 100:1 Page 26

27 Agilent 7000A OFN Sensitivity x MRM ( > 241.0) 100fgOFN_MRM_N2DAC1160_He18p5pct_30VColE_1e7Gain_2410EMV_GaugeOff_02.d Noise (RMS) = 1.10; SNR (5.471min) = fg OFN in clean Matrix 272:241 Transition 186:1 RMS S/N Abundance vs. Acquisition Time (min) Page 27

28 Innovation that led to this level of GC/QQQ sensitivity Page 28

29 Helium Seeded Collision Cell 1 ml/min N2 Collision Gas He* + Q1 Ions In Collision Cell Ions Out He* + N 2 N He N A A +. + N 2 Page 29

30 Helium Seeded Collision Cell 1 ml/min N2 Collision Gas He* + Q1 Ions In Collision Cell Ions Out 2.5 ml/min He Buffer Gas He* + He 2He + Heat He* + N 2 N He Page 30

31 Effect of Helium Buffer Gas Tested with HCB S/N 341:1 Helium Buffer Gas OFF Page 31

32 Effect of Helium Buffer Gas tested with Hexachlorobenzene S/N 341:1 Helium Buffer Gas OFF Noise Comparison S/N 1294:1 Helium Buffer Gas ON Page 32

33 Software Page 33

34 Mass Hunter MS Workstation Software Modern software interpretation of the proven industry standard GC/MS Chemstation platform Single software Platform for all Agilent MS Systems LC/SQ, LC/QQQ, LC/TOF, LC/QTOF GC/SQ, GC/QQQ ICP/MS Page 34

35 GC/QQQ Software Modules Acquisition Analysis Excel Reporting Page 35

36 Instrument Control UI/navigation Page 36

37 QQQ Acquisition Method Editor Dialog Single window acquisition setup Page 37

38 Agilent G7000A GC/QQQ Outstanding sensitivity 100fg of OFN on column at 100:1 S/N RMS in MS/MS mode using AUTOTUNE parameters verified at customer installation amu Mass Range 500 MRM/sec Speed Reliable heated monolithic gold plated hyperbolic quadrupoles Differentially pumped vacuum system CI/NCI upgrade available New Helium seeded collision cell technology Agilent 7890 GC with Capillary Flow technology. Mass Hunter Software. Page 38

Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ

Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ ROCK SOLID Performance for Trace-Level Quantitation Agilent Technologies 1 Brief History of Agilent 6400 QQQ LC/MS 6410 2006 6460 Agilent Jet Stream

More information

Agilent 6400 Series Triple Quadrupole LC/MS System

Agilent 6400 Series Triple Quadrupole LC/MS System Agilent 6400 Series Triple Quadrupole LC/MS System Concepts Guide The Big Picture Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by

More information

Agilent 6400 Series Triple Quadrupole LC/MS System

Agilent 6400 Series Triple Quadrupole LC/MS System Agilent 6400 Series Triple Quadrupole LC/MS System Concepts Guide The Big Picture Agilent Technologies Notices Agilent Technologies, Inc. 2012 No part of this manual may be reproduced in any form or by

More information

Welcome! Denver, CO Houston, TX February 2009

Welcome! Denver, CO Houston, TX February 2009 Welcome! Denver, CO Houston, TX February 2009 Schedule & Introductions Announcements - Safety - Evaluation forms - Upcoming events > CBMSS, Feb 10 th, Nat l Jewish Center, www.cbmss.org (also Apr 22 nd

More information

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

LC/MS/MS. Page Header. triple quadrupole mass spectrometer. LC/MS/MS VARIAN, INC. 320-MS Page Header triple quadrupole mass spectrometer www.varianinc.com VARIAN, INC. 320-MS Unsurpassed commitment to innovation Varian, Inc. is an innovator and leader in mass spectrometry

More information

Ion optics innovations for increased sensitivity in hybrid MS systems

Ion optics innovations for increased sensitivity in hybrid MS systems Ion optics innovations for increased sensitivity in hybrid MS systems Abstract Sensitivity, mass resolution, scan speed, spectral fidelity, mass accuracy, and mass range are just a few of the parameters

More information

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission: Finnigan MAT 95 XP-API-GC-Trap tandem Mass spectrometer system Tandem Mass Spectrometer based on high resolution magnetic sector and Ion-Trap MS/MS system with API ( ESI, APCI ) and EI/CI ionization Mass

More information

Useful GC/MS Sensitivity for Improved Environmental Analyses. Terry L. Sheehan, Ph.D. GC/MS Senior Product Manager Santa Clara, CA 7 February 2008

Useful GC/MS Sensitivity for Improved Environmental Analyses. Terry L. Sheehan, Ph.D. GC/MS Senior Product Manager Santa Clara, CA 7 February 2008 Useful GC/MS Sensitivity for Improved Environmental Analyses Terry L. Sheehan, Ph.D. GC/MS Senior Product Manager Santa Clara, CA 7 February 2008 Definitions Sensitivity Analytical definition: slope of

More information

Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7000A Triple Quadrupole GC/MS System

Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7000A Triple Quadrupole GC/MS System Determination of the N-Nitrosamine Content in Rubber Articles Using the Agilent 7A Triple Quadrupole GC/MS System Application Note Consumer Products Authors Yun Zou and Chongtian Yu Agilent Technologies

More information

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass Spectrometers. The Ionizer, Quadrupole Mass Filter, and Detector on a Mounting Flange are designed for inclusion in your experimental

More information

N-Methyl-1-(6-methylpyridin-2-yl)propan-2-amine

N-Methyl-1-(6-methylpyridin-2-yl)propan-2-amine H C N CH HN CH. GENERAL INFORMATION IUPAC Name: CAS#: Not Available Synonyms: Source: Appearance: Not Available DEA Reference Material Collection Pale yellow powder UV max (nm): Not Determined. CHEMICAL

More information

Characterization of Common Electron Multipliers in Harsh Environments

Characterization of Common Electron Multipliers in Harsh Environments ELECTRO-OPTICS Characterization of Common Electron Multipliers in Harsh Environments The Pittsburgh Conference 2005 Poster Paper 1340-20 Bruce Laprade and Raymond Cochran BURLE Electro-Optics INC Introduction

More information

835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information

835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information 835 Vacuum Quality Monitor (VQM TM ) 2012 Brooks Automation, Inc. Proprietary Information The Revolutionary New Vacuum Quality Monitor World s Fastest, Accurate at low mass Single Gas Calibration Small

More information

SCIEX Presentation. Name of Speaker, Identification. QTRAP Functionalities. Alexandre Paccou Name of Speaker, Identification. SCIEX Presentation.

SCIEX Presentation. Name of Speaker, Identification. QTRAP Functionalities. Alexandre Paccou Name of Speaker, Identification. SCIEX Presentation. SCIEX Presentation Alexandre Paccou Name of Speaker, Identification Date SCIEX Presentation QTRAP Functionalities Hardware and Software Tipps und Tricks, Name of Speaker, Identification Date For Research

More information

A New Conjoined RF Ion Guide for Enhanced Ion Transmission

A New Conjoined RF Ion Guide for Enhanced Ion Transmission A New Conjoined RF Ion Guide for Enhanced Ion Transmission Kevin Giles and David Gordon Waters Corporation, Manchester, UK APPLICATION BENEFITS We describe a novel conjoined ion guide that operates at

More information

The Best Way to Get the Right Answers... is in a Flash

The Best Way to Get the Right Answers... is in a Flash FlashQuant Workstation The Best Way to Get the Right Answers... is in a Flash FlashQuant Workstation: Integrating MALDI Speed with Triple Quad Selectivity 5.03E+02 0.011 1.40E+03 2.680 5.26E+02 0.011 1.30E+03

More information

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS)

Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Technical Specifications for the procurement of Inductively Coupled Plasma Mass Spectrometer (ICP-MS) Preamble An Inductively Coupled Plasma Mass Spectrometer (Quadrupole ICP-MS) is proposed to be procured

More information

830 Vacuum Quality Monitor

830 Vacuum Quality Monitor Granville-Phillips Vacuum Instrumentation 830 Vacuum Quality Monitor Featuring ART MS Technology February 2011 1 What is ART MS? ART MS Anharmonic Resonant Trap Mass Spectrometry or Auto Resonant Ion Trap

More information

PRISMAPLUS. The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications.

PRISMAPLUS. The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications. PRISMAPLUS The precise solution for mass spectrometry. Modular design. Powerful software. Wide range of applications. PRISMAPLUS The precise solution for mass spectrometry. The combination of high sensi

More information

AccuTOF LC Training Course

AccuTOF LC Training Course 1 AccuTOF LC Training Course JEOL USA, Inc. 11 Dearborn Road Peabody, MA 01960 Area map Restaurants: Wendy s Bennigan s Bertucci s 2 AccuTOF LC Training Course Monday Basic principle and history of TOF

More information

The 5975C Series MSDs: Normalized Instrument Tuning. Technical Overview. Introduction

The 5975C Series MSDs: Normalized Instrument Tuning. Technical Overview. Introduction The 5975C Series MSDs: Normalized Instrument Tuning Technical Overview Jeffrey T. Kernan and Harry Prest Introduction The automated optimization of ion detection in a mass spectrometer, commonly referred

More information

Agilent GC-MS Maintenance:

Agilent GC-MS Maintenance: Restek GC Accessories Agilent GC-MS Maintenance: Restek s Quick Reference Guide Replacement parts for Agilent ion sources now available. Optimize performance by upgrading ion source components and electron

More information

Autoresonant Trap Mass Spectrometry

Autoresonant Trap Mass Spectrometry 8 th Harsh Environment Mass Spectrometry Wokshop Autoresonant Trap Mass Spectrometry (ART MS) Sept 21, 2011 Gerardo A. Brucker and G. Jeffery Rathbone Granville-Phillips Vacuum Instrumentation Brooks Automation,

More information

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Application Note Meeting the Korean Method ES 04607.1 for Naphthalene ( 나프탈렌 ) with Static and Dynamic Headspace GC/MS Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1 Introduction The Korean

More information

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications.

PrismaPlus. The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The New Mass Spectrometer with the Added Plus! Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The PrismaPlus innovation The optimum combination of high sensitivity,

More information

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems GT-73A Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems Introduction: Kevin Kuchta Extrel CMS 575 Epsilon Drive, Pittsburgh, PA 538 (Poster presented at the 50th ASMS

More information

Residual Gas Analyzers XT Series

Residual Gas Analyzers XT Series Residual Gas Analyzers XT Series Products from ExTorr Inc. - Pirani, Ion Gauge, Quadrupole - All Included The Extorr XT residual gas analyzer is a quadrupole mass spectrometer complete with a built-in

More information

TRITON Plus Thermal Ionization MS. Another step ahead. in TIMS. Earth and Planetary Sciences Nuclear Sciences

TRITON Plus Thermal Ionization MS. Another step ahead. in TIMS. Earth and Planetary Sciences Nuclear Sciences TRITON Plus Thermal Ionization MS Another step ahead in TIMS Earth and Planetary Sciences Nuclear Sciences Based on more than 35 years of experience in variable multicollector instrumentation, we have

More information

Residual Gas Analyzers

Residual Gas Analyzers Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu systems SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection

More information

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit.

PRISMAPRO. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. Modular design. Powerful software. Low detection limit. The latest generation of compact mass spectrometers. The combination of high sensi tivity, maximum

More information

Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~

Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~ F e a t u r e A r t i c l e Feature Article Development of a Small Residual Gas Analyzer Utilizing the Quadrupole Array Structure Micropole System ~ QL Series ~ Hirokazu Kitaura The Micropole System is

More information

A new gold standard for Dioxin analysis A combined approach ; automated efficient clean-up together with a new Triple Quadrupole GC-MS/MS

A new gold standard for Dioxin analysis A combined approach ; automated efficient clean-up together with a new Triple Quadrupole GC-MS/MS A new gold standard for Dioxin analysis A combined approach ; automated efficient clean-up together with a new Triple Quadrupole GC-MS/MS Haruhiko Miyagawa, GCMS Product Manager Analytical &Measuring Instruments

More information

Micro Analytical Instruments - A System Approach. Jörg Müller Institut für Mikrosystemtechnik

Micro Analytical Instruments - A System Approach. Jörg Müller Institut für Mikrosystemtechnik Micro Analytical Instruments - A System Approach Jörg Müller Institut für Mikrosystemtechnik Technische h Universität i Hamburg-Harburg H b Outline Motivation Political Political Issues Design Principles

More information

Electron Multipliers. Introduction to ETP Electron Multipliers Selection by Technique: LC-MS 242

Electron Multipliers. Introduction to ETP Electron Multipliers Selection by Technique: LC-MS 242 Introduction to ETP 240-241 Selection by Technique: GC-MS 242 LC-MS 242 ICP-MS 242 TOF-MS 243 Magnetic Sector 243 Selection by Instrument 243-244 ETP are individually tested to ensure the highest quality.

More information

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs

Residual Gas Analyzers RGA100/200/ amu, 200 amu and 300 amu RGAs Residual Gas Analyzers RGA100/200/300 100 amu, 200 amu and 300 amu RGAs SRS Residual Gas Analyzers 100, 200 and 300 amu systems Better than 1 amu resolution 6 decades of dynamic range 5 10 14 Torr detection

More information

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology QUANTOF High-resolution, accurate mass, quantitative time-of-flight MS technology Orthogonal-acceleration time-of-flight (oatof) mass spectrometers are invaluable tools for the detection and identification

More information

ICP-MS. plasma 3. Multi-Collector ICP-MS.

ICP-MS. plasma 3. Multi-Collector ICP-MS. ICP-MS plasma 3 Multi-Collector ICP-MS www.nu-ins.com plasma 3 is a third generation Multi Collector ICP Mass Spectrometer (MC-ICP-MS), designed to provide the best possible precision and accuracy for

More information

KNOW TRAINING MORE WITH. PerkinElmer Training Catalogue 2013 Relevant, interactive, rich in content.

KNOW TRAINING MORE WITH. PerkinElmer Training Catalogue 2013 Relevant, interactive, rich in content. PerkinElmer Training Catalogue 2013 Relevant, interactive, rich in content. KNOW MORE WITH TRAINING PERKINELMER MISSION For people. For the environment. For the shared goal of a healthier future. Improving

More information

Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC

Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC Paper 170-2 Integration and Optimization of Hardware and Software for a Differential Flow Modulated GCxGC Roger Firor, James McCurry, Chunxiao Wang and Michael Feeney Agilent Technologies Wilmington, DE

More information

Mass Spectrometry and the Modern Digitizer

Mass Spectrometry and the Modern Digitizer Mass Spectrometry and the Modern Digitizer The scientific field of Mass Spectrometry (MS) has been under constant research and development for over a hundred years, ever since scientists discovered that

More information

New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03. Technical Note.

New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03. Technical Note. New fraction collection features with the Agilent 220 micro plate sampler and micro plate sampling software rev. A.03 Technical Note Introduction The Agilent 220 micro plate sampler (MPS) is an essential

More information

Ultra High Definition LC/MS

Ultra High Definition LC/MS Ultra High Definition LC/MS Achieving the utmost information from today s complex analyses Dr. John Fjeldsted General Manager LC/MS Division Agilent Technology Santa Clara, CA What is Ultra High Definition?

More information

NEPTUNE Plus Multicollector ICPMS. Another step ahead. in MC-ICP-MS. Earth and Planetary Sciences Nuclear Sciences

NEPTUNE Plus Multicollector ICPMS. Another step ahead. in MC-ICP-MS. Earth and Planetary Sciences Nuclear Sciences NEPTNE Plus Multicollector ICPMS Another step ahead in MC-ICP-MS Earth and Planetary Sciences Nuclear Sciences Based on more than 35 years of experience in variable multicollector instrumentation, we have

More information

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate.

HIQUAD. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. New high-end mass spectrometer! Fast, flexible and easy to operate. A modular solution for mass spectrometry With the new HiQuad mass

More information

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis HT3 Application Note Introduction Volatile organic compounds, VOCs, present in liquid food products play a very

More information

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer

Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer Performance characteristics of a new wide range, fast settling electrometer design for a residual gas analysis mass spectrometer MKS Spectra Products, January 2010 Design considerations for RGA components

More information

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology

Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology Next Generation Space Atomic Clock Space Communications and Navigation (SCaN) Technology John D. Prestage- 1 Next Generation Space Atomic Clock!! Hg Ion Clock Technology was selected as NASA OCT TDM!!

More information

"What s inside your car?

What s inside your car? "What s inside your car? Car interior emissions testing using Thermal desorption GC/MS analysis Inge de Dobbeleer EU GCMS specialist ThermoFisher Lara Kelly Sales Manager Markes Thermal desorption The

More information

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free

Physical Properties Measurement System (PPMS): Detailed specifications: Basic unit cryogen- free Physical Properties Measurement System (PPMS): A Cryogen-free Physical Properties Measurement system that operates over a wider range of temperature and magnetic fields: fully automated/computer controlled

More information

Aerosol Chemical Speciation Monitor ACSM

Aerosol Chemical Speciation Monitor ACSM ACSM Topics System Design -Lower cost Data acquisition thru Ethernet line and OPC, laptop Igor interface. Builds off of Squirrel tools Design Philosophy -fill the matrix -file formats -runtime view and

More information

Ensure reliable and repeatable multi-component gas analysis.

Ensure reliable and repeatable multi-component gas analysis. Ensure reliable and repeatable multi-component gas analysis. Rosemount X-STREAM Enhanced Continuous Gas Analyzers Realize significant costs savings with flexible and accurate multi-component, multi-method

More information

Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry Applications

Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry Applications Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry Applications Bruce Laprade and Raymond Cochran Introduction Microchannel Plates (Figures 1) are parallel

More information

Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates

Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates Sub-mm Linear Ion Trap Mass Spectrometer Made Using Lithographically Patterned Ceramic Plates Ailin Li Brigham Young University, Provo, UT Coauthors: Qinghao Wu, Yuan Tian, Derek Andrews, Aaron Hawkins,

More information

Introduction of New Products

Introduction of New Products Field Emission Electron Microscope JEM-3100F For evaluation of materials in the fields of nanoscience and nanomaterials science, TEM is required to provide resolution and analytical capabilities that can

More information

The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications.

The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications. A P A S S I O N F O R P E R F E C T I O N PrismaPlus The Perfect Solution for Mass Spectrometry. Modular Design. Powerful Software. Wide Range of Applications. PrismaPlus The Perfect Solution for Mass

More information

CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO. Operating Instructions. Basement Spec Lab:

CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO. Operating Instructions. Basement Spec Lab: CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO Operating Instructions Basement Spec Lab: 00.097 crs Page of 2 This is a guide to using the MALDI Micro for those who have received training.

More information

Then the mass spectrometer should go to the field, in your hand, small as possible, light as possible, and operated with light battery.

Then the mass spectrometer should go to the field, in your hand, small as possible, light as possible, and operated with light battery. My name is Mo Yang from Korea Basic Science Institute. Everybody here knows that a mass spectrometer is the most powerful analytical tool in chemistry. However, the target samples you want to analyze are

More information

Examining Comprehensive Flow-Modulated Two-Dimensional Gas Chromatography

Examining Comprehensive Flow-Modulated Two-Dimensional Gas Chromatography Examining Comprehensive Flow-Modulated Two-Dimensional Gas Chromatography Roger L. Firor Senior Applications Chemist, Agilent Technologies roger_fi ror@agilent.com 1 Agilent Measurement Journal Gas chromatography

More information

Agilent 1260 Infinity Variable Wavelength Detector

Agilent 1260 Infinity Variable Wavelength Detector Agilent 1260 Infinity Variable Wavelength Detector Features, Technical Details, Specifications and Ordering Details Highest sensitivity for HPLC and RRLC The Agilent 1260 Infinity Variable Wavelength Detector

More information

Fragmentation of Ions in a Low Pressure Linear Ion Trap

Fragmentation of Ions in a Low Pressure Linear Ion Trap Fragmentation of Ions in a Low Pressure Linear Ion Trap Bruce A. Collings MDS SCIEX, Concord, Ontario, Canada The efficiency of in-trap fragmentation in a low-pressure linear ion trap (LIT), using dipolar

More information

Experiment 6: Franck Hertz Experiment v1.3

Experiment 6: Franck Hertz Experiment v1.3 Experiment 6: Franck Hertz Experiment v1.3 Background This series of experiments demonstrates the energy quantization of atoms. The concept was first implemented by James Franck and Gustaf Ludwig Hertz

More information

Measuring photometric accuracy using the double aperture method

Measuring photometric accuracy using the double aperture method Measuring photometric accuracy using the double aperture method Application Note Author Robert Francis Agilent Technologies, Inc. Mulgrave, Victoria 3170, Australia. Introduction Photometric accuracy is

More information

Charge-Sensing Particle Detector PN 2-CB-CDB-PCB

Charge-Sensing Particle Detector PN 2-CB-CDB-PCB Charge-Sensing Particle Detector PN 2-CB-CDB-PCB-001-011 Introduction The charge-sensing particle detector (CSPD, Figure 1) is a highly charge-sensitive device intended to detect molecular ions directly.

More information

Photograph: Norith Eckbo

Photograph: Norith Eckbo Photograph: Norith Eckbo Contaminants in Polar Regions PBDEs Particle deposition (high K OA ) HCHs High volatility: Single hoppers (high K AW ) Condensation DDT PCBs Evaporation Low volatility (low K AW

More information

Chem466 Lecture Notes. Spring, 2004

Chem466 Lecture Notes. Spring, 2004 Chem466 Lecture Notes Spring, 004 Overview of the course: Many of you will use instruments for chemical analyses in lab. settings. Some of you will go into careers (medicine, pharmacology, forensic science,

More information

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation

Spectroscopy in the UV and Visible: Instrumentation. Spectroscopy in the UV and Visible: Instrumentation Spectroscopy in the UV and Visible: Instrumentation Typical UV-VIS instrument 1 Source - Disperser Sample (Blank) Detector Readout Monitor the relative response of the sample signal to the blank Transmittance

More information

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring

HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring HPR-30 Vacuum Process Gas Analyser A differentially pumped RGA system for vacuum process monitoring HPR-30 vacuum process gas analyser To analyse processes with high dynamic range operating at pressures

More information

The development of the low-pressure linear ion

The development of the low-pressure linear ion Fragmentation of Ions in a Low Pressure Linear Ion Trap Bruce A. Collings MDS SCIEX, Concord, Ontario, Canada The efficiency of in-trap fragmentation in a low-pressure linear ion trap (LIT), using dipolar

More information

MIMS Workshop F. Hillion. MIMS Workshop

MIMS Workshop F. Hillion. MIMS Workshop MIMS Workshop 23 - F. Hillion MIMS Workshop 1/ Practical aspects of N5 Tuning Primary column : small probe, high current, influence of Z. Dynamic Transfer and scanning. Cy and P2/P3. LF4, Q and chromatic

More information

Zeiss Process Gas Analyzer (PGA) based on Ion Trap technology: Zeiss-PGA shows outstanding performances as in-line, real time gas analyzer

Zeiss Process Gas Analyzer (PGA) based on Ion Trap technology: Zeiss-PGA shows outstanding performances as in-line, real time gas analyzer Zeiss Process Gas Analyzer (PGA) based on Ion Trap technology: Zeiss-PGA shows outstanding performances as in-line, real time gas analyzer Dr.-Ing. M. Aliman Principal Scientist M. Aliman / ZEISS Agenda

More information

LC/MS Purification System TRILUTION LC v3.0 User s Guide

LC/MS Purification System TRILUTION LC v3.0 User s Guide LC/MS Purification System TRILUTION LC v3.0 User s Guide Gilson, Inc. PO Box 620027 Middleton, WI 53562-0027, USA Tel: 608-836-1551 or 800-445-7661 Fax: 608-831-4451 Gilson S.A.S. 19, avenue des Entrepreneurs

More information

Frequency Multiplier Development at e2v Technologies

Frequency Multiplier Development at e2v Technologies Frequency Multiplier Development at e2v Technologies Novak Farrington UK Millimetre-Wave User Group Meeting National Physical Laboratory 05-10-09 Outline Sources available Brief overview of doubler operation

More information

Non-Destructive Ion Trap Mass Analysis at High Pressure. Supporting information

Non-Destructive Ion Trap Mass Analysis at High Pressure. Supporting information Non-Destructive Ion Trap Mass Analysis at High Pressure Supporting information Wei Xu 1, Jeffrey Maas 2, Frank Boudreau 3, William J. Chappell 2 and Zheng Ouyang 1,2,3* 1. Weldon School of Biomedical Engineering,

More information

Ku-Band Receiver System for SHAO

Ku-Band Receiver System for SHAO Ku-Band Receiver System for SHAO Overview Brent Willoughby July 2014 Atacama Large Millimeter/submillimeter Array Expanded Very Large Array Robert C. Byrd Green Bank Telescope Very Long Baseline Array

More information

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE

Transpector 2. Gas Analysis System. NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE Transpector 2 Gas Analysis System NEW-GENERATION RGAs WITH SUPERIOR SENSITIVITY AND PERFORMANCE We ve made the best RGAs better. Inficon, the leaders in RGA technology, have upgraded the Transpector gas

More information

Status of the PRad Experiment (E )

Status of the PRad Experiment (E ) Status of the PRad Experiment (E12-11-106) NC A&T State University Outline Experimental apparatus, current status Installation plan Draft run plan Summary PRad Experimental Setup Main detectors and elements:

More information

The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers

The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers Presented ASMS 2007 New Instrumentation Concepts Session, Poster 043 Bruce

More information

Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES

Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Capillary Flow Technology: GCxGC Flow Modulator GET A SECOND DIMENSION OF INFORMATION ON COMPLEX MIXTURES Maximize information while collecting and analyzing GC data Comprehensive two-dimensional GC, or

More information

Status Report on Time and Frequency Activities at National Physical Laboratory India

Status Report on Time and Frequency Activities at National Physical Laboratory India Status Report on Time and Frequency Activities at National Physical Laboratory India (TCTF 2015) Ashish Agarwal *, S. Panja. P. Arora, P. Thorat, S. De, S. Yadav, P. Kandpal, M. P. Olaniya, S S Rajput,

More information

Quantum frequency standard Priority: Filing: Grant: Publication: Description

Quantum frequency standard Priority: Filing: Grant: Publication: Description C Quantum frequency standard Inventors: A.K.Dmitriev, M.G.Gurov, S.M.Kobtsev, A.V.Ivanenko. Priority: 2010-01-11 Filing: 2010-01-11 Grant: 2011-08-10 Publication: 2011-08-10 Description The present invention

More information

GenTechTM. Putting New Life Into Old Instruments Since 1996! Phone: Website: GenTechScientific.com

GenTechTM. Putting New Life Into Old Instruments Since 1996! Phone: Website: GenTechScientific.com GenTechTM Putting New Life Into Old Instruments Since 1996! Phone: 585.492.1068 Website: GenTechScientific.com Email: Sales@GenTechScientific.com Gas Chromatograph & GC/MS Systems, Accessories, Kits, Parts,

More information

NPD - Nitrogen Phosphorus Detector

NPD - Nitrogen Phosphorus Detector NPD - Nitrogen Phosphorus Detector NPD Overview - The NPD detector is highly selective to Nitrogen and Phosphorus containing compounds. A precisely controlled Hydrogen and Air mixture surrounds the NPD

More information

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design TECHNICAL NOTE 43333 Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design Keywords Optical design, Polychromator, Spectrometer Key Benefits The Thermo Scientific icap 7000

More information

New Control Electronics for Helmer Gauges

New Control Electronics for Helmer Gauges New Control Electronics for Helmer Gauges Nikolaos Chatzigeorgiou TE-VSC-ICM Technology Department ICM Automation FORUM, 24th May 2016 Agenda The Helmer gauge Control electronics Supervision application

More information

Finer Points of ICP-OES Setup and Operation

Finer Points of ICP-OES Setup and Operation Finer Points of ICP-OES Setup and Operation (Part 1) James Bartos Office of Indiana State Chemist Challenges with Fertilizers Broad conc ranges from low ppm to upper % level Want to test all nutrient elements

More information

Analytical Chemistry II

Analytical Chemistry II Analytical Chemistry II L3: Signal processing (selected slides) Semiconductor devices Apart from resistors and capacitors, electronic circuits often contain nonlinear devices: transistors and diodes. The

More information

Automated Double Aperture Accessory

Automated Double Aperture Accessory For the Cary 1, 3, 100, 300, 4, 5, 400, 500, 500i, 4000, 5000, 6000i, Deep UV Installation Category II Pollution Degree 2 Equipment Class I Table of Contents Introduction Theory Operation Installation

More information

Progress towards Actinic Patterned Mask Inspection. Oleg Khodykin

Progress towards Actinic Patterned Mask Inspection. Oleg Khodykin Progress towards Actinic Patterned Mask Inspection Oleg Khodykin Outline Status (technical) of EUV Actinic Reticle Inspection program Xe based LPP source as bright and reliable solution Requirements Choice

More information

instruments Analytical Instruments for Science

instruments Analytical Instruments for Science instruments Analytical Instruments for Science instruments Contents PAGE NO. Introduction 4 T60 UV-Vis Spectrophotometer 6 T70 UV-Vis Spectrophotometer 10 T80 UV-Vis Spectrophotometer 14 T90+ UV-Vis Spectrophotometer

More information

8.2 Common Forms of Noise

8.2 Common Forms of Noise 8.2 Common Forms of Noise Johnson or thermal noise shot or Poisson noise 1/f noise or drift interference noise impulse noise real noise 8.2 : 1/19 Johnson Noise Johnson noise characteristics produced by

More information

version 7.6 RF separator

version 7.6 RF separator version 7.6 RF separator www.nscl.msu.edu/lise dnr080.jinr.ru/lise East Lansing August-2006 Contents: 1. RF SEPARATOR...3 1.1. RF SEPARATION SYSTEM (RFSS) PROPOSAL AT NSCL... 3 1.2. CONSTRUCTION OF THE

More information

Advances in Antenna Measurement Instrumentation and Systems

Advances in Antenna Measurement Instrumentation and Systems Advances in Antenna Measurement Instrumentation and Systems Steven R. Nichols, Roger Dygert, David Wayne MI Technologies Suwanee, Georgia, USA Abstract Since the early days of antenna pattern recorders,

More information

Basic Components of Spectroscopic. Instrumentation

Basic Components of Spectroscopic. Instrumentation Basic Components of Spectroscopic Ahmad Aqel Ifseisi Assistant Professor of Analytical Chemistry College of Science, Department of Chemistry King Saud University P.O. Box 2455 Riyadh 11451 Saudi Arabia

More information

A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER

A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER GENERAL A NEW GENERATION PROGRAMMABLE PHASE/AMPLITUDE MEASUREMENT RECEIVER by Charles H. Currie Scientific-Atlanta, Inc. 3845 Pleasantdale Road Atlanta, Georgia 30340 A new generation programmable, phase-amplitude

More information

Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601. MTCS2601 silicon sensing die in SMD ceramic package

Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601. MTCS2601 silicon sensing die in SMD ceramic package Sensor Description Thermal Conductivity Sensor for Leak or Pressure Detection MTCS2601 MTCS2601 silicon sensing die in SMD ceramic package Thermal conductivity sensor for primary vacuum measurement Silicon

More information

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276

LOW COST SDI 2210, 2260 & 2266 HIGH PERFORMANCE SDI 2220 & 2276 LOW COST & HIGH PERFORMANCE 1-AXIS DC ACCELEROMETER MODULES Low Noise: 10 μg Hz Typical for ±2g Full Scale Versions -55 to +125 C Operating Temperature Range Flexible +8 to +32 VDC Power Excellent Long

More information

AMS Hardware / Upgrades / Development

AMS Hardware / Upgrades / Development AMS Hardware / Upgrades / Development Performance Operational Problems, failures and some general comments AMS Users Meeting Oct. 13, 22 Hardware Upgrades Planned for 21 Adjustable lens system 16 mm Quad

More information

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

PMT tests at UMD. Vlasios Vasileiou Version st May 2006 PMT tests at UMD Vlasios Vasileiou Version 1.0 1st May 2006 Abstract This memo describes the tests performed on three Milagro PMTs in UMD. Initially, pulse-height distributions of the PMT signals were

More information

Finishing first how automated systems improve the productivity and repeatability of wafer lapping and polishing

Finishing first how automated systems improve the productivity and repeatability of wafer lapping and polishing Finishing first how automated systems improve the productivity and repeatability of wafer lapping and polishing Author: Mark Kennedy www.logitech.uk.com Overview The lapping and polishing of wafers for

More information

Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA)

Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA) Click to edit Master title style Unique Scattering Measurements Using the Agilent Universal Measurement Accessory (UMA) mark.fisher@agilent.com Click to edit Master title style Rapid, Automated, Quality

More information