Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty.

Size: px
Start display at page:

Download "Page 4-6. STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 16A...690A 440V / 7.5kW...375kW 400V ratings in IEC AC3 duty."

Transcription

1 Page -2 Page - DIRECT-ON-LINE STARTERS Motor ratings up to 9A 0V in IEC AC duty General use up to 6A / motor rating up to 2A 600V per UL/CSA Versions with Start-Stop/Reset buttons or Reset button Versions with and without thermal relay Versions with motor protection circuit breaker. REVERSING CONTACTOR ASSEMBLIES For three-phase motor control 9...2A 0V /...2.kW 00V, in IEC AC duty and up to HP 600V per UL/CSA Versions with built-in or external mechanical interlock Complete with rigid connections PCB version 9A 0V / kw 00V in IEC AC duty; HP 00V per UL/CSA. Page - CHANGEOVER CONTACTOR ASSEMBLIES For 20A loads at 0 C in IEC AC duty For 20A general use per UL/CSA With built-in mechanical interlock. Page -6 STAR-DELTA STARTERS OPEN FRAME Suitable for three-phase motor control, 6A...690A 0V / 7.kW...7kW 00V ratings in IEC AC duty. Page -7 STAR-DELTA STARTERS IN NON-METALLIC ENCLOSURE Suitable for three-phase motor control, A 0V / 7.kW...0kW 00V ratings in IEC AC duty. Page -8 EMPTY NON-METALLIC ENCLOSURES Versions without pushbuttons, with Reset button only or Start-Stop/Reset buttons For starters, with pushbuttons and metal plate Suitable to contain BG mini-contactor or BF09A to BF0 contactors, up to 0A 0V rating in IEC AC duty; up to 2A at 600V for UL/CSA.

2 ELECTROMECHANICAL STARTERS AND ENCLOSURES Direct-on-line starters in non-metallic enclosure complete with or without thermal relay Versions with RESET or START/STOP pushbuttons Non-metallic enclosures for customer-assembled starters Reversing and changeover contactor assemblies Star-delta starters, open frame and in non-metallic enclosure versions. Direct-on-line starters - Full voltage across the line - Non reversing SEC. - PAGE Enclosed with thermal relay Enclosed without thermal relay... - Enclosed with motor protection circuit breaker... - Combinations Reversing contactor assemblies With BG series mini-contactors... - With BF series contactors... - Changeover contactor assemblies With BG series mini-contactors... - Star-delta starters Open frame Enclosed Non-metallic enclosure for starters Empty non-metallic enclosures Enclosures Accessories and spare parts Combinations MOTOR CONTROL AND PROTECTION

3 Direct-on-line starters - Full voltage across the line. Non reversing three phase Enclosed with thermal overload relay M0 P...2 M P...2 M2 P...2 M2 P08 2 M2 R08 2 M P...2 M0 R...2 M R...2 M2 R...2 Order code Relay IEC technical Qty Wt adj characteristics per range ( 0V) pkg Ie kw [A] [A] [kw] n [kg] Starters with Start and Stop/Reset pushbuttons ❷. M0 P009 2❶ M0 P009 2❶V M0 P009 2❶2V M0 P009 2❶ M0 P009 2❶ M0 P009 2❶ M0 P009 2❶ M0 P02 2❶ M P009 2❶A M P009 2❶A M P009 2❶A M P009 2❶A M P009 2❶A M P009 2❶A M P009 2❶B M P08 2❶B M2 P02 2❶B M2 P02 2❶B M2 P02 2❶B M2 P08 2❶B M P00 2❶B M P06 2❶B M P080 2❶B M P09 2❶B Starters with Reset pushbuttons ❷. M0 R009 2❶ M0 R009 2❶V M0 R009 2❶2V M0 R009 2❶ M0 R009 2❶ M0 R009 2❶ M0 R009 2❶ M0 R02 2❶ M R009 2❶A M R009 2❶A M R009 2❶A M R009 2❶A M R009 2❶A M R009 2❶A M R009 2❶B M R08 2❶B M2 R02 2❶B M2 R02 2❶B M2 R02 2❶B M2 R08 2❶B M R00 2❶B M R06 2❶B M R080 2❶B M R09 2❶B ❶ Complete order code with coil voltage digit (if 0/60Hz) or with voltage digit followed by 60 (if 60Hz). Standard voltages are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / / / 7 60 (V). Example: M0 R for direct-on-line starter in M0 type enclosure with Reset button, 9A/AC contactor with 2VAC 0/60Hz coil and 0.6-A thermal overload relay. M0 P for direct-on-line starter in M0 type enclosure with Start and Stop/Reset buttons, 9A /AC contactor with 2VAC 60Hz coil and 0.6-A thermal overload relay. ❷ Protection fuses are to be mounted externally by the user. Components Starter enclosure Contactor Thermal Auxiliary relay contact block M0 PA BG09 0A RF9 M0 PA BG09 0A RF9 V M0 PA BG09 0A RF9 2V M0 PA BG09 0A RF9 M0 PA BG09 0A RF9 M0 PA BG09 0A RF9 7 M0 PA BG09 0A RF9 0 M0 PA BG2 0A RF9 M PA BF09 0A RF8 000 M PA BF09 0A RF8 060 M PA BF09 0A RF8 020 M PA BF09 0A RF8 000 M PA BF09 0A RF8 060 M PA BF09 0A RF8 000 M PA BF09 0A RF8 00 M PA BF8 0A RF8 800 M2 PA BF2 0A RF8 200 M2 PA BF2 0A RF8 200 M2 PA BF2 00A RF8 200 G8 0 M2 PA BF8 00A RF8 800 G8 0 M PA BF0 00A RF G8 0 M PA BF6 00A RF G8 0 M PA BF80 00A RF G8 0 M PA BF9 00 RF9 9 G8 0 M0 RA BG09 0A RF9 M0 RA BG09 0A RF9 V M0 RA BG09 0A RF9 2V M0 RA BG09 0A RF9 M0 RA BG09 0A RF9 M0 RA BG09 0A RF9 7 M0 RA BG09 0A RF9 0 M0 RA BG2 0A RF9 M RA BF09 0A RF8 000 M RA BF09 0A RF8 060 M RA BF09 0A RF8 020 M RA BF09 0A RF8 000 M RA BF09 0A RF8 060 M RA BF09 0A RF8 000 M RA BF09 0A RF8 00 M RA BF8 0A RF8 800 M2 RA BF2 0A RF8 200 M2 RA BF2 0A RF8 200 M2 RA BF2 00A RF8 200 G8 0 M2 RA BF8 00A RF8 800 G8 0 M RA BF0 00A RF G8 0 M RA BF6 00A RF G8 0 M RA BF80 00A RF G8 0 M RA BF9 00 RF9 9 G8 0 Certifications and compliance Refer to page - for details. Special M... versions Refer to page - for details. UL/CSA HP ratings See page -2. M R Combinations pages -0 to pages -6 and 7 page -20

4 Direct-on-line starters - Full voltage across the line. Non reversing three phase Enclosed without thermal overload relay Order code Maximum operating Qty Wt current ( 0V) per pkg [A] n [kg] Starters with Start and Stop/Reset pushbuttons ❷. M0 P009 0❶ M0 P02 0❶ Components Starter enclosure Contactor Thermal Auxiliary standard standard relay to contact supplied supplied purchase standard separately supplied M0 PA BG09 0A RF9❸ M0 PA BG2 0A RF9❸ M0 P...0 M0 R...0 M P009 0❶ 0.90 M P08 0❶ M PA BF09 0A RF8❹ M PA BF8 0A RF8❹ M2 P02 0❶ M2 P02 0❶ 2.62 M2 PA BF2 0A RF8❹ M2 PA BF2 00A RF8❹ G8 0 M2 P08 0❶ M2 PA BF8 00A RF8❹ G8 0 M P...0 M R...0 M P00 0❶ 0.0 M P06 0❶ 6.0 M P080 0❶ 80.0 M P09 0❶ 9.0 Starters with Reset pushbutton ❷. M0 R009 0❶ M0 R02 0❶ M PA BF0 00A RF82❺ G8 0 M PA BF6 00A RF82❺ G8 0 M PA BF80 00A RF82❺ G8 0 M PA BF9 00 RF9 ❺ G8 0 M0 RA BG09 0A RF9❸ M0 RA BG2 0A RF9❸ M2 P...0 M2 R...0 M R009 0❶ M R08 0❶ M RA BF09 0A RF8❹ M RA BF8 0A RF8❹ M2 R02 0❶ M2 R02 0❶ 2.0 M2 RA BF2 0A RF8❹ M2 RA BF2 00A RF8❹ G8 0 M2 R08 0❶ M2 RA BF8 00A RF8❹ G8 0 M2 P08 0 M2 R08 0 M R00 0❶ M R06 0❶ M R080 0❶ M R09 0❶ ❶ Complete order code with coil voltage digit if 0/60Hz or with voltage digit followed by 60 if 60Hz. Standard voltages are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / / / 7 60 (V). Example: M0 R for direct-on-line starter in M0 type enclosure with Reset button, 9A /AC contactor with 2VAC 0/60Hz coil. M0 P for direct-on-line starter in M0 type enclosure with Start and Stop/Reset buttons, 9A /AC contactor with 2VAC 60Hz coil. ❷ Protection fuses are to be mounted externally by the user. M RA BF0 00A RF82❺ G8 0 M RA BF6 00A RF82❺ G8 0 M RA BF80 00A RF82❺ G8 0 M RA BF9 00 RF9 ❺ G8 0 ❸ For thermal overload relay selection, refer to pages -2 or -. ❹ For thermal overload relay selection, refer to pages -. ❺ For thermal overload relay selection, refer to pages - or -. Operational characteristics Cable entry: M0/M - 2 knockouts PG./M20 on enclosure top and bottom M2-2 knockouts PG./M20 or PG6/M2 on enclosure top and bottom M2-2 knockouts PG6/M2-PG29/M2 on enclosure top and bottom M - Smooth surfaces; can be drilled by customer Ambient conditions: Operating temperature: C Storage temperature: C Degree of protection: IP6 for all; type /X industrial control environment for M / M2 / M2... and M... UL versions. M P...0 Special M... versions In addition to standard-indicated versions, culus certified starters are available up to 2A motor control or 6A general use rating max. Add suffix UL to the order code, e.g. M P UL. UL/CSA HP ratings See page -2. M R...0 Certifications and compliance Certifications obtained: EAC for all; UL Listed for USA and Canada (culus File E9602) and CSA certified for Canada and USA (ccsaus File 97) as Magnetic Motor Controllers, enclosed type, for all M0-M-M2- M2P/R starters and MP/R0-6 UL types as indicated in Special M above. Compliant with standards: IEC/EN 6097-, IEC/EN , UL08, CSA C22.2 n. Combinations pages -0 to pages -6 and 7 page -20 -

5 Direct-on-line starters Full voltage across the line. Non reversing three phase Enclosed with motor protection circuit breaker M2 P Order code Relay IEC technical Qty Wt adj characteristics per range ( 0V) pkg Ie kw [A] [A] [kw] n [kg] M2 P009 ❶A M2 P009 ❶A M2 P009 ❶A M2 P009 ❶A M2 P009 ❶A M2 P009 ❶A M2 P009 ❶B ❶ Complete order code with coil voltage digit (if 0/60Hz) or with voltage digit followed by 60 (if 60Hz). Standard voltages are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / / / 7 60 (V). Example: M2 P A8 for direct-on-line starter in M2 type with reset and reset/emergency button, 9A/AC contactor with 00VAC 0/60Hz coil and motor protection circuit breaker...6.a. General characteristics The M2 P starters are composed of an IP6 plastic enclosure where the following devices are mounted: a motor protection circuit breaker type SMR... with the short circuit and overload protection function a contactor with start / stop function of the motor 2 push-buttons for the start and stop a mushroom push-button for the emergency stop a padlockable rotary actuator, that operates the circuit breaker, for the isolation. These starters are easily and quickly installable. They are especially suitable to operate the motor of smaller machines where there is no electrical panel. Inside the enclosure, other components can be added like timers, level relays, protection relays, etc. Operational characteristics M2-2 knockouts PG./M20 or PG6/M2 on enclosure top and bottom Ambient conditions: Operating temperature: C Storage temperature: C Degrre of protection: IEC IP6, type /X for UL version. Certifications and compliance Certifications obtained: EAC. Compliant with standards: IEC/EN 6097-, IEC/EN Combinations pages -0 to pages -6 page -20

6 Reversing and changeover contactor assemblies Reversing contactor assemblies BGR... BFA... BGT... BGTP... Changeover contactor assemblies BGC09... Order code IEC Max. IEC Built-in Qty Wt Ie (AC) power auxiliary per 0V AC contacts pkg C 00V at C [A] [kw] NO NC n [kg] AC COIL. Terminals: clamp screw. External interlock with power and auxiliary wiring. BGR09 0 A❶ 9 0 ❸ 0.9 BGR2 0 A❶ ❸ 0.9 BFA009 2❶ ❸ BFA02 2❶ ❸ BFA08 2❶ ❸ BFA02 2❶ ❸ Built-in interlock with power wiring only. BGT09 0 A❶ 9 ❸ BGT2 0 A❶ 2.7 ❸ Rear terminals: PCB solder pins. Built-in interlock only. BGTP09 0 A❶ 9 ❹ 0 ❸ 0.00 DC COIL. Terminals: clamp screw. External interlock with power and auxiliary wiring. BGR09 0 D❷ 9 0 ❸ 0.60 BGR2 0 D❷ ❸ 0.60 Built-in interlock with power wiring only. BGT09 0 D❷ 9 ❸ 0 0. BGT2 0 D❷ 2.7 ❸ 0 0. Rear terminals: PCB solder pins. Built-in interlock only. BGTP09 0 D❷ 9 ❹ 0 ❸ 0.60 Order code IEC Operating UL/CSA Qty Wt current (AC) General per Use pkg 0 C C 60 C [A] [A] [A] [A] n [kg] AC COIL. Terminals: clamp screw. Built-in interlock only. BGC09 T A❶ DC COIL. Terminals: clamp screw. Built-in interlock only. BGC09 T D❷ ❶ Complete order code with coil voltage digit or with voltage digit followed by 60 if 60Hz. Standard voltages are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / / / 7 60 (V). Example: BGR09 0 A02 for reversing contactor assembly with 2 mini-contactors BG09 having NC auxiliary contact each and 2VAC 0/60Hz coil. BGR09 0 A02 60 for reversing contactor assembly with 2 mini-contactors BG09 having NC auxiliary contact each and 2VAC 60Hz coil. ❷ Complete order code with coil voltage digit. Standard voltages are: -- DC 02 / 02 / 08 / 060 / 0 / 2 / 220V. Example: BGC09 T D02 is a changeover contactor assembly with 2 mini-contactors BG09 having main poles each and 2VDC coil. ❸ One auxiliary contact for each contactor. ❹ Maximum voltage is limited at 00V for UL. For certified type up to 600V, consult Customer Service; see contact details on front inside cover. General characteristics REVERSING CONTACTOR ASSEMBLIES Supplied complete, ready for quick mounting. The various versions are composed as follows: BGR... Screw termination, external mechanical BGT... interlock BGX0 00, power and auxiliary wiring. Screw termination, built-in mechanical interlock and power wiring only. BGTP... Rear PCB solder pin termination, built-in mechanical interlock only. No thermal overload relay can be directly mounted to BG... reversing contactor assemblies. BFA... Screw termination, mechanical interlock BFX0 02 and power wiring. The thermal overload relay RF8... can be directly mounted to BFA... reversing contactor assemblies; for selection, refer to section. CHANGEOVER CONTACTOR ASSEMBLIES Supplied complete, ready for quick mounting as follows: BGC09 T Four-pole contactors with built-in mechanical interlock. No power or auxiliary wiring included. Operational characteristics Type Maximum IEC operational power at C (AC) 20V 00V V 0V 00V 690V [kw] [kw] [kw] [kw] [kw] [kw] BGR BGT BGTP09❹ BGR BGT BFA BFA BFA BFA at 0 C (AC) BGC09 T Maximum UL/CSA horsepower rating Single phase Three phase 20V 20V 208V 20V 80V 600V [HP] [HP] [HP] [HP] [HP] [HP] BGR09 ½ ½ 2 BGT09 ½ ½ 2 BGTP09 ½ ½ 2 ❹ -❹ BGR2 ½ ½ 7½ 0 BGT2 ½ ½ 7½ 0 BFA009 ¾ 2 7½ BFA02 2 7½ 0 BFA08 0 BFA02 2 7½ 7½ NOTE: BGR09, BGT09, BGR2, BGT2 types are UL Listed for USA and Canada as Magnetic Motor Controller Reversing Contactors. All these are rated 20A general (purpose) use and suitable for use on a circuit capable of delivering more than ka symmetrical. Amps at 600V max when protected by fuses class K rated no more than 0A. BGTP09 type is UL Recognized for USA and Canada as Magnetic Motor Controller Component reversing contactors. Max HP rating up to 00VAC only; rated 20A general (purpose) use. BGC types are UL Listed for USA and Canada as Magnetic Motor Controller Changeover contactor. No coil change or replacement is possible for any BG types. Add-on blocks Refer to section 2, pages 2-6 and 2-8. Special add-on auxiliary contacts BGX or BGX 2 must be used on the left-side contactor of the BGT reversing assemblies. For the right-side contactor, normal BGX0... types of auxiliary contacts can be used instead. Refer to page 2-6 for details. Certifications and compliance Certifications obtained: UL Listed for USA and Canada (File E9602) for BGR09, BGT09, BGR2, BGT2, BFA... and BGC... (see NOTE above). UL Recognized, for USA and Canada (culus - File E9602 Component), for BGTP09; products having this type of marking are intended for use as components of complete workshop-assembled equipment. Compliant with standards IEC/EN 6097-, IEC/EN , UL08, CSA C22.2 n. Add-on blocks pages 2-6 and 2-7 pages -7 and 8 page -20 Technical characteristics pages 2-8 to

7 Star-delta starters Open frame Order code Three-phase Thermal Qty Wt BFA009...BFA02 motor control. overload per Max IEC relay operating pkg current ( 0V) [A] n [kg] Complete star-delta starters, open frame, for starting time up to 2s and a maximum of 0 operations/hour. BFA009 70❶❷ 6 No.700 BFA02 70❶❷ 22 No.700 BFA08 70❶❷ 28 No.700 BFA02 70❶❷ No.800 BFA026 70❶❷ No.800 BFA02 70❶❷ 0 No.900 BFA08 70❶❷ 60 No.900 BFA00 70❶❷ 8 No.200 BFA06 70❶❷ 0 No.200 BFA080 70❶❷ 0 No DYF9 E❸❶ Yes NYF ❸❶ 220 Yes NYF ❸❶ 260 Yes NYF80 ❸❶ 0 Yes NYF20 ❸❶ 80 Yes NYF0 ❸❶ 0 Yes NYF00 ❸❶ 690 Yes Operational characteristics IEC standard motor powers 20V 00V 0V 00V [kw] [kw] [kw] [kw] ❶ Complete order code with the coil voltage digit or the coil voltage digit followed by 60 if 60Hz. Standard voltage are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / (V). Example: BFA for BFA009 star-delta starter with 2VAC 0/60Hz power supply. BFA for BFA009 stardelta starter with 2VAC 60Hz power supply. ❷ The thermal overload relay is not included and must be purchased separately. Refer to the example given under Thermal relay adjustment range, for a correct choice and then to page - for the order code. ❸ The thermal overload relay is included. Replace with digit of thermal relay; see tables above, under Thermal relay adjustment range. ❹ To be mounted by the customer. ❺ Fuses for type co-ordination. For type 2 co-ordination, consult Customer Service; see contact details on inside front cover. ❻ TM ST with auxiliary supply VAC. TM ST A0 with auxiliary supply VAC. NOTE: For higher powers and voltages, or suitable for heavy-duty starting (centrifugal fans, mills, crushers) that is with starting time exceeding 2s, consult Customer Service; see contact details on inside front cover. Thermal relay adjustment range Choose the thermal relay adjustment range considering a value equal to 8% of rated motor current (Ie). Example: Ie=00A; 8% Ie=8A. The suitable relay range is 6-6A. During the setup, the relay is to be regulated at 8A. For DYF... type Digit defining Relay IEC am DYF thermal adj fuses starters relay range range A ❹❺ A For NYF... type Digit defining Relay IEC am NYF thermal adj fuses starters relay range range A ❹❺ A Components Starter Contactors Thermal Time relay Auxiliary contacts fitted Rigid overload on contactor: connections Line Delta Star relay Line Delta Star BFA BF09 0A BF09 0A BF09 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX BFA02 70 BF2 0A BF2 0A BF09 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX BFA08 70 BF8 0A BF8 0A BF2 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX BFA02 70 BF2 0A BF2 0A BF8 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX BFA BF26 00A BF26 00A BF8 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX0 BFX2 2 BFA02 70 BF2 00A BF2 00A BF2 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX0 BFX2 2 BFA08 70 BF8 00A BF8 00A BF2 0A ❷ (RF8) TM ST❻ BFX0 20 BFX0 BFX0 BFX2 2 BFA00 70 BF0 00A BF0 00A BF2 00A ❷ (RF82) TM ST❻ BFX0 20 BFX0 BFX0 BFA06 70 BF6 00A BF6 00A BF2 00A ❷ (RF82) TM ST❻ BFX0 20 BFX0 BFX0 BFA BF80 00A BF80 00A BF0 00A ❷ (RF82) TM ST❻ BFX0 20 BFX0 BFX0 DYF9 E BF9 00 BF9 00 BF0 00A RF9 TM ST❻ BFX0 20 BFX0 BFX0 NYF B 00 B 00 BF6 00 RF200 TM ST❻ G0 G BFX0 NYF B 00 B 00 BF80 00 RF200 TM ST❻ G0 G BFX0 NYF80 B80 00 B80 00 B 00 RF200 TM ST❻ G0 G G NYF20 B20 00 B20 00 B 00 RF20 TM ST❻ G0 G G NYF0 B0 00 B0 00 B80 00 RF20 TM ST❻ G0 G G NYF00 B00 00 B00 00 B20 00 RF20 TM ST❻ G0 G G Reference stardards Compliant with stardards: IEC/EN 6097-, IEC/EN page -8 pages -2 to 2

8 Star-delta starters. Non-metallic enclosure for starters Enclosed starters M P M PA70 ❶ Complete order code with the coil voltage digit or the coil voltage digit followed by 60 if 60Hz. Standard voltage are as follows: -- AC 0/60Hz 02 / 08 / 0 / 20 / 00V -- AC 60Hz / / / / (V). Example: MP for MP009 stardelta starter with 2VAC 0/60Hz power supply. MP for MP009 star-delta starter with 2VAC 60Hz power supply. ❷ The thermal overload relay is not included and must be purchased separately. Choose the thermal relay adjustment range considering a value equal to 8% of rated motor current (Ie). Example: Ie=0A; 8% Ie =.8A. The suitable relay range is -6.A, set at.8a, so the order code to select is RF8060). Refer to page - for the order codes available. ❸ Suitable for BFA...70 starters. ❹ TM ST with auxiliary supply VAC; TM ST A0 with auxiliary supply VAC. NOTE: For higher powers and voltage ratings or suitable for heavy-duty starting (centrifugal fans, mills, crushers) that is with starting time exceeding 2s, consult Customer Service; see contact details on inside front cover. Order Three-phase motor Qty Wt control. per Max IEC operating pkg current ( 0V) [A] n [kg] Star-delta starters in enclosure with Start and Stop/Reset buttons. Starting time up to 2s and a maximum of 0 operations/hour. M P009 70❶❷ 6.0 M P02 70❶❷ 22.0 M P08 70❶❷ 28.0 M P02 70❶❷.60 M P026 70❶❷.60 M P02 70❶❷ M P08 70❶❷ With switch disconnector, rotary door-coupling handle GAX6 and Start and Stop/Reset buttons. M P009 7❶❷ M P02 7❶❷ M P08 7❶❷ M P02 7❶❷.800 M P026 7❶❷.800 M P02 7❶❷ 0.00 M P08 7❶❷ Enclosure for star-delta starter, complete with Start and Stop/Reset buttons, metal plate fixed with piece of mm DIN (IEC/EN 607) rail. M PA70 ❸ 2.20 Operational characteristics IEC standard motor powers Maximum available space inside MP...70/7 with star-delta starters BFA V 00V 0V 00V [kw] [kw] [kw] [kw] Cable entry: Smooth surface; can be drilled by customer Ambient conditions: Operating temperature: C Storage temperature: C Degree of protection: IEC IP6 for MP ; UL Type, 2, /X for M UL versions. Special M... versions In addition to standard-indicated versions, culus certified starters are available up to 2A motor control rating max. This is also valid for the enclosure with general use rating of 6A. Add suffix UL to the order code, e.g. M PA70UL. Certifications and compliance Certifications obtained: UL Listed, for USA and Canada (File E9602), as Magnetic Motor Controllers - Enclosed (starters) and - Enclosures for M...PUL types. Compliant with standards: IEC/EN 6097-, IEC/EN , UL08, CSA C22.2 n for starters; UL 08A for MP A70UL Components Type Enclosure Contactors T/o Time Auxiliary contacts fitted Rigid Switch relay relay on contactor: connec- disconnector Line Delta Star ❷ Line Delta Star tions ❺ MP009 70/7 M PA70 BF09 0A BF09 0A BF09 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX GA06 A MP02 70/7 M PA70 BF2 0A BF2 0A BF09 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX GA02 A MP08 70/7 M PA70 BF8 0A BF8 0A BF2 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX GA02 A MP02 70/7 M PA70 BF2 0A BF2 0A BF8 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX GA00 A MP026 70/7 M PA70 BF26 00A BF26 00A BF8 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX0 BFX2 2 GA06 SA MP02 70/7 M PA70 BF2 00A BF2 00A BF2 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX0 BFX2 2 GA06 SA MP08 70/7 M PA70 BF8 00A BF8 00A BF2 0A (RF8) TM ST❹ BFX0 20 BFX0 BFX0 BFX2 2 GA06 SA ❺ For MP...7 types Combinations page - page -9 page -2-7

9 Empty non-metallic enclosures Accessories and spare parts Empty enclosures M...PA M...RA M...N Accessories and spare parts MX 20P MX 2P Order code Contactor type Thermal Degree Qty Wt ❶ relay of per ❷ protect. pkg Enclosures with Start-Stop/Reset pushbuttons. n [kg] M0PA BG06, BG09, RF9 IP BG2 MPA BF09A, BF2A, RF8 IP6 0. BF8A M2PA BF2A, BF26A RF8 IP6 0.7 BF2A M2PA❸ BF8A RF8 IP MPA❹ BF0A, BF0A, RF82 IP6.900 BF6A, BF80A, RF82 BF9, BF0 RF9 Enclosures with Reset pushbutton. M0RA BG06, BG09, RF9 IP6 0. BG2 MRA BF09A, BF2A, RF8 IP BF8A M2RA BF2A, BF26A RF8 IP BF2A M2RA❸ BF8A RF8 IP MRA❹ BF0A, BF0A, RF82 IP6.80 BF6A, BF80A, RF82 BF9, BF0 RF9 Enclosures without external pushbuttons. M0N BG06, BG09, RFA9 IP6 0.0 BG2 MN BF09A, BF2A, RF8 IP BF8A M2N❸ BF2A, BF26A RF8 IP BF2A M2N❸❺ BG.../ ❷ IP BF09A...BF2A M2N❸ BF8A RF8 IP MN BF0A, BF0A, RF82 IP6.800 BF6A, BF80A, RF82 BF9, BF0 RF9 ❶ To be purchased separately; refer to page 2- for contactor choice. ❷ To be purchased separately. Refer to pages -2 to 8 for thermal overload relay choice. For use of the overload relay in the M2N, consult Customer Service; see contact details on inside front cover. ❸ MX metal mounting plate included. ❹ MX 0 metal mounting plate included. ❺ To install eventual pushbuttons, selectors and/or other control accessories, use the series and mount the relay contact elements on the cover using the LPX AU20 mounting adapter. See section 7. Order code Description Qty Wt per pkg n [kg] MX 0 Threaded plug for unused holes, grey RAL70 MX 0P Stop/Reset button extension 0.00 rod for M0 enclosure MX P Stop/Reset button extension 0.00 rod for M enclosure MX 2P Stop/Reset button extension 0.00 rod for M2 enclosure MX 20P Mounting base for LPX C contact on M0 enclosure MX 2P Mounting base for LPX C contact on M, M2, M2 enclosure MX 0 Metal mounting plate for MN 0.00 MX Metal mounting plate for M2N 0.00 and M2 enclosures Enclosure Maximum operating current type ( 0V) A M M... 8 M M2N 8 M M... 0 General characteristics Enclosures are supplied with the following accessories: Accessory Type of enclosure M0 PA M PA M2 PA M2 PA M0 RA M RA M2 RA M2 RA Description Type Contact MX 20P holder MX 2P Buttons: LPC B76 - Start/Reset LPC B20 - Start LPC B Contact for LPX C0 Start button Stop/Reset MX 0P button MX P extension MX 2P Unused hole MX 0 threaded plug M PA enclosure: 2 Start and Stop/Reset pushbuttons, 2 G28 auxiliary terminals and MX0 mounting plate M RA enclosure: Reset pushbutton, 2 G28 auxiliary terminals and MX0 mounting plate MN enclosure: Supplied without accessories to be purchased separately including MX 0 mounting plate. Enclosures can house the following devices: M0 = BG with/without RF9 M = BF09A-BF2A-BF8A with/without RF8 M2 = BF2A-BF26A-BF2A, assemblies BFA 2 with/without RF8 M2N = BF2A-BF26A-BF2A, assemblies BGR/BGT/BGC and BFA 2 without overload M2 = BF26 BF8A, assemblies BGR/BGT/BGC and BFA 2 with/without overload M = BF0 BF0 and all assemblies with/without overload. Operational characteristics: Cable entry: M0/M//M2-2 knockouts PG./M20 on enclosure top and bottom M2N/M2-2 knockouts PG6/M2-PG29/M2 on enclosure top and bottom M - Smooth surfaces; can be drilled by customer Ambient conditions: Operating temperature: C Storage temperature: C Degree of protection: IEC IP6 for all; UL Type, 2, /X for M0/M/M2/M2N/M2 types and M UL versions. Special M versions In addition to standard-indicated versions, culus certified starters and enclosures are available up to 2A - motor control and 6A general use rating max (MX0 plate, earth/ground and neutral terminal plates are always included in this case). Add suffix UL to the order code of enclosures e.g. MN UL. Certifications and compliance Certifications obtained: EAC for all; for MNUL type, UL Listed for USA and Canada (culus File E0000) as Industrial control panels; for M0/M/M2PA/RA/N and other M UL types, UL Listed for USA and Canada (culus File E9602) under magnetic motor controllers as Polymeric enclosures - and CSA certified for Canada and USA (ccsaus File 97) as Non-metallic enclosures. UL/CSA pending for M2N and M2 types. Compliant with standards: IEC/EN 6097-, IEC/EN , UL 08, CSA CS22.2 n ; UL 08A and CSA -8 Combinations pages -0 to pages -6 and 7 page -20

10 Empty non-metallic enclosures M...PA EMPTY ENCLOSURES M0PA MPA M2PA M2PA MPA MPA M...RA EMPTY ENCLOSURES M0RA MRA M2RA M2RA MRA MRA M...N EMPTY ENCLOSURES M0N MN M2N M2N M2N MN Metal mounting plate MX (standard supplied) Metal mounting plate MX (standard supplied) Metal mounting plate MX 0 (to purchase separately) pages -6 and 7 page -20-9

11 Direct-on-line starters - Full voltage across the line. Non reversing three phase M...P... STARTERS, ENCLOSED M0 P M0 P M0 P M0 P M P M P M P M P M2 P M2 P M2 P M2 P M...R... STARTERS, ENCLOSED M0 R M0 R M0 R M0 R M R M R M R M R M2 R M2 R M2 R M2 R M2... STARTERS, ENCLOSED M2... STARTERS, ENCLOSED M2 P M2 P M2 R M2 R M2 P009 M... STARTERS, ENCLOSED M P to M P M P to M P M R to M R M R to M R pages -6 and 7 page -20

12 Direct-on-line starters - Full voltage across the line. Accessories and spare parts Maximum combinations for M0... and M... starters in enclosure For the fitting of add-on blocks and electronic relays in the starters, consult our Customer Service; see contact details on inside front cover. The enclosure cover can be equipped with various types of actuators and pilot lights, per following details: ) Upper position The cover must be drilled in this position, with a 22.mm hole, by the user and LPL..., LPM... and LPC ZS... pilot light can be fitted. To fit the LPL... (not type 8 LP2T IL P) pilot light head, the mounting base, type MX 20P for M0 enclosure or type MX 2P for M enclosure, must also be purchased. The LED element is snapped onto this mounting base. No adapter or base is needed for LPL..., LPM... and LPC ZS... 2) Middle position 2 Based on the enclosure type, in this position, the user finds either the Start button or threaded plug. Various actuators can be fitted in this position, such as flush or extended buttons, selectors or pilot lights, as illustrated below. To fit the actuators, the mounting base, type MX 20 for M0 enclosure, or type MX 2P for M enclosure, must also be purchased. The contact or LED elements are snapped onto this mounting base. No adapter or base is needed for LPL..., LPM... and LPC ZS... ) Lower position The STOP/RESET button is mounted in this position, except for the enclosure without buttons. This button activates the thermal overload relay via a mechanical actuator. In eventual applications without thermal overload relay, this button can be removed and the hole closed up by the threaded plug MX 0. 7.mm x Time relay TM... Protection relay PMV0 A0 Level control relay LVM2 20 Priority change relay LVMP 0 (one only relay on the left of the contactor) LPX C0... LPX C... LPX CS... LPX LP... LPX LE... LPX LPS... LPX C0... LPX C... LPX CS... MX 20P (M0) MX 2P (M) LPL... LPM... LPC ZS... MX 0 LPC BL... LPC QL... 2 LPC B... LPC Q... LPC S... MO... BG... M... BF09A BF2A BF8A LPC S... LPC SL... LPC B7... LPC BL7... LPC B7... RF9 RF8 pages -6 page -20 -

13 Direct-on-line starters - Full voltage across the line. Accessories and spare parts Maximum combinations for M2... starters in enclosure For the fitting of add-on blocks and electronic relays in the starters, consult our Customer Service; see contact details on inside front cover. The enclosure covers can be equipped with various types of actuators and pilot lights, per following details: ) Upper position The cover must be drilled in this position with a 22.mm hole by the user; LPL..., LPM... or LPC ZS... pilot light can be fitted. To fit the LPL... pilot light, the mounting base type MX 2P must also be purchased. The LED element is snapped onto this mounting base. No adapter or base is needed for LPL..., LPM... and LPC ZS... 2) Middle position 2 Based on the enclosure type, in this position, the user finds either the Start button or threaded plug. Various actuators can be fitted in this position, such as flush or extended buttons, selectors or pilot lights, as illustrated in the side figure. To fit the actuators (not required for 8 LP2T IL P pilot light), the mounting base type MX 2P must also be purchased. The contact or LED elements are snapped onto this mounting base. No adapter or base is needed for LPL..., LPM... and LPC ZS... ) Lower position The STOP/RESET button is mounted in this position, except for the enclosure without buttons. This button activates the thermal overload relay via a mechanical actuator. In eventual applications without thermal overload relay, this button can be removed and the hole closed up by the threaded plug MX 0. Various actuators can be fitted in this position, such as flush or extended buttons, selectors or pilot lights, as illustrated in the drawing below. To fit the actuators (not required for 8 LP2T IL P pilot light), the mounting base type MX 2P must also be purchased. The contact or LED elements are snapped onto this mounting base. No adapter or base is needed for LPL..., LPM... and LPC ZS... ) Upper position The cover must be drilled in this position with a 22.mm hole by the user whenever an external handle is needed for a switch disconnector fitted in the enclosure. Time relay TM... Protection relay PMV0 A0 Level control relay LVM2 20 Priority change relay LVMP 0 (two relays or one only on left and one on right side of the contactor) 7.mm mm 2 x or max x LPX C0... LPX C... LPX CS... PMV20/0/0/0//70... protection relay PMF20 A... protection relay PM0/0... protection relay LMV20... level control relay (one relay only on right side of the contactor) LPX LP... LPX LE... LPX LPS... LPX C0... LPX C... LPX CS... GAX6 GAX6 B GAX68 GAX68 B LPL... LPM LPC ZS... MX 2P MX 0 LPC BL... LPC QL... MX 2P 2 LPC B... LPC Q... M2... M2... M2... LPC S... BF2A BF26A BF2A n 2 BF09A n 2 BF2A n 2 BF8A n 2 BF2A BF09A BF2A BF8A BF2A BF26A BF2A LPC S... LPC SL... LPC B7... LPC BL7... ON I GAX7 090 OFF 0 BFX0 02 LPC B7... RF8 RF8 RF8 GA06 A GA02 A GA02 A LPC B pages -7 page -20

14 Maximum combinations for starters in M2N enclosure In addition to a direct-on-line, full voltage across the line, starter or reversing contactor assembly, various other electromechanical devices can be fitted. The cover of the M2N enclosure can be used across the entire surface to mount pushbuttons, measuring instruments, switch disconnectors GA06A GA00A and GA06SA type. No contact blocks or other additional accessories can be mounted on the contactor face of AC BF series; they can only be fitted on the contactor side since the cover is shallow. Eventually pushbuttons, selector switches and/or other control accessories of the series can be used and contact or LED elements can be mounted directly inside on the cover with the LPX AU20 mounting adapter; refer to section 7. The wall fixing holes and the cover closing captive screws are positioned outwards with respect to the sealing gasket. This guarantees the protection degree of the enclosure against infiltrations liquid (IEC IPX / UL Type X). The base has ribbing which facilitates the fixing of DIN rails, metal mounting plates and electronic printed boards. Grid references, marked by letters and numbers, are engraved on the interior surface of the cover. This grid allows to quickly identify the exact drilling points where pushbuttons, handles or pilot lights will be mounted. A safety sealing system keeps the cover and base together to avoid inopportune opening and tampering. Available space for fitting other electrical or electronic devices 0 82,6 6 M2N BG06 BG09 BG2 without overload M2N M2N M2N BF09A...BF2A without overload BGR... - BGT... - BGC... without overload n 2 BF09A n 2 BF2A n 2 BF8A n 2 BF2A All without overload BFA...2 without overload BF09A BF2A BF8A BF2A with GA06A...GA00A and GA06SA BFX0 02 ON I OFF 0 BFX0 0 pages -7 page -20 -

15 Maximum combinations for starters in M2 enclosure In addition to a direct-on-line, full voltage across the line, starter or reversing contactor assembly, various other electromechanical devices can be fitted. The cover of the M2 enclosure can be used across the entire surface to mount pushbuttons, measuring instruments, switch disconnectors GA06A GA00A and GA06SA type. Possible contact blocks or other additional accessories can be mounted on the contactor face of AC or DC BF series or on the contactor side since the cover is deep. Eventually pushbuttons, selector switches and/or other control accessories of the series can be used and contact or LED elements can be mounted directly inside on the cover with the LPX AU20 mounting adapter; refer to section 7. MX internal metal mounting plate is standard-supplied. The wall fixing holes and the cover closing captive screws are positioned outwards with respect to the sealing gasket. This guarantees the protection degree of the enclosure against liquid infiltrations (IEC IPX / UL Type X). The base has ribbing which facilitates the fixing of DIN rails, metal mounting plates and electronic printed boards. Grid references, marked by letters and numbers, are engraved on the interior surface of the cover. This grid allows to quickly identify the exact drilling points where pushbuttons, handles or pilot lights will be mounted. A safety sealing system keeps the cover and base together to avoid inopportune opening and tampering. Available space for fitting other electrical or electronic devices 0 6 7, 6 8 M M2... M2... M2... BF8 with or without overload BF26 - BF2 with or without overload BGR... - BGT... - BGC with or without overload RF9 n 2 BF26 - n 2 BF2 - n 2 BF8 with or without overload RF8 BFA...2 with or without overload RF8 BF09 BF2 BF8 BF26 BF2 BF8 with GA06A...GA00A and GA06SA BFX0 02 ON I OFF 0 RF8... RF8... RF8... BF09A...BF8A with BFX0 0 - pages -7 page -20

16 Direct-on-line starters Maximum combinations for starters in M enclosure In addition to a direct-on-line, full voltage across the line, starter or reversing contactor assembly, star-delta starters can be installed as illustrated at the lower right as well as various other electromechanical devices. The cover of the M enclosure can be used across the entire surface to mount pushbuttons, measuring instruments or switch disconnectors GA06A GA2A, etc. MX 0 internal metal mounting plate is standard supplied with MP and MR types; not included with the MN, it can be purchased separately. With the specifically designed hinges, the cover remains attached to the base, fully open, while the wiring work is being carried out. By applying slight pressure on the hinges, the cover can be released from the base. The cover closing captive screws and the wall fixing holes are positioned outwards with respect to the sealing gasket. This guarantees the protection degree of the enclosure against liquids infiltrations (IEC IPX / UL Type X). M... M P M P A safety sealing system keeps the cover and base together to avoid inopportune opening and tampering. Grid references, marked by letters and numbers, are engraved on the interior surface of the cover. This grid allows to quickly identify the exact drilling points where pushbuttons, handle or pilot lights will be mounted. A properly predrilled metal mounting plate (MX 0 standard supplied except for MN) permits to quickly and precisely fix equipment in place. The base has ribbing which facilitates the fixing of DIN rails, metal mounting plates and electronic printed boards. Available space for fitting other electrical or electronic devices M... M... M... n BF0 n BF0 n BF6 n BF80 n BF9 n BF0 n 2 BF0 n 2 BF0 n 2 BF6 n 2 BF80 n 2 BF9 n 2 BF0 n BF0 n BF0 n BF6 n BF9 n BF80 n BF0 + n GA... RF82 RF9 RF82 RF9 RF82 RF9 pages -7 page -20 -

17 [mm (in)] DIRECT-ON-LINE STARTERS - EMPTY ENCLOSURES M0 88 (.6 ) (.7 ) Ø. (0.8 ) 0. (. ). (.2 ) 9. (.70 ) M 88 (.6 ) (.7 ) Ø. (0.8 ). (6.2 ) 8. (.8 ). (.29 ) 8 (7.2 ) 7 (6.89 ) 202 (7.9 ) 9 (7.60 ) 9 (.9 ) 9. (0.76 ) 9 (.9 ) PG. / M20 knockouts on top and bottom 9. (0.76 ) PG. / M20 knockouts on top and bottom M2 M2 P009 0 (. ) (2.6 ) Ø. (0.8 ) 62. (6.9 ) 69. (6.70 ) 8. (.8 ) 0 (. ) (2.6 ) Ø. (0.8 ) 89. (7.6 ) 62. (6.9 ) 69. (6.70 ) 8. (.8 ) 2 (9.2 ) 22 (8.86 ) 60 (2.6 ) 22.8 (0.90 ) 2 (9.2 ) 22 (8.86 ) 60 (2.6 ) 22.8 (0.90 ) Ø0 (.8 ) PG. / M20 PG6/M2 knockouts on top and bottom PG. / M20 PG6/M2 knockouts on top and bottom -6

18 [mm (in)] M2N 7 (6.89 ) 98. (.88 ) M2 7 (6.89 ) 6 (6.0 ) 8, (6.2 ) 8, (.8 ) 20 (8.27 ) ) 28 (.0 ) 2 (2.0 ) Drilling for surface fixing. (6.0 ) Ø. (0.8 ) 28 (.0 ) 2 (2.0 ) Drilling for surface fixing. (6.0 ) Ø. (0.8 ) PG6 / M2 PG29 / M2 knockouts on top and bottom M (0. ) 220 (8.66 ) 87 (7.6 ) 77 (6.97 ) 70 (6.69 ) Drilling for surface fixing 78 (7.0 ) Ø 6.2 (0.2 ) 280 (.02 ) REVERSING CONTACTOR ASSEMBLIES BGR (.6 ).. (0.7 ) (0.7 ) Ø (0.6 ) 6 (0.2 ) BGT (.6 ).. (0.7 ) (0.7 ) Ø (0.6 ) ) 8. (0. ) 8. (0. ) BGTP (0.8 ) 88 (.6 ). (0.7 ). (0.7 ) 8 (2.28 ) (2.09 ) 0 (.97 ) Ø.❶ (0.0 ) 8 (2.28 ) 0 (.97 ) 8 (2.28 ) 0 (.97 ).9 (.7 ) 6 (2.20 ) 9.7 (0.8 ) 8. (0. ) 8. (0. ) BFA (0. ) 90 (. ).9 (.7 ) Ø.2 (0.6 ) 6 (2.20 ) 90 (. ) 8 (.27 ) 7 (2.79 ) 28 (9.7 ) 8, (.8 ) PG6 / M2 PG29 / M2 knockouts on top and bottom 8 (7.2 ) 8 (7.2 ) 9.7 (0.8 ) 8. (0. ) 8. (0. ) 8. (0. ) 6 (2.20 ).6 (0.22 ) ❶ Recommended PCB drillings.7-2mm ( ). (.8 ) -7

19 [mm (in)] CHANGEOVER CONTACTOR ASSEMBLIES BGC09 T (.6 ).. (0.7 ) (0.7 ) Ø (0.6 ).9 (.7 ) 6 (2.20 ) STAR-DELTA STARTERS OPEN FRAME BFA (0.9 ) 97. (7.77 ) 2. (6.00 ) 90 (. ) A B NYF... A C STARTER TYPE A B C NYF 0 (.8 ) 870 (.2 ) 9 (7.68 ) NYF 0 (.8 ) 870 (.2 ) 9 (7.68 ) NYF80 0 (.8 ) 870 (.2 ) 9 (7.68 ) NYF20 0 (7.2 ) 000 (9.7 ) 2 (9.2 ) NYF0 0 (7.2 ) 000 (9.7 ) 2 (9.2 ) NYF00 0 (7.2 ) 000 (9.7 ) 2 (9.2 ) B (0. ) STARTER TYPE A B BFA (. ) 09. (. ) BFA (. ) 09. (. ) BFA (. ) 09. (. ) BFA (. ) 09. (. ) BFA (. ) 9 (.68 ) BFA02 70 (. ) 9 (.68 ) BFA08 70 (. ) 9 (.68 ) BFA (6.8 ) 2 (.9 ) BFA (6.8 ) 2 (.9 ) BFA (7.20 ) 2 (.9 ) DYF (9.8 ) (0.9 ) (0.9 ) 6. (0.6 ) (. ) 9. (.9 ) (. ) 8 (6.22 ) 8 (2.28 ) 0 (.97 ) 9.7 (0.8 ) 8. (0. ) 8. (0. ) 8. (0. ) -8

20 [mm (in)] STAR-DELTA STARTERS IN ENCLOSURE - EMPTY ENCLOSURE FOR STAR-DELTA STARTERS MP M PA (.02 ) 87 (7.96 ) 77 (6.97 ) 70 (6.69 ) 220 (8.66 ) (0. ) Drilling for surface fixing Ø 6.2 (0.2 ) 28 (9.7 ) 20 (8.07 ) 6 (.7 ) 8 (7.28 ) 78 (7.0 ) 2 (9.6 ) MP (.02 ) 9 (7.60 ) 70 (6.69 ) (0. ) Drilling for surface fixing Ø 6.2 (0.2 ) 28 (9.7 ) 78 (7.0 ) 220 (8.66 ) 280 (.02 ) 70 (6.69 ) 92.9 (7.9 ) -9

21 DIRECT-ON-LINE STARTERS IN ENCLOSURE M...P Diagram - Incorporated button control for -phase motors LINE M...R Diagram 2 - External button control for -phase motors LINE M2 P Diagram - Incorporated button control and rotary actuator for -phase motors LINE Diagram - Power connection for -phase motors LINE 6 6 L L2 L A L L2 L () A L L2 L () L L2 L 2 6 T T2 T () 2 6 T T2 T I () 2 6 T T2 T O I R A T T2 T L L2 L 2 6 T T2 T T T2 T 2 6 T T2 T E 2 6 T T2 T O LOAD LOAD 2 LOAD I = Start; O = Stop/Reset R = Reset; I = Start; O = Stop I 2 6 T T2 T DIAGRAM 2: Connect the eventual two-wire control (e.g. automatism) between terminal of the contactor and terminal 96 of the thermal overload relay. IMPORTANT -- Remove jumpers and 6 and connect the auxiliary line to terminals A and for a control circuit with a voltage value different than the supply. -- Remove jumper and connect the neutral to terminal A for a control circuit between phase and neutral. -- SINGLE-PHASE SUPPLY The main circuit must be configured according to Diagram in the case of a single-phase line or motor. -- FUSES A set of three fuses must be connected upstream of the starter in the event no appropriate protection is included in the system. LOAD I = Start; O = Stop; E = Emergency Stop REVERSING CONTACTOR ASSEMBLY BGR... BGT... L L2 A L 2 A L L2 L 2 A L L2 L L L2 L A KM KM T T2 T 2 6 T T2 T T T2 T 2 6 T T2 T BFA...2 BGTP09... A L L2 L 2 A L L2 L 2 L L2 A 2 L L L2 L 2 A KM KM 2 6 T T2 T T T2 T T T2 T 2 6 T T2 T 22-20

22 CHANGEOVER CONTACTOR ASSEMBLY BGC09... L L2 A L L 7 L L2 L L 7 A KM T T2 T T STAR-DELTA STARTERS, OPEN FRAME AND ENCLOSED BFA MP T 6 8 T2 T T LINE...V -...Hz L L2 L KM KM FR 2 6 U2 V2 W2 M ~ U V W U2 V2 W2 M ~ U V W BFA BFA02 70 MP MP02 70 BF BFA08 70 MP MP S 22 S2 2 S 22 S KT (TM ST) 8 22 KM 96 2 FR KT A A (TM ST) KM KM KM 6 A A KM L KT (TM ST) 8 62 KM 96 6 FR KT A A (TM ST) KM KM KM 6 A A KM L -2

23 STAR-DELTA STARTERS, OPEN FRAME BFA00...BFA080 - DYF9 LINE...V -...Hz L L2 L KM KM FR 2 6 U2 V2 W2 M ~ U V W U2 V2 W2 M ~ U V W 2 S 22 S KT (TM ST) 8 62 KM KM KM 9 FR KT A (TM ST) 9 A KM A KM A L -22

24 STAR-DELTA STARTERS, OPEN FRAME NYF... KM 2 6 KM FR L L2 L LINE...V -...Hz U2 V2 W2 M ~ U V W U2 V2 W2 M ~ U V W S 22 S2 9 FR 96 7 KT (TM ST) 8 62 KM 6 KT A A (TM ST) KM KM 6 A KM KM A -2

25 Electromechanical starters and enclosures Direct-on-line starters Full voltage across the line. Non reversing CONFIGURATIONS FOR USA AND CANADA. Order code T/O MAX UL/CSA HP RATINGS INDICATED ON STARTER for magnetic motor starters RELAY (based on t/o relay adj range) in non-metallic enclosure ADJ with 2 push buttons RANGE Single phase Three phase [A] 20V 20V 200V 20V 80V 600V M0P009❶❷ ½ ½ M0P009❶❷V ¾ ¾ M0P009❶❷2V ½ M0P009❶❷ ¼ ¾ ½ ½ 2 M0P009❶❷ - - ½ M0P009❶❷ ¾ ½ 2 M0P009❶❷0 6-0 ½ ½ 2 M0P02❶❷❸ 9 - ½ ½ 7½ 0 MP009❶❷A ½ MP009❶❷A ½ ¾ MP009❶❷A ½ ½ ½ MP009❶❷A ¾ ¾ 2 MP009❶❷A8-6. ¼ ½ ½ MP009❶❷A ½ ½ 2 7½ MP009❶❷B0❸ 9 - ¾ 2 7½ MP02❶❷B0❸ 9-2 7½ 0 MP08❶❷B❸ M2P02❶❷B2 7-2 ½ 7½ M2P02❶❷B ½ 7½ M2P026❶❷B2 7-2 ½ 7½ 20 M2P026❶❷B ½ 7½ 20 M2P026❶❷B❸ ½ 7½ 20 M2P02❶❷B❸ 2-2 7½ M2P08❶❷B 2-8 7½ MP00❶❷B6UL❸❹ MP06❶❷B7UL❸❺ MP080❶❷B8❻ ❻ 0❻ 60❻ 7❻ MP09❶❷B9❻ ❻ 0❻ 60❻ 7❻ NOTE: The HP / FLA values vary from one motor to another; if possible, always verify the HP and FLA (or rated current) on the motor nameplate. Enclosure UL Type, 2, and X industrial control environment for M, M2, M2 and M UL versions; designation of control units can be: N without push buttons R with reset button only P per table, with start-stop push buttons S with start selector and stop push button. Consult Customer Service for any other combination required (e.g. with other type of contactors, contactor assemblies or definitepurpose version, different overload version or range, additional pilot lights, extra electrical or electronic elements); see contact details on inside front cover. Refer to ❶ below for specified standard configurations. ❶ Complete the order code by indicating: 0 if required without thermal overload relay 2 if required with three-phase overload relay if required with single-phase overload relay if required with automatic reset of overload relay for M0 types 7 if required with disconnect switch for M2 and M types 2 if required with reversing contactor combination for M2 and M types. ❷ Complete the order code by indicating coil voltage required: 0260 for 2V 60Hz 0860 for 8V 60Hz / 2V 0Hz 2060 for 20V 60Hz / 0V 0Hz for 220V 60Hz / 200V 0/60Hz 2060 for 20V 60Hz / 220V 0Hz 6060 for 60V 60Hz / 00V 0Hz 760 for 7V 60Hz. ❸ Maximum HP ratings per UL and CSA can be different when definite-purpose contactors are considered. Consult with Customer Service for further information; see contact details on inside front cover. ❹ Short circuit protective device This enclosed starter is suitable for use on a circuit capable of delivering not more than,000rms symmetrical amperes, 600V max, when protected with Class RK type, Fuse size 200A. ❺ Maximum UL ratings is 2A for motor control and 6A for general use. Short circuit protective device This enclosed starter is suitable for use on a circuit capable of delivering not more than 0,000rms symmetrical amperes, 600V max, when protected with Class RK type, Fuse size 22A. ❻ No CSA or UL certification. Indicated values correspond to UL/CSA magnetic contactor ratings and for indication and reference purposes only. Certifications obtained: CSA certified for Canada and USA (ccsaus - File 97) as Magnetic Motor Controllers at max 600VAC, max HP per single phase, max 60HP three phase, max 2A with general purpose enclosure. UL Listed for USA and Canada (culus - File E9602) as Magnetic Motor Controllers Enclosed. Markings: Line (voltage and frequency value) Amps (overload adjustment range) Max HP (horsepower value) Control (coil and frequency value) Caution: Bonding between conduits must be provided. -2

26 Typical full-load current values of single and three phase electric motors THREE-PHASE POWER RATINGS Rated motor current 200V 20V V 80-V 00V 0-80V 00V 0-600V 690V [HP] [kw] [A] [A] [A] [A] {A] [A] [A] [A] [A] / / / / SINGLE-PHASE POWER RATINGS Rated motor current [HP] [A] at 20V [A] at 20V /0. /8.8.9 / / / / / / / The information in the chart has been obtained from the IEC/EN standards. The kw ratings are preferred rated values according to IEC (primary series) at 0/60Hz while Horsepower and corresponding current values are according to UL 08 Industrial Control Standard at 60Hz. The full load current values listed are for motors running at standard speeds with normal torque characteristics. Motors which are non-standard, such as low speed, high torque or other special applications may have higher full load currents. Caution: For accurate and reliable motor protection, motor nameplate current should be used to obtain actual motor full load amps for all motors. The information given is for indication and reference purposes only. -2

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations Bulletin LP NEMA AC Permanent Magnet-Latching Lighting Contactors Product Overview/Product Selection/Wiring Diagram A, -Pole Open Type without Enclosure Bulletin LP Top wiring permanent magnet latching

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

XT IEC Power Control Miniature Controls

XT IEC Power Control Miniature Controls Product Family Overview May 07 Contents Description Page Selection................ Product Selection.......... Non-reversing Mini Contactors......... Reversing Mini Contactors............. Star-Delta (Wye-Delta)

More information

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg.

AC-3 AC-1 230V 400/415V 500V 690V 115V 230V 200V 230V 460V 575V N.O. N.C. Qty. Cat. No. Screw Terminals. Spring Clamp Terminals. 40 C Pkg. Bulletin -K, -K IEC Miniature Contactors Overview/Product Selection Product Selection -Pole AC- and DC-Operated Contactors Bulletin -K/-K IEC Miniature Contactors Compact size Same dimensions for AC and

More information

DISCONNECT SWITCHES. UL Listed CSA Certified

DISCONNECT SWITCHES. UL Listed CSA Certified POWER & ACTUATION ENCLOSED DISCONNECT SWITCHES When you need an at-motor non-fused disconnect switch with superior performance, look to c3controls. Our Series E2 Enclosed Disconnects feature 3- and 4-Pole

More information

Components for safety applications

Components for safety applications Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages

More information

Type: DILEM 10(220V50HZ,240V60HZ) Article No.:

Type: DILEM 10(220V50HZ,240V60HZ) Article No.: Type: DILEM 10(220V50HZ,240V60HZ) Article No.: 051785 Ordering information Actuating voltage Description Connection technique 380 V 400 V I e A 8.8 Max. rating for three phase motors, 50 AC 3 220 V 230

More information

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 8 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 10 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 12 Mini Contactors

More information

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC)

Auxiliary Contact (10 600V) Auxiliary Contact (10 5V DC) Bulletin C,, C Accessories Accessories Auxiliary Contacts Contactors are supplied with one normally open and one normally closed auxiliary contact (A rating) as standard. Additional auxiliary contacts,

More information

Type: DILEM 10 G(24VDC) Article No.:

Type: DILEM 10 G(24VDC) Article No.: Type: DILEM 10 G(24VDC) Article No.: 010213 Ordering information Description Connection technique Rated operational current AC 3 380 V 400 V I e A 9 Max. rating for three phase motors, 50 60 Hz AC 3 220

More information

Page 13-2 Page Page 13-7

Page 13-2 Page Page 13-7 Page -2 Page -6 MINIATURE CIRCUIT BREAKERS UP TO 63A 1P, 1P+N, 2P, 3P and 4P versions IEC rated current In: 1-63A IEC short-circuit capacity Icn: 10kA (6kA for 1P+N) Trip characteristic curve: Type B,

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC DATASHEET - ETR4-51-A Timing relay, star-delta, 50 ms, 1W, 3-60s, 24-240VAC/DC Part no. ETR4-51-A Catalog No. 031884 Eaton Catalog No. XTTR6A60S51B EL-Nummer 0004133308 (Norway) Delivery program Product

More information

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories Mini Contactor Relays 4-pole J7KN-R ) Main contactor C & DC operated 4-, 6- and 8-pole versions in different configurations Mirror contacts Screw fixing and snap fitting (35 mm DIN rail) Rated current

More information

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7

TeSys circuit-breakers Thermal-magnetic motor circuit-breakers types GV2, GV3 and GV7 Presentation Thermal-magnetic motor circuit-breakers types GV, GV and GV7 GV-ME, GV-P, GV-ME and GV7-R motor circuit-breakers are -pole thermal-magnetic circuit-breakers specifically designed for the control

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for product selection; not all combinations

More information

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE PAGE 262400-1 SECTION 262400 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Excerpt from Master Catalogue Circuit Breakers Specifically For You Hydraulic-magnetic technology ensures reduced nuisance tripping with temperature variance Always holds 00% rated current

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol

More information

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection DATASHEET - ETR4-70-A Delivery program Timing relay, 2W, 0.05s-100h, multi-function, 24-240VAC/DC, potentiometer connection Part no. ETR4-70-A Catalog No. 031888 Eaton Catalog No. XTTR6A100H70B EL-Nummer

More information

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Return To MAIN INDEX Magnetic Contactors, Overview / Contactors DIL...M Contactors AC Operated AC Operated, Reversing DC Operated AC/DC Operated, DC Hp ratings / /6 /8 / Starters DIL Universal Contactors

More information

FEATURES OPTIONAL FEATURES

FEATURES OPTIONAL FEATURES -00--0 B Series The Assured Automation B Series electric valve actuators offer a rugged design for quarter turn industrial applications. Designed for use on quarter turn (0 ) ball valves, butterfly valves,

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

For Immediate Delivery call KMParts.com at (866)

For Immediate Delivery call KMParts.com at (866) Moeller Wiring Manual / Page Overview - ON-OFF Switches, main switches, maintenance switches - Changeover switches, reversing switches - (Reversing) star-delta switches - Multi-speed switches - Interlock

More information

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker

T e c h n i c a l C a t a l o g u e MCCB. Moulded Case Circuit Breaker T e c h n i c a l C a t a l o g u e MCCB Moulded Case Circuit Breaker contents general overview... 2 feature - company profile and certifications... 6 MCCB - NF series circuit breaker, double repulsion

More information

Solid-State Switching Devices

Solid-State Switching Devices SIRIUS Solid-State Switching Devices Contents Pages Introduction.................................. 8/2 Solid-state switching devices General data.................................. 8/3 Solid-state switching

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA, RA Contactor Assemblies RA Contactor Assemblies for Wye-Delta Starting RA complete units,... kw Siemens AG 0 Overview These RA contactor assemblies for wye-delta starting are designed for standard

More information

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2. Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILER-22-G(24VDC) Catalog No. 010042 Eaton Catalog No. XTRM10A22TD EL-Nummer 4130354 (Norway) Product range DILER Mini-contactors Application

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton Edition 10/2016 HMI Components 41 Series Characteristics The rectangular design of the Series 41 (18 x 24 mm) makes it especially suited: Raised design PCB (with adaptor) Functions The Series 41 incorporates

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series

Item Number No. Poles NO/NC V DC 50/60 Hz. Aux Contactor NO/NC Resistive/ Inductive Amps Price. AF Series ABB Contactors Fits 35mm DIN rail Touch Safe Design Compact Design Captive Terminal Screws Built in surge protection (AF series only) Magnetic coil (AE series only) Electronically controlled coil (AE series

More information

Complete units: Selector switches ø 22mm

Complete units: Selector switches ø 22mm Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions

More information

FM series position switches

FM series position switches FM series position switches Selection diagram 0 08 0 A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass

More information

SIRIUS/SIKOSTART Soft Starters For Standard Applications

SIRIUS/SIKOSTART Soft Starters For Standard Applications Overview SIRIUS RW0/1 Various versions of the RW0/1 SIRUS soft starters are available: Standard version for fixed frequency three-phase motors, sizes S00, S0, S2 and S Version for fixed-speed three-phase

More information

CI-tronic Soft start motor controller

CI-tronic Soft start motor controller Data sheet CI-tronic Soft start motor controller MCI 3, MCI 15, MCI, MCI 30 I-O, MCI 40-3D I-O and MCI 50-3 I-O The MCI soft starters are designed for soft starting and stopping of 3 phase AC motors, thus

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Motor Protection Circuit Breaker Series 8146/5-V27

Motor Protection Circuit Breaker Series 8146/5-V27 www.stahl.de > For protection of Ex e and Ex d motors > Protects electric lines and plant equipment > Thermal overcurrent release, adjustable, phase failure sensitive > Electromagnetic quick release >

More information

Power Supplies 3. SDN-C Compact DIN Rail Series

Power Supplies 3. SDN-C Compact DIN Rail Series SDN-C Compact DIN Rail Series The SDN-C DIN rail power supplies are the next generation of the popular SDN series. These models combine high efficiency and compact size with new visual diagnostic LEDs

More information

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module DATASHEET - DILA-22(24VDC) Delivery program Contactor relay, 2N/O+2N/C, DC current Part no. DILA-22(24VDC) Catalog No. 276414 Eaton Catalog No. XTRE10B22TD EL-Nummer 4130211 (Norway) Product range DILA

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

Local control stations for Zone 1 and Zone 21. Features. Description

Local control stations for Zone 1 and Zone 21. Features. Description Local control stations for Zone and Zone Local control stations for Zone and Zone Features The right size/material enclosure Optimum functionality thanks to the great variety of components Customised planning

More information

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide

Bulletin 100S-C/104S-C Safety Contactors. Bulletin 700S-CF Safety Control Relays. Table of Contents. Selection Guide Bulletin S-C/S-C Safety Contactors Bulletin 7S-CF Safety Control Relays Selection Guide Table of Contents Description Page Bulletin S-C/S-C Safety Contactors Product Selection.................................

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg

Contactors & Relays. Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators. Pg Contactors & Relays Contactors & Relays Manual Motor Starters Miniature Circuit Breakers Earth Leakage Isolators Pg 223 230 231 232 232 Contactors & Relays Contactor - GMC Series 3 Pole (240V) AC 1 Rati

More information

Solid-State Soft Starters

Solid-State Soft Starters Selection and ordering data Rated operational voltage U e V Soft starters for three-phase asynchronous motors 3RW30 25-1B14 3RW30 35-1B14 t ambient temperature 40 C Size Order No. Price Weight Pack. Rated

More information

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink

Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink Solid State Relays 1- and 2 Pole SOLITRON With Integrated Heatsink AC Solid State Contactor, 1- and 2 poles Zero switching for heating and motor applications Instant-on switching Rated operational current

More information

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button

More information

Switching Devices Contactors and Contactor Assemblies for Switching Motors

Switching Devices Contactors and Contactor Assemblies for Switching Motors Switching Devices Contactors and Contactor Assemblies for Switching Motors groups 41B, 41H / Introduction Power contactors for switching motors /5 General data /11 SIRIUS RT10 contactors, -pole,... 50

More information

PKZ 2 Manual Motor Protectors Technical Data

PKZ 2 Manual Motor Protectors Technical Data 08/066 PKZ 2 Manual Motor Protectors General Standards UL 508, CSA C 22.2 No. 14, IEC/EN 60 947, VDE 0660 GL, LR, DNV, PRS, BV, RINA, RS, EZU, MEEI Climatic proofing Damp heat, constant, to IEC 60 068-2-3

More information

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87

Motor Control V12-T13-2 V12-T13-72 V12-T13-76 V12-T13-87 Motor Control Motor Control............................. Adjustable Frequency AC Drives............................. Synchronous............................................ Starters (Medium Voltage)..................................

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

Open Type Without Enclosure

Open Type Without Enclosure Bulletin L NEMA AC Electrically Held Lighting Contactors Product Selection Top Wiring for Non-Motor and Lighting Loads Tungsten Lamp Loads (Max. V Line, V Load) Maximum Continuous Ampere Ratings [A] General

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA DATASHEET - DILA-22(230V50HZ,240V60HZ) Delivery program Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(230V50HZ,240V60HZ) Catalog No. 276399 Eaton Catalog No. XTRE10B22F EL-Nummer 0004130208 (Norway)

More information

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays

Miniature Contactors & Starters. Series CA8 family of Contactors, Starters, and Overload & Industrial Relays Miniature & Starters Series family of, Starters, and Overload & Industrial Relays Miniature, Starters, Overload Relays & Industrial Controls List Prices shown in this selection guide are for use in the

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton Edition /204 HMI Components 8 Series Characteristics The compact 8 mm Series 8 is especially suited for: Flush design Raised design PCB (with adaptor) Functions The Series 8 incorporates the following

More information

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4

Block Contactors. Contents. Panorama 3-pole Contactors... 2/2 4-pole Contactors... 2/4 /0 Block Contactors Contents Panorama -pole Contactors... / 4-pole Contactors... /4 -pole Contactors: Description and Ordering Details A 9... A 0 Contactors (a.c. Operated)... /6 A 4... AF 60 Contactors

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green

More information

KRPA, KRP, KA, KR series

KRPA, KRP, KA, KR series Catalog 1084 Issued -0 KRPA, KRP, KA, KR series to 10 Amp General Purpose Relay File E944, E, E818 (KR Hermetic) File LR14 KRPA KRP KA Users should thoroughly review the technical data before selecting

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Actuators Series 8602/3

Actuators Series 8602/3 > Large selection of actuators Pushbuttons Mushroom pushbuttons Rotary actuators Key-operated switches Mushroom stay-put buttons with key lock Mushroom stay-put buttons Twin pushbuttons Illuminated pushbuttons

More information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information

Type: DILM80(110V50HZ,120V60HZ) Article No.: Sales text Contactor,37kW/400V,AC operated. Ordering information Type: DILM80(110V50HZ,120V60HZ) Article No.: 239399 Sales text Contactor,37kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards

IGS IGS-M-EL-22(1) Contactors APPROVED. Iranian Gas Standards APPROVED IGS Iranian Gas Standards Contactors. Fax:(9821)-8131-5679 --. /012 34-52673892 :;395- 8? /@A7 B;CD /E FGH 34-52673892I2

More information

NEMA Contactor and Starter Specifications

NEMA Contactor and Starter Specifications Technical Data NEMA Contactor and Starter Specifications Bulletins 00, 0, 0, 0, 06, 06X, 07, 07X, 09,,, E/F/G, E/F/G Topic Page Specifications Electrical Ratings Mechanical Ratings, Construction, Environmental

More information

ECM3 EARTH CONTINUITY RELAY

ECM3 EARTH CONTINUITY RELAY TECHNICAL DATASHEET ECM3 EARTH CONTINUITY RELAY Electrical Protection for Hard Rock Mines Application The ECM3 has been designed to provide earth continuity protection for cables containing pilot cores.

More information

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU

Mini contactors B 6 and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU /0 Mini contactors B and B 7 Mini contactor relays K.. Compact reversing contactors VB.. Thermal overload relay T 7 DU Contents Mini Contactors B, BC, B 7, BC 7 Ordering Details... /2 Compact Reversing

More information

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads)

Siemens AG Allows easy and consistent configuration with one series of overload relays (for small to large loads) Overview Features Benefits 3RU11 3RB20/3RB21 3RB22/3RB23 Sizes Are coordinated with the dimensions, connections S00...S3 S00... S12 S00... S12 and technical characteristics of the other devices in the

More information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information

Type: DILM95(230V50HZ,240V60HZ) Article No.: Sales text Contactor,45kW/400V,AC operated. Ordering information Type: DILM95(230V50HZ,240V60HZ) Article No.: 239480 Sales text Contactor,45kW/400V,AC operated Ordering information Connection technique Description Description Rated operational current AC 3 380 V 400

More information

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection

IPS INTELLIGENT PUMP STARTER. Integrated Tru-power electronic motor and pump protection IPS INTELLIGENT PUMP STARTER With TM Smartstart Ø & Ø, 0/60 Hz, 20~600 VAC, /~00HP Integrated electronic pump protection overload Power metering and data logging options Motor Protection Key dealer yr.

More information

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240

120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Industrial Environment AC-DC Converters >100 Watt W Series 120/240 Watt AC-DC Front End with PFC W Series Convert Select 120 Convert Select 240 Rugged 35 mm DIN-rail snap-fit design 3000 V AC input to

More information

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays .6 Control Relays and Timers Product Overview Catalog Number Selection D9, D96 and D99 Series Description D9 = Hockey puck D96 = Compact D99 = DIN rail Contents D 9 2 5 A M D 2 Output Voltage 1 = 2 60

More information

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs Function have all the same advantages as the 3RW30/31 soft starters. At the same they come with additional functions and a two-phase control method (Polarity Balancing) that is unique in the rating range

More information

Modular equipment. Presentation, standards. Standard contactors TeSys GC

Modular equipment. Presentation, standards. Standard contactors TeSys GC Presentation, standards Standard contactors TeSys GC Presentation TeSys GC contactors are designed for use in modular panels and enclosures. These contactors feature: b Easy installation v quick clip-on

More information

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance

Table of Contents. Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings. Technical Assistance Power Distribution Blocks & Terminal Blocks with High Short-Circuit Current Ratings Table of Contents Page Selection Table.... 2 Power Distribution Blocks PDBFS Series....................................3-8

More information

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only) 1-,, 3-, 4- Toggle Switches (Bul. 800T only) 800T T2 H2 E E X X a b c d e f g Right Left Right Left Blank C T1 T2 T3 T4 a Finger-Safe Guards Description No guards Guards on terminals b Operator Type Description

More information

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches PART 1 GENERAL 1.01 Scope Furnish and install automatic transfer switches (ATS) with number of poles, amperage, voltage, and withstand

More information

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947

J7M-AM/-BM. Motor--protective circuit--breaker system. J7M -BM System IEC 947, EN IEC 947, EN 60947 Motor--protective circuit--breaker system J7M -AM System Rated operational current 25 A. Switching capacity up to 10 A, 100 ka/415 V. Switching capacity 16 A, 20 A, 25 A, 16 ka/415 V. Fixed short--circuit

More information

190S A N D 2 C A16 C TE

190S A N D 2 C A16 C TE Bulletin / Eco and Compact Combination Starters Catalog Number Explanation Cat. No. Explanation Examples given in this section are for reference purposes. This basic explanation should not be used for

More information

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e

3/4/2015. Basic relay construction. Shading coil in AC relays. Timothy L. Skvarenina and William E. DeWitt Electrical Power and Controls, 2e FIGURE 12-1 Basic relay construction. FIGURE 12-2 Shading coil in AC relays. 1 FIGURE 12-3 Contactor coil and shaded pole stators. FIGURE 12-4 Magnetic motor starter. 2 FIGURE 12-5 Thermal overload devices.

More information

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65 Installation & Operation Manual RSDA SERIES ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65 Washdown and Watertight for Indoor and Outdoor Use MULTI-FUNCTION KEYPAD WITH 4-DIGIT LED DISPLAY

More information

3RH1 contactor relays, 4- and 8-pole

3RH1 contactor relays, 4- and 8-pole Siemens AG 2010 RH, TH Contactor Relays RH1 contactor relays, 4- and 8-pole Overview AC and DC operation IEC 60947, EN 60947. The RH1 contactor relays are suitable for use in any climate. They are finger-safe

More information

Bulletin 700-RTC Solid-State Timing Relay

Bulletin 700-RTC Solid-State Timing Relay Bulletin 700-RTC Solid-State Timing Relay Bulletin 700 RTC Solid State Timing Relay Timing functions 8 ON-delay 8 OFF-delay Timing ranges Seconds: 0.05 2, 0.2 8, 0.4 30, 2 120 Minutes: 0.015 1, 0.06 4,

More information

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35 Altech Corporation Since 1984, Altech Corporation has grown to become a leading supplier of automation and industrial control components. Headquartered in Flemington, NJ, Altech has an experienced staff

More information

Electronic Circuit Breaker with reset input ESS20-1..

Electronic Circuit Breaker with reset input ESS20-1.. Electronic Circuit Breaker with reset input ESS0-.. Description The special device ESS0-.. is a further extension of the product line electronic circuit breakers. Type ESS0-.. has a width of only. mm and

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors.

The CWC0 compact contactors are offered as a complete solution for switching and controlling motors. Compact Contactors The CWC compact contactors are offered as a complete solution for switching and controlling motors. Main Features Contactors with screw s for C-3 operation up to Contactors with spring

More information

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders. Contents Description. CHDB Series Power Distribution Blocks. Power Distribution

8.3. Terminal Blocks, Fuse Blocks and Fuse Holders.  Contents Description. CHDB Series Power Distribution Blocks. Power Distribution Terminal Blocks, Fuse Blocks and Fuse Holders.3 CHDB Series Blocks, Enclosed and Open CHDB Series Blocks Product Description Features and Benefits Eaton s CHDB Series of Blocks was designed for high short

More information

Description Basic devices with positive operation contacts

Description Basic devices with positive operation contacts Contactorrelay,3N/O+1N/C,DCcurrent Partno. DILA-31(24VDC) Articleno. 276379 CatalogNo. XTRE10B31TD Deliveryprogramme Product range DILA relays Application Contactor relays Description Basic devices with

More information

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV

SIEMENS ENERGY & AUTOMATION INC DISTRIBUTION PRODUCTS DIV Certificate Number 20081124 E29197A Page 1 of 8 Report Reference E29197, 1974 September 17 Issue Date 2008 November 24 Issued to: This is to certify that representative samples of SIEMENS ENERGY & AUTOMATION

More information