1 FM series position switches Selection diagram A A 0 A 0 External rubber gasket External rubber gasket External rubber gasket External rubber gasket 0 69 Round rod, stainless steel Square rod Glass fibre rod Porcelain roller WITH RESET 0-W 0-W 0-W 0-W -WR8 0-W -W -W ACTUATORS CONTACT BLOCKS slow action slow action slow action snap action snap action snap action slow action, make before break slow action and spaced slow action, 6 8 E NO+ NC +NC x() slow action slow action, slow action slow action slow action snap action independent close slow action, electronic, CONDUIT ENTRY Threaded conduit entry M Mx. (standard) PG. With cable gland K for cables Ø 6 mm K for cables Ø mm With M metal connector K0 8-pole, bottom K0 -pole, bottom product options Sold separately as accessory 6 General Catalogue Detection -8

2 A -R8 6 6 Roller Roller Roller Ø mm, Ø mm, Ø mm stainless steel stainless steel External rubber gasket Rope switch for signalling Adjustable lever Adjustable safety lever Without actuator SEPARATE ACTUATORS See page -W -W 6-W -W 8-W Without actuator Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options options FM 0-WGMK0RT6 Housing FM metal, one conduit entry, snap action 6, slow action, slow action, make before break Actuators 0 short plunger 0 roller lever 0 angled lever with roller Reset W W Contact type General Catalogue Detection -8 without reset (standard) simultaneous reset simultaneous reset, increased force silver contacts (standard) silver contacts, µm gold coating G (except contact block ) silver contacts,. µm gold coating (not for contact G block,,, ) Threaded conduit entry M Pre-installed cable glands or connectors no cable gland or connector (standard) K cable gland for cables Ø 6 mm K0 M metal connector, -pole For the complete list of possible combinations please contact our technical department. Mx. (standard) PG. Ambient temperature - C +80 C (standard) T6-0 C +80 C Rollers standard roller stainless steel Ø mm R8 (for actuators A, ) stainless steel Ø mm R (for actuators A, 0, A, 0, 0,,,,,, 6, ) stainless steel Ø mm R (for actuators 0,,,,,, 6, ) technopolymer, Ø mm R (for actuators 0,,,,,, 6, ) rubber, Ø 0 mm R (for actuators 0,,,,,, 6, ) rubber, Ø 0 mm R6 (for actuators,,,, 6, ) rubber, protruding, Ø 0 mm (for R actuators, 6) 68

3 FM series position switches Technical data Housing Metal housing, powder-coated One threaded conduit entry: Protection degree: Mx. (standard) IP6 acc. to EN 609 with cable gland presenting same or higher protection degree General data Ambient temperature: - C +80 C Max. actuation frequency: 600 operating cycles/hour Mechanical endurance: million operating cycles Mounting position: any Safety parameter B 0D : 0,000,000 for NC contacts Mechanical interlock, not coded: type acc. to EN ISO 9 Tightening torques for installation: see page Main features Metal housing, one conduit entry Protection degree IP6 contact blocks available actuators available Versions with M connector Versions with gold-plated silver contacts Quality marks: Cable cross section (flexible copper strands) s,,,, : min. x 0. mm ( x AWG ) max. x. mm ( x AWG 6) s, 6,, 9, 0,,,,,, 6, 8: min. x 0. mm ( x AWG ) max. x. mm ( x AWG ) : min. x 0. mm ( x AWG ) max. x. mm ( x AWG 6) In compliance with standards: IEC 609 -, EN 609 -, EN 609, EN 00, IEC 60, EN 60, EN ISO 9, EN ISO 00, IEC 609, EN 609, UL 08, CSA. No.. Approvals: IEC 609 -, UL 08, CSA. No., GB IMQ approval: EG609 UL approval: E8 CCC approval: EAC approval: RU C-IT.AД.В.00 Compliance with the requirements of: Low Voltage Directive //EU, EMC Directive /0/EU. Positive contact opening in conformity with standards: IEC 609 -, EN Installation for safety applications: Use only switches marked with the symbol next to the product code. Always connect the safety circuit to the NC contacts (normally closed contacts:, or -) as required by EN ISO 9, paragraph. for specific interlock applications and EN ISO 89 tables D (well-tried components) and D.8 (fault exclusions) for safety applications in general. Actuate the switch at least up to the positive opening travel shown in the travel diagrams on page 6. Actuate the switch at least with the positive opening force, reported in brackets below each article, next to the actuating force value. If not expressly indicated in this chapter, for correct installation and utilization of all articles see the instructions given on pages to. Electrical data without connector with M connector -pole Thermal current (I th 0 A Rated insulation voltage (U i 00 Vac 600 Vdc 00 Vac 00 Vdc (contact blocks,,,,,,, ) Rated impulse withstand voltage (U imp 6 kv kv (contact blocks,,,, ) Conditional short circuit current: 000 A acc. to EN 609 Protection against short circuits: type am fuse 0 A 00 V Pollution degree: Thermal current (I th A Rated insulation voltage (U i 0 Vac 00 Vdc Protection against short circuits: type gg fuse A 00 V Pollution degree: Utilization category Alternating current: AC (0 60 Hz) Ue (V) Ie (A) 6 Direct current: DC Ue (V) 0 Ie (A) Alternating current: AC (0 60 Hz) Ue (V) 0 Ie (A) Direct current: DC Ue (V) 0 Ie (A). 0. with M connector 8-pole Thermal current (I th A Rated insulation voltage (U i 0 Vac 6 Vdc Protection against short circuits: type gg fuse A 00 V Pollution degree: Alternating current: AC (0 60 Hz) Ue (V) Ie (A) Direct current: DC Ue (V) Ie (A) 69 General Catalogue Detection -8

4 Features approved by IMQ Rated insulation voltage (U i Conventional free air thermal current (I th Protection against short circuits: Rated impulse withstand voltage (U imp 6 kv kv 00 Vac 00 Vac (for contact blocks,,,,,,, ) 0 A type am fuse 0 A 00 V (for contact blocks,,,, ) Protection degree of the housing: IP6 MV terminals (screw terminals) Pollution degree: Utilization category: AC Operating voltage (U e 00 Vac (0 Hz) Operating current (I e A Forms of the contact element: Za, Zb, Za+Za, Y+Y, X+X, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact blocks, 6,, 9,,,, 6, 8,,,,, In compliance with standards: EN 609, EN A:09, fundamental requirements of the Low Voltage Directive //EU. Features approved by UL Utilization category Q00 (69 VA, 0 Vdc) A600 ( VA, 600 Vac) Housing features type, X,, For all contact blocks except and use 60 or C copper (Cu) conductors, rigid or flexible, wire size, AWG. Tightening torque for terminal screws of. lb in (0.8 Nm). For contact blocks and use 60 or C copper (Cu) conductors, rigid or flexible, wire size AWG. Tightening torque for terminal screws of lb in (. Nm). In compliance with standard: UL 08, CSA. No. Please contact our technical department for the list of approved products. Please contact our technical department for the list of approved products. Wiring diagram for M connectors +NO- NC M connector, M connector, M connector, M connector, M connector, M connector, M connector, M connector, M connector, 8-pole -pole -pole -pole -pole -pole -pole -pole -pole Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. NO NC NC NC NC NO NC NO NC ( ) NC 6 NO NO NO NC NO NC NO NC ( ) NC 8 ground ground ground ground ground ground ground ground NO 6 8 +NO NC NC+ NC+NO M connector, M connector, M connector, M connector, M connector, M connector, M connector, M connector, M connector, -pole -pole -pole -pole 8-pole 8-pole 8-pole -pole -pole Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. Contacts Pin no. NC ( ) NO ( ) NC, lever to the right - NC NC NC NC NC NC NC ( ) NO ( ) NC, lever to the left - NO NC 6 NC 6 NO 6 NO NC ground ground ground ground NO 8 NC 8 NO 8 ground ground ground ground ground E M connector, -pole Contacts Pin no. + - NC NO ground General Catalogue Detection -8 0

5 FM series position switches With stainless steel roller on request With stainless steel roller on request LO = slow action make before break LS = slow action LV = slow action and spaced LI = slow action independent LA = slow action close = electronic R LO 0 L R R LV LS LS 8 LA L L L R E.8. FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM -M FM 0-M FM 0-M FM 0-M FM 80-M FM 0-M FM 0-M FM -M FM -M FM E0-M Ø NO+ NC +NC x() page - type 8 N ( N ) page 6 - group FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM -M FM 0-M FM 0-M FM 0-M FM 80-M FM 0-M FM 0-M FM -M FM -M FM E0-M NO+ NC +NC x() page - type 6 N ( N ) page 6 - group FM A-M FM 6A-M FM A-M FM 9A-M FM 0A-M FM A-M FM A-M FM A-M FM A-M FM A-M FM 8A-M FM A-M FM A-M FM A-M FM A-M FM EA-M 0.8. NO+ NC +NC. x() page - type. N ( N ) page 6 - group FM A-M FM 6A-M FM A-M FM 9A-M FM 0A-M FM A-M FM A-M FM A-M FM A-M FM A-M FM 8A-M FM A-M NO+ FM A-M NC FM A-M +NC FM A-M x() FM EA-M page - type. N ( N ) page 6 - group With stainless steel roller on request With stainless steel roller on request.. (9 - ) ( - ). (9-) (-). R LO 0 L R R LV LS LS 8 LA L L L R E FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM -M FM 0-M FM 0-M FM 0-M FM 80-M FM 0-M FM 0-M FM -M FM -M FM E0-M NO+ NC +NC x() page - type 6 N ( N ) page 6 - group FM A-M FM 6A-M FM A-M FM 9A-M FM 0A-M FM A-M FM A-M FM A-M FM A-M FM A-M FM 8A-M FM A-M NO+ FM A-M NC FM A-M +NC FM A-M x() FM EA-M page - type. N ( N ) page 6 - group 06. FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM -M FM 0-M FM 0-M FM 0-M FM 80-M FM 0-M FM 0-M FM -M FM -M FM E0-M 0.8. NO+ NC +NC x() page - type N ( N ) page 6 - group FM A-M FM 6A-M FM A-M FM 9A-M FM 0A-M FM A-M FM A-M FM A-M FM A-M FM A-M FM 8A-M FM A-M NO+ FM A-M NC FM A-M +NC FM A-M x() FM EA-M page - type N ( N ) page 6 - group Items with code code on green on green background background are stock are items stock items Accessories See page 9 The D and D files are available at General Catalogue Detection -8

6 LO = slow action make before break LS = slow action LV = slow action and spaced LI = slow action independent LA = slow action close = electronic R LO 0 L R R LV LS LS 8 LA L L L R E FM 08-M FM 608-M FM 08-M FM 908-M FM 008-M FM 08-M FM 8-M FM 08-M FM 08-M FM 08-M FM 808-M FM 08-M FM 08-M FM 8-M FM 8-M FM E08-M Ø NO+ NC +NC x() page - type 8 N ( N ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M M8x. NO+ NC +NC Ø 8 x() page - type 8 N ( N ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M M 8x..8 NO+ NC +NC x() page - type 8 N ( N ) page 6 - group 8..9 FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M R 0.8. NO+ NC +NC x() page - type 8 N ( N ) page 6 - group Ø Ø R LO 0 L R R LV LS LS 8 LA L L L R E 0.8 FM -MR8 FM 6-MR8 FM -MR8 FM 9-MR8 FM 0-MR8 FM -MR8 FM -MR8 FM -MR8 FM -MR8 FM -MR8 FM 8-MR8 FM -MR8 FM -MR8 FM -MR8 FM -MR8 FM E-MR8. NO+ NC +NC x() page - type 8 N ( N ) page 6 - group FM 6-M FM 66-M FM 6-M FM 96-M FM 06-M FM 6-M FM 6-M FM 6-M FM 6-M FM 6-M FM 86-M FM 6-M FM 6-M FM 6-M FM 6-M FM E6-M 0.8. NO+ NC +NC x() page - type 8 N ( N ) page 6 - group FM -M FM 0-M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M 0.8. NO+ NC +NC x() m/s 0.0 Nm page 6 - group FM -M FM 0-M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M 0.8. NO+ NC +NC x() m/s 0.0 Nm page 6 - group Items with code code on green on green background background are stock are items stock items Accessories See page 9 The D and D files are available at General Catalogue Detection -8

7 FM series position switches With Ø mm stainless steel roller on request Other rollers available. See on page 8 Square rod, x mm LO = slow action make before break LS = slow action LV = slow action and spaced LI = slow action independent LA = slow action close = electronic R LO 0 L R R LV LS LS I 8 LA L L L R E 8. FM -M FM 0-M FM -M FM 8-M FM -M FM -M FM -M FM -M FM E-M 0.8. NO+ NC +NC Ø. x() m/s 0. Nm page 6 - group FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM 0-M FM 0-M FM 0-M FM 0-M FM 60-M FM 80-M FM 0-M FM 0-M FM 0-M FM 0-M FM E0-M NO+ NC +NC x() page - type 0.06 Nm (0. Nm ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M NO+ FM -M NC FM -M +NC FM -M x() FM E-M page - type 0.06 Nm (0. Nm ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M FM -M FM -M FM -M FM E-M xx. 8. NO+ NC +NC x(). m/s 0.06 Nm page 6 - group Round rod, Ø mm, stainless steel Other rollers available. See on page 8 Other rollers available. See on page 8 R LO 0 L R R LV LS LS I 8 LA L L L R E FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M FM -M FM -M FM -M FM E-M Ø NO+ NC +NC x(). m/s 0.06 Nm page 6 - group FM 0-M FM 60-M FM 0-M FM 90-M FM 00-M FM 0-M FM 0-M FM 0-M FM 0-M FM 0-M FM 60-M FM 80-M FM 0-M FM 0-M FM 0-M FM 0-M FM E0-M Øx. 8. NO+ NC +NC x(). m/s 0.06 Nm page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M FM -M FM -M FM -M FM E-M 8. NO+ NC +NC x() page - type 0.06 Nm (0. Nm ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M NO+ FM -M NC FM -M +NC FM -M x() FM E-M page - type 0.06 Nm (0. Nm ) page 6 - group Items with code code on green on green background background are stock are items stock items Accessories See page 9 The D and D files are available at General Catalogue Detection -8

8 Porcelain roller Other rollers available. See on page 8 Other rollers available. See on page 8 Other rollers available. See on page 8 LO = slow action make before break LS = slow action LV = slow action and spaced LI = slow action independent LA = slow action close = electronic R LO 0 L R R LV LS LS I 8 LA L L L R E Ø 9 FM -E0MV9 FM 6-E0MV9 FM -E0MV9 FM 9-E0MV9 FM 0-E0MV9 FM -E0MV9 FM -E0MV9 FM -E0MV9 FM -E0MV9 FM 8-E0MV9 FM -E0MV9 FM -E0MV9 FM -E0MV9 FM -E0M FM E-E0MV m/s 0.0 Nm (0. Nm ) page 6 - group FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M NO+ FM -M NC FM -M +NC FM -M x() FM -M FM E-M 8. NO+ NC +NC x() page - type 0.06 Nm (0. Nm ) page 6 - group FM -M () FM 6-M () FM -M () FM 9-M () FM 0-M FM -M () FM -M FM -M () FM -M () FM -M FM 6-M () FM 8-M () FM -M () NO+ FM -M () NC FM -M () +NC FM -M x() FM E-M page - type 0.06 Nm (0. Nm ) page 6 - group FM 6-M FM 66-M FM 6-M FM 96-M FM 06-M FM 6-M FM 6-M FM 6-M FM 6-M FM 6-M FM 66-M FM 86-M FM 6-M FM 6-M FM 6-M FM 6-M FM E6-M NO+ NC +NC x() page - type 0.06 Nm (0. Nm ) page 6 - group Other rollers available. See on page 8 Glass fibre rod Rope switch for signalling R LO 0 L R R LV LS LS I 8 LA L L L R E FM -M FM 6-M FM -M FM 9-M FM 0-M FM -M FM -M FM -M FM -M FM -M FM 6-M FM 8-M FM -M FM -M FM -M FM -M FM E-M NO+ NC +NC x() page - type 0.06 Nm (0. Nm ) page 6 - group () Positive opening only with actuator set to max. See page Ø6x FM 69-M FM 669-M FM 69-M FM 969-M FM 069-M FM 69-M FM 69-M FM 69-M FM 69-M FM 69-M FM 669-M FM 869-M FM 69-M NO+ FM 69-M NC FM 69-M +NC FM 69-M x() FM E69-M. m/s 0.06 Nm page 6 - group FM 6-M FM 66-M FM 6-M FM 96-M FM 06-M FM 6-M FM 6-M FM 6-M FM 6-M FM 6-M FM 86-M FM 6-M FM 6-M FM 6-M FM 6-M +NC NO NO+ x() 0. m/s initial N - final 0 N page 6 - group Accessories See page 9 The D and D files are available at General Catalogue Detection -8

9 FM series position switches with reset Pizzato Elettrica has developed a reset device code W to make perfectly simultaneous the actuator and the contact block tripping. This new device consists in a block to be mounted between the body and the head of the switch that can be rotated independently from the head. This new device offers the following advantages: The reset device can be integrated into almost all standard actuator heads s with snap action are no more necessary because the tripping movement is executed by the reset device itself The reset device can be rotated independently from the head ensuring maximum flexibility during installation Two actuating forces: standard and increased for vibration applications Mechanical endurance: million operating cycles. With stainless steel roller on request With stainless steel roller on request.. (9-) (-). Ø L L L L R FM 60-WM FM 90-WM FM 00-WM FM 0-WM FM 0-WM FM -WM FM -WM NO+ NC +NC + page - type. N ( N ) page - group 0.8 FM 60-WM FM 90-WM FM 00-WM FM 0-WM FM 0-WM FM -WM FM -WM. NO+ NC +NC + page - type N ( N ) page - group 0.8 FM 60-WM FM 90-WM FM 00-WM FM 0-WM FM 0-WM FM -WM FM -WM. NO+ NC +NC + page - type N ( N ) page - group 0.8 FM 60-WM FM 90-WM FM 00-WM FM 0-WM FM 0-WM FM -WM FM -WM. NO+ NC +NC + page - type. N ( N ) page - group With Ø mm stainless steel roller on request Other rollers available. See on page 8 Other rollers available. See on page L L L L R FM 6-WMR8 FM 9-WMR8 FM 0-WMR8 FM -WMR8 FM -WMR8 FM -WMR8 FM -WMR8.. NO+ NC page - type. N ( N ) page - group +NC FM 60-WM FM 90-WM FM 00-WM FM 0-WM FM 0-WM FM 0-WM FM 0-WM. NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group. 0.8 FM 6-WM FM 9-WM FM 0-WM FM -WM FM -WM FM -WM FM -WM. NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group FM 6-WM FM 9-WM FM 0-WM FM -WM FM -WM FM -WM FM -WM 9.. NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group Accessories See page 9 The D and D files are available at General Catalogue Detection -8

10 0 L L L L R Other rollers available. See on page 8 Other rollers available. See on page 8 Other rollers available. See on page 8 Other rollers available. See on page FM 6-WM FM 9-WM FM 0-WM FM -WM FM -WM FM -WM FM -WM NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group FM 6-WM FM 9-WM FM 0-WM FM -WM FM -WM FM -WM FM -WM 6.. NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group FM 66-WM FM 96-WM FM 06-WM FM 6-WM FM 6-WM FM 6-WM FM 6-WM NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group FM 6-WM FM 9-WM FM 0-WM FM -WM FM -WM FM -WM FM -WM.. 0. NO+ NC +NC + page - type 0.0 Nm (0. Nm ) page - group Increased actuating force The switch can be delivered with increased actuating force (option W). Ideal for vibration applications. Actuators 0,,, 6 N 0, 0 6 N 0. N Nm To order the switch with reset and increased actuating force, replace the -W option with -W in the order code. Example: FM 60-WM FM 60-WM Accessories See page 9 The D and D files are available at General Catalogue Detection -8 6

11 FM series position switches Position switches with swivelling lever without actuator LO = slow action make before break LS = slow action LV = slow action and spaced LI = slow action independent LA = slow action close = electronic R LO 0 L R R LV LS LS I 8 LA L L L R E M FM 8-M FM 68-M FM 8-M FM 98-M FM 08-M FM 8-M FM 8-M FM 8-M FM 8-M FM 8-M FM 68-M FM 88-M FM 8-M NO+ FM 8-M NC FM 8-M +NC FM 8-M x() FM E8-M 0.06 Nm (0. Nm ) page 6 - group With manual reset knob FM 68-WM FM 98-WM FM 08-WM FM 8-WM FM 8-WM FM 8-WM FM 8-WM NO+ NC +NC Nm (0. Nm ) page - group IMPORTANT For safety applications: join only switches and actuators marked with symbol next to the product code. For more information about safety applications see details on page. Separate actuators IMPORTANT: These separate actuators can be used only with items of the FR, FM, FX, FZ and FK series. Technopolymer roller Ø 8 mm Technopolymer roller Ø 8 mm Adjustable square rod, xx mm Flexible rod with pointed end Adjustable round rod Ø x mm Technopolymer roller Ø mm xx Ø6x0 0 M 9 Ø 9 M 80. M 0-9 M - 9 M 0 6. M. 9-6 M 06 Ø x. 9-6 M M 0 M M M.. VF LE0 VF LE VF LE VF LE VF LE0 VF LE Technopolymer roller Ø mm Porcelain roller Technopolymer roller Ø mm Adjustable actuator with technopolymer roller Adjustable safety actuator with technopolymer roller Technopolymer roller Ø mm Adjustable glass fibre rod M 9-89 VF LE VF LE () VF LE VF LE () VF LE6 VF LE VF LE69 - () Actuator VF LE can only be used in safety applications if adjusted to its max. length, as shown in the figure to the right. If an adjustable lever is required for safety applications, use the VF LE6 adjustable safety lever. - () The position switch obtained by assembling switch FM 8-M (e.g. FM 8 M, FM 68 M ) with actuator VF L will not present the same travel diagrams and actuating forces as switch FM E0MV9 (e.g. FM E0MV9, FM 6 E0MV9 ). - () The actuator cannot be rotated to the inside because it will hit the switch head upon actuation. 9 Items with code code on green on green background background are stock are items stock items Accessories See page 9 The D and D files are available at General Catalogue Detection -8

12 Special separate actuators IMPORTANT: These separate actuators can be used only with items of the FR, FM, FX, FZ and FK series. Stainless steel rollers, Ø mm VF LE-R VF LE-R VF LE-R VF LE-R VF LE-R VF LE6-R () VF LE-R Technopolymer rollers, Ø mm VF LE-R VF LE-R () VF LE-R 0. VF LE-R () ()... VF LE-R VF LE6-R () VF LE-R Rubber rollers, Ø 0 mm VF LE-R VF LE-R () VF LE-R () VF LE-R () VF LE-R VF LE6-R () VF LE-R () Rubber rollers, Ø 0 mm () VF LE-R6 () VF LE-R6 () 0 VF LE6-R VF LE-R6 () 0 6 VF LE-R VF LE-R6 () Protruding rubber rollers, Ø 0 mm VF LE-R Items with withcode code on green on green background background are stock areitems stock items General Catalogue Detection () VF LE6-R Accessories See page 9 The D and D files are available at 8

Safety switches with slotted hole lever

Safety switches with slotted hole lever Safety switches with slotted hole lever Selection diagram C1 C C C4 C5 Straight slotted hole lever Slotted hole lever at the left Slotted hole lever at the right (without bend) Slotted hole lever at the

More information

Position switches FM series

Position switches FM series B Position switches FM series Selection diagram 0 08 0 A A 0 A 0 external rubber gasket external rubber gasket external rubber gasket external rubber gasket 69 stainless steel round rod square rod fiber

More information

LR Position Switches TECHNICAL DATASHEET

LR Position Switches TECHNICAL DATASHEET TECHNICA DATASHEET Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 69 contact blocks available actuators available M assembled connector versions Silver

More information

Position switches FR series

Position switches FR series B Position switches FR series Selection diagram 0 A 0 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Siemens AG 29 Detecting Devices /2 Introduction 3SE5, 3SE2, 3SE3 Position Switches /4 General data /11 3SE5, plastic and metal enclosures /2 3SE2, plastic enclosures /26 3SE2, metal enclosures /36 3SE3,

More information

Subject to changes 11/2003 Page 1/7

Subject to changes 11/2003 Page 1/7 Main Characteristics: Zero switching. LED display. Various connection systems. Plug-in control terminal. Degree of protection IP 2. Double-insulated design. General Data: Standards / Approvals DIN EN 697--3

More information

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES

Contents. Han Hv ES / Han Hv E Technical characteristics Han Hv ES Technical characteristics Han Hv E Han 3 Hv ES Contents S / Page Technical characteristics S............................. 04.10 Technical characteristics.............................. 04.11 3 S.............................................. 04.12 3...............................................

More information

Control Stations ø 22

Control Stations ø 22 Control Stations ø 22 CONTROL STATIONS - NON-ILLUMINATED Technical Info (p. 103) MUSHROOM HEAD Ø 40 - MAINTAINED Push-turn to reset Part Number M16/20 47.9 25.7 Ø 40 Red NC EMERGENCY STOP LBX10510 Red

More information

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching Main Characteristics: Zero-point switching LED display Various connection technologies Plug-in control terminal Degree of protection IP 2 Insulated mounting foot Standards / Approvals: DIN EN 697--3 UL

More information

Type CP-S, CP-C & CP-A Switch mode

Type CP-S, CP-C & CP-A Switch mode Switch mode power CP-S, CP-C & CP-A Switch mode Characteristics CP-S and CP-C range Output current 5 A, 10 A and 20 A Integrated power reserve of up to 50 % 5 A and 10 A devices with pluggable connecting

More information

Complete units: Mushroom heads ø 22mm

Complete units: Mushroom heads ø 22mm Complete units: Mushroom heads ø 22mm MAINTAINED - NON-ILLUMINATED Ø 40 MUSHROOM Push-pull to reset Technical Info (p. 103) Black Bezel Part Number 34.2 Ø 40 Red NC L22DD01-3E01 Red 2 NC L22DD01-3E02 Red

More information

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X Characteristics Contactor type LC1 D09 D18 DT20 and DT25 Environment Rated insulation voltage (Ui) Conforming to IEC 097--1, overvoltage category III, degree of pollution: 3 Conforming to UL, CSA V 00

More information

Complete units: Push-buttons ø 22mm

Complete units: Push-buttons ø 22mm Complete units: Push-buttons ø 22mm FLUSH SPRING RETURN - NON-ILLUMINATED Chrome Bezel Part Number Technical Info (p. 103) Black Bezel Part Number 11 Ø 29.9 20.1 19.6 With single position clip Red NC L21AA01-1E01

More information

Complete units: Selector switches ø 22mm

Complete units: Selector switches ø 22mm Complete units: Selector switches ø 22mm SELECTOR SWITCHES - NON-ILLUMINATED Technical Info (p. 13) WITH KNOB 2 and 3 positions Chrome Bezel Part Number Black Bezel Part Number Ø 29.9 Maintained positions

More information

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration

Heavy-duty Metal Body Safety Interlock Switch. DIN mounting pattern for globally recognized mounting configuration C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1, EN50041 UL and C-UL listed T4011 Heavy-duty Metal Body Safety Interlock Switch Rugged enclosure the all metal housing and stainless steel actuator

More information

Electromechanical pressure and vacuum switches 0

Electromechanical pressure and vacuum switches 0 30350-EN_Ver6..fm/ Presentation Electromechanical and vacuum switches 0 Nautilus For control circuits, type XML Pressure and vacuum switches type XML are switches for control circuits. They are used to

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm ONE-PIECE PILOT LIGHTS Technical Info (p. 103) SUPPLIED WITHOUT BULB Part Number L20SA40 14.3 44.1 Ø 29.8 Ø 20.2 Ø 22 Ø 29.5 1 to 6 6 Ribbed Lens Clear Smooth Lens With text or symbol

More information

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21

Specifications Approval Type M12 A-coded HARAX M12-L HARAX M12 L 5 poles shielded M12 Crimp General data Electrical characteristics Materials 03 21 M12 A-coding Specifications IEC 60 352-4 Approval A-coding acc. to IEC 61 076-2-101 Circular Connectors Technical characteristics M12 A-coding Type M12 A-coded HARAX M12-L 5 poles HARAX M12 L shielded

More information

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M Characteristics Pendant control stations, for control circuits Environment Conforming to standards IEC 947-5-1, EN 60947-5-1 XAC-B : standard version : NEMKO, CSA 300 V type 4 Approvals XAC-M : standard

More information

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Product datasheet Characteristics LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC Price* : 107.62 GBP Main Range Product name Product or component type Device short name Contactor application Utilisation category

More information

Pendant control stations 6

Pendant control stations 6 Characteristics 6 Environment Conformity to standards IEC 97-5-1, EN 6097-5-1 Product certifications NEMKO. Special version: UL Listed A600-Q600, CSA A600-Q600 Protective treatment Standard version TH

More information

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009 Catalog 00 Contactors up to 5 A Motor Starters up to 55 kw 03/009 Kraus & Naimer The development of the Blue Line rotary switch, contactor and motor starter product ranges is based on more than hundred

More information

3 - Protection components Circuit-breakers

3 - Protection components Circuit-breakers Contents - Protection components Circuit-breakers for the motor protection Selection guide..............................................page /2 Thermal-magnetic motor circuit-breakers Selection guide..............................................page

More information

Separate units: Blocks

Separate units: Blocks Separate units: Blocks LED BLOCKS Technical Info (p. 103) SCREW TERMINALS Part Number 3.8 LED 19.7 20.1 X1 X2 33EARL 9.9 19.7 21.5 18.2 12/24 V White Red Green Blue Yellow 33EAWL 33EARL 33EAGL 33EABL 33EAYL

More information

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Electromechanical Safety Switches GSS Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION MICRO SWITCH Electromechanical Safety Switches GSS Series DESCRIPTION Honeywell s MICRO SWITCH GSS Series electromechanical safety switches are comprised of different groups of safety switches designed

More information

Operator Heads: ø 22mm

Operator Heads: ø 22mm Operator Heads: ø 22mm SPRING RETURN - NON-ILLUMINATED Technical Info (p. 103) FLUSH-FLUSH Twin touch Chrome Bezel Part Number Black Bezel Part Number 12.3 11 53.9 29.9 With International Symbols Green

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C),

More information

Datasheet - ZQ N

Datasheet - ZQ N 20.07.2016-17:41:15h Datasheet - ZQ 900-13N Pull-wire emergency stop switches / ZQ 900 Preferred typ Metal enclosure one-side operation / wire up to 75 m long Release push button Position indicator Robust

More information

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PFS Data sheet Three-phase monitoring relay CM-PFS The CM-PFS is a three-phase monitoring relay that is used to monitor three phase mains for incorrect phase sequence and phase failure. All devices are available

More information

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION MICRO SWITCH Key-Operated Safety Interlock Switch GK Series DESCRIPTION MICRO SWITCH GK Series switches are key-operated safety interlock rugged metal switches which monitor the positions of gates, guards,

More information

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts

Technical data. Contact material: with double break or 2 NC contacts Switching system: A IEC snap action with positive break NC contacts Emergency pull-wire switches ZS 71... NA Technical data Contact variations * 63 mm for version 200 N pre-tensioning force To EN 418/IEC 60947-5-5 Metal enclosure 2 contacts Integrated emergency-stop button

More information

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts The CT-WBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions

More information

Datasheet - PROTECT-IE-02

Datasheet - PROTECT-IE-02 Print - Create PDF - Create EXCEL file 20.04.2011-18:28:57h Datasheet - PROTECT-IE-02 Input expander / PROTECT-IE Input expander Input for up to 4 sensors per interface e.g.: magnetic safety switches type

More information

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS

Modeion OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS OTHER ACCESSORIES OF MOULDED CASE CIRCUIT BREAKERS P Other accessories DELAY UNIT Type Product code Description Weight [kg] Package [pc] BZ-BX-X230-A 36696 enables to delay the undervoltage release tripping

More information

Characteristics 5 TeSys k contactors and reversing contactors

Characteristics 5 TeSys k contactors and reversing contactors 90 Characteristics contactors k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 424 Product certifications LCp and LPp K06 to

More information

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages The CM-EFS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil Product data sheet Characteristics LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Controls Contactors and Contactor Assemblies Special Applications

Controls Contactors and Contactor Assemblies Special Applications Controls Contactors and Contactor Assemblies Special Applications Price groups 1B, 1H /2 Introduction More information can be found on the Internet: see the opening information, page 13 - Contactors for

More information

Detecting Devices. 8/2 Introduction

Detecting Devices. 8/2 Introduction Detecting Devices /2 Introduction /4 General data / 3SE5, plastic enclosures /16 3SE2, plastic enclosures /22 3SE5, metal enclosures /30 3SE2, metal enclosures /39 3SE3, metal enclosures Compact design

More information

Control module CP-A CM

Control module CP-A CM 2CDC 271 002 F0t05 Features Pluggable onto redundancy unit CP A RU Threshold values adjustable (14 28 V) One relay output per monitored input / channel Approvals H UL 508, CAN/CSA C22.2 No.14 H UL 60950,

More information

New Products Catalogue 2009 Safety Relays ESR5

New Products Catalogue 2009 Safety Relays ESR5 www.moeller.net New Products Catalogue 2009 Safety Relays ESR5 u Description Functional safety on machines monitoring with safety relays ESR5 Emergency-stop circuits Monitoring of movable guards with guard

More information

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents The CM-SRS.M1 is an electronic current monitoring relay that monitors single-phase mains (DC or AC) for over- and undercurrent

More information

SERIESN50, COAXIAL CONNECTORS

SERIESN50, COAXIAL CONNECTORS SERIESN50, COAXIAL CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER N connectors are available with 50 and 75 impedance. The frequency range extends to 18 GHz, depending on the connector and cable type.

More information

Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700

Datasheet - ZQ Pull-wire emergency stop switches / ZQ 700 Datasheet - ZQ 700-02 Pull-wire emergency stop switches / ZQ 700 Preferred typ thermoplastic enclosure one-side operation / wire up to 10 m long Release push button Position indicator Large wiring compartment

More information

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts The CT-AHS.22 is an electronic timer from the CT-S range with OFF-delay and 10 time ranges. All electronic timers from the CT-S

More information

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous Contact expander module for increasing the number of available contacts Approvals Unit features Positive-guided relay outputs: 8 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous

More information

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC Data sheet Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC The CM-IWS.1 serves to monitor insulation resistance in accordance with IEC

More information

Components for safety applications

Components for safety applications Metal, turret head, types CS-A, CS-C and CS-E Double insulated, turret head, types CS-PA, CS-TA and CS-TE Presentation Metal, types CS-A, CS-C, CS-E Switches with or without locking of the actuator Pages

More information

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact Data sheet Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact The CT-TGD.12 is an electronic time relay with the function pulse generator. It is from the CT-D range. With their MDRC profile

More information

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages The CM-ESS.M is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel

More information

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A

SIRCO M UL98 Load break switches standards UL and CSA 30 to 100 A The solution for Load break switches > Power distribution. sircm_100_a_1_cat Rotary switch SIRCO M 3 x 100 A Strong points > Total integration. > Wide range of accessories. > Upgradeability. > Compliance

More information

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition

LC2D09BD. Main. Device short name. Utilisation category. Poles description Pole contact composition Product datasheet Characteristics Main Range Product name Product or component type Device short name Contactor application Utilisation category Device presentation Poles description Pole contact composition

More information

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 For single-phase AC/DC currents The CM-SRS.2 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil

LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 32 A - 48 V DC coil Product data sheet Characteristics LC1D32ED TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Power supply CP-D 24/4.2 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply Data sheet Power supply CP-D 24/4.2 Primary switch mode power supply The CP-D range of modular power supply units in MDRC design (modular DIN rail components) is ideally suited for installation in distribution

More information

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF ABB AF12-30-01-14 250-500V50/60HZ-DC Contactor General Information Extended Product Type Product ID AF12-30-01-14 1SBL157001R1401 EAN 3471523110441 Catalog Description Long Description AF12-30-01-14 250-500V50/60HZ-DC

More information

Data sheet. W-Series WDU 10

Data sheet. W-Series WDU 10 The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Data sheet. W-Series WDU 4 BL

Data sheet. W-Series WDU 4 BL The versatile and extensive range of products - from 0.05 mm² to 300 mm² - means that you have diverse options for your applications at your disposal. Hardened steel for mechanical strength and high-quality

More information

Three-phase monitoring relays CM-PFE and CM-PFE.2

Three-phase monitoring relays CM-PFE and CM-PFE.2 Data sheet Three-phase monitoring relays CM-PFE and CM-PFE.2 The CM-PFE is a three-phase monitoring relay that monitors the phase parameter phase sequence and phase failure in three-phase mains. 2CDC 251

More information

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay Series - General purpose relays - 0 A Features Plug-in mount 0 A General purpose relay.. & pole changeover contacts Cadmium Free contacts (preferred version) AC coils & DC coils UL Listed (certain relay/socket

More information

Liquid level monitoring relay CM-ENS.2x

Liquid level monitoring relay CM-ENS.2x Data sheet Liquid level monitoring relay CM-ENS.2x The CM-ENS.2x is served to regulate and control liquid levels and ratios of mixtures of conductive fluids. It can be used for overflow protection, dry

More information

NS..S contactor relays - with spring terminals AC operated

NS..S contactor relays - with spring terminals AC operated NS..S contactor relays - with spring terminals AC operated NSES 1SBC101015F00 Description NS..S contactor relays are used for switching auxiliary and control circuits. These contactor relays are designed

More information

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.1 For single-phase AC/DC currents The CM-SRS.1 is an electronic current monitoring relay that protects single-phase mains (DC or AC) from over- and undercurrent

More information

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages The CM-ESS.2 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

Electronic timer CT-TGD.22

Electronic timer CT-TGD.22 2CDC 251 097 F0t06 a Rotary switch for the preselection of the time range of the ON time b Potentiometer with direct reading scale for the fine adjustment of the ON time c Rotary switch for the preselection

More information

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A

SIRCO M UL 98 Load break switches standards UL and CSA from 30 to 100 A Load break switches standards UL and CSA The solution for Load break switches sircm_1_a_1_cat > Power distribution Strong points Function Rotary switch SRCO M 3 x 1 A SRCO M load break switches are compact

More information

Protection components

Protection components Multifunction protection relays LT-P Environment Conforming to standards IEC 947-4-1, IEC 34-11, IEC 755, VDE 010, VDE 00. &Ãmarking Meets the essential requirements of the Low Voltage equipment (LV) &

More information

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil

LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 24 V DC coil Product data sheet Characteristics LC1D12BD TeSys D contactor - 3P(3 NO) - AC-3 -

More information

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description Type: EASY719 AC RC Article No.: 274115 Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC Description 12 digital inputs 6 relay outputs LCD display Operating buttons Screw terminals

More information

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Status indication LED U: Supply voltage

More information

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MXS.22 is a multifunctional electronic timer from the CT-S range. It provides 5 timing functions, 2 times 10 time

More information

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units BETA Switching Transformers, Bells and Socket Outlets /2 Product overview /3 4AC3 0, 4AC3 1 bell transformers /5 4AC3 4... 4AC3 transformers for permanent loads /8 4AC2 4 power supply units / 7LQ2 2 bells

More information

Technical features table for miniature circuit-breakers SH 200 Series

Technical features table for miniature circuit-breakers SH 200 Series Technical features table for miniature circuit-breakers SH 00 Series Standards Poles Tripping characteristics I n A frequency f Hz insulation voltage U i acc. to IEC/EN 60664-1 V Overvoltage category Pollution

More information

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC

Notes: Note1: Efficiency is tested at nominal input and full load at +25 C ambient. Output Voltage 400VAC 320VAC 360VAC 400VAC 400VAC Features DIN-Rail 2 and 3-phase operation Input voltage range: 320 575VAC Output trim range: 22.5 29.5VDC High electrical strength; high reliability Permanent overload and short-circuit protection Parallel

More information

Solid State Relay, 1-phase

Solid State Relay, 1-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relay, 1-phase Short-Circuit Proof, heat sink integrated Main Characteristics: Standards / Approvals: CE C-Ti I Zero-point switching Short-circuit

More information

AT4 Position Switches Complete Units

AT4 Position Switches Complete Units 03/012 03/013 Complete Units Complete units, IP65 Contacts M = Make B = Break f = Safety function by positive opening of contacts to IEC/EN 60 947-5-1 Contact sequence Contact U Closed u Open Zw = Positive

More information

Electronic timer CT-SDD.22

Electronic timer CT-SDD.22 CDC 099 F0t0 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied W

More information

Electronic timer CT-SDS.22

Electronic timer CT-SDS.22 CDC 0 F0t07 Features Rated control supply voltage 8 V DC, 0 V AC Single function timer with star delta change over One device includes 7 time ranges (0.0 s 0 min) n/o contacts LEDs for status indication

More information

Three-phase monitoring relays

Three-phase monitoring relays 2CDC 251 046 F0t08 Features Monitoring of three-phase mains for phase sequence, phase failure, phase unbalance Threshold value for phase unbalance adjustable as absolute value Tripping delay can be adjusted

More information

Three-phase monitoring relay CM-PVE

Three-phase monitoring relay CM-PVE Data sheet Three-phase monitoring relay CM-PVE The three-phase monitoring relay CM-PVE monitors the phase parameter phase failure as well as over- and undervoltage in three-phase mains. 2CDC 251 006 S0012

More information

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) Data sheet Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection) The temperature monitoring relays CM-TCS monitor overtemperature,

More information

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13

Micro Contactors. Micro Contactor Relays 10. Micro Contactors 11. Micro Contactors With Solder Pins 12. Coil voltages 12. Micro Reversing Contactor 13 Micro Contactor Relays 10 Micro Contactors 11 Micro Contactors With Solder Pins 12 Coil voltages 12 Micro Reversing Contactor 13 Technical Data 14 Dimensions 18 D946E 9 Micro Contactor Relays 4-pole AC

More information

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02

HARAX. Contents Technical characteristics circular connector with HARAX rapid termination 50.02 Contents Page Technical characteristics circular connector with rapid termination 50.02 Circular connector M8/M12 with rapid termination... 50.05 Han M12 panel feed-through... 50.08 Han M12 pcb adapter...

More information

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A

Switched mode power supply for DIN rail mounting type SMP21 DC24V/10A Switched mode power supply for DIN rail mounting type SMP2 DC24V/0A Description Switched mode power supply for rail mounting, with independent change-over of input voltages (AC 5/20 V), integral passive

More information

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Data. General specifications. Rated operating distance s n 3 mm 0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99 ATEX 1479X Usable up

More information

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24...

V2IM10AL10 Art.Nr.: V2IM10AL10P Art.Nr.: Control element. Tripping delay. Function selector. Status indication 24... P AC/DC current monitoring Multifunction Supply voltage 24-240V DC or 110-240V AC 1 change-over contact Width 22,5 mm Control element Tripping delay Maximum threshold Minimum threshold Function selector

More information

Capacitor Switching Contactors

Capacitor Switching Contactors Capacitor Switching D385E51 Technical catalogues and news under: www.benedict.at Motor-Starter Mini- Overload Relays Capacitor Switching Motor-Starters Modular Circuit Breakers M4-32T... up to 32A M4-32R..

More information

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts Data sheet Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts The CT-MBS.22 is a multifunctional electronic timer from the CT-S range. It provides 10 timing functions and 10 time ranges.

More information

40 Series - Miniature P.C.B. Relays A

40 Series - Miniature P.C.B. Relays A ..4..4..4 40 Series - Miniature P.C.B. Relays 8-0 - 6 A - P.C.B. or plug-in mount - AC, DC, sensitive DC or single bistable coil versions available - 8 mm, 6 kv (./0 µs) between coil and contacts - Ambient

More information

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents Data sheet Current monitoring relays CM-SRS.2 for single-phase AC/DC currents For the monitoring of currents in single-phase AC/DC systems, ABB s CM range comprises a wide selection of powerful and compact

More information

Three-phase monitoring relay CM-PBE

Three-phase monitoring relay CM-PBE Data sheet Three-phase monitoring relay CM-PBE The three-phase monitoring relay CM-PBE monitors the phase parameter phase failure in three-phase mains. 2CDC 251 007 S0012 Characteristics Monitoring of

More information

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories 2CDC 251 042 F0t08 CM-PVS.31 Features Monitoring of three-phase mains for phase sequence (can be switched off), phase failure, over- and undervoltage Threshold values for over- and undervoltage are adjustable

More information

05/09/2012

05/09/2012 17.5 mm EMER8 Part number 88829198 Multifunction or mono-function Multi-range (7 ranges) Multi-voltage or single voltage Screw terminals LED status indicator (1 voltage present LED, 1 timer ON LED) Option

More information

Protection components

Protection components General Application LT3-Si thermistor protection units continuously monitor the temperature of the machines to be protected (motors, generators, etc.) by means of PTC thermistor probes embedded in the

More information

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA Contactor relay, 2N/O+2N/C, AC Part no. DILA-22(24V60HZ) Catalog No. 276390 Eaton Catalog No. XTRE10B22B6 Delivery program Product range DILA relays Application Contactor relays Description Basic devices

More information

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-50 Delivery program Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection Part no. PKZM4-50 Catalog No. 222355 Eaton Catalog No. XTPR050DC1NL EL-Nummer 0004355161 (Norway)

More information

Thermistor motor protection relays

Thermistor motor protection relays Thermistor motor protection relays Content Benefits and advantages... / 68 Selection table... / 68 Ordering details CM-MSE... / 69 CM-MSS... / 69 CM-MSN... / 7 PTC sensor C0... / 7 Technical data... /